tuv listed led flood lights - eneltec-led.com · tuv listed led flood lights. tuv listed led flood...

7
LED FLOODLIGHTS LM-80 LED DRIVER inside LED DRIVER TUV Listed LED Flood Lights

Upload: trinhlien

Post on 23-Apr-2018

255 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: tuv listed led flood lights - eneltec-led.com · TUV Listed LED Flood Lights. TUV Listed LED FLOOD LIGHTS ... TM-21 Lumen Maintenance (54,000 Hours) ... 7.9” 370 mm L

LED FLOODLIGHTS

LM-80

LED DRIVER inside

LED DRIVER

TUV ListedLED Flood Lights

Page 2: tuv listed led flood lights - eneltec-led.com · TUV Listed LED Flood Lights. TUV Listed LED FLOOD LIGHTS ... TM-21 Lumen Maintenance (54,000 Hours) ... 7.9” 370 mm L

TUV ListedLED FLOOD LIGHTS PRODUCT CATALOG

www.eneltec-led.com | [email protected]

LED DRIVER (Two op ons)

High-end Mean Well HLG SeriesLED driver, op mal stability, performance and lifespan.

+ NON-DIMMABLE

+ DIMMABLE

High-end programmableLED driver, integrate dimming func on and 6KV /10KV surge protec on. Provide excellentperformance and lifespan.

Cylindrical edge design, avoid cut risk.Black & Silver Color Modules.Overall stainless steel screws adopted.

LED MODULEExquisite design with powerfulthermal dissipa on and IP67waterproof performance.

LED LUMINOUS SOURCE

The ENELTEC TUV Listed LED floodlights areusing LUMILEDS® LUXEON 3030 2D luminous source, providing excellent lumen output, long-las ng stability and splendid sight.

The ENELTEC TUV Listed LED floodlights havea high luminous efficiency and be er service life. Provide 7 years warranty on luminaire.

Overview

Color Op onsSilver Gray

illumination grade LED light source.

XTREME LUMINAIRE DESIGNReasonable heat sink design, notonly keep ven la on but alsoavoid lacera on.

Gaps between each module areincreased heat dissipa on speedand solved the problem of dustdeposi on.

Page 3: tuv listed led flood lights - eneltec-led.com · TUV Listed LED Flood Lights. TUV Listed LED FLOOD LIGHTS ... TM-21 Lumen Maintenance (54,000 Hours) ... 7.9” 370 mm L

TUV ListedLED FLOOD LIGHTS PRODUCT CATALOG

www.eneltec-led.com | [email protected]

DETAILED FEATURES

Professional lens design with 60°, 90°and 110° op onal.

Use M16 waterproof connector, avoid hard power damage.

Op cs

Use waterproof connector for internalwiring, safe, convenient & fast.

Innova ve pluggable connector,clean & efficient.

UL standard connec on.

A special taylor-made packagingdesigned to guarantee the highestprotec on of the lamp.

30°

60°

180°

C90 - C270C0 - C180 unit: cd

120°

60°

90° 90°

120°

30° 30°

60°

180°

C90 - C270 dc :tinu081C - 0C

120°

60°

90° 90°

120°

30°

30°

60°

180°

C90 - C270 dc :tinu081C - 0C

120°

60°

90° 90°

120°

30°

Full aluminium enhanced luminaire bracket supports flexible angle adjustment.Designed for a variety of applica ons

With a non-corrosive material, not only exquisite appearance, but also no corrosion concerns.

Applica ons: Billboard| Area Ligh ng | Architecture Ligh ng | Landscape Ligh ng

Lens code: 60º

Applica ons: Billboard| Area Ligh ng | Architecture Ligh ng | Landscape Ligh ng

Lens code: 110º

Applica ons: Billboard| Area Ligh ng | Architecture Ligh ng | Landscape Ligh ng

Lens code: 90º

60º

Reference Only

110º

Reference Only

90º

Reference Only

Page 4: tuv listed led flood lights - eneltec-led.com · TUV Listed LED Flood Lights. TUV Listed LED FLOOD LIGHTS ... TM-21 Lumen Maintenance (54,000 Hours) ... 7.9” 370 mm L

TUV ListedLED FLOOD LIGHTS PRODUCT CATALOG

www.eneltec-led.com | [email protected]

LUMEN MAINTENANCE

AmbientTemperature

TM-21 Lumen Maintenance(54,000 Hours)

Theore cal L70(Hours)

25 ºC 78.05%

78.99%

78.49%

40 ºC

50 ºC 75,000

79,000

82,000

PACKAGING DATA

DIMENSION DATA

Number ofModules 54321

“L” Length 166 mm6.5”

239 mm9.4”

312 mm12.3”

385 mm15.2”

458 mm18.0”

“H” Height 190 mm7.5”

227 mm8.9”

263 mm10.4”

300 mm11.8”

336 mm13.2”

Weight 2.4 kg5.3 lbs.

3.6 kg7.9 lbs.

4.6 kg10.1 lbs.

5.4 kg11.9 lbs.

6.3 kg13.9 lbs.

200 mm7.9”

L

370 mm

14.6”

Number ofModules 54321

“L” Length 285 mm11.2”

355 mm14.0”

430 mm17.0”

505 mm19.9”

580 mm22.8”

Weight 3.1 kg6.8 lbs.

4.4 kg9.7 lbs.

5.4 kg11.9 lbs.

6.3 kg13.9 lbs.

7.2 kg15.9 lbs.

270mm10.6inches

H

L

Product

Nominal Wa age

LED Working Current

Number of Modules

Input Voltage

Dimming

LED Brand

Driver Brand

Max. Current @ 120V

Max. Current @208V

Max. Current @240V

Max. Current @277V

Opera ng Temperature

Power Factor (PF)

THD

Lumen Output (+/- 5%)

Luminaire efficacy

Op c

CRI

CCT

Ra ng

Material

Installa on

Accessories (Op onal)

Shell Color

Lumen Maintenance

Cer �ca ons

Packaging Type

5200 lm

130 lm /w

10400 lm

130 lm /w

15600 lm

130 lm /w

20800 lm

130 lm /w

26000 lm

130 lm /w

0.41A

0.24A

0.21A

0.18A

0.82A

0.47A

0.41A

0.36A

1.23A

0.71A

0.62A

0.53A

1.65A

0.95A

0.82A

0.71A

2.06A

1.19A

1.03A

0.89A

100-240V /277V AC 50 /60Hz

0-5V, 0-10V, PWM, Timer

Philips Lumileds 3030

Non-dimmable: MeanWell HLG Driver | Dimmable: Inventronics Driver

-40 ºC to +50 ºC

>0.95

<20%

60°, 90°, 110°

>70

4000K (Nature White), 5000K (Pure White), 5700K (Cool White)

IP66, IK10

Housing: Die-cast aluminum; Heat sink: Stretched Aluminium Alloy; Lens: PC

Installa on angle can be adjustable

Mo on sensor

Silver (RAL9022) , other RAL colors available on request

> 75,000 hours-L₇₀ at 25 ºC

CE, ROHS, LM80, ISO9001, ISO14001

1 unit /ctn.

40W

95 mA

80W

100 mA

120W

100 mA

160W

100 mA

200W

100 mA

ENFL-40W-04TUVH4 ENFL-80W-04TUVH4

1

0-10V

5432

ENFL-120W-04TUVH4 ENFL-160W-04TUVH4 ENFL-200W-04TUVH4

Page 5: tuv listed led flood lights - eneltec-led.com · TUV Listed LED Flood Lights. TUV Listed LED FLOOD LIGHTS ... TM-21 Lumen Maintenance (54,000 Hours) ... 7.9” 370 mm L

TUV ListedLED FLOOD LIGHTS PRODUCT CATALOG

www.eneltec-led.com | [email protected]

Product

Nominal Wa age

LED Working Current

Number of Modules

Input Voltage

Dimming

LED Brand

Driver Brand

Max. Current @ 120V

Max. Current @208V

Max. Current @240V

Max. Current @277V

Opera ng Temperature

Power Factor (PF)

THD

Lumen Output (+/- 5%)

Luminaire efficacy

Op c

CRI

CCT

Ra ng

Material

Installa on

Accessories (Op onal)

Shell Color

Lumen Maintenance

Cer �ca ons

Packaging Type

100-240V /277V AC 50 /60Hz

1-10V, PWM, Resistance, Timer

Philips Lumileds 3030

MeanWell Driver

-40 ºC to +50 ºC

>0.95

<20%

60°, 90°, 110°

>70

4000K (Nature White), 5000K (Pure White), 5700K (Cool White)

IP66, IK10

Housing: Die-cast aluminum; Heat sink: Stretched Aluminium Alloy; Lens: PC

Installa on angle can be adjustable

Mo on sensor

Silver (RAL9022) , other RAL colors available on request

> 75,000 hours-L₇₀ at 25 ºC

CE, ROHS, ISO9001, ISO14001, LM80

1 unit /ctn.

ENFL-50W-04TUVH5

54321

50W

115 mA

100W

120 mA

150W

120 mA

200W

120 mA

240W

120 mA

6250 lm

125 lm /w

12500 lm

125 lm /w

18750 lm

125 lm /w

25000 lm

125 lm /w

30000 lm

125 lm /w

0.51A

0.30A

0.26A

0.22A

1.03A

0.59A

0.51A

0.45A

1.54A

0.89A

0.77A

0.67A

2.06A

1.19A

1.03A

0.89A

2.57A

1.48A

1.29A

1.11A

LUMEN MAINTENANCE

AmbientTemperature

TM-21 Lumen Maintenance(54,000 Hours)

Theore cal L70(Hours)

25 ºC 78.05%

78.99%

78.49%

40 ºC

50 º 000,57C

79,000

82,000

PACKAGING DATA

DIMENSION DATA

Number ofModules 54321

“L” Length 166 mm6.5”

239 mm9.4”

312 mm12.3”

385 mm15.2”

458 mm18.0”

“H” Height 190 mm7.5”

227 mm8.9”

263 mm10.4”

300 mm11.8”

336 mm13.2”

Weight 2.4 kg5.3 lbs.

3.6 kg7.9 lbs.

4.6 kg10.1 lbs.

5.4 kg11.9 lbs.

6.3 kg13.9 lbs.

200 mm7.9”

L

370 mm

14.6”

Number ofModules 54321

“L” Length 285 mm11.2”

355 mm14.0”

430 mm17.0”

505 mm19.9”

580 mm22.8”

Weight 3.1 kg6.8 lbs.

4.4 kg9.7 lbs.

5.4 kg11.9 lbs.

6.3 kg13.9 lbs.

7.2 kg15.9 lbs.

270mm10.6inches

H

L

0-10V

ENFL-100W-04TUVH5 ENFL-150W-04TUVH5 ENFL-200W-04TUVH5 ENFL-240W-04TUVH5

Page 6: tuv listed led flood lights - eneltec-led.com · TUV Listed LED Flood Lights. TUV Listed LED FLOOD LIGHTS ... TM-21 Lumen Maintenance (54,000 Hours) ... 7.9” 370 mm L

TUV ListedLED FLOOD LIGHTS PRODUCT CATALOG

www.eneltec-led.com | [email protected]

DimmingMul ple dimming func ons are integrated (0-5V DC or 0-10V DC or PWM Signal or Timer).

0-5V Dimming†

InventronicsLED Driver

L V+(BRN)

V-(BLU)

Vaux(BLK/WHT)

Dim+(PUR)

Dim-(GRY)

N

G0-5VDimmer

Implementa on 1: Posi ve logic Implementa on 2: Nega ve logic

Notes:

The recommended implementa on of the dimming control is provided below.

Vac

The dimmer can also be replaced by an ac ve 0-5V voltage source signal or passive components like resistors and zener.Do NOT connect Dim− to the output V− or V+, otherwise the driver will not work properly.If 0-5V dimming is not used, Dim + should be open.When 0-5V nega ve logic dimming mode and Dim+ is open, the driver will output maximum current.

1.2.3.4.

0-10V Dimming†

Implementa on 3: Posi ve logic Implementa on 4: Nega ve logic

Notes:The dimmer can also be replaced by an ac ve 0-10V voltage source signal or passive components like resistors and zener.Do NOT connect Dim− to the output V− or V+, otherwise the driver will not work properly.If 0-10V dimming is not used, Dim + should be open.When 0-10V nega ve logic dimming mode and Dim+ is open, the driver will output maximum current.

1.2.3.4.

InventronicsLED Driver

L V+(BRN)

V-(BLU)

Vaux(BLK/WHT)

Dim+(PUR)

Dim-(GRY)

N

G0(1)-10VDimmer

The recommended implementa on of the dimming control is provided below.

PWM Dimming†

Notes:Do NOT connect Dim− to the output V− or V+, otherwise the driver will not work properly.If PWM dimming is not used, Dim + should be open.When PWM nega ve logic dimming mode and Dim+ is open, the driver will output maximum current.

1.2.3.

The recommended implementa on of the dimming control is provided below.

Implementa on 5: Posi ve logic Implementa on 6: Nega ve logic

InventronicsLED Driver

L V+(BRN)

V-(BLU)

Vaux(BLK/WHT)

Dim+(PUR)

Dim-(GRY)

N

GPWMSignal

Page 7: tuv listed led flood lights - eneltec-led.com · TUV Listed LED Flood Lights. TUV Listed LED FLOOD LIGHTS ... TM-21 Lumen Maintenance (54,000 Hours) ... 7.9” 370 mm L

TUV ListedLED FLOOD LIGHTS PRODUCT CATALOG

www.eneltec-led.com | [email protected]

Time Dimming†

The product (LED ligh ng equipment, electrical, electronic equipment) should not be placed in municipal waste. Check local regula ons for disposal of electronic products.

Features and specifica ons are subject to change without no ce.The product color may be different with actual due to discrepancy of camera or screen se ngs.

AFTER-SALE SERVICEENELTEC warrants our hardware product against defects in materials and workmanship under normal use for a period of SEVEN (7) YEAR from the date of purchase. ENELTEC provides free repair or replacement within warranty period. ENELTEC shall charge against defeats by abnormal storage, usage, connection or change the structure or any components of the product.

*Damage by thunder stroke over 10KV(L,N to FG) /6KV(L to N) will not covered by warranty based on IEC61000-4-5.

Notes:Time Dimming is required to program by computer (Microso Windows).Set the ming curve by pulling the sliders.

1.2.

(Se ng Window)