FDNY Search dmpalarms UL Listed Digital Cellular Communication for Fire Alarm Control Panels DIGITAL CELLULAR FIRE COMMUNICATORS FEATURES • 463G/463C enhances system security that conforms with NFPA and UL requirements • Direct reporting to the DMP Central Station receiver, with no relaying of alarm signals • Fire Slave Input option of the XR100/XR500 with 463G/463C approved for any FACP • Modular solution means easily updated for newer technologies • Eight-path redundancy with multiple message delivery available • DMP Adaptive Technology™ switches communication paths while maintaining supervision if the current path becomes unavailable The 463G/463C, when installed with a DMP XR100/ XR100FC or XR500/XR500FC Panel, is UL approved as a primary (standalone) fire communicator with no backup, and is approved as a fire slave communicator, compatible with any FACP. The 463G/463C provides a dependable communications link between your alarm system panel and Central Station. • Compared to a dialup communication link, cellular can save significantly in annual telecommunication costs • UL Listed as the Primary Communicator and Fire Slave Input for the XR100/XR500 in Fire Applications under ANSI/UL 864 Commercial Fire (Meets NFPA 72) • Works on digital cellular data networks over a variety of carriers • XR100N/XR500N with the 463G/463C approved as primary communication by the New York Fire Department (FDNY) • 463G/463C uses power from panel with low current draw for long standby battery life • Can be equipped with local or remote antenna, offering more flexibility when installing • Ability to check signal strength indication at the keypad • Messaging features transmit alarms/alerts to users via SMS text messages, and allow users to remotely control their panel via text commands

Upload: vuquynh

Post on 09-Mar-2018

220 views

Category:

Documents


3 download

TRANSCRIPT

FDNY

Search dmpalarms

UL Listed Digital Cellular Communication for Fire Alarm Control Panels

Digital Cellular Fire CommuniCators Features• 463G/463CenhancessystemsecuritythatconformswithNFPAandULrequirements

• DirectreportingtotheDMPCentralStationreceiver,withnorelayingofalarmsignals

• FireSlaveInputoptionoftheXR100/XR500with463G/463CapprovedforanyFACP

•Modularsolutionmeanseasilyupdatedfornewertechnologies

• Eight-pathredundancywithmultiplemessagedeliveryavailable

• DMPAdaptiveTechnology™switchescommunicationpathswhilemaintainingsupervisionifthecurrentpathbecomesunavailable

The463G/463C,wheninstalledwithaDMPXR100/XR100FCorXR500/XR500FCPanel,isULapprovedasaprimary(standalone)firecommunicatorwithnobackup,andisapprovedasafireslavecommunicator,compatiblewithanyFACP.The463G/463CprovidesadependablecommunicationslinkbetweenyouralarmsystempanelandCentralStation.

• Comparedtoadialupcommunicationlink,cellularcansavesignificantlyinannualtelecommunicationcosts

• ULListedasthePrimaryCommunicatorandFireSlaveInputfortheXR100/XR500inFireApplicationsunderANSI/UL864CommercialFire(MeetsNFPA72)

•Worksondigitalcellulardatanetworksoveravarietyofcarriers

• XR100N/XR500Nwiththe463G/463CapprovedasprimarycommunicationbytheNewYorkFireDepartment(FDNY)

• 463G/463Cusespowerfrompanelwithlowcurrentdrawforlongstandbybatterylife

• Canbeequippedwithlocalorremoteantenna,offeringmoreflexibilitywheninstalling

• Abilitytochecksignalstrengthindicationatthekeypad•Messagingfeaturestransmitalarms/alertstousersviaSMStextmessages,andallowuserstoremotelycontroltheirpanelviatextcommands

Intrusion | Fire | Access | Network | Cellular

463G

Fully superviseDYou’re kept fully informed of systemstatus. The unit sends full reportingmessages including Zones, Areas,andUsers,withallnamesanddetailsincluded.Fullsupervisionensuresthatthe cellular communication path isintactandfunctional.

eigHt-patH reDunDanCy Feelmore secure with up to eightpaths of communication redundancy.Select fromTCP,UDP,RS232,GPRS,CDMA, Single LineDialer, Dual LineDialerwithmultiple IPnumbers, andmultiple telephone numbers. Youidentifyandconfigureyour redundantcommunicationlinksviaRemoteLink.

ADACT(digitalalarmcommunicatortransmitter)systemmaybeconfiguredas:• Path1TypeDDPrimaryandPath2TypeDDBackup

• Path1TypeDDPrimaryandPath2TypeCELLBackup

• Path1TypeDDPrimaryandPath2TypeNETBackup

ANETorCELLsystemmaybeconfiguredas:• Path1TypeNETPrimarywithnoBackup

• Path1TypeCELLPrimarywithnoBackup

• Path1TypeNETPrimaryandPath2TypeDDBackup

• Path1TypeNETPrimaryandPath2TypeCELLBackup

• Path1TypeCELLPrimaryandPath2TypeNETBackup

ul listeDInstall the DMP 463G/463C DigitalCellular Communicator in anXR100/XR500 Series panel to create a ULlisted, primary communication pathfor commercial fire installations. TheFire Slave Input option of the XR500hasalsobeenapprovedunderANSI/UL864(NFPA722007&2010),allowingittobeusedasaSlaveCommunicatorforanyFACP.

DireCt reportingThe digital cellular communicatorstransmit IPdatapacketsdirectlyfromthepanel’sprocessoroverthewirelessdata network. All of themessagesthat are capableof beingsent by thecontrol panel are received directlyby theDMPCentral Station receiver.There are no intermediary serversornetworkoperationcenters, andnoretransmission or reinterpretation oftheinformation.Directreportingmeansfasterresponse,withnoconcernsaboutsignalsnot beingproperly relayedorintermediate communication linksfailing.

aDD-on to Xr100/Xr500 panel The463G/463Cworksas aneasy-to-install XR100/XR500 expansion card,withplug-and-playeaseofinstallation.No extra programming is required.It provides full data delivery of DMPZones,Areas,andUsers,withallnamesanddetailsincluded.The remarkably compact 463G/463Cwon’t take up a lot of space in yourcommunicationscloset.Theunitdirectlyinstallsinthepanelexpansioncardslot,whichismountedinsideasturdyUL-listedmetalcabinet.Tamperprotectionisalsoavailableforaddedsecurity.

aDaptive teCHnology™ If theprimary communicationpath iscompromisedorbecomesunavailable,Adaptive Technology almost instantlyswitchestoadesignatedbackuppath.Wheremultiplebackupsareavailable,communications canbeprogrammedtoswitchtoanotherpathasnecessary.Thecheckinfrequencyandprogrammingforabackuppathadapttothecheckinprogramming of the primary path.When the primary path becomesavailable,normalcommunicationsarerestored.AdaptiveTechnologyprovidesadditionalconfidenceintheintegrityofyoursystem,whileprotectingyoufromunexpectedcellularservicecharges.

reDuCeD eQuipment neeDsWithothercellularbackupequipment,you need to purchase additionalenclosures,powersupplies,batteries,cabling, andconduit connections. The463G/463Creducesthenumberofpiecesof equipment you have to purchase.It comes ready tomount, reducingyour initial costsandsimplifyingbothinstallationandongoingoperation.

reDuCeD CommuniCation CostsAddingthecellularcommunicatortotheDMPXR100/XR500 fire alarm controlpanel can lower costs significantlycompared to dial-up connections.Fire systems typically require twodial-up lines that can be eliminatedand replacedwith a single cellularconnection.

antenna plaCementTheunitincludesbothlocalandremoteSMA(S-bandmultipleaccess)antennaconnections,givingyouaddedfreedomandflexibilityduringinstallation.

low Current DrainWith its extremely low current drainand long standby battery life, the463G/463Cwill continue to provide acommunications link for anextendedperiod of time, even during a powerfailure.Itdrawshalfthecurrentofothercomparableunits.

Intrusion | Fire | Access | Network | Cellular

SPEC SHEET

simple to install anD programConnectthe463Gor463Ctoyourpanel,attach the antenna and power, andinstallationiscomplete.Programmingthe 463G/463C is fast and simple,accomplishedwithinthepanelitself.After programming the 463G/463Ccellular communications path viaRemoteLink,youwillbepresentedwiththeActivateSIM/MEIDwindowtoactivateyour cellular plan. Once activated,the wireless backup connection isimmediately online protecting yourcommunications link. No separateprogrammingutilityisrequired.

seCureCom Cellular serviCesThe463GcomesstandardwithaSIM(SubscriberIdentityModule)cardreadyto useSecureComWirelessCellularService fromDMP.The463CdoesnotincludeaSIMCardandisactivatedwiththeMEIDnumber.Withthe463G/463CandSecureCom, youhaveaone-stopresourceforbothhardwareandcellularservice.

enHanCeD Fire proteCtionCompared to dial-up connections, adigital cellular communication linkprovidesgreater reliability, protectionfrom sabotage, and is less proneto being knocked out by weather.Unlikemobile cellular connections,the463G/463Ccreatesafixednetworkconnection thatminimizeshand-offsandthechancefordroppedconnections.Whentroubleconditionsoccur,theycanbemorequicklydiagnosedandoftencorrectedremotely.TheNFPA 72 code requires a test oftheentirecommunicationspatheveryfiveminutes. TheDMPModelXR100/XR500CommandProcessorPanelusedwithDMP 463G/463CDigital CellularCommunicatormeetsthisrequirementwhen check-in and fail time settingsareprogrammedforfiveminutes.Thenet result is ahigher level of systemreliabilityincomparisonwithtraditionalsystemsthatrelyonredundantphonelinesandthesubstantiallylessfrequent24-hoursupervisionreportsassociatedwiththatapproach.

upDateableIn addition to being able to changecellular carriers, you will also beready to take advantage of technicalimprovementsastheyoccur.Theunit’smodulararchitectureenablesseamlessupgrades as improved technologybecomesavailable.

mobile platFormsDMPmobile platforms provide youwiththetoolsyouneed tobuild strong connectionswithyourcustomers.• MyAccess™enablesendusers tomonitor andmanage their systemsremotelyfromanymobilephoneusingsimpleSMStexting.• The Virtual Keypad™App puts akeypadon theuser’sApple iPhone®,iPad™,orAndroidcompatibledevices.•TheePad™putsaMobileKeypadonanybrowserormobiledevice.Dealers can offer these much-appreciatedservicestotheircustomersand realize the benefits of additionalrecurringrevenue.

myaCCessYourcustomerscansendmanyofthemost commonsystemcommands totheirresidentialorcommercialsystemsviatextmessages.Theycanalsochoosetohavealertssent to themeachtimethere’s an arm/disarm, an alarm, orotherselectedevents.Alertscanbetransmittedbythepanelastextmessagestouptothreephones.UserscanalsouseMyAccesstointeractwithanyZ-WavedevicesprogrammedthroughtheirDMPpanel,enablingthemtocontrollights,thermostats,andmoreviatextcommands.

tHe virtual KeypaD appDealers can invite their customers tobegin using their APP to give themcontrol of their security system. TheVirtualKeypadallowsthemtoarmordisarm,andtocheckthestatusoftheircellularconnectedDMPsecuritysystemfromanywheretheyhavecellservice.TheycanalsoaccessanyZ-Wavehomecontrol devicesprogrammed throughtheirDMPpanelandDMPcameras.

epaDThistechnologydeliversthefullfunctionand feel of a traditional LCDkeypadconnectedtoanyDMPpanel.

UseanymodelofcellphoneforMessagingFeatures

© 2

012

Dig

ital M

onito

ring

Prod

ucts

, Inc

. |

LT-1

165

| 12/

12

Intrusion | Fire | Access | Network | Cellular 2500 North Partnership BoulevardSpringfield, Missouri 65803-8877

800.641.4282 | dmp.comMade in the USA

Digital Cellular Communicator

speCiFiCationsPrimaryPower 12VDCfrompanelCurrentDraw(463G) Standby 22mA

Alarm 45mACurrentDraw(463C) Standby 22mA

Alarm 22mA

CompatibilityDMPXR100/XR500SeriesusingSoftwareVersion202orhigher

orDering inFormation463G 2GDigitalCellularCommunicator(AT&T,T-Mobile, Rogers)

463C 3GCDMACellularCommunicator(Verizon)

aCCessories380-400 ReplacementLevel400SIMCard381-12 12'CoaxExtension381-25 25'CoaxExtension383 RubberDuckAntenna386 WallMountAntennaBracket387-1 3dBFiberglassAntennaw/bracket387-2 2dBAttackEnclosureAntenna

aCCessories Cont. 387-3 3dBMEGAntenna387-25 SMATONCABLE,25FT,LMR195387-50 SMATONCABLE,50FT,LMR195

listings anD approvals463G FCCID:MIVGSM0308IndustryCanada:4160A-GSM0308UnderwritersLaboratoriesCanada(ULC)Listed ULCSubject-C1023 HouseholdBurglar ULC/ORD-C1076 ProprietaryBurglar ULCS304 CentralStationBurglar ULCS545 HouseholdFire463C FCCID:MIVCNN0301IndustryCanada:4160A-CNN0301463G/463CCaliforniaStateFireMarshal(CSFM)NewYorkCity(FDNYCOA#6123)UnderwritersLaboratories(UL)Listed ANSI/UL365 PoliceStationConnectBurglarAlarmSystems ANSI/UL985 HouseholdFireWarningSystemUnits ANSI/UL1023 HouseholdBurglarAlarmSystemUnits ANSI/UL1076 ProprietaryBurglarAlarmUnits&Systems ANSI/UL1610 CentralStationBurglarAlarmUnits ANSI/UL864 ControlUnitsforFire-ProtectiveSignalingSystems

two-way CommuniCation Superior to tradit ional wirelessdevices that just broadcast until thezone is restored, DMP 1100 Seriesrequire an acknowledgement fromthe 1100 Series Receiver, indicatingsuccessfulcommunication.Thissmarttechnology ensures that each andevery communication is receivedandefficiently processed at the panel.With the 900MHz frequency-hoppingspread-spectrum technology, clearand accurate signal transmissionswithout interference inpracticallyanyenvironmentistobeexpected.

1100 series reCeivers The1100SeriesReceivers:1100Xand

1100XHallowyoutoaddup to 500 transmittersand is required forwireless capability inboth regularandharshenvironments.

1103 universal transmitter Model 1103Universal Transmitter istypically used in commercial fire orburglarydoor/windowapplications.Itoffers thesame lookand featuresasthe1101transmitter,withtheadditionofa470kend-of-lineresistorandwalltamperswitch.

1165/1165H/1165Hs CommerCial smoKe DeteCtors TheModel1165SmokeDetector,1165HSmoke/Heat Detector, and 1165HS

Smoke/HeatDetectorwith Sounder includea tamper switch thatsendsatroublesignalifthedetectorisremovedfrom the mountingbase.

1181 post inDiCator valve Themodel1181PIVisaweatherproofand tamper resistantwireless switchformonitoringtheopenpositionoffiresprinkler control values of the postindicator,butterflyandothertypes.

1182 os&y The1182OS&YSwitchisusedtomonitortheopenpositionof anOS&Y (OutsideScrewand Yoke) type gate valve. The1182mountsconvenientlytomostOS&Yvalvesranginginsizefrom½”to12”.Theswitchoperatestheexternalcontactsofthewirelesstransmitterwhenthevalvepositionisalteredfromanopenstate.

Dmp wireless DeviCes For ansi/ul 864 CommerCial FireCompleteyourfiresystemwithotherDMPwirelessdevicesthatareANSI/UL864ListedforFireProtectiveSignalingSystems.