trident auto drain
TRANSCRIPT
Series LDV
� Zero Air Loss
� Noise Free
� Condensate Sensing Type
� Design Patented
Lasting Values
Automatic Drain Valves
Ind ia ’s La rges t Expor te r o f Compressed A i r Trea tment P roduc ts
Application
Air Receivers Refrigerated Dryers Drop Legs Filters / Seperators
Technical Specifications
ModelSpecification
LDV-1000 LDV-2000 LDV-3000
Maximum Working Pressure 10 Kg/cm2 16 Kg/cm2 16 Kg/cm2
Minimum Working Pressure 2 Kg/cm2 2 Kg/cm2 2 Kg / cm2
Maximum discharge Quantity 25 litres/hr 135 litres/hr 535 litres/hr
Capacity upto 250 cfm upto 1000 cfm upto 2000 cfm
Weight 1.25 Kg 3 Kg 12 Kg
Fluid Temperature 75oC 75oC 75oC
Class of protection IP55 IP55 IP55
End connection Inlet ½” (F) BSP ½” (M) BSP ½” (M) BSP
End connection Outlet 6mm Hose barb ½” (F) BSP ½” (F) BSP
Voltage 85 to 135 V AC 85 to 135 V AC 85 to 135 V AC
Power consumption 12 Watts 12 Watts 12 Watts
Test/Manual override button � � �
Intelligent Controller � � �
Dimension L x B x H (mm) 115 x 100 x 100 170 x 220 x 260 270 x 270 x 410
Valve orifice 4 mm 8 mm 8 mm
The LDV Series
Trident’s condensate sensing type automatic drain valve is
the latest advancement in drain valve technology. Instead of
operating through cycle timer, these valves sense the
condensate level for activation, ensuring absolutely no loss of
compressed air and hence enormous energy saving. Trident
condensate sensing type drain valves are highly efficient and
reliable. These drain valves can be fitted directly on the
equipment simply by replacing the manual drains.
Features
� The electronic level control ensures proper draining of condensate and avoids unnecessary loss of air.
� All the functions of the valve are accurately indicated by the LED display.
� Test switch (or) manual drain allows function test at anytime.
� Intelligent Controller detects valve, probe failure and acts accordingly.
� Noise free, as air is not discharged.
Manufacturing Facility Our Presence
04 /
07
Our other Range of Products
� Time based Auto Drain Valve � Desiccant Dryer (Heatless)� Blower Reactivated Dryer � Refrigeration Type Dryer
� Submicron Filter � Moisture Separator
Trident Pneumatics Pvt Ltd Trident Pneumatics Pvt Ltd Trident Pneumatics Sdn Bhd5/232, K.N.G. Pudur Road, Coimbatore - 641 108, India. Shanghai, China. Selangor, Malaysia.
Ph : +91-422-2400492 Fax : +91-422-2401376
e-mail : [email protected] Website : www.tridentpneumatics.com
Sales & Ahmedabad Baroda Bangalore Chennai Delhi Hyderabad Kolkatta Mumbai PuneService Outlets 98259 26342 98795 16299 98450 93322 98400 97782 98113 10726 98854 45321 24071900 25434551 27471877
Series CTDEasy to mount at all locationsMaintain and clean drain valve without removing from serviceOn and Off timing adjustableLarge orifice for effective drain of dust and condensateCondensate discharging is no more problemDesign Patented
India’s Largest Exporter of Compressed Air Treatment Products
Automatic Drain Valves
Lasting Value
CTD 11
CTD 11-B
CTD HD
Online service & Manual Drain
Our Other Range of Products Level Sensing Auto Drain Valve Desiccant Dryer (Heatless)
Desiccant Dryer (Heated) Refrigeration Dryers Submicron Filter Moisture Separator
Manufacturing Facility
Our Presence
NEW COMPACT TIMER DRAINModel - CTD
Air Receivers Drop Legs Refrigerated Dryers Filters / Seperators
Specifications : CTD 11 CTD 11-B CTD HD
Voltage ............................................ 230 V AC / 50 Hz / 1 Ph ............................................Power 8 Watts Max 15 watts Max 8 Watts MaxProtection ............................................................ IP 55 ............................................................Elec. Connection ................................................... DIN 43650 Micro ...................................................Inlet 1/8” BSP (F) 1/2” BSP (F) 1/2” BSP (F)Outlet 10 mm Hose Barb 1/2” BSP (F) 1/2” BSP (F)Pressure ........................................................ 16 bar (g) ........................................................Valve Orifice 2.5 mm 4 mm 8 mmTiming ..................................... Cycle : 1 min to 60 min Adjustable .....................................
..............................................Drain : 1 sec to 20 Sec ..............................................Body Brass & moving parts SS ........... Aluminium & moving parts SS ..................Compressor Capacity Upto 100 cfm Upto 500 cfm Upto 1000 cfmOperating Temp ......................................................... 0 – 70OC .........................................................Maximum discharge 100 litres / hour at 150 litres / hour 200 litres / hour
7 bar (g) of condensate at 7 bar (g) at 7 bar (g)Control ................................................ Microcontroller based ................................................On line service ............................ Yes : Integrated Mechanical + Electronic Flush ............................Weight 250 Grams 350 Grams 450 GramsDimensions (L x B x H) 78 x 70 x 63 78 x 70 x 100 78 x 70 x 100
Applications :
CTD is the culmination of years of manufacturing drains.It takes care of all problems normally associated withdrains. The controller is now built of ultra reliablemicrocontroller and feature dual adjustment of bothcycle and drain. The valve has a large orifice and specialsolenoid operator section to discharge dust.
Should the valve still get clogged you can serviceit without removing from the installation. Press theknob at the bottom of the valve to mechanically clearall the sludge. Electronically flush a few times and nowit is fully serviced and ready for use.
Condensate discharge for any other pressure (P) multiply the flow given for 7 Kg/cm2 (g) by P——2.6
11 /
07
Trident Pneumatics Pvt Ltd Trident Pneumatics Pvt Ltd Trident Pneumatics Sdn Bhd5/232, K.N.G. Pudur Road, Coimbatore - 641 108, India. Shanghai, China. Selangor, Malaysia.
Ph : +91-422-2400492 Fax : +91-422-2401376
e-mail : [email protected] Website : www.tridentpneumatics.com
Sales & Ahmedabad Bangalore Chennai Delhi Hyderabad Kolkatta Mumbai PuneService Outlets 98259 26342 98450 93322 99949 78928 98113 10726 98854 45321 24071900 25434551 27471877
18
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
Cond
ensa
te d
rain
sCo
nden
sate
dra
ins
AOK 20B
Automatic condensate drain - 20 bar
AOK 20B - Automatic Condensate Drain
The AOK 20 is used when larger amounts of condensate (up to 300 l/h) must be automatically discharged from � lters, pressure vessels and cyclone separators. It ensures reliable operation up to 20 barg (290 psig). When the condensate exceeds the discharge level, the � oat rises, opens the discharge aperture and discharges condensate from the system. We reccomend the installation of the nipple, which improves the performance of the AOK 20B.
Technical data- material: aluminium alloy- operating temperature range: 1,5 to 65 °C (35 to 149 °F)- operating pressure range: 0 - 20 bar (0 - 290 psi)- connection: R 1/2’’- oil resistant o-ring
132130
107
1/2’’