typical mounting details of street name · pdf fileaccordance with the specification of...

1

Click here to load reader

Upload: phamkhanh

Post on 17-Mar-2018

214 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: TYPICAL MOUNTING DETAILS OF STREET NAME · PDF fileaccordance with the specification of painting or repainting of public lighting columns as stipulated in the current lighting MOM

REFERENCE

SCALE

DRAWING No. CAD

REF. REVISION SIGNATURE DATE

HIGHWAYS DEPARTMENT

TYPICAL ELEVATION

New Issue

SECTION A-A

H 2231

Nylon washer

Stainless steel

washer

15 20 40 40 20 15

6

6

6

6

TYPICAL MOUNTING DETAILS

A A

6

Existing public

lighting column

Double street name

plate or traffic sign

symmetrically installed

Galvanized steel bracket

fabricated from 40x6

mild steel flat

NOT TO SCALE

Existing footway

/ground level

Stainless steel

spring

M10 stainless steel bolt

75 75

Hole for M10 bolt

3x40 Rubber pad

25

Galvanized mild

steel collar

Galvanized mild

steel collar

M10 stainless steel

bolt & Nylon washer

& Spring washers

Notes :

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Aluminium channel fixed to street

name plate or traffic sign ( see

HyD Standard Drawing No. H2211C )

All dimensions are in millimeters.

All steelwork (except stainless steel) shall be grade 43 to BS 4360 and

shall be hot dip galvanized to BS EN ISO 1461:1999.

Stainless steel bolts and nuts shall be Grade A2-70 to BS EN ISO 3506-1

and BS EN ISO 3506-2, spring washer shall be to BS ISO464:1995.

Refer to HyD Standard Drawings No. H2228B and 2229 for the

layout/position of the double street name plates and traffic signs.

For 5m and 8m columns, signage mounted parallel and perpendicular to

the road axis can co-exist provided the total projected area does not

exceed 0.4 sq.m.

For 10m and 12m columns, signage mounted parallel and perpendicular to

the road axis cannot co-exist. Maximum total projected area of the

signage shall be : -

i) 0.4 sq.m for signage mounted parallel to the road axis.

ii) 0.1 sq.m for signage mounted perpendicular to the road axis.

No signage of any kind shall be allowed:-

i) on 10m or 12m decorative lighting columns.

ii) if there is already permanent fixture like WiFi equipment, light shields etc mounted on the column.

All weld slag shall be removed with a chipping hammer and the welds

vigorously wire brushed and protected by two coats of zinc rich paint to

BS4652.

The painting of lighting column surface, when required, shall be in

accordance with the specification of painting or repainting of public lighting

columns as stipulated in the current lighting MOM contract. The colour of

the finish paint shall be silver grey to RAL 9007 for an unpainted column

or matching with the existing colour for a painted column.

i) The existing column number obstructed by the new SNP/TS shall be covered by paint of colour silver grey to RAL 9007 for an unpainted

column or matching with the existing colour for a painted column.

ii) The reprovision of lighting column number shall be the same orientation and shall comply with the specification of painting or repainting of public

lighting columns as stipulated in the current lighting MOM contract.

iii) The column painting and column number reprovisioning works should be completed by the contractor responsible for the attachment of SNP/TS.

TYPICAL MOUNTING DETAILS

OF STREET NAME PLATE OR

TRAFFIC SIGN ON PUBLIC

LIGHTING COLUMN

Feb 10