târlea gratiela eugen vargolici sustainable development
TRANSCRIPT
![Page 1: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/1.jpg)
12:11 PM
SLIDE 1
Târlea Gratiela
Eugen Vargolici
SUSTAINABLE DEVELOPMENT
ECOLOGICAL REFRIGERATION
AND AIR CONDITIONING STUDY
CASES
Prof.dr.ing.Târlea Gratiela- Maria - AGFR Vicepresident,
Ing.Eugen Vargolici S.C.Termotest S.R.L .- PFACR Vicepresident
Romanian General Association of Refrigeration
Pache Protopopescu, no.66 Bucharest
![Page 2: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/2.jpg)
INTRODUCTION
• Study of the Romanian line up to the
environment, refrigeration and air-
conditioning EU legislation with the
recommendation of using ecological
refrigeration systems.
• Some refrigeration, gas heat pump and air
conditioning new study cases are
presented.
![Page 3: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/3.jpg)
INTRODUCTION
• Romania signed Kyoto (1997) and Montreal Protocol (1987) and in the same time as a new member of the EU, it has obligations to respect the environmental legislation. CFC's have been replaced in many applications with HFC's (hydro fluorocarbons) and HCFC's (hydro chlorofluorocarbons).
![Page 4: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/4.jpg)
INTRODUCTION
• On an international level, the role of non-vapor compression methods such as absorption (Study case 2), adsorption etc. may have become more important; however, vapor compression cycles are thought to remain the most important candidates.
• For the long term, only five important different refrigerants remain options for the vapor compression cycle in all refrigeration and A/C sectors : ammonia (R-717), carbon dioxide (R-744); hydrocarbons and blends (HCs, HC-290, HC-600a, HC-1270), hydrofluorocarbons (HFCs, unsaturated HFCs (HFOs)) and water (R-718).
![Page 5: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/5.jpg)
ROMANIA, AMMONIA TRADITIONAL USER Some examples of such objectives are:
• GALIGALO Brasov, TRANSAVIA, AGRONUTRISCO Mihailesti, TUBORG Bucuresti, WAREHOUSE Tulcea, SCANDIA Sibiu, EUROPEAN DRINKS, URSUS Timisoara, URSUS Cluj, MILENIUM Bucuresti, CEFIN Bucuresti, PARMAFOOD Bucuresti; AVICOLA Buzau; Onesti SLAUGHTERHOUSE; BEER FACTORY INTERBREW Ploiesti, LOGISTIC PARK DELHAIZE and many others;
• For industrial refrigeration systems, these objectives were built, mostly, with European support.
![Page 6: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/6.jpg)
COP VALUES FOR R717 AND R404A
Slaughterhouse- Study Case 1
R717 R404A
-40/-10 ˚C -10/ +35˚ C -40/+35 ˚C -10/+35 ˚C 0/+45 ˚C
COP 4.10 3.84 1.24 2.78 2.79
![Page 7: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/7.jpg)
AMMONIA POULTRY
SLAUGHTERHOUSES
![Page 8: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/8.jpg)
AMMONIA AS A VERY ECO-EFFICIENT
REFRIGERANT ALTERNATIVE
• Ammonia like R404A has advantages and disadvantages which should be take into consideration by the equipments producers.
• Ammonia and hydrocarbons are more often used in industrial and domestic refrigeration systems, but their toxicity, flammability and security are limited to be used in refrigeration plants.
• As it was shown in the paper, ammonia is the best ecological refrigerant alternative (has ODP = 0 and GWP = 0).
![Page 9: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/9.jpg)
ROMANIA, AMMONIA TRADITIONAL USER
• Making analyses on the Romanian market during the last five years, it can be concluded that the most important application where ammonia was used, was in the food industry.
• First carbon dioxide (R-744) refrigeration system!
• Were rebuilt or built many refrigeration systems for warehouses, beer factories, poultry slaughterhouses, soft drinks factories, logistic parks, diary factories, wines factories, ice rings and so on. Each industrial refrigeration plant was made in one/two compression stages, with classical equipments.
• Next figures show the most important types of compressors, condensers, evaporators, used in Romanian ammonia refrigeration plants and a general view of the ammonia industrial refrigeration sector, in the last years.
![Page 10: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/10.jpg)
COMPRESSORS, EVAPORATORS AND CONDENSERS USED
IN ROMANIAN AMMONIA REFRIGERATION PLANTS IN THE
LAST FIVE YEARS
Evaporators
0%
10%
20%
30%
40%
50%
60%
Fin space 7 mm Fin space 10 mm Fin space 12 mm
Ammonia compressors
10%
20%
70%
0%
10%
20%
30%
40%
50%
60%
70%
80%
reciprocating 2 stage reciprocating 1 stage screw
Condensers
10%
90%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
With w ater Evaporative
![Page 11: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/11.jpg)
AMMONIA INDUSTRIAL REFRIGERATION IN
ROMANIAN IN THE LAST FIVE YEARS
Industrial Refrigeration
Warehouse; 60%
Slaugther house;
15%
Diary; 3%
Meat processing
factory; 5%
Vegetables; 5%
Chemicals; 2%Drinks; 10%
![Page 12: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/12.jpg)
CONCLUSIONS AND FUTURE WORK
• Romania, ammonia traditional user;
• The recommendation of using eco- efficient refrigeration systems.
• Romania is a country in transition and also EU-member starting with 2007;
• AGFR – PFACR - Cooperation Agreement and Working Group Established to solve problems (certification of the professional competence of companies and specialists working in refrigeration and air conditioning);
• POSDRU- 58665 - SECTORIAL PROJECT-FPC FRIGO ECO –Training courses;
• National and international level cooperation with similar organizations.
![Page 13: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/13.jpg)
Thank you for your
attention!
Activities for the Clearing House: develop the
web page (www.agfro.ro) for the dialogue with
the trade and other interested stakeholders
http://www.agfro.ro
![Page 14: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/14.jpg)
Absorption Chiller - Study Case 2
![Page 15: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/15.jpg)
![Page 16: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/16.jpg)
![Page 17: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/17.jpg)
![Page 18: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/18.jpg)
![Page 19: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/19.jpg)
![Page 20: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/20.jpg)
11
(month)
4 5 6 7 8 9 10 12 1 2 3
60
70
80
90
100
(%)
Electricity
Gas
JAPANESE MARKET
Energy saving was a need in 1973 in Japan after the oil shock. The
electricity demand for A/C was rising too fast. After the GHP was
introduced to the Japanese market the electricity demand did not change.
Peaks were satisfied by increasing the use of gas.
Gas Heat Pump (GHP) Study Case 3
![Page 21: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/21.jpg)
![Page 22: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/22.jpg)
GAS
ENGINE
Gas
100%
Torque
32%
53%
Heat
recovery
15%
Loss
Available for
compressors
Available for
refrigerant cycle
and domestic hot
water
Friction and not
recovered heat
Engine coolant and
exhaust gas
![Page 23: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/23.jpg)
Central
Remote Control
Unified On/Off
Control
Weekly Timer
Intelligent
Touch Controller
![Page 24: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/24.jpg)
Brazed connections
16 – 20 – 25 HP
Outline drawing
![Page 25: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/25.jpg)
Boiler + Chiller
FANCOIL FANCOIL FANCOIL FANCOIL
PUMP
ST
OR
AG
E
FANCOIL FANCOIL FANCOIL FANCOIL
PUMP
ST
OR
AG
E
GHP AISIN + AWS YOSHI
![Page 26: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/26.jpg)
Cooling mode
Heating mode
16 – 20 – 25 HP
![Page 27: Târlea Gratiela Eugen Vargolici SUSTAINABLE DEVELOPMENT](https://reader030.vdocuments.mx/reader030/viewer/2022021405/62088d3f6f29e406227c2329/html5/thumbnails/27.jpg)
Thank you for your
attention!
http://www.agfro.ro