TOP PLAN VIEW MOST TUBE SETTLER MODULES IN UNIT A NOT SHOWN ADSORPTION & FILTER MEDIA IN UNIT A NOT SHOWN MOST UNDERDRAIN LATERALS IN UNIT A NOT SHOWN MOST CLARIFIER MEDIA RETENTION SCREENS IN UNIT A NOT SHOWN REV B SHEET DOCUMENT NUMBER HP51AS-1001 1 OF 4 TITLE GENERAL ARRANGEMENT, HS-2800A, AB TRIDENT HS-2800A WATER TREATMENT SYSTEM 2007-09-11 JA20 SH40 MO96 DESIGNER CHECKER APPROVER THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TO REPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC. DATE C:\Vault\Design\Standard Products\MICROFLOC\TRIDENT HS\TRIDENT HS-2800 Workgroup\Drawing Files\HP51AS-1001.idw 15.7 CU.YD. TYP CONCRETE FILL (BY OTHERS) REFERENCE DOCUMENTS B STANDARD PRODUCT UPDATE P108F16 RE59 DA48 2016-02-05 A REORIENTED TRANSFER PIPING MO96 JA20 2012-03-19 REV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE PREPARED FOR ENGINEER CONTRACTOR PO/CONTRACT NUMBER TRIDENT_ HS PROCESS DESIGN INFORMATION PER UNIT GPM DESIGN FLOW: ADSORPTION CLARIFIER AIR SCOUR FLOW: ADSORPTION CLARIFIER LOADING RATE: CFM GPM/SQ FT FILTER BW FLOW, LOW RATE: FILTER BW FLOW, HIGH RATE: FILTER LOADING RATE: GPM @ 25C GPM/SQ FT 1,400 15 420 5 4,200 1,400 FILTER AIR SCOUR FLOW: 840 CFM GPM @ 25C EST. SHIPPING WEIGHT: EST. OPERATING WEIGHT: TUBE CLARIFIER LOADING RATE: 41,600 456,000 LBS LBS 5 GPM/SQ FT WASTE SUMP, TYP DESIGN BY CONSULTING ENGINEER FLOCCULATED SOLIDS RECIRC PUMP VARIABLE SPEED, TYP *HIDDEN (DASHED) LINES INDICATE REFERENCE COMPONENTS SUPPLIED/DESIGNED BY OTHERS 14'-0" TYP INSIDE TANK WIDTH 20'-0" TYP INSIDE TUBE CLARIFIER LENGTH 6'-8" TYP INSIDE ADSORPTION CLARIFIER LENGTH 20'-0" TYP INSIDE MIXED MEDIA FILTER EFFLUENT PIPING TYP (BY OTHERS) 16" AUTOMATIC BACKWASH INLET BUTTERFLY VALVE, TYP 16" AUTOMATIC BACKWASH SUPPLY HIGH RATE BUTTERFLY VALVE BACKWASH SUPPLY PIPING (BY OTHERS) BACKWASH SUPPLY FLOWMETER (BY OTHERS; NOTE 21) 3" MANUAL SLUDGE BLOWDOWN RATE SET PLUG VALVE, TYP ADSORPTION CLARIFIER MEDIA RETENTION SCREENS, TYP SLUDGE BLOWDOWN PIPING, TYP (BY OTHERS) CLARIFIER TRANSFER PUMP VARIABLE SPEED, TYP 3" AUTOMATIC SLUDGE BLOWDOWN DIAPHRAGM VALVE, TYP TUBE CLARIFIER COLLECTION HEADER & LATERAL, TYP UNIT B INFLUENT FLOWMETER, TYP (NOTE 21) 12" MANUAL TUBE CLARIFIER FLUSH-TO-WASTE BUTTERFLY VALVE, TYP (ROUTE TO WASTE SUMP) 12" MANUAL INFLUENT ISOLATION BUTTERFLY VALVE, TYP FLOCCULATED SOLIDS RECIRC FLOW METER, TYP (NOTE 21) UNIT A 3" AUTOMATIC RECIRC DIAPHRAGM VALVE, TYP 3" RECIRC PUMP DISCHARGE ISOLATION BUTTERFLY VALVE, TYP 3" RECIRC PUMP DISCHARGE CHECK VALVE, TYP FLOCCULATED SOLIDS RECIRC PIPING, TYP (BY OTHERS) INFLUENT PIPING (BY OTHERS) 16" INFLUENT STATIC MIXER COAGULANT INJECTION POINT (BY OTHERS) 8" FILTER AIRWASH CHECK VALVE, TYP 6" CLARIFIER AIRWASH CHECK VALVE, TYP FILTER PLENUM, TYP TUBE CLARIFIER SLUDGE SUCKER COLLECTOR, TYP TUBE CLARIFIER SETTLING TUBE MODULES, TYP 3" TUBE CLARIFIER DRAIN BALL VALVE, TYP 3" AC DRAIN BALL VALVE, TYP AC AIRWASH HEADER AND LATERALS, TYP AC INFLUENT HEADER, TYP CONNECT RECIRC PIPING TO INFLUENT LINE AHEAD OF STATIC MIXER, TYP (BY OTHERS) MULTIBLOCK DIRECT RETENTION UNDERDRAIN, TYP (GROUT BY OTHERS) CLARIFIER TRANSFER PIPING, TYP AUTOMATIC AIR RELEASE VALVE, TYP 6" AUTOMATIC CLARIFIER AIRWASH CONTROL BUTTERFLY VALVE, TYP OVERFLOW AND WASTE PIPING, TYP (BY OTHERS) 12" MODULATING FILTER-TO-WASTE BUTTERFLY VALVE, TYP (ROUTE TO WASTE SUMP) 12" MODULATING EFFLUENT BUTTERFLY VALVE, TYP 12" MODULATING INFLUENT BUTTERFLY VALVE, TYP

Upload: others

Post on 14-Nov-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

TOP PLAN VIEW

MOST TUBE SETTLER MODULES IN UNIT A NOT SHOWN

ADSORPTION & FILTER MEDIA IN UNIT A NOT SHOWN

MOST UNDERDRAIN LATERALS IN UNIT A NOT SHOWN

MOST CLARIFIER MEDIA RETENTION SCREENS IN UNIT A NOT SHOWN

REV

B

SHEETDOCUMENT NUMBER

HP51AS-1001 1 OF 4

TITLE

GENERAL ARRANGEMENT, HS-2800A, AB

TRIDENT® HS-2800A WATER TREATMENT SYSTEM

2007-09-11JA20SH40MO96

DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TO

REPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\Vault\Design\Standard Products\MICROFLOC\TRIDENT HS\TRIDENT HS-2800 Workgroup\Drawing Files\HP51AS-1001.idw

15.7 CU.YD. TYP

CONCRETE FILL

(BY OTHERS)

REFERENCE DOCUMENTS

B STANDARD PRODUCT UPDATE P108F16 RE59 DA48 2016-02-05

A REORIENTED TRANSFER PIPING MO96 JA20 2012-03-19

REV REVISION DESCRIPTION ECN DESIGNER APPROVER DATE

PREPARED FOR

ENGINEER

CONTRACTOR

PO/CONTRACT

NUMBER

TRIDENT HS PROCESS DESIGN INFORMATION PER UNIT

GPMDESIGN FLOW:

ADSORPTION CLARIFIER AIR SCOUR FLOW:

ADSORPTION CLARIFIER LOADING RATE:

CFM

GPM/SQ FT

FILTER BW FLOW, LOW RATE:

FILTER BW FLOW, HIGH RATE:

FILTER LOADING RATE:

GPM @ 25°C

GPM/SQ FT

1,400

15

420

5

4,200

1,400

FILTER AIR SCOUR FLOW: 840 CFM

GPM @ 25°C

EST. SHIPPING WEIGHT:

EST. OPERATING WEIGHT:

TUBE CLARIFIER LOADING RATE:

41,600

456,000

LBS

LBS

5 GPM/SQ FT

WASTE SUMP, TYP

DESIGN BY CONSULTING ENGINEER

FLOCCULATED SOLIDS RECIRC PUMP

VARIABLE SPEED, TYP

*HIDDEN (DASHED) LINES INDICATE REFERENCE COMPONENTS SUPPLIED/DESIGNED BY OTHERS

14'-0" TYP INSIDE

TANK WIDTH

20'-0" TYP INSIDE

TUBE CLARIFIER LENGTH

6'-8" TYP INSIDE

ADSORPTION CLARIFIER® LENGTH

20'-0" TYP INSIDE

MIXED MEDIA FILTER

EFFLUENT PIPING

TYP (BY OTHERS)

16" AUTOMATIC BACKWASH INLET

BUTTERFLY VALVE, TYP

16" AUTOMATIC BACKWASH SUPPLY

HIGH RATE BUTTERFLY VALVE

BACKWASH SUPPLY

PIPING (BY OTHERS)

BACKWASH SUPPLY

FLOWMETER

(BY OTHERS; NOTE 21)

3" MANUAL SLUDGE BLOWDOWN RATE SET

PLUG VALVE, TYP

ADSORPTION CLARIFIER MEDIA RETENTION SCREENS, TYP

SLUDGE BLOWDOWN PIPING,

TYP (BY OTHERS)

CLARIFIER TRANSFER PUMP

VARIABLE SPEED, TYP

3" AUTOMATIC SLUDGE BLOWDOWN

DIAPHRAGM VALVE, TYP

TUBE CLARIFIER COLLECTION

HEADER & LATERAL, TYP

UNIT B

INFLUENT FLOWMETER, TYP

(NOTE 21)

12" MANUAL TUBE CLARIFIER FLUSH-TO-WASTE

BUTTERFLY VALVE, TYP

(ROUTE TO WASTE SUMP)

12" MANUAL INFLUENT ISOLATION

BUTTERFLY VALVE, TYP

FLOCCULATED SOLIDS RECIRC

FLOW METER, TYP (NOTE 21)

UNIT A

3" AUTOMATIC RECIRC

DIAPHRAGM VALVE, TYP

3" RECIRC PUMP DISCHARGE ISOLATION

BUTTERFLY VALVE, TYP

3" RECIRC PUMP DISCHARGE

CHECK VALVE, TYP

FLOCCULATED SOLIDS RECIRC

PIPING, TYP (BY OTHERS)

INFLUENT PIPING

(BY OTHERS)

16" INFLUENT STATIC MIXER

COAGULANT INJECTION POINT (BY OTHERS)

8" FILTER AIRWASH CHECK VALVE, TYP

6" CLARIFIER AIRWASH CHECK VALVE, TYP

FILTER PLENUM, TYP

TUBE CLARIFIER SLUDGE

SUCKER™ COLLECTOR, TYP

TUBE CLARIFIER SETTLING TUBE MODULES, TYP

3" TUBE CLARIFIER DRAIN

BALL VALVE, TYP

3" AC DRAIN BALL VALVE, TYP

AC AIRWASH HEADER

AND LATERALS, TYP

AC INFLUENT HEADER, TYP

CONNECT RECIRC PIPING TO INFLUENT

LINE AHEAD OF STATIC MIXER, TYP

(BY OTHERS)

MULTIBLOCK® DIRECT RETENTION

UNDERDRAIN, TYP

(GROUT BY OTHERS)

CLARIFIER TRANSFER PIPING, TYP

AUTOMATIC AIR RELEASE VALVE, TYP

6" AUTOMATIC CLARIFIER AIRWASH CONTROL

BUTTERFLY VALVE, TYP

OVERFLOW AND WASTE PIPING, TYP

(BY OTHERS)

12" MODULATING FILTER-TO-WASTE

BUTTERFLY VALVE, TYP

(ROUTE TO WASTE SUMP)

12" MODULATING EFFLUENT

BUTTERFLY VALVE, TYP

12" MODULATING INFLUENT

BUTTERFLY VALVE, TYP

UNIT A TRANSFER AND WASTE SIDE ELEVATION VIEW

UNIT B TRANSFER AND WASTE SIDE ELEVATION VIEW

REV

B

SHEETDOCUMENT NUMBER

HP51AS-1001 2 OF 4

TITLE

GENERAL ARRANGEMENT, HS-2800A, AB

TRIDENT® HS-2800A WATER TREATMENT SYSTEM

2007-09-11JA20SH40MO96

DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TO

REPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\Vault\Design\Standard Products\MICROFLOC\TRIDENT HS\TRIDENT HS-2800 Workgroup\Drawing Files\HP51AS-1001.idw

*HIDDEN (DASHED) LINES INDICATE REFERENCE COMPONENTS SUPPLIED/DESIGNED BY OTHERS

6" TYP HEIGHT

EQUIPMENT PAD

(BY OTHERS; NOTE 2)

2'-9" TYP

INFLUENT

8'-2

3

4

" TYP

TUBE CLARIFIER

TRANSFER

1'-1" TYP

EFFLUENT, BACKWASH

SUPPLY, AIRWASH SUPPLY,

AND FILTER TO WASTE

6'-5" TYP

WASTE

9'-2

1

8

" TYP

OVERFLOW

10'-

5

16

" TYP

OUTSIDE TUBE

CLARIFIER TRANSFER

23'-4

5

8

" TYP OUTSIDE

ADSORPTION CLARIFIER INFLUENT

18'-11

5

16

" TYP

OUTSIDE OVERFLOW AND WASTE

46'-9

1

4

" TYP LENGTH

OUTSIDE TANK WALLS

47'-9

1

4

" TYP LENGTH

OUTSIDE TANK STIFFENERS

46'-10

5

8

" TYP

BASE PLATE LENGTH

PLANT EFFLUENT GRAVITY DISCHARGE

WITH WATER SEAL (BY OTHERS; NOTE 4)

1'-9

1

4

" TYP

ADSORPTION

CLARIFIER INFLUENT

2'-1" TYP

SLUDGE SUCKER WASTE

9'-

5

16

" TYP

OUTSIDE SLUDGE

SUCKER WASTE

5'-

3

16

" TYP

FLOCCULATED SOLIDS

RECIRC CONNECTION

3'-0"

MAXIMUM CLEARWELL

WATER ELEVATION

(GRAVITY DISCHARGE; NOTE 4)

COVERED SLUDGE SUCKER

DRIVE UNIT, TYP

TUBE CLARIFIER SAMPLE TAPS AND SINK, TYP

2" RECIRC PUMP ISOLATION

PVC BALL VALVE, TYP

FLOCCULATED SOLIDS RECIRC PUMP

VARIABLE SPEED, TYP

CONNECT RECIRC PIPING TO INFLUENT

LINE AHEAD OF STATIC MIXER, TYP

(BY OTHERS)

STATIC MIXER

RECIRC PIPING

(BY OTHERS)

INLET PRESSURE DESIGN:

20-30 FT MAXIMUM

AT STATIC MIXER

CLARIFIER TRANSFER PUMP

VARIABLE SPEED, TYP

CLARIFIER PRESSURE SWITCH

ASSEMBLY, TYP

INTER-CLARIFIER TURBIDIMETER ASSEMBLY, TYP

POLYMER INJECTION POINT, TYP

FILTER LEVEL

TRANSMITTER, TYP

TUBE CLARIFIER LEVEL

TRANSMITTER, TYP

POLYMER INJECTION POINT, TYP

12" MANUAL CLARIFIER TRANSFER

PUMP SUCTION ISOLATION

BUTTERFLY VALVE, TYP

1

1

2

" FNPT SINK DRAIN CONNECTION

(ROUTE TO WASTE SUMP)

12" AUTOMATIC CLARIFIER TRANSFER CONTROL

BUTTERFLY VALVE, TYP

INFLUENT END ELEVATION

EFFLUENT END ELEVATION

REV

B

SHEETDOCUMENT NUMBER

HP51AS-1001 3 OF 4

TITLE

GENERAL ARRANGEMENT, HS-2800A, AB

TRIDENT® HS-2800A WATER TREATMENT SYSTEM

2007-09-11JA20SH40MO96

DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TO

REPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

C:\Vault\Design\Standard Products\MICROFLOC\TRIDENT HS\TRIDENT HS-2800 Workgroup\Drawing Files\HP51AS-1001.idw

NOTES:

1.) EQUIPMENT FURNISHED BY WESTECH IS DESCRIBED IN A SEPARATE EQUIPMENT LIST.

ADDITIONAL PIPING, PIPE SUPPORTS, AND CONNECTION FITTINGS, AIR PIPING, CONDUIT,

WIRING AND MOTOR CONTROL CENTER ARE NOT INCLUDED WITH STANDARD UNIT.

MAJOR EQUIPMENT AND COMPONENTS TO BE INSTALLED AT THE JOBSITE BY THE

INSTALLING CONTRACTOR.

2.) EQUIPMENT PAD DESIGN IS THE RESPONSIBILITY OF THE CONSULTING ENGINEER.

CONSTRUCTION OF EQUIPMENT PAD IS BY OTHERS.

3.) PIPE SUPPORTS ARE NOT SHOWN. SUPPORTS TO BE DESIGNED BY THE CONSULTING

ENGINEER AND SUPPLIED BY THE INSTALLING CONTRACTOR. DO NOT SUPPORT PIPING

OR OTHER STRUCTURES FROM THE TANK OR TANK PROJECTIONS.

4.) DESIGN AND APPLICATION FEATURES ARE DESCRIBED IN TYPICAL SPECIFICATION

SHEETS, TECHNICAL DATA SHEET, FLOW SCHEMATIC, ELECTRICAL DIAGRAM AND

ELECTRICAL SCHEMATIC. ARRANGEMENT SHOWN IS FOR GRAVITY DISCHARGE TO

BELOW-GRADE FINISHED WATER STORAGE.

5.) THE STANDARD DESIGN IS FOR INDOOR INSTALLATION.

6.) EITHER CHECK VALVES OR BACKFLOW PREVENTERS ARE REQUIRED IN BACKWASH

LINES AND FURNISHED BY OTHERS (NOT SHOWN ON DRAWING).

7.) AUTOMATIC RATE OF FLOW CONTROL LOOPS ON EACH INFLUENT LINE MAINTAIN THE

PRE-SET FLOW TO EACH UNIT. FLOW SET POINTS INTERLOCKED WITH FLUSHING AND

BACKWASHING CYCLE.

8.) FILTER LIQUID LEVEL CONTROLLERS OPERATE FILTER EFFLUENT AND

FILTER-TO-WASTE MODULATING VALVES TO MAINTAIN CONSTANT FILTER LEVEL.

9.) FILTER CONTROL CIRCUITS PROVIDE FOR AUTOMATIC FLUSH/BACKWASH CYCLE WITH

RETURN TO OPERATING SERVICE, INITIATED BY TIME CLOCK, HIGH HEADLOSS, OR

MANUAL PUSHBUTTON.

10.) THREE LEVEL SWITCHES WITH DRY CONTACTS SHOULD BE PROVIDED BY THE

CUSTOMER AND INSTALLED IN THE FINISHED WATER STORAGE TANK FOR THE

AUTOMATIC OPERATION OF THE TRIDENT HS UNITS. ONE HIGH LEVEL SWITCH WILL STOP

THE UNITS, ONE MID LEVEL SWITCH WILL START THE UNITS AND ONE LOW LEVEL SWITCH

WILL SERVE AS A MINIMUM LEVEL TO ENABLE THE BACKWASH PROCESS.

11.) THE HIGH LEVEL STOP AND THE MID LEVEL START SWITCHES SHOULD BE INSTALLED

WITH SUFFICIENT VOLUME BETWEEN THEM TO PREVENT EXCESSIVE CYCLING OF THE

TRIDENT HS UNITS.

12.) THE LOW LEVEL BACKWASH ENABLE SWITCH SHOULD BE INSTALLED WHERE THE

MINIMUM VOLUME IN THE BACKWASH SUPPLY TANK IS ADEQUATE TO PROVIDE A

BACKWASH WITHOUT PULLING AIR INTO THE BACKWASH SUPPLY PUMP. THE MAXIMUM

WATER TEMPERATURE SHOULD BE CONSIDERED WHEN CALCULATING THE MINIMUM

BACKWASH VOLUME OR LEVEL IN THE TANK.

13.) AIRWASH BLOWERS ARE NOT SHOWN.

14.) AIR COMPRESSOR FOR VALVE OPERATION IS NOT SHOWN.

15.) AN AIR RELEASE VALVE IS REQUIRED AT HIGH POINTS OF ANY WATER SUPPLY LINE

(I.E. INFLUENT; BACKWASH) TO VENT ACCUMULATED AIR. THE VALVE(S) ARE TO BE SIZED

TO ALLOW THE COMPLETE VOLUME OF THE SUPPLY LINE FROM SOURCE TO UNIT, TO BE

VENTED IN 20 SECONDS WITH DIFFERENTIAL OF APPROXIMATELY 10 PSIG, AND BE

CAPABLE OF CONTINUOUSLY VENTING ACCUMULATED AIR (BY OTHERS). FOR

INSTALLATION UTILIZING VERTICAL TURBINE OR "CAN-TYPE" PUMPS, A SEPARATE

"TURBINE AIR VALVE" IS REQUIRED TO VENT THE AIR CONTENTS OF THE PUMPED

COLUMN WITHOUT LETTING THE AIR INTO THE SUPPLY PIPING (BY OTHERS).

16.) TANKS ARE FURNISHED WITH FINISH COATING SUITABLE FOR POTABLE WATER

APPLICATIONS ON INTERIOR; PRIMER ON EXTERIOR. TANK BASE PLATE BOTTOM IS

UNPAINTED FOR INSTALLATION ON COAL TAR OR ASPHALTIC TYPE BASE MASTIC

COMPOUND (BY OTHERS). TRIDENT HS UNITS SHOULD BE LEVEL WITHIN ONE EIGHTH

INCH IN TEN FEET AT TIME OF INSTALLATION.

17.) OPTIONAL EQUIPMENT TO SUIT PROJECT REQUIREMENTS IS AVAILABLE. TYPICAL

PROCESS EQUIPMENT OPTIONS INCLUDE: ADDITIONAL CHEMICAL FEED SYSTEMS,

INFLUENT TURBIDITY RECORDERS, INFLUENT STREAMING CURRENT MONITOR,

PLATFORM/WALKWAY CLIPS.

18.) CONSULT FACTORY FOR OTHER INFLUENT FLOW CONTROL OPTIONS.

19.) ALTERNATE CHEMICAL FEED SYSTEMS ARE AVAILABLE. CONSULT FACTORY FOR

RECOMMENDATIONS.

20.) ALL TANK FLANGED CONNECTIONS, EXCEPT OVERFLOW, EXTEND 6" FROM SHELL OF

TANK.

21.) LOCATION OF FLOW METERS ARE TO BE PER FLOWMETER MANUFACTURER'S

WRITTEN RECOMMENDATIONS CONFIRMED BY THE CONSULTING ENGINEER. GROUNDING

RINGS ARE BY OTHERS, IF REQUIRED.

22.) ELEVATION AND HEIGHT DIMENSIONS ARE CALCULATED FROM THE BOTTOM OF THE

TANK BASE PLATE.

23.) THE DESIGN BACKWASH RATE LISTED IS BASED ON A TEMPERATURE OF 25 DEGREES

CELSIUS. THE ACTUAL BACKWASH WATER RATE MUST BE ADJUSTED 2% UP OR DOWN

FOR EACH DEGREE CELSIUS DIFFERENCE ABOVE OR BELOW FROM DESIGN

TEMPERATURE; I.E. IF ABOVE 25°C, INCREASE BY 2%; IF BELOW 25°C, DECREASE BY 2%.

1'-10

3

16

" TYP OUTSIDE

AIRWASH SUPPLY

7'-

5

16

" TYP

OUTSIDE, TANK

2'-2

3

4

" TYP OUTSIDE

OVERFLOW AND WASTE

4'-8

3

4

"

TYP

3'-11

3

4

"

TYP

UNIT A

UNIT B

FILTER HEADLOSS

SWITCH ASSEMBLY,

TYP

CROSSWALK & ACCESS LADDER

DESIGN BY CONSULTING ENGINEER

(SUPPLIED BY OTHERS)

16" AUTOMATIC BACKWASH

SUPPLY HIGH RATE

BUTTERFLY VALVE

EFFLUENT TURBIDIMETER ASSEMBLY

WITH SAMPLE PUMP, TYP

FROM BACKWASH SUPPLY PUMP

(PUMP AND PIPING BY OTHERS)

FLOCCULATED SOLIDS RECIRC

SAMPLE TAP, TYP (BY OTHERS)

8" FILTER AIRWASH

CHECK VALVE, TYP

UNIT BUNIT A

3'-4

3

4

"

4'-0"

BETWEEN

TANKS

15'-4

3

4

" TYP OUTSIDE

OVERALL SHIPPING WIDTH

14'-

5

8

" TYP OUTSIDE

TANK WALLS WIDTH

10'-

1

2

" TYP

TANK HEIGHT

13'-3

3

4

" TYP OVERALL

INSTALLED HEIGHT

PROXIMITY

SWITCH

CABLES

6'-1

5

16

" TYP

OUTSIDE, LEFT

1'-10" TYP

9'-11

5

16

" 8'-1

5

16

"

6'-1

5

16

"

TYP

7'-11

5

16

" TYP

OUTSIDE, RIGHT

18'-

5

8

"

TANK SPACING

14'-2" TYP

BASE PLATE WIDTH

*HIDDEN (DASHED) LINES INDICATE REFERENCE COMPONENTS SUPPLIED/DESIGNED BY OTHERS

2'-9" TYP

INFLUENT

5'-

3

16

" TYP

FLOCCULATED SOLIDS

RECIRC PUMP

CONNECTION

1'-1"

TYP

8" MANUAL BACKWASH LOW RATE

CONTROL BUTTERFLY VALVE

18" AUTOMATIC WASTE

BUTTERFLY VALVE, TYP

8" AUTOMATIC FILTER AIRWASH CONTROL

BUTTERFLY VALVE, TYP

16" MANUAL BACKWASH HIGH RATE

CONTROL BUTTERFLY VALVE

12" MODULATING FILTER-TO-WASTE

BUTTERFLY VALVE, TYP

12" MODULATING EFFLUENT

BUTTERFLY VALVE, TYP

16" AUTOMATIC BACKWASH INLET

BUTTERFLY VALVE, TYP

ISOMETRIC: INFLUENT/RIGHT

ISOMETRIC: EFFLUENT/LEFT

C:\Vault\Design\Standard Products\MICROFLOC\TRIDENT HS\TRIDENT HS-2800 Workgroup\Drawing Files\HP51AS-1001.idw

REV

B

SHEETDOCUMENT NUMBER

HP51AS-1001 4 OF 4

TITLE

GENERAL ARRANGEMENT, HS-2800A, AB

TRIDENT® HS-2800A WATER TREATMENT SYSTEM

2007-09-11JA20SH40MO96

DESIGNER CHECKER APPROVER

THIS DRAWING IS PROPERTY OF WESTECH ENGINEERING, INC. AND IS TRANSMITTED IN CONFIDENCE. NEITHER RECEIPT NOR POSSESSION CONFERS OR TRANSFERS ANY RIGHTS TO

REPRODUCE, USE, OR DISCLOSE, IN WHOLE OR IN PART, DATA CONTAINED HEREIN FOR ANY PURPOSE, WITHOUT THE WRITTEN PERMISSION OF WESTECH ENGINEERING, INC.

DATE

*HIDDEN (DASHED) LINES INDICATE REFERENCE COMPONENTS SUPPLIED/DESIGNED BY OTHERS