tunnel lighting 5

2
Tunnel lighting LED guidance beacon Thanks to its 12 LEDs on either side, the BJ guidance beacon acts as a visual guide both in normal conditions and when there is smoke due to a fire. A direct 230 V power supply is also possible – in which case a transformer is inte- grated. The Mont Blanc tunnel is equipped with the BJ guidance beacon. The emergency lighting in the tunnel was completely revamped following the deadly fire in 1999. APPLICATIONS In normal conditions: visual guidance for motorists. In case of fire: efficient guidance for motorists or pedestrians and emergency services, even through smoke. ADVANTAGES No maintenance whatsoever Very long-lasting diodes (LEDs) High tightness level (IP 67) during the whole lifetime of the guidance beacon Very high level of protection against corrosion due to a spe- cific treatment, identical to the one applied to luminaires Resistance to impacts and vibrations Compact Non-electrostatic material Washable with a high pressure jet with no risk of deterioration DESCRIPTION The beacon in die cast aluminium includes two sealed win- dows in polycarbonate or tempered glass, as well as two cir- cuits each including 12 amber, blue or green LEDs. The beacon is mounted with stainless steel screws. Electricity is supplied either by a cable and socket, or by a compression gland, or by connectors on the back of the bea- con. Optional: in the case of a 230V direct power supply, the device is provided with a box containing the transformer. In this case, the two screws used to mount the beacon allow access to the box. Electricity is supplied via a compression gland. A second compression gland can be installed permitting a looped feed. BJ Tightness level (*) IP 67 Impact resistance (protector) (**) IK 10 (polycarbonate) IK 08 (tempered glass) Electrical class (*) I (230V) III (24V) Fire behaviour (***) V0 0% halogen Weight 1 kg (*) according to standard EN 60598-1 / -2.3 (**) according to standard EN 50102 (***) according to standard UL 94 The BJ guidance beacon provides maximum intensity in a 4° angle of vision, which is optimal for both emergency services and motorists or pedestrians heading towards emergency exits.

Upload: dimaomar

Post on 12-Dec-2015

3 views

Category:

Documents


0 download

DESCRIPTION

tunnel lighting

TRANSCRIPT

Page 1: tunnel lighting 5

Tunnel lightingLED guidance beacon

Thanks to its 12 LEDs on either side, the BJ guidance beacon acts as a visual guide both in normal conditions and when there is smoke due to a fire. A direct 230 V power supply is also possible – in which case a transformer is inte-grated.

The Mont Blanc tunnel is equipped with the BJ guidance beacon. The emergency lighting in the tunnel was completely revamped following the deadly fire in 1999.

APPLICATIONS

In normal conditions: visual guidance for motorists.

In case of fire: efficient guidance for motorists or pedestrians

and emergency services, even through smoke.

ADVANTAGES

• No maintenance whatsoever

• Very long-lasting diodes (LEDs)

• High tightness level (IP 67) during the whole lifetime of the

guidance beacon

• Very high level of protection against corrosion due to a spe-

cific treatment, identical to the one applied to luminaires

• Resistance to impacts and vibrations

• Compact

• Non-electrostatic material

• Washable with a high pressure jet with no risk of deterioration

DESCRIPTION

The beacon in die cast aluminium includes two sealed win-

dows in polycarbonate or tempered glass, as well as two cir-

cuits each including 12 amber, blue or green LEDs.

The beacon is mounted with stainless steel screws.

Electricity is supplied either by a cable and socket, or by a

compression gland, or by connectors on the back of the bea-

con.

Optional: in the case of a 230V direct power supply, the device

is provided with a box containing the transformer. In this case,

the two screws used to mount the beacon allow access to the

box. Electricity is supplied via a compression gland.

A second compression gland can be installed permitting a

looped feed.

BJ

Tightness level (*) IP 67

Impact resistance (protector) (**) IK 10 (polycarbonate)IK 08 (tempered glass)

Electrical class (*) I (230V) III (24V)

Fire behaviour (***) V0 0% halogen

Weight 1 kg

(*) according to standard EN 60598-1 / -2.3(**) according to standard EN 50102(***) according to standard UL 94

The BJ guidance beacon provides maximum intensity in a 4° angle of vision, which is optimal for both emergency services and motorists or pedestrians heading towards emergency exits.

Page 2: tunnel lighting 5

BJ

INSTALLATION

Very rapid assembly and disassembly: installation on a wall or

the ground using two M8 stainless steel screws.

Angle de vision

Inte

nsi

té (

cd)

Balise avec LED de couleur ambre

-10 002468

1012141618

-20-30 302010

OPTIONS

• Insulating base to be placed between the unit and its support

• Any RAL colour

• Choice of LED colours

• No box for direct 24V power supply

ELECTRICAL INSTALLATION

In the case of a direct 24V power supply:

- crossover cabling is possible by putting a second compression

gland or a connector behind the head of the device.

When a beacon is unplugged, it is possible to keep the line elec-

trically live by joining the two connectors.

In the case of a 230V power supply:

- the transformer is integrated into the box. A releasable plug is

used to connect the box and the beacon. The transformer can be

very easily accessed via the two screws situated at the front of

the unit.

Consumption: 2 W - 0.08 A

PHOTOMETRY

DIMENSIONS

Version with box (optional):

This table shows that the maximum intensity is reached in a 4°

angle of vision, which corresponds to the position of motorists

in normal traffic conditions, or of pedestrians who are heading

towards emergency exits.

82 m

m

188

mm

98 mm

188

mm

135

mm

98 mm33 mm

Sign beacon with amber-coloured LED

Angle of vision

Inte

nsi

ty (

cd)

www.schreder.com