ts-3gbts-sw-0120 feature ran1849 bts licensing - logical target id for flexi bts

7
© Nokia Siemens Networks Company Confidential 1 (7) Technical Support Note TS-3GBTS-SW-0120 Feature RAN1849: BTS Licensing - Logical Target ID for Flexi BTS Radio Access Systems 3GBTS WN6.0 This document contains following type of information Informative x Preventive Corrective Urgent Security Information is classified as Internal Public x Customer Specific

Upload: andres-f-hernandez-senegal

Post on 16-Nov-2015

18 views

Category:

Documents


5 download

DESCRIPTION

TS-3GBTS-SW-0120 Feature RAN1849 BTS Licensing - Logical Target ID for Flexi BTSBTS LICENSING

TRANSCRIPT

  • Nokia Siemens Networks Company Confidential 1 (7)

    Technical Support Note TS-3GBTS-SW-0120

    Feature RAN1849: BTS Licensing - Logical Target ID for Flexi BTS

    Radio Access Systems

    3GBTS

    WN6.0

    This document contains following type of information

    Informative x Preventive Corrective Urgent Security

    Information is classified as Internal Public x Customer Specific

  • Nokia Siemens Networks Company Confidential 2 (7)

    Table of Contents 1. Validity............................................................................................................................................3 2. Compatibility / Dependencies to other products.............................................................................3 3. Keywords........................................................................................................................................3 4. Summary ........................................................................................................................................3 5. Detailed description........................................................................................................................3 6. Potential issue ................................................................................................................................5 7. WORKAROUND.............................................................................................................................5 7. Note................................................................................................................................................6 8. References .....................................................................................................................................6

    Contact:

    [email protected]

    Summary of changes:

    08.06.2010 1.0 Draft First draft version/Juha Mourujarvi 09.06.2010 1.0 First approved version / Pekka Tormanen 17.06.2010 2.0 Updated version / Juha Mourujarvi

    Comparability between RAN1849 features corrected.

    18.06.2010 2.0 Updated version approved / Pekka Tormanen 15.07.2010 3.0 Updated version / Juha Mourujarvi 24 hours

    waiting time added before new module installation. 16.07.2010 3.0 Updated version 20.09.2010 4.0 Draft Updated version / Juha Mourujarvi Chapter 5

    corrected 21.09.2010 4.0 Updated version approved / Pekka Tormanen 17.12.2010 5.0 Draft Updated version/Juha Mourujarvi, Chapter 6

    added. 15.02.2011 5.0 Updated version approved / Pekka Tormanen 24.02.2011 6.0 Attachment changed no need for password

    mailto:[email protected]

  • Nokia Siemens Networks Company Confidential 3 (7)

    Purpose

    The purpose of this document is to provide information about RAN1849 feature related to BTS Licensing with Logical Target Id for Flexi WCDMA BTS.

    1. VALIDITY

    2. COMPATIBILITY / DEPENDENCIES TO OTHER PRODUCTS

    RNC, OSS, NetAct

    3. KEYWORDS

    RU20, RN5.0, WN6.0, RAN1849, Logical Target Id, NTP time synchronisation, FSM (Flexi System Module), FR (Flexi RF Module).

    4. SUMMARY

    In this Technical Support Note information about RAN1849 feature: usage of Logical Target Id in BTS Licensing is provided. This feature does not require any new or additional HW. Simplified and harmonized license management will reduce OPEX.

    5. DETAILED DESCRIPTION

    The current licensing concept uses the HW serial number of the System Module as the Target Id for Flexi BTS license keys. With that feature the Target Id is no longer HW related and remains valid during the whole lifecycle of the Flexi BTS also in a case of FSM or RF Module swap. So HW Related Target Id will become Logical Target Id meaning that License Management will be automatic.

    Product W

    CC

    A, S

    upre

    me

    Indo

    or,

    4681

    89A

    WIN

    A, S

    upre

    me,

    469

    378A

    WIN

    B, S

    upre

    me

    Indo

    or,

    4698

    83A

    WO

    DA

    , Sup

    rem

    e O

    utdo

    or

    4693

    79A

    WC

    CC

    , Opt

    ima

    Indo

    or,

    4687

    58A

    WB

    BA

    , Opt

    ima

    Com

    pact

    IB

    BU, 4

    6822

    0A

    WR

    EA

    . Opt

    ima

    Com

    pact

    RF

    ext.,

    469

    221A

    WR

    EB, O

    ptim

    a C

    ompa

    ct,

    4697

    72A

    WC

    CM

    , Met

    ro S

    ite 4

    6871

    4A

    WC

    CF,

    Met

    ro S

    ite 5

    0

    4703

    25A

    WTC

    A, T

    riple

    -mod

    e 46

    8888

    A

    Flex

    i W

    CD

    MA

    BTS

    WCDMA BTS

    X

  • Nokia Siemens Networks Company Confidential 4 (7)

    This introduces the following advantages to operators: Improved operability of the License Management and

    HW replacements of the FSMx does not require the substitution of license files anymore. The license files are automatically aligned between License Manager and Flexi BTS.

    The substitution process after the System Module swap is obsolete. Step towards the autonomous License Management running completely in the

    background.

    Pre-conditions

    BTS reset must be triggered before the HW module is being replaced. The

    reset causes an immediate update of the timestamp stored at FSM and RF Module.

    Both FSM and RF Modules must not be replaced at the same time

    The unique Logical Target Id is generated in the NodeB consisting of the FSMs serial number and timestamp information _ (e.g. L6100232744_120551). In case of RU10 and RU20 upgrade the former FSM serial number will be used without timestamp information. As the logical Target Id at Flexi BTS must be unique in whole network, NetAct connection is needed to verify its uniqueness each time FSM swap is done. Whenever a Target Id is generated, a copy of that Target Id is stored simultaneously to Master FSM and all RF Modules. In order to avoid duplicate Target Id problem mentioned in Note chapter below follow these instructions:

    To ensure the usage of the correct ID, e.g. when taking a module from another

    BTS - a timestamp (last time used) is stored in the module and updated once a day. Consequently a module must be out of operation at least 24 hours before it can be used in another BTS or alternatively a reset has to be triggered.

    The BTS in question should be reset in order to force an immediate update of

    the timestamp. In this way the FSM and RF Modules have their newest timestamp before one of the modules is replaced.

    In order to ensure the accurate timestamp the BTS has to be synchronized

    with the NTP (Network Time Protocol) time.

    The backward compatibility enables to use the already available Target Id and installed license files.

    An upgrade to RU20 does not have any effect on the license-controlled

    features being activated in previous releases as in RU20 there is in place an automatic conversion from HW Target Id to logical Target Id.

  • Nokia Siemens Networks Company Confidential 5 (7)

    6. POTENTIAL ISSUE

    When swapping two FSM at the same time the following scenario may happen in BTS startup:

    In the original site Timestamp value read from sites FR(s) is newer than the one stored in the replacing FSM. This causes that Target Id value stored into the FR(s) is copied from there to the replacing FSM.

    In the new site Timestamp value read from the reused FSM is newer that the one(s) stored in sites FR(s). This causes that Target Id value stored into the reused FSM is copied from there to sites FR(s).

    NOTE, that no Timestamp value (completely new module) means older Timestamp value than any existing Timestamp value. When these two things happen it means that same Target Id value is about to be used in two different BTSs. To prevent this from happening, if any copying of Target ID value is done at BTS startup (from FSM to FR(s) or vice versa), NMS is always requested to verify the Target Id value which BTS is about to take into use. When two BTSs request verification for the same Target Id value, NMS needs to reject one of those requests. This way NMS prevents two different BTSs using the same Target Id value. This rejection then causes that BTS which received it, will clear stored Target Id and Timestamp values from all of its modules, resets itself and then in next startup generate a new Target Id value for itself (because nothing is stored into modules) and again request verification of (the generated) Target Id value from NMS. Before correction is available the workaround detailed in chapter 7 should be used if site is not coming On Air. When this workaround is used a NEW set of licenses are necessary to be loaded. All the existing ones will be lost.

    7. WORKAROUND

    Instructions for TargetIdCleanup usage: Pre-setup:

    FSMC/D/E is moved to new site PC is locally connected to FSMC/D/E with FTM unit RF MODULES NEEDS TO BE DISCONNECTED (TO AVOID TARGET ID

    REPLICATION TO RF MODULE) Microsoft .NET Framework version 2.0 is installed to PC (Can be found from

    microsoft.com)

    Cleanup process: Open Site Manager. Enable BTS Telnet and FTP access (Tools->Enable

    BTS Telnet and FTP access) Execute TargetIdCleanup.exe

    o Deletes licenses from FCM o Erases Target ID from FCM

    Reset BTS via Site Manager Check from site manager license management view that new target ID is

    generated (this may take up to 10 minutes from reset) Connect RF modules and continue site construction If WBTS Alarm Failure in license activation is displayed, please reset site to

    clear. This may generate a new logical target ID for the site Once BTS has new target ID, all licenses can be downloaded to the site via

    Netact License Manager or using local license files.

  • Nokia Siemens Networks Company Confidential 6 (7)

    Package

    7. NOTE

    ---

    8. REFERENCES

    More information will be available in the next publishing release document: WCDMA RAN, rel. RU20, Feature Descriptions

  • Nokia Siemens Networks Company Confidential 7 (7)

    Disclaimer

    The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

    The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given as is and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA, THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2011. All rights reserved.

    1. VALIDITY 2. COMPATIBILITY / DEPENDENCIES TO OTHER PRODUCTS3. KEYWORDS4. SUMMARY5. DETAILED DESCRIPTION6. POTENTIAL ISSUE7. WORKAROUND7. NOTE8. REFERENCES