Page 1: TUNABLE DIODE LASER GAS ANALYZERS H2S / CO2 / MOISTURE ... · Zero Baseline TDLAS technology uses non-absorbing adjacent wavelengths as a zero point. This is an easier analysis than

TUNABLE DIODE LASER GAS ANALYZERSH2S / CO2 / MOISTURE ANALYSIS

SERIES 6020L & 8800L

Page 2: TUNABLE DIODE LASER GAS ANALYZERS H2S / CO2 / MOISTURE ... · Zero Baseline TDLAS technology uses non-absorbing adjacent wavelengths as a zero point. This is an easier analysis than

[email protected]://www.teledyne-ai.com2

Our Advantage

Wavelength Modulation Spectroscopy(WMS)WMS is a method used to significantly increase the

sensitivity by reducing the low-frequency noise. The laser

light’s intensity is modulated at a high frequency to create a

periodic signal to the detector. The signal is then encoded

and measured at a high frequency, eliminating the effect of

low frequency noise.

Zero BaselineTDLAS technology uses non-absorbing adjacent

wavelengths as a zero point. This is an easier analysis than

detecting a small change in a large signal.

Permanent Wavelength TrackingThe absorption of wavelengths is measured in reference to

two other absorption points to compensate for common

frequency shift. This results in excellent long-term

repeatability to minimize analyzer verifications.

Not resorting to differential measurements means no

switching valves, less hassle disposing of scrubber media,

lower cost of ownership, uncertainty of the CO2, CH

4 and

C2H

4 interferences are zeroed and a much faster respon-

se/reading time.

Direct Measurements

Sample SystemThis has 316 stainless steel tubing and fittings with a

GenieTM filter along with flow control and precision

sample cell pressure regulation.sample cell pressure regulation.

Herriott Sample Cell

Multi-pass cell with an effective path length of ~33 feet

(~10 meters). The sample cell is heated and controlled at

± 50°C 1°C by a wrap around heater.

Output

Source

Product FeaturesFully certified for hazardous area

Precision temperature control of the sample cell

316 stainless steel sample system with GenieTM filter and pressure regulation

Display: IDEC 5.7-inch touchscreen

I/O: 1 x 4-20 mA, 2 x alarm contacts TIA-485/232, USB2, Ethernet (supports MODBUS)

Teledyne’s 6020L and 8800L series of analyzers leverage the latest in Tunable Diode Laser Spectroscopy (TDLAS) to achieve

ultra-low, fast and reliable analysis of hydrogen sulfide (H2S), carbon dioxide (CO

2) and moisture (H

2Ov). By tuning each laser

to a specific absorption wavelength, based on the gas of interest, the attenuation of the light through a sample cell and the

detector can be correlated to the concentration of each gas, per Beer-Lambert Law.

Page 3: TUNABLE DIODE LASER GAS ANALYZERS H2S / CO2 / MOISTURE ... · Zero Baseline TDLAS technology uses non-absorbing adjacent wavelengths as a zero point. This is an easier analysis than

[email protected]://www.teledyne-ai.com3

SPECIFICATIONSModel 6020L Model 6020L Model 8800L

Parameter

Typical Ranges

Certifications

Laser Specification

Repeatability

Linearity

T90 Response Time

Temperature

Ingress Protection

Inlet Pressure

Wetted Materials

Display

Outputs

Power

Dimensions

Inlet Flow

H2S CO

2 Moisture (H2Ov)

0-10 ppm to 0-20% 0-100 ppm to 0-100% 0-5 ppm to 0-2,500ppm

North America Version

CSA Class I Div 1 Groups B,C,D T4 (T3 with opt. freeze-proof heater)

CSA Class I Div 2 Groups B,C,D T4 (T3 with opt. freeze-proof heater)

International Version

ATEX Zone 2 IIB+H2 T4

Class 1

± 2% FS

± 1% FS

4 seconds

NEMA-4/7 explosion-proof

2-4 SCFH (1-2 SLPM)

Tubing/Fittings: 316 stainless steel

Sample Cell: Nickel-plated aluminum

IDEC 5.7-inch touchscreen

22 psig (1.5 bar G) nominal

Anolog Outputs: 1 x 4-20 mADC (isolated)

Discrete Outputs: 2 x alarm contacts, concentration and valid data

Communications: TIA-232 , TIA-485, RJ-45 Ethernet (supports MODBUS)

100-240 VAC 47-63 Hz, 100W

(Optional) 24VDC, 100W

Approximately 25” W x 52” H x 12” D

(635 x 1,320 x 305 mm)

+4 to +140°F (-20 to + 60°C) for most applications

Page 4: TUNABLE DIODE LASER GAS ANALYZERS H2S / CO2 / MOISTURE ... · Zero Baseline TDLAS technology uses non-absorbing adjacent wavelengths as a zero point. This is an easier analysis than

Rev-A 1/17/2019

[email protected] w w.teledyne-ai .com

[email protected] w w.teledyne-ml.com

Middle East OfficeSharjah

UNITED ARAB EMIRATES (UAE)TEL: +971.6557.9727

California OfficeCity of industry, CA

United states of america (USA)TEL: +1 626.934.1500

Southeast Asia Officepetaling jaya

MALAYSIATEL: +603.7805.7712

colorado officeEnglewood, co

United states of america (USA)TEL: +1 303.792.3300