tritium detection methods and limitations...tritium detection methods and limitations tritium focus...
TRANSCRIPT
![Page 1: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/1.jpg)
Tritium Detection Methods and Limitations
Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico
![Page 2: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/2.jpg)
DOE-HDBK-1105-2002
RADIOLOGICAL TRAINING FOR TRITIUM FACILITIES
U.S. Department of Energy AREA TRNG Washington, D.C. 20585
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
![Page 3: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/3.jpg)
DOE-HDBK-1105-2002 Radiological Training for Tritium Facilities
U.S. Department of Energy, Radiological Control Programs for Special Tritium Compounds, DOE-STD- draft, Washington, D.C. (2001). U.S. Department of Energy, Acceptable Approach for Developing air Concentration Values for Controlling Exposures to Tritiated Particulate Aerosols and Organically-Bound tritium, Radiological Control Technical Position 2001-02, Washington, D.C. (2001). Voss (2000), J. T., LA-UR-00-2584, Los Alamos Radiation Monitoring Notebook, (2000). Woehr (1994), W.J., Gatami, A. and Holodny, E. I., Radioactive Waste Volume Reduction in a University/Hospital Setting, 27th Mid-Year Topical Meeting of the Health Physics Society, February 12-16, Albany, NY (1994).
![Page 4: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/4.jpg)
ION CHAMBER DETECTORS
• PORTABLE ION CHAMBERS • AREA (ROOM) ION CHAMBERS • EFFLUENT (STACK) ION CHAMBERS
![Page 5: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/5.jpg)
PORTABLE ION CHAMBERS
200 to 400 cc active volume 5 to 10 uCi/m3 lower limit 10,000 to 200,000 uCi/m3 upper limit
![Page 6: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/6.jpg)
AREA (ROOM) ION CHAMBERS
2000 cc active volume 1uCi/m3 lower limit 1 to 20 uCi/m3 upper limit
![Page 7: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/7.jpg)
EFFLUENT (STACK) ION CHAMBERS
50 L active volume 5 uCi/m3 lower limit 1 to 50 Ci/m3 upper limit
![Page 8: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/8.jpg)
10CFR835 tritium DAC factors
Tritium Oxide 2E-5 uCi/mL (20 uCi/m3) Elemental 2E-1 uCi/mL Insoluble STCs 2E-6 uCi/mL Soluble STCs 1E-5 uCi/mL
![Page 9: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/9.jpg)
LIQUID SCINTILLATION COUNTERS
• PORTABLE LSC • LABORATORY LSC • PROCESS LSC
![Page 10: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/10.jpg)
Table 1 OF DOE 5400.5 &
Appendix D OF 10CFR835
Tritium surface limit 10,000 dpm/100cm2
![Page 11: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/11.jpg)
RETROSPECTIVE TRITIUM SAMPLERS
• BUBBLERS • HTO ABSORBERS
![Page 12: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/12.jpg)
P-10 GAS COUNTERS
• PORTABLE SURFACE MONITORS • LABORATORY SAMPLE COUNTERS • P-10 STANDARD TRITIUM CALIBRATORS
![Page 13: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/13.jpg)
TRITIUM CONCENTRATORS
• NAFION FIBER • SELECTIVE EVAPORATION
![Page 14: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/14.jpg)
LRAD – LONG RANGE ALPHA DETECTION
• HISTORY OF LRAD AND ITS DERIVATIVES • HOW THIS RELATES TO TRITIUM
![Page 15: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/15.jpg)
MEASUREMENT LIMITATIONS
• MINIMUM AND MAXIMUM RANGE OF DETECTION
• UNCERTAINTIES – NIST-TRACEABLE TRITIUM STANDARD – TRITIUM DECAY CALCULATIONS – TRITIUM PERMEATION THRU CONTAINMENT (AND
HYDROGEN INFILTRATION INTO CONTAINMENT) – CURRENT FLOW IN ION CHAMBERS – COUNTING EFFICIENCY
![Page 16: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/16.jpg)
MEASUREMENT LIMITATIONS – CONTINUED
• UNCERTAINTIES - CONTINUED – SAMPLE SELF-SHIELDING – SAMPLE VOLUME – TEMPERATURE AND BAROMENTRIC PRESSURE – GAMMA CORRECTION – LEAKAGE CURRENT IN ION CHAMBERS – DARK CURRENT IN PMTS
![Page 17: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/17.jpg)
INTERFERENCES
• EXTERNAL GAMMA FIELDS • RADON AND THORON • RADIOACTIVE GASES • RF AND EMF • AC AND BATTERY POWER FLUCTUATIONS • TEMPERATURE SHOCK • MECHANICAL SHOCK • GEOTROPISM
![Page 18: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/18.jpg)
CALCULATIONS
• CURRENT FLOW IN ION CHAMBERS • ION COLLECTION EFFICIENCY IN ION CHAMBERS • LSC EFFICIENCIES • PROPAGATION OF UNCERTAINTY
![Page 19: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/19.jpg)
CALCULATIONS
CURRENT FLOW IN ION CHAMBERS For a 200 cc active volume at STP the ion
chamber current flow is approximately 17 femto-amps for a concentration of 100 uCi/m3
![Page 20: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/20.jpg)
CALCULATIONS PROPAGATION OF UNCERTAINTY
Tritium standard % uncertainty ~ 1.5% Active sample volume % uncertainty ~2% Gamma correction factor & uncertainty ~5% Temperature & Pressure uncertainty ~2% Combined % uncertainty ~ √(1.52 + 22 + 52 + 22) √(2.25 + 4 + 25 + 4) = 5.93 % uncertainty
![Page 21: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/21.jpg)
QUESTIONS ? COMMENTS ?
TOM VOSS NORTHERN NEW MEXICO
[email protected] WWW.VOSS-ASSOCIATES.COM
WWW.HPICORG.COM WWW.AMUG.US
505-920-1470
![Page 22: Tritium Detection Methods and Limitations...Tritium Detection Methods and Limitations Tritium Focus Group Meeting, April 2014 Tom Voss, Northern New Mexico](https://reader033.vdocuments.mx/reader033/viewer/2022053112/608719c242fb3331bd0ee846/html5/thumbnails/22.jpg)
WWW.HPICORG.COM
WWW.AMUG.US