tsi md akh al sinan presentation 2014-12-04

15
1 Presentation on Texas Sampling MD Flow Thru System Abdul Karim H. Al-Sinan & Partner For Trading Co. (Trading & Contracting), KYTOS ARABIA P.O. Box 374, Makkah Street, Jubail 31951,KSA Tel: (966) 13 362 3939; Fax :(966) 13 362 4886 Email: [email protected]

Upload: afroznishat

Post on 17-Sep-2015

222 views

Category:

Documents


6 download

DESCRIPTION

Presentation

TRANSCRIPT

Texas Sampling Incorporated

1Presentation on Texas SamplingMD Flow Thru System

Abdul Karim H. Al-Sinan & Partner For Trading Co. (Trading & Contracting), KYTOS ARABIAP.O. Box 374, Makkah Street, Jubail 31951,KSA Tel: (966) 13 362 3939; Fax :(966) 13 362 4886

Email: [email protected]

12Manual ContinuousSampling liquid into a Bottle or Container

3

MD: Sample Mode4

MD: Patented Purge Mode5MD versus 3-way ball valveMD has hardened ceramic seat (8x stronger than steel versus 3-way soft seatMD has (or larger) flow through porting versus for 3-wayMD is proprietary sample valve technology versus 3-way ball valve technologyMD has TSI bolt pattern for easy addition of secondary ISO valve or change to stinger tubeMD has a multi-turn handle to allow control of flow into bottle versus 3-way quarter turn handleMD has no internal volume allowing for a representative sample versus 3-way with ball valve cavity.TSI can supply either the MD or the 3-way versus customer preference but the MD is a durable robust valve designed for process sampling 6

Hardened SeatOptional PurgeFlow ThroughEasy Bolt Pattern for various orientationsReplaceable Needles7Vent Needle: Pencil PointPencil Point Design: reduces plugging of vent needle

8

Patented PNP Rotameter indicates positive flow

Optional Carbon CanisterProcedure TagStainless Steel Bottle ShroudDrawing A19

10Ssisisisisisisisis

MD Layout Additional Features : A1This drawing features the patented MD flow thru valve discussed above as well as the pencil point vent needleThis system is equipped with a bottle enclosure to further protect the operatorProcess block valves are equipped on the inlet and outlet of the sample systemAn optional cooler is shown for cooling the process prior to sampling.11Drawing E212

13

MD with Stinger and EnclosureSteam Stinger

Drawing E2 is equipped with a steam stinger so that the process is kept hot throughout the sampling process. The steam stinger will insure that the sample will not set up in the line in order to achieve a representative sample each time.This system is also equipped with a bottle enclosure to protect the operator from any exposure to the sample.

14Thank you to