underscreed sound insulation system ... -...

2
Made from recycled waste rubber tough puncture resistant underscreed resilient layer ‘easy fit’ self adhesive fold-line cut flanking strip Isoedge 6/260 self adhesive flanking sound insulation strip. Min. 300Kg/m 2 concrete floor Screed to suit* *including proprietary screeds 6mm Isorubber Base MF Ceiling Isosonic Ceiling Strip self adhesive ceiling perimeter seal strip TM Isorubber Base 6mm Isorubber Base- Isoedge- TM IsoEdge Thermal Economics Ltd Thermal House 8 Cardiff Road Luton Bedfordshire LU1 1PP Tel:01582 450814 Fax:01582 429305 E-mail:[email protected] Web:www.thermal-economics.co.uk Ideal solution for BREEAM projects, site test results consistently exceed building regulation requirements A dense, tough recycled rubber product Virtually no short or long term compression deterioration under load A high acoustic performance Can be used with the full range of screed and flanking cavity wall constructions is a purpose made flanking sound insulation strip that provides a robust solution for the difficult edge details. (see reverse for details) The Isosonic Basefloor system is an under screed acoustic insulation and ceiling treatment for pre-cast plank, in-situ concrete, steel composite and beam & block floors. Suitable for use in new- build and refurbishment applications. For further information and detailed installation manual contact Thermal Economics Technical Department on: 01582 544255 or visit www.thermal-economics.co.uk UNDERSCREED SOUND INSULATION SYSTEM FOR CONCRETE FLOORS

Upload: dinhhuong

Post on 06-Feb-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UNDERSCREED SOUND INSULATION SYSTEM ... - …thermal-economics.co.uk/.../1376482367IsosonicBasefloorBrochure.pdf · Made from recycled waste rubber tough puncture resistant underscreed

Made from recycledwaste rubber

tough puncture resistant underscreed resilient layer

‘easy fit’ self adhesive fold-line cut flanking strip

IIssooeeddggee 66//226600self adhesive flankingsound insulation strip.

Min. 300Kg/m2

concrete floor

Screed to suit*

*including proprietary screeds

66mmmm IIssoorruubbbbeerrBBaassee

MF Ceiling

IIssoossoonniicc CCeeiilliinnggSSttrriippself adhesive ceilingperimeter seal strip

TTMMIIssoorruubbbbeerrBBaassee

6mm Isorubber Base-Isoedge-

TTMM

IIssooEEddggee

Thermal Economics Ltd Thermal House 8 Cardiff Road Luton Bedfordshire LU1 1PP

Tel:01582 450814 Fax:01582 429305 E-mail:[email protected] Web:www.thermal-economics.co.uk

Ideal solution for BREEAMprojects, site test resultsconsistently exceed buildingregulation requirements

A dense, tough recycledrubber product

Virtually no short or long termcompression deteriorationunder load

A high acoustic performance

Can be used with the fullrange of screed and flankingcavity wall constructions

is a purpose made flankingsound insulation strip thatprovides a robust solution forthe difficult edge details.(see reverse for details)

The Isosonic Basefloor

system is an under

screed acoustic

insulation and ceiling

treatment for pre-cast

plank, in-situ concrete,

steel composite and

beam & block floors.

Suitable for use in new-

build and refurbishment

applications.

For further information and detailed installation manual

contact Thermal Economics Technical Department on:

01582 544255 or visit www.thermal-economics.co.uk

UNDERSCREED SOUND INSULATION SYSTEMFOR CONCRETE FLOORS

Page 2: UNDERSCREED SOUND INSULATION SYSTEM ... - …thermal-economics.co.uk/.../1376482367IsosonicBasefloorBrochure.pdf · Made from recycled waste rubber tough puncture resistant underscreed

Isorubber Base is a durable, thin but dense materialwhich unlike soft cellular polymer products undergoesvirtually no short or long term compression undernormal floor loads.

This provides assurance that the full initial acousticperformance is maintained throughout the life ofthe building.

6mm Isorubber Base

Density 600 kg/m3 +- 30 kg/m3 +

- 65 kg/m3

Reclaimed Polyurethane FoamPolyethylene Foam

Full installationinstructions areprovided by the‘Isosonic BasefloorInstallation Guide’on our website.

flanking insulation strip: engineered for the purpose

Faulty installation of the floorperimeter is the single biggestcause of sound test failures inscreeded floors.

Corners and pipe penetrationsrequire a skillful treatment forwhich a simple ‘monolithic’

turn up of the underscreedmat is inadequate.

Isoedge is a purpose madeperimeter insulation strip thatprovides an easy robustmethod for the treatment ofthese problematic details.

Please visit our website for the full range of Thermal and Sound Insulation products atwww.thermal-economics.co.uk

©Thermal Economics Ltd. Draft 7 (Issue 1) Apr 2013

6mm10mm 10mm

Self adhesive strip

Precut fold lines

Isoedge

Internal and external corners

Pipe penetration

TTMMIIssooEEddggee

Product Properties and Characteristics-IIssoorruubbbbeerr BBaassee ccoonnttaaiinnss oovveerr 9900%% rreeccyycclleedd rruubbbbeerr,,pprroovviiddiinngg ssuussttaaiinnaabbllee lloonngg tteerrmm ppeerrffoorrmmaannccee..

TTMMIIssoorruubbbbeerrBBaassee