Sensing and Control Issue 2 81501 m WARNING IMPROPER INSTALLATION Consult with local safety agencies and their requirements when designing a machine-control link, interface, and all control elements that affect safety. Strictly adhere to all installation instructions. Failure to comply with these instructions could result in death or serious injury. MOUNT, WIRE, AND SEAL THE SWITCH m WARNING IMPROPER OPERATION Ensure switch actuator achieves sufficient travel for positive opening of normally closed (NC) contacts to occur. Failure to comply with these instructions could result in death or serious injury. 1. Refer to: Page 3 for adjustments. Pages 8 to 17 for specific travel distances for each switch code, and specifications. Page 4 proper application of limit switches, and switch mounting dimensions. 2. Perform adjustments (if desired): Head orientation, page 4. Actuation direction (Figure 2, page 4). Side rotary switches with 90* positive drive levers (cata- log listings ending in A1A, A1B, A5A, A5B) (Figure 3): - Ensure flats of switch shaft engage groove in actuator lever. - Tighten locking screw (A) until tab (B) no longer moves. 3. Mount switch using four M5 or #10 screws. Torque screws to 4,9 Nm to 5,9 Nm [43 in-lb to 52 in-lb]. 4. Remove screws on cover plate. 5. Connect stranded wire (0,75 mm 2 to 2,5 mm 2 , 18-14 AWG) or solid wire (0,75 mm 2 to 1,5 mm 2 , 18-16 AWG) to connector terminals (use 90 *C wire when ambient temperature is over 75 *C). Torque switch terminal screws to 0,8 Nm to 1,0 Nm [7 in-lb to 9 in-lb]. 6. Seal conduit opening according to instructions in PK 80112. 7. Reassemble cover plate, and torque cover screws to 0,5 Nm [4.4 in-lb]. Installation Instructions for the MICRO SWITCH™ Global Limit Switches (GLS-DIN Series) Instrucciones de instalación para los MICRO SWITCH™ interruptores limite global (serie GLS-DIN) Einbauanweisungen für den MICRO SWITCH™ Global Endschalter (Serie GLS-DIN) Instructions d’installation du MICRO SWITCH™ fin de course mondiales (série GLS-DIN) Istruzioni per l’installazione del MICRO SWITCH™ finecorsa globali (Serie GLS-DIN) Instruções de Instalação para o MICRO SWITCH™ de limite global (Série GLS-DIN) Ui 600V ac Ui 300V dc UL 50041 EN60947-5-1 m ADVERTENCIA INSTALACIÓN INCORRECTA Consulte las normas de seguridad y sus requisitos al realizar el diseño del enlace de control de una máquina, la interfaz, y los elementos de control que afecten a la seguridad. Siga estrictamente todas las instrucciones para la instalación. El incumplimiento de estas recomendaciones puede ocasionar lesiones graves o peligro de muerte. MONTAJE, CABLEADO Y SELLADO DEL IN- TERRUPTOR m ADVERTENCIA FUNCIONAMIENTO INCORRECTO Asegúrese que el actuador del interruptor tenga la suficiente carrera para que se produzca la apertura positiva de los contactos normalmente cerrados (NC).. El incumplimiento de estas recomendaciones puede ocasionar lesiones graves o peligro de muerte. 1. Consulte: la página 3 para los ajustes las páginas 8 y 17 para las distancias de carrera espe- cíficas de cada código de interruptor y las especifica- ciones. la página 4 para la correcta aplicación de los interrup- tores final de carrera y las dimensiones de montaje del interruptor. 2. Realice ajustes (si lo desea): Orientación del cabezal (la página 4). Dirección del accionamiento (véase la figura 2, la pá- gina 4). Interruptores de rotación lateral con palancas de impul- sión positiva de 90º (las referencias del catálogo que terminen en A1A, A1B, A5A, A5B) (véase la figura 3): - Asegúrese de que las caras del eje del interruptor enganchen la ranura de la palanca del actuador. - Ajuste el tornillo de apriete (A) hasta que la lengüeta (B) deje de moverse. 3. Para montar el interruptor, utilice cuatro tornillos M5 o del número 10. Ajuste los tornillos hasta 4,9 Nm a 5,9 Nm (43 a 52 pulg. lb). 4. Quite los tornillos de la tapa. 5. Conecte cable trenzado (0,75 mm 2 a 2,5 mm 2 , 18-14 AWG) o cable sólido (0,75 mm 2 a 1,5 mm 2 , 18-16 AWG) a los terminales del conector (utilice cable de 90 *C cuando la temperatura ambiente supere los 75 *C). Ajuste los tornillos de los terminales hasta 0,8-1,0 N m (7-9 pulg. lb).

Upload: others

Post on 13-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

Sensing and Control

Issue 2

81501

m WARNINGIMPROPER INSTALLATION• Consultwithlocalsafetyagenciesandtheirrequirements

whendesigningamachine-controllink,interface,andallcontrolelementsthataffectsafety.

• Strictlyadheretoallinstallationinstructions.Failure to comply with these instructions could result in death or serious injury.

MOUNT, WIRE, AND SEAL THE SWITCH

m WARNINGIMPROPER OPERATION• Ensureswitchactuatorachievessufficienttravelfor

positiveopeningofnormallyclosed(NC)contactstooccur.

Failure to comply with these instructions could result in death or serious injury.

1. Referto:• Page3foradjustments.• Pages8to17forspecifictraveldistancesforeach

switchcode,andspecifications.• Page4properapplicationoflimitswitches,andswitch

mountingdimensions.2. Performadjustments(ifdesired):

• Headorientation,page4.• Actuationdirection(Figure2,page4).• Siderotaryswitcheswith90*positivedrivelevers(cata-

loglistingsendinginA1A,A1B,A5A,A5B)(Figure3): -Ensureflatsofswitchshaftengagegrooveinactuator

lever. -Tightenlockingscrew(A)untiltab(B)nolonger

moves.3. MountswitchusingfourM5or#10screws.Torquescrewsto

4,9Nmto5,9Nm[43in-lbto52in-lb].4. Removescrewsoncoverplate.5. Connectstrandedwire(0,75mm2to2,5mm2,18-14AWG)

orsolidwire(0,75mm2to1,5mm2,18-16AWG)toconnectorterminals(use90*Cwirewhenambienttemperatureisover75*C).Torqueswitchterminalscrewsto0,8Nmto1,0Nm[7in-lbto9in-lb].

6. SealconduitopeningaccordingtoinstructionsinPK80112.7. Reassemblecoverplate,andtorquecoverscrewsto0,5Nm

[4.4in-lb].

Installation Instructions for the MICRO SWITCH™ Global Limit Switches (GLS-DIN Series)Instrucciones de instalación para los MICRO SWITCH™ interruptores limite global (serie GLS-DIN)Einbauanweisungen für den MICRO SWITCH™ Global Endschalter (Serie GLS-DIN)Instructions d’installation du MICRO SWITCH™ fin de course mondiales (série GLS-DIN)Istruzioni per l’installazione del MICRO SWITCH™ finecorsa globali (Serie GLS-DIN)Instruções de Instalação para o MICRO SWITCH™ de limite global (Série GLS-DIN)

Ui 600V acUi 300V dcUL 50041EN60947-5-1

m ADVERTENCIAINSTALACIÓN INCORRECTA• Consultelasnormasdeseguridadysusrequisitosalrealizar

eldiseñodelenlacedecontroldeunamáquina,lainterfaz,yloselementosdecontrolqueafectenalaseguridad.

• Sigaestrictamentetodaslasinstruccionesparalainstalación.

El incumplimiento de estas recomendaciones puede ocasionar lesiones graves o peligro de muerte.

MONTAJE, CABLEADO Y SELLADO DEL IN-TERRUPTOR

m ADVERTENCIAFUNCIONAMIENTO INCORRECTO• Asegúresequeelactuadordelinterruptortengalasuficiente

carreraparaqueseproduzcalaaperturapositivadeloscontactosnormalmentecerrados(NC)..

El incumplimiento de estas recomendaciones puede ocasionar lesiones graves o peligro de muerte.

1. Consulte:• lapágina3paralosajustes• laspáginas8y17paralasdistanciasdecarreraespe-

cíficasdecadacódigodeinterruptorylasespecifica-ciones.

• lapágina4paralacorrectaaplicacióndelosinterrup-toresfinaldecarreraylasdimensionesdemontajedelinterruptor.

2. Realiceajustes(silodesea):• Orientacióndelcabezal(lapágina4).• Direccióndelaccionamiento(véaselafigura2,lapá-

gina4).• Interruptoresderotaciónlateralconpalancasdeimpul-

siónpositivade90º(lasreferenciasdelcatálogoqueterminenenA1A,A1B,A5A,A5B)(véaselafigura3):

-Asegúresedequelascarasdelejedelinterruptorenganchenlaranuradelapalancadelactuador.

-Ajusteeltornillodeapriete(A)hastaquelalengüeta(B)dejedemoverse.

3. Paramontarelinterruptor,utilicecuatrotornillosM5odelnúmero10.Ajustelostornilloshasta4,9Nma5,9Nm(43a52pulg.lb).

4. Quitelostornillosdelatapa.5. Conectecabletrenzado(0,75mm2a2,5mm2,18-14AWG)

ocablesólido(0,75mm2a1,5mm2,18-16AWG)alosterminalesdelconector(utilicecablede90*Ccuandolatemperaturaambientesuperelos75*C).Ajustelostornillosdelosterminaleshasta0,8-1,0Nm(7-9pulg.lb).

Page 2: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

2 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

6. SelleelconductodeentradasegúnlasinstruccionesenPK80112.

7. Vuelvaamontarlatapa,yconunallavedetorsión,ajustelostornillosa0,5Nm(4.4inlbf).

m WARNUNGUNSACHGEMÄSSER EINBAU• BeratenSiesichmitdenzuständigenSicherheitsbehörden

beimEntwurfvonVerbindungenzuMaschinensteuerungen,SchnittstellenundsämtlichenSteuerelementen,welchedieSicherheitbetreffen.

• HaltenSiesichgenauandieEinbau-Anweisungen.Das Nichtbeachten dieser Anweisungen könnte zum Tod oder zu schweren Verletzungen führen.

SCHALTER MONTIEREN, ANSCHLIESSEN UND ABDICHTEN

m WARNUNGUNSACHGEMÄSSER BETRIEB• Sicherstellen,daßderBetätigergenügendLaufweghat,um

dieÖffnerkontakte(NC)zwangszuöffnen.Das Nichtbeachten dieser Anweisungen könnte zum Tod oder zu schweren Verletzungen führen.

1. WeitereInformationen:• EinstellungenaufSeite3.• SpezifischeLaufwegefürjedenSchaltercodeundtech-

nischeDatenaufSeite8und17.• OrdnungsgemäßeAnwendungvonPositionsschaltern

undAbmessungenfürdieSchaltermontageaufSeite4.2. Einstellungenvornehmen(fallsgewünscht):

• AusrichtungdesKopfes(aufSeite4).• Betätigungsrichtung(Abbildung2,aufSeite4).• SchaltermitseitlichemSchwenkhebelmit90°-Zwangss-

teuerhebeln(BestellnummernendenmitA1A,A1B,A5A,A5B)(Abbildung3):

-Sicherstellen,daßdiegegenüberliegendenFlächendesSchalterschaftsindieRilleimBetätigerhebeleing-reifen.

-DieSicherungsschraube(A)anziehen,bisdieNase(B)nichtmehrzubewegenist.

3. DenSchaltermitHilfevonvierM5-SchraubenoderSchraubenNr.10montieren.Schraubenmit4,9...1,80Nmanziehen.

4. DieSchraubenaufderDeckplatteentfernen.5. DenLitzendraht(0,75mm2…2,5mm2,18…14AWG)oder

Draht(0,75mm2…1,5mm2,18…16AWG)andieKlem-mleistenanschließen(90°C-Drahtverwenden,wenndieUmgebungstemperaturüber75°Cliegt).DieKlemmleisten-schraubendesSchaltersmit0,8...1,0Nmanziehen.

6. DieKabeleinführungentsprechenddenAnweisungeninPK80112abdichten.

7. AbdeckungwiederanbringenundAbdeckschraubenmiteinemDrehmomentvon0.5Nmanziehen.

m AVERTISSEMENTINSTALLATION INCORRECTE• Faitesappelàdesemperatulocauxdesécuritéetprenez

encompteleursexigenceslorsquevousconcevezuneliaisondecommandeouinterfacedemachine,outoutautredispositifdecommandemettantenjeulasécurité.

• Respectezscrupuleusementl’ensembledesinstructionsd’installation.

L’inobservation de ces instructions peut entraîner la mort ou de graves blessures.

MONTEZ, CABLEZ ET ETANCHEIFIEZ L’INTERRUPTEUR

m AVERTISSEMENTMAUVAIS FONCTIONNEMENT• Veillezàcequel’actionneurdel’interrupteurparcourtune

coursesuffisanteafindepermettreuneouverturepositivedescontactsnormalementfermés(NF).

L’inobservation de ces instructions peut entraîner la mort ou de graves blessures.

1. Consultez:• Lapage3pourlesréglages.• Lespages8et17pourconnaîtreleslongueursde

coursespourchaquecoded’interrupteuretlescaracté-ristiquestechniques.

• Lapage4poursavoircommentréaliseruneapplicationcorrectedesinterrupteursdefindecourseetconnaîtrelescotesdemontagedel’interrupteur.

2. Effectuezlesréglages(lecaséchéant):• Orientationdelatête(lapage4).• Sensd’actionnement(figure2,lapage4).• Interrupteursàrotationlatéraleavecleviersà90*à

actionpositive(numérosdeemperatuseterminantparA1A,A1B,A5A,A5B)(figure3):

-Veillezàcequelesméplatsdel’axedel’interrupteurs’engagentdansl’encochedulevierdel’actionneur.

-Serrezlavisdeblocage(A)jusqu’àcequelalanguette(B)nebougeplus.

3. Montezl’interrupteuràl’aidedevisM5oun°10.Serrezlesvisavecuncouplede4,9à5,9N.m(43à52in.lb).

4. Retirezlesvisducouvercle.5. Connectezdufilsouple(0,75mm2à2,5mm2,18à14AWG)

ourigide(0,75mm2à1,5mm2,18à16AWG)auxbornesduconnecteur(utilisezdufil90*Clorsquelaemperatuream-bianteestsupérieureà75*C).Serrezlesvisdesbornesdel’interrupteuravecuncouplede0,8à1,0N.m(7à9in.lb).

6. Réalisezl’étanchéitédel’ouvertureduconduitconformé-mentauxinstructionsdonnéesenPK80112.

7. Remonterlecouvercle,etserrezlesvisducouvercleavecuncouplede0,5N.m(4.4in.lb).

Page 3: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl3

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

m ATTENZIONEINSTALLAZIONE SCORRETTA• Consultareglientilocaliinmateriadiantinfortunistica

elerispettivenormativenelmomentoincuicisiavviaallaprogettazionediunqualsiasicollegamentocontrollomacchina,odiun’interfaccia,odituttiglielementidicontrollochepossanoinfluiresullasicurezza.

• Attenersirigorosamenteatutteleistruzionirelativeall’installazione.

L’inosservanza di tali istruzioni può essere causa di gravi lesioni, con conseguenze addirittura fatali.

MONTARE, CABLARE E SIGILLARE L’INTERRUTTORE

m ATTENZIONEFUNZIONAMENTO SCORRETTO• Accertarsichelacorsadell’attuatoredell’interruttoresia

sufficienteaconsentirel’aperturaforzatadeicontattinormalmentechiusi(NC).

L’inosservanza di tali istruzioni può essere causa di gravi lesioni, con conseguenze addirittura fatali.

1. Fareriferimentoa:• Pagina3,perleregolazioni.• Pagina8epagina17,perglispecificivalorirelativia

ciascuncodicediinterruttoreeperidatitecnici.• Pagina4,perilcorrettoimpiegodegliinterruttorifine-

corsaeperledimensionidimontaggio.2. Eventualmenteeseguireleregolazioni(inbasealleesigen-

ze):• Orientamentotesta(Pagina4).• Direzionediattuazione(Figura2,pagina4).• Interruttoriarotazionelateraleconleveadazionamento

meccanicoa90°(vocidicatalogochefinisconoconA1A,A1B,A5A,A5B)(Figura3);

-Accertarsichelealettedell’alberinodell’interruttoresianoinseritenell’appositascanalaturadellalevadell’attuatore.

-Serrarelavitedifermo(A)finchéilmovimentodellalinguetta(B)nonrisultaimpedito.

3. Montarel’interruttoremediantequattrovitiM5o#10.Serrarelevitiadunacoppiaparia4,9-5,9Nm[43-52poll.lb.].

4. Rimuoverelevitidallapiastradicopertura.5. Collegarecaviflessibili(0,75mm2-2,5mm2,18-14AWG)

ocavirigidi(0,75mm2-1,5mm2,18-16AWG)aimorsettideiconnettori(selatemperaturaambientesuperai75°C,utilizzarecavichehannounatemperaturadiesercizioparia90°C).Serrarelevitiadunacoppiaparia0,8-1,0Nm[7-9poll.lb.].

6. Sigillarel’aperturadeltuboisolanteinbasealleistruzionidellaPK80112.

7. Rimontareilcoperchio,estringerelevitifinoalmassimodi0,5Nm.[4.4in-lb].

m ADVERTÊNCIAINSTALAÇÃO INCORRETA• Consulteasagênciasdesegurançalocaleseusrequisitos

aoprojetarunidadesdeconexãoouinterfaceparacontroledemáquinas,bemcomotodososelementosdecontrolequepossamafetarasegurança

• Obedeçarigorosamentetodasasinstruçõesdesegurança.Desobediência a essas instruções pode resultar em morte ou ferimentos graves.

MONTAGEM, FIAÇÃO E VEDAÇÃO DO SWITCH

m ADVERTÊNCIAINSTALAÇÃO INCORRETA• Certifique-sedequeoatuadordoswitchatinjaumpercurso

suficienteparaqueocorraaaberturapositivadecontatosnormalmentefechados(NC,normallyclosed).

Desobediência a essas instruções pode resultar em morte ou ferimentos graves.

1. Consulte:• Apágina3paraajustes.• Aspáginas8e17parasaberasdistânciasdepercurso

específicasparacadacódigodeswitcheespecifica-ções.

• Apágina4paraveraaplicaçãoadequadadeswitchesdefimdecursoedimensõesdemontagemdosswitch-es.

2. Façaosajustesnecessários(sedesejado):• Orientaçãodacabeça(Apágina4).• Direçãodeatuação(Figura2,apágina4).• Switchescomacionamentolateralcomalavancasde

direçãode90°positivos(listasdocatálogocomtermi-naçãoA1A,A1B,A5A,A5B)(Figura3):

-Certifique-sedequeosplanosdoeixodoswitchencaixem-senossulcosdaalavancadoatuador.

-Aperteoparafusodetrava(A)atéquealingüeta(B)nãosedesloquemais.

3. MonteoswitchusandoquatroparafusosM5ounº10.Aperteosparafusoscomumtorquede4,9-5,9N-m(109,22-132,08cmlb).

4. Removaosparafusosdatampadecobertura.5. Conectecabostrançados(0,75mm2-2,5mm2,18-14

AWG)ousólidos(0,75mm2to1,5mm2,18-16AWG)aosterminaisdoconector(utilizecabospara90°Cquandoatemperaturaambientepassardos75°C).Aperteospara-fusosdoterminaldoswitchcomumtorquede0,8-1,0N-m(17,78-22,86cm-lb).

6. SeleaaberturadoconduítedeacordocomasinstruçõesdescritasemPK80112.

7. Remontarpratodecobertura,eparafusosdecoberturadetorquepara0,5Nm(4.4pol/lb).

Page 4: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

4 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

ContactClosed Contactocerrado Kontaktgeschlossen Contactfermé Contattochiuso ContatoFechado

ContactOpen Contactoabierto Kontaktoffen Contactouvert Contatto aperto ContatoAberto

DifferentialTravel Carreradiferencial Differenzwinkel Coursedifférentielle Corsadifferenziale PercursoDiferencial

FreePosition Posiciónlibre Freistellung Positionlibre Posizionelibera PosiçãoLivre

OperatingPosition1 Posicióndefunciona-miento1

Schaltpunkt1 Positiondecommuta-tion 1

Posizionedifunzion-amento1

PosiçãodeOpera-ção1

PositiveOpening1toIEC947-5-1

Aperturapositiva1segúnIEC947-5-1

Zwangsöffnung1gemäßIEC947-5-1

Ouverturepositive1selonCEI947-5-1

Aperturaforzata1ConformeallanormaIEC947-5-1

AberturaPositiva1paraIEC947-5-1

DifferentialTravel1 Carreradiferencial1 Differenzweg1 Coursedifférentielle1 Corsadifferenziale1 PercursoDiferencial1

OverTravel Sobrecarrera Nachlaufweg Surcourse Oltrecorsa Sobrepercurso

MaximumOperatingForce

Fuerzadefunciona-mientomáxima

MaximaleBetätigung-skraft

Forcedecommutationmaximum

Forzamassimadiintervento

ForçaMáximadeOperação

MaximumDisconnectForce

Fuerzadedesconex-iónmáxima

MaximaleÖffnung-skraft

Forcededéconnexionmaximum

Forzamassimadiscollegamento

ForçaMáximadeDesconexão

1. 2. 3.

FIELD ADJUSTABLE HEAD CAMPO DE CABEZA AJUSTABLEFIELD VERSTELLBAREM KOPF TÊTE DE CHAMP RÉGLABLECAMPO TESTA REGOLABILE CABEÇA CAMPO AJUSTÁVE

OPERATION REQUIREMENTS REQUISITOS DE FUNCIONAMIENTOANFORDERUNGEN AN DEN BETRIEB EXIGENCES DE FONCTIONNEMENTREQUISITI PER L’ESERCIZIO REQUISITOS DE OPERAÇÃO

TERMS CONDICIONESBEDINGUNGEN TERMESTARIFFE CONDIÇÕES

Page 5: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl5

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Figure 1. Reading Operating Specifications

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g de

-gr

ees,

max

.

Oper

atin

g de

gree

s, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01AGL**07A

SNAP-ACTION CONTACTSSINGLE POLE

Zb

><

21-2213-14

20° 56°**

12° Differential travel

9,7N[2.2lb]

11,4N[2.6lb]

0,85M/S[33.5in/S]

8,5mm/S[0.33in/S] 250

Ç Ç Ç Ç Ç Ç Ç ÇCatalog Listing Code

Contact Block DiagramShowsthecircuitcon-figurationoftheinternal

contactblock.

Operating Bar ChartsShowthestateofthecontactsrelativetothe

positionoftheactuator.

Operating Specifications

PRODUCT NOMENCLATURE

GL

Switch Type

A

F

EN50041,non-plug-in

EN50041, non-plug-in,LED light box

Body StyleCode

A

G

A

B

1/2-14 NPT

PG 13.5

Conduit EntryThreading Code

A

C 20 mm

GL SeriesGlobalLimit

Switch

EN50041, plug-in,LED light box

HEN50041, plug-in,LED light box

B EN50041,plug-in

D PF 1/2

3

2

1 CW rotationonly

CCW rotationonly

Lever toright

4 Lever toleft

04

05

03

01 SPDTsnap action

SPDT, BBMslow acting

SPDT, MBBslow acting

SPDT, 2NOslow acting

20

21

06 SPDT, 2NCslow acting

DPDT, snap action,sequential

DPDT, snap action

22DPDT, snap action, gold contacts

25

24DPDT, snap action, gold cont.Body E

01

Basic Switch

5 Lever to mounting surf.

6Rollerperpendicularto mtg. surf.

29

30

28

27 DPDT, snap action, center neutral, Body E

32

33

31DPDT, snap action, gold,sequen., Body E

SPDT, BBM,slow acting,gold contacts

34

35SPDT, 2NOslow acting,gold contacts

SPDT, MBBslow acting,gold contacts

36SPDT, 2NCslow acting,gold contacts

DPDT, snap action, Body E

DPDT, snap action, gold,sequentialDPDT, snap action, center neutral, gold

DPDT, snap act, center neutral, gold, Body E

DPDT, snap action, gold cont.Body E

A2A

A2B

A1B

A1ASide rotary,fixed, 19 x 6 nylon roller

A1A

Head/Actuator

A2W

A3A

A2D

F

K8A

K8B

A3B

A1

A2

A4J

A4K

A1Y

A2Y

Side rotary,fixed, 19 x 6 steel roller

Side rotary,adjust., 19 x 6 nylon roller

Side rotary,adjust., 19 x 6 steel roller

Side rotary,adjust., 38 x 6 nylon roller

Side rotary,adjust., 38 x 12 rubber roller

Side rotary,yoke, 19 x 6 nylon roller

Side rotary,yoke, 19 x 6 steel roller

Side rotary,adjust., 200 mmaluminum rod

Side rotary,fixed, no roller

Adj. top roller lever, Ø27,3 x5 POM roller

Cat whisker,140 mm

Cat whisker,190 mm

Side rotary,adjustable, no roller

Side rotary,fixed, 50 x 10 rubber roller

Side rotary,adj., 50 x 10 rubber roller

K8C Wobble,cat whisker

A5A

A5B

A9A

B

Side rotary,offset, 19 x 6 nylon roller

Side rotary,offset, 19 x 6 steel rollerSide rotary,conveyorlever

Top pinplunger

D

CTop rollerplunger

Top rollerlever

Side rotary,adjust., 140 mmaluminum rod

A4NSide rotary,adjust., 318 mmaluminum rod

E7A Wobble,plastic stick

E7B Wobble,coil

E7D Wobble,cat whisker

26DPDT, snap action, center neutral

07 SPDT, snapaction, gold

Page 6: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

6 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Figure 2. Fixed Lever, Side Rotary Switch - Non-plug-in Body Style, GLZ51 lever, and GLA body

LEVER ROLLERMATL

X DIM Y DIM Z DIM

GLZ51A NYLON 19,1.75

55,92.20

6,4.25

GLZ51B STEEL 19,1.75

55,92.20

6,4.25

GLZ51C NYLON 24,51.00

59,12.33

12,7.50

GLZ51Y RUBBER 50,01.97

66,12.60

10,0.39

GLZ51T STAINLESSSTEEL

19.1.75

56.82.24

8.8.345

70,00 MAX

2,756

20,0 mm0.79 in

Y

Z

CONDUITENTRY

75,8 mm2.99 in

62,0 mm2.44 in

38,1 mm1.50 in

16,0 mm0.63 in

82,0 mm3.23 in

102,9 mm4.05 in

31,5 mm1.24 in

42,0 mm1.65 in

5,3 mm0.21 in

30,0 mm1.18 in

42,0 mm1.65 in

60,0 mm2.36 in

Ø 5,3 mmØ 0.21 in

7,3 mm0.29 in

Ø X

(catalog listing)

Ø 19,1 mm [Ø 0.75 in]

5,3

CONDUITENTRY

20,0 mm[0.79 in]

75,8 mm[2.99 in]

62,0 mm[2.44 in]

38,1 mm[1.50 in]

16,0 mm[0.63 in]

102,9 mm[4.05 in]

31,5 mm[1.24 in]

41,5 mm[1.63 in]

30,0 mm[1.18 in]

42,0 mm[1.65 in]

60,0 mm[2.36 in]

Ø 5,3 mm[Ø 0.21 in]

7,3 mm[0.29 in]

70,00 mm max.[2,756 in max.]

69,7 mm[2.74 in]

55,9 mm[2.20 in]

50,0 mm[1.97 in]

6,4 mm[0.25 in]

Figure 3. Fixed Lever, Side Rotary Switch - Plug-in Body Style, GLZ51 lever, and GLB body

Page 7: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl7

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

LEVER ROLLERMATL

X DIM Y DIM Z DIM

GLZ52A NYLON 19,1.75

65,92.59

6,4.25

GLZ52B STEEL 19,1.75

65,92.59

6,4.25

GLZ52D NYLON 38,11.5

65,92.59

6,4.25

GLZ52E NYLON 19,1.75

79,373.125

33,071.300

GLZ52W RUBBER 40,01.6

71,52.81

12,7.5

GLZ52Y RUBBER 50,01.97

68,82.71

10,0.39

Y

ZØ X

38,1 mm to 91,5 mm adjustment1.50 in to 3.60 in adjustment

GLZ54J: 201,5 mm [7.93 in]GLZ54K: 141,0 mm [5.56]

GLZ54J: 200,0 mm [7.87 in]GLZ54K: 140,0 mm [5.51]Aluminum Rod

6,5 mm [0.26 in]

Ø 3,2 mm [Ø 0.13 in]

59,2 mm [2.33 in]

Figure 4. Adjustable Lever Dimensions, GLZ52

Figure 5. Aluminum Rod Lever Dimensions, GLZ54

Page 8: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

8 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Differential Travel

8~

Operate Point

FullTravel

85º

26º

ReleasePoint

Figure 6. Head Code: A Side Rotary Angular Operating Characteristics

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g to

rque

max

.

Disc

onne

ct

torq

ue, m

ax.

Oper

atin

g de

-gr

ees,

max

.

Oper

atin

g de

gree

s, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01AGL**07A

SNAP-ACTION CONTACTSSINGLE POLE

Zb

><

21-2213-14

26° 55°** 85°

12° Differential travel

0.330Nm[2.9in-lb]

0.385Nm[3.4in-lb] 1290° 13° 250

GL**03AGL**33A

SLOW ACTING BREAKBEFORE MAKE

Zb

26° ** 85°

38°

21-2213-14

0.330Nm[2.9in-lb]

0.385Nm[3.4in-lb] 1290° 13° 250

GL**04AGL**34A

SLOW ACTING MAKEBEFORE BREAK

Zb 26°

85°38° **21-2213-14

0.330Nm[2.9in-lb]

0.400Nm[3.5in-lb] 1290° 13° 250

GL**05AGL**35A

SLOW ACTING

2X

85°38° **

23-2413-14 0.330Nm

[2.9in-lb]0.385Nm[3.4in-lb] 1290° 13° 250

GL**06AGL**36A

SLOW ACTING

2Y26° ** 85°

11-1221-22

0.330Nm[2.9in-lb]

0.385Nm[3.4in-lb] 1290° 13° 250

GL**20AGL**22AGL**24AGL**32A

SNAP ACTIONCONTACTS

DOUBLE POLE

><

11-12, 21-2213-14, 23-24

26° 55°** 85°

12° Differential travel

0.330Nm[2.9in-lb]

0.385Nm[3.4in-lb] 1290° 13° 250

GL**21AGL**25AGL**28AGL**31A

STEP 1

STEP 2

SNAP ACTIONCONTACTS

DOUBLE POLESEQUENCIAL

8° Differential travel

11-1213-1421-2223-24

27° 42°

><><

8° Differential travel

0.330Nm[2.9in-lb] n/a 1290° 13° 250

Notes:• Freeposition,operatepoint,overtravelandpre-travelallto

EN50041• Operatingcharacteristicsapplytocounterclockwise(CCW)

andclockwise(CW)actuation• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

Page 9: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl9

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g de

-gr

ees,

max

.

Oper

atin

g de

gree

s, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01AGL**07A

SNAP-ACTION CONTACTSSINGLE POLE

Zb

><

21-2213-14

20° 56°**

12° Differential travel

9,7N[2.2lb]

11,4N[2.6lb]

0,85M/S[33.5in/S]

8,5mm/S[0.33in/S] 250

GL**03AGL**33A

SLOW ACTING BREAKBEFORE MAKE

Zb

20° **

32°

21-2213-14

9,7N[2.2lb]

11,4N[2.6lb]

0,85M/S[33.5in/S]

8,5mm/S[0.33in/S] 250

GL**04AGL**34A

SLOW ACTING MAKEBEFORE BREAK

Zb 20°

32°21-2213-14

0°9,7N[2.2lb]

11,4N[2.6lb]

0,85M/S[33.5in/S]

8,5mm/S[0.33in/S] 250

GL**05AGL**35A

SLOW ACTING

2X

85°32°

23-2413-14 9,7N

[2.2lb]11,4N[2.6lb]

0,85M/S[33.5in/S]

8,5mm/S[0.33in/S] 250

GL**06AGL**36A

SLOW ACTING

2Y

20° **11-1221-22

0°9,7N[2.2lb]

11,4N[2.6lb]

0,85M/S[33.5in/S]

8,5mm/S[0.33in/S] 250

GL**20AGL**22AGL**24AGL**32A

SNAP ACTIONCONTACTS

DOUBLE POLE

><

11-12, 21-2213-14, 23-24

20° 56°**

12° Differential travel

9,7N[2.2lb]

11,8N[2.7lb]

0,85M/S[33.5in/S]

8,5mm/S[0.33in/S] 250

GL**21AGL**25AGL**28AGL**31A

STEP 1

STEP 2

SNAP ACTIONCONTACTS

DOUBLE POLESEQUENCIAL

7° Differential travel

11-1213-1421-2223-24

20° 38.5°

><><

8.5° Differential travel

9,7N[2.2lb] n/a 0,85M/S

[33.5in/S]8,5mm/S[0.33in/S] 250

GL**26JGL**27JGL**29JGL**30J

CCWSNAP ACTION

CONTACTSDOUBLE POLE

CENTER NEUTRALCW

8° Differential travel

11-1213-1421-2223-24

16°><><

8° Differential travel

9,7N[2.2lb] n/a 0,85M/S

[33.5in/S]8,5mm/S[0.33in/S] 250

Figure 7. Head Code: A • Side Rotary Cam Actuation Per EN50041Operating CharacteristicsNotes:• Camtravelforadjustable

leverapplieswhenleverisadjustedto38,1mm[1.5in]

• Refertopage5forin-structionsonhowtoreadoperatingcharacteristicsandspecifications

Differential Travel

Operate Point

Full Travel85º

11,4

52,0 mm[2.05 in]

54°

20,0 mm[0.79 in]

20,0 mm[0.79 in]

30°67,0 mm[2.64 in]

Ø19,1 mm[Ø0.75 in]

Ø19,1 mm[Ø0.75 in]

>52,0 mm[>2.05 in]

38,1 mm to 91,5 mm[1.5 in to 3.60 in]

Adjustment

30°

Page 10: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

10 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g ve

loci

ty, m

ax.

Oper

atin

g ve

loci

ty, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01BGL**07B

SNAP-ACTION CONTACTSSINGLE POLE

Zb

><

21-2213-14

35 33**

0.9 Differential travel

37.5 30.516N

[3.6lb]27N

[6.0lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**03BGL**33B

SLOW ACTING BREAKBEFORE MAKE

Zb 34

21-2213-14

35**37.5 30.5><

16N[3.6lb]

27N[6.0lb]

0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**04BGL**34B

SLOW ACTING MAKEBEFORE BREAK

Zb

21-2213-14

34**37.5 30.5><

35

16N[3.6lb]

27N[6.0lb]

0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**05BGL**35B

SLOW ACTING

2X

30.534

23-2413-14 >

<

37.5 16N[3.6lb]

27N[6.0lb]

0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**06BGL**36B

SLOW ACTING

2Y11-1221-22

30.535**><

37.5

34

16N[3.6lb]

27N[6.0lb]

0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**20BGL**22BGL**24BGL**32B

SNAP ACTIONCONTACTS

DOUBLE POLE

><

11-12, 21-2213-14, 23-24

0.9 Differential travel

30.53537.5 33**16N

[3.6lb]37N

[8.2lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**21BGL**25BGL**28BGL**31B

STEP 1

STEP 2

SNAP ACTIONCONTACTS

DOUBLE POLESEQUENCIAL

0.8 Differential travel

11-1213-1421-2223-24

33.8

><><

0.8 Differential travel

37.5 35 30.5

16N[3.6lb] n/a 0,1M/S

[3.9in/S]1,0mm/S[0.04in/S] 250

Figure 8. Head Code: BPin Plunger Operating Characteristics

35,0 mm[1.38 in]

Operate point

Differentialtravel

Fulltravel

30,5 mm[1.20 in]

Plungerdiameter10,0 mm[0.39 in]

Notes:• Freeposition,operatepoint,overtravel,andpretravelallto

EN50041• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

Page 11: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl11

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g ve

loci

ty, m

ax.

Oper

atin

g ve

loci

ty, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01CGL**07C

SNAP-ACTION CONTACTSSINGLE POLE

Zb

><

21-2213-14

48 46**

0.9 Differential travel

50.5 43.516N

[3.6lb]27N

[6.0lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**03CGL**33C

SLOW ACTING BREAKBEFORE MAKE

Zb 47

21-2213-14

><

48**50.5 43.516N

[3.6lb]27N

[6.0lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**04CGL**34C

SLOW ACTING MAKEBEFORE BREAK

Zb

21-2213-14

47**><

48

50.5 43.516N

[3.6lb]27N

[6.0lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**05CGL**35C

SLOW ACTING

2X

47

23-2413-14 >

<

50.5 43.516N

[3.6lb]27N

[6.0lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**06CGL**36C

SLOW ACTING

2Y11-1221-22

48**><

50.5 43.516N

[3.6lb]27N

[6.0lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**20CGL**22CGL**24CGL**32C

SNAP ACTIONCONTACTS

DOUBLE POLE

><

11-12, 21-2213-14, 23-24

0.9 Differential travel

48 46**50.5 43.516N

[3.6lb]37N

[8.2lb]0,1M/S[3.9in/S]

1,0mm/S[0.04in/S] 250

GL**21CGL**25CGL**28CGL**31C

STEP 1

STEP 2

SNAP ACTIONCONTACTS

DOUBLE POLESEQUENCIAL

0.8 Differential travel

11-1213-1421-2223-24

45.8

><><

0.8 Differential travel

4850.5 43.5

16N[3.6lb] n/a 0,1M/S

[3.9in/S]1,0mm/S[0.04in/S] 250

Figure 9. Head Code: CTop Roller Plunger Pin Actuation Operating Characteristics

Notes:• Freeposition,operatepoint,overtravel,andpretravelallto

EN50041• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

48,0 mm[1.89 in]

Operate point

Differentialtravel

Fulltravel

43,5 mm[1.71 in]

Rollerdiameter

Ø12,7 mm[Ø0.50 in]

Page 12: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

12 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g ve

loci

ty, m

ax.

Oper

atin

g ve

loci

ty, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01CGL**07C

SNAP-ACTION CONTACTSSINGLE POLE

Zb

21-2213-14

15 18.3**

1.8 Differential travel

0><

9,3N[2.1lb]

15,6N[3.5lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**03CGL**33C

SLOW ACTING BREAKBEFORE MAKE

Zb

21-2213-14

15**0><

16.8

9,3N[2.1lb]

15,6N[3.5lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**04CGL**34C

SLOW ACTING MAKEBEFORE BREAK

Zb

21-2213-14

><

16.8**0

15

9,3N[2.1lb]

15,6N[3.5lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**05CGL**35C

SLOW ACTING

2X 23-2413-14

0><

16.8 9,3N[2.1lb]

15,6N[3.5lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**06CGL**36C

SLOW ACTING

2Y21-2213-14

15**0><

9,3N[2.1lb]

15,6N[3.5lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**20CGL**22CGL**24CGL**32C

SNAP ACTIONCONTACTS

DOUBLE POLE

11-12, 21-2213-14, 23-24

15 18.3**

1.8 Differential travel

0><

9,3N[2.1lb]

21,4N[4.8lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**21CGL**25CGL**28CGL**31C

STEP 1

STEP 2

SNAP ACTIONCONTACTS

DOUBLE POLESEQUENCIAL

1.4 Differential travel

11-1213-1421-2223-24

><><

1.4 Differential travel

15 16.90

9,3N[2.1lb] n/a 0,17M/S

[6.7in/S]1,7mm/S[0.067in/S] 250

Figure 10. Head Code: CRoller Plunger Cam Actuation Per EN50041 Operating Characteristics

Notes:• Freeposition,operatepoint,overtravel,andpretravelallto

EN50041• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

10,9,43

Differential travel

Operate point

Ø12,7 mm[Ø0.50 in]

44,0 mm[1.73 in]

20,0 mm[0.79 in]

30°

15,0 mm [0.59 in]

58,0 mm[2.28 in]

Page 13: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl13

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g ve

loci

ty, m

ax.

Oper

atin

g ve

loci

ty, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01DGL**07D

SNAP-ACTION CONTACTSSINGLE POLE

Zb

21-2213-14

61 56.9**

1.7 Differential travel

65.2 52><

9,5N[2.1lb]

12N[2.7lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**03DGL**33D

SLOW ACTING BREAKBEFORE MAKE

Zb

21-2213-14

61**65.2 52><

59.1

9,5N[2.1lb]

12N[2.7lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**04DGL**34D

SLOW ACTING MAKEBEFORE BREAK

Zb

21-2213-14

59.1**65.2 52><

61

9,5N[2.1lb]

12N[2.7lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**05DGL**35D

SLOW ACTING

2X 23-2413-14

65.2><

59.1 52 9,5N[2.1lb]

12N[2.7lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**06DGL**36D

SLOW ACTING

2Y11-1221-22

61**65.2 52><

9,5N[2.1lb]

12N[2.7lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**20DGL**22DGL**24DGL**32D

SNAP ACTIONCONTACTS

DOUBLE POLE

11-12, 21-2213-14, 23-24

61 56.9**

1.7 Differential travel

65.2 52><

9,5N[2.1lb]

16,4N[3.7lb]

0,17M/S[6.7in/S]

1,7mm/S[0.067in/S] 250

GL**21DGL**25DGL**28DGL**31D

STEP 1

STEP 2

SNAP ACTIONCONTACTS

DOUBLE POLESEQUENCIAL

1.6 Differential travel

11-1213-1421-2223-24

><><

1.6 Differential travel

61 58.6**65.2

9,5N[2.1lb] n/a 0,17M/S

[6.7in/S]1,7mm/S[0.067in/S] 250

Figure 11. Head Code: DTop Roller Lever Pin Actuation Operating Characteristics

Notes:• Freeposition,operatepoint,overtravel,andpretravelallto

EN50041• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

Operate point

Differentialtravel

Fulltravel

52,0 mm[2.05 in]

61,0 mm[2.40 in]

65,4 mm[2.57 in]

Ø18,7 mm[Ø0,74 in]

Page 14: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

14 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g ve

loci

ty, m

ax.

Oper

atin

g ve

loci

ty, m

in.

Max

. ope

rate

fre

quen

cy o

ps/

min

GL**01DGL**07D

SNAP-ACTION CONTACTSSINGLE POLE

Zb

21-2213-14

20 29.1**

4.1 Differential travel

0><

5,5N[1.2lb]

7,0N[1.6lb]

0,29M/S[11.4in/S]

2.9mm/S[0.11in/S] 250

GL**03DGL**33D

SLOW ACTING BREAKBEFORE MAKE

Zb

21-2213-14

20**0><

24.1

5,5N[1.2lb]

7,0N[1.6lb]

0,29M/S[11.4in/S]

2.9mm/S[0.11in/S] 250

GL**04DGL**34D

SLOW ACTING MAKEBEFORE BREAK

Zb

21-2213-14

><

20

0 24.1**5,5N[1.2lb]

9,6N[2.2lb]

0,29M/S[11.4in/S]

2.9mm/S[0.11in/S] 250

GL**05DGL**35D

SLOW ACTING

2X13-1423-24

><

0 24.1 5,5N[1.2lb]

7,0N[1.6lb]

0,29M/S[11.4in/S]

2.9mm/S[0.11in/S] 250

GL**06DGL**36D

SLOW ACTING

2Y11-1221-22

><

20**0 5,5N[1.2lb]

7,0N[1.6lb]

0,29M/S[11.4in/S]

2.9mm/S[0.11in/S] 250

GL**20DGL**22DGL**24DGL**32D

SNAP ACTIONCONTACTS

DOUBLE POLE

11-12, 21-2213-14, 23-24

29.1**

4.1 Differential travel

><

200

5,5N[1.2lb]

7,0N[1.6lb]

0,29M/S[11.4in/S]

2.9mm/S[0.11in/S] 250

GL**21DGL**25DGL**28DGL**31D

STEP 1

STEP 2

SNAP ACTIONCONTACTS

DOUBLE POLESEQUENCIAL

3.7 Differential travel

11-1213-1421-2223-24

><><

3.7 Differential travel

200 25.5

5,5N[1.2lb] n/a 0,29M/S

[11.4in/S]2.9mm/S[0.11in/S] 250

Figure 12. Head Code: DTop Roller Lever Cam Actuation per EN50041 Operating Characteristics

Notes:• Freeposition,operatepoint,overtravel,andpretravelallto

EN50041• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

11,4Differential travel

Operate point

20,0 mm[0.79 in]

20,0 mm[0.79 in]

Ø18,7 mm[Ø0,74 in]

52,0 mm[2.05 in]

67,0 mm[2.64 in]

30°

Page 15: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl15

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Head Code: E • WOBBLE AND CAT WHISKER ACTUATOR DIMENSIONSFigure 13. Coil Actuator Figure 14. Plastic Rod and Flexible Cable

Plastic tip 16,0 mm[0.63 in]

141,1 mm[5.55 in]

5.5 inches (stainless steel) 6.5 inches (stainless steel) 7.5 inches (stainless steel)

Ø1,2 mm[Ø0.05 in]

139,7 mm[5.50 in]

Ø1,3 mm[Ø0.05 in]

165,1 mm[6.50 in]

Ø1,2 mm[Ø0.05 in]

190,5 mm[7.5 in]

150,3 mm[5.92 in]

Ø6,4 mm[Ø0.25 in]

Plastic

153,5 mm[6.04 in]

Cable

Figure 15. Cat Whisker Wobbles

Page 16: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

16 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g de

-gr

ees,

max

.

Oper

atin

g ve

loci

ty, m

in.

Max

. ope

rate

ra

te c

ycle

s/m

in

GL**01KGL**07K

SNAP-ACTION CONTACTSSINGLE POLE

Zb

><

21-2213-14

18°

8° Differential travel

0,1N[0.9lb] n/a 360° 8° 100

GL**03KGL**33K

SLOW ACTING BREAKBEFORE MAKE

Zb

18°

25°

21-2213-14

><

0,1N[0.9lb] n/a 360° 8° 100

GL**04KGL**34K

SLOW ACTING MAKEBEFORE BREAK

Zb 18°

25°21-2213-14

><

0,1N[0.9lb] n/a 360° 8° 100

GL**05KGL**35K

SLOW ACTING

2X

25°

23-2413-14 >

<

0,1N[0.9lb] n/a 360° 8° 100

GL**06KGL**36K

SLOW ACTING

2Y

18°11-1221-22

0,1N[0.9lb] n/a 360° 8° 100

GL**20KGL**22KGL**24KGL**32K

SNAP ACTIONCONTACTS

DOUBLE POLE

><

11-12, 21-2213-14, 23-24

18°

8° Differential travel

0,1N[0.9lb] n/a 360° 8° 100

Figure 16. Head Code: EWobble Stick Angular Actuation Operating Characteristics

Notes:• Freeposition,operatepoint,overtravel,andpretravelallto

EN50041• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

Differentialtravel

Operate point

26,0 mm[1.02 in]

100,0 mm[3.94 in]

70,0 mm[2.76 in]

18°

Fulltravel

140,8 mm[5.54 in]

Page 17: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

HoneywellSensingandControl17

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

Catalog listing Contact block diagram

Nominal travels and related terminalsContact Closed Contact Open Diff. Travel

**Positive Opening to IEC 947-5-1 Oper

atin

g fo

rce

max

.

Disc

onne

ct

forc

e, m

ax.

Oper

atin

g ve

loci

ty, m

ax.

Oper

atin

g ve

loci

ty, m

in.

Max

. ope

rate

ra

te c

ycle

s/m

in

GL**01KGL**07K

SNAP-ACTION CONTACTSSINGLE POLE

Zb

><

21-2213-14

26°

12° Differential travel

1,3N[0.3lb] n/a 0,5M/S

[19.7in/S]11mm/S[0.43in/S] 100

GL**03KGL**33K

SLOW ACTING BREAKBEFORE MAKE

Zb

26.5°

38.1°

21-2213-14

><

1,3N[0.3lb] n/a 0,5M/S

[19.7in/S]11mm/S[0.43in/S] 100

GL**04KGL**34K

SLOW ACTING MAKEBEFORE BREAK

Zb 26.5°

38.1°21-2213-14

><

1,3N[0.3lb] n/a 0,5M/S

[19.7in/S]11mm/S[0.43in/S] 100

GL**05KGL**35K

SLOW ACTING

2X

38.1°21-2213-14

><

1,3N[0.3lb] n/a 0,5M/S

[19.7in/S]11mm/S[0.43in/S] 100

GL**06KGL**36K

SLOW ACTING

2Y

26.5°11-1221-22

><

1,3N[0.3lb] n/a 0,5M/S

[19.7in/S]11mm/S[0.43in/S] 100

GL**20KGL**22KGL**24KGL**32K

SNAP ACTIONCONTACTS

DOUBLE POLE

><

11-12, 21-2213-14, 23-24

26°

12° Differential travel

1,3N[0.3lb] n/a 0,5M/S

[19.7in/S]11mm/S[0.43in/S] 100

Figure 17. Head Code: KWobble Stick Angular Actuation Operating Characteristics

Notes:• Freeposition,operatepoint,overtravel,andpretravelallto

EN50041• Refertopage5forinstructionsonhowtoreadoperating

characteristicsandspecifications

Differentialtravel

Operate point

26,0 mm[1.02 in]

100,0 mm[3.94 in]

70,0 mm[2.76 in]

18°

Fulltravel

140,8 mm[5.54 in]

Page 18: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

18 HoneywellSensingandControl

Installation Instructions for MICRO SWITCH™ GLS Limit Switches

ISSUE 2 81501

WARRANTY/REMEDYHoneywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a par-ticular purpose. In no event shall Honeywell be liable for consequen-tial, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuit-abilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weas-sumenoresponsibilityforitsuse.

GARANZIA/RISARCIMENTOHoneywellgarantiscecheipropriprodottisonoesentidadifettineimate-rialienellamanodopera.RimanevalidalagaranziadiprodottostandardHoneywell,senondiversamenteconcordatodallastessaperiscritto.Fareriferimentoallaricevutadell’ordineorivolgersiall’ufficiovenditedellapropriazona,perulterioridettaglisullagaranzia.Duranteilperiododivaliditàdellagaranzia,Honeywellprovvederàallariparazioneoallasos-tituzione,asuadiscrezioneesenzaalcunaddebitodegliarticolirestituitieriscontratidifettosi.Tale azione costituisce l’unico risarcimento per l’acquirente e sostituisce tutte le altre garanzie, esplicite o implicite, incluse quelle della commerciabilità e dell’idoneità ad uno scopo particolare. In nessun caso Honeywell è da ritenersi responsabile per danni conseguenti, speciali o indiretti.

Honeywellfornisceassistenzainmeritoalleapplicazionitramiteilpropriopersonale,ilpropriomaterialeinformativoedilpropriositoWeb;tuttaviaèresponsabilitàdelclienteverificarel’idoneitàdelprodottoall’applicazione.

Idatitecnicisonosoggettiamodificasenzaalcunpreavviso.Leinformazionifornitenelpresentedocumentosonodaritenereaccurateedaffidabili.Tuttavia,Honeywellnonsiassumealcunaresponsabilitàinmeritoalloroimpiego.

GARANTIE UND HAFTUNGSANSPRÜCHEHoneywellgarantiertfürseinehergestelltenProduktefehlerfreiesMaterialundQualitätsarbeit.EsgiltdiedurchHoneywellschriftlichmitgeteilteStandard-ProduktgarantievonHoneywell.InformationenzuGarantie-detailsfindenSieaufIhrerAuftragsbestätigungbzw.erhaltenSievonIhrerörtlichenNiederlassung.WennProduktemitGarantieinnerhalbderGarantiefristanHoneywellzurückgesendetwerden,ersetztoderrepariertHoneywelldiealsfehlerhaftangesehenTeilenacheigenemErmessenkostenlos.Das Vorangegangene gilt als einzige Entschädigung des Käufers und ersetzt alle anderen ausdrücklichen oder stillschwei-genden Garantien, einschließlich Qualitäts- und Sachmängelhaftung. In keinem Fall haftet Honeywell für mittelbare, indirekte oder Sonde-schäden.

ObwohlHoneywellpersönlicheundschriftlicheAnwendungshilfesowieInformationenüberdieHoneywellWebsitebietet,istesdieEntscheidungdesKunden,obdasProduktsichfürdieentsprechendeAnwendungeignet.

ÄnderungendertechnischenDatenohneVorankündigungsindvorbe-halten.DiehiergegebenenInformationensindnachunseremWissenzumZeitpunktderDrucklegungkorrekt.Wirübernehmendennochkeiner-leiVerantwortungfürderenVerwendung.

GARANTIE/RECOURSHoneywellgarantitquelesarticlesdesafabricationsontexemptsdedéfautsdepiècesetmaind’œuvre.LagarantiestandardsurlesproduitsHoneywellestd’applicationsaufindicationcontraireécriteetapprouvéeparHoneywell.Veuillezvousreporteraurécépissédevotrecommandeouconsultervotrebureaudeventelocalpourobtenirdesdétailsspéci-fiquessurlagarantie.SilesarticlesgarantissontretournésàHoneywellpendantlapériodedecouverture,Honeywellrépareraouremplacera,àsadiscrétion,gratuitementceuxquiaurontététrouvésdéfectueux.Ce qui précède constitue le seul recours de l’acheteur et se substitue à toutes autres garanties, explicites ou implicites, y compris celles rela-tives à la commercialisation ou la compatibilité avec une application particulière. Honeywell ne peut être en aucun cas tenu responsable de tout dommage indirect, spécial ou accessoire.

BienquenousfournissionsuneassistanceauxapplicationsparlebiaisdenotrebibliographieetlesiteWebHoneywell,ilappartientauclientdedéterminerl’aptitudeduproduitpoursonapplication.

Lescaractéristiquestechniquespeuventchangersanspréavis.Lesinfor-mationsquenousdiffusonssontréputéesprécisesetfiablesaumomentdeleurimpression.Nousn’assumonscependantaucuneresponsabilitépourleurusage.

CLAUSULA DE GARANTÍAHoneywellgarantizaquetodoslosproductosquefabricaestánlibresdedefectosdemanodeobraomateriales.Lagarantíadelproductoestán-dardeHoneywellseaplicaamenosqueHoneywellhayaacordadolocontrarioporescrito;consulteasuconfirmacióndeordenoasuoficinadeventaslocalparadetallesespecíficosdegarantía.SisedevuelvenproductoscongarantíaaHoneywellduranteelperíododecobertura,Honeywelllosrepararáoreemplazará,demaneraopcional,sideterminaqueestándefectuosos.Esta cláusula de garantía sustituye a cualquier otra garantía, ya sea explícita o implícita. En ningún caso Honeywell será responsable por daños consecuentes, especiales o indirectos.

AunqueHoneywellofreceasistenciapersonalparalasaplicacionespormediodesuspublicacionesypáginasweb,eselclientequiendebedeterminarlaidoneidaddelproductoenlaaplicación.

Lasespecificacionespuedencambiarsinprevioaviso.Lainformaciónsuministradaesconsideradacorrectayfiableenelmomentodeestaimpresión.Noobstante,noasumimoslaresponsabilidadporsuuso.

GARANTIA/SOLUÇÕESAHoneywellgaranteseusprodutoscontradefeitosdematerialedefab-ricação.AgarantiapadrãodeprodutodaHoneywellseaplicaamenosquehajaumacordodiferenteporescritocomaHoneywell;consulteasuaconfirmaçãodeencomendaouconsulteoescritóriodevendaslocalparaobterdetalhesespecíficosdagarantia.QuandoprodutosdentrodoperíododecoberturadagarantiaforemdevolvidosàHoneywell,estasecomprometearepararousubstituir,deacordocomaopçãodaempresa,porumnovoaquelesprodutosqueconsiderardefeituosos. O acima estipulado é a única solução oferecida ao comprador e sub-stitui quaisquer outras garantias, expressas ou implícitas, inclusive garantias de comerciabilidade e adequação a um fim específico. Em hipótese alguma a Honeywell deve ser responsabilizada por danos conseqüenciais, especiais ou indiretos.

EmboraaHoneywellproporcioneassistênciapessoal,atravésdelitera-turaedeseusitenaweb,cabeaoclientedeterminarqualprodutoémaisadequadoàsuaaplicação.

Especificaçõespodemseralteradassemavisoprévio.Acreditamosqueasinformaçõesaquicontidaseramasmaisprecisaseconfiáveisnomomentodaimpressãodestapublicação.Noentanto,nãoassumimosqualquerresponsabilidadepelousodestas.

Page 19: Ui EN60947-5-1 81501 · 5. Connect stranded wire 2(0,75 mm2 to 2,5 mm, 18-14 AWG) or solid wire 2(0,75 mm2 to 1,5 mm, 18-16 AWG) to connector terminals (use 90 *C wire when ambient

Sensing and Control

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422

honeywell.com

81501-2-EN IL50GLO PrintedinUSA.December2012©2012HoneywellInternationalInc.Allrightsreserved.