turbine ventilators - francis refrigeration commercial and
TRANSCRIPT
Why turbine ventilation?
Mounted to the roof, turbine ventilators extract hot, stale and polluted indoor air. This allows cool, fresh air to enter the
building from outside. Turbine ventilators keep indoor environments cooler and healthier; they use no electricity and turn
using the wind and natural convection. Turbovent’s range of turbine ventilators are made from the best quality materials
to the highest international standards.
General features
Turbovent has successfully supplied hundreds of thousands of turbine ventilators since 1990 to almost every type of build-
ing, both with and without ceilings, to homes, schools, churches, shops, warehouses and factories.
• Turbine ventilators are able to withstand wind speeds of up to 220km/h, yet will turn even in the complete absence
of wind
• can be fitted to almost any roof up to a 45° pitch
• require no maintenance
• are completely silent
• are waterproof
• keep dust and pollutants from coming into the building
• are SABS approved
• can be used in confined spaces such as containers and vehicles
• can be used to enhance the effectiveness of chimney flues.
Benefi ts
• Cooling and ventilation: the primary benefi t of turbine ventilators is that they effi ciently remove hot, stale and polluted air
from buildings in which attic-air can be heated up to 65°, this allows the air to be replaced with cool fresh air from outdoors.
• Cost effective: turbine ventilators require no maintenance and no electricity to run.
• In winter, ventilation removes moisture-laden air; too much moisture is known to deteriorate structures and cause mould to
grow in attic spaces.
• Reducing a building’s heat load will assist in reducing air-conditioning bills in summer.
• The steady fl ow of air through ventilation clears out airborne contaminants and replenishes oxygen levels in the air, creating a fresh
and clean environment.
Turbovent has the largest range
of natural turbine ventilators in
Southern Africa - ideal for home
and industry use.
TURBINE VENTILATORS
How
turb
ine
ventila
tion w
ork
s
Turb
ine v
entila
tors
harn
ess
the p
ow
er
of
the w
ind t
o d
rive
a c
entrifugal tu
rbin
e d
om
e t
hat
create
s a v
acu
um
to p
ull a
ir
out of a b
uildin
g. Ev
en in the a
bse
nce
of w
ind, tu
rbin
es
will sp
in a
nd a
llow
hot air to ris
e o
ut of th
e b
uildin
g; th
is is
the
natu
ral pro
cess
of co
nve
ctio
n. Tu
rbin
e v
entila
tors
keep d
ust
out of buildin
gs
beca
use
the a
ir is
blo
wn o
ut of th
e turb
ine
by
the s
pin
nin
g m
otion o
f th
e turb
ine b
lades.
Wate
r is
als
o k
ept out of th
e b
uildin
g; eve
n in the h
eavi
est
rain
sto
rms,
the
speci
ally
desi
gned g
roove
s on the turb
ine repel w
ate
r aw
ay
from
the turb
ine.
How
to s
elec
t a
turb
ine
ventila
tor?
Turb
ove
nt’s
ext
ensi
ve range o
f tu
rbin
es
allow
you to fi n
d the p
erfect
turb
ine for yo
ur applica
tion. Hig
her ro
ofs
genera
lly
require l
arg
er
dia
mete
r tu
rbin
es,
whilst
low
er
roofs
require s
maller
turb
ines
to a
llow
eve
n v
entila
tion o
ver
the e
ntire
roofe
d a
rea. Colo
ure
d t
iles
on t
he r
oofs
of hom
es
are
usu
ally
best
suited t
o t
he S
upaVent
range w
hic
h a
re a
vailable
in
a v
ariety
of co
lours
to m
atc
h the roof. A
range o
f m
ate
rials
is
als
o a
vailable
fro
m U
V s
tabilis
ed p
last
ic to m
eta
l tu
rbin
es.
Lightw
eig
ht
alu
min
ium
turb
ines
offer
a p
erform
ance
and c
orrosi
on a
dva
nta
ge o
ver
heavi
er
galv
anis
ed m
eta
l tu
rbin
es.
Turb
ove
nt has
train
ed d
eale
rs w
ho a
re a
ble
to a
ssis
t in
sele
ctin
g a
nd s
izin
g the rig
ht tu
rbin
e for yo
u.
How
turb
ines
are
inst
alle
d
Turb
ines
are
inst
alled o
n t
he roof; c
are
must
be t
aken t
o w
ate
rpro
of th
e inst
allation p
roperly. Inst
allations
should
only
be
carrie
d o
ut by
train
ed inst
allers
who w
ill lo
cate
, sp
ace
and s
eal tu
rbin
es
correct
ly.
Unit Siz
e (m
m) M
ater
ial E
xtra
ctio
n r
ate
Hei
ght (m
m) W
idth
(m
m) L
ength
(m
m) Pac
ked w
eight (k
g)
300
350
300
500
610
500
600
250
150
130
900
Alu
min
ium
Alu
min
ium
Galv
anis
ed
Galv
anis
ed
Alu
min
ium
Galv
anis
ed
Alu
min
ium
Alu
min
ium
Alu
min
ium
Poly
carb
onate
Poly
carb
onate
Poly
carb
onate
Alu
min
ium
Whirly
bird
GT-
12
Twis
ter
LP V
ent
SupaV
ent
Sew
erVen
t
GP V
ent
Hurr
ican
e
924m
3/h
r
1155m
3/h
r
924m
3/h
r
4695m
3/h
r
4695m
3/h
r
615
0m
3/h
r
615
0m
3/h
r
3770m
3/h
r
5395m
3/h
r
1229m
3/h
r
488m
3/h
r
68m
3/h
r
10000 -
12000m
3/h
r
460
545
460
620
620
620
620
535
620
510
240
110
936
475
490
475
730
730
800
800
630
755
345
240
210
1110
525
575
525
730
730
800
800
630
755
345
240
210
1130
2.7
3 6 21.
5
16.5
19.5
17 6.4
8.8
2.6
1.1
0.6
24.1
Turb
ine
ventila
tion s
pec
ifi c
atio
ns
Applica
tions
Turb
ove
nt in
troduce
d the fi rst
turb
ine v
entila
tors
into
the S
outh
Afric
an m
ark
et in
the late
1980s.
Sin
ce then, Tu
rbove
nt has
est
ablish
ed
itse
lf a
s th
e leader in
turb
ine v
entila
tion, offering the w
idest
range o
f tu
rbin
e v
entila
tors
to fi t a
ny
natu
ral ve
ntila
tion a
pplica
tion.
SupaV
ent on a
hom
e
SupaVents
are
ideally
suited t
o t
ile r
oofs
. They
matc
h t
he r
oof co
lour
exa
ctly
and a
re
easy
to inst
all b
y re
movi
ng o
nly
one tile.
Cle
ar S
upaV
ent al
low
ing lig
ht in
to a
n a
ttic
UV s
tabalise
d C
lear SupaVents
allow
natu
ral light th
rough the roof or attic
.
Whirly
birds
on a
fac
tory
Whirly
birds
are
ideally
suited t
o l
ow
roof-heig
ht
fact
ories
and b
uildin
gs
to a
llow
for
eve
n v
entila
tion.
Twis
ters
on a
war
ehouse
The larg
e a
nd r
obust
Tw
iste
r ra
nge a
llow
s fo
r best
ext
ract
ion r
ate
s fo
r ro
ofs
ove
r fo
ur
metres
hig
h.
Hurr
ican
e on a
fac
tory
Hurric
ane roof units
offer th
e u
ltim
ate
in q
uality
, w
ith the a
dded a
dva
nta
ge o
f ext
ract
ing
smoke in the e
vent of a fi re.
Without tu
rbin
es,
fact
ories
beco
me
pollu
ted w
ith h
ot, s
tale
air.
With turb
ines,
healthy
fresh
air is
pulle
d in fro
m o
uts
ide.
win
ter
sum
mer
Without ve
ntila
tion, m
oistu
re laden a
ir
rise
s and c
ondense
s in
roof sp
ace
s.W
ithout ve
ntila
tion, heat trapped in
the roof sp
ace
radia
tes
into
the h
om
e.
• Const
ruct
ed e
ntire
ly o
f hig
h q
uality
alu
min
ium
, m
akin
g it lightw
eig
ht, b
ut st
urd
y and rust
-
resi
stant.
• The b
all b
earings
use
d a
re s
uperior to
the b
ush
-typ
e b
earings
use
d in m
any
oth
er ve
ntila
tors
.
• The a
ero
foil v
anes
inco
rpora
te rolled e
dges
to p
revent
rain
and d
ust
fro
m p
enetr
ating t
he
dom
e.
• Ava
ilable
in tw
o s
izes:
either 300 m
m o
r 350 m
m (only
ava
ilable
in a
lum
iniu
m) dia
mete
r th
roat.
• Has
a s
tandard
mill
ed a
lum
iniu
m fi n
ish, w
hic
h c
an b
e c
olo
ur-co
ate
d o
n request
.
• The b
earings
are
perm
anently
seale
d, m
akin
g the W
hirly
bird e
ntire
ly m
ain
tenance
-fre
e.
• Th
e W
hirlybird
is
bac
ked b
y a
fi ve
-yea
r war
ranty. GT-12
has
a o
ne-
year
war
ranty.
• Ava
ilable
in e
ither hig
h q
uality
, light-w
eig
ht alu
min
ium
or ru
gged g
alv
anis
ed m
ild s
teel; these
can b
e c
olo
ur-co
ate
d o
n request
.
• Ava
ilable
with a
510
mm
or 610
mm
dia
mete
r th
roat.
• Has
two h
igh q
ualit
y se
ale
d b
earings
for trouble
-fre
e p
erform
ance
.
• Has
36 u
niq
uely
shaped v
anes
for enhance
d e
ffect
iveness
.
• Back
ed b
y a fi v
e-y
ear w
arranty
again
st d
efe
ctiv
e m
ate
rials
and m
anufa
cture
.
• The
turb
ine is
mad
e of a
light w
eight alu
min
ium
allo
y th
at h
as
a fl u
oro
carb
on p
rote
ctiv
e c
oating,
whic
h is
rust
and c
orrosi
on p
roof.
• It is
both
wate
rpro
of and d
ust
repelle
nt.
• Available
in t
wo s
izes
− e
ither
a 5
00 m
m a
nd 6
00 m
m d
iam
ete
r th
roat
– a
nd in a
gre
y
meta
l co
lour.
• Back
ed b
y a thre
e-y
ear w
arranty
.
• Const
ruct
ed fro
m li
ght wei
ght, corrosion res
ista
nt al
um
iniu
m, y
et it
has
bee
n tes
ted in
195 k
m/h
win
ds.
• The d
ouble
-row, heavy
-duty
ball b
earing s
yste
m e
nsu
res
optim
um
, trouble
-fre
e p
erform
ance
,
under a w
ide range o
f co
nditio
ns.
• The s
tandard
alu
min
ium
fi n
ish c
an b
e c
olo
ur-co
ate
d o
n request
– a
nd c
om
es
with m
atc
hin
g
acc
ess
ories.
• M
eets
inte
rnational st
andard
s as
a fi re s
moke e
xtra
ctor.
• Back
ed b
y a fi v
e-y
ear w
arranty
again
st d
efe
ctiv
e m
ate
rials
and m
anufa
cture
.
Our
top s
ellin
g tu
rbin
e fo
r hom
es a
nd fa
cto
ries
wit
h low
roofs
A h
igh q
uality
turb
ine: d
esig
ned a
nd m
anufa
ctu
red
in S
outh
Afr
ica f
or
facto
ries a
nd w
are
houses
A low
cost
an
d e
con
om
ical tu
rbin
e
Th
e u
ltim
ate
in
qu
ality
, as a
venti
lato
r
an
d s
moke v
enti
lato
r
for d
etail
ed s
pecs, siz
ing c
alculatio
ns a
nd c
ase s
tudie
s, please v
isit
ww
w.t
urbovent.c
o.z
a
Wh
irly
bir
d
Tw
iste
r
LP
Vent
Hurr
icane 9
00
• Ventila
tes
sew
era
ge s
yste
ms,
pits
and d
rain
s, rem
ovi
ng o
dours
and v
apours
.
• The turb
ine is
manufa
cture
d fro
m s
trong A
BS p
oly
mer alloy
whic
h is
inert to m
ost
aci
ds,
and c
an b
e u
sed in a
ny
envi
ronm
ent w
hic
h is
conta
min
ate
d b
y pollu
tants
and c
hem
icals
.
• M
ade fro
m a
speci
al poly
carb
onate
com
posi
tion that w
on’
t ru
st o
r co
rrode.
• Fi
ts o
n m
ost
sew
er pip
es-
the p
ipe a
dapte
r is
110
mm
or 15
0 m
m.
• Has
a 1
50 m
m d
iam
ete
r th
roat.
• Is
rela
tive
ly e
asy
to inst
all
and the v
ent sp
ins
sile
ntly.
• Back
ed b
y a fi v
e-y
ear w
arranty
again
st d
efe
ctiv
e m
ate
rials
and m
anufa
cture
.
• M
ade fro
m e
xceptionally
stro
ng, UV-resi
stant, A
BS p
oly
mer
whic
h c
an w
ithst
and h
ars
h
sun w
ithout
any
dete
riora
tion o
r co
lour
fadin
g. Unlik
e w
ith s
teel ve
nts
, ru
st w
ill n
eve
r be
a p
roble
m.
• Can w
ithst
and w
inds
of up to 1
80 k
m/h
.
• Is
ava
ilable
in a
ran
ge
of co
lours
to c
om
ple
men
t yo
ur ro
of, includin
g a
tra
nsp
arent ve
rsio
n.
• Has
a 2
50 m
m thro
at dia
mete
r.
• Back
ed b
y a fi v
e-y
ear w
arranty
cove
ring d
efe
ctiv
e m
ate
rials
and m
anufa
cture
.
• Pre
vents
back
dra
ftin
g a
nd c
him
ney
smoke b
ein
g b
low
n into
the h
ouse
and fro
m n
earb
y
build
ings,
tre
es a
nd n
atura
l to
pogra
phy
− by
causing a
positive
updra
ft in the
fl ue
or ch
imney
.
• Has
a thro
at dia
mete
r of either 15
0 m
m o
r 300 m
m.
• The s
tandard
colo
ur is
mill
alu
min
ium
, although p
ow
der co
at co
lours
can b
e a
rranged for
speci
al ord
ers
.
• Back
ed b
y a fi v
e-y
ear w
arranty
.
• Gets
rid
of st
ale
inte
rior air (in
cludin
g h
eat and o
dours
) w
hen the v
ehic
le is
in m
otion a
nd
the w
indow
s are
clo
sed.
• M
ade fro
m im
pact
resi
stant
poly
mer
and is
easy
to inst
all o
n a
wid
e r
ange o
f vehic
les,
incl
udin
g c
ars
, va
ns,
boats
and tru
cks.
• Ensu
res
an a
dequate
supply
of oxy
gen, th
ere
by
incr
easi
ng d
rive
r ale
rtness
and reduci
ng the
poss
ibili
ty o
f ro
ad a
ccid
ents
.
• Back
ed b
y a thre
e-y
ear w
arranty
again
st d
efe
ctiv
e m
ate
rials
and m
anufa
cture
.
A p
rem
ium
hom
e r
oof
vent
desig
ned f
or
easy
DIY
insta
llati
on
A v
ent
made s
pecifi c
ally f
or
chim
neys a
nd fl u
es
A v
ent
specifi c
ally d
esig
ned f
or
vehic
les
A v
ent
made s
pecifi c
ally for
conta
min
ate
d a
reas
for d
etail
ed s
pecs, siz
ing c
alculatio
ns a
nd c
ase s
tudie
s, please v
isit
ww
w.t
urbovent.c
o.z
a
Su
paV
ent
Su
re D
raft
GP
Vent
Sew
erV
ent
TURBINE VENTILATORS • EVAPORATIVE COOLERS • AIR CONDITIONERS • FIREPLACES • PARTS & ACCESSORIES
Turbovent dealers offer a turnkey service which includes on-site assessment, system specifi cation, installation, system support and servic-
ing on all turbine ventilators.
Established in 1990, Turbovent has continued to offer innovative products and an uncompromising approach to service. This is matched
with an equally good reputation.
Besides turbine ventilators, Turbovent has an extensive product range that provides superior solutions for indoor air quality. This includes
air conditioners, evaporative coolers, portable cooling and combustion fi replaces.
*Turbovent offers training, after-sales service and technical support to a network of dealers throughout Southern Africa.
t: +27 11 613 6921 • f: +27 11 613 1241 • 412 Heidelberg Road, Tulisa Park 2197 • www.turbovent.co.za