Type 585C Piston ActuatorsHigh Thrust CapabilityWith standard air supply, the Size 130 Type 585Ccan produce up to 111,000 Newtons (25,000 lbs) offorce.
Wide Range of SizesThe Type 585C family of actuators offers a widerange of sizes, with piston areas of 168 sq cm (26 sqin) up to 1,429 sq cm (221.5 sq in).
Rugged ConstructionThe Type 585C standard yoke material is ductileiron, resulting in robust construction and increasedthrust capability.
Broad Travel CapabilityType 585C piston actuators provide standard travellengths of up to 203 mm (8 in). The 585C LongStroke version is capable of travels up to 610 mm(24 in).
High Performance InstrumentationType 585C actuators are available with a variety ofpositioners and accessories, including the DVC6000Digital Valve Controller. The 377 Series Trip Valveand tank system are available for fail-safe action.
W7960 / IL
Figure 1. Type 585C Piston Actuator
Product Bulletin61.2:585CAugust 2002 585C Actuator
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
2
ContentsType 585C Features and Advantages 3. . . . . . . . . . Principle of Operation—585C 4. . . . . . . . . . . . . . . . . . Instrument Selection 6. . . . . . . . . . . . . . . . . . . . . . . . . DVC6010/6020 Digital Valve Controller 6. . . . . . . . . 3600 Series Positioner 7. . . . . . . . . . . . . . . . . . . . . . . Accessories 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 585C Installation 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . Actuator Data 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Handwheel Specifications 17. . . . . . . . . . . . . . . . . . . . Dimensions 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications—Type 585C Actuators
Sizes 25-130 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications—585C Long-Stroke Actuators 23. . . Specifications—DVC6000 Series Digital Valve
Controllers 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications—3600 Series Positioners 26. . . . . . .
W7447-1 / IL
STEMCONNECTOR
YOKE
CAP SCREW
PISTON O-RING
PISTON
CYLINDER
SPRING(SIZES 25 & 50)
TRAVEL STOP
STEM O-RING
SEAL BUSHING
TRAVELINDICATOR
ACTUATOR STEM
Figure 2. Type 585C Piston Actuator Components
585C ActuatorProduct Bulletin61.2:585CAugust 2002
3
The Type 585C Linear Piston Actuator
The Type 585C linear piston actuator is a powerful,double-acting actuator that provides accuratethrottling or on-off operation for sliding-stem controlvalves.
The Type 585C piston actuator family is available insizes 25 to 130 to cover a wide range of thrust andtravel length requirements. It can be used withswitching valves for on-off control, or with the Fisher
DVC6000 Series digital valve controller or 3600Series positioner for throttling applications.
The Type 585C has a wide-range of supply pressurecapabilities, up to 150 psig. As the Type 585C isdouble-acting, the positioner supplies air to bothsides of the piston, resulting in stiff, precisemovement and control.
The 585C piston actuator is also available in a longstroke version with travel capabilities up through 610mm (24 inches).
Type 585C Features and AdvantagesSee table 1.
Table 1. Type 585C Features and Advantages
Features Advantages
High thrust capabilityWith air supply capability of up to 150 psig, the Type 585C can produce up to111,000 Newtons (25,000 pounds) thrust to overcome high valve unbalance. Specialconstructions can produce thrusts of up to 137,000 Newtons (30,800 pounds).
Long stroke Depending on size, strokes of up to 203 mm (8 inches) (standard) are available.Longer travels of up to 610 mm (24 inches) are available upon request.
Wide range of sizes The Type 585C is available in standard sizes 25, 50, 60, 68, 80, 100, and 130.Larger cylinder sizes are available for special applications.
Valve mountingcapability
Depending on size, the Type 585C can be mounted to yoke boss diameters of 2-1/8inches through 5-inches, and valve stems of up to 1-1/4 inch diameter. Specialconstructions will accommodate a 7-inch yoke boss and a 2-inch valve stem.
Positioner mountingcapability
Universal NAMUR mounting provides a consistent mounting method for size 25through 130 actuators. This mounting capability provides vibration resistance perISA-S75.13.
High frequencyresponse
The double-acting construction of the Type 585C allows quick response toinstrument signals.
Stiff construction Pressure on both sides of the piston, plus the relatively small volume of air within thecylinder, results in stiff, precise positioning.
Handwheels Type 585C size 25 and 50 actuators are available with a top-mounted handwheel. Allother 585C actuator sizes can accommodate a side-mounted handwheel.
Bias springs
The sizes 25 and 50 are available with bias springs. A bias spring under the pistonfully retracts the actuator stem upon loss of supply air, while a bias spring on top ofthe piston fully extends the actuator stem. The spring bias mode is easily reversedwithout the need for additional parts.
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
4
E0409 / IL
Figure 3. Type 585C Piston Actuator Without Springs
Principle of Operation – 585CThe Type 585C piston actuator (figures 2 and 3)uses a piston that moves inside the actuatorcylinder. An O-ring (see figure 2) provides a sealbetween the piston and the cylinder.
From an equilibrium state, the actuator reacts to aforce unbalance that is created by increasing supplypressure on one side of the piston,and decreasing iton the other. This moves the piston up or down, andresults in a repositioning of the valve controlelement.
E0410 / IL
Figure 4. Type 585C Piston Actuator with Handwheel
Actuator with Handwheel (figures 4 and 13)The handwheel version can be used to open orclose the valve manually (either during normaloperation or in an emergency), to position the valveat any point in the stroke, or to act as a travel stop.
Size 25 and 50 actuators use an integraltop-mounted handwheel. See figure 13.
Size 60 to 130 actuators use a side-mountedhandwheel, and come with a spring-loaded balldetent which prevents vibration from changing thehandwheel setting. Handwheels for most types areeither 203 mm (8 inches) in diameter with beveledgears or 432 mm (17 inches) in diameter with wormgears.
585C ActuatorProduct Bulletin61.2:585CAugust 2002
5
W7447-1 / IL
Figure 5. Type 585C Piston Actuator with Spring Return
Actuator with Spring Return (figure 5)
Type 585C size 25 & 50 actuators are available withbias springs. The Type 585C actuator with biasspring has the spring under the piston and fullyretracts the actuator stem upon loss of cylinderpressure. The bias spring in the Type 585CRactuator is on top of the piston and fully extends theactuator stem upon loss of cylinder pressure. Noadditional parts are required to convert from oneactuator type to the other.
W2795–1/IL
Figure 6. Type 585C Long-Stroke Actuator
Type 585C Long-Stroke Construction
When especially high thrust or long stroke isrequired, the Type 585C Long-Stroke piston actuatoris the answer (see figure 6). The versatility of theLong-Stroke version allows accommodation of 16different valve travels, up through 610 mm (24inches). Available thrusts are impressive too, withthrust capability of up to 137,800 newtons (30,800lbs).
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
6
Instrument SelectionAn excellent selection of sensitive and accurateinstruments is available for Type 585C pistonactuators. These include the DVC6000 Series digitalvalve controller, as well as the 3600 Seriespneumatic (P/P) and electro-pneumatic (I/P)positioners.
DVC6010/6020 Digital Valve Controller
FIELDVUE� DVC6000 Series digital valvecontrollers, figure 7, are communicating,microprocessor-based current-to-pneumaticinstruments. In addition to the traditional function ofconverting a current signal to a pressure signal,DVC6000 Series digital valve controllers, usingHART� communications protocol, give easy accessto information critical to process operation. This canbe done using a Model 275 HART Communicator atthe valve or at a field junction box, or by using apersonal computer or a system console within thecontrol room. Using HART communication protocol,information can be integrated into a control systemor received on a single loop basis.
DVC6000 Series digital valve controllers can beused on single- or double-acting actuators. Thedigital valve controller receives feedback of the valvetravel position plus supply and actuator pneumaticpressure. This allows the instrument to diagnose notonly itself, but also the valve and actuator to which itis mounted. This provides you with very costeffective maintenance information, so that requiredmaintenance can be performed on the instrumentand valve when there really is a need.
Wiring is economical because DVC6000 Seriesdigital valve controllers use two-wire 4 to 20 mA looppower. This provides for low cost replacement ofexisting analog instrumentation. The DVC6000Series digital valve controller’s two-wire designavoids the high cost of running separate power andsignal wiring.
Principle of Operation—DVC6010/6020
DVC6000 Series instruments receive a set point andposition the valve where it needs to be. See figure 8.
� The input signal provides electrical power andthe set point simultaneously. It is routed into theterminal box through a twisted pair of wires.
W7960 / IL
Figure 7. Type DVC6010 Digital Valve Controller Mounted onType 585C Piston Actuator
� The input signal is then directed to the printedwiring board assembly where the microprocessorruns a digital control algorithm resulting in a drivesignal to the I/P converter.
� The I/P converter assembly is connected tosupply pressure and converts the drive signal into apressure output signal.
� The I/P output is sent to the pneumatic relayassembly. The relay is also connected to supplypressure and amplifies the small pneumatic signalfrom the I/P converter into a single larger pneumaticoutput signal used by a single-acting actuator. Fordouble-acting actuators, the relay accepts thepneumatic signal from the I/P converter and providestwo pneumatic output signals.
� The change in relay output pressure to theactuator causes the valve to move.
� Valve position is sensed through the feedbacklinkage by the instrument’s travel sensor. The travelsensor (or potentiometer) is electrically connected tothe printed wiring board to provide a travel feedbacksignal used in the control algorithm.
The valve continues to move until the correctposition is attained.
585C ActuatorProduct Bulletin61.2:585CAugust 2002
7
E0408 / IL
INPUT SIGNAL4–20 mA
+HART
SUPPLYPRESSURE
PRINTED WIRING BOARD
PNEUMATICRELAY
I/P CONVERTER
OUTPUT A
OUTPUT B
VALVE TRAVELFEEDBACK
AUXILIARYTERMINALS
TERMINAL BOX
DRIVESIGNAL
VALVE AND ACTUATOR
Figure 8. DVC6000 Series Digital Valve Controller Block Diagram
3600 Series Positioner3600 Series pneumatic (P/P) and electro-pneumatic(I/P) positioners are used in combination with eithersingle or double acting actuators to accuratelyposition control valves used in throttling applications.These accurate and vibration-resistant positionersprovide a valve position proportional to a pneumaticor a dc current input signal. Low steady-state airconsumption contributes to efficient operation.
The Type 585C piston actuator can be controlledwith the Type 3610JP or 3611JP pneumatic (P/P)positioner, and the 3620JP or 3621JPelectro-pneumatic (I/P) positioner.
Principle of Operation—3600 SeriesA switching device is required to control the loadingand unloading of supply pressure. A 4-way solenoidor a 3600 Series positioner can be used for throttlingservice. The P/P positioner accepts a pneumaticinput signal, whereas the I/P positioner accepts a dccurrent signal from a control device.
W4919 / IL
Figure 9. Type 3620JP/3621JP Electro-Pneumatic (I/P)Positioner Assembly
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
8
W4901–1*/IL
MINORLOOP GAINADJUSTMENT
COARSESPANADJUSTMENT
CROSSOVERADJUSTMENT
ZEROADJUSTMENT
FINE SPANADJUSTMENT
Figure 10. Adjustment for 3600 Series Positioners
The P/P positioner is a force-balanced instrumentthat provides an actuator stem position proportionalto the pneumatic input signal, as shown in figure 11.For direct action, input signal pressure from apneumatic instrument is channeled to cavity A in theinput module. An increase in input signal pressureresults in a downward force on the summing beam,pivoting the summing beam counterclockwise. Thismoves the flapper slightly toward the nozzle,increasing the nozzle pressure. As nozzle pressureincreases, the relay beam pivots clockwise, causingrelay B to increase upper cylinder pressure andRelay A to exhaust lower cylinder pressure of theactuator.
As a result, the actuator stem extends and the forceapplied to the summing beam by the range springincreases as the feedback lever rotates clockwise.This force, which opposes the downward force onthe summing beam caused by the increasing inputsignal pressure, continues to increase until thesumming beam torques are in equilibrium. At thispoint, the actuator stem is in the correct position forthe specific input signal applied.
For reverse action, input signal pressure ischanneled to both cavities A and B. An increase insignal pressure results in an upward force on the
summing beam, pivoting the summing beamclockwise and causing relay B to exhaust upperactuator cylinder pressure to atmosphere and relayA to increase lower actuator cylinder pressure. As aresult, the actuator stem retracts and the feedbackarm pivots counterclockwise reducing the forceapplied to the summing beam by the range spring.
As the actuator stem retracts, the range spring forceto the summing beam continues to reduce until thesumming beam torques are in equilibrium. At thispoint, the actuator stem is in the correct position forthe specific input signal applied.
The I/P positioner is a combination of a P/Ppositioner with a current-to-pressure converter. Theconverter provides a 0.2 to 1.0 bar (3 to 15 psig)output pressure proportional to the 4 to 20milliampere input signal. The 0.2 to 1.0 bar (3 to 15psig) output pressure becomes the input signalpressure to the P/P pneumatic positioner.
Accessories
Type 304 Electrical Valve Stem Position Switch—A cam operated limit switch assembly that canhouse from one to six snap-acting switches. Theposition switch shaft is rotated by linear motion ofthe valve stem and each cam can be adjusted toactivate its switch at the proper travel.
377 Series Trip Valve—Used when a specific valvefail action is required when supply pressure fallsbelow a specified pressure. Should supply pressurefall below the trip point, the trip valve can be set tocause the actuator piston to fail up, fail down orlock-in-last position.
4200 Series Electronic Position Transmitter—Theposition transmitter provides an electrical signal thatis proportional to the valve stem position. Dependingon the type of transmitter ordered, it provides atransmitter signal only, position switches only, or atransmitter signal with position switches for accuratevalve position indication.
GO Series Limit Switches (Size 60 to 130only)—Can be mounted on the yoke cover plate toelectrically indicate open or closed positions of thevalve.
585C ActuatorProduct Bulletin61.2:585CAugust 2002
9
38A8902-BB1846-1/IL
MINOR LOOPGAIN ADJ ZERO ADJ RANGE SPRING
COARSESPANADJ
CROSS-OVERADJ
RELAY BEAM
RELAYB
RELAYA
SUPPLY PRESSURE
NOZZLE PRESSURE
INPUT SIGNAL
OUTPUT SIGNAL
OUTPUT SIGNALAIRSUPPLY
FINESPANADJ
PIVOT B
INPUT MODULE
PIVOT AFLAP-PER
NOZZLE
FIXEDRESTRICTION
AIR SUPPLY
CAVITY ACAVITY B
INPUT SIGNALPRESSURE
PISTONACTUATOR
SUMMING BEAM COUNTER SPRING
FEEDBACKLEVER
38A6592-AB2157/IL ����������������� ��������������������������������
������������������������������������������
Figure 11. 3600 Series Principle of Operation
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
10
Actuator DataSee table 2 for piston cylinder clearance volumes,table 3 for yoke boss and valve stem diameters, and
tables 4, 5, 6, 7, 8, and 9 for actuator thrustcapabilities.
Table 2. Type 585C Piston Cylinder Clearance VolumesPISTON AT TOP OF CYLINDER (SPRINGS BELOW PISTON FOR SIZE 25 AND 50)
ActuatorSize
Piston Area Maximum Actuator Travel Upper Clearance Volume(figure 12)
Volume Below Piston(figure 12)
Sizecm2 Inches2 cm Inches cm3 Inches3 cm3 Inches3
25 168 26 2.9 1-1/8 104 6.3 1750 107
50 303 47 5.1 2 330 20 5200 320
5.1 2 310 19 2700 163
60 358 55.5 10 4 310 19 4400 27060 358 55.520 8 310 19 8200 500
5.1 2 1230 75 7500 460
68 571 88.5 10.2 4 1230 75 7500 46068 571 88.520.3 8 1230 75 13300 810
80 571 88 510.2 4 1230 75 7500 460
80 571 88.520.3 8 1230 75 13300 810
100 842 130 510.2 4 1700 104 10700 650
100 842 130.520.3 8 1700 104 19200 1170
130 1430 221 510.2 4 4600 280 18500 1130
130 1430 221.520.3 8 4600 280 33000 2000
PISTON AT BOTTOM OF CYLINDER (SPRINGS ABOVE PISTON FOR SIZE 25 AND 50)
ActuatorSize
Piston Area Maximum Actuator Travel Lower Clearance Volume(figure 12)
Volume Above Piston(figure 12)
Sizecm2 Inches2 cm Inches cm3 Inches3 cm3 Inches3
25 168 26 2.9 1-1/8 77 4.7 1790 109
50 303 47 5.1 2 350 22 5200 320
585C Installation
The actuator may be installed in any orientation butnormal installation is with the actuator vertical abovethe valve. Actuator and positioner dimensions areshown in figures 13, 14, 15, and 16.
If the supply source is capable of exceeding themaximum actuator operating pressure or instrumentsupply pressure, appropriate steps must be taken
during installation to protect the instrument and allconnected equipment against overpressure.
Note
Fisher does not assume responsibilityfor the selection, use, or maintenanceof any product. Responsibility forproper selection, use, andmaintenance of any Fisher productremains solely with the purchaser andend-user.
585C ActuatorProduct Bulletin61.2:585CAugust 2002
11
Table 3. Yoke Boss and Valve Stem Diameters
ACTUATOR SIZEYOKE BOSS DIAMETER VALVE STEM DIAMETER
ACTUATOR SIZEmm Inches mm Inches
25 5471
2-1/82-13/16
9.512.7
3/81/2
50 7190
2-13/163-9/16
12.719.1
1/23/4
60 90 3-9/16 19.1 3/4
68 90 3-9/16 19.1 3/4
80 127 5, 5H 25.431.8
11-1/4
100 127 5, 5H 25.431.8
11-1/4
130 127 5, 5H 31.8 1-1/4
Long Stroke 127178
5H(1)
725.4 or 31.8
50.81 or 1-1/4
21. Heavy actuator to bonnet bolting.
UPPERCLEARANCEVOLUME
VOLUMEBELOWPISTON
44B7218-C
LOWERCLEARANCEVOLUME
VOLUMEABOVEPISTON
44B7217-C
Figure 12. Clearance Volumes
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
12
Actuator Thrust CapabilitiesSee tables 4, 5, 6, 7, 8, and 9.
Table 4. Type 585C Size 25 and 50 Actuator Thrust Capabilities, U.S. Units (spring retracts stem)
ACTU- SPRINGACTUATOR
SPRING THRUST,POUNDS
NET THRUST FOR TYPE 585C WITH ACTUATOR STEM FULLYEXTENDED AT FULL TRAVEL
ACTU-ATOR
SPRINGRATE,
ACTUATORSTEM
TRAVEL Stem Stem Operating Pressure, psig(1) SPRINGCOLORATOR
SIZERATE,lb/in
TRAVEL,INCHES
StemRe-
d
StemEx-
d d40 50 60 70 80 90 100 110 125 150
COLORINCHES
tracted tended Force, Pounds
0 All 0 0 1040 1300 1560 1820 2080 2340 2600 2860 3250 3900Springs
Not Used
200
9/163/47/8
1-1/8
200200200200
313350375425
730690660610
990950920870
1250121011801130
1510147014401390
1760173017001650
2020199019601910
2280225022202170
2540251024802430
2930290028702820
3580355035203470
Gold
400
9/163/47/8
1-1/8
400400400400
625700750850
410340290190
670600550450
930860810710
119011201070970
1450138013301230
1710164015901490
1970190018501750
2230216021102010
2620255025002400
3270320031503050
LightGreen
25500
9/163/47/8
1-1/8
500500500500
781875938
1063
260160100
X
520420360240
780680620500
1040940880760
1300120011401010
1560146014001270
1820172016601530
2080198019201790
2460237023102180
3110302029602830
White
700
9/163/47/8
1-1/8
700700700700
1094122513131488
XXXX
20070XX
46033025070
720590510330
980850760590
124011101020850
1500137012801110
1760163015401370
2150202019301760
2800267025802410
Gold &White
900
9/163/47/8
1-1/8
900900900900
1406157516881913
XXXX
XXXX
150XXX
410240130
X
670500390160
930760650420
11901020910680
145012801170940
1840167015601330
2490232022101980
Light Green& White
0 All 0 0 1840 2300 2760 3220 3680 4140 4600 5060 5750 6900Springs
Not Used
330
3/47/8
1-1/81-1/2
2
330330330330330
578619701825990
1310127011801060900
17801740166015301370
22502210213020001840
27202680260024702310
31903150307029502780
36603620354034203250
41404090401038903720
46104570448043604190
53105270519050704900
64906450637062506080
Pink
600
3/47/8
1-1/81-1/2
2
600600600600600
10501125127515001800
84076061039090
131012301080860560
17801700155013301030
22502170202018001500
27202650250022701970
31903120297027402440
36603590344032102910
41304060391036803380
48404770462043904090
60205950580055705270
LightBlue
50930
3/47/8
1-1/81-1/2
2
930930930930930
16281744197623252790
260140
XXX
73061038030X
1200108085050040
167015601320970510
2140203017901450980
26102500227019201450
30902970274023901920
35603440321028602390
42604150391035703100
54405330509047504280
Pink &Light Blue
1550
3/47/8
1-1/81-1/2
2
15501550155015501550
27102906329438754650
XXXXX
XXXXX
110XXXX
580385
XXX
1050855465
XX
15201325935355
X
19901795140582550
2460226518751295520
31652970258020001225
43454150376031802405
Green
1880
3/47/8
1-1/81-1/2
2
18801880188018801880
32903525399547005640
XXXXX
XXXXX
XXXXX
XXXXX
470235
XXX
940705235
XX
14101175705
XX
188016451175470
X
2585235018801175235
37653530306023551415
Pink &Green
X indicates where the listed supply pressure is not sufficient to overcome the opposing bias spring effect.1. The maximum design pressure for size 25 and 50 actuator is 150 psig. Maximum rating for applications is 125 psig.
585C ActuatorProduct Bulletin61.2:585CAugust 2002
13
Table 5. Type 585C Size 25 and 50 Actuator Thrust Capabilities, Metric Units (spring retracts stem)
ACTU- SPRINGACTU-ATOR
SPRINGTHRUST, N
NET THRUST FOR TYPE 585C WITH ACTUATOR STEM FULLYEXTENDED AT FULL TRAVEL
ACTU-ATOR
SPRINGRATE,
ATORSTEM Stem Stem Operating Pressure, bar(1) SPRING
COLORATORSIZE
RATE,N/mm
STEMTRAVEL,
mm
StemRe-
d
StemEx-
d d2.8 3.4 4.1 4.8 5.5 6.2 6.9 7.6 8.6 10.3
COLOR
mm tracted tended Force, N
0 All 0 0 4626 5783 6939 8096 9252 10,409 11,565 12,722 14,457 17,348Springs
NotUsed
35.0
14.319.122.228.6
890890890890
1393155816691891
3247306929362713
4404422640923870
5560538252495026
6717653964056183
7829769575627340
8985885287188496
10,14210,008
98759653
11,29811,16511,03210,809
13,03312,90012,76612,544
15,92515,79115,65815,435
Gold
70.1
14.319.122.228.6
1780178017801780
2781311533383783
182415121290845
2980266924472002
4137382536033158
5293498247604315
6450613959165471
7606729570736628
8763845282297784
9919960893868941
11,65411,34311,12110,676
14,54614,23414,01213,567
LightGreen
25
87.6
14.319.122.228.6
2225222522252225
3475389441744730
1156712445
X
2313186816011068
3470302527582224
4626418139143381
5783533850714493
6939649462275649
8096765173846806
9252880785417962
10,94310,54210,275
9697
13,83413,43413,16712,588
White
122.6
14.319.122.228.6
3115311531153115
4868545158436622
XXXX
890311
XX
204614681112311
3203262422691468
4359378133812624
5516493845373781
6672609456944938
7829725168506094
9564898585857829
12,45511,87711,47610,720
Gold &White
157.7
14.319.122.228.6
4005400540054005
6257700975128513
XXXX
XXXX
667XXX
18241068578
X
298022241735712
4137338128911868
5293453740483025
6450569452044181
8185742869395916
11,07610,32098318807
LightGreen &
White
0 All 0 0 8180 10,200 12,300 14,300 16,400 18,400 20,500 22,500 25,600 30,700Springs
NotUsed
57.8
19.122.228.638.150.8
14681468146814681468
25712753311836704404
58275649524947154003
79187740738468066094
10,0089831947588968185
12,09911,92111,56510,98710,275
14,19014,01213,65613,12212,366
16,28016,10215,74715,21314,457
18,41618,19317,83717,30316,547
20,50620,32819,92819,39418,638
23,62023,44223,08622,55221,796
28,86928,69128,33527,80127,045
Pink
105.1
19.122.228.638.150.8
26692669266926692669
46715004567166728007
3736338127131735400
58275471480438252491
79187562689559164582
10,0089653898580076672
12,09911,78811,12110,097
8763
14,19013,87813,21112,18810,854
16,28015,96915,30214,27912,944
18,37118,06017,39216,36915,035
21,52921,21820,55119,52818,193
26,77826,46725,80024,77723,442
LightBlue
50
162.9
19.122.228.638.150.8
41374137413741374137
724277588790
10,34212,410
1157623
XXX
324727131690133
X
5338480437812224178
74286939587243152269
95199030796264504359
11,61011,12110,097
85416450
13,74513,21112,18810,631
8541
15,83615,30214,27912,72210,631
18,94918,46017,39215,88013,789
24,19823,70922,64121,12919,038
Pink &LightBlue
271.4
19.122.228.638.150.8
68946894689468946894
1205412925146521723620683
XXXXX
XXXXX
489XXXX
25801712
XXX
467038032068
XX
6761589441591579
X
8852798462493670222
1094210075834057602313
14078132111147688965449
19,32818,46016,72514,14510,698
Green
329.2
19.122.228.638.150.8
83628362836283628362
1463415679177702090625087
XXXXX
XXXXX
XXXXX
XXXXX
20911045
XXX
418131361045
XX
627252263136
XX
8362731752262091
X
1149810453836252261045
16,74815,70213,61210,4766294
Pink &Green
X—Indicates where the listed supply pressure is not sufficient to overcome the opposing bias spring effect.1. The maximum design pressure for size 25 and 50 actuator is 10.3 bar. Maximum rating for applications is 8.6 bar.
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
14
Table 6. Type 585C Size 25 and 50 Actuator Thrust Capabilities, U.S. Units (spring extends stem)
SPRING
SPRINGTHRUST W/ACTUATOR
TOTAL THRUST FOR TYPE 585CR WITH ACTUATOR STEM FULLYEXTENDED
ACTUATORSIZE
SPRINGRATE,
ACTUATORSTEM
Operating Pressure, psig(1) SPRINGS USED, BYCOLORSIZE
RATE,lb/in
STEMEXTENDED, 40 50 60 70 80 90 100 110 125 150
COLOREXTENDED,
POUNDS Force, Pounds
0 0 1040 1300 1560 1820 2080 2340 2600 2860 3250 3900Springs
Not Used
200 200 1240 1500 1760 2020 2280 2540 2800 3060 3450 X Gold
25(2)400 400 1440 1700 1960 2220 2480 2740 3000 3260 3650 X Light Green
25(2)500 500 1540 1800 2060 2320 2580 2840 3100 3360 3750 X White
700 700 1740 2000 2260 2520 2780 3040 3300 3560 X X Gold & White
900 900 1940 2200 2460 2720 2980 3240 3500 3760 X XLight Green
& White
0 0 1840 2300 2760 3220 3680 4140 4600 5060 5750 6900Springs
Not Used
330 330 2210 2680 3150 3620 4090 4560 5030 5500 6205 X Pink
50(3) 600 600 2480 2950 3420 3890 4360 4830 5300 5770 6475 X Light Blue50( )
930 930 2810 3280 3750 4220 4690 5160 5630 6100 6805 X Pink & Light Blue
1550 1550 3430 3900 4370 4840 5310 5780 6250 6720 X X Green
1880 1880 3760 4230 4700 5170 5640 6110 6580 7050 X X Pink & GreenX indicates where the listed supply pressure is not sufficient to overcome the opposing bias spring effect.1. The maximum design pressure for size 25 and 50 actuator is 150 psig.2. Maximum thrust is 3900 lbs.3. Maximum thrust is 6900 lbs.
Table 7. Type 585C Size 25 and 50 Actuator Thrust Capabilities, Metric Units (spring extends stem)
SPRING
SPRINGTHRUST W/ACTUATOR
TOTAL THRUST FOR TYPE 585CR WITH ACTUATOR STEM FULLYEXTENDED
ACTUATORSIZE
SPRINGRATE,
ACTUATORSTEM
Operating Pressure, bar(1) SPRINGS USED, BYCOLORSIZE
RATE,N/mm
STEMEXTENDED, 2.8 3.4 4.1 4.8 5.5 6.2 6.9 7.6 8.6 10.3
COLOREXTENDED,
N Force, N
0 0 4626 5782 6939 8095 9251 10408 11565 12721 14456 17347Springs
Not Used
35.0 890 5516 6672 7828 8985 10141 11298 12454 13610 15346 X Gold
25(2)70.0 1780 6405 7562 8718 9874 11031 12188 13344 14500 16235 X Light Green
25(2)87.6 2225 6850 8006 9163 10319 11476 12632 13789 14945 16680 X White
122.6 3115 7740 8896 10052 11209 12365 13655 14678 15835 X X Gold & White
157.6 4005 8629 9786 10942 12099 13255 14412 15568 16724 X XLight Green
& White
0 0 8180 10200 12300 14300 16400 18400 20500 22500 25600 30700Springs
Not Used
57.8 1468 9830 11921 14011 16102 18192 20282 22373 24464 27600 X Pink
50(3) 105.1 2670 11031 13122 15212 17303 19393 21484 23574 25665 28800 X Light Blue50( )
162.8 4135 12499 14589 16680 18770 20861 22952 25042 27133 30269 X Pink & Light Blue
271.4 6894 15256 17347 19438 21528 23619 25709 27800 29891 X X Green
329.2 8362 16724 18815 20906 22996 25087 27177 29268 31358 X X Pink & GreenX indicates where the listed supply pressure is not sufficient to overcome the opposing bias spring effect.1. The maximum design pressure for size 25 and 50 actuator is 10.3 bar.2. Maximum thrust is 17347 N.3. Maximum thrust is 30700 N.
585C ActuatorProduct Bulletin61.2:585CAugust 2002
15
Table 8. Type 585C Thrust (springless construction)
PISTONTOTAL THRUST FOR TYPE 585C(1)
MAXIMUM ALLOWABLEACTUATOR
PISTONAREA
Operating Pressure, bar(3) MAXIMUM ALLOWABLETHRUSTACTUATOR
SIZEAREA
2.8 3.4 4.1 4.8 5.5 6.2 6.9 7.6 8.6 10.3THRUST
cm2 Force, Newtons(2) Newtons
25 168 4630 5780 6940 8100 9260 10400 11600 12700 14500 17300 17300
50 303 8180 10200 12300 14300 16400 18400 20500 22500 25600 30700 31400
60(3) 358 9880 12300 14800 17300 19800 22200 24700 27200 30900 36900 36900
68(3) 571 15700 19700 23600 27600 31500 35400 39400 43300 49200 55600 55600(4)
80(3) 571 15700 19700 23600 27600 31500 35400 39400 43300 49200 58700 58700
100(3) 842 23200 29000 34800 40600 46400 52200 58000 63900 72600 X 86700
130(3) 1430 39400 49300 59100 69000 78700 88500 98800 108100 X X 111200
ACTUATORPISTON Operating Pressure, psig(3) MAXIMUM ALLOWABLE
ACTUATORSIZE
PISTONAREA 40 50 60 70 80 90 100 110 125 150
MAXIMUM ALLOWABLETHRUST
SIZEInches2 Force, Pounds(2) Pounds
25 26 1040 1300 1560 1820 2080 2340 2600 2860 3250 3900 3900
50 47 1840 2300 2760 3220 3680 4140 4600 5060 5750 6900 7050
60(3) 55.5 2220 2780 3330 3890 4440 5000 5550 6110 6940 8300 8300
68(3) 88.5 3540 4430 5310 6200 7080 7970 8850 9740 11100 12500 12500(4)
80(3) 88.5 3540 4430 5310 6200 7080 7970 8850 9740 11100 13200 13200
100(3) 130.5 5220 6530 7830 9140 10440 11700 13100 14400 16300 19500 19500
130(3) 221.5 8860 11100 13300 15500 17700 19900 22200 24300 X X 25000X indicates where the listed supply pressure will exceed the maximum thrust allowable.1. The maximum design pressure for size 25 through 100 actuators is 10.3 bar (150 psig). Size 68 and 130 actuators are limited to 9.7 and 7.8 bar (140 and 113 psig) respectively.2. The size 25 and 50 data is for the construction without a bias spring.3. Minimum operating pressure for sizes 60-130 actuators is 2.4 bar (35 psig).4. The size 68 actuator with a handwheel is limited to 40000 Newtons (9000 lb) thrust.
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
16
Table 9. Type 585C Long-Stroke Thrust
PISTON PISTON PISTONTOTAL THRUST FOR TYPE 585C LONG-STROKE ACTUATORS(1)
PISTONDIAMETER STROKE
PISTONROD
PISTONAREA
Operating Pressure, barDIAMETER STROKE
RODSIZE
AREA2.8 4.1 5.5 6.9 8.3 9.7 10.3
mm mm mm2 Force, Newtons
127 127 3500 5250 6980 8720 10500 12200 13100
152 182 5030 7560 10100 12600 15100 17600 18900
203Push
323 8940 13400 17900 22400 26800 31300 33500
254Push - - -
507 14000 21000 27900 34900 41900 48900 52500
305 730 20100 30200 40300 50300 60500 70300 75600
356 993 27400 41100 54700 68500 82300 96100 103000
127 111 3060 4580 6140 7650 9210 10700 11500
152Pull 44 5
167 4580 6890 9210 11500 13800 16100 17300
203Pull 44.5
309 8500 12800 17000 21300 25500 29800 31900
254 491 13600 20300 27100 33900 40700 47600 50700
203 293(2) 8050 12100 16100 20200 24200 28200 30200
254Pull 63 5
475(3) 13100 19700 26200 32700 39300 45800 48900
305Pull 63.5
698 19300 28900 38500 48000 57800 67200 72100
356 961 26500 39800 52900 66300 79600 93000 99600
PISTON PISTONROD
PISTON Operating Pressure, psigPISTONDIAMETER STROKE
RODSIZE
PISTONAREA 40 60 80 100 120 140 150
Inches Inches Inches2 Force, Pounds
5 19.6 786 1180 1570 1960 2360 2750 2950
6 28.3 1130 1700 2260 2830 3390 3960 4240
8Push
50.3 2010 3020 4020 5030 6030 7040 7540
10Push - - -
78.5 3140 4710 6280 7850 9420 11000 11800
12 113.1 4520 6790 9050 11300 13600 15800 17000
14 153.9 6160 9240 12300 15400 18500 21600 23100
5 17.2 689 1030 1380 1720 2070 2410 2580
6Pull 1 3/4
25.9 1030 1550 2070 2590 3100 3620 3880
8Pull 1-3/4
47.9 1910 2870 3830 4790 5740 6700 7180
10 76.1 3050 4570 6090 7610 9140 10700 11400
8 45.4(2) 1810 2720 3630 4540 5440 6350 6800
10Pull 2 1/2
73.6(3) 2950 4420 5890 7360 8840 10300 11000
12Pull 2-1/2
108.2 4330 6490 8660 10800 13000 15100 16200
14 149.0 5960 8940 11900 14900 17900 20900 224001. For operating pressures above 10.3 bar (150 psig), consult your Fisher sales office.2. For travels greater than 406 mm (16 inches) with 10.3 to 17.3 bar (150 to 250 psig) operating pressure.3. For travels greater than 406mm (16 inches).
585C ActuatorProduct Bulletin61.2:585CAugust 2002
17
Handwheel SpecificationsSee table 10 for handwheel specifications.
Table 10. Type 585C Handwheel Specifications
ACTUATOR SIZE HANDWHEELMOUNTING
HANDWHEELDIAMETER TURNS PER mm
TRAVEL
MAXIMUM RIMFORCE REQUIRED
HANDWHEELOUTPUT FORCE
HANDWHEELWEIGHTACTUATOR SIZE
MOUNTINGmm
TRAVELNewtons Newtons kg
25Top Mounted
356 0.5 325 12,810 17
50Top-Mounted
482 0.5 445 23,790 20
60 203 0.6 276 40000 28
68 203 0.6 276 40000 30
80 Side-Mounted 432 0.4 423 50000 35
100Side Mounted
432 0.4 623 75600 94
130 432 0.4 623 75600 123
ACTUATOR SIZE HANDWHEELMOUNTING
HANDWHEELDIAMETER TURNS PER INCH
TRAVEL
MAXIMUM RIMFORCE REQUIRED
HANDWHEELOUTPUT FORCE
HANDWHEELWEIGHTACTUATOR SIZE
MOUNTINGInches
TRAVELPounds Pounds Pounds
25Top Mounted
14 12 73 2880 37
50Top-Mounted
19 12 100 5350 45
60 8 16 62 9000 61
68 8 16 62 9000 66
80 Side-Mounted 17 10 95 11250 77
100Side Mounted
17 10 140 17000 208
130 17 10 140 17000 272
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
18
Table 11. Type 585C Dimensions—Size 25 and 50 Actuator with Type 3611 Pneumatic (P/P) Positioner
ACTUATOR SIZEYOKEBOSSSIZE
E H C AR(1) F �Jc L P T X
mm
2554.0 324.4 693.7 205.2 127.0 259.6 355.6 47.8 255.8 19.1 114.3
2571.4 352.3 720.9 205.2 176.3 259.6 355.6 19.8 255.8 23.9 139.3
5071.4 464.3 841.5 257.0 176.3 265.4 482.6 13.7 281.7 23.9 152.4
5090.5 503.4 881.1 257.0 225.6 265.4 482.6 - - - 281.7 35.1 193.5
Inches
252-1/8 12.77 27.31 8.08 5.00 10.22 14.00 1.88 10.07 0.75 4.50
252-13/16 13.87 28.38 8.08 6.94 10.22 14.00 0.78 10.07 0.94 5.50
502-13/16 18.28 33.13 10.12 6.94 10.45 19.00 0.54 11.09 0.94 6.00
503-9/16 19.82 34.69 10.12 8.88 10.45 19.00 - - - 11.09 1.38 7.62
1. Actuator removal clearance
18B5463-A
17B3436-B
H
Figure 13. Type 585C Dimensions—Size 25 and 50 Actuator with Type 3611 Pneumatic (P/P) Positioner (also see table 11)
585C ActuatorProduct Bulletin61.2:585CAugust 2002
19
Table 12. Type 585C Dimensions—Size 25 and 50 Actuator with Type 3621 Electro-Pneumatic (I/P) Positioner
ACTUATOR SIZEYOKE BOSS
SIZEE H C AR(1) F �Jc L P
mm
2554.0 322.1 681.0 205.2 127.0 216.7 355.6 96.0 303.5
2571.4 350.0 720.9 205.2 176.3 216.7 355.6 68.1 303.5
5071.4 462.0 836.4 257.0 176.3 222.5 482.6 62.5 329.4
5090.5 501.1 875.6 257.0 225.6 222.5 482.6 23.4 329.4
Inches
252-1/8 12.68 26.81 8.08 5.00 8.53 14.00 3.78 11.95
252-13/16 13.78 28.38 8.08 6.94 8.53 14.00 2.68 11.95
502-13/16 18.19 32.93 10.12 6.94 8.76 19.00 2.46 12.97
503-9/16 19.73 34.47 10.12 8.88 8.76 19.00 0.92 12.97
1. Actuator removal clearance
17B3435-B
H
18B6671-A
Figure 14. Type 585C Dimensions—Size 25 and 50 Actuator with Type 3621 Electro-Pneumatic (I/P) Positioner (also see table 12)
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
20
Table 13. Type 585C Dimensions—Size 60 to 130 Actuator
ACTUATOR AB
DIAMETERC(1) AR D E
FDIAMETER
ARH
SIZE TRAVEL mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch
2 462 18.2 267 10.5 305 12.0 226 8.9 734 28.9 206 8.1 203 8.0 273 10.8
60 4 564 22.2 267 10.5 305 12.0 226 8.9 785 30.9 206 8.1 203 8.0 273 10.8608 782 30.8 267 10.5 305 12.0 232 9.1 1074 42.3 206 8.1 356 14.0 279 11.0
2 597 23.5 325 12.8 330 13.0 226 8.9 853 33.6 206 8.1 203 8.0 273 10.8
68 4 729 28.7 325 12.8 330 13.0 226 8.9 853 33.6 206 8.1 203 8.0 273 10.8688 828 32.6 325 12.8 330 13.0 232 9.1 1143 45.0 206 8.1 356 14.0 279 11.0
804 714 28.1 325 12.8 330 13.0 295 11.6 1245 49.0 305 12 432 17.0 295 11.6
808 965 38.0 325 12.8 330 13.0 295 11.6 1344 52.9 305 12 432 17.0 295 11.6
1004 714 28.1 381 15.0 361 14.2 321 12.6 1245 49.0 305 12 432 17.0 321 12.6
1008 958 37.7 381 15.0 361 14.2 321 12.6 1346 53.0 305 12 432 17.0 321 12.6
1304 833 32.8 483 19.0 411 16.2 321 12.6 1410 55.5 305 12 432 17.0 321 12.6
1308 1006 39.6 483 19.0 411 16.2 321 12.6 1725 67.9 305 12 432 17.0 321 12.6
1. The “C” dimension shown is for FIELDVUE DVC5000 or DVC6000 digital valve controllers. Add 38.1 mm (1.5 inches) to this dimension for Type 3620JP positioners.Subtract 12.7 mm (0.5 inches) to this dimension for Type 3610JP positioners.
����������������������� ��� ��������� ��
���������� ���������
�������������������������������
� B
A
C
� F
E
D
A
C
� B
1
11 THE “C” DIMENSION LISTED IN THE TABLE IS
FOR THE ACTUATOR WITH THE FIELDVUEDIGITAL VALVE CONTROLLER. ADD TO THISDIMENSION FOR TYPE 3620JP POSITIONERS.SUBTRACT FROM THIS DIMENSION FOR TYPE3610JP POSITIONERS. REFER TO THE FOOT-NOTE IN THE TABLE.
AR
ARH
Figure 15. Type 585C Dimensions—Size 60 to 130 Actuator (also see table 13)
585C ActuatorProduct Bulletin61.2:585CAugust 2002
21
Table 14. Type 585C Long Stroke Dimensions (FabricatedYoke)
DIMENSION
TRAVEL B E(w/o Handwheel)
E(w/ Handwheel)
mm In. mm In. mm In. mm In.
229254279305
9101112
762762762762
30303030
1217124212671293
47.948.949.950.9
1722174817731798
67.868.869.870.8
330356381406
13141516
864864864864
34343434
1420144514711496
55.956.957.958.9
2027205220782103
79.880.881.882.8
432457483508
17181920
965965965965
38383838
1623164816741699
63.964.965.966.9
2332235723832408
91.892.893.894.8
533559584610
21222324
1067106710671067
42424242
1826185218771902
71.972.973.974.9
2637266226872713
103.8104.8105.8106.8
Table 15. Type 585C Long Stroke Dimensions (FabricatedYoke)CylinderDiametermm (Inch)
127(5)
152(6)
203(8)
254(10)
305(12)
356(14)
E DimensionCorrectionFactormm (Inch)
84(3.3)
69(2.7)
82(3.2)
46(1.8)
33(1.3)
0(0)
194(7.62)MAX
B
191(7.50)
54(2.12)
324(12.75)
B2522 / IL
42A4726-A / IL
52A4727-A / IL
E
B
E
1
1
������ ��� ��������!����������
������ ��� ��������!������������������������
NOTE:
THE E DIMENSIONS SHOWN ARE FOR A 356 mm (14-INCH)
DIAMETER PISTON. THE E DIMENSION FOR SMALLER PISTONS
WILL BE SLIGHTLY LESS. SUBTRACT THE FOLLOWING VALUE
FROM THE E DIMENSION FOR SMALLER CYLINDERS.
1
Figure 16. Type 585C Long Stroke Dimensions (Fabricated Yoke) (also see tables 14 and 15)
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
22
Specifications - Type 585C Actuators (sizes 25-130)Operating Pressure
Sizes 25-50:Maximum Allowable: 10.3 bar (150 psig)Minimum Recommended: 1.4 bar (20 psig)Sizes 60-130:Maximum Allowable: See table 8.Minimum Recommended: 2.4 bar (35 psig)
Travel
See table 2
Thrust Capabilities
See tables 4, 5, 6, 7, and 8
Stroking Speeds
Varies with actuator size, actuator spring, travel,and supply pressure. If stroking speed is critical,consult your Fisher sales office
Piston Area
See table 8
Cylinder Volumetric Displacement
See table 2
Operative Temperature Limits
For All Sizes:With Nitrile O-Rings: –50 to 80�C (–58 to 175�F),standardWith Fluoroelastomer O-Rings: –18 to 150�C (0 to 300�F), optional
Yoke Boss and Valve Stem Diameters
See table 3
Pressure Connections
Size 25:� 1/4 inch NPT female (standard), or � 3/8 inchNPT female (optional)
Sizes 50-60:� 1/4 inch NPT female (standard), or � 1/2 inchNPT female (optional)Sizes 68-130:� 1/2 inch NPT female (standard)
Instrument Mounting
The Type 585C actuator has NAMUR mountingcapability on sizes 25 through 130.
Construction Materials
Part Material
Yoke Ductile Iron
Piston Aluminum
Cylinder Aluminum
Bolting and Fasteners NCF (non-corroding finish)
Springs (sizes 25 & 50 only) Alloy Steel
O-RingsNitrile (std), Fluoroelastomer, orEPDM
Actuator Stem Chrome-plated Steel
Stem Connection Stainless Steel
Travel Indicator Scale Stainless Steel
Paint Polyester Powder
Actuator Stem(sizes 60-130 only)
S41600 (416) SST, Chrome Plate
Cylinder Seal Bushings(sizes 60-130 only)
Brass
Approximate Weights (less positioner andhandwheel)
Size 25:2-1/8 inch yoke boss, 7 kg (16 pounds)2-13/16 inch yoke boss, 8 kg (17 pounds)Size 50:2-13/16 inch yoke boss, 20 kg (45 pounds)3-9/16 inch yoke boss, 22 kg (48 pounds)Size 60: 31 kg (68 pounds)Size 68: 54 kg (120 pounds)Size 80: 102 kg (225 pounds)Size 100: 113 kg (250 pounds)Size 130: 188 kg (415 pounds)
- continued -
585C ActuatorProduct Bulletin61.2:585CAugust 2002
23
Specifications - Type 585C Actuators (sizes 25-130) (continued)Options
Sizes 25 and 50:� Top-mounted handwheel, see figures 13 and14 and table 10.� Cylinder bypass valve � Limit switches � 4200Series position transmitterSizes 60-80:� Side-mounted handwheel
Sizes 60-130:� FIELDVUE� mounting options� 377 Series trip valve system to fail actuator� up or � down or � lock in last position� Type 304 electrical valve stem position switch� Micro-Switch limit switches
DimensionsSee figures 13 and 14
Specifications - Type 585C Long-Stroke (Fabricated Yoke) ActuatorsCylinder Pressure
Minimum Recommended: For valves with lowthrust requirements—2.4 bar (35 psig); for allother valves—3.4 bar (50 psig)Maximum Allowable: 127 mm (5-inch) to 305mm (12-inch) Diameter Cylinders—17.2 bar (250psig) unless limited by maximum allowable supplypressure of positioner or switching devices; 356mm (14-inch) diameter cylinder—13.8 bar (200psig) unless limited by maximum allowable supplypressure of positioner or switching device
Travel Information
All Types: 229 mm (9 inches) through 610 mm(24 inches) in 25 mm (1-inch) increments asshown in figure 16.Travel Ratio for Handwheel Construction: 10complete revolutions of wheel moves stem 25 mm(1 inch)
Thrust Information
See table 9
Operative Ambient Temperature(2)
For All Sizes:With Nitrile O-Rings: –50 to 80�C (–58 to 175�F),standard
With Fluoroelastomer O-Rings: –18 to 150�C(0 to 300�F), optional
Piston Diameters and Areas
See table 9
Yoke Boss and Valve Stem Diameters
See table 3
Pressure Connections
Standard is 1/4-inch NPT. For larger sizes,consult your sales office
Construction Materials
Part Material
Cylinder Body: 127 mm through 356 mm(5-inch through 14-inch)
Steel, chrome plated
Piston Rod Steel, chrome plated
Yoke Structural Steel
Options
� High temperature piston seals to 177�C(350�F), � 377 Series trip valves to fail actuatorup, down, or lock in last position, � Limitswitches, � Side-mounted handwheel
Dimensions
See figure 161. Scfh - Standard cubic feet per hour (60�F and 14.7 psia); normal m3/hr - normal cubic meters per hour (0�C and 1.01325 bar, absolute)2. These terms are defined in ANSI/ISA S51.1
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
24
Specifications - DVC6000 Series Digital Valve Controllers (refer to bulletin 62.1:DVC6000 for complete DVC6000 information)
Available Configurations
DVC6010: Sliding-stem applications with travelsof 101.6 mm (4 inches) or lessDVC6020: Sliding-stem applications with greaterthan 101.6 mm (4 inches) travel
Input Signal(1)
Point-to-Point:Analog Input Signal: 4–20 mA dc, nominal; splitranging availableMinimum Voltage Available at InstrumentTerminals must be 10.5 volts dc for analogcontrol, 11 volts dc for HART communication (seeinstrument instruction manual for details)Minimum Control Current: 4.0 mAMinimum Current w/o Microprocessor Restart: 3.5mAMaximum Voltage: 30 volts dcOvercurrent Protection: Input circuitry limitscurrent to prevent internal damageReverse Polarity Protection: No damage occursfrom reversal of loop current
Multi-drop:Instrument Power: 11 to 30 volts dc atapproximately 8 mAReverse Polarity Protection: No damage occursfrom reversal of loop current
Output Signal(1)
Pneumatic signal as required by the actuator, upto full supply pressureMinimum Span: 0.4 bar (6 psig)Maximum Span: 9.5 bar (140 psig)Action: � Double, � Single Direct, and � SingleReverse
Supply Pressure
Minimum Recommended: 0.3 bar (5 psig)higher than maximum actuator requirementsMaximum: 10.3 bar (150 psig) or maximumpressure rating of the actuator, whichever is lower
Steady-State Air Consumption(1)(2)(3)
At 1.4 bar (20 psig) supply pressure: Less than0.38 normal m3/hr (14 scfh)
At 5.5 bar (80 psig) supply pressure: Less than1.3 normal m3/hr (47 scfh)
Maximum Output Capacity(2)(3)
At 1.4 bar (20 psig) supply pressure: 10.7normal m3/hr (400 scfh)At 5.5 bar (80 psig) supply pressure: 33.2normal m3/hr (1240 scfh)
Independent Linearity(1)(4)
+/–0.5% of output span
Electromagnetic Interference (EMI)
These instruments have the CE mark inaccordance with the ElectromagneticCompatibility (EMC) Directive. They meet therequirements of EN61326-1 (emissions for lightindustry, immunity for industrial environment).
Electrical Classification
Hazardous Area: Approvals are pending fromcertifying agencies. Refer to Hazardous Areabulletins.Electrical Housing: Designed to meet NEMA 4X,IEC 60529 IP65 (approvals pending)
Connections
Supply Pressure: 1/4-inch NPT female andintegral pad for mounting 67CFR regulatorOutput Pressure: 1/4-inch NPT femaleTubing: 3/8-inch metal, recommendedVent (pipe-away): 1/4-inch NPT femaleElectrical: 1/2-inch NPT female conduitconnection, M20 adaptor optional
Operating Ambient Temperature Limits
–40 to 85�C (–40 to 185�F)
Construction Materials
Housing, module base and terminal box: ANSIB360.0 low copper aluminum alloyCover: ValoxElastomers: � Nitrile (standard), or� Fluoroelastomer (optional)
- continued -
585C ActuatorProduct Bulletin61.2:585CAugust 2002
25
Specifications - DVC6000 Series Digital Valve Controllers (refer to bulletin 62.1:DVC6000 for complete DVC6000 information) (continued)
Stem Travel
DVC6010: 0 to 102 mm (4 inches) maximum0 to 9.5 mm (3/8 inches) minimumDVC6020: 0 to 606 mm (23-7/8 inches) maximum
Mounting
Designed for direct actuator mounting. Forweatherproof housing capability, the instrumentmust be mounted upright to allow the vent todrain.
Weight
3.5 kg (7.7 lbs)
Options
� Supply and output pressure gauges or � tirevalves, � integral mounted filter regulator,� Fluoroelastomer O-rings
1. These terms are defined in ISA Standard S51.1.2. Normal m3/hr - Normal cubic meters per hour at 0�C and 1.01325 bar, absolute; Scfh - Standard cubic feet per hour at 60�F and 14.7 psia.3. Values at 1.4 bar (20 psig) based on a single-acting direct relay; values at 5.5 bar (80 psig) based on double-acting relay.4. Not applicable for Type DVC6020 digital valve controllers in long-stroke applications.
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
26
Specifications - 3600 Series PositionersAvailable Configurations
� Pneumatic (P/P) Positioner: Type 3610JPand 3611JP� Electro-Pneumatic (I/P) Positioner: Type3620JP and 3621JP
Application by Size
� Size 25 and 50: Type 3611JP and 3621JP� Size 60-130 and Type 585C Long-Stroke:Type 3610JP and 3620JP
Input Signal(1)
Type 3610JP and 3611JP:Standard: � 0.2 to 1.0 bar (3 to 15 psig), � 0.4 to2.0 bar (6 to 30 psig), or � split range, see table16.Adjustable: Zero is adjustable from 0.07 to 1.5 bar(1 to 22 psig) for standard valve travels. Span isadjustable from 0.2 to 2.0 bar (3.2 to 28.8 psi) forstandard valve travels.Type 3620JP and 3621JP:4 to 20 mA dc constant current with 30 V dcmaximum compliance voltage. Minimum terminalvoltage is 2.4 V dc at 20 mA. Split range is alsoavailable, see table 16.
Equivalent Circuit
Type 3620JP and 3621JP: 120 ohms shunted bythree 5.6 V zener diodes
Output Signal(1)
Pneumatic pressure as required by the actuatorup to full supply pressureAction(2): Field-reversible between � direct and� reverse within the pneumatic positioner
Typical Performance (Refer to table 17 for typical performance forType 3611JP and 3621JP Positioners)
Independent Linearity(1)
Direct-Acting Type 3610JP and 3620JP: ±1.25%of output spanReverse-Acting Type 3610JP and 3620JP: ±0.5%of output spanHysteresis(1)
Type 3610JP: 0.5% of output spanType 3620JP: 0.6% of output spanDeadband(1): 0.1% of input spanElectromagnetic Interference (EMI)(1) for3620JP and 3621JP:When tested per IEC 60801-3 (1984),
steady-state deviation is less than +/–1% at anelectromagnetic field strength of 30 V/m from 20to 1000 MHz. Positioner is tested with cover onand with external wiring in rigid metal conduit.
Maximum Supply Air Demand(3)
Type 3610JP, 3620JP, 3611JP, and 3621JP:5.2 Bar (75 Psig) Supply: 37 normal m3/hour(1380 scfh)6.9 Bar (100 Psig) Supply: 46 normal m3/hour(1700 scfh)
Supply Pressure(1)
Minimum Recommended: 0.3 bar (5 psig) aboveactuator requirementMaximum: 10.3 bar (150 psig) or maximumpressure rating of the actuator, whichever is lower
Steady-State Air Consumption(3)
Type 3610JP: 0.64 normal m3/hour (24 scfh) at6.9 bar (100 psig) supply pressureType 3620JP: 0.93 normal m3/hour (35 scfh) at6.9 bar (100 psig) supply pressure
Operative Temperature Limits(1)
–40 to 82�C (–40 to 180�F)
Housing Classification for 3620JP and 3621JP
NEMA 3, IEC 60529 IP54; Instrument should bemounted with vent on side or bottom to meetweatherproofing classification
Electrical Classification for 3620JP and 3621JP
Refer to the Hazardous Area Classificationbulletin for specific approvals
Construction Materials
All Positioners:Case: Low copper aluminum alloyCover: Polyester plasticFeedback Lever: Stainless steelRange Spring: Zinc-plated steelInput Module and Relay Diaphragms: Nitrile andDacronRelay Valve Plugs and Seats: Stainless steelTubing: Copper (standard)Fittings: Brass (standard)Gauges: Chrome-plated brass connection withplastic caseType 3620JP and 3621JP:Housing and Cap: Low copper aluminum alloy
-continued-
585C ActuatorProduct Bulletin61.2:585CAugust 2002
27
Specifications—3600 Series Positioners (continued)Pressure Connections
1/4-inch NPT female
Conduit Connection for Type 3620JP and 3621JP
1/2-inch NPT female (standard), M20 or PG13adaptor (optional)
OptionsType 3610JP, 3611JP, 3620JP, and 3621JP:� Supply pressure gauge, � tire valves, or� plugs
Approximate Weight3610JP and 3611JP: 2.5 kg (5.6 pounds)3620JP and 3621JP: 3.6 kg (8.0 pounds)
1. These terms are defined in ISA Standard S51.12. For direct action, an increasing input signal extends the actuator rod. For reverse action, an increasing input signal retracts the actuator rod.3. Normal m3/hr - normal cubic meters per hour (0�C and 1.01325 bar absolute). Scfh - standard cubic feet per hour (60�F and 14.7 psia).
Table 16. Split-Ranging CapabilitiesTYPE 3610JP/3611JP PNEUMATIC (P/P) POSITIONER
Split0.2 to 1.0 Bar (3 to 15 Psig) Input Signal 0.4 to 2.0 Bar (6 to 30 Psig) Input Signal
SplitBar Psig Bar Psig
Two-way0.2 to 0.60.6 to 1.0
3 to 99 to 15
0.4 to 1.21.2 to 2.0
6 to 1818 to 30
Three-way0.2 to 0.50.5 to 0.70.7 to 1.0
3 to 77 to 11
11 to 15
0.4 to 0.90.9 to 1.51.5 to 2.0
6 to 1414 to 2222 to 30
TYPE 3620JP/3621JP ELECTRO-PNEUMATIC (I/P) POSITIONER(1)
Split 4 to 20 Milliampere Input Signal
Two-way4 to 12
12 to 20
Three-way4 to 9.3
9.3 to 14.714.7 to 20
1. Hazardous area approvals are not available with split range applications.
Table 17. Typical Performance Specifications(1) for Type 3611JP and Type 3621JP Positioners with Size 25 and 50 ActuatorsCharacteristic Size 25 Actuator(8) Size 50 Actuator(8)
Deadband(1,2) 0.1% of input span 0.1% of input span
Step Response(1,3,5) 0.3 seconds 0.3 seconds
Steady-State Air Consumption(2,4,7) 0.64 normal m3/hr (24 scfh) 0.64 normal m3/hr (24 scfh)
Hysteresis(3) 0.5% of output span 0.5% of output span
Terminal-Based Linearity(2,6) 1% of output span 1% of output span
Frequency Response(1,2) (–6 dB) 2 Hz 2 Hz
Supply Pressure Sensitivity 10% change in supply pressure changes the actuator stem position less than 0.1%1. Performance tests are based on 6.9 bar (100 psig) supply pressure and lightest actuator springs. Performance will vary with other pressures and springs.2. These terms are defined in ISA Standard S51.1.3. Step response is the time for the actuator to reach 63 percent of expected travel after a 10 percent step change in input signal.4. At 6.9 bar (100 psig) supply pressure. Scfh—standard cubic feet per hour (60�F and 14.7 psia). Normal m3/hr-cubic meters per hour (0�C and 1.01325 bar).5. Type 3621JP positioner step response equals 0.4 seconds.6. Type 3621JP positioner terminal-based linearity equals +/–2.25%.7. Type 3621JP positioner steady-state air consumption equals 0.93 normal m3/hr (35 scfh).8. Size 25 and 50 actuators tested with appropriate parallel flexure (key 179).
585C ActuatorProduct Bulletin
61.2:585CAugust 2002
28
Fisher Marshalltown, Iowa 50158 USACernay 68700 France Sao Paulo 05424 BrazilSingapore 128461
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy,they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their useor applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Fisher does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Fisher product remains solely with the purchaser and end-user.
�Fisher Controls International, Inc. 1994, 2002; All Rights Reserved Printed in USA
FIELDVUE and Fisher are marks owned by Fisher Controls International, Inc., a business of Emerson Process Management. The Emersonlogo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners.
Emerson Process Management
www.Fisher.com