triad 12th avenue - pavilion construction 12th aveneu apts... · fire resistance treated feet...
TRANSCRIPT
LC
LC
SD
ABBREVIATIONSA/CABVADDLADJAFFALTAPPROXAPTARCHAWN
AIR CONDITIONINGABOVEADDITIONALADJUSTABLEABOVE FINISHED FLOORALTERNATEAPPROXIMATE(LY)APARTMENTARCHITECT(URAL)AWNING
BABDBFBLDGBLKGBMBOBSMTBTW
BATHBEDROOMBARRIER FREEBUILDINGBLOCKINGBEAMBOTTOM OFBASEMENTBETWEEN
CABCBCIPCLCLCLGCLRCMUCOLCONCCONSTRCONTCOORDCORRCPTCSMT
CABINETCATCH BASINCAST IN PLACECENTERLINECLOSETCEILINGCLEARCONCRETE MASONRY UNITCOLUMNCONCRETECONSTRUCTIONCONTINUOUSCOORDINATECORRIDORCARPETCASEMENT
DEMODIADNDRDSDTLD/WDWG
DEMOLISHDIAMETERDOWNDOORDOWNSPOUTDETAILDISHWASHERDRAWING
(E)EEAEIFS
ELELEVENCLEJEOEQEXHEXT
EXISTINGEASTEACHEXTERIOR INSULATION + FINISH SYSTEMELEVATIONELEVATOR, ELEVATIONENCLOSUREEXPANSION JOINTEDGE OFEQUALEXHAUSTEXTERIOR
FDFDNFEFFFINFLRFOFPLFRTFTFTGFURN
FLOOR DRAINFOUNDATIONFIRE EXTINGUISHERFINISHED FLOORFINISHEDFLOORFACE OFFIREPLACEFIRE RESISTANCE TREATEDFEETFOOTINGFURNITURE, FURNACE
GAGALVGCGLGSFGWB
GAUGEGALVANIZEDGENERAL CONTRACTORGLASSGROSS SQUARE FEETGYPSUM WALLBOARD
HHBHDRHDWDHGTHORHRHVAC
HIGHHOSE BIBHEADERHARDWOODHEIGHTHORIZONTALHOURHEATING, VENTILATION,AND AIR CONDITIONING
IDININCLINSINSULINT
INSIDE DIAMETERINCHINCLUDED. INCLUDINGINSULATIONINSULATIONINTERIOR
LLAMLAVLBLRG
LONG, LEFTLAMINATEDLAVATORYPOUNDLARGE
MATLMAXMECHMEDMEZZMFGMFGRMINMISC
MATERIALMAXIMUMMECHANICALMEDIUMMEZZANINEMANUFACTURERMANUFACTURERMINIMUMMISCELLANEOUS
(N)NN/ANICNONSFNTS
NEWNORTHNOT APPLICABLENOT IN CONTRACTNUMBERNET SQUARE FEETNOT TO SCALE
OCOCCODOFFOPPOVHD
ON CENTEROCCUPANCYOUTSIDE DIAMETEROFFICEOPPOSITEOVERHEAD
PERFPERIMPERMPLPLAMPLYWDPRPRELIMPKGPROJPROPPSIPT
PERFORATEDPERIMETERPERMEABLE, PERMANENTPROPERTY LINEPLASTIC LAMINATEPLYWOODPAIRPRELIMINARYPARKING, PACKAGEPROJECTPROPERTYPOUNDS/SQUARE INCHPRESSURE TREATED,POST TENSIONED
RR/ARADRCRCPRDREFREQREVRMRO
RISERRETURN AIRRADIUSRESILIENT CHANNELREFLECTED CEILING PLANROOF DRAINREFRIGERATORREQUIREDREVERSE, REVISIONROOMROUGH OPENING
SS/ASFSHTSIMSMSPSPECSPKLRSQSSSTLSTCSTORSTRUCT
SOUTHSUPPLY AIRSQUARE FEETSHEETSIMILARSMALLSTANDPIPESPECIFICATIONSPRINKLERSQUARESANITARY SEWER, STAINLESS STEELSTEELSOUND TRANSMISSION COEFFICIENTSTORAGESTRUCTURE, STRUCTURAL
TTBDTELTEMPTGT>HTOTOTYP
TREADTO BE DETERMINEDTELEPHONETEMPORARYTEMPERED GLAZINGTONGUE & GROOVETHICK(NESS)TOTALTOP OFTYPICAL
UNOUTIL
UNLESS NOTED OTHERWISEUTILITY
VCTVERTVIFVIN
VINYL COMPOSITION TILEVERTICALVERIFY IN FIELDVINYL
WW/W/DW/OWCWDWHWIN
WEST, WIDEWITHWASHER/DRYERWITHOUTWATER CLOSETWOODWATER HEATERWINDOW
LEVEL
LEVEL 7
LEVEL 6
LEVEL 5
LEVEL 4
LEVEL 3
LEVEL 2
LEVEL 1
ROOF
TOTAL
F.A.R.
FLOOR AREA RATIO MATRIX*THIS TABLE IS BASED ON THE SMC 23.84A.012DEFINITION OF GROSS FLOOR AREA.
32,827 SF
4,714 SF
4,622 SF
4,237 SF
398 SF
*SEE SHEET A0.2 FOR FAR CALCULATIONS
4,714 SF
4,714 SF
4,714 SF
4,714 SF
SYMBOLS
SECTION OR DETAILREFERENCE
ELEVATION REFERENCE
DETAIL REFERENCE
SPOT ELEVATION
DATUM
CUT MARK
CENTERLINE
REVISION CLOUD ANDTAG
NORTH ARROW
NORTH
RAMP ARROW WITHPERCENT SLOPE
DECK OR ROOF SLOPE
WALL/FLOORASSEMBLY TYPETAG
ROOF PITCHRISE:RUN
OR
WINDOW TAG
DOOR TAG
SMOKE ALARM
FIRE EXTINGUISHER
BARRIER FREE SYMBOL
GARAGE DRAIN
OR DECK OR ROOF DRAIN
ROOF DRAIN WITHOVERFLOW DRAIN
EXHAUST FAN
FAN TERMINATION
DOOR THRESHOLDHEIGHT
FLOORING TRANSITION
EXIT LIGHTING
EXIT SIGN
HOSE BIBH.B.
TC TRASH CHUTE
SOFFIT ABOVE, OF DUCTS ABOVE
GRID LINE
WATER HEATERW/ OVERFLOW PAN
WH
1A1.0
1A1.0
1A1.0
1A1.0
ELEV. 111'-0"T.O. PARAPET
FLOOR LEVELELEV. 111'-0"
1
2
A1
A
2
1/2"
2%
2:12
126
DRAWING TITLEDRAWING SCALE
CARPETVINYL
RAMP UP5%
2A-FE
WHOLE HOUSE FANWHF
EXIT
GRAB BAR BLOCKING SCUPPER
CLOTHES ROD + SHELF
OWNER:TRIAD CAPITAL PARTNERS2801 ALASKAN WAY, STE 107SEATTLE, WA 98121CONTACT: BRETT ALLEN(P) 206.374.0414(F) 206.374.0415(E) [email protected]
ARCHITECT/APPLICANT:NICHOLSON KOVALCHICK ARCHITECTS4302 SW ALASKA STREET, SUITE #200SEATTLE, WA 98116CONTACT: MICHAEL GODFRIED(P) 206.933.1150(F) 206.933.1154(E) [email protected]
GEOTECHNICAL ENGINEER:GEOTECH CONSULTANTS, INC.13256 NE 20TH ST, STE 16BELLEVUE, WA 98005CONTACT: JAMES STRANGE(P) 425.747.5618(E) [email protected]
SURVEYOR:PACE ENGINEERS, INC.11255 KIRKLAND WAY, STE 300SEATTLE, WA 98033CONTACT: BILL HAWKINS(P) 425.827.2014(F) 425.827.5043(E) [email protected]
LANDSCAPE ARCHITECT:KAREN KIEST LANDSCAPE ARCHITECTS111 W JOHN ST, STE 305SEATTLE, WA 98119CONTACT: KAREN KIEST(P) 206.323.6032(E) [email protected]
SHORING ENGINEER:CT ENGINEERING, INC.180 NICKERSON STREET, STE 302SEATTLE, WA 98109CONTACT: CRAIG ROBERTS(P) 206.285.4512(F) 206.285.0618(E) [email protected]
STRUCTURAL ENGINEER:DCI ENGINEERS818 STEWART ST, STE 1000SEATTLE, WA 98101CONTACT: CRAIG STAINER(P) 206.332.1900(E) [email protected]
CIVIL ENGINEER:PACE ENGINEERING11255 KIRKLAND WAY, STE 300KIRKLAND, WA 98033CONTACT: JOHN WEED(P) 425.827.2014(E) [email protected]
ELECTRICAL ENGINEER:ADVANCED ELECTRICAL SERVICES, INC.192 NICKERSON STREET, SUITE 306SEATTLE, WA 98109CONTACT: BUD REICHARD(P) 206.282.6364(E) [email protected]
ENERGY CONSULTANT:360 ANALYTICS12354 16TH AVENUE NESEATTLE, WA 98125CONTACT: DAVID REDDY(P) 206.420.7918(E) [email protected]
MECHANICAL/PLUMBING ENGINEER:HV ENGINEERING, INC.7100 LINDEN AVENUE N, SUITE #1SEATTLE, WA 98103CONTACT: BRIAN ROETCISOENDER(P) 206.706.9669(E) [email protected]
INTERIOR DESIGN CONSULTANT:VIDA DESIGN107 SE WASHINGTON ST., SUITE 248PORTLAND, OR 97214CONTACT: RACHEL SOWIEJA(P) 503.381.7877(E) [email protected]
BUILDING ENVELOPE CONSULTANT:JRS ENGINEERING CORP.9750 3RD AVENUE NE, SUITE 101SEATTLE, WA 98115CONTACT: CAELUM ROBERTS(P) 206.728.2358(E) [email protected]
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A0.0
115205.22.2013
AMMG1152_TRIAD 12TH
TITLE SHEET -DRAWING INDEX,PROJECT INFO.
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
ARCHITECTURAL SHEET INDEX
A0.0 TITLE SHEET - DRAWING INDEX, PROJECT INFO. 05.22.2013A0.1 GENERAL NOTES 05.22.2013A0.2 ZONING 05.22.2013A0.3 BUILDING CODE - ANALYSIS + DIAGRAMS 05.22.2013A0.4 BUILDING CODE - ANALYSIS + DIAGRAMS 05.22.2013A1.0 SITE PLAN - EXISTING 05.22.2013A1.1 SITE PLAN - NEW 05.22.2013A2.0 FLOOR PLAN - BASEMENT 05.22.2013A2.1 FLOOR PLAN - LEVEL 1 05.22.2013A2.2 FLOOR PLAN - LEVEL 2 05.22.2013A2.3 FLOOR PLAN - LEVELS 3-7 05.22.2013A2.4 FLOOR PLAN - ROOF 05.22.2013A3.0 ELEVATION - SOUTH + EAST 05.22.2013A3.1 ELEVATION - NORTH + WEST 05.22.2013A4.0 SECTION - E/W + N/S 05.22.2013A5.0 AMENITY PLAN 05.22.2013A5.1 UNIT PLANS 05.22.2013A5.2 UNIT PLANS 05.22.2013A5.3 UNIT PLANS 05.22.2013A5.4 TRANSFORMER PLANS + SECTIONS 05.22.2013A6.0 INTERIOR ELEVATIONS (BATHROOMS) 05.22.2013A6.1 INTERIOR ELEVATIONS (KITCHENS) 05.22.2013A7.0 STAIR + ELEV NOTES 05.22.2013A7.1 STAIR A 05.22.2013A7.2 STAIR B 05.22.2013A8.0 WALL SECTIONS 05.22.2013A9.0 DETAILS - CONCRETE 05.22.2013A9.1 DETAILS - EXTERIOR WALLS 05.22.2013A9.2 DETAILS - EXTERIOR WALLS 05.22.2013A9.3 DETAILS - EXTERIOR WALLS 05.22.2013A9.4 DETAILS - WINDOWS + SLIDERS 05.22.2013A9.5 DETAILS - WINDOWS + STOREFRONT 05.22.2013A9.6 DETAILS - WINDOWS + STOREFRONT 05.22.2013A9.7 DETAILS - INTERIOR WALLS 05.22.2013A9.8 DETAILS - STAIR + ELEV 05.22.2013A9.9 DETAILS - DOORS 05.22.2013A9.10 DETAILS - ROOF 05.22.2013A9.11 DETAILS - ATTACHMENTS 05.22.2013A9.12 STAIR ROOF CANOPIES 05.22.2013A9.13 FIBER CEMENT SIDING REVEAL DETAILS 05.22.2013A9.14 LEED COMPARTMENT- ALIZATION DIAGRAMS +
NOTES05.22.2013
A10.0 INTERIOR ASSEMBLIES 05.22.2013A10.1 EXTERIOR ASSEMBLIES 05.22.2013A10.2 ROOF + FLOOR ASSEMBLIES 05.22.2013A10.3 DOOR SCHEDULE 05.22.2013A10.4 WINDOW SCHEDULE 05.22.2013
LANDSCAPE SHEET INDEX
L1.1 LANDSCAPE PLAN 05.22.2013L1.2 LANDSCAPE DETAILS 05.22.2013L1.3 SEATTLE GREEN FACTOR CALCULATIONS 05.22.2013L2.1 IRRIGATION PLAN 05.22.2013L2.2 IRRIGATION DETAILS 05.22.2013
SURVEY SHEET INDEX
1 ALTA - TOPOGRAPHIC SURVEY 02.02.20122 ALTA - TOPOGRAPHIC SURVEY 02.02.2012
CIVIL SHEET INDEX
C0.0 GENERAL NOTES 05.22.2013C1.0 DEMOLITION AND TESC PLAN 05.22.2013C2.0 GRADING AND UTILITY PLAN 05.22.2013C3.0 FOUNDATION DRAINAGE PLAN 05.22.2013
VICINITY MAP
TRIAD 12TH AVENUE
PROJECT INFORMATIONADDRESS: 4123, 4119 12TH AVE NE; SEATTLE, WA 98105
LEGAL DESCRIPTION: SEE SHEET A1.00 FOR LEGAL DESCRIPTIONS
PARCEL NO: 114200-1675; 114200-1670
SITE AREA: 8,240 SF
PROJECT DESCRIPTION7-STORY STRUCTURE WITH BASEMENT - 102 RESIDENTIAL DWELLING UNITS.2 EXISTING HOMES TO BE DEMOLISHED.
ZONING CODE DATA*SEE SHEET A0.2 FOR ZONING CODE ANALYSIS AND DIAGRAMSZONING CODE: SEATTLE LAND USE & ZONING CODEZONE: MROVERLAYS: NONEURBAN VILLAGE: UNIVERSITY DISTRICT NORTHWEST URBAN CENTER VILLAGEECA: NONE
BUILDING CODE DATABUILDING CODE: 2009 INTERNATIONAL BUILDING CODE WITH SEATTLE AMENDMENTS
ICC/ANSI A117.1-2003: Accessible and Usable Buildings And Facilities
PROPOSED USE: 102 APARTMENT UNITS (RESIDENTIAL)
CONSTRUCTION TYPE: 5 STORIES TYPE VA OVER 2 STORIES TYPE 1A OVER1 BASEMENT TYPE 1A
OCCUPANCY GROUP: R-2: RESIDENTIALB: BUSINESS
BUILDING HEIGHT: 7 STORIES + 1 BASEMENT
PERMIT & REVIEW NUMBERSMASTER USE PERMIT:BUILDING PERMIT:
REVIEW #30130266306055
SUBMITTAL05.03.201211.08.2012
PERMIT--
PROJECT TEAM
PROJECT SITE
LEVEL RESIDENTIALLEVEL B1 2144 SFLEVEL 1 3396 SFLEVEL 2 4368 SFLEVEL 3 4368 SFLEVEL 4 4368 SFLEVEL 5 4368 SFLEVEL 6 4368 SFLEVEL 7 4368 SFROOF DECK 0 SF
31748 SF
UNIT MATRIX RESIDENTIAL CORE964 SF850 SF884 SF884 SF884 SF884 SF884 SF884 SF277 SF7395 SF
LEASING/LOBBY0 SF
687 SF0 SF0 SF0 SF0 SF0 SF0 SF0 SF
687 SF
TENANT STORAGE293 SF0 SF0 SF0 SF0 SF0 SF0 SF0 SF0 SF
293 SF
BIKE PARKING721 SF0 SF0 SF0 SF0 SF0 SF0 SF0 SF0 SF
721 SF
UTILITY927 SF431 SF0 SF0 SF0 SF0 SF0 SF0 SF
191 SF1548 SF
GROSS FLOOR AREA MATRIX*THIS TABLE IS FOR THE OWNER'S BENEFIT AND IS NOT RELEVANT TOZONING OR BUILDING CODE ANALYSIS.
TOTAL5361 SF5364 SF5252 SF5252 SF5252 SF5252 SF5252 SF5252 SF468 SF
42705 SFTOTAL
STRUCTURAL SHEET INDEX
S1.0 STRUCTURAL GENERAL NOTES 05.22.2013S1.1 STRUCTURAL GENERAL NOTES 05.22.2013S1.2 STRUCTURAL GENERAL NOTES 05.22.2013S1.3 STRUCTURAL GENERAL NOTES, DRAWING LEGEND
AND ABBREVIATIONS05.22.2013
S2.0 B1 FOUNDATION/ FRAMING PLAN 05.22.2013S2.1 LEVEL 1 MILD REINFORCING PLAN 05.22.2013S2.1A LEVEL 1 POST-TENSIONED FRAMING PLAN 05.22.2013S2.2 LEVEL 2 MILD REINFORCING PLAN 05.22.2013S2.2A LEVEL 2 POST-TENSIONED FRAMING PLAN 05.22.2013S2.3 LEVEL 3 MILD REINFORCING PLAN 05.22.2013S2.3A LEVEL 3 POST-TENSIONED FRAMING PLAN 05.22.2013S2.3B LEVEL 2 STUD AND SHEAR WALL PLAN 05.22.2013S2.4 LEVEL 4-7 FRAMING PLAN 05.22.2013S2.4A LEVELS 4-7 STUD AND SHEAR WALL PLAN 05.22.2013S2.5A LEVEL 5 STUD AND SHEAR WALL PLAN 05.22.2013S2.6A LEVEL 6 STUD AND SHEAR WALL PLAN 05.22.2013S2.7A LEVEL 7 STUD AND SHEAR WALL PLAN 05.22.2013S2.8 ROOF FRAMING PLAN 05.22.2013S2.9 HIGH ROOF FRAMING PLAN 05.22.2013S3.0 STRUCTURAL FOUNDATION DETAILS 05.22.2013S3.1 STRUCTURAL CONCRETE DETAILS 05.22.2013S3.11 CONCRETE SHEAR WALL ELEVATIONS 05.22.2013S3.12 CONCRETE SHEAR WALL BOUNDARY
REINFORCING05.22.2013
S4.0 STRUCTURAL CONCRETE COLUMN DETAILS 05.22.2013S4.1 STRUCTURAL CONCRETE FRAMING DETAILS 05.22.2013S5.0 STRUCTURAL POST-TENSIONED DETAILS 05.22.2013S5.1 STRUCTURAL STUDRAIL DETAILS 05.22.2013S6.0 STRUCTURAL WOOD FRAMING DETAILS 05.22.2013S6.1 STRUCTURAL WOOD FRAMING DETAILS 05.22.2013S6.2 STRUCTURAL WOOD FRAMING DETAILS 05.22.2013S6.3 STRUCTURAL STAIR FRAMING DETAILS 05.22.2013
SHORING SHEET INDEX
SS1.0 SHORING NOTES AND DETAILS 05.22.2013SS2.0 SHORING PLAN 05.22.2013SS3.0 SHORING ELEVATIONS 05.22.2013
BUILDING ENVELOPE SHEET INDEX
BE0.00 NOTES AND INDEX 05.22.2013BE0.10 AIR BARRIER DIAGRAMS 05.22.2013BE1.00 BELOW GRADEAND COURTYARD DETAILS 05.22.2013BE1.10 BELOW GRADE AND COURTYARD DETAILS 05.22.2013BE2.00 CLADDING DETAILS 05.22.2013BE2.10 CLADDING DETAILS 05.22.2013BE3.00 WINDOW INSTALLATION AT TYPE 1A 05.22.2013BE3.05 WINDOW INSTALLATION AT TYPE VA 05.22.2013BE3.10 WINDOW AND DOOR DETAILS 05.22.2013BE3.20 WINDOW AND DOOR DETAILS 05.22.2013BE4.00 ARCHITECTURAL FRAME DETAILS 05.22.2013BE5.00 ROOF DETAILS 05.22.2013
LEVEL B1 7LEVEL 1 11LEVEL 2 14LEVEL 3 14LEVEL 4 14LEVEL 5 14LEVEL 6 14LEVEL 7 14TOTAL: 102
LEVEL STUDIO5049 SF
42393 SF
1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.135 BP CORRECTION 3 05.09.13
MECHANICAL SHEET INDEX
M0.1 SYMBOLDS, LEGEND, ABBREVIATIONS & NOTES 05.22.2013M0.2 SCHEDULES 05.22.2013M2.0 BASEMENT PLAN HVAC 05.22.2013M2.1 LEVEL 1 PLAN HVAC 05.22.2013M2.2 LEVEL 2 PLAN HVAC 05.22.2013M2.3 LEVEL 3-7 PLAN HVAC 05.22.2013M2.4 ROOF PLAN HVAC 05.22.2013M3.0 DETAILS 05.22.2013
ELECTRICAL SHEET INDEX
E0.1 SYMBOL SCHEDULE 05.22.2013E1.0 SITE PLAN 05.22.2013E2.0 LEVEL B1 PLAN 05.22.2013E2.1 LEVEL 1 PLAN 05.22.2013E2.2 LEVEL 2 PLAN 05.22.2013E2.3 LEVELS 3-7 PLAN 05.22.2013E2.4 ROOF PLAN 05.22.2013E3.0 TYPICAL UNIT PLANS 05.22.2013E4.0 POWER RISER 05.22.2013E4.1 PANEL SCHEDULES 05.22.2013
PLUMBING SHEET INDEX
P0.1 SYMBOLS, LEGEND, ABBREVIATIONS, NOTES & CALCS 05.22.2013P0.2 SCHEDULES 05.22.2013P1.0 UNDER GROUND PLAN PLUMBING 05.22.2013P2.0 BASEMENT PLAN PLUMBING 05.22.2013P2.1 LEVEL 1 PLAN PLUMBING 05.22.2013P2.2 LEVEL 2 PLAN PLUMBING 05.22.2013P2.3 LEVEL 3-7 PLAN PLUMBING 05.22.2013P2.4 ROOF PLAN PLUMBING 05.22.2013P3.0 DETAILS 05.22.2013P4.0 RISER DIAGRAMS 05.22.2013P4.1 RISER DIAGRAMS & UNIT PLANS 05.22.2013
INTERIOR DESIGN SHEET INDEX
ID1.0 INTERIOR FINISH LEGEND 05.22.2013ID1.1 INTERIOR FINISH SCHEDULE 05.22.2013ID2.0 FINISH PLAN - LEVEL B1 05.22.2013ID2.1 FINISH PLAN - FIRST FLOOR 05.22.2013ID2.2 FINISH PLAN - SECOND FLOOR 05.22.2013ID2.3 FINISH PLAN - FLOORS 3-7 05.22.2013ID2.4 FINISH PLAN - ROOF 05.22.2013ID3.0 RCP LEVEL B1 05.22.2013ID3.1 RCP FIRST FLOOR 05.22.2013ID3.2 RCP SECOND FLOOR 05.22.2013ID3.3 RCP FLOORS 3-7 05.22.2013ID3.4 RCP ROOF 05.22.2013ID3.5 ENLARGED RCP FIRST FLOOR 05.22.2013ID4.1 INTERIOR ELEVATIONS 05.22.2013
1. THE DRAWINGS ARE INTENDED TO ONLY PARTIALLY DESCRIBE THE SCOPE OF WORKFOR THE PROJECT. ANY WORK NOT SHOWN HERE, BUT REQUIRED BY CODE, OR THESPECIFICATIONS, OR TO MAKE THE WORK COMPLETE, SHALL BE PROVIDED AS PART OF THEWORK.
2. REFER TO THE LIST OF ABBREVIATIONS FOR COMMON ABBREVIATIONS USED IN THEDRAWINGS. IF AN ABBREVIATION IS NOT ON THE LIST, OR NOT COMMONLY USED, REFER TOTHE ARCHITECT FOR CLARIFICATION.
3. IT IS THE INTENT OF THE DOCUMENTS THAT ALL WORK COMPLIES WITH THE SEATTLEBUILDING CODE, SEATTLE MECHANICAL CODE, SEATTLE ELECTRICAL CODE, SEATTLEENERGY CODE, SEATTLE FIRE CODE, SEATTLE LAND USE AND ZONING CODE, WASHINGTONSTATE VENTILATION AND INDOOR AIR QUALITY CODE, AND ALL APPLICABLE LOCAL, STATE,AND NATIONAL CODES AND ORDINANCES IN EFFECT AT THE DATE OF PERMIT SUBMITTAL.NOTHING IN THESE DRAWINGS SHALL BE CONSTRUED TO GRANT APPROVAL FOR ANY CODEVIOLATION. ANY ERRORS, OMISSIONS, OR NON-COMPLIANCE WITH GOVERNING CODES SHALLBE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
4. BEFORE STARTING EACH PORTION OF THE WORK, THE CONTRACTOR SHALL CAREFULLYSTUDY AND COMPARE THE VARIOUS DRAWINGS AND OTHER CONTRACT DOCUMENTSRELATED TO THAT PORTION OF THE WORK, AS WELL AS OWNER-PROVIDED INFORMATION,SHALL TAKE FIELD MEASUREMENTS OF ANY EXISTING CONDITIONS RELATED TO THATPORTION OF THE WORK AND SHALL OBSERVE ANY CONDITIONS AT THE SITE AFFECTING IT.ANY ERRORS, INCONSISTENCIES OR OMISSIONS SHALL BE REPORTED PROMPTLY TO THEARCHITECT.
5. DO NOT SCALE THE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ONTHE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. IF DISCREPANCIES ARE FOUND, THEARCHITECT SHALL BE NOTIFIED AT ONCE.
6. DIMENSIONS ARE SHOWN TO THE FACE OF CONCRETE, FACE OF SHEATHING ATEXTERIOR WOOD WALLS (FACE OF RIGID INSULATION AT EXTERIOR METAL WALLS), FACE OFSTUD AT INTERIOR WALLS, CENTER OF UNIT DEMISING WALLS, WINDOW CENTERLINES, ANDEDGE OF OPENINGS, UNLESS DETAILED OR NOTED OTHERWISE ON DRAWINGS. REFER TOTHE ARCHITECT IF CLARIFICATION IS NEEDED.
7. REPETITIVE FEATURES NOT INDICATED IN THE DRAWINGS EVERYWHERE THEY OCCURSHALL BE PROVIDED AS IF DRAWN IN FULL.
8. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONESHALL BE AS BINDING AS IF REQUIRED BY ALL. IN CASE OF DISCREPANCY, REFER TO THEARCHITECT FOR CLARIFICATION.
9. THE CONTRACTOR SHALL VERIFY THE DIMENSIONS REQUIRED FOR ALL EQUIPMENT,APPLIANCES, FIXTURES, CABINETS, DUCTWORK, AND OPENINGS BEFORE FRAMING BEGINS.THE CONTRACTOR SHALL COORDINATE WITH THE SUBCONTRACTORS OF ALL TRADES TOVERIFY THE SIZES AND LOCATIONS OF OPENINGS THROUGH THE FLOORS, WALLS, CEILINGSAND ROOFS FOR DUCTS, PIPES, CONDUITS, AND EQUIPMENT. THE CONTRACTOR SHALLCOORDINATE THE LOCATION AND INSTALLATION OF WOOD BACKING, BLOCKING, FURRINGAND STRIPPING AS REQUIRED FOR THE INSTALLATION AND ATTACHMENT OF WORK OF ALLTRADES.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SYSTEMS, INCLUDING, BUT NOTLIMITED TO, MECHANICAL, PLUMBING, AND ELECTRICAL WORK. WORK SHOWN ON THEDRAWINGS IS INTENDED TO ILLUSTRATE THE GENERAL DESIGN INTENT, SCOPE, ANDLOCATION OF WORK. ALL WORK NOT SPECIFICALLY DRAWN, BUT REQUIRED FOR ACOMPLETE, LEGAL, AND FUNCTIONING SYSTEM, SHALL BE PROVIDED AS PART OF THE WORK.
11. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND GOVERNMENTALFEES, LICENSES AND INSPECTIONS NECESSARY FOR PROPER EXECUTION AND COMPLETIONOF THE WORK, WITH THE EXCEPTION OF THE MASTER USE PERMIT AND THE BUILDINGPERMIT.
12. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION OR SITE DEVELOPMENTACTIVITY, THE CONTRACTOR SHALL SCHEDULE PRE-CONSTRUCTION MEETINGS WITH THECITY OF SEATTLE DPD, SEATTLE CITY LIGHT, AND SEATTLE DEPARTMENT OFTRANSPORTATION.
13. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION OR SITE DEVELOPMENTACTIVITY, THE CONTRACTOR AND/OR ARCHITECT SHALL SCHEDULE A PRE-CONSTRUCTIONMEETING WITH THE PROJECT TEAM MEMBERS FOR THE PURPOSE OF ANSWERING INITIALQUESTIONS, CLARIFYING AREAS OF CONCERN, AND FORMALIZING A CONSTRUCTIONADMINISTRATION PROCESS. THE MEETING(S) SHALL INCLUDE THE ARCHITECT, GENERALCONTRACTOR, OWNER, LANDSCAPE ARCHITECT, STRUCTURAL ENGINEER, CIVIL ENGINEER,GEOTECHNICAL ENGINEER, AND WATER INTRUSION CONSULTANT.
GENERAL REQUIREMENTS
SITE NOTES1. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING SITE CONDITIONS,DISTANCES, AND TOPOGRAPHIC CONTOURS. SITE CONDITIONS SHOWN ARE FROM OWNER-PROVIDED INFORMATION, SURVEYS BY OTHERS, AND PUBLIC RECORDS. THE ARCHITECT ISNOT RESPONSIBLE FOR THE ACCURACY OF THE SURVEY OR EXISTING SITE INFORMATION.
2. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL UTILITIES BEFORE BEGINNINGCONSTRUCTION BY RETAINING A UTILITY LOCATION SERVICE AND MARKING ALLUNDERGROUND UTILITY LOCATIONS. ANY UTILITY LOCATIONS SHOWN ON THE DRAWINGSARE BASED ON AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE ONLY. UTILITIESMAY BE PRESENT BUT NOT SHOWN ON THE DRAWINGS. CARE SHOULD BE TAKEN TO AVOIDDAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL COORDINATE CONNECTIONLOCATIONS AND ELEVATIONS WITH THE UTILITY COMPANIES. RELOCATION OF UTILITIES, IFNECESSARY, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
3. THE CONTRACTOR SHALL EXECUTE AND COMPLETE ALL WORK ON ADJACENTPROPERTIES AND PUBLIC RIGHTS-OF-WAY THAT IS REQUIRED BY CONSTRUCTIONEASEMENT AGREEMENTS WITH NEIGHBORING PROPERTY OWNERS, PRIVATE CONTRACTDOCUMENTS WITH THE SEATTLE DEPARTMENT OF TRANSPORTATION, STREET USEPERMITS, OR ANY OTHER AGREEMENT OR CONTRACT. ALL IMPROVEMENTS AND REPAIRSTO SIDEWALKS, ALLEYS, STREETS AND NEIGHBORING PROPERTIES SHALL BECOORDINATED TO MINIMIZE THE IMPACT ON THE PUBLIC AND TO MAINTAIN ACCESS TONEIGHBORING PROPERTIES. THE CONTRACTOR SHALL MAKE ARRANGEMENTS AND SECURENECESSARY PERMITS WHEN CONSTRUCTION REQUIRES STREET OR SIDEWALK CLOSURES.
4. IF ANY HAZARDOUS MATERIAL, INCLUDING BUT NOT LIMITED TO ASBESTOS ORPOLYCHLORINATED BIPHENYL (PCB), IS ENCOUNTERED ON THE SITE BY THE CONTRACTOR,THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER.
5. PRIOR TO BEGINNING ANY DEMOLITION WORK, THE OWNER OR CONTRACTOR SHALLSUBMIT A “NOTICE OF INTENT” TO THE PUGET SOUND CLEAN AIR AGENCY (PSCAA) ANDFULFILL THEIR REQUIREMENTS.
6. NEW WATER MAINS, FIRE HYDRANTS, AND TEMPORARY FIRE DEPARTMENT ACCESSSHALL BE INSTALLED, INSPECTED, AND APPROVED BY THE FIRE DEPARTMENT PRIOR TOTHE COMMENCEMENT OF COMBUSTIBLE CONSTRUCTION.
INTERIOR ENVIRONMENT NOTES1. OCCUPIABLE SPACES, HABITABLE SPACES, AND CORRIDORS SHALL HAVE A CEILINGHEIGHT OF NOT LESS THAN 7'-6". BATHROOMS, TOILET ROOMS, KITCHENS, STORAGEROOMS AND LAUNDRY ROOMS SHALL BE PERMITTED TO HAVE A CEILING HEIGHT OF NOTLESS THAN 7'-0" PER SBC 1208.2.
2. PROVIDE AN ATTIC ACCESS OPENING AT ALL ATTIC SPACES AT LEAST 30" HIGH. THEACCESS OPENING SHALL BE A MINIMUM OF 20" X 30" WITH AT LEAST 30" OF HEADROOM ATOR ABOVE THE OPENING. SBC 1209.2.
3. PROVIDE AN 18" X 24" MINIMUM ACCESS OPENING AT ALL CRAWL SPACES. SBC 1209.1.
4. PUBLIC RESTROOM FLOORS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACEEXTENDING UPWARD ONTO THE WALLS AT LEAST 4 INCHES PER SBC 1210.1. WALLS WITHIN2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENTSURFACE TO A HEIGHT OF AT LEAST 4 FEET ABOVE THE FLOOR PER SBC 1210.2.
5. ACCESSORIES SUCH AS GRAB BARS, TOWEL BARS, PAPER DISPENSERS AND SOAPDISHES, PROVIDED ON OR WITHIN WALLS, SHALL BE INSTALLED AND SEALED TO PROTECTSTRUCTURAL ELEMENTS FROM MOISTURE. SBC 1210.2.
INTERIOR ENVIRONMENT NOTES (CONT)6. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLEDSHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO AHEIGHT OF NOT LESS THAN 70 INCHES ABOVE THE DRAIN INLET. BUILT-IN TUBS WITHSHOWERS SHALL HAVE WATERPROOF JOINTS BETWEEN THE TUB AND ADJACENTWALL. SBC 1210.3, 1210.4.
7. AS A FORMALDEHYDE REDUCTION MEASURE, ALL STRUCTURAL COMPONENTSSUCH AS SOFT PLYWOOD, PARTICLE BOARD, WAFER BOARD AND OSB SHALL BEIDENTIFIED AS “EXPOSURE 1”, “EXTERIOR”, OR “HUD-APPROVED”.
8. INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCEWITH ASTM E 84 WITH A MINIMUM OF CLASS C THROUGHOUT. CLASS C HAS A FLAMESPREAD INDEX OF 76-200 AND SMOKE-DEVELOPED INDEX OF 0-450. SBC 803.1.
ACCESSIBILITY NOTES1. ACCESSIBLE ROUTES SHALL BE PROVIDED FROM ACCESSIBLE PARKING,PASSENGER LOADING ZONES AND PUBLIC STREETS OR SIDEWALKS TO THE ACCESSIBLEBUILDING ENTRANCE. AN ACCESSIBLE ROUTE SHALL BE PROVIDED TO EACH ACCESSIBLEPORTION OF THE BUILDING AND SHALL CONNECT EACH ACCESSIBLE LEVEL. SBC 1104.
2. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGENTRANCES WITH THE PRIMARY ENTRANCE OF EACH DWELLING UNIT AND WITH THEEXTERIOR AND INTERIOR SPACES THAT SERVE THE UNITS. SBC 1107.4.
3. CONTROLS, OPERATING MECHANISMS AND HARDWARE INTENDED FOR OPERATIONBY THE OCCUPANT, LOCATED IN ACCESSIBLE SPACES OR ALONG ACCESSIBLE ROUTESSHALL BE ACCESSIBLE. SBC 1109.12.
4. INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACESSHALL BE TACTILE.
5. DIRECTIONAL AND INFORMATIONAL SIGNS OTHER THAN BUILDING DIRECTORIES SHALLCONTAIN VISUAL CHARACTERISTICS COMPLYING WITH ICC A117.1. SBC 1110.
6. REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THE INTERNATIONALSYMBOL OF ACCESSIBILITY PER SBC 1110.1. THESE AREAS INCLUDE, BUT ARE NOTLIMITED TO, ACCESSIBLE PARKING SPACES (IF > 4), ACCESSIBLE AREAS OF REFUGE,ACCESSIBLE ENTRANCES WHERE ALL ENTRANCES ARE NOT ACCESSIBLE, AND UNISEXTOILETS AND BATHING ROOMS.
7. INTERIOR AREAS OF REFUGE AND EXTERIOR AREAS OF ASSISTED RESCUE SHALL BEPROVIDED WITH TW0-WAY COMMUNICATION SYSTEM TO A CENTRAL CONTROL POINT. IFCONTROL POINT NOT CONSTANTLY ATTENDED, AREA OF REFUGE SHALL ALSO HAVECONTROLLED ACCESS TO A PUBLIC TELEPHONE SYSTEM.
8. TWO-WAY COMMUNICATION SYSTEM SHALL HAVE BOTH AUDIBLE AND VISUALSIGNALS AND INSTRUCTIONS POSTED ADJACENT TO THE SYSTEM CONTROLS.iNSTRUCTIONS SHALL INSTRUCT HOW TO USE TW0-WAY COMMUNICATION SYSTEM,DIRECT USERS TO OTHER MEANS OF EGRESS, INFORM USERS HOW TO SUMMONASSISTANCE, AND STATE THAT PERSONS ABLE TO USE STAIRS SHOULD DO SO ASAP,UNLESS ASSISTING OTHERS.
9. REQUIREMENTS FOR DWELLING UNITS:a. THE ACCESSIBLE PRIMARY ENTRANCE SHALL BE ON AN ACCESSIBLE ROUTE FROMPUBLIC AND COMMON AREAS. WITHIN THE UNIT, AT LEAST ONE ACCESSIBLE ROUTESHALL CONNECT ALL SPACES AND ELEMENTS. THE ACCESSIBLE ROUTE SHALL HAVE ACLEAR WIDTH OF AT LEAST 36 INCHES, EXCEPT THAT SEGMENTS LESS THAN 24 INCHESIN LENGTH MAY HAVE A CLEAR WIDTH OF 32 INCHES.
b. IN TYPE A UNITS, TURNING SPACES SHALL BE REQUIRED IN ALL ROOMS, WITH THEEXCEPTION OF BATHROOMS IN A UNIT THAT ALREADY HAS AT LEAST ONE BATHROOMMEETING ALL THE REQUIREMENTS OF ANSI 1003.11. TURNING SPACE SHALL BE EITHER ACIRCULAR OR T-SHAPED SPACE. CIRCULAR SPACE SHALL BE 60" IN DIAMETER. T-SHAPEDSPACE SHALL FIT WITHIN A 60" X 60" SQUARE, WITH THE WIDTH OF EACH ARM AND BASE36" MINIMUM.
c. THE CORRIDOR SIDE OF ALL PRIMARY ENTRANCE DOORS TO ALL UNITS SHALL HAVEMANEUVERING CLEARANCE COMPLYING WITH ANSI 404, ICC A117.1.
d. IN TYPE A UNITS, ALL DOORWAYS INTENDED FOR PASSAGE SHALL HAVEMANEUVERING CLEARANCES COMPLYING WITH ANSI 404, ICC A117.1. BATHROOMS IN AUNIT THAT ALREADY HAS AT LEAST ONE BATHROOM MEETING ALL THE REQUIREMENTSOF ANSI 1003.11 DO NOT HAVE TO COMPLY WITH THE MANEUVERING CLEARANCES ONTHE BATHROOM SIDE OF THE DOOR.
e. CHANGES IN LEVEL OF 1/4" OR LESS ARE PERMITTED TO BE VERTICAL. CHANGES INLEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE OF 1:2. THRESHOLDSSHALL NOT BE GREATER THAN 1/2" EXCEPT THAT THEY MAY BE 3/4" AT EXTERIOR SLIDINGDOORS.
f. IN TYPE A UNITS, LIGHTING CONTROLS, ELECTRICAL SWITCHES AND RECEPTACLEOUTLETS, ENVIRONMENTAL CONTROLS, APPLIANCE CONTROLS, OPERATING HARDWAREFOR OPERABLE WINDOWS, PLUMBING FIXTURE CONTROLS, AND USER CONTROLS FORSECURITY OR INTERCOM SYSTEMS SHALL BE PROVIDED WITH A CLEAR FLOOR SPACEAND BE PLACED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 308, ICCA117.1. THEY SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHTGRASPING, PINCHING, OR TWISTING OF THE WRIST. THE MAXIMUM FORCE REQUIRED TOACTIVATE THE PARTS SHALL BE 5 POUNDS.
g. IN TYPE B UNITS, LIGHTING CONTROLS, ELECTRICAL SWITCHES AND RECEPTACLEOUTLETS, ENVIRONMENTAL CONTROLS, AND USER CONTROLS FOR SECURITY ORINTERCOM SYSTEMS SHALL BE PROVIDED WITH A CLEAR FLOOR SPACE AND BE PLACEDWITHIN ONE OF THE REACH RANGES SPECIFIED IN ANSI 308, ICC A117.1.
h. "CLEAR FLOOR SPACE" IS 30"X48" PER ANSI 305.3.
i. OPERABLE PARTS SHALL BE PLACED BETWEEN 15" AND 48" ABOVE THE FLOOR IN ANAREA WITH UNOBSTRUCTED FORWARD OR SIDE REACH. WHEN THERE IS ANOBSTRUCTION OF 24" MAX WIDTH AND 34" MAX HEIGHT, THE OPERABLE PARTS SHALL BENO HIGHER THAN 46" ABOVE THE FLOOR. WHEN THERE IS AN OBSTRUCTION OF 25” MAXWIDTH IN A SPACE ALLOWING A FORWARD APPROACH, THE OPERABLE PARTS SHALL BENO HIGHER THAN 44” ABOVE THE FLOOR.ANSI 308, ICC A117.1.
j. BATHROOMS REQUIRE CLEAR FLOOR SPACES, CLEARANCES AROUND, BETWEEN,AND ADJACENT TO FIXTURES, REINFORCING FOR GRAB BARS, AND OTHER ITEMSSHOWN IN THE DRAWINGS. THE CONTRACTOR OR OWNER SHALL NOT MAKEDIMENSIONAL CHANGES TO ANY BATHROOM WITHOUT THE APPROVAL OF THEARCHITECT.
k. BATHTUB ENCLOSURES SHALL NOT HAVE TRACKS INSTALLED ON THE RIM OF THEBATHTUB.
l. KITCHENS REQUIRE CLEAR FLOOR SPACES, CLEARANCES AROUND, BETWEEN, ANDADJACENT TO FIXTURES, APPLIANCES, CABINETS, COUNTERS AND WALLS, AND OTHERITEMS SHOWN IN THE DRAWINGS. THE CONTRACTOR OR OWNER SHALL NOT MAKEDIMENSIONAL CHANGES TO ANY KITCHEN WITHOUT THE APPROVAL OF THE ARCHITECT.
m. IN TYPE A UNITS, WASHING MACHINES AND CLOTHES DRYERS REQUIRE A CLEARFLOOR SPACE, POSITIONED FOR PARALLEL APPROACH, CENTERED ON EACHAPPLIANCE. ALL OPERABLE PARTS SHALL COMPLY WITH SECTION 309, ICC A117.1,INCLUDING THE REACH RANGES SPECIFIED IN ANSI 308, ICC A117.1. TOP LOADINGMACHINES SHALL HAVE THE DOOR TO THE LAUNDRY COMPARTMENT 36" MAX ABOVE THEFLOOR. FRONT LOADING MACHINES SHALL HAVE THE BOTTOM OF THE OPENING TO THELAUNDRY COMPARTMENT BETWEEN 15" AND 34" ABOVE THE FLOOR.
n. IN TYPE B UNITS, WASHING MACHINES AND CLOTHES DRYERS REQUIRE A CLEARFLOOR SPACE, POSITIONED FOR PARALLEL APPROACH, CENTERED ON EACHAPPLIANCE. IF NECESSARY FOR GREATER ACCESSIBILITY, THE CLOSET DOORS MAY BEREMOVED AND THE APPLIANCES MOVED FORWARD TO FLUSH OUT WITH THE ADJACENTWALLS.
o. PROVIDE BLOCKING IN ALL TYPE A & B UNITS AS INDICATED IN PLANS AND DETAILS.
EGRESS NOTES1. THE WIDTH OF STAIRWAYS SHALL NOT BE LESS THAN 44 INCHES. SBC 1009.1.
2. STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCE OF 80 INCHESMEASURED VERTICALLY FROM A LINE CONNECTING THE EDGE OF THE NOSINGS. SBC1009.2.
3. STAIR RISER HEIGHTS SHALL BE 7 INCHES MAXIMUM AND 4 INCHES MINIMUM. STAIRTREAD DEPTHS SHALL BE 11 INCHES MINIMUM. SBC 1009.4.2.
4. STAIR TREADS AND RISERS SHALL BE OF UNIFORM SIZE AND SHAPE. THE TOLERANCEBETWEEN THE LARGEST AND SMALLEST RISER OR BETWEEN THE LARGEST ANDSMALLEST TREAD SHALL NOT EXCEED 0.375 INCH IN ANY FLIGHT OF STAIRS. SBC 1009.4.4.
5. STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE. HANDRAILS SHALL BE OF AUNIFORM HEIGHT, BETWEEN 34" AND 38" ABOVE THE STAIR-TREAD NOSING PER SBC1012.2. HANDRAILS SHALL BE CONTINUOUS PER SBC 1012.4.
6. HANDRAILS ARE TO BE GRASPABLE, WITH A DIAMETER BETWEEN 1 1/4 INCHES AND 2INCHES OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THE HANDRAIL IS NOTCIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION BETWEEN 4 INCHES AND 6 1/4INCHES WITH A MAX. CROSS-SECTION DIMENSION OF 2 1/4 INCHES AND A MIN. EDGERADIUS OF 0.01 INCH. SBC 1012.3.
7. HANDRAILS SHALL BE CONTINUOUS BETWEEN FLIGHTS, OR THEY SHALL RETURN TOA WALL OR THE WALKING SURFACE. AT THE TOP OF A STAIRWAY, HANDRAILS MUSTEXTEND HORIZONTALLY 12 INCHES BEYOND THE TOP RISER. AT THE BOTTOM OF THESTAIRWAY, HANDRAILS MUST CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREADBEYOND THE BOTTOM RISER. EXTENSIONS NOT REQUIRED ON STAIRWAYS THAT ARENOT PART OF A REQUIRED MEANS OF EGRESS. SBC 1012.6.
8. GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES THAT AREMORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW AND AS SHOWN IN THEDRAWINGS. SBC 1013.1.
9. HANDRAIL ASSEMBLIES AND GUARDS SHALL BE DESIGNED AND CONSTRUCTED TOTHE STRUCTURAL LOADING CONDITIONS SET FORTH IN SBC 1607.7.
10. GUARDS SHALL FORM A PROTECTIVE BARRIER NO LESS THAN 42" HIGH. SBC 1013.2.
11. OPEN GUARDS SHALL BE DESIGNED AND CONSTRUCTED SO THAT A 4" DIAMETERSPHERE CANNOT PASS THROUGH ANY OPENING UP TO A HEIGHT OF 34". FROM 34" TO 42",AN 8" DIAMETER SPHERE SHALL NOT PASS. SBC 1013.3.
12. INTERIOR VERTICAL EXIT ENCLOSURES CONNECTING MORE THAN 3 STORIES SHALLHAVE STAIRWAY SIGNAGE AT EACH FLOOR LANDING. THE SIGN SHALL BE LOCATED 5FEET ABOVE THE FLOOR LANDING AND BE READILY VISIBLE WHEN THE DOORS ARE INBOTH OPEN AND CLOSED POSITIONS. SBC 1022.8.
13. STAIRWAY SIGNS SHALL DESIGNATE THE FLOOR LEVEL, THE TERMINUS OF THE TOPAND BOTTOM OF THE STAIR ENCLOSURE, THE IDENTIFICATION OF THE STAIR, THE STORYAND DIRECTION TO THE EXIT DISCHARGE, WHETHER THERE IS ROOF ACCESS FOR FIREDEPARTMENT, AND WHETHER THE ROOF IS ACCESSED BY ROOF HATCH.
14. EXIT SIGNS ARE REQUIRED AT EACH EXIT, EXIT ACCESS DOOR, AND ALONG THEACCESS TO THE EXIT. NO POINT IN AN EXIT ACCESS CORRIDOR SHALL BE MORE THAN 100FEET FROM THE NEAREST VISIBLE EXIT SIGN. EXIT SIGNS SHALL BE VISIBLE FROM ANYDIRECTION OF EGRESS TRAVEL, AND SHALL BE ILLUMINATED AT ALL TIMES. SBC 1011.1
15. TACTILE EXIT SIGNS SHALL BE PROVIDED ADJACENT TO AREAS OF REFUGE, ANEXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY, AN EXIT RAMP, AN EXITPASSAGEWAY AND THE EXIT DISCHARGE, COMPLYING TO ICC A117.1 PER SBC 1011.3.
16. PLACARDS READING "NOT AN EXIT" SHALL BE INSTALLED AT ALL DOORWAYS,PASSAGEWAYS OR STAIRWAYS WHICH ARE NOT EXITS, EXIT ACCESSES OR EXITDISCHARGES AND WHICH MAY BE MISTAKEN FOR AN EXIT PER SBC 1011.6. REFER TOPLANS FOR EXIT SIGN LOCATIONS.
17. THE MEANS OF EGRESS SHALL BE ILLUMINATED AT ALL TIMES AND AT EVERY POINT INTHE MEANS OF EGRESS. REFER TO LIGHTING NOTES FOR SPECIFIC REQUIREMENTS.
18. PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT ENCLOSURE AREPROHIBITED EXCEPT FOR REQUIRED EXIT DOORS AND MECHANICAL SYSTEMS SERVINGTHE EXIT ENCLOSURE. PENETRATIONS MUST BE PROTECTED ACCORDING TO SECTION715. SBC 1022.3 & 1022.4.
19. EQUIPMENT IS PROHIBITED IN EXIT ENCLOSURES EXCEPT FOR EQUIPMENTNECESSARY FOR INDEPENDENT PRESSURIZATION, LIGHTING OF THE EXIT ENCLOSURE,SPRINKLER PIPING, STANDPIPES, ELECTRICAL EQUIPMENT FOR FIRE DEPARTMENTCOMMUNICATION AND SPRINKLER MONITORING, AND UNIT HEATERS REQUIRED TOPROTECT FIRE PROTECTION EQUIPMENT FROM FREEZING. SBC 1022.10.
FIRE-RESISTANCE RATED CONS'T NOTES1. THROUGH PENETRATIONS IN FIRE-RESISTANCE-RATED WALLS SHALL BE PROTECTED.THEY SHALL BE INSTALLED AS TESTED IN AN APPROVED FIRE-RESISTANCE-RATED ASSEMBLYOR PROTECTED WITH AN APPROVED PENETRATION FIRESTOP SYSTEM. SBC 713.3.1.
2. LISTED ELECTRICAL BOXES MAY BE INSTALLED IN FIRE-RESISTANCE-RATED WALLSPROVIDED THEY HAVE BEEN TESTED AND ARE INSTALLED IN ACCORDANCE WITH THEINSTRUCTIONS INCLUDED IN THE LISTING. OUTLETS ON OPPOSITES SIDE OF THE WALLSHALL BE SEPARATED BY THE HORIZONTAL DISTANCE SPECIFIED IN THE LISTING, SOLIDFIREBLOCKING, LISTED PUTTY PADS, OR OTHER LISTED MATERIALS AND METHODS. SBC712.3.2.
3. PENETRATIONS OF A FLOOR, FLOOR/CEILING ASSEMBLY OR THE CEILING MEMBRANE OFA ROOF/CEILING MEMBRANE SHALL BE ENCLOSED BY SHAFTS IN ACCORDANCE WITHSECTION 707 OR PROTECTED IN ACCORDANCE WITH SBC SECTIONS 712.4 AND 713.
4. CAN LIGHTS IN FIRE-RESISTANCE-RATED HORIZONTAL ASSEMBLIES SHALL BE BOXED ONFOUR SIDES AND TOP WITH 5/8" GYPSUM WALLBOARD. HVAC FANS OR DIFFUSERS SHALL BEBOXED ON FOUR SIDES AND TOP WITH 5/8" GYPSUM WALLBOARD. DUCTS SHALL BEWRAPPED W/1 1/2" HIGH-DENSITY MINERAL FIBER OR 3 1/2" FIBERGLASS, SECURED IN PLACEFOR AT LEAST 10' FROM OPENING. SBC CA 713.4.
5. JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE-RATED WALLS, FLOORS ORFLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BEPROTECTED BY AN APPROVED FIRE-RESISTANT JOINT SYSTEM HAVING THE SAME FIRERATING AS THE ASSEMBLY IN OR BETWEEN WHICH IT IS INSTALLED. THE SYSTEMS SHALL BETESTED IN ACCORDANCE WITH SECTION 714.3.
6. OPENINGS IN FIRE-RESISTANCE-RATED WALLS SHALL BE PROTECTED, AND SHALLCOMPLY WITH THE TESTING, INSTALLATION, AND LABELING REQUIREMENTS OF SBC 715 ANDNFPA 80.
7. PENETRATIONS BY AIR DUCTS AND AIR TRANSFER OPENINGS IN FIRE-RESISTANCE-RATEDASSEMBLIES SHALL COMPLY WITH SBC SECTION 716.
8. FIREBLOCKING SHALL BE INSTALLED IN COMBUSTIBLE CONCEALED LOCATIONS ASSPECIFIED IN SECTION 717. ACCEPTABLE FIREBLOCKING MATERIALS ARE DESCRIBED IN717.2.1. FIREBLOCKING SHALL BE INSTALLED IN STUD WALLS, INCLUDING FURRED WALLS,VERTICALLY AT THE CEILING AND FLOOR LEVELS, AND HORIZONTALLY AT 10' INTERVALS.FIREBLOCKING SHALL ALSO BE INSTALLED AT CONNECTIONS BETWEEN VERTICAL STUD WALLSPACES AND THE HORIZONTAL SPACES CREATED BY A SERIES OF JOISTS; AT CONNECTIONSBETWEEN VERTICAL AND HORIZONTAL SPACES AT SOFFITS, DROPPED CEILINGS, ETC; ATCEILING AND FLOOR OPENINGS AROUND PIPES, DUCTS, ETC; BETWEEN EXTERIOR WALLFINISHES AND ARCHITECTURAL TRIM. SBC 717.2.
9. DRAFTSTOPPING IS NOT REQUIRED, IF THE BUILDING IS SPRINKLERED PER SBC 903.3.1.1.
10. REFER TO EGRESS NOTES, INTERIOR ENVIRONMENT NOTES, DOOR NOTES, WALLTYPES, AND DETAILS FOR ADDITIONAL REQUIREMENTS RELATED TO FIRE-RESISTANCERATED CONSTRUCTION.
FIRE PROTECTION SYSTEM NOTES1. AN AUTOMATIC SPRINKLER SYSTEM MEETING THE REQUIREMENTS OFSECTION 903.3.1.1 FOR NFPA 13 SPRINKLER SYSTEMS SHALL BE INSTALLEDTHROUGHOUT. QUICK-RESPONSE SPRINKLERS SHALL BE INSTALLED IN ALLDWELLING UNITS. SPRINKLER SYSTEMS PROTECTING DWELLING UNITS SHALLBE WET PIPE SYSTEMS PER SBC 903.3.2. SPRINKLERS IN LIVE/WORK UNITSSHALL BE DESIGNED FOR OH2 OCCUPANCY HAZARD. PLASTIC SPRINKLER PIPESHALL NOT BE USED IN LIVE/WORK AREAS.
2. THE SPRINKLER SYSTEM SHALL BE MONITORED BY A CENTRAL STATIONSERVICE APPROVED BY THE SEATTLE FIRE DEPARTMENT.
3. FIRE HOSE THREADS USED IN CONJUNCTION WITH AUTOMATIC SPRINKLERSYSTEMS AND STANDPIPE SYSTEMS SHALL BE COMPATIBLE WITH FIREDEPARTMENT HOSE THREADS. SBC 903.3.6 & 905.1.
4. STANDPIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION905, NFPA 14, AND RULES PROMULGATED BY THE BUILDING AND FIRE CODEOFFICIALS.
5. CLASS I STANDPIPES SHALL BE PROVIDED THROUGHOUT. HOSECONNECTIONS SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: AT EACHINTERMEDIATE LEVEL BETWEEN FLOORS IN EVERY STAIRWAY; AT EACH SIDEOF THE WALL ADJACENT TO A HORIZONTAL EXIT OPENING; IN EVERY EXITPASSAGEWAY AT THE ENTRANCE INTO OTHER PARTS OF THE BUILDING; ONTHE ROOF ADJACENT TO STAIR OPENINGS; OTHER REMOTE LOCATIONS ASSPECIFIED IN SBC 905.4. STANDPIPE LOCATIONS SHALL BE VERIFIED WITH THEBUILDING AND FIRE CODE OFFICIALS PRIOR TO INSTALLATION.
6. STANDPIPES SHALL BE INTERCONNECTED IN ACCORDANCE WITH NFPA 14.SBC 905.4.2. STANDPIPES SHALL HAVE ISOLATION VALVES AND SHALL HAVE ATWO-WAY FIRE DEPARTMENT CONNECTION VISIBLE AND ACCESSIBLE FROMTHE STREET NEAR THE SPRINKLER SYSTEM FIRE DEPT. CONNECTION.
7. THE OWNER SHALL BE RESPONSIBLE FOR PRODUCING A FIRE EMERGENCYGUIDE. THIS GUIDE SHALL DESCRIBE THE LOCATION, FUNCTION AND USE OFFIRE PROTECTION EQUIPMENT AND APPLIANCES ACCESSIBLE TO RESIDENTS,INCLUDING FIRE ALARM SYSTEMS, SMOKE ALARMS, AND PORTABLE FIREEXTINGUISHERS. THE GUIDE SHALL ALSO INCLUDE AN EMERGENCYEVACUATION PLAN FOR EACH DWELLING UNIT. THE EMERGENCY GUIDE SHALLBE REVIEWED AND APPROVED BY THE FIRE CODE OFFICIAL. A COPY OF THEEMERGENCY GUIDE SHALL BE GIVEN TO EACH TENANT PRIOR TO INITIALOCCUPANCY. SFC 408.9.
8. FIRE EXTINGUISHERS WITH A MINIMUM 2-A RATING SHALL BE LOCATEDWHERE SHOWN ON PLANS, AND SUCH THAT NO AREA IN THE BUILDING IS MORETHAN 75 FEET TRAVEL DISTANCE FROM A FIRE EXTINGUISHER. THE FIREEXTINGUISHERS SHALL BE LOCATED IN CONSPICUOUS LOCATIONS ALONGNORMAL PATHS OF TRAVEL. THEY SHALL NOT BE OBSTRUCTED OR OBSCUREDFROM VIEW. IN RESIDENTIAL CORRIDORS, FIRE EXTINGUISHERS SHALL BEHOUSED IN UNLOCKED CABINETS. IN GARAGES, FIRE EXTINGUISHERS SHALL BEMOUNTED ON SECURE HANGERS OR BRACKETS. SFC 906. SEE FLOOR PLANSFOR LOCATIONS.
9. A SINGLE, MANUAL AND AUTOMATIC FIRE ALARM SYSTEM SHALL BEDESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THEREQUIREMENTS OF SFC SECTION 907 AND NFPA 72.
10. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: ONTHE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THEIMMEDIATE VICINITY OF BEDROOMS, IN EACH ROOM USED FOR SLEEPINGPURPOSES, AND IN EACH STORY WITHIN A DWELLING UNIT. SMOKE ALARMSWITHIN AN INDIVIDUAL DWELLING UNIT SHALL BE INTERCONNECTED SUCH THATTHE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THEINDIVIDUAL UNIT. SFC 907.2.11.
11. SMOKE ALARMS SHALL BE POWERED BY THE BUILDING'S WIRING ANDALSO BE EQUIPPED WITH A BATTERY BACKUP. SFC 907.2.11.4.
12. MANUAL FIRE ALARM BOXES SHALL BE LOCATED NOT MORE THAN 5 FEETFROM THE ENTRANCE TO EACH EXIT AT EVERY FLOOR LEVEL. THE TRAVELDISTANCE TO THE NEAREST BOX SHALL NOT EXCEED 200 FEET. THE HEIGHT TOTHE ACTIVATING HANDLE OR LEVER OF THE BOX SHALL BE BETWEEN 42 AND 48INCHES ABOVE THE FLOOR. SFC 907.4.2.
13. ALL FIRE ALARM SYSTEMS IN BUILDINGS WITHOUT A FIRE COMMANDCENTER SHALL BE PROVIDED WITH AN ANNUNCIATOR PANEL OR THE MAIN FIREALARM CONTROL PANEL LOCATED INSIDE THE BUILDING AT THE MAINENTRANCE. ALARM PANELS AND ANNUNCIATORS SHALL NOT OBSTRUCTEXITING. SFC 907.6.3.1.
14. VISIBLE ALARM NOTIFICATION APPLIANCES SHALL BE PROVIDED IN ALLPUBLIC AND COMMON AREAS. ALL DWELLING UNITS SHALL BE PROVIDED WITHTHE CAPABILITY TO SUPPORT VISIBLE ALARM NOTIFICATION IN ACCORDANCEWITH ICC/ANSI 117.1. AUDIBLE ALARM NOTIFICATIONSYSTEMS SHALL HAVE ADISTINCT SOUND AND SHALL BE LOUD ENOUGH TO PROVIDE A SOUND-PRESSURE LEVEL AT LEAST 15 DECIBELS (DBA) ABOVE THE AMBIENT SOUNDOR 5 DBA ABOVE THE MAX SOUND LEVEL. SFC 907.5.2.
SOUND TRANSMISSION NOTES:1. AIR-BORNE SOUND: WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIESSEPARATING DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICEAREAS SHALL HAVE A SOUND TRANSMISSION CLASS (STC) OF NOT LESS THAN 50(45 IF FIELD TESTED). PENETRATIONS OR OPENINGS IN ONSTRUCTIONASSEMBLIES FOR PIPING, ELECTRICAL DEVICES, RECESSED CABINETS,BATHTUBS, SOFFITS, OR HEATING, VENTILATING OR EXHAUST DUCTS SHALL BESEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THEREQUIRED STC. UNIT ENTRY DOORS SHALL BE TIGHT FITTING TO THE FRAME ANDSILL. UNIT ENTRY DOOR ASSEMBLIES SHALL HAVE A STC OF NOT LESS THAN 28.SBC 1207.2.
2. STRUCTURE-BORNE SOUND: FLOOR/CEILING ASSEMBLIES SEPARATINGDWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREASSHALL HAVE AN IMPACT INSULATION CLASS (ICC) RATING OF NOT LESS THAN50 (45 IF FIELD TESTED) PER
3. JOINTS IN THE PERIMETER OF WALLS OR FLOOR/CEILING ASSEMBLIESSEPARATING DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICEAREAS SHALL BE ACOUSTICALLY SEALED WITH A PERMANENT RESILIENTMATERIAL APPROVED FOR SUCH PURPOSE. CONDUITS, DUCTS, PIPES ANDVENTS WITHIN SUCH WALL OR FLOOR/CEILING ASSEMBLIES CAUSING VIBRATIONSHALL BE REASONABLY ISOLATED FROM THE BUILDING CONSTRUCTION ATPOINTS OF SUPPORT. ALL OPENINGS THROUGH WHICH SUCH ITEMS PASS SHALLHAVE THE EXCESS OPENING FULLY SEALED. SBC 1207.3.
4. ELECTRICAL OUTLET BOXES SHALL NOT BE PLACED BACK-TO-BACK ANDSHALL BE OFFSET BY NOT LESS THAN 12 INCHES FROM OUTLETS IN THEOPPOSITE WALL SURFACE. THE BACK AND SIDES OF BOXES SHALL BE SEALEDWITH 1/8" RESILIENT SEALANT AND BACKED BY AT LEAST 2" THICK MATERIALFIBER INSULATION. SBC 1207.3.
5. SPACES OR SHAFTS CONTAINING AIR CONDITIONING, REFRIGERATION ORVENTILATING EQUIPMENT, ELEVATOR MACHINERY, OR OTHER MECHANICALEQUIPMENT SHALL BE SEPARATED BOTH VERTICALLY AND HORIZONTALLY FROMADJOINING DWELLING UNITS BY CONSTRUCTION DESIGNED TO PROVIDE AMINIMUM STC RATING OF 50. SBC 1207.6.
6. DESIGN AND MATERIALS FOR SOUND TRANSMISSION CONTROL SHALL NOTIMPAIR THE FIRE-RESISTANT INTEGRITY OF SEPARATING WALLS OR LOOR/CEILINGASSEMBLIES.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A0.1
115205.22.2013
AMMG1152_TRIAD 12TH
GENERAL NOTES
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
PLANTING AND SEATING AREA @ ENTRY1,038 SF
MR
ZONING CODE MATRIX
ZONE
UNIVERSITY DISTRICT NORTHWEST URBAN CENTER VILLAGE
NONE KNOWN
8,240 SF
BASE: 3.2 BASE4.25 * MAXIMUM*MAXIMUM F.A.R. PER SUSTAINABLE DESIGN AND AFFORDABLE HOUSING
REQUIREMENTS
INCENTIVES: (SMC 23.45.516; SMC 23.45.526; SMC 23.58A.014B*)*BASEMENT LEVEL NOT INCLUDED PER SMC 23.45.510.E.4.*GSF BASED ON GROSS FLOOR AREA DEFINITION PER SMC 23.84A.014.
PROPOSED: LEVEL 1: 4,237 GSFLEVEL 2: 4,622 GSFLEVELS 3-7 4,714 GSF X 5 = 23,570 GSFROOF: 398 GSF(32,827 GSF / 8,240 SF) = 3.98 F.A.R.
*Additional area is permitted per SMC 23.58A.014B because 17.5% of the net residential bonus area (960 sf)is provided as affordable housing:
INCENTIVE ZONING BASE F.A.R.: 3.2 = 26,368 GSFINCENTIVE ZONING MAX F.A.R: 4.25 = 35,020 GSFTOTAL PROPOSED FLOOR AREA: 32,827 GSF = 3.98 F.A.R.BONUS PROPOSED FLOOR AREA: 6,459 GSF = 0.78 F.A.R.NET TO GROSS FACTOR: 6,459 X .80 = 5,167 NSFREQUIRED AFFORDABLE HOUSING: 5,167 X .175 = 904 GSFPROVIDED AFFORDABLE HOUSING: 4 UNITS: UNIT B08 @ 246 NSF + UNIT 117 @ 255 NSF +
UNIT 217 @ 256 NSF + UNIT 317 @ 272 NSF = 1,029 NSF*GSF PER SMC 23.84A.014*See Sheets A2.0, A2.1, A2.2, A2.3 for designation of affordable housing units.
OVERLAY
ECA
LOT AREA
FLOOR AREA RATIOSMC 23.45.510
ALLOWED MAXIMUM STRUCTURE HEIGHT:BASE HEIGHT: 60'-0"MAXIMUM HEIGHT: 75'-0" * (RESIDENTIAL)+4' ALLOWED FOR PARAPETS: 79'-0"+15' ALLOWED FOR STAIR PENTHOUSE 90'-0"+16' ALLOWED FOR ELEVATOR PENTHOUSE 91'-0"* MAXIMUM HEIGHT PER SUSTAINABLE DESIGN AND AFFORDABILITY
INCENTIVES:(SMC 23.45.514; SMC 23.45.516; SMC 23.45.526)
STRUCTURE HEIGHT MEASUREMENT:AVERAGE GRADE LEVEL: +116'-1.25"
*SEE DIAGRAM FOR CALCULATION OF AVERAGE GRADE LEVEL (THIS SHEET).
PROPOSED MAXIMUM STRUCTURE HEIGHT (ABOVE AVERAGE GRADE LEVEL):TO TOP OF ROOF: 69'-1 3/4"TO TOP OF PARAPET: 73'-1 3/4"TO TOP OF ELEVATOR PENTHOUSE: 84'-7 3/4"
STRUCTURE HEIGHTSMC 23.45.514 &STRUCTURE HEIGHTMEASUREMENTSMC 23.45.006
FRONT SETBACK: • 7'-0" AVERAGE; 5'-0" MINIMUM • NO SETBACK REQUIRED IF A COURTYARD ABUTS STREET, AND THE COURTYARD ISMINIMUM 30% WIDTH OF ABUTTING STREET FRONTAGE OR 20', WHICHEVER IS GREATER,AND MINIMUM 20' DEEP MEASURED FROM STREET.
REAR SETBACK: • 10'-0" IF ABUTTING AN ALLEY
DEPARTURE REQUESTED FOR 0'-0" REAR SETBACK* SEE DEPARTURE MATRIX AND DIAGRAM (THIS SHEET).
SIDE SETBACK FROM INTERIOR LOT LINE: • FOR PORTIONS 42'-0" HIGH OR LESS: 7'-0" AVE. SETBACK; 5'-0" MIN. SETBACK • FOR PORTIONS HIGHER THAN 42'-0": 10'-0" AVE. SETBACK; 7'-0" MIN. SETBACK
DEPARTURE REQUESTED FOR:9'-5" AVERAGE SETBACK AT SOUTH PROPERTY LINE ABOVE 42'-0"9'-6" AVERAGE SETBACK AT SOUTH PROPERTY LINE ABOVE 42'-0"* SEE DEPARTURE MATRIX AND DIAGRAM (THIS SHEET).
FENCE HEIGHTS ARE LIMITED TO 6' IN SIDE YARD AND REAR YARDS AND 4' IN FRONT YARDS.
DEPARTURE REQUESTED TO ALLOW FOR A 7' FENCE AT BOTH SIDE YARDS AND A 7' SOLIDWALL AT THE REAR YARD FOR THE TRASH ENCLOSURE.
* SEE DEPARTURE MATRIX AND DIAGRAM (THIS SHEET).
SETBACKREQUIREMENTSSMC 23.45.518B
FENCE HEIGHT ATSIDE PROPERTYLINESMC 23.45.518.J.7
REQUIRED: 5% OF TOTAL GROSS FLOOR AREA OF A STRUCTURE IN RESIDENTIAL USE:
BASEMENT: 5,049 GSFLEVEL 1: 5,364 GSFLEVEL 2: 5,252 GSFLEVEL 3: 5,252 GSFLEVEL 4: 5,252 GSFLEVEL 5: 5,252 GSFLEVEL 6: 5,252 GSFLEVEL 7: 5,252 GSFROOF: 468 GSF42,393 GSF X .05 = 2,120 GSF REQUIRED
GENERAL REQUIREMENTS: • ALL UNITS SHALL HAVE ACCESS TO PRIVATE OR COMMON AMENITY AREA • NO MORE THAN 50% OF THE AMENITY AREA MAY BE ENCLOSED AND THIS ENCLOSED AREASHALL BE PROVIDED AS COMMON AMMENITY AREA • NO MINIMUM HORIZONTAL DIMENSION FOR PRIVATE AMENITY AREAS, EXCEPT 10' AT NON-STREET SIDE LOT LINES.
REQUIREMENTS FOR APARTMENTS, ROWHOUSES, AND TOWNHOUSES: • NO COMMON AMENITY AREA SHALL BE LESS THAN 250 SF IN AREA, AND COMMON
AMENITY AREAS SHALL HAVE A MINIMUM HORIZONTAL DIMENSION OF 10'. • MIN. 50% OF COMMON AMENITY AREA AT GROUND LEVEL SHALL BE LANDSCAPED. • SEATING, LIGHTING, OUTDOOR PROTECTION, ART, SHALL BE PROVIDED. • COMMON AMENITY AREA REQ'D AT GROUND LEVEL WILL BE ACCESSIBLE TO ALL UNITS.
PROVIDED:UNENCLOSED:GROUND LEVEL LANDSCAPE 1,038 GSFROOF TERRACE 1,554 GSFTOTAL 2,592 GSF
2,592 GSF / 42,393 GSF = 6.1% OF GROSS FLOOR AREA
AMENITY AREASMC 23.45.522
GREEN FACTOR SCORE MINIMUM 0.5 REQUIRED.
(SEE SHEET LANDSCAPE DRAWING SHEETS FOR CALCULATION)
LANDSCAPINGREQUIREMENTSSMC 23.45.524
NO PARKING REQUIRED FOR USES IN MULTI-FAMILY ZONES LOCATED IN URBAN CENTERS.BICYCLE LONG-TERM PARKING:
1 PER 4 UNITS102 UNITS/4 = 26 BIKE STALLS REQUIRED
> 30 BIKE STALLS PROVIDED
REQUIRED PARKINGSMC 23.49.019
MORE THAN 100 UNITS • 575 SF PLUS 4 SF FOR EACH ADDITIONAL UNIT ABOVE 100 • MIN. STORAGE AREA MAY BE REDUCED 15% IF MIN. HORIZONTAL DIM. IS 20'-0"
REQUIRED FOR 102 UNITS: 575 SF + (2 x 4 SF) = 583 SF x .85% = 496 SFPROVIDED: 450 SF
*SEE LETTER FROM SPU - DATED JUNE 1, 2012 (THIS SHEET)
SOLID WASTE &RECYCLABLEMATERIALS STORAGE& ACCESSSMC 23.45.040
MR ZONING CODE REQUIREMENT PROPOSED DEPARTURE AMOUNT REASON FOR DEPARTURE DESIGN REVIEW GUIDELINES
#1REAR SETBACKSMC 23.45.518B
#2SIDE SETBACKSSMC 23.45.518B
#3FENCE HEIGHTAT SIDEPROPERTY LINESMC 23.45.518.J.7
10'-0" min. from rear alley property line
7'-0" avg / 5'-0" min. below 42'-0"10'-0" avg / 7'-0" min. above 42'-0"
Fence heights are limited to 6' inside yard and rear yards and 4' infront yards.
0'-0"
• 9'-6" setback average at northproperty line above 42'-0"
• 9'-5" setback average at southproperty line above 42'-0"
Allow a 7' fence at both side yards,constructed from painted tube steelframe and open mesh inset panels,to provide an added sense ofsecurity. At the rear of the propertywhere the trash enclosure islocated, allow a 7' high solid wall,topped by a fabric canopy extending2' above the top of the wall toprovide complete screening of thetrash area.
1'-0" of additional fence height.
• 6" less avg side setback fornorth side above 42'-0"
• 7" less avg side setback forsouth side above 42'-0"
10'-0" To protect two significant trees at the front of the property, the building hasbeen located 15 feet off the front property line when the code requirement is a7 feet average minimum. As a result, the volume of the project has beenshifted to align with the edge of the alley as is consistent with the dormitorybuildings on the adjacent parcels to the south. The building volume is massedto provide the best site layout configuration and unit plans. This isaccomplished by utilizing the entire rear setback of the building while notmaximizing either the side or front setbacks. This site layout also allows thebuilding to concentrate open space at the front of the site where it is mostattractive and usable.
The code compliant side setbacks result in narrow side yards and an awkwardstep in the volume above the 42 feet height limit that is in contrast to the flat,unstepped facade of the adjacent dormitory building. The alternative schemerequiring departures provides more generous side setbacks than the codecompliant alternative. This serves to provide greater separation between adjacentbuildings and reduces the bulk of the project on the site. As with the rear setback,the project objective is to make the best use of the site and the buildingconfiguration by shaping the building in such a way that responds to siteconditions and adjacent properties.
The intent of the design is to create a visually open fence - a painted tube steel framesupporting an inset open mesh with small enough spacing to prevent getting a toe-hold.Raising the height of the fence to 7' from 6' would make climbing the fence more difficult,while the open mesh would maintain a visual connection. Planting along both side propertylines would add to the sense of screening and privacy while not completely removing thevisual connection from on-site to off-site.
At the rear of the building along the alley, a 7' high CMU wall would be constructed alongthe side and rear property lines at the trash enclosure. The adjacent apartment building tothe north currently has their dumpsters located adjacent to the proposed location of thissolid wall. The wall would be topped by a draped fabric canopy, extending 2' above the topof the wall, to obscure the view of the enclosure from above. 23.45.518j.7.b allows for anadditional 2' for "architectural features such as arbors or trellises on the top of a fence ispermitted, if the architectural features are predominantly open".
A-2 StreetscapeA-7 Open SpaceB-1 Hght, Bulk, ScaleD-1 Pedestrian SpaceE-2 LandscapingE-3 Special Site Conditions
A-2 StreetscapeA-7 Open SpaceB-1 Hght, Bulk, Scale
A-3 EntrancesC-4 Finish MaterialsD-6 Screening of DumpstersE-2 Landscaping
BONUS FLOORAREA FORAFFORDABLEHOUSINGSMC 23.58A.014
ROOF TERRACE1,554 SF
AMENITY AREAREQUIRED: 5% OF GROSS FLOOR AREA
OF RESIDENTIAL USE = 42,393 42,393 X .05 = 2,120 GSF REQUIRED
PROVIDED:
UNENCLOSED:GROUND LEVEL: PLANTINGS / SEATING 1,038 SFROOF LEVEL: TERRACE 1,554 SFTOTAL UNENCLOSED 2,592 SF
TOTAL AMENITY AREA PROVIDED:
2,592 SF / 42,393 SF = 6.1% GROSS FLOOR AREA
66' -
0" c
87' - 0" d
66' -
0" c
87' - 0" b
MIDPOINT: EXISTING GRADE (B)+118.25'
LINE OFENCLOSINGRECTANGLE
MIDPOINTELEVATION:A = 116'B = 118.25'C = 115'D = 114.88'
RECTANGLELENGTH:a = 66'b = 87'c = 66'd = 66'
(116' x 66') + (118.25' x 87') + (115 x 66') + (114.88 x 87)66 + 87 + 66 + 87
35528.31 / 306 = 116.10'
AVERAGE GRADE LEVEL = 116.10' OR 116'-1.25"
MIDPOINT: EXISTING GRADE (A)+116'
MIDPOINT: EXISTING GRADE (C)+115'
MIDPOINT: EXISTING GRADE (D)+114.88'
841 SF / 87' = 9'-6" AVERAGE86' - 7"
PROPERTY LINE
AWNING
841 SF
SIDE SETBACK:PROPOSED MIN BELOW 42'-0": 7'-0"PROPOSED MIN ABOVE 42'-0": 7'-0"PROPOSED AVG AT NORTH PROPERTY LINE: 9'-6"
REAR SETBACK:10'-0" MIN REQUIREDDEPARTURE REQUEST:0'-0" PROVIDED
SIDE SETBACK:PROPOSED MIN BELOW 42'-0": 7'-0"PROPOSED MIN ABOVE 42'-0": 7'-0"PROPOSED AVG AT SOUTH PROPERTY LINE: 9'-5"
829 SF
OUTLINE OFPROPOSED BUILDING
FRONT SETBACK:15'-0" PROVIDED
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A0.2
115205.22.2013
AMMG1152_TRIAD 12TH
ZONING
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1" = 30'-0"AMENITY AREA1
LEVEL 1 ROOF
SCALE: 1/16" = 1'-0"DIAGRAM: AVERAGE GRADE LEVEL4 SCALE: 1/16" = 1'-0"
DIAGRAM: SETBACKS5
1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
SEE SHEET A0.0 FOR A LIST OF APPLICABLE CODES
BUILDING CODE ANALYSIS
BUILDING CODE:
APARTMENT UNITS (RESIDENTIAL)
5 STORIES TYPE VA OVER2 STORIES TYPE 1A OVER1 BASEMENT TYPE 1A
R-2: APARTMENTSS-2: BIKE STORAGE AND UTILITYA: ASSEMBLY (ROOF DECK)
PROPOSED USE:
CONSTRUCTION:
THIS BUILDING WILL COMPLY WITH SBC 509.2 SUCH THAT THE FIRST STORY ABOVE GRADE WILL BE CONSIDERED A SEPARATEBUILDING FROM THE UPPER LEVELS, PROVIDED THAT ALL CONDITIONS ARE MET, INCLUDING THE REQUIREMENT THAT THEBUILDINGS ARE SEARATED WITH A HORIZONTAL ASSEMBLY HAVING A MINIMUM 3-HOUR FIRE-RESISTANCE RATING AND THEFIRST LEVEL IS OF TYPE 1 CONSTRUCTION.
BUILDINGOCCUPANCY:(SBC CH. 3)
TYPE IA HEIGHT & STORIES HEIGHT STORIESGROUP S-2 OC: ALLOWED UNLIMITED UNLIMITED
PROPOSED 9'-2" BASEMENT
GROUP R-2 OCC: ALLOWED UNLIMITED UNLIMITED PROPOSED 28'-4" BASEMENT + 2 STORIES
TYPE VA HEIGHT & STORIES HEIGHT STORIESGROUP R-2 OCC: ALLOWED 50' HEIGHT 4 STORIES
70' HEIGHT 5 STORIES SBC 504.2 SPRINKLER INCREASEPROPOSED 47'-11" 5 STORIES
BUILDING HEIGHT: PROPOSED 69'-1 3/4" MAX HEIGHT (PER SBC 502.1)
PER INTERPRETATION I 503A, THE UNENCLOSED AND UNCOVERED ROOF DECK SHALL NOT BECONSIDERED A STORY FOR THE PURPOSE OF DETERMINING THE NUMBER OF STORIES IN A BUILDING.
AREA CALCULATIONTYPE 1A AREA: GROUP S-2 GROUP R-2TABLE 503 LIMIT UNLIMITED UNLIMITEDPROPOSED MAX FLOORAREA/STORY 2,181 SF 3,178 SF @ BASEMENT + 5,369 SF @ L1 + 5,248 SF @ L2
AREA CALCULATIONTYPE VA AREA: GROUP R-2TABLE 503 LIMIT 12,000 SFSPRINKLER INCREASE PER 506.3 24,000 SFALLOWABLE AREA PER FLOOR 36,000 SFSTORY MULTIPLIER PER 506.4 X3MAX BUILDING AREA 108,000 SFPROPOSED MAX FLOORAREA/STORY 5,248 SF @ L3-L7 + 671 SF @ ROOFPROPOSED MULTI-STORY BUILDING AREA 42,887 SF
GENERAL BUILDINGHEIGHTS & AREAS:(SBC CH.5)TABLE 503
OCCUPANCY R S-2S-2 (SPRINKLERED) 1 HOUR NO REQUIREMENTR (SPRINKLERED) NO REQUIREMENT 1 HOUR
1 HOUR 1 HOUR
* REQUIRED SEPARATIONS SHALL BE FIRE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SBC707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED IN ACCORDANCE WITH SBC 712.1, OR BOTH SOAS TO COMPLETELY SEPARATE ADJACENT OCCUPANCIES.
REQUIREDSEPARATION OFOCCUPANCIES:TABLE 508.4
THIS BUILDING WILL COMPLY WITH EXCEPTION 1016.1.3 SUCH THAT A MAXIMUM 0F 50% OF THE EXITSIS PERMITTED TO BE MEASURED FROM THE MOST REMOTE POINT WITHIN A BUILDING TO AN EXITUSING UNENCLOSED EXIT ACCESS STAIRWAYS WHEN CONNECTING A MAXIMUM OF TWO STORIESPROVIDED THAT THE TWO CONNECTED STORIES SHALL BE PROVIDED WITH AT LEAST TWO MEANSOF EGRESS AND SHALL NOT BE OPEN TO OTHER STORIES.
THE AREA OF REFUGE IS NOT REQUIRED AT EXIT STAIRWAYS IN BUILDINGS EQUIPPED THROUGHOUTWITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR903.3.1.2 OR IN GROUP R-2 OCCUPANCIES.
DEAD END CORRIDOR = 50' PER SMC 1018.4.2
MEANS OFEGRESS:(SBC CH.10)
WHERE THE PORTION OF THE BUILDING BELOW THE 3 HOUR HORIZONTAL ASSEMBLY HAS 2'STORIES ABOVE GRADE PLANE,' 'EXIT ENCLOSURES' SHALL BE PRESSURIZED.
* ONLY 1 'STORY ABOVE GRADE PLANE' BELOW THE 3-HOUR HORIZONTAL ASSEMBLY - NO 'EXIT ENCLOSURE' PRESSURIZATION REQUIRED.
HORIZONTAL BLDGSEPARATIONALLOWANCE:TABLE 509.2
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
BUILDING ELEMENT TYPE 1A TYPE VAPRIMARY STRUCTURAL FRAME 3 HOUR 1 HOURINTERIOR/EXTERIOR BEARING WALLS 3 HOUR 1 HOUREXTERIOR NON-BEARING WALLS SEE TABLE 602 1 HOURINTERIOR NON-BEARING WALLS 0 HOUR 0 HOURFLOOR CONSTRUCTION 2 HOUR 1 HOURROOF CONSTRUCTION 1.5 HOUR 1 HOUR
CONSTRUCTIONTYPES:(SBC CH.6)TABLE 601
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATIONDISTANCE
FIRE SEPARATION TYPE 1A TYPE VADISTANCE R OCCUPANCY R OCCUPANCY< 5' 1 HOUR 1 HOUR> 5' & < 10' 1 HOUR 1 HOUR> 10' & < 30' 1 HOUR 1 HOUR>30' 0 HOUR 0 HOUR
* THE REQUIRED FIRE RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATION OFGREATER THAN TEN FEET SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE ONLY PER SBC705.5. FIRE SEPARATION DISTANCE IS THE DISTANCE FROM THE BUILDING FACE TO ONE OF THEFOLLOWING: THE CLOSEST INTERIOR LOT LINE, THE OPPOSITE SIDE OF A STREET, OR AN IMAGINARYLINE BETWEEN TWO BUILDINGS ON A PEOPERTY.
TABLE 602
ALL ASSEMBLIES SHALL MEET THE SBC REQUIREMENTS OR UL APPROVED TEST EQUIVALENT OF THEREQUIRED FIRE-RESISTIVE-RATING. SEE ASSEMBLY SCHEDULES FOR TESTING INFORMATION (SHEETSA10.00, A10.01 & A10.02)
RATED CONSTRUCTION REQUIREMETNS BY OCCUPANCYSBC 420.2 WALLS SEPARATING DWELLING UNITS 1 HOUR FIRE PARTITIONSBC 420.3 FLOOR ASSEMBLIES SEPARATING DWELLING UNITS 1 HOUR HORIZONTAL ASSEMBLYSBC 425.6 TRANSFORMER VAULT WALLS, FLOORS & CEILINGS 3 HOUR
RATED CONSTRUCTION REQUIREMENTS BY LOCATIONSBC 509.2 HORIZONTAL ASSEMBLY SEPARATING TYPE 1A 3 HOUR HORIZONTAL ASSEMBLY
AND TYPE VA CONSTRUCTIONSBC 509.2 SHAFT/STAIRWAY ENCLOSURES PENETRATING THRU 2 HOUR FIRE-RESISTANCE RATING
3 HOUR HORIZONTAL ASSEMBLYSBC 708.4 SHAFT ENCLOSURES CONNECTING MORE 2 HOUR FIRE BARRIER
THAN 4 STORIESSBC 708.4 SHAFT ENCLOSURES CONNECTING 4 1 HOUR FIRE BARRIER
STORIES AND FEWER
RATED CONSTRUCTION REQUIREMENTS FOR EXIT COMPONENTSSBC 1018.1 CORRIDORS - R OCCUPANCY (MOST RESTRICTIVE) 1 HOUR FIRE PARTITIONSBC 1022.1 EXIT ENCLOSURE CONNECTING MORE THAN 4 STORIES2 HOUR FIRE BARRIERSBC 1022.1 EXIT ENCLOSURE CONNECTING 4 OR LESS STORIES 1 HOUR FIRE BARRIERSBC 1023.3 EXIT PASSAGEWAYS (MATCH CONNECTING EXIT ENCL.)1 HOUR FIRE BARRIER MIN
FIRE-RESISTANCERATEDCONSTRUCTION:(SBC CH. 7)
STAIR A LEVEL FUNCTION LOAD FACTORPER OCCUPANT
OCCUPANTLOAD
55
55
55
55
55
RF
L6
L5
L4
L3
15 SF/OCC
200 SF/OCC
200 SF/OCC
200 SF/OCC
200 SF/OCC
200 SF/OCC
ASSEMBLY/UNCONCENTRATED
R-2
TOTAL THIS LEVEL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
28
28
28
28
107
3
110
STAIR B
55
55
55
55
55
55
68
13
L2
L1
B1
200 SF/OCC
200 SF/OCC
200 SF/OCC
200 SF/OCC
200 SF/OCC
RESIDENTIAL
RESIDENTIAL
TOTAL THIS LEVEL
RESIDENTIAL
STORAGE/XFRMR
BIKE PARKING
TOTAL THIS LEVEL
55
67
12
3-HR SEPARATION
55
14
14
14
14
55
14
14
14
14
14
15
13
28
29
29
14
14
12
15
7
3
25
LEVELOF DISCHARGE
LEVELOF DISCHARGE
BUILDING CODE ANALYSIS KEY
3-HR ASSEMBLY
2-HR ASSEMBLY
1-HR ASSEMBLY
NOTE: SEE DIAGRAMS FOR ASSEMBLY TYPE,SUCH AS EXTERIOR WALL, FIREWALL, ETC.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A0.3
115205.22.2013
AMMG1152_TRIAD 12TH
BUILDING CODE -ANALYSIS +DIAGRAMS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1" = 1'-0"DIAGRAM: OCCUPANCY CALCULATIONS1
3 BP CORRECTION 02.28.13
UP
1-HR EXTERIORWALL RATED FOR
EXPOSURE TOFIRE FROM THE
INSIDE ONLY
1-HR EXTERIORWALL RATED FOREXPOSURE TO FIREFROM BOTH SIDES
3-HR EXTERIORFIRE WALL
@ STAIR TOWER
2-HR FIRE WALL@ ELEVATOR
(SHAFT ENCLOSURE)
1-HR FIRE PARTITIONSEPARATION
BTWN R-2 AND B
1-HR FIRE PARTITIONBTWN UNITS, TYP.
LEVEL 1
1-HR EXTERIORWALL RATED FOREXPOSURE TOFIRE FROM BOTHSIDES
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMTHE INSIDE ONLY
1-HR FIREPARTITION @CORRIDORWALLS, TYP.
SEPARATIONDISTANCEBTWN EXITS= 75'-0"
2-HR EXTERIORFIRE WALL@ STAIR TOWER
REFUSE/RECYCLE
R-2
305 SF2 OCC.
(ACCESSORY)
R-2285 SF2 OCC.
R-2292 SF2 OCC.
R-2296 SF2 OCC.
R-2292 SF2 OCC.
R-2292 SF2 OCC.
R-2290 SF2 OCC.
R-2292 SF2 OCC.
R-2351 SF2 OCC.
R-2321 SF2 OCC.
R-2312 SF2 OCC.
R-2323 SF2 OCC.
LOBBYR-2
650 SF4 OCC.
LONGEST COMMONPATH OF EGRESSTRAVEL DISTANCE = 55'-5" (MAX 125' ALLWED INR-2 OCCUPANCY)
48' - 3 3/4"
EXITDISCHARGE
STAIRA
STAIR B
ELEV.
1/3" = 36'-0" M
IN. REQ'D SEPARATION
106' - 3"
3-HR RATEDTRANSFORMEREXHAUST SHAFT
EXITDISCHARGE
1-HR EXTERIORWALL RATED FOR
EXPOSURE TOFIRE FROM THE
INSIDE ONLY
1-HR EXTERIORWALL RATED FOREXPOSURE TO FIREFROM BOTH SIDES
2-HR EXTERIORFIRE WALL
@ STAIR TOWER
2-HR FIRE WALL@ ELEVATOR
(SHAFT ENCLOSURE)
1-HR FIRE PARTITIONBTWN UNITS, TYP.
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMBOTH SIDES
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMTHE INSIDE ONLY
1-HR FIREPARTITION @CORRIDORWALLS, TYP.
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMTHE INSIDEONLY
SEPARATIONDISTANCEBTWN EXITS= 75'-0"
2-HR EXTERIORFIRE WALL@ STAIR TOWER
R-2292 SF2 OCC.
R-2292 SF2 OCC.
R-2296 SF2 OCC.
R-2293 SF2 OCC.
R-2293 SF2 OCC.
R-2290 SF2 OCC.
R-2293 SF2 OCC.
R-2351 SF2 OCC.
R-2321 SF2 OCC.
R-2312 SF2 OCC.
R-2313 SF2 OCC.
LONGEST COMMONPATH OF EGRESSTRAVEL DISTANCE = 55'-5" (MAX 125' ALLWED INR-2 OCCUPANCY)
R-2350 SF2 OCC. R-2
313 SF2 OCC.
R-2322 SF2 OCC.
LEVEL 3-7
48' - 10 1/4"
STAIRA
STAIR B
ELEV.
1/3" = 36'-0" M
IN. REQ'D SEPARATION
106' - 3"
3-HR RATEDTRANSFORMEREXHAUST SHAFT
1-HR EXTERIORWALL RATED FOR
EXPOSURE TOFIRE FROM THE
INSIDE ONLY
1-HR EXTERIORWALL RATED FOREXPOSURE TO FIREFROM BOTH SIDES
2-HR FIRE WALL@ ELEVATOR
(SHAFT ENCLOSURE)
1-HR FIRE PARTITIONBTWN UNITS, TYP.
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMBOTH SIDES
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMTHE INSIDE ONLY
1-HR FIREPARTITION @CORRIDORWALLS, TYP.
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMTHE INSIDEONLY
SEPARATIONDISTANCEBTWN EXITS= 75'-0"
R-2292 SF2 OCC.
R-2292 SF2 OCC.
R-2296 SF2 OCC.
R-2321 SF2 OCC.
R-2312 SF2 OCC.
R-2313 SF2 OCC.
LONGEST COMMONPATH OF EGRESSTRAVEL DISTANCE = 55'-5" (MAX 125' ALLWED INR-2 OCCUPANCY)
R-2350 SF2 OCC.
R-2313 SF2 OCC.
R-2322 SF2 OCC.
LEVEL 2
48' - 5 1/2"
R-2293 SF2 OCC.
R-2293 SF2 OCC.
R-2290 SF2 OCC.
R-2293 SF2 OCC.
R-2351 SF2 OCC.
3-HR EXTERIORFIRE WALL
@ STAIR TOWER
2-HR EXTERIORFIRE WALL@ STAIR TOWER
STAIRA
STAIR B
ELEV.
3-HR RATEDTRANSFORMEREXHAUST SHAFT
1/3" = 36'-0" M
IN. REQ'D SEPARATION
106' - 3"
1-HR EXTERIORWALL RATED FOR
EXPOSURE TOFIRE FROM THE
INSIDE ONLY
1-HR EXTERIORWALL RATED FOREXPOSURE TO FIREFROM BOTH SIDES
3-HR FIRE WALL@ STAIR TOWER
2-HR FIRE WALL@ ELEVATOR
(SHAFT ENCLOSURE)
1-HR FIRE PARTITIONSEPARATION BTWN
S-2 & R-2
1-HR FIRE PARTITIONBTWN UNITS, TYP.
1-HR EXTERIORWALL RATED FOREXPOSURE TOFIRE FROM BOTHSIDES
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMTHE INSIDE ONLY
1-HR FIREPARTITION @CORRIDORWALLS, TYP.
1-HR EXTERIORWALL RATEDFOR EXPOSURETO FIRE FROMTHE INSIDEONLY
SEPARATIONDISTANCEBTWN EXITS= 75'-0"
LONGEST COMMONPATH OF EGRESSTRAVEL DISTANCE = 55'-5" (MAX 125' ALLWED INR-2 OCCUPANCY)
1-HR FIREPARTITION OCC.
SEPARATIONBTWN S-2 & R-2
3-HR FIRE WALL(TRANSFORMER
ROOM)
R-2293 SF2 OCC.
R-2293 SF2 OCC.
R-2286 SF2 OCC.
R-2293 SF2 OCC.
R-2351 SF2 OCC. R-2
321 SF2 OCC.
R-2313 SF2 OCC.
BIKE STORAGES-2
639 SF3 OCC.
TENANTSTORAGE
S-2384 SF2 OCC.
TRANSFORMERACCESS WELL
S-2203 SF
1 OCC.
TRANSFORMERROOM
S-2355 SF2 OCC.
LEVEL B1
MTR RM R-2131SF1
OCC.
TELECOMR-2
54 SF1 OCC.
SPRINKLERRISER ROOM
R-2114 SF1 OCC.
2-HR FIRE WALL@ STAIR TOWER
1-HR FIRE PARTITIONSEPARATION BTWN
S-2 & R-2
STAIRA
STAIR B
ELEV.
1/3 = 35'-6" MIN. R
EQ'D. SEPARATION
106' - 4 1/4"
49' - 3"1/3 = 27'-0" MIN. REQ'D SEPARATION
80' - 6"
BOILERR-2
123 SF1 OCC.
(ACCESSORY)
MECHR-2
50 SF1 OCC.
(ACCESSORY)
A-31604 SF
107 OCC.
R-2192 SF1 OCC.
ROOF
ELEV. 2-HR FIREBARRIER @ELEVATORTOWER(SHAFTENCLOSURE)
SEPARATIONDISTANCE BTWNEXITS = 109'-0"
RATED WALL KEY
1-HR WALL
2-HR WALL
3-HR WALL
PATH OF EGRESS
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A0.4
115205.22.2013
AMMG1152_TRIAD 12TH
BUILDING CODE -ANALYSIS +DIAGRAMS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/16" = 1'-0"DIAGRAM: OCCUPANCIES, AREAS, EXITING & FIRE SEPARATIONS1
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
UP
UP
UP
A3.01
A3.0
A3.1
A3.1
1
2
2
1A4.0
1A4.0
2A4.0
2A4.0
B16TRANSFORMER VAULT
B13STUDIO
UNIT C.1 ON A5.3
B12STUDIO
UNIT B.1 ON A5.2
B11STUDIO
UNIT B.1 ON A5.2
B10STUDIO
UNIT B.1 ON A5.2 B09STUDIO
UNIT B.4 ON A5.2
B08STUDIO
UNIT A.3 ON A5.1
B07STUDIO
UNIT A.2 ON A5.1
B06
BICYCLEPARKING
B17
TENANTSTORAGE
B00STAIR A
B02ELEV
B01STAIR B
10' -
0"
10' -
0"
2' -
11"
B03CORR.
T.O. SLABELEV:
PATIO PATIO PATIO PATIO PATIO
012
010
004
001
009
D
D
005
C1
C1C1
C2C2C2
C1C1
C1
C1
C1 B6
B6
C2
C2
A7.12
5
5
AA
BB
C C
D D
E
E
F F
6
62
2
A7.23
1
1
3
3
4
4
86' - 2"
2A-FE
CANOPY ABOVE
74' -
10"
57' - 2" 5' - 3" 8' - 3" 15' - 6" 5' - 0"
5' -
11"
12' -
11"
13' -
1"
36' -
3"
3' -
0"
3A8.0
1A8.0
2A8.0
A7.01
EXIT
EXIT
EXIT
EXIT
U5 LL U5U5 LLU5
2' - 5"
2' -
2"
2' -
2"
B04
SPRINKLERROOM
WINDOWWELL
5'-0
" CLR
.
5'-0" CLR.
B18METER
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
18' - 1" 6' - 9" 14' - 1" 9' - 8" 8' - 9" 5' - 1"
3' -
11"
19' -
1"
7' -
2"12
' - 1
0"6'
- 0"
17' -
2"
8' -
8"
1' - 5 3/4"
13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"
1' -
0"
2' -
11"
B05TELECOM
106' - 1"
16' -
11"
15' -
1"
23' -
4"
6' -
10"
3' -
6"
T.O. SLABELEV:
109' - 1"
109' - 1"T.O. SLABELEV:
109' - 1"T.O. PATIOELEV:
002
006
R
A5.41
C2C2
C3
C1
C1
C2
C3
C2
C1
C2
B4
B4 B4 B4
C2
B4
B1B1
B6
C2
C2C2
B4
C2
B3
008
B3003
011
15' -
7"
23' - 6"
A9.79
1' - 6"
B6
SHAFTABOVE
C1
L U5
115' - 6"T.O. WALLELEV.
C2C2
B6
12' -
0"
A9.715
A9.113
B14
TRANSFORMERVESTIBULE
115' - 6"T.O. WALLELEV.
4A5.4
5A5.4
4A8.0
B6
DN
A 3.1
1
A 3.0
A 3.0
A 3.1 2
AFFORDABLEHOUSING UNIT
A9.21
4' - 10"
12" MIN
007
7' -
5"
B15
TRANSFORMERACCESS WELL
SLOPE SLAB 1/8" PER FT. MIN.
SLOPE SLAB1/8" PER FT. MIN.
A9.112
PROVIDE CONCRETEWALLS W/ LID TO HOUSEMECH. INTAKE + LOUVERPER SHEET M2.1
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL
GENERAL FLOOR PLAN NOTES:
• NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.0
115205.22.2013
SL, AMMG1152_TRIAD 12TH
FLOOR PLAN -BASEMENT
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"LEVEL B11
NORTH
UNIT AREAS - LEVEL B1UNIT NET SF GROSS SF
B07 271 SF 313B08 246 SF 310B09 252 SF 300B10 258 SF 295B11 258 SF 295B12 258 SF 295B13 269 SF 339 1 MUP CORRECTION 09.10.12
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
5
5
AA
BB
C C
D D
EE
F F
6
62
21
1
3
3
4
4
2' -
11"
T.O. SLABELEV:
86' - 2"
74' -
10"
57' - 2" 5' - 3" 8' - 3" 15' - 6" 5' - 0"
5' -
11"
3' -
0"
2' - 5"
3' -
5"
2' -
2"
2' -
2"
WIN
DO
W W
ELL
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
18' - 1" 8' - 9"
3' -
11"
19' -
1"
7' -
2"12
' - 1
0"6'
- 0"
17' -
2"
8' -
8"
7' -
6"8'
- 5"
1' -
3"
1' -
0"2'
- 11
"106' - 1"
23' -
4"
6' -
10"
T.O. SLABELEV:
109' - 1"
109' - 1"T.O. SLABELEV:
109' - 1"T.O. PATIOELEV:
T.O. STAIRELEV. 114' - 9"
115' - 6"T.O. WALLELEV:
115' - 6"T.O. WALLELEV:
1' - 6"
1' - 7"
TRANSFORMERACCESS HATCH
ABOVE
1' - 3" 3' - 0" 2' - 10"
T.O. SILLELEV:
3' - 0"2' - 10"
3' - 8" 4' - 3"2' - 10"
3' - 0"1' - 8"
3' - 0"
T.O. SILLELEV:
T.O. SILLELEV:
1' - 4"2' - 10"3' - 0"
3' -
10"
9' - 5"7"
3' -
8"
4' -
0"
20' -
0"
3' -
4"
-
-
111' - 3"111' - 3" 111' - 3"111' - 3"111' - 3"
16' -
1"
8' - 9"
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.0S
115205.22.2013
AuthorChecker1152_TRIAD 12TH
SLAB PLAN -BASEMENT
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"LEVEL B1 - SLAB1
UP
UP
A3.01
A3.0
A3.1
A3.1
1
2
2
1A4.0
1A4.0
2A4.0
2A4.0
113STUDIO
UNIT C.1 ON A5.3
112STUDIO
UNIT B.1 ON A5.2
111STUDIO
UNIT B.1 ON A5.2
110STUDIO
UNIT B.1 ON A5.2 109STUDIO
UNIT B.4 ON A5.2
108STUDIO
UNIT A.3 ON A5.1
107LOBBY
UNIT A.2 ON A5.1
115STUDIO
UNIT B.3 ON A5.2
100STAIR A
102ELEV
106STUDIO
UNIT A.2 ON A5.1
116STUDIO
UNIT B.2 ON A5.2 117STUDIO
UNIT B.5 ON A5.369
' - 6
"
118LOBBY
114
REFUSE/RECYCLING
AREA
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
101STAIR B
103CORR.
BLD
G.
EXIT
FIN. GRADEELEV: 116'-8 1/2"
118' - 3"T.O. SLABELEV.
115' - 6"T.O. WALLELEV.
6' -
10"
23' -
4"
16' -
1"
10' -
4"
19' -
9"
PATIO PATIO PATIO PATIO PATIO
10' -
0"
10' -
0"
WIN
DO
W W
ELL
BEL
OW
12TH
AVE
NU
E N
E
ALLE
Y
T.O. STAIRELEV. 114' - 9"
DECORATIVEPROJECTINGBUILDING FINSABOVE
DECORATIVEPROJECTING
BUILDING FINSABOVE
106
107
FF F
A
H
H
H
120BATH
119
CONCIERGEOFFICE
104
B6
26' -
2"
12' -
10"
13' -
4"
12' -
11"
A7.13
86' - 2"
5
5
AA
BB
C C
D D
E
E
F F
6
62
2
A7.24
100
1
1
3
3
4
4
2A-FE
BLDG.ENTRY
CANOPYBELOW
METALGATE
DECORATIVE METALSECURITY GATE
DECORATIVEMETAL GATE
7' SCREEN FENCE @PROPERTY LINE
7' SCREEN FENCE @PROPERTY LINE
7' SCREENFENCE @PROPERTYLINE
A5.01
3A8.0
1A8.0
2A8.0
C4
C1C1
EXIT
EXIT
EXIT
EXIT
EXIT
L L L
E.1
U5 U5 U5 MAILBOXES
1' - 7"
7' -
6"
7' -
3"3'
- 5"
10' -
2"
17' -
2"
6' -
0"12
' - 1
0"7'
- 2"
19' -
1"
5'-0
" CLR
.
5'-0" CLR.
57' - 2" 5' - 3" 23' - 9"
13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"
18' - 1" 7' - 11" 10' - 10" 11' - 9" 8' - 1" 5' - 9" 15' - 9" 8' - 0"
118' - 3"T.O. F.F.ELEV:
VESTIBULE
103
105
5'-0" CLR.
Q
P
L
M
OC2C2
C1
B4 B4 B4 B4
C2C2C2
E4
B4
B4
B4
B3
B6
C2C2
C1C1
C2 C2
C2
B4 B4 C2 C2C2
E4
E4
AWNINGABOVE(SBO)
A9.79
UP
UP
EXITDISCHARGE
8 CUBIC YARDDUMPSTER
8 CUBIC YARDDUMPSTER
TRANSFORMERACCESS HATCH
115' - 6"T.O. WALLELEV:
116' - 9"T.O. SLAB @ LANDINGELEV:
B6
A9.715
39' -
9"
25' -
6"
115' - 6"T.O. WALLELEV.
5' - 0" 5' - 0" 5' - 0" 5' - 0"
4A5.4
5A5.4
F
7' SCREEN FENCE@ PROPERTY LINE
C1
4A8.0
BENCH PERLANDSCAPE DRAWINGS
BENCH
A 3.1
1
A 3.0
A 3.1 2
AFFORDABLEHOUSING UNIT
A9.21
42" GUARDRAIL
42" GUARDRAIL
EXIT N
101102
5
A9.0
A9.22
A9.411
4
A9.0
A9.112
A9.113
A6.01
MECH.WELL
MECH.WINDOWWELL
2' - 8"
2' -
8" 12"
11' - 1" 2' - 8" 10' - 2"
2' -
8"
PROVIDE CONCRETEWALLS W/ LID TO HOUSEMECH. INTAKE + LOUVER
PER SHEET M2.1
1 HR. RATEDCEILING BELOW
PLUMBING PIPES
U
MAILBOXES
AFFORDABLE HOUSING REQ'D: 1,080 GSFAFFORDABLE HOUSING TABLE
LEVEL B1 UNIT B08 246 NSF 310 GSF
LEVEL 1 UNIT 117 255 NSF 314 GSF
LEVEL 2 UNIT 217 256 NSF 318 GSF
LEVEL 3 UNIT 317 272 NSF 320 GSF
AFFORDABLE HOUSING PROVIDED: 1,029 NSF; 1,262 GSF
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL
GENERAL FLOOR PLAN NOTES:
•
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.1
115205.22.2013
SL, AMMG1152_TRIAD 12TH
FLOOR PLAN -LEVEL 1
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
NORTH
SCALE: 1/8" = 1'-0"LEVEL 1 (TYPE 1A)1
UNIT AREAS - LEVEL 1UNIT NET SF GROSS SF
106 277 SF 325108 259 SF 317109 249 SF 300110 255 SF 294111 255 SF 294112 255 SF 294113 266 SF 339115 247 SF 305116 257 SF 294117 253 SF 314
1 MUP CORRECTION 09.10.122 MUP CORRECTION 2 01.21.133 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
5
5
AA
BB
C C
D D
E
E
F F
6
62
21
1
3
3
4
4
69' -
6"
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
116' - 9"FIN. GRADEELEV:
118' - 3"T.O. SLABELEV.
115' - 6"T.O. WALLELEV.
2' -
11"
23' -
4"
36' -
0"
WIN
DO
W W
ELL
BEL
OW
12TH
AVE
NU
E N
E
T.O. STAIRELEV. 114' - 3"
26' -
2"
12' -
10"
86' - 2"
1' - 7"
3' -
1"4'
- 0"
2' -
11"
2' -
2"3'
- 0"
10' -
2"
17' -
2"
6' -
0"12
' - 1
0"7'
- 2"
19' -
1"
57' - 2" 5' - 3" 23' - 9"
18' - 1" 23' - 9"
118' - 3"T.O. F.F.ELEV:
T.O. WALLELEV:
9' -
0"
8' - 5"
ELEVATOR SHAFT
TRANSFORMEREXHAUST SHAFT
TRANSFORMERINTAKE SHAFT
119' - 1"119' - 1"T.O. SILLELEV:
119' - 1"119' - 1"T.O. SILLELEV:
1' - 6"
7' -
3"
120' - 2"
118' - 8"
T.O. CURBELEV:
T.O. CURBELEV:
2' - 5"
4' -
0"
118' - 10"
12"
24' -
6"
8"12
"
2' -
5"16
' - 1
0 1/
4"
3' - 7"
2' - 9"
TRANSFORMERACCESS HATCH
ABOVE2' - 10" 3' - 0"
1' - 6"3' - 0" 2' - 10" 2' - 10" 3' - 0" 1' - 9"
125' - 3"
118' - 3"T.O. SLABELEV:
T.O. WALLELEV: 125' - 3"
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.1S
115205.22.2013
AuthorChecker1152_TRIAD 12TH
SLAB PLAN - LEVEL 1
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"LEVEL 1 (TYPE 1A)1
A3.01
A3.0
A3.1
A3.1
1
2
2
1A4.0
1A4.0
2A4.0
2A4.0
212STUDIO
UNIT B.1 ON A5.2
211STUDIO
UNIT B.1 ON A5.2
210STUDIO
UNIT B.1 ON A5.2 209STUDIO
UNIT B.4 ON A5.3
208STUDIO
UNIT A.5 ON A5.1
207STUDIO
UNIT A.2 ON A5.1
215STUDIO
UNIT B.2 ON A5.2
201STAIR B
200STAIR A
202ELEV
204STUDIO
UNIT A.5 ON A5.1
205STUDIO
UNIT A.1 ON A5.1
206STUDIO
UNIT A.2 ON A5.1
216STUDIO
UNIT B.2 ON A5.2217
STUDIOUNIT B.5 ON A5.3214
STUDIOUNIT D.1 ON A5.3
203CORR.
59' -
4"
23' -
4"
15' -
3"
20' -
9"
13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"
AWNINGBELOW(SBO)
201
200
A
J
J
J
H
H
FA
A
B
A
E.5
E.1
5
5
AA
BB
C C
D D
E
E
F F
6
62
2
A7.25
K K K K
K K K K K
1
1
3
3
4
4
2A-FE
213STUDIO
UNIT C.2 ON A5.3
A7.14
3A8.0
1A8.0
2A8.0
EXIT
EXIT
EXIT
EXIT
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
1' - 6"
17' -
2"
6' -
0"12
' - 1
0"7'
- 2"
19' -
1"
5'-0" CLR.
5'-0
" CLR
.
5'-0" CLR.
57' - 2" 5' - 3" 23' - 9"
65' -
2"
86' - 2"
13' -
1"
12' -
11"
13' -
0"
13' -
1"
13' -
1"
48' - 7" 23' - 9"
15' - 2" 10' - 10" 10' - 10" 11' - 9" 8' - 1" 5' - 9"
2' -
11"
128' - 3"T.O. F.F.ELEV:
B4 B4B4
E4
E4
E4
B4B4
B4 B4
C2E4
E4
E4
E4
C2
C1
B6
B6
B3
B6B6
E4
E4E4E4
E4
E4
B4
B4
B4
B4
E3
C1
A9.79
5'-0" CLR.
UP
UP
CHASE TERMINATESUNDER LEVEL 3COUNTER. SEE UNITD.2 ON A5.3 FORLEVELS 4-7.
B7
A9.43
A9.715
5A5.4
4A8.0
A 3.1
1
A 3.0
A 3.0
A 3.1 2
A9.21
AFFORDABLEHOUSING UNIT
A9.49
SIM
A9.410
A9.24
A9.113
A9.61
A9.22
1' -
3"
A9.113
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL
GENERAL FLOOR PLAN NOTES:
• NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.2
115205.22.2013
SL, AMMG1152_TRIAD 12TH
FLOOR PLAN -LEVEL 2
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"LEVELS 2 (TYPE 1A)1
NORTH
UNIT AREAS - LEVEL 2UNIT NET SF GROSS SF
204 260 SF 319205 274 SF 316206 274 SF 316207 274 SF 316208 257 SF 317209 256 SF 304210 259 SF 296211 259 SF 296212 259 SF 296213 280 SF 346214 257 SF 330215 258 SF 298216 259 SF 296217 254 SF 318
1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
5
5
AA
BB
C C
D D
EE
F F
6
62
21
1
3
3
4
4
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
17' -
2"
6' -
0"12
' - 1
0"7'
- 2"
19' -
1"
86' - 2"
128' - 3"T.O. F.F.ELEV:
C2
57' - 2" 5' - 3" 23' - 9"
65' -
2"
2' -
11"
59' -
4"
2' -
11"
23' -
4"
28' -
11"
3' -
1"4'
- 0"
48' - 5" 4' - 6" 3' - 9" 5' - 9" 23' - 9"
9' -
0"
8' - 5"
ELEVATORSHAFT
TRANSFORMEREXHAUST SHAFT
4' -
10"
7' -
9"
7' -
8"5'
- 0"
2' -
0"11' -
9"
4' -
4"
4' - 6" 3' - 9"
16' -
0"
2' - 9"
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.2S
115205.22.2013
AuthorChecker1152_TRIAD 12TH
SLAB PLAN - LEVEL 2
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"LEVELS 2 (TYPE 1A)1
A3.01
A3.0
A3.1
A3.1
1
2
2
1A4.0
1A4.0
2A4.0
2A4.0
312STUDIO
UNIT B.1 ON A5.2
311STUDIO
UNIT B.1 ON A5.2
310STUDIO
UNIT B.1 ON A5.2309
STUDIOUNIT B.4 ON A5.2
308STUDIO
UNIT A.4 ON A5.1
307STUDIO
UNIT A.2 ON A5.1
301STAIR B
300STAIR A
302ELEV
303CORR.
305STUDIO
UNIT A.1 ON A5.1
304STUDIO
UNIT A.4 ON A5.1
306STUDIO
UNIT A.2 ON A5.1
316STUDIO
UNIT B.2 ON A5.2
317STUDIO
UNIT B.6 ON A5.3
314STUDIO
UNIT D.1 ON A5.3
59' -
4"
23' -
4"
15' -
3"
20' -
9"
13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"
57' - 2" 5' - 3" 23' - 9"
13' -
1"
13' -
1"
13' -
1"
13' -
1"
12' -
11"
7' -
5"
301
300
B
A
E.2
A
J
J
J
J
A
A
E.1
A7.15
5
5
AA
BB
C C
D D
E
E
F F
6
62
2
A7.26
K K K K
K K K K K
1
1
3
3
4
4
2A-FE
313STUDIO
UNIT C.3 ON A5.3
3A8.0
1A8.0
2A8.0
EXIT
EXIT
EXIT
EXIT
5'-0" CLR.
5'-0
" CLR
.
5'-0" CLR.
4' - 10 1/2"
15' - 2" 10' - 10" 10' - 10" 11' - 9" 8' - 1" 5' - 9"
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
86' - 2"
48' - 7" 23' - 9"
19' -
1"
7' -
2"12
' - 1
0"6'
- 0"
17' -
2"
I
E2E2
E1
E1
E2
E2
E2
E1
E2E2
E1
E1
E3
E3E3
A4
A4
A4
A6
A3
A6A6
A5 B8
E3
A5
E3
E3
A6
A6
A3A4 A4 A4 A4
E2E1E2
A4
A4
A4
A4315
STUDIOUNIT B.2 ON A5.2
UP
UP
A9.44A9.4
10A9.6
1
A9.715
5A5.4
SEE UNIT A.6ON SHEET A5.1FOR UNITS 406+ 706 ONLEVELS 4 + 7
12" M
IN.
12" M
IN.
7' -
2"
4A8.0
A 3.1
1
A 3.0
A 3.0
A 3.1 2
7' -
2"
1' - 2 3/4"
1' - 2 3/4"
AFFORDABLEHOUSING UNIT
317
A9.21
A9.22
A9.23
CHASE TERMINATESUNDER LEVEL 3COUNTER. SEE UNITD.2 ON A5.3 FORLEVELS 4-7.
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL
GENERAL FLOOR PLAN NOTES:
•
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.3
115205.22.2013
SL, AMMG1152_TRIAD 12TH
FLOOR PLAN -LEVELS 3-7
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
NORTH
SCALE: 1/8" = 1'-0"LEVELS 3-7 (TYPE V)1
UNIT AREAS - LEVELS 3-7UNIT NET SF GROSS SF
LEVEL 3304 274 SF 319305 280 SF 316306 279 SF 316307 279 SF 316308 271 SF 317309 260 SF 304310 261 SF 296311 262 SF 296312 262 SF 296313 294 SF 349314 262 SF 330315 261 SF 298316 261 SF 296317 272 SF 320LEVEL 4404 274 SF 319405 280 SF 316406 264 SF 300407 280 SF 316408 271 SF 316409 261 SF 317410 263 SF 304411 263 SF 296412 263 SF 296413 297 SF 349414 279 SF 330415 261 SF 298416 262 SF 296417 273 SF 320LEVEL 5504 274 SF 319505 281 SF 316506 281 SF 316507 281 SF 316508 271 SF 317509 261 SF 304510 263 SF 296511 263 SF 296512 263 SF 296513 297 SF 349514 279 SF 330515 261 SF 298516 262 SF 296517 273 SF 320LEVEL 6604 274 SF 319605 281 SF 316606 281 SF 316607 281 SF 316608 271 SF 317609 261 SF 304610 263 SF 296611 263 SF 296612 262 SF 296613 297 SF 349614 278 SF 330615 260 SF 298616 263 SF 296617 273 SF 320LEVEL 7704 274 SF 319705 281 SF 316706 279 SF 316707 281 SF 316708 271 SF 317709 261 SF 304710 263 SF 296711 263 SF 296712 262 SF 296713 297 SF 349714 279 SF 330715 260 SF 298716 262 SF 296717 274 SF 320
274 SF
264 SF
1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
5
5
AA
BB
C C
D D
EE
F F
6
62
21
1
3
3
4
4
24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"
86' - 2"
19' -
1"
7' -
2"12
' - 1
0"6'
- 0"
17' -
2"
2" 48' - 3" 4' - 6" 3' - 9" 5' - 11" 23' - 5" 2"
7' -
6"5'
- 0"
1' -
11"
62' -
3"
0' -
2"35
' - 1
0"23
' - 2
"3'
- 1"
0' - 2"56' - 10" 5' - 7" 23' - 5" 0' - 2"
9' -
0"
8' - 5"8' - 3"
64' -
10"
0' -
2"
2' -
9"
4' -
10"
7' -
9"
11' -
6"
TRANSFORMEREXHAUST SHAFT
ELEVATOR SHAFT
BASE OFTRANSFORMEREXHAUST OPENINGAT 6" A.F.F.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.3S
115205.22.2013
AuthorChecker1152_TRIAD 12TH
SLAB PLAN - LEVEL 3
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"LEVELS 3-7 (TYPE V)1
A3.01
A3.0
A3.1
A3.1
1
2
2
1A4.0
1A4.0
2A4.0
2A4.0
R03CONTROL RM.
R04ELEV LOBBY
R00STAIR A
R01STAIR B
7' -
7"12
' - 2
"16
' - 8
"28
' - 1
0"
6' -
8 1/
2"9'
- 11
1/2
"
R05
MECH.ROOM
R02ELEV
86' - 2"
24' - 6" 24' - 2" 13' - 9" 23' - 9"
57' - 5" 5' - 3" 23' - 11"
65' -
3"
14' -
9"
23' -
9"
59' -
8"
189' - 4"T.O. PARAPETELEV.
189' - 4"T.O. PARAPETELEV.
26' - 9"
802801
800
A7.16
5
5
AA
BB
D D
F F
6
62
2
A7.27
1
1
3
3
4
4
2A-F
E
3A8.0
E2E2 E1E1
185' - 4"T.O.F.F.ELEV:
A5A5B8
GREEN ROOF
GREEN ROOF
RIDGE
VALLEY
VALL
EY
EXIT
TENANT ROOF DECK1626 SF
T.O. ROOF @ DRAINELEV: 184' - 4.5"
T.O. ROOF @HIGHEST POINTELEV: 185' - 0.5"
T.O. ROOF @HIGHEST POINTELEV: 184' - 11.25"
T.O. ROOF @HIGHEST POINTELEV: 184' - 10.25"
T.O. ROOF @ DRAINELEV: 184' - 4.5"
T.O. ROOF @HIGHEST POINT
ELEV: 184' - 10.25" T.O. PARAPETELEV:
T.O. ROOF @HIGHEST POINT
ELEV: 184' - 6"
1/4"
: 12
"1/
4" :
12" 1/4" : 12"
1/4" : 12"
1/4" : 12"
1/4"
: 12
"
E2
RID
GE
T
SA9.715
26' -
3"
18' -
10"
17' -
2"
7' - 2 3/4" 9' - 3" 10' - 3 1/4"
42" GUARD RAIL
42" GUARD RAIL
42" GUARD RAIL
189' - 4"
A3.03
A3.0
4
A3.1 3
A3.1
4
185' - 4"T.O. ROOF DECKELEV:
4A8.0
EXIT
A 3.1
1
A 3.0
A 3.0
A 3.1 2A5
A5
A
B
D
3
195' - 9"
T.O. ELEVATORELEV:
T.O. VESTIBULEELEV:
T.O. PARAPETELEV:
1/4 : 12"
1/4
: 12"
26' - 9"
7' - 2" 9' - 0" 10' - 7"
16' -
8"
6' -
8 1/
2"9'
- 11
1/2
"
A3.03
A3.0
4
A3.1 3
A3.1
4
1' - 0" 10' - 5"
11' - 5"
18' -
11
1/2"
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A2.4
115205.22.2013
SL, AMMG1152_TRIAD 12TH
FLOOR PLAN - ROOF
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"ROOF PLAN1
NORTH
SCALE: 1/8" = 1'-0"UPPER ROOF2
1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 5
155' - 9"
ELEV.LEVEL 6
164' - 11"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
11' -
3"
9' -
2"9'
- 2"
9' -
2"9'
- 2"
9' -
2"10
' - 0
"9'
- 2"
TYPE
VA
CO
NST
RU
CTI
ON
TYPE
1A
CO
NST
RU
CTI
ON
PLPL
203' - 5"
195' - 9"
T.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV:
13 1
311 11
7
8
7
202' - 11"
75' -
0"
8
2A
195' - 3"
9' -
2"
LOUVER FORMECHANICALVENTILATION
METAL GRATE COVER
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 5
155' - 9"
ELEV.LEVEL 6
164' - 11"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
11' -
3"
9' -
2"9'
- 2"
9' -
2"9'
- 2"
9' -
2"10
' - 0
"9'
- 2"
TYPE
VA
CO
NST
RU
CTI
ON
TYPE
1A
CO
NST
RU
CTI
ON
PL PLT.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV: 195' - 3"
195' - 9"
202' - 11"
203' - 5"
189' - 4"T.O. PARAPETELEV:1
6
7
7
7
7
6
8310
3
2A13
14
18
70' -
0" S
BC H
EIG
HT
LIM
IT
75' -
0" S
MC
HEI
GH
T LI
MIT
AWNING
11
2A
12
FIBER CEMENT PANEL
VERTICAL METAL PANELCOLOR: COOL METALLIC SILVER
NOT USED
CONCRETE
CONCRETE MASONRY UNIT - CMU
CAST-IN-PLACE CONCRETE PLANTER
VINYL DOOR SYSTEM - WHITE
VINYL WINDOW SYSTEM - WHITE
STOREFRONT SYSTEM - ALUMINUM
DECORATIVE METAL PANEL GUARDRAILPER DETAIL 2/A9.11
PATIO PRIVACY SCREEN
METAL FENCE OR SECURITY GATEPER PLAN
BOLT-ON JULIET BALCONY
EXHAUST LOUVER(PAINT TO MATCH ADJACENT SIDING)
AIR INTAKE VENT
ELEVATOR HOISTWAY VENT
TRANSFORMER ROOM EXHAUST VENT
FIRE DEPARTMENT CONNECTION
OVERFLOW SCUPPER
MATERIALS LIST:
1
2A
2B
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
SOUTH ELEVATION
10' TO LESS THAN 15'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
45% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
658
524
488
499 178
210
235
235 42%
45%
43%
36%
WALL OPENING AREA CALCULATIONS (SBD 705.8)
REQUIREMENTS BASED ON UNPROTECTED OPENINGS, SPRINKLERED
SOUTH ELEVATION
5' TO LESS THAN 10'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
25% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
308
235
256
131 0
8
8
8 3%
3%
3%
0%
SOUTH ELEVATION
15' TO LESS THAN 20'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
75% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
60
45
50
45 33
33
33
33 55%
73%
66%
73%
WALL OPENING AREA CALCULATIONS (SBD 705.8)
REQUIREMENTS BASED ON UNPROTECTED OPENINGS, SPRINKLERED
EAST ELEVATION
15' TO LESS THAN 20'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
75% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
808
617
661
227 70
405
313
313 39%
51%
61%
31%
ELEV.ROOF DECK
185' - 4"
203' - 5"
202' - 11"
195' - 9"
195' - 3"
T.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV:
2A
ELEV.ROOF DECK
185' - 4"
202' - 11"
203' - 5"
195' - 3"
195' - 9"
T.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV:
2A
OUTDOOR AIR INTAKE TO BE PROVIDED VIA WINDOWTRICKLE VENTS WITH A MINIMUM OF 4 SQUARE INCHESOF NET FREE AREA FOR EACH UNIT. IF A TRICKLEVENT IS NOT POSSIBLE IN THE UNIT WINDOW, THE GCSHALL COORDINATE WITH ARCHITECT FOR THROUGH-WALL VENT LOCATION. VENTILATION SHALL COMPLYWITH SMC 403.8.6.1.
ALL ENVIRONMENTAL AIR EXHAUSTS SHALL BE AMINIMUM OF 3'-0" FROM OPERABLE OPENINGS,INCLUDING TRICKLE VENTS, PER SMC 501.2.
VENTILATION + EXHAUST NOTES
1.
2.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A3.0
115205.22.2013
AMMG1152_TRIAD 12TH
ELEVATION - SOUTH+ EAST
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"EAST1
SCALE: 1/8" = 1'-0"SOUTH2
SCALE: 1/8" = 1'-0"ELEVATOR PENTHOUSE EAST3SCALE: 1/8" = 1'-0"
ELEVATOR PENTHOUSE SOUTH4 3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.135 BP CORRECTION 3 05.09.13
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 5
155' - 9"
ELEV.LEVEL 6
164' - 11"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
9' -
2"10
' - 0
"9'
- 2"
9' -
2"9'
- 2"
9' -
2"9'
- 2"
11' -
3"
TYPE
1A
CO
NST
RU
CTI
ON
TYPE
VA
CO
NST
RU
CTI
ON
PLPL195' - 3"
195' - 9"
202' - 11"
T.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV:
T.O. PARAPETELEV:
1
77
76
7
6 3
393
8
1
914
1213 132A 18
11
70' -
0" S
BC H
EIG
HT
LIM
IT
75' -
0" S
MC
HEI
GH
T LI
MIT
12
2A
TRANSFORMERAIR INTAKE VENT
9
203' - 5"
LOUVER FORMECHANICALVENTILATION
METAL GRATE COVER
9
A9.112
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 5
155' - 9"
ELEV.LEVEL 6
164' - 11"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
11' -
3"
9' -
2"9'
- 2"
9' -
2"9'
- 2"
9' -
2"10
' - 0
"9'
- 2"
TYPE
VA
CO
NST
RU
CTI
ON
TYPE
1A
CO
NST
RU
CTI
ON
PLPL
202' - 11"
203' - 5"
195' - 9"
189' - 4"
T.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV:
T.O. PARAPETELEV:
11
77
113
1818
75' -
0" L
OW
EST
FIR
E D
EPAR
TMEN
T A
CC
ESS
3
9
2A
TRANSFORMEREXHAUST VENT:CONCRETE SHAFTTERMINATES ATKITCHEN COUNTERON LEVEL 3 PERSHEETS A5.3 + A5.4
13
5A5.4
2A
3
2A
A9.112
WALL OPENING AREA CALCULATIONS (SBD 705.8)
REQUIREMENTS BASED ON UNPROTECTED OPENINGS, SPRINKLERED
WEST ELEVATION
0' TO LESS THAN 3'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
25% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
562
460
334
0 0
0
50
50 8%
11%
0%
0%
NORTH ELEVATION
10' TO LESS THAN 15'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
45% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
585
447
487
277 107
121
189
189 32%
42%
25%
39%
WALL OPENING AREA CALCULATIONS (SBD 705.8)
REQUIREMENTS BASED ON UNPROTECTED OPENINGS, SPRINKLERED
NORTH ELEVATION
5' TO LESS THAN 10'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
25% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
308
235
256
0 0
51
59
59 19%
25%
20%
0%
NORTH ELEVATION
15' TO LESS THAN 20'
LEVELS 7
LEVELS 1
LEVELS B1
FIRE SEPARATIONDISTANCE
GROSS WALLAREA (SF)
WINDOWAREA (SF)
PERCENTAGEOF WALL %
75% MAX. ALLOWABLE AREA PER LEVEL
LEVELS 2-6
51
42
50
0 0
24
31
31 61%
74%
48%
0%
FIBER CEMENT PANEL
VERTICAL METAL PANELCOLOR: COOL METALLIC SILVER
NOT USED
CONCRETE
CONCRETE MASONRY UNIT - CMU
CAST-IN-PLACE CONCRETE PLANTER
VINYL DOOR SYSTEM - WHITE
VINYL WINDOW SYSTEM - WHITE
STOREFRONT SYSTEM - ALUMINUM
DECORATIVE METAL PANEL GUARDRAILPER DETAIL 2/A9.11
PATIO PRIVACY SCREEN
METAL FENCE OR SECURITY GATEPER PLAN
BOLT-ON JULIET BALCONY
EXHAUST LOUVER(PAINT TO MATCH ADJACENT SIDING)
AIR INTAKE VENT
ELEVATOR HOISTWAY VENT
TRANSFORMER ROOM EXHAUST VENT
FIRE DEPARTMENT CONNECTION
OVERFLOW SCUPPER
MATERIALS LIST:
1
2A
2B
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
ELEV.ROOF DECK
185' - 4"
202' - 11"
T.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV: 195' - 3"
195' - 9"
203' - 5"
2A
ELEV.ROOF DECK
185' - 4"
T.O. PARAPETELEV:
T.O. PARAPETELEV:
T.O. PENTHOUSE ROOFELEV:
T.O. VESTIBULE ROOFELEV:
202' - 11"
203' - 5"
195' - 3"
195' - 9"
2A
OUTDOOR AIR INTAKE TO BE PROVIDED VIA WINDOWTRICKLE VENTS WITH A MINIMUM OF 4 SQUARE INCHESOF NET FREE AREA FOR EACH UNIT. IF A TRICKLEVENT IS NOT POSSIBLE IN THE UNIT WINDOW, THE GCSHALL COORDINATE WITH ARCHITECT FOR THROUGH-WALL VENT LOCATION. VENTILATION SHALL COMPLYWITH SMC 403.8.6.1.
ALL ENVIRONMENTAL AIR EXHAUSTS SHALL BE AMINIMUM OF 3'-0" FROM OPERABLE OPENINGS,INCLUDING TRICKLE VENTS, PER SMC 501.2.
VENTILATION + EXHAUST NOTES
1.
2.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A3.1
115205.22.2013
AMMG1152_TRIAD 12TH
ELEVATION - NORTH+ WEST
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"NORTH1 SCALE: 1/8" = 1'-0"
WEST2
SCALE: 1/8" = 1'-0"ELEVATOR PENTHOUSE NORTH4 SCALE: 1/8" = 1'-0"
ELEVATOR PENTHOUSE WEST3 3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.135 BP CORRECTION 3 05.09.13
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
9' -
2"9'
- 2"
9' -
2"9'
- 2"
9' -
2"10
' - 0
"9'
- 2"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 5
155' - 9"
ELEV.LEVEL 6
164' - 11"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
2A4.0
ELEV.AVG. GRADE
116' - 1 1/4"
STUDIO STUDIO
STUDIO
STUDIO STUDIO CORR. STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
LOBBY
STUDIO
CORR.
STUDIOSTUDIOSTUDIOSTUDIO
STUDIOSTUDIO
STUDIO STUDIO
CORR.
STUDIO STUDIO STUDIO STUDIOCORR.
CORR.STUDIOSTUDIOSTUDIOSTUDIOSTUDIO
STUDIO STUDIO STUDIO STUDIO STUDIO CORR.
CORR.STUDIOSTUDIOSTUDIOSTUDIOSTUDIO
STUDIOSTUDIO
STUDIO
STUDIO CORR.
189' - 4"T.O. PARAPETELEV:
T.O. PARAPETELEV:
195' - 3"
T.O. PENTHOUSE ROOFELEV:
203' - 5"T.O. PARAPETELEV:
202' - 11"
T.O. VESTIBULE ROOFELEV:
189' - 4"T.O. PARAPETELEV:
PL PL
CO
NST
RU
CTI
ON
TYPE
V(
A)C
ON
STR
UC
TIO
NTY
PE 1
A
ALLE
Y
12TH
AVE
NU
E
185' - 4"T.O. ROOF DECKELEV:
WINDOWWELL
75' -
0" S
MC
HEI
GH
T LI
MIT
70' -
0" S
BC H
EIG
HT
LIM
IT
STUDIO
STUDIO
STUDIO
STUDIO
F1
F1
F1
F1
F33 HR.
F3
F3
F6
E4
C2C1
A9.72
A9.71
A9.73
3' -
8"
3 HR. SEPARATIONPER SBC 509.2
R1 R2
A9.03
A9.01
A9.17
ELEV.ELEVATOR PIT
103' - 7"
A9.12
A9.11
A9.110
A9.111
A9.16
A9.15
F43 HR.
F4
F4
F33 HR.
F3
F3
195' - 9"
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
1A4.0
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 5
155' - 9"
ELEV.LEVEL 6
164' - 11"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
STUDIO CORR. STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
STUDIO
CORR.
CORR.
CORR.
CORR.
CORR.
CORR.
CORR.
189' - 4" 189' - 4"
195' - 9"
T.O. PARAPETELEV.
T.O. PARAPETELEV.
T.O. PARAPETELEV.
T.O. VESTIBULE ROOFELEV.
CO
NST
RU
CTI
ON
TYPE
1A
9' -
2"9'
- 2"
9' -
2"9'
- 2"
9' -
2"19
' - 2
"
PLPL
PATIO
7' SCREEN FENCE @PROPERTY LINE
7' SCREEN FENCE@ PROPERTY LINE
C1
F6 F6
F3
F3
F33 HR.
F1
F1
F1
F1
6' -
5"
LADDER PERSBC 1004.8
MECH.ROOM
3 HR. SEPARATIONPER SBC 509.2
185' - 4"T.O. ROOF DECKELEV:
195' - 3"
TENANT STORAGE
R2R1R1
A9.03
70' -
0" S
BC H
EIG
HT
LIM
IT
11' -
3"
75' -
0" S
MC
HEI
GH
T LI
MIT
F5
F3
A9.15
A9.16
A9.17
F33 HR.
F43 HR.
F4
F4
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A4.0
115205.22.2013
AMMG1152_TRIAD 12TH
SECTION - E/W + N/S
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/8" = 1'-0"EAST/WEST SECTION (LOOKING NORTH)1 SCALE: 1/8" = 1'-0"
NORTH/SOUTH (LOOKING WEST)2
1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
C
64
1A8.0
2A8.0
118LOBBY
120BATH
100
B1B4
C2
C2C2
5' - 9" 15' - 9" 8' - 0"
A5.04
101
3
103
104
105
102
A6.0
1A
119
CONCIERGEOFFICE
6' - 8"
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
USPS STD-4C NOTES:-EVERY UNIT NEEDS ITS OWN SEPARATE MAILBOX-ONE (1) PARCEL BOX IS REQUIRED PER TEN (10) MAILBOXES
55" O
VER
ALL
HEI
GH
T
54 1
/4" R
OU
GH
OPE
NIN
G
OPENING30 3/8" ROUGH
31 1/8" OVERALL WIDTH
BOX IS17" DEEP
CL
OF
USP
S LO
CK
36"-
48"
(PLAN) 17"
15"
MIN
B.O
.PA
RC
EL
4' -
7"1'
- 3"
5' -
10"
1' -
3"4'
- 7"
5' -
10"
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A5.0
115205.22.2013
SLMG1152_TRIAD 12TH
AMENITY PLAN
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"AMENITY1SCALE: 1/2" = 1'-0"
900 - Typical USPS STD-4C Mailbox2
SCALE: 1/4" = 1'-0"LOBBY MAILBOXES - WEST4 SCALE: 1/4" = 1'-0"
LOBBY MAILBOXES - SOUTH3
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
UP
UNIT WALL ASSEMBLIES TO BE TYPE A1 ONLEVELS 3-7 / OR B1 ON LEVELS 1-2 U.O.N.
SEE 'A2.X' SHEETS FOR ALL PARTY WALL,CORRIDOR, AND EXTERIOR WALL TYPES
WALL ASSEMBLIES TO BE METAL STUD ONLEVELS 1-2 U.O.N.
ROUTE EXHAUST VENTS IN JOIST CAVITY (TYP)OR IN SOFFIT WHERE INDICTATED.
SEE 'A2.X' SHEETS FOR WINDOW TAGS ANDDIMENSIONS NOT SHOWN
SEE 'A2.X' SHEETS FOR CORRIDOR DIMENSIONSAND UNIT ENTRY DOOR TAGS NOT SHOWN
ALL DUCTS TO BE ROUTED THROUGH ROOFTRUSSES AT LEVEL 7 CEILING. NO SOFFITREQUIRED.
GENERAL ENLARGED PLAN NOTES:
•
•
•
•
•
•
•
F
6
A
H
U1
U2
LIVING ROOM/BEDROOM
UNITENTRY
W/D
BATH
SD
WH
F
U4
CLOSET
KITC
HEN
A2/B2
6' - 0"
23' - 10"
12' -
11"
7' -
4"5'
- 7"
5' -
3"7'
- 8"
A6.14
*WIN
DO
W C
ON
DIT
ION
AT
LEVE
L 1*
A6.03
CPV
SV
PV
A9.115
2' -
9"
F
64
A
J
U1
U2UNIT
ENTRY
BATH
W/D
LIVING ROOM/BEDROOM
SD
WH
F
U4
CLOSET
B2
10' - 9"
2' -
9"
12' -
11"
5' -
6"7'
- 5"
18' - 4"
23' - 10"
5' -
3"7'
- 8"
*WINDOW CONDITION AT SOUTHEAST CORNER UNIT*
3' - 5"
*WIN
DO
W C
ON
DIT
ION
AT
SOU
THEA
ST C
OR
NER
UN
IT*
A6.03
A6.14
CPV
SV
PV
A9.114
D
5' -
8"7'
- 3"
*WIN
DO
W C
ON
DIT
ION
AT
LEVE
L B1
*
FA
*WINDOW CONDITION AT NORTHEAST CORNER UNIT*
4' - 1" 15' - 10" 3' - 10"
H
*WIN
DO
W C
ON
DIT
ION
AT
NO
RTH
EAST
CO
RN
ER U
NIT
*
8' -
3"4'
- 10
"
C
6
H
U1
U2 3' C
LR
SD
WH
F
1' -
8"
LIVING ROOM/BEDROOM
UNITENTRY
BATH
W/D
KITCHEN
CLOSET
U3
7' - 1" 4' - 5"
23' - 10"
13' -
1"
5' -
11"
7' -
2" A2/B2
11' - 6"
8' -
5"4'
- 8"
2' -
8"
A6.11
COLUMN LOCATIONSAT LEVEL 2
SOFFIT THIS AREA ATCONCRETE CEILING ONLY
A6.07
CPV
SV
PV
F
6
SD
WH
F
UNITENTRY
U1
W/DLIVING ROOM/
BEDROOM
BATH
CLOSET
KITC
HEN
U4U2
A2
23' - 10"
5' - 1" 5' - 0"
5' -
9"7'
- 2"
12' -
11"
7' -
8"5'
- 3"
2' -
8"
A6.14
A6.02
CPV
SV
PV
10' - 0"
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
6
J
COLUMN LOCATIONSAT LEVEL 2
A6.14
A6.02
CLOSETUNITENTRY
LIVING ROOM/BEDROOM
SD
BATH
KITC
HEN
U1
8' -
5"4'
- 8"
WH
F
23' - 10"
13' -
1"
CPV
SV
PV
W/D
1' -
8"
A2/B2U2
U4
5' - 1" 5' - 0"
6' -
1"7'
- 0"
10' - 1"
D
7' -
5"5'
- 8"
*WIN
DO
W C
ON
DIT
ION
AT
LEVE
L B1
*
C
6
U1
418
TELECOMCLOSET
23' - 10"
CLOSET
LIVING ROOM/BEDROOM
UNITENTRY
KITCHEN
W/D
BATH
WH
F
402
U2
U3
4' - 7" 9' - 5 1/2"
6' -
4 1/
2"2'
- 9"
13' -
1"
CPV
SV
PV
4' -
10"
8' -
3"
A2/B2
A2A6.0
2
A6.14
4' - 10" 6' - 6"
EXHAUST SOURCE SPECIFIC SYSTEM FORKITCHEN/LAUNDRY AREA VIA TENANTOPERATED 30-MINUTE TIMER
COMBINATION EXHAUST SYSTEM:
INTERMITTENT WHOLE HOUSE VENTILATIONVIA 24-HOUR TIMER, WITH SONE RATING OF 1.0OR LESS.
SOURCE SPECIFIC EXHAUST SYSTEM FORBATHROOM VIA TENANT OPERATED 30-MINUTETIMER
VENTILATION + EXHAUST LEGEND
NOTE: OUTDOOR AIR INTAKE SHALL BE PROVIDED VIAWINDOW TRICKLE VENTS WITH A MINIMUM OF 4 SQUAREINCHES OF NET FREE AREA PER EACH UNIT. IF ATRICKLE VENT IS NOT POSSIBLE IN THE UNIT WINDOW,THE GC SHALL COORDINATE WITH ARCHITECT FORTHROUGH WALL VENT LOCATION.
1.
2.
WHF
VENTILATION SYSTEMS SHALL COMPLY WITH SMC 403.8.1THROUGH 403.8.11.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A5.1
115205.22.2013
SLMG1152_TRIAD 12TH
UNIT PLANS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"UNIT A.3 - STUDIO3
SCALE: 1/4" = 1'-0"UNIT A.5 - STUDIO5
KEY PLAN - LEVEL B1
SCALE: 1/4" = 1'-0"UNIT A.1 - STUDIO1
SCALE: 1/4" = 1'-0"UNIT A.4 - STUDIO4
KEY PLAN - LEVELS 2-7 KEY PLAN - LEVEL 1 KEY PLAN - LEVELS 2-7
KEY PLAN - LEVEL B1 KEY PLAN - LEVEL 1
KEY PLAN - LEVELS 3-7KEY PLAN - LEVEL 2
KEY PLAN - LEVELS 1-3, 5-6
LEVELS 2-7UNIT #: 205, 305, 405, 505, 605,705
ACCESSIBILITY: TYPE A
316 GSF
LEVELS B1-7UNIT #: B07, 106, 107, 206-207, 306-307, 407, 506-507, 606-607, 707
ACCESSIBILITY: TYPE B
313 GSF @ B07316 GSF @ 107, 206-207, 306-307,407, 506-507, 606-607, 707324 GSF @ 106
LEVELS B1-1UNIT #: B08 + 108
ACCESSIBILITY: TYPE B
317 GSF
LEVELS 3-7UNIT #: 304, 308, 404, 408, 504, 508,604, 608, 704, 708
ACCESSIBILITY: TYPE B
317 GSF @ 308, 408, 508, 608, 708320 GSF @ 304, 404, 504, 604, 704
LEVELS 2UNIT #: 204 + 208
ACCESSIBILITY: TYPE B
317 GSF @ 208320 GSF @ 204
SCALE: 1/4" = 1'-0"UNIT A.2 - STUDIO2
KEY PLAN - LEVELS 4 + 7
LEVELS 4 + 7UNIT #: 406 + 706
ACCESSIBILITY: TYPE B
290 GSF
SCALE: 1/4" = 1'-0"UNIT A.6 - STUDIO6
UNIT WALL ASSEMBLIES TO BE TYPE A1 ONLEVELS 3-7 / OR B1 ON LEVELS 1-2 U.O.N.
SEE 'A2.X' SHEETS FOR ALL PARTY WALL,CORRIDOR, AND EXTERIOR WALL TYPES
WALL ASSEMBLIES TO BE METAL STUD ONLEVELS 1-2 U.O.N.
ROUTE EXHAUST VENTS IN JOIST CAVITY (TYP)OR IN SOFFIT WHERE INDICTATED.
SEE 'A2.X' SHEETS FOR WINDOW TAGS ANDDIMENSIONS NOT SHOWN
SEE 'A2.X' SHEETS FOR CORRIDOR DIMENSIONSAND UNIT ENTRY DOOR TAGS NOT SHOWN
ALL DUCTS TO BE ROUTED THROUGH ROOFTRUSSES AT LEVEL 7 CEILING. NO SOFFITREQUIRED.
GENERAL ENLARGED PLAN NOTES:
•
•
•
•
•
•
•
U1
SD
U2
K
CLO
SET
LIVING ROOM/BEDROOM
W/D
BATH
UNITENTRY
WHF
KITCHEN
U4
E2
A2/B2
10' - 10"
4' - 0 1/4" 6' - 9 3/4"
6' -
O"
7' - 3" 3' - 7"
A6.14
SOFFIT THISAREA ATCONCRETECEILING ONLY
A6.02
27' -
1"
9' -
8"
C
PV
SVPV
POSSIBLECOLUMNLOCATIONS.SEE SHEETSA2.0-A2.2S.
A
LU5
U1
CLO
SET
LIVING ROOM/BEDROOM
W/D
UNITENTRY
BATH
SD
WHF
KITCHEN
B6
11' - 6"
1' - 11" 5' - 10"
A6.14
U2
A2/B2
12' -
7 1
/2"
7' -
3 1/
2"
4' - 8" 6' - 10"A6.0
2
10"
10' -
2"
27' -
0"
4A5.4
C
PV
SVPV
U1
U2
K
BATH
CLO
SET
LIVING ROOM/BEDROOM
UNITENTRY
W/D
SD
WHF
KITCHEN
U4
A2/B2
6' -
O"
2' - 8"
6' - 9"
A6.14
SOFFIT THIS AREAAT CONCRETECEILING ONLY
A6.02
27' -
1"
3' - 10 1/2" 7' - 0 1/2"
10' - 11"
10' -
2"
C
PV
SVPV
F
C27' - 6" 3' - 4"
L
U5
C2
0' - 8" 5' - 10" 4' - 4"
B4
B6
20' -
7"
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
A
U1
K
WHF
COLUMN LOCATIONAT LEVELS 1-2
A6.14
A2/B2
W/D
KITCHEN
BATH
6' - 9 3/4" 4' - 0 1/4"
10' - 10"
5' -
8"
LIVING ROOM/BEDROOM
CLO
SET
UNITENTRY
U2
3' - 8" 7' - 2"
SD
A6.02
27' -
0"
C
PV
SVPV
6' - 7"
A
3
LU5
U1
U4
U2
CLO
SET
LIVING ROOM/BEDROOM
BATH
UNITENTRY
W/D
SD
WHF
KITCHEN
B2
5' -
8"
2' - 7"
4' - 2" 5' - 10" 1' - 9"
6' - 10" 4' - 11"
11' - 9"
A6.14
A6.02
27' -
0"
C
PV
SVPV
FURR W/ 2" RIGIDINSULATION AND 1LAYER OF 5/8" GWBTO IMPROVE UNITACOUSTICS NEARELEVATOR
A
3
U1
K
U4LIVING ROOM/
BEDROOM
BATH
CLO
SET
UNITENTRY
W/D
U2
SD
WHF
KITCHEN
B2
7' - 4" 4' - 5"
2' - 7"
5' -
8 1/
2"
6' - 10" 4' - 11"
11' - 9"
A6.14
A6.02
27' -
0"
C
PV
SVPV
EXHAUST SOURCE SPECIFIC SYSTEM FORKITCHEN/LAUNDRY AREA VIA TENANTOPERATED 30-MINUTE TIMER
COMBINATION EXHAUST SYSTEM:
INTERMITTENT WHOLE HOUSE VENTILATIONVIA 24-HOUR TIMER, WITH SONE RATING OF 1.0OR LESS.
SOURCE SPECIFIC EXHAUST SYSTEM FORBATHROOM VIA TENANT OPERATED 30-MINUTETIMER
VENTILATION + EXHAUST LEGEND
NOTE: OUTDOOR AIR INTAKE SHALL BE PROVIDED VIAWINDOW TRICKLE VENTS WITH A MINIMUM OF 4 SQUAREINCHES OF NET FREE AREA PER EACH UNIT. IF ATRICKLE VENT IS NOT POSSIBLE IN THE UNIT WINDOW,THE GC SHALL COORDINATE WITH ARCHITECT FORTHROUGH WALL VENT LOCATION.
1.
2.
WHF
VENTILATION SYSTEMS SHALL COMPLY WITH SMC 403.8.1THROUGH 403.8.11.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A5.2
115205.22.2013
SLMG1152_TRIAD 12TH
UNIT PLANS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"UNIT B.1 - STUDIO1 SCALE: 1/4" = 1'-0"
UNIT B.3 - STUDIO2
SCALE: 1/4" = 1'-0"UNIT B.4 - STUDIO3
KEY PLAN - LEVEL B1
KEY PLAN - LEVEL 1
KEY PLAN - LEVELS 2-7
KEY PLAN - LEVEL 1
KEY PLAN - LEVEL B1
KEY PLAN - LEVEL 1
KEY PLAN - LEVELS 2-7
LEVELS B1-7UNIT #: B10-B12, 110-112, 210-212, 310-312, 410-412, 510-512,610-612, 710-712
ACCESSIBILITY: TYPE B
297 GSF
LEVEL 1UNIT #: 115
ACCESSIBILITY: TYPE B
298 GSF
LEVELS B1-7UNIT #: B09, 109, 209, 309,409, 509, 609, 709
ACCESSIBILITY: TYPE B
304 GSF
SCALE: 1/4" = 1'-0"UNIT B.2 - STUDIO7
KEY PLAN - LEVELS 2-7
KEY PLAN - LEVEL 1
LEVELS 1-7UNIT #: 116, 215-216, 315-316, 415-416, 515-516,615-616, 715-716
ACCESSIBILITY: TYPE B
296 GSF (@ 116, 216, 316,416, 516, 616, 716)298 GSF (@ 115, 215, 315,415, 515, 615, 715)
KEY PLAN - LEVEL 1
KEY PLAN - LEVEL 2
KEY PLAN - LEVELS 3-7
LEVELS 1-2UNIT #: 117, 217
ACCESSIBILITY: TYPE B
320 GSF
LEVELS 3-7UNIT #: 317, 417, 517, 617,717
ACCESSIBILITY: TYPE B
320 GSF
SCALE: 1/4" = 1'-0"UNIT B.5 - STUDIO9 SCALE: 1/4" = 1'-0"
UNIT B.6 - STUDIO10
TILE SHOWERAT UNIT 115 ONLY.SEE PLUMBINGDRAWINGS FORSHOWER DRAINREQUIREMENTS.
U1
A
A
1
SD
K
LIVING ROOM/BEDROOM
BATH
UNITENTRY
W/D
WHF
KITC
HEN
CLOSET
4' - 3" 10' - 11"
15' - 2"
13' -
5"
11' - 0 1/2" 4' - 1 1/2"
15' - 2"
A6.12
A6.04
5A5.4
C
PV
SV
PV
3 HR. LIDOVERFRAMING ASNEEDED TO PROVIDEFOR CORRECTCOUNTERTOP HEIGHT
U1
D
1
SD
U2
K
UNITENTRY
BATH
LIVING ROOM/BEDROOM
CLO
SET
W/D
B
KITCHEN
U4
A2
13' - 8"
7' - 2 3/4"
13' - 8"
9' -
11 1
/4"
13' -
5"
5' -
2"8'
- 11
1/4
"
2' - 3 1/2"
4' - 3" 9' - 5"
WHF
A6.05
A6.14
27' -
1"
23' -
4"
4' -
11"
2' -
10"
C
PV
SVPV
D
1
B
SD
U1
U2
K
UNITENTRY
BATH
LIVING ROOM/BEDROOM
CLO
SET
W/D
WHF
U4
KITCHEN
B2
8' - 5" 5' - 3"
13' - 8"
7' - 4 3/4"
10' -
4 1
/2"
12' -
11
3/4"
5' -
6 1/
2"8'
- 9"
2' - 8 1/4"
4' - 3" 9' - 5"
A6.14
A6.05
23' -
4"
27' -
1"
4' -
11"
2' -
10"
C
PV
SVPV
D
1
SD
U2
U1
UNITENTRY
BATH
CLO
SET
LIVING ROOM/BEDROOM
W/D
WHF
U4
KITCHEN
B2
B6
13' - 8"
23' -
4"
10' -
5"
13' - 8"
7' - 10" 5' - 10"
5' -
1 1/
2"9'
- 0
1/2"
A6.14
A6.05
27' -
0 1
/2"
C
PV
SVPV
C2 U5LU5
1' - 3" 5' - 10" 6' - 7"
13' - 8"
UNIT WALL ASSEMBLIES TO BE TYPE A1 ONLEVELS 3-7 / OR B1 ON LEVELS 1-2 U.O.N.
SEE 'A2.X' SHEETS FOR ALL PARTY WALL,CORRIDOR, AND EXTERIOR WALL TYPES
WALL ASSEMBLIES TO BE METAL STUD ONLEVELS 1-2 U.O.N.
ROUTE EXHAUST VENTS IN JOIST CAVITY (TYP)OR IN SOFFIT WHERE INDICTATED.
SEE 'A2.X' SHEETS FOR WINDOW TAGS ANDDIMENSIONS NOT SHOWN
SEE 'A2.X' SHEETS FOR CORRIDOR DIMENSIONSAND UNIT ENTRY DOOR TAGS NOT SHOWN
ALL DUCTS TO BE ROUTED THROUGH ROOFTRUSSES AT LEVEL 7 CEILING. NO SOFFITREQUIRED.
GENERAL ENLARGED PLAN NOTES:
•
•
•
•
•
•
•
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
A
1
LIVING ROOM/BEDROOM
BATH
UNITENTRY
W/D
WHF
KITC
HEN
U1
U5
CLOSET
4' - 3" 10' - 11"
15' - 2"
4' -
1 1/
2"
5' - 1 1/2"
11' - 0 1/2"
15' - 2"
C
PV
SV
PV
A
B
1
5A5.4
A
K
*WIN
DO
W A
ND
EXH
AUST
SH
AFT
CO
ND
ITIO
N A
T LE
VEL
2*
--
6' -
10 1
/4"
6' -
8 1/
2"3'
- 1"
4' -
0"
EXHAUST SOURCE SPECIFIC SYSTEM FORKITCHEN/LAUNDRY AREA VIA TENANTOPERATED 30-MINUTE TIMER
COMBINATION EXHAUST SYSTEM:
INTERMITTENT WHOLE HOUSE VENTILATIONVIA 24-HOUR TIMER, WITH SONE RATING OF 1.0OR LESS.
SOURCE SPECIFIC EXHAUST SYSTEM FORBATHROOM VIA TENANT OPERATED 30-MINUTETIMER
VENTILATION + EXHAUST LEGEND
NOTE: OUTDOOR AIR INTAKE SHALL BE PROVIDED VIAWINDOW TRICKLE VENTS WITH A MINIMUM OF 4 SQUAREINCHES OF NET FREE AREA PER EACH UNIT. IF ATRICKLE VENT IS NOT POSSIBLE IN THE UNIT WINDOW,THE GC SHALL COORDINATE WITH ARCHITECT FORTHROUGH WALL VENT LOCATION.
1.
2.
WHF
VENTILATION SYSTEMS SHALL COMPLY WITH SMC 403.8.1THROUGH 403.8.11.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A5.3
115205.22.2013
SLMG1152_TRIAD 12TH
UNIT PLANS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"UNIT D.1 - STUDIO2
SCALE: 1/4" = 1'-0"UNIT C.3 - STUDIO3SCALE: 1/4" = 1'-0"
UNIT C.2 - STUDIO4
SCALE: 1/4" = 1'-0"UNIT C.1 - STUDIO5
KEY PLAN - LEVEL B1
KEY PLAN - LEVEL 1
KEY PLAN - LEVEL 2 KEY PLAN - LEVELS 3-7
KEY PLAN - LEVELS 3-7
LEVELS B1-1UNIT #: B13, 113
ACCESSIBILITY: TYPE B
347 GSF
LEVEL 2UNIT #: 213
ACCESSIBILITY: TYPE B
347 GSF
LEVEL 3-7UNIT #: 313, 413, 513, 613,713
ACCESSIBILITY: TYPE B
347 GSF
LEVELS 2-3UNIT #: 214, 314
ACCESSIBILITY: TYPE B
323 GSF
SCALE: 1/4" = 1'-0"UNIT D.2 - STUDIO1
LEVELS 4-7UNIT #: 414, 514, 614, 714
ACCESSIBILITY: TYPE B
327 GSF
KEY PLAN - LEVELS 4 - 72 + 3
A
21
B15
TRANSFORMER ACCESSWELL
012
009
C1C1
C1
24' - 6"
2A5.4
B16TRANSFORMER VAULT
3A5.4
17' - 5" 7' - 1"
12' -
0"
4' -
6"15
' - 7
"
28' -
3"
LOWERED CEILINGUNDER STAIR EXIT(ABOVE)
HATCH(ABOVE) FORTRANSFORMERINSTALLATION6'
- 0"
10' - 0"
5' - 0"
11' -
0"
19' -
7"
9' -
4"
6 R @ 6" EA4' - 7"
5 T @ 11" EA
SHAFT OPENINGABOVE
DN
011
2'x2'x2' SUMP WITHFLUSH MOUNTEDSTEEL GRATE COVER
6" REMOVABLECURB
FD
EXHAUST VENT INCEILING PERSBC 425.8.3.4
4A5.4
5A5.4
3' -
10"
R 3' - 8
"
106' - 1"T.O. SLABELEV:
6A5.4
INTAKE VENT INWALL W/ 3 HOUR
FIRE DAMPERPER SBC 425.8.3.3
R 3
' - 1
0"
AIR INTAKE SUPPLY FAN
3' -
10"
2' -
0"9'
- 9"
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.AVG. GRADE
116' - 1 1/4"
B15
TRANSFORMERACCESS WELL
11' -
7"
3A5.4
12' - 8"
34' - 0 1/4"
11' - 0" 5' - 3"
10' -
1"
8' -
7"6R
@ 6
" EA
3' -
0"
HATCH W/ LID FORTRANSFORMERINSTALLATION
B16TRANSFORMER VAULT
LOWERED CEILINGUNDER STAIR EXIT(BEHIND)
1' - 6"
TRANSFORMER ROOMELEV. 106' - 1"
R-30 RIGIDINSULATION
F5 F3
6A5.4
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.AVG. GRADE
116' - 1 1/4"
21
2A5.4
10' -
1"
11' -
7"
6' - 1"17' - 7"
23' - 8"
LOWEREDCEILINGUNDERSTAIR EXIT
4A5.4
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
A
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
1
3' -
0"
3 HR. LIDOVERFRAMING AS NEEDEDTO PROVIDE FOR CORRECTCOUNTERTOP HEIGHT
17"
SHAFT INTERIORDIMENSIONS: 17" x 21"
ELEV.LEVEL B1
109' - 1"
2
5T @ 11" EA4' - 0"4' - 4 1/2"
6R @
6" E
A3'
- 0"
A
B
1
4A5.4
5A5.4
114
REFUSE/RECYCLING
AREA
106
METALGATE
C4
C1C1
10' -
2"
17' -
2"
18' - 1"
8 CUBIC YARDDUMPSTER
8 CUBIC YARDDUMPSTER
TRANSFORMERACCESS HATCH
C1
17"
21"
SLO
PE:
1/8"
PER
FT.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A5.4
115205.22.2013
SLAM,MG1152_TRIAD 12TH
TRANSFORMERPLANS + SECTIONS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"TRANSFORMER ROOM PLAN1
SCALE: 1/4" = 1'-0"TRANSFORMER SECTION 22
SCALE: 1/4" = 1'-0"TRANSFORMER SECTION 13SCALE: 1/4" = 1'-0"
TRANSFORMER SECTION 34
SCALE: 1/4" = 1'-0"TRANSFORMER SECTION 45
SCALE: 1/4" = 1'-0"TRANSFORMER STAIR SECTION6
SCALE: 1/4" = 1'-0"RECYCLING/TRASH ROOM PLAN7
3 BP CORRECTION 02.28.13
IN TYPE-A UNITS, GRAB BARS ARE NOT REQUIRED TOBE INSTALLED WHERE REINFORCEMENT IS PROVIDEDFOR THE FUTURE INSTALLATION OF GRAB BARS &SHOWER SEATS AT WATER CLOSETS, BATHTUBS &SHOWERS; PER ICC/ANSI A117.7-2003, 1003.11.4.
IN TYPE-A UNITS, REAR GRAB BARS MAY BE 24" MIN. INLENGTH CENTERED ON THE TOILET WHEN THERE ISNO ROOM FOR A 36" GRAB BAR: PER ICC ANSI A117.7-2003 604.5.2.
DIMENSIONS @ GRAB BAR LOCATIONS ARE TOCENTERLINE OF REQ'D GRAB BARS; ADD ANADDITIONAL 2" @ TOP, SIDES AND BOTTOM FORBLOCKING SIZES.
CABINETRY IS PERMITTED UNDER WORK SURFACE &SINK WHEN CABINETRY CAN BE REMOVED WITHOUTREMOVAL OR REPLACEMENT OF THE WORK SURFACEOR SINK, FLOOR FINISH EXTENDS UNDER CABINETRYAND WALLS BEHIND, AND SURROUNDING CABINETRYARE FINISHED. PROVIDE A 30"x48" CLEAR FLOORSPACE POSITIONED FOR A FORWARD APPROACHWHEN BASE CABINETRY IS REMOVED.
WHEN BASE CABINETS ARE TO BE REMOVED @LOWERED WORK SURFACE AND SINKS, KNEE & TOECLEARANCES SHALL BE PROVIDED.
TYPICAL TYPE-A BATHROOM NOTES:
41"
18"
36"36"
MAX
18"15"
12" 12"
24"10" 46" MIN BLKG
GR
AB B
ARS
33"-
36"
3" 30"
3"
17"
LIGHT FIXTURECENTERED
OVER MIRROR
INSULATE HOTWATER SUPPLY
AND DRAIN
ADJUSTABLE HAND-HELD SHOWER ONA VERTICAL BAR
PROVIDE REMOVABLE SEATFOR SHOWER; PROVIDE
BLKG FOR SHOWER SEATPER ANSI 608.4.1
BLOCKING FORSHOWER SEAT PER
ICC/ANSI A117.1-2003SECTION 608.3.2
REMOVABLEBASE CABINETPER ICC/ANSI-2003 SECTION
1003.11.5’ 34"
27" M
IN
½” MAXTHRESHOLD @
STANDARDROLL-IN TYPE
SHOWER
BOTTOM EDGEOF REFLECTING
SURFACE OFMIRROR 40"
MAX A.F.F
18" 18"
WHERE SWING UP BARS AREINSTALLED, A CLEARANCE OF18" MIN FROM THE CL OFWATER CLOSET TO ANY SIDEOR OBSTRUCTION SHALL BEPROVIDED PER ICC/ANSIA117.1-2003 SECTION 604.5.3
15 3/4"
CL OF GRAB BAR 15 3/4"FROM CL OF WATERCLOSET
GRAB BAR SHALL BE 28" MININ LENGTH, MEASUREDFROM THE WALL TO THEEND OF HORIZONTALPORTION OF GRAB BAR
MIN28"
CLEAR
60"
MAX12"
MIN
24"
MAX
24"
27" BLKG
BLKG15" MIN
BLOCKING
48"
38" M
IN
MAX6"
16"
GR
A B B
AR
33"-
36"
9"6"
CONTROL END WALLBACK WALL HEAD END WALL
GR
AB B
AR
33"-
36"
32" M
AX
38" M
IN12"
32" M
AXG
RA B
BAR
S
33"-
36"
38" M
IN
3"-6
"
MIN18"
4"
6"
BLKG22"
28" BLKG
GRABBAR
32" M
AX
GR
A B B
AR
33"-
36"
38" M
IN
GRAB BAR
42"
32" M
AX
38" M
IN
42" SIDE WALL GRAB BAR 24" REAR WALL GRAB BAR 24" REAR WALL GRAB BAR
12"
36"
40" MIN BLKG
GRABBAR
32" M
AX
GR
A B B
AR
33"-
36"
38" M
IN
9" M
IN
27" M
IN
34" M
AX
KNEE
SPAC E
8" MINKNEE
SPACE
KNEE/TOE CLEARANCE REQUIREMENTS:
30" M
IN
25" MAX
6" 11"MIN
KNEESPACE
1.
2.
3.
4.
5.
W/D
PROVIDE BLOCKINGFOR SHOWER GRABBARS PER SECTION608.3.2 @ RESIDENTIAL
PROVIDE BLOCKING FORTOILET, PER DETAILS, @WALLS BEHIND AND TOTHE SIDE OF TOILET' @RESIDENTIAL
CLEAR FLOOR SPACE @LAVATORY, CENTEREDON FIXTURE (AT LEAST24" FROM WALL)
CLEAR FLOORSPACE @ TOILETCLEAR FLOORSPACE @ SHOWERA6.02A
2B
2C7' -
4"
4' -
3"
7' - 6"
3' -
8"
10' - 9"
W/D
A6.0 2C2A
2B
PROVIDE BLOCKING FOR SHOWERGRAB BARS PER SECTION 608.3.2 @RESIDENTIAL
PROVIDE BLOCKING FOR TOILET, PERDETAILS, @ WALLS BEHIND AND TOTHE SIDE OF TOILET' @ RESIDENTIAL
CLEAR FLOOR SPACE @ LAVATORY,CENTERED ON FIXTURE (AT LEAST24" FROM WALL)
CLEAR FLOOR SPACE @ TOILET
CLEAR FLOOR SPACE @ SHOWER
U2
6' -
11"
3' -
8"1'
- 5"
1' -
6"
10' - 0"
3' - 8"
6' - 4"
A
U2
W/D
PROVIDE BLOCKINGFOR SHOWER GRABBARS PER SECTION608.3.2 @ RESIDENTIAL
PROVIDE BLOCKING FORTOILET, PER DETAILS, @WALLS BEHIND AND TOTHE SIDE OF TOILET' @RESIDENTIAL
CLEAR FLOOR SPACE @LAVATORY, CENTEREDON FIXTURE (AT LEAST24" FROM WALL)
CLEAR FLOORSPACE @ TOILET
CLEAR FLOORSPACE @ SHOWER
7' - 2"
4' -
7"2'
- 9"
A6.0
2B
2C2A7' -
4"
3' -
8"
10' - 7"
U2
W/D
PROVIDE BLOCKINGFOR SHOWER GRABBARS PER SECTION608.3.2 @ RESIDENTIAL
PROVIDE BLOCKING FORTOILET, PER DETAILS, @WALLS BEHIND AND TOTHE SIDE OF TOILET' @RESIDENTIAL
CLEAR FLOOR SPACE @LAVATORY, CENTEREDON FIXTURE (AT LEAST24" FROM WALL)
CLEAR FLOORSPACE @ TOILET
CLEAR FLOORSPACE @ SHOWER
A6.02A
2B
2C
7' - 10"
7' -
6"
10' -
5"
5' - 0"
U2
W/D
PROVIDE BLOCKING FORSHOWER GRAB BARS PERSECTION 608.3.2 @ RESIDENTIAL
PROVIDE BLOCKING FORTOILET, PER DETAILS, @ WALLSBEHIND AND TO THE SIDE OFTOILET' @ RESIDENTIAL
CLEAR FLOOR SPACE @LAVATORY, CENTERED ONFIXTURE (AT LEAST 24"FROM WALL)
CLEAR FLOORSPACE @ TOILET
CLEAR FLOORSPACE @ SHOWER
60" DIAMETERTURNING SPACE
7' - 7" 3' - 3"10' - 10"
4' -
5"
A6.02A
2B
2C
7' -
2"
3' -
8 3/
8"
1' - 0"
7' -
6"
LIGHT FIXTURECENTEREDOVER MIRROR
2' -
10"
P-2 ACCENTPAINT
ADJUSTABLE HAND-HELD SHOWER ON A
VERTICAL BAR
A6.02A
2B
2CPROVIDE BLOCKINGFOR SHOWER GRABBARS PER SECTION608.3.2 @ RESIDENTIAL
PROVIDE BLOCKING FORTOILET, PER DETAILS, @WALLS BEHIND AND TOTHE SIDE OF TOILET' @RESIDENTIAL
CLEAR FLOOR SPACE @LAVATORY, CENTEREDON FIXTURE (AT LEAST24" FROM WALL)
CLEAR FLOORSPACE @ TOILET
CLEAR FLOORSPACE @ SHOWER
9' - 11"
7' -
0"
6' - 6"
3' -
4"
4' -
0"
C
120BATH
B1
CLEAR FLOORSPACE @ TOILET
5' DIAMETERTURNING SPACE
CLEAR FLOOR SPACE @LAVATORY, CENTEREDON FIXTURE (AT LEAST24" FROM WALL)
103
1' -
5"7'
- 5"
1' - 5" 6' - 11" 4' - 1"
8' - 4"1' - 4 3/4"
A6.0
1A
7' -
6"
A CLEAR FLOOR SPACE, POSITIONED FORPARALLEL APPROACH, AND CENTERED ONTHE LAVATORY SHALL BE PROVIDED PERICC/ANSI A117.1-2003 1004.11.3.1.1.
PROVIDE REINFORCING BLOCKING FORFUTURE INSTALLATION OF SHOWER SEAT,PER ICC/ANSI A117.1-2003 1004.11.3.2.
TYPICAL TYPE-B BATHROOM NOTES:
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A6.0
115205.22.2013
SLMG1152_TRIAD 12TH
INTERIORELEVATIONS(BATHROOMS)
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"UNIT BATH LAYOUT - C4
SCALE: 1/4" = 1'-0"UNIT BATH LAYOUT - A2
SCALE: 1/4" = 1'-0"UNIT BATH LAYOUT - B3
SCALE: 1/4" = 1'-0"UNIT BATH LAYOUT - D5 SCALE: 1/4" = 1'-0"
UNIT BATH LAYOUT - F - TYPE A7
ELEVATION 5A ELEVATION 5B ELEVATION 5C
SCALE: 1/4" = 1'-0"UNIT BATH LAYOUT - E6
SCALE: 1/4" = 1'-0"PUBLIC RESTOOM - LOBBY1
ELEVATION 1A
CABINETRY IS PERMITTED UNDER A WORKSURFACE OR SINK WHEN THE CABINETRYCAN BE REMOVED WITHOUT THE REMOVALOR REPLACEMENT OF THE WORK SURFACEOR SINK, THE FLOOR FINISH EXTENDSUNDER THE CABINETRY, & THE WALLSBEHIND & SURROUNDING THE CABINETRYARE FINISHED PER ANSI A117.1-20031003.12.3.1 & 1003.12.4.1.
WHEN BASE CABINETS ARE TO BE REMOVED@ LOWERED WORK SURFACE AND SINKS,KNEE & TOE CLEARANCES SHALL BEPROVIDED.
A 30"x48" CLEAR FLOOR SPACE POSITIONEDFOR A PARALLEL OR FORWARD APPROACHSHALL BE PROVIDED @ EACH APPLIANCE,PER ANSI A117.1-2003 1003.13.6.2.
THE FRONT OF THE SINK SHALL BE 34" MAX.A.F.F., AND A 30" x48" CLEAR FLOOR SPACE,POSITIONED FOR A FORWARD APPROACH,SHALL BE PROVIDED, PER ANSI A117.1-20031003.12.4.2 & 1003.12.4.1.
TYPICAL TYPE-A KITCHEN NOTES:
A6.12A
CLEAR FLOOR SPACEPOSITIONED FOR APARALLEL ORFORWARD APPROACH@ EACH APPLIANCE;CENTERED ONAPPLIANCE
COUNTERTOP TO EXTENDOVER 3 HR. CONCRETESHAFT LID OVERFRAME ASNEEDED TO PROVIDE FORCORRECT COUNTERTOPHEIGHT
A6.13A
CLEAR FLOOR SPACEPOSITIONED FOR APARALLEL ORFORWARD APPROACH@ EACH APPLIANCE;CENTERED ONAPPLIANCE
A6.14A
6' -
6"
CLEAR FLOORSPACE POSITIONEDFOR A PARALLEL ORFORWARDAPPROACH @ EACHAPPLIANCE;CENTERED ONAPPLIANCE
A6.1
1A
8' - 6"
MIN. 30" WIDE LOWEREDWORK AREA; 34" HIGH MAX
CLEAR FLOOR SPACEPOSITIONED FOR A PARALLELOR FORWARD APPROACH @EACH APPLIANCE; CENTEREDON APPLIANCE
3' -
0"1'
- 8"
2' -
10"
2' -
10"
6' - 0"
12"
12"
8' - 6"
34" M
AX.
LOWERED SINKAND WORK AREA
REMOVABLE BASECABINET PERMITTEDPER ICC/ANSI-2003SECTION 1003.12.3.1
UPPER CABINETS
REF.
DRAWER STACK
4" BACKSPLASH
2' - 6"2' - 6"
2' -
0"
2' - 6"2' - 6"2' - 6"
ELEVATION 1A
OPENSHELVING
REF.BASE
CABINETS
UPPERCABINETS
4" BACKSPLASH
ELEVATION 2A
OPENSHELVING
UPPERCABINETS
REF.
BASECABINETS
4" BACKSPLASH
1' -
6"3'
- 0"
2' - 6" 1' - 0"
2' - 6" 1' - 6"12"
ELEVATION 3A
6' - 6"
OPENSHELVING
REF.
BASECABINETS
UPPERCABINETS
4" BACKSPLASH
3' -
0"1'
- 6"
3' -
0"
2' -
0"
1' - 6" 1' - 6" 12" 2' - 6"
1' - 6" 1' - 6" 12"
4' - 0"
ELEVATION 4A
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A6.1
115205.22.2013
AuthorChecker1152_TRIAD 12TH
INTERIORELEVATIONS(KITCHENS)
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"UNIT KITCHEN LAYOUT - B2
SCALE: 1/4" = 1'-0"UNIT KITCHEN LAYOUT - C3 SCALE: 1/4" = 1'-0"
UNIT KITCHEN LAYOUT - D4
SCALE: 1/4" = 1'-0"UNIT KITCHEN LAYOUT - A - TYPE A1
SBC SECTION 3022 AND ASME SECTIONS 2.7 AND 2.8, PIPES, DUCTS, CONDUITS, ANDEQUIPMENT NOT USED FOR THE OPERATION OF THE ELEVATORS ARE PROHIBITED INMACHINE ROOM AND HOISTWAYS.
SBC 3020.4 MAINTAIN ALL REQUIRED WORKING CLEARANCES IN MACHINE ROOM.
ASME RULE 2.2.2. WATERPROOF AS NECESSARY TO PREVENT ENTRY OF GROUNDWATER. SUMP PUMPS MAY BE INSTALLED FOR FLOOD CONTROL BUT NOT APPROVED TOMAINTAIN A DRY PIT.
SBC 3023, ASME RULE 2.2.4. PROVIDE PIT LADDER.
ASME RULE 2.7.5.2. PROVIDE MACHINE ROOM VENTILATION.
SBC 3016.5. PROVIDE HOISTWAY VENTILATION. PROVIDE MOTORIZED DAMPERS ASREQUIRED BY SEATTLE ENERGY CODE 1412.4.1 FOR ALL HOISTWAY VENTS.
SBC 3016.3. COMPLY WITH SEISMIC REQUIREMENTS.
ASME RULE 2.7.4. PROVIDE 7'-0" CLEAR HEADROOM IN MACHINE ROOM.
SBC 3016.4. AND CHAPTER 11; ACCOMMODATE PEOPLE WITH DISABILITIES.
ASME SECTION 2.4 AND 3.4. PROVIDE PROPER TOP CAR RUNBYS, CLEARANCES ANDREFUGE SPACE.
ASME RULE 2.1.1.2 AND 2.11.14. GROUT ALL MASONRY JAMBS AND HEADERS TO RETAINFIRE RATING OF HOISTWAY. IN OTHER THAN MASONRY, PROVIDE LABELED ENTRANCEASSEMBLIES INSTALLED AS TESTED.
SBC 3020. GROUT BEHIND ALL HOISTWAY PENETRATIONS FOR PIPES, FIXTURES, ETC.
SBC 3016.5 ELEVATOR HOISTWAYS SHALL NOT BE VENTED OR PRESSURIZED THROUGHELEVATOR MACHINE ROOMS.
SBC 3016.5.4 VENTILATION AND PRESSURIZATION EQUIPMENT, DUCTS, ETC. CANNOT BELOCATED IN ELEVATOR MACHINE ROOMS, HOISTWAYS, OR SPACES.
ASME RULES 2.1.1.2 AND 2.14.1.8 GLASS USED IN OR ON ELEVATOR HOISTWAYS ANDCARS MUST BE LAMINATED AND MEET THE REQUIREMENTS OF ASME 297.1.
SBC 106 PROVIDE CALCULATIONS AND DRAWINGS TO DPD FOR APPROVAL OF THESTRESSES AS NOTED IN THE APPLICABLE RULES OF ASME SECTION 2.9.
ASME SECTION 2.6. PROVIDE CALCULATIONS TO DPD FOR APPROVAL OF THE ABILITY OFTHE PIT FLOOR AND STRUCTURE TO WITHSTAND THE ELEVATOR BUFFER ENGAGEMENTREACTIONS.
ASME 2.27.1. PROVIDE MEANS OF TWO-WAY CONVERSATION BETWEEN EACH ELEVATORAND A READILY ACCESSIBLE POINT (MAIN ELEVATOR LOBBY) OUTSIDE THE HOISTWAY.
ASME 2.27.1.1.2 THIS STRUCTURE IS CONSIDERED AS UNATTENDED, AND AN ADDITIONALEMERGENCY SIGNALING DEVICES SHALL BE PROVIDED (PHONE TO ANSWERINGSERVICE).
ASME 2.27.1.1.5 PROVIDE AN EMERGENCY POWER SUPPLY FOR THE DEVICES REQUIREDBY 2.27.1 THE SUPPLY SHALL BE CAPABLE OF OPERATING THE AUDIBLE DEVICE FOR ATLEAST ONE HOUR AND THE MEANS OF A TWO-WAY CONVERSATION FOR AT LEAST FOURHOURS.
SBC 3016.9. INSTALL APPROVED KEY RETAINER BOX, KEYED TO THE SECURE CITY KEY.
SBC 3016.10 KEYS REQUIRED FOR THE OPERATION OF ELEVATOR, FIRE EMERGENCYSERVICE, THE MACHINE ROOM AND THE MECHANICAL HOISTWAY ACCESS KEY SHALL BETAGGED AND KEPT IN THE KEY BOX.
COMPLY WITH APPLICABLE CODES.
PASSENGER ELEVATORS SHALL BE ACCESSIBLE AND COMPLY WITH ICC 117.1, CHAPTER296-96 OF THE WASHINGTON ADMINISTRATIVE CODE AND SBC CHAPTER 30. SBC 1109.6.
THE INSTALLATION OF PIPES, DUCTS, CONDUITS, WIRING, AND THE STORAGE OFMATERIALS NOT REQUIRED FOR THE OPERATION OF THE ELEVATOR ARE PROHIBITED INMACHINE ROOMS AND HOISTWAYS. SBC 3010.1. & SBC 3022
ALL NEW ELEVATORS AND THEIR INSTALLATION SHALL CONFORM WITH ASME A17.1 ASAMENDED IN SBC SECTION 3016 AND REQUIREMENTS OF SBC SECTIONS 3017, 3018 AND3019.
ELEVATOR HOISTWAY ENCLOSURES SHALL BE CONSTRUCTED AS SHAFT ENCLOSURESWITH A FIRE-RESISTANCE RATING OF 2 HOURS. SHAFT ENCLOSURES SHALL BECONSTRUCTED AS FIRE BARRIERS IN ACCORDANCE WITH SBC SECTION 706. SBC 707
ELEVATOR INSTALLATIONS SHALL COMPLY WITH ASME A17.1 SECTION 8.4 FOR SEISMICCONSIDERATIONS. THE PROVISIONS FOR SEISMIC ZONE 3 SHALL APPLY. SBC 3016.3.
THIS PROJECT IS NOT GROUP I-3 OCCUPANCY, IT DOES NOT HAVE OCCUPIED FLOORSHIGHER THAN 75' ABOVE THE LOWEST LEVEL OF FIRE DEPATRMENT ACCESS, AND IT ISEQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM COMPLYING WITHSBC 903.3.1.1. THEREFORE ELEVATOR LOBBIES ARE NOT REQUIRED PER SBC707.17.1EXCEPTION 4. THE PROJECT IS NOT USING PRESSURIZATION IN LIEU OF LOBBIES,BECAUSE LOBBIES ARE NOT REQUIRED.
NOT USED
AT LEAST ONE ELEVATOR CAR SHALL BE SIZED TO ACCOMMODATE A 24"x84"AMBULANCE STRETCHER IN THE HORIZONTAL, OPEN POSITION. SBC 3016.12. THE SAMECAR SHALL BE SUPPLIED WITH POWER FROM A LEGALLY REQUIRED STANDBY OREMERGENCY SYSTEM.
ELEVATOR CONTROLS AND MACHINERY OTHER THAN DRIVING MACHINES ANDGOVERNORS SHALL BE LOCATED IN A ROOM DEDICATED EXCLUSIVELY TO ELEVATOREQUIPMENT. ELEVATOR EQUIPMENT AND MACHINE ROOMS SHALL BE ENCLOSED BYFIRE BARRIERS WITH A 1 HOUR RATING. SBC 3020.2. ELEVATOR MACHINE ROOMPROTECTION SHALL BE IN ACCORDANCE WITH DPD DIRECTOR'S RULE 21-97.
PROVIDE WORKING CLEARANCES INSIDE THE EQUIPMENT OR MACHINERY ROOM ASSPECIFIED IN SBC SECTION 3020.4.
PROVIDE A FIXED VERTICAL LADDER OF NON-COMBUSTIBLE MATERIAL IN EACHELEVATOR PIT. THE RUNGS, STEPS, OR CLEATS SHALL BE AT LEAST 16" WIDE. THENEAREST POINT OF THE LADDER SHALL BE WITHIN 39" HORIZONTALLY FROM THE MEANSTO UNLOCK THE EGRESS DOOR FROM THE PIT. THE PIT SHALL ONLY BE ACCESSIBLE TOELEVATOR PERSONNEL. SBC 3023.1. & ASME 2.2.4.2 & 2.2.4.3
PROVIDE A SUMP PUMP IN THE ELEVATOR PIT PER CITY OF SEATTLE REQUIREMENTS.
THE ELEVATOR SHALL BE AN ACCESSIBLE MEANS OF EGRESS COMPLYING WITH SBCSECTION 1007.4. SBC 1007.21.
ELEVATORS SHALL COMPLY WITH THE EMERGENCY OPERATION AND SIGNALING DEVICEREQUIREMENTS OF SECTION 2.27 OF ASME A17.1. A LEGALLY REQUIRED STANDBYPOWER SYSTEM SHALL BE PROVIDED FOR OPERATION OF THE ELEVATOR, THE SHUNTTRIP, AND ELEVATOR CAR LIGHTING IN ACCORDANCE WITH SBC CHAPTER 27 AND THESEATTLE ELECTRIAL CODE.
PROVIDE A TWO-WAY COMMUNICATION SYSTEM PER SBC 1007.8.1.
ELEVATOR NOTES
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
17)
18)
19)
20)
21)
22)
23)
24)
25)
26)
27)
28)
29)
30)
31)
32)
33)
34)
35)
36)
37)
38)
STAIR TREADS AND RISERS, STAIR RISER HEIGHTS SHALL BE 7 INCHES MAXIMUMAND 4 INCHES MINIMUM. STAIR TREAD DEPTHS SHALL BE 11 INCHES MINIMUM.STAIRS WITHIN AN INDIVIDUAL DWELLING UNIT MAY HAVE A MAXIMUM RISERHEIGHT OF 7.75 INCHES AND A MINIMUM TREAD DEPTH OF 10 INCHES SBC 1009.4.
DIMENSIONAL UNIFORMITY, STAIR TREADS AND RISERS SHALL BE OF UNIFORMSIZE AND SHAPE. THE TOLERANCE BETWEEN THE LARGEST AND SMALLESTRISER OR BETWEEN THE LARGEST AND SMALLEST TREAD SHALL NOT EXCEED0.375 INCH IN ANY FLIGHT OF STAIRS. SBC 1009.4.4.
STAIRWAY WIDTH. THE WIDTH OF STAIRWAYS SHALL NOT BE LESS THAN 44INCHES. SBC 1009.1.
HEADROOM. STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCE OF 80INCHES MEASURED VERTICALLY FROM A LINE CONNECTING THE EDGE OF THENOSINGS. SBC 1009.2.
HANDRAILS. STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE. HANDRAILSSHALL BE OF A UNIFORM HEIGHT BETWEEN 34" AND 38" ABOVE THE STIAR-TREAD NOSING. HANDRAILS SHALL BE CONTINUOUS SBC 009.12 & SBC 1012.4.
HANDRAIL EXTENSIONS. HANDRAILS SHALL BE CONTINUOUS BETWEEN FLIGHTS,OR THEY SHALL RETURN TO A WALL OR THE WALKING SURFACE. AT THE TOP OFA STAIRWAY, HANDRAILS MUST EXTEND HORIZONTALLY 12 INCHES BEYOND THETOP RISER. AT THE BOTTOM OF A STAIRWAY, HANDRAILS MUST CONTINUE TOSLOPE FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. REFER TOSTAIR PLANS AND DETAILS. SBC 1012.6.
HANDRAIL PROFILES. HANDRAILS ARE TO BE GRASPABLE, WITH A DIAMETERBETWEEN 1 1/4" AND 2". IF THE HANDRAIL IS NOT CIRCULAR IN CROSS SECTION,A SHAPE WITH EQUIVALENT GRASPABILITY SHALL BE PROVIDED. CLEAR SPACEBETWEEN A HANDRAIL AND A WALL SHALL BE 1 1/2" MINIMUM. REFER TO STAIRDETAILS. SBC 1012.3 & 1012.7.
HANDRAIL ASSEMBLIES AND GUARDS SHALL BE DESIGNED AND CONSTRUCTEDTO THE STRUCTURAL LOADING CONDITIONS SET FORTH IN SBC 1607.7.
IN STAIRWAYS THAT CONTINUE BELOW THE LEVEL OF EXIT DISCHARGE, ANAPPROVED BARRIER SHALL BE PROVIDED AT THE LEVEL OF EXIT DISCHARGETO PREVENT PERSONS FROM UNINTENTIONALLY CONTINUING TO LEVELSBELOW. REFER TO STAIR DETAILS. SBC 1022.7.
STAIRWAY SIGNAGE SHALL BE PROVIDED AT EACH FLOOR LANDING IN INTERIORVERTICAL EXIT ENCLOSURES. THE SIGN SHALL DESIGNATE THE FLOOR LEVEL,THE TERMINUS OF THE TOP AND BOTTOM OF THE STAIR ENCLOSURE, THEIDENTIFICATION OF THE STAIR, THE STORY AND DIRECTION TO THE EXITDISCHARGE, WHETHER THERE IS ROOF ACCESS FROM THE STAIRWAY FOR THEFIRE DEPARTMENT, AND WHETHER THE ROOF IS ACCESSED BY ROOF HATCH.THE SIGN SHALL BE LOCATED 5 FEET ABOVE THE FLOOR LANDING AND BEREADILY VISIBLE WHEN THE DOORS ARE IN BOTH OPEN AND CLOSEDPOSITIONS. REFER TO STAIR DETAILS. SBC 1022.8.
REFER TO EGRESS NOTES, SHEET A0.02 FOR ADDITIONL REQUIREMENTSREGARDING EXIT ENCLOSURES, EXIT SIGNAGE, EXIT LIGHTING, GUARDS, ANDGENERAL MEANS OF EGRESS NOTES.
STAIR NOTES
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
F
4
2A7.0
9 T @ 11" EA10 R @ 6.67" EA
8' - 3"
UP
3' -
9"
1' -
6"
11 1/2"
11"
3A7.0
ELEV.LEVEL B1
109' - 1"
4
9 T @ 11" EA
114' - 9"
115' - 6"
T.O. STAIRELEV:
3A7.0
T.O. WALLELEV:
10 R @ 7" EA9' - 2"
ELEV.LEVEL B1
109' - 1"
F2
A7.018"
BICYCLE RUNNEL
4A7.0
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.AVG. GRADE
116' - 1 1/4"
3A7.0
5' -
0"
BIKE RUNNEL
31°
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A7.0
115205.22.2013
SLMG1152_TRIAD 12TH
STAIR + ELEVNOTES
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"BIKE ENTRY STAIR1 SCALE: 1/4" = 1'-0"
BIKE ENTRY STAIR2
SCALE: 1/4" = 1'-0"BIKE RUNNEL SECTION A3 SCALE: 1/4" = 1'-0"
BIKE RUNNEL SECTION B4
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
B
27' -
6"
9' -
2"9'
- 2"
10' -
0"
9' -
2"TO
TAL
ELEV
ATO
R T
RAV
EL D
ISTA
NC
E76
' - 3
"F3
F6
F3
F33 HR.
F1
F1
CAB
8 R
@ 6
.88"
EA
4' -
7"8
R @
6.8
8" E
A4'
- 7"
8 R
@ 6
.88"
EA
4' -
7"8
R @
6.8
8" E
A4'
- 7"
8 R
@ 6
.88"
EA
4' -
7"9
R @
6.6
7" E
A5'
- 0"
9 R
@ 6
.67"
EA
5' -
0"8
R @
6.8
8" E
A4'
- 10
1/4
"8
R @
6.8
8" E
A4'
- 3
3/4"
4 R
@ 6
.7" E
A2'
- 1
3/4"
8 R
@ 6
.7" E
A
4' -
3 1/
2"
8 R
@ 6
.7" E
A
4' -
3 1/
2"
8 R
@ 6
.88"
EA
4' -
7"
193' - 10"
T.O. VESTIBULE ROOFELEV:
T.O. PENTHOUSE ROOFELEV:
A9.75
A9.76
A9.77
MECHANICALROOM
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
11' -
3"
18"x18"x18" SUMPPUMP WITH FLUSHMOUNTED STEELGRATE COVER
LAD
DER
HEI
GH
T8'
- 6"
4' -
0"12
"
LADDER
A7.0ALTERED CUT PLANE @ 7'
A7.0ALTERED CUT PLANE @ 7'
A7.0ALTERED CUT PLANE @ 7'
A7.0ALTERED CUT PLANE @ 7'
A7.0ALTERED CUT PLANE @ 7'
A7.0ALTERED CUT PLANE @ 7'7
5
5
5
8
4
A7.0ALTERED CUT PLANE @ 7'3
6' -
8" M
IN. C
LR.
3' -
0" T
YP.
OVE
RR
UN
TO
BO
TTO
M O
F H
OIS
T BE
AM15
' - 0
"
202' - 11"
5' -
6"
195' - 3"
8" DEEP HOIST BEAM
HOISTWAY VENTING
A9.02
A9.810
A9.86
A9.85
ELEV.ELEVATOR PIT
103' - 7"
9
A9.8
PAVERS PERLANDSCAPE PLANS
A9.01
2B
A9.126
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
7A7.1
B
3
9' -
0"
8' - 0 1/2"
18"x18"x18"SUMP PUMPWITH FLUSHMOUNTEDSTEEL GRATECOVER
SWITCHC1
T.O. FOUNDATIONELEV: 103' - 7"
1' - 6"
1' -
6"
S
LADDER
DUPLEXRECEPTACLE
LIGHT
C1C1
C1
7A7.1
A
B
3
100STAIR A
102ELEV
DN UP
9' -
0"5'
- 5"
9 R
. @ 6
.67"
EA
7' -
4"
5' -
5"9
R. @
6.6
7" E
A7'
- 4"
4' -
5"
8' - 8 1/2"
5"
27' -
2"
SPC2
C2
C1
C1
C2
EXIT
113' - 4 49/64"T.O. SLABELEV:
8 T
@ 1
1" E
A
8 T
@ 1
1" E
A
GATE
12"
11"
12"
A9.82
3' - 11" 3' - 11"
C1 A9.22
11"
7A7.1
A
B
3
B00STAIR A
B02ELEV
9' -
0"5'
- 5"
9 R
. @ 6
.88"
EA
7' -
4"4'
- 5"
8' - 1"
CLEAR3' - 11" 0' - 5"
CLEAR3' - 11"
6' -
4"
8 R
. @ 6
.88"
EA
6' -
5"4'
- 5"
SP
C1
C2
C2
001
C1
EXIT
109' - 1"T.O. SLABELEV:
8 T
@ 1
1" E
A
7 T
@ 1
1" E
A
17' -
2"
UP 11"
12"
11"
A9.84
8' - 5 3/4"
7A7.1
B
3
5' -
5"8
R. @
6.8
8" E
A6'
- 5"
9 R
. @ 6
.67"
EA
7' -
4"5'
- 5"
9' -
0"
DN UP
200STAIR A
SPC2
C2
C2
C1
C1
EXIT
8 T
@ 1
1" E
A
7 T
@ 1
1" E
A
11"
12"
11"
12"
CLEAR3' - 11" 0' - 5"
CLEAR3' - 11"
C1
A9.22
7A7.1
B
3
302ELEV
300STAIR A
DN UP
8' -
11 3
/4"
5' -
5"8
R. @
6.8
8" E
A6'
- 5"
CLEAR3' - 8" 0' - 5"
CLEAR3' - 8"
5' -
5"
8 R
. @ 6
.88"
EA
6' -
5"
SPE3
E3
E3
A5
A5
8' - 2 1/4"
EXIT
R 3' - 8"
7 T
@ 1
1" E
A
7 T
@ 1
1" E
A
11"
12"
12"
11"
E3
A9.22
7A7.1
B
3
R00STAIR A
R02ELEV
7' - 10"
UP
CLEAR3' - 8 1/2" 0' - 4" 3' - 9"
8' -
11 3
/4"
5' -
5"
8 R
. @ 6
.7" E
A
6' -
5"
3' -
8"
1' -
1"8
R. @
6.7
" EA
6' -
5"
5 R. @ 6.7" EA3' - 8"
SP
E3
E3
E1
E3
A5
A5
R 3' - 8
"
7 T
@ 1
1" E
A
7 T
@ 1
1" E
A
4 T. @ 11" EA
11"
12"
11"
E3
A9.22
12"
12"
11" 12"
6A9.12
FIBER CEMENT PANEL
VERTICAL METAL PANELCOLOR: COOL METALLIC SILVER
NOT USED
CONCRETE
CONCRETE MASONRY UNIT - CMU
CAST-IN-PLACE CONCRETE PLANTER
VINYL DOOR SYSTEM - WHITE
VINYL WINDOW SYSTEM - WHITE
STOREFRONT SYSTEM - ALUMINUM
DECORATIVE METAL PANEL GUARDRAILPER DETAIL 2/A9.11
PATIO PRIVACY SCREEN
METAL FENCE OR SECURITY GATEPER PLAN
BOLT-ON JULIET BALCONY
EXHAUST LOUVER(PAINT TO MATCH ADJACENT SIDING)
AIR INTAKE VENT
ELEVATOR HOISTWAY VENT
TRANSFORMER ROOM EXHAUST VENT
FIRE DEPARTMENT CONNECTION
OVERFLOW SCUPPER
MATERIALS LIST:
1
2A
2B
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A7.1
115205.22.2013
SLMG1152_TRIAD 12TH
STAIR A
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"STAIR A - EAST7
SCALE: 1/4" = 1'-0"ELEVATOR PIT1 SCALE: 1/4" = 1'-0"
STAIR A - LEVEL 13SCALE: 1/4" = 1'-0"STAIR A - LEVEL B12
SCALE: 1/4" = 1'-0"STAIR A - LEVEL 24 SCALE: 1/4" = 1'-0"
STAIR A - LEVEL 3-75 SCALE: 1/4" = 1'-0"STAIR A - ROOF6
*SEE 1/A7.1 FORALTERED CUT PLANE
*SEE 1/A7.1 FORALTERED CUT PLANE
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
D
F1
F1
F33 HR.
F3
F6
F3
4 R
@ 6
.75"
EA
2' -
3"8
R @
6.7
5" E
A
4' -
6"
8 R
@ 6
.75"
EA
4' -
6"
8 R
@ 6
.88"
EA
4' -
7"
11' -
3"
27' -
6"
9' -
2"9'
- 2"
10' -
0"
9' -
2"
8 R
@ 6
.88"
EA
4' -
7"8
R @
6.8
8" E
A4'
- 7"
8 R
@ 6
.88"
EA
4' -
7"8
R @
6.8
8" E
A4'
- 7"
8 R
@ 6
.88"
EA
4' -
7"5'
- 0"
5' -
0"8
R @
6.8
8" E
A4'
- 7"
8 R
@ 6
.88"
EA
4' -
7"
UNIT
UNIT
UNIT
UNIT
STAIR EXITDISCHARGE
TRANSFORMERROOM
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
TYP.
3' -
0"
A9.125
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
ELEV.AVG. GRADE
116' - 1 1/4"
1A7.21
F1
F1
F33 HR.
F3
F3
F6
11' -
3"
27' -
6"
9' -
2"9'
- 2"
10' -
0"
9' -
2"
15' -
11
1/2"
8 R
@ 6
.88"
EA
4' -
5 1/
2"8
R @
6.8
8" E
A4'
- 8
1/2"
8 R
@ 6
.88"
EA
4' -
5 1/
2"8
R @
6.8
8" E
A4'
- 8
1/2"
8 R
@ 6
.88"
EA
4' -
5 1/
2"9
R @
6.6
7" E
A5'
- 1
1/2"
9 R
@ 6
.67"
EA
4' -
10 1
/2"
8 R
@ 6
.88"
EA
4' -
7"8
R @
6.8
8" E
A4'
- 7"
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
A9.83
A9.84
5A9.12
1A7.2
D
2A7.2
1
4' -
9"8
R @
6.8
75" E
A6'
- 5"
3' -
11"
15' -
1"
4' -
9"
8 R
@ 6
.875
" EA
6' -
5"3'
- 11
"
UP
SP
EXIT
C2
C1C1
109' - 1"T.O. SLABELEV:
7 T
@ 1
1" E
A
7 T
@ 1
1" E
A
R 3'
- 8"
A9.84
CLEAR3' - 8 3/4"
0' - 4"
3' - 11" CLR
8' - 5"
CLEARR 3'
- 8"
11"
1A7.2
D
2A7.2
1
10' -
4"
4' -
10"
8 R
. @ 6
.67"
EA
7' -
4"3'
- 11
"
8 R
. @ 6
.67"
EA
6' -
5"3'
- 11
"
DN
UP
SP
EXIT
C1C1
116' - 9"T.O. SLABELEV:
113' - 8"T.O. SLABELEV:
7 T
@ 1
1" E
A
7 T
@ 1
1" E
A
GATE
DN
11"
11"
12"
3 R
. @ 6
.67"
EA
1' -
10"
2 T.
@ 1
1" E
A
12"
A9.82
8' - 5"
CLEAR3' - 8"
0' - 4"
3' - 11" CLR
CLEA
R
R 3'
- 8"
BLD
G.
EXIT
C4
C4C4
11"
12"
12"
11"
1A7.2
D
2A7.2
1
4' -
0"
9 R
. @ 6
.67"
EA
7' -
4"3'
- 11
1/4
"
11' -
4"
3' -
11 1
/4"
UPDN
SP
EXIT
E3
C1
T.O. SLABELEV:
8 T
@ 1
1" E
A
7 T
@ 1
1" E
A
CLEAR3' - 8 1/4"
0' - 4"
3' - 11"
CLEA
R
R 3'
- 8"
11"
12"
11"
12"
1A7.2
D
2A7.2
14'
- 10
"
8 R
. @ 6
.88"
EA
6' -
5"4'
- 0"
4' -
10"
8 R
. @ 6
.88"
EA
6' -
5"4'
- 0"
UPDN
SP
EXIT
E3
E3E3
7 R
@ 1
1" E
A
7 R
@ 1
1" E
A
CLEAR3' - 8"
0' - 4"CLEAR3' - 8"
15' -
3"
R 3'
- 8"
8' - 11 3/4"
12"
11"
12"
11"
1A7.2
D
2A7.2
1
UP
SP
E3
E3E3
2' - 9"
5' -
5 1/
4"8
R @
6.7
" EA
6' -
5"4'
- 0"
15' -
10
1/4"
7 T
@ 1
1" E
A
5' -
5 1/
4"8
R @
6.7
" EA
6' -
5"4'
- 0"
7 T
@ 1
1" E
A
CLEAR3' - 8"
0' - 4"
3' - 8" CLR
R 3
' - 8
"
R 3' - 8" E3
8' - 11 3/4"
R 3'
- 8"
11" 12"
12"
11"
12"
5A9.12
WALL TYPE + SOFFIT KEY
2-HR FIRE-RATED WALL
CONCRETE WALL
CMU WALL
STEEL OR WOOD STUD WALL
SOFFIT/LOWERED CEILING
SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A7.2
115205.22.2013
SLMG1152_TRIAD 12TH
STAIR B
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"STAIR B - EAST1
SCALE: 1/4" = 1'-0"STAIR B - NORTH2
SCALE: 1/4" = 1'-0"STAIR B - LEVEL B13
SCALE: 1/4" = 1'-0"STAIR B - LEVEL 14
SCALE: 1/4" = 1'-0"STAIR B - LEVEL 25
SCALE: 1/4" = 1'-0"STAIR B - LEVEL 3-76
SCALE: 1/4" = 1'-0"STAIR B - ROOF7
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.AVG. GRADE
116' - 1 1/4"
6
10' -
10"
0' -
5"7'
- 0"
0' -
10"
1' -
6"
A9.15
A9.46
A9.01
A9.62
ELEV.LEVEL 1
118' - 3"
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
ELEV.LEVEL 5
155' - 9"
A9.47
A9.01
A9.515
A9.511
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
A9.17
A9.13
A9.42
A9.41
A9.03
A9.45
ELEV.LEVEL 2
128' - 3"
ELEV.LEVEL B1
109' - 1"
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
1
A9.01
A9.110
A9.55
A9.57
A9.12
A9.51
A9.53
A9.14
A9.13
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A8.0
115205.22.2013
SLMG1152_TRIAD 12TH
WALL SECTIONS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/2" = 1'-0"WALL SECTION (EAST ENTRY)1 SCALE: 1/2" = 1'-0"
WALL SECTION (NORTH ENTRY)2 SCALE: 1/2" = 1'-0"WALL SECTION (SOUTH)3 SCALE: 1/2" = 1'-0"
WALL SECTION (WEST)4
4" TOPPING SLAB OVER W/P
EXPANSION JOINT(PER W/P CONSULTANT)
SLOPE PER CIVIL/STRUCTURAL
WATERPROOFING LAYERS(PER W/P CONSULTANT)
TERMINATION BAR(PER W/P CONSULTANT)
TERMINATION BAR (PERW/P CONSULTANT)
WATERPROOFING LAYERS(PER W/P CONSULTANT)
F2
C1CONTINUOUS BENTONITE WATERSTOP
SHORING SYSTEM PERSHORING CONSULTANT
PVC DRAIN PIPE(PER CIVIL).TIGHT-LINETO STORM
CONT.BENTONITEWATERSTOP
EXPANSION JOINT
CONT. BUTYL TAPETERMINATES VAPOR
RETARDER
PVC DRAINS(PER SHORING)
FREE DRAININGGRAVEL
(PER SHORING)
FOOTING &FOUNDATIONWALL(PER STRUCT.)
C2
F6
PROVIDE MIN. R-5RIGID INSUL. @
THERMAL BREAK.PROVIDE R-10
RIGID INSUL. FOR24" INBOARD
FROM PERIMETER.
GRID
SHORINGSYSTEM PERSHORINGCONSULTANT
F6
EXPANSION JOINT
CONT. BUTYL TAPE TERMINATESVAPOR RETARDER
CONT. BENTONITEWATERSTOP
PVC DRAIN PIPE(PER CIVIL).TIGHT-LINE TOSTORM
FREE-DRAINING GRAVEL
WATERPROOFING LAYERS(PER W/P CONSULTANT)
FREE DRAININGGRAVEL
(PER SHORING)
C2
GENERAL DETAIL NOTES:
• NOTE: REFER TOBUILDING ENVELOPECONSULTANT DRAWINGSFOR ALL WATERPROOFINGAND AIR BARRIER DETAILS.
CONT. BUTYLTAPE
TERMINATESVAPOR
RETARDER
WATERPROOFING LAYERS(PER W/P CONSULTANT)
LAP FILTER FABRIC 12" MIN.
CONTINUOUSBENTONITE
WATERSTOP
FOOTING, NTS (PER STRUCT.)
RATSLAB(AS REQ'D)
CONT.BENTONITE
WATERSTOP
C1
F6
(CRYSTALLINECONCRETE PER
W/P CONSULTANT)CONCRETESTEM WALL
CONTINUOUSWATERSTOP
DRAINAGE MATERIAL
F2
C2
UNIT
C2
3' -
6"3'
- 9
3/4"
0' -
10"
A9.512
A9.54
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.0
115205.22.2013
HC, SLMG1152_TRIAD 12TH
DETAILS -CONCRETE
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1 1/2" = 1'-0"FLOOR @ SLAB ON GRADE - TRASH AREA/ALLEY5
SCALE: 1 1/2" = 1'-0"TYP. CANT. FOOTING1
SCALE: 1 1/2" = 1'-0"TYP. SPREAD FOOTING3
SCALE: 1 1/2" = 1'-0"ELEVATOR PIT FOOTING2
SCALE: 1 1/2" = 1'-0"SECTION: EAST WINDOW WELL4
REFERENCE W/P DETAIL: 3/BE-1.00 REFERENCE W/P DETAIL: 5/BE-1.00
REFERENCE W/P DETAIL: 2/BE-1.00
REFERENCE W/P DETAIL: 4/BE-1.00
REFERENCE W/P DETAIL: 1/BE-1.10
GENERAL DETAIL NOTES:
• NOTE: REFER TOBUILDING ENVELOPECONSULTANT DRAWINGSFOR ALL WATERPROOFINGAND AIR BARRIER DETAILS.
WATERPROOFINGLAYERS (PER W/PCONSULTANT)
CONTINUOUS METALFLASHING
EXTEND ROOFMEMBRANE UP PARAPET
R1
MIN. R-38 BATTINSULATION FOR18" INTO ROOFCAVITY
GRID
WALL PER PLAN
FIBER REINFORCED CEMENT PANEL
WATERPROOFINGLAYERS (PER W/PCONSULTANT)
RIM JOIST
CONTINUOUS METALFLASHING
F1
R-21 BATTINSULATION
GRID
WALL PER PLAN
WATERPROOFINGLAYERS (PER W/PCONSULTANT)
CONTINUOUS METALFLASHING
F2
GRID
WALL PER PLAN
F1
FIBER REINFORCEDCEMENT PANEL SIDINGPER ELEV
WATERPROOFING LAYERS(PER W/P CONSULTANT)
RIM JOIST PER STRUCT.
R-21 BATTINSULATION
PANEL REVEALSPER ELEV
WALL PER PLAN
THRU-WALL FLASHING
F3
FIBER REINFORCEDCEMENT PANEL SIDING(PER ELEVATION)
WATERPROOFING LAYER(PER WATERPROOFINGCONSULTANT)
2" POLYISO RIGIDINSULATION,MAINTAIN 2" MIN.AT EDGE OF SLAB
GRID
WALL PER PLAN
WALL PER PLAN
THRU-WALL FLASHING
CONCRETE COLUMN(PER STRUCT.)
RESILIENTCAULKING
GRID
WALL PER PLAN
WALL PER PLAN
2" RIGID INSULATION
CONCRETE COLUMN(PER STRUCT.)
RESILIENTCAULKING
C2
GRID
C2ALIGN GYPSUM WALLBOARD FOR SMOOTHFINISH, SHIM AS REQUIRED
ALIGN GYPSUM WALLBOARD FOR SMOOTHFINISH, SHIM AS REQUIRED
2" RIGID INSULATION
C2
F3
GRID
LEVEL 2
WALL PER PLAN
EXT.
UNIT
UNIT(BATHROOM)
CONCRETE COLUMN(PER STRUCT.)
RESILIENTCAULKING
WALL PER PLAN
GRID
2" RIGID INSULATION
PREFINISHED METAL
BREATHER MEMBRANE
W/P LAYERS (PERW/P CONSULTANT)
FIBER REINFORCEDCEMENT PANEL
GRID
WALL PER PLAN
4" T
YP.
PER ROOF PLAN
4"
R1
FIBER REINFORCEDCEMENT PANELSIDING PER ELEV
WATERPROOFINGLAYERS (PER W/PCONSULTANT)
HIGH TEMPATURESELF ADHESIVEMEMBRANE
1' -
6"
PARAPET FRAMINGBY TRUSS MFR.REFER TO STRUCT.FOR FURTHERINFORMATION
T.O. PARAPET
PANEL REVEALSPER ELEV
2% SLOPE
PREFINISHED METALFACIA WITH DRIP
FIBER REINFORCEDCEMENT PANELSIDING, ON 2 3/4"EXT PLY WOOD
1/2"
PRE-FIN DRIP EDGE
FIBER REINFORCEDCEMEMT PANEL
TRUSSINTEGRATED W/PARAPET FRAMEPER STRUCT.
FIBER REINFORCEDCEMENT PANELSIDING, SHOWNBEYOND WHEREOCCURS
PRE-FINISHED METALCOPING
GRID
WALL PER PLAN
C2
C2F3
GRID
TERMINATION BAR PERW/P CONSULTANT
CONTINUOUSWATERSTOP
LOUVERED VENT CAP
BRAKE FORM SHROUD
ENSURE CONTINUITYOF AIR BARRIER,PROVIDE SEAL AT ALLPENETRATIONS
GRID
WALL PER PLAN
EXTERIOR CLADDING(SEE BLDG. ELEVATIONS)
LOUVERED VENT CAP
BRAKE FORM SHROUD
ENSURE CONTINUITYOF AIR BARRIER,PROVIDE SEAL AT ALLPENETRATIONS
RIM JOIST, TYP.
GRID
WALL PER PLAN
INTERIOR
METAL SIDINGPER ELEV
CORNER CLIPFOR DRYWALLINSTALLATION
WALL PER PLAN
WRB LAYERS(PER W/P CONSULTANT)
GRID
GR
ID
LINE OF METALSIDING ABOVE
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.1
115205.22.2013
HC, SLMG1152_TRIAD 12TH
DETAILS - EXTERIORWALLS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1 1/2" = 1'-0"EXT. WALL AT TYPICAL PARAPET (METAL SIDING)3
SCALE: 1 1/2" = 1'-0"EXTERIOR WALL AT RIMJOIST (METAL SIDING)2
SCALE: 1 1/2" = 1'-0"EXTERIOR WALL AT SLAB EDGE (METAL SIDING)1
SCALE: 1 1/2" = 1'-0"PANEL SIDING AT WOOD FLOOR (FC PANEL)6
SCALE: 1 1/2" = 1'-0"EXTERIOR WALL AT SLAB EDGE (FC PANEL)5
SCALE: 1 1/2" = 1'-0"PARTY WALL (FIRE PARTITION) @ CONC. COLUMN13
SCALE: 1 1/2" = 1'-0"PARTY WALL (FIRE PARTITION) @ CONC. COLUMN12
SCALE: 1 1/2" = 1'-0"EXT. CONCRETE AT CONCRETE SLAB (METAL SIDING)10SCALE: 1 1/2" = 1'-0"
FURRING AT EXT. CONC. COLUMN (METAL SIDING)14
SCALE: 3" = 1'-0"TYPICAL PARAPET (METAL SIDING)4
SCALE: 1 1/2" = 1'-0"CORNICE FRAME AT PARAPET (FC PANEL)7
SCALE: 1 1/2" = 1'-0"EXT. CONCRETE AT SLAB EDGE11
SCALE: 3" = 1'-0"DETAIL: VENTING THROUGH EXT. WALL (TYPE IA)9
SCALE: 3" = 1'-0"DETAIL: VENTING THROUGH EXT. WALL (TYPE VA)8
SCALE: 1 1/2" = 1'-0"EXT. BLDG. CORNER @ BIKE ENTRY (LEVEL 1)15
REFERENCE W/P DETAIL: 7/BE-1.10
REFERENCE W/P DETAIL: 12/BE-2.00
REFERENCE W/P DETAIL: 9/BE-2.00REFERENCE W/P DETAIL: 5+6/BE-2.00
REFERENCE W/P DETAIL: 3/BE-2.10
REFERENCE W/P DETAIL: 7/BE-2.10
REFERENCE W/P DETAIL: 6/BE-4.00 REFERENCE W/P DETAIL: 6/BE-5.00
REFERENCE W/P DETAIL: 2/BE-5.00
INTERIOR INTERIOR
EXTERIOR CORNER - LEVELS 3-7 EXTERIOR CORNER - LEVEL 2
METAL SIDINGPER ELEV
METAL SIDINGPER ELEV
METAL SIDINGPER ELEV METAL SIDING PER ELEV
CORNER CLIPFOR DRYWALLINSTALLATION
CORNER CLIPFOR DRYWALLINSTALLATION
WALL PER PLAN
WRB LAYERS(PER W/P CONSULTANT)
WALL PER PLAN
WRB LAYERS(PER W/P CONSULTANT)
GRID GRID
GR
ID
GR
ID
CORRIDOR
UNIT
EXTERIOR
CORRIDOR
UNIT
EXTERIOR
CORRIDOR
UNIT
EXTERIOR
LEVELS 3-7
LEVEL 2
LEVEL 1
REF. A
REF. A
REF. A
REF. B
REF. B
REF. B
METAL SIDING PER ELEV
METAL SIDING PER ELEV
CORNER CLIPFOR DRYWALLINSTALLATION
CORNER CLIPFOR DRYWALLINSTALALTION
WRB LAYERS(PER W/P CONSULTANT)
WRB LAYERS(PER W/P CONSULTANT)
CORRIDOR
UNIT
EXTERIOR
LEVEL B1
REF. A
REF. B
CORNER CLIPFOR DRYWALLINSTALALTION
GRID
GRID
GRID
GRID
METAL SIDING BELOW
METAL SIDING BELOW
WALL PER PLAN
WALL PER PLAN
C2 C2
C2 C2
DOOR PER PLAN
WINDOW PER PLAN
CORRIDOR
UNIT
EXTERIOR
CORRIDOR
UNIT
CORRIDOR
UNIT
EXTERIOR
LEVELS 3-7
LEVEL 2
LEVEL 1
METAL SIDINGPER ELEV
CORNER CLIPFOR DRYWALLINSTALLATION
CORNER CLIPFOR DRYWALLINSTALALTION
WRB LAYERS(PER W/PCONSULTANT)
METAL SIDING BELOW
METAL SIDING BELOW
GRID
GRID
GRID
LINE OF METALSIDING ABOVE
EXTERIOR
METAL SIDINGPER ELEV
WRB LAYERS(PER W/PCONSULTANT)
CORNER CLIPFOR DRYWALLINSTALALTION
WALL PER PLAN
WALL PER PLAN
WALL PER PLAN
C2
C2
C25'-0
" WAL
L EX
TEN
SIO
N
0' - 8 1/2"
0' - 8 1/2"
5'-0
" WAL
L EX
TEN
SIO
N5'
-0" W
ALL
EXTE
NSI
ON
INTERIOR CORNER - LEVELS 3-7
METAL SIDINGPER ELEV
METAL SIDINGPER ELEV
CORNER CLIPFOR DRYWALLINSTALLATION
WALL PER PLAN
WRB LAYERS(PER W/PCONSULTANT)
EXTERIOR
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.2
115205.22.2013
AuthorChecker1152_TRIAD 12TH
DETAILS - EXTERIORWALLS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1 1/2" = 1'-0"TYP. EXT. BLDG. CORNER WALL STACK (METAL SIDING)4
SCALE: 1 1/2" = 1'-0"EXT. WINDOW CONDITIONS @ SOUTH CORRIDOR1SCALE: 1 1/2" = 1'-0"
EXT. WINDOW CONDITIONS @ NORTH CORRIDOR2SCALE: 1 1/2" = 1'-0"TYP. INT. BLDG. CORNER WALL STACK (METAL SIDING)3
REFERENCE W/P DETAIL: 2+8/BE-2.00
REFERENCE W/P DETAIL: 1/BE-2.00
ELEVATOR
EXTERIORSTAIR
LOBBY
ELEVATOR
EXTERIORSTAIR
CORRIDOR
BASEMENT + LEVEL 1 LEVEL 2
ELEVATOR
EXTERIORSTAIR
CORRIDOR
LEVELS 3-7
CORNER CLIPFOR DRYWALLINSTALLATION
CORRIDOR
ELEVATOR
UNIT
BASEMENT + LEVEL 1 LEVEL 2 LEVELS 3-7
CORRIDOR
ELEVATOR
UNIT
CORNER BEAD
CORRIDOR
ELEVATORUNIT
CORNER BEAD
FURR W/ 2" RIGIDINSULATION AND 1
LAYER OF 5/8" GWBTO IMPROVE UNITACOUSTICS NEAR
ELEVATOR
FURR W/ 2" RIGIDINSULATION AND 1
LAYER OF 5/8" GWBTO IMPROVE UNITACOUSTICS NEAR
ELEVATOR
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.3
115205.22.2013
AuthorChecker1152_TRIAD 12TH
DETAILS - EXTERIORWALLS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1 1/2" = 1'-0"PLAN: ELEVATOR + STAIR WALL CONNECTION1
SCALE: 1 1/2" = 1'-0"PLAN: ELEVATOR + CORRIDOR WALL CONNECTION2
TYP.
1/4"
1' - 6"
1' -
6"
GRID
WATERPROOFINGLAYERS PER W/P
CONSULTANT
R-21 BATTINSULATION
FIBER REINFORCEDCEMENT PANEL SIDINGPER ELEVATION
METAL SIDINGPER ELEV
SHEATHING PERSTRUCT.
WOOD FURRING
WATERPROOFING LAYERSPER W/P CONSULTANT
METAL BALCONET RAIL
VINYL SLIDERSEALANT (PER W/PCONSULTANT)
BOLT IN SLOTTED HOLEW/SPACER
DIAGONAL BRACING,PER STRUCT.
WOOD FRAMINGPER STRUCT.
PT BLOCKING FOR RAIL
WALL PER PLAN
GRID
SOLID HATCH:INSTALL 1/2" GYPSUMFIREBLOCKING EVERY 20 FEET ATVERTICAL STUD BREAKS
GRID
1' -
6"
1' - 6"
1/4"
WATERPROOFINGLAYERS PER W/P
CONSULTANT
FIBER REINFORCEDCEMENT PANEL SIDING,PER ELEV
METAL SIDINGPER ELEV
FURRING PER MFR.
WATERPROOFINGLAYERS PER W/PCONSULTANT
RIGID INSUL.METAL BALCONET RAIL
VINYL SLIDER
BOLT IN SLOTTED HOLEW/SPACER
CONCRETE COLUMNPER PLANS SEALANT AND BACKER ROD
METAL FRAMING ANDCROSSBRACING PER
STRUCT.
WALL PER PLAN
GRID
SOLID HATCH:INSTALL 1/2" GYPSUMFIREBLOCKING EVERY 20 FEET ATVERTICAL STUD BREAKS
METAL BALCONET RAIL
KNIFE PLATE
VINYL SLIDER
SEALANT PER W/PCONSULTANT
A4
4" SPHERE SHALLNOT PASSPER IBC 1013.2
WALL PER PLAN
GR
ID
METAL BALCONET RAIL
KNIFE PLATE
VINYL SLIDER
SEALANT (PER W/PCONSULTANT)
B4
ANCHOR TOSTRUCTURE PER MFR
4" SPHERE SHALLNOT PASSPER IBC 1013.2
GR
ID
WALL PER PLAN
SLIDER DOOR PER SCHEDULE
SLIDER DOOR PER SCHEDULE
WATERPROOFING LAYERS
FIBER REINFORCED CEMENT PANELSIDING
F1
METAL BALCONET
4" SPHERE SHALL NOT PASS PER IBC 1013.2
METAL SILL PAN, SHIM FOR DRAINAGE
GRID
WALL PER PLAN
THRU-WALL FLASHING CONTINUOUS ALONGWALL @ EVERY WINDOW HEAD, TYP
SLIDER DOOR PER SCHEDULE
SLIDER DOOR PER SCHEDULE
WATERPROOFING LAYERS(PER W/P CONSULTANT)
FIBER REINFORCED CEMENT PANELSIDING (PER ELEV)
METAL BALCONET
COUNTERSUNK ANCHOR BOLT PERSTRUCT W/FIRE TREATED BLOCKINGRIPPED TO SIZE FOR SILL
ANCHOR TO STRUCTURE PER MFR
METAL SILL PAN FLASHING,SHIM FOR DRAINAGE
4" SPHERE SHALL NOTPASS PER IBC 1013.2
WALL PER PLAN
GRID
THRU-WALL FLASHING CONTINUOUS ALONGWALL @ EVERY WINDOW HEAD, TYP
1' -
6"
1' - 6"WINDOW PER SCHEDULE
STOREFRONT PERSCHEDULE WHEREOCCURS PER PLANS
SPRAY FOAM INSULATION
SLOPE PRE-FIN METAL SILLFLASHING W/ DRIP EDGE
FIBER CEMENTPANEL SIDING
STEEL FRAMING 12" O.C.
STEEL CHANNEL PERSTRUCT.
ATTACHMENT PERSTRUCTURAL
PRE-FIN DRIP EDGE
CEDAR SLAT SOFFIT
PREFINISHED Z-METAL TRIM
GRID
WALLPER
PLAN
SOLID HATCH:INSTALL 1/2" GYPSUMFIREBLOCKING EVERY 20 FEETAT HORIZONTAL STUD BREAKS
1' -
6"
6' - 0" AT ENTRYWINDOW PER SCHEDULE
STOREFRONT PERSCHEDULE WHEREOCCURS PER PLANS
SPRAY FOAM INSULATIONSLOPE
3/8" PER FOOT PRE-FIN METAL SILLFLASHING W/ DRIP EDGE
FIBER CEMENTPANEL SIDING
STEEL FRAMING 12" O.C.
STEEL CHANNEL PERSTRUCT.ATTACHMENT PERSTRUCTURAL
PRE-FIN DRIP EDGE
PREFINISHED Z-METAL TRIM
GRID
WALLPER
PLAN
CEDAR SLAT SOFFIT
SOLID HATCH:INSTALL 1/2" GYPSUMFIREBLOCKING EVERY 20 FEETAT HORIZONTAL STUD BREAKS
GENERAL DETAIL NOTES:
• NOTE: REFER TOBUILDING ENVELOPECONSULTANT DRAWINGSFOR ALL WATERPROOFINGAND AIR BARRIER DETAILS.
SLIDER DOOR PER SCHEDULE
METAL BALCONET
SILL FLASHING (PER W/P CONSULTANT)
4" SPHERE SHALL NOT PASS PER IBC 1013.2
1' -
6"
SPRAY FOAM INSULATION
SLOPEPRE-FIN METAL SILLFLASHING W/ DRIP EDGE
FIBER CEMENT PANEL SIDING
STEEL FRAMING, SEE STRUCT
SHEATHING PER STRUCT
B
SOLID HATCH:INSTALL 1/2" GYPSUMFIREBLOCKING EVERY 20FEET AT HORIZONTALSTUD BREAKS
ATTACHMENT PER STRUCT
WATERPROOFING LAYERS(PER W/P CONSULTANT)
PRE-FIN DRIP EDGE
1' - 6"
FIBER REINFORCEDCEMENT PANEL SIDINGPER ELEVATION
FURRING PERMANUFACTURER
1/4"GRID
WALL PER PLAN
SOLID HATCH:INSTALL 1/2" GYPSUMFIREBLOCKING EVERY20 FEET AT VERTICALSTUD BREAKS
FIBER CEMENT PANEL
W/P LAYERS(PER W/P CONSULTANT)
THRU-WALL FLASHINGCONTINUOUS ALONGWALL @ EVERY WINDOWHEAD, TYP
WINDOW (PER SCHEDULE)
INTERIOR EXTERIOR
FURRING
GRIDWINDOW (PER SCHEDULE)
CAP FLASHING WITH DRIPOVER TOP EDGE OFPANEL SIDING
METAL SIDING
W/P LAYERS(PER W/P CONSULTANT)
THRU-WALL FLASHINGCONTINUOUS ALONGWALL @ EVERY WINDOWHEAD, TYP
WINDOW (PER SCHEDULE)
INTERIOR EXTERIOR
GRIDWINDOW (PER SCHEDULE)
CAP FLASHING WITH DRIPOVER TOP EDGE OFMETAL SIDING
BACKER ROD / SEALANT
FURRING
INTERIOREXTERIOR
WINDOW (PER SCHEDULE)
CAP FLASHING WITH DRIPOVER TOP EDGE OFMETAL SIDING
BACKER ROD / SEALANT
METAL SIDING
W/P LAYERS(PER W/P CONSULTANT)
BLOCKING
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.4
115205.22.2013
HC, SL, MCMG1152_TRIAD 12TH
DETAILS - WINDOWS+ SLIDERS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1 1/2" = 1'-0"SIDING TRANSITION @ FIN (TYPE VA)10
SCALE: 1 1/2" = 1'-0"SIDING TRANSITION CONC. COLUMN @ FIN9
SCALE: 1 1/2" = 1'-0"VINYL SLIDER JAMB AT PARTY WALL (TYPE VA)4
SCALE: 1 1/2" = 1'-0"VINYL SLIDER JAMB AT PARTY WALL (TYPE 1A)3
SCALE: 1 1/2" = 1'-0"VINYL SLIDERS HEAD AND SILL AT FLOOR (TYPE VA)2
SCALE: 1 1/2" = 1'-0"VINYL SLIDERS HEAD AND SILL AT CONCRETE SLAB1
SCALE: 1 1/2" = 1'-0"STOREFRONT HEAD AT ENTRY CANOPY (NORTH)7
SCALE: 1 1/2" = 1'-0"STOREFRONT HEAD AT ENTRY CANOPY (EAST)6
SCALE: 1 1/2" = 1'-0"VINYL SLIDER SILL @ CONC. SLAB/FRAME (TYPE 1A)5
SCALE: 1 1/2" = 1'-0"BLDG. CORNER @ STOREFRONT + FIN11 REFERENCE W/P DETAIL: 7/BE-3.20
REFERENCE W/P DETAIL: 6/BE-3.20
REFERENCE W/P DETAIL: 4/BE-4.00
REFERENCE W/P DETAIL: 1/BE-4.00
REFERENCE W/P DETAIL: 2/BE-4.00
REFERENCE W/P DETAIL: 7/BE-4.00
SCALE: 1 1/2" = 1'-0"VINYL WINDOW AT VA FLOOR (METAL / FC PANEL)12 SCALE: 3" = 1'-0"
VINYL WINDOW AT VA FLOOR (METAL / FC PANEL)8
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
METAL SIDING
W/P LAYERS
PREFINISHED METALHEAD FLASHING
WINDOW (PER SCHEDULE)
INTERIOR
EXTERIOR
HEADER PER STRUCTURAL
SHIM TO MATCHSIDING AT TYPE 1ACONSTRUCTION
GRID
WALL PER PLAN
METAL SIDING
WINDOW (PERSCHEDULE)
W/P LAYERS
INTERIOR
EXTERIOR
3/4" C-GIRT
METALFLASHING
GR
ID
WALL PER PLAN
BACKER ROD & SEALANT
SILL
WINDOW (PER SCHEDULE)
SHIM AS REQ'D
INTERIOR EXTERIOR
METAL SIDING
W/P LAYERS
CAP FLASHING WITH DRIPOVER TOP EDGE OFPANEL SIDING
SPACER
GRID
WALL PER PLAN
3/4" C-GIRT
GENERAL DETAIL NOTES:
• NOTE: REFER TOBUILDING ENVELOPECONSULTANT DRAWINGSFOR ALL WATERPROOFINGAND AIR BARRIER DETAILS.
C2
UNIT
VINYL WINDOWPER SCHEDULE
STRAP PER MFR.FASTENER PER MFR.
BACKER RODAND SEALANT
C2
UNITVINYL WINDOWPER SCHEDULE
STRAP PER MFR.
FASTENER PER MFR.
BACKER ROD AND SEALANT
SHIM AS REQ'D
VINYL WINDOWPER SCHEDULE
STRAP PER MFR.
FASTENER PER MFR.SHIM AS REQ'D
UNIT
C2
BACKER ROD ANDSEALANT
WATERPROOFINGPER W/PCONSULTANT
SLOPE:1/4" PER FT.
METAL SIDING
WINDOW (PERSCHEDULE)
W/P LAYERS
INTERIOR
EXTERIOR
3/4" C-GIRT
METAL FLASHING
WALL PER PLAN
WALL PER PLAN
GR
ID
METAL SIDING
W/P LAYERS(PER W/P CONSULTANT)
PREFINISHED METALHEAD FLASHING
WINDOW (PER SCHEDULE)
INT. EXT.
3/4" C-GIRT
WALL PER PLAN
GRID
BACKER ROD & SEALANT
SILLWINDOW (PER SCHEDULE)
SHIM AS REQ'D
INT. EXT.
METAL SIDING
W/P LAYERS
3/4" C-GIRT
CAP FLASHING WITH DRIPOVER TOP EDGE OFPANEL SIDING
GRID
WALL PER PLAN
BACKER ROD & SEALANT
SILL
WINDOW (PER SCHEDULE)
SHIM AS REQ'D
INTERIOREXTERIOR
FIBER CEMENT PANEL
W/P LAYERS(PER W/P CONSULTANT)
PANEL CLIP
CAP FLASHING WITH DRIPOVER TOP EDGE OFPANEL SIDING
SPACER
WALL PER PLAN
GRID
FIBER CEMENT PANEL
WINDOW (PERSCHEDULE)
W/P LAYERS(PER W/P CONSULTANT)
INTERIOR
EXTERIOR
SPACERMETALFLASHING
WALL PER PLAN
GR
ID
FIBER CEMENT PANEL
W/P LAYERS(PER W/P CONSULTANT)
THRU-WALL FLASHING CONTINUOUS ALONGWALL @ EVERY WINDOW HEAD, TYP
WINDOW (PER SCHEDULE)
INTERIOR
EXTERIOR
HEADER PER STRUCTURAL
PANEL CLIP
SPACER
GRID
WALL PER PLAN
BACKER ROD & SEALANT
SILL
WINDOW (PER SCHEDULE)
SHIM AS REQ'D
INT.
EXT.
FIBER CEMENT PANEL
W/P LAYERS(PER W/P CONSULTANT)
PANEL CLIP
CAP FLASHING WITH DRIPOVER TOP EDGE OFPANEL SIDING
GRID
WALL PER PLAN
FIBER CEMENT PANEL
WINDOW (PERSCHEDULE)
W/P LAYERS(PER W/P CONSULTANT)
INTERIOR
EXTERIOR
SPACER
METAL FLASHING
WALL PER PLAN
GR
ID
FIBER CEMENT PANEL
W/P LAYERS(PER W/P CONSULTANT)
THRU-WALL FLASHING CONTINUOUS ALONGWALL @ EVERY WINDOW HEAD, TYP
WINDOW (PER SCHEDULE)
INT.
EXT.
PANEL CLIP
WALL PER PLAN
GRID
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.5
115205.22.2013
HC, SLMG1152_TRIAD 12TH
DETAILS - WINDOWS+ STOREFRONT
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 3" = 1'-0"HEAD: VINYL WINDOW AT TYPE VA (METAL SIDING)3
SCALE: 3" = 1'-0"JAMB: VINYL WINDOW AT TYPE VA (METAL SIDING)2
SCALE: 3" = 1'-0"SILL: VINYL WINDOW AT TYPE VA (METAL SIDING)1
SCALE: 3" = 1'-0"HEAD: VINYL WINDOW AT CONCRETE12 SCALE: 3" = 1'-0"
JAMB: VINYL WINDOW AT CONCRETE8 SCALE: 3" = 1'-0"SILL: VINYL WINDOW AT CONCRETE4
SCALE: 3" = 1'-0"JAMB: VINYL WINDOW AT TYPE 1A (METAL SIDING)6
SCALE: 3" = 1'-0"HEAD: VINYL WINDOW AT TYPE 1A (METAL SIDING)7
SCALE: 3" = 1'-0"SILL: VINYL WINDOW AT TYPE 1A (METAL SIDING)5SCALE: 3" = 1'-0"
SILL: VINYL WINDOW AT TYPE VA WALL (FC PANEL)9
SCALE: 3" = 1'-0"JAMB: VINYL WINDOW AT TYPE VA WALL (FC PANEL)10
SCALE: 3" = 1'-0"HEAD: VINYL WINDOW AT TYPE VA WALL (FC PANEL)11
SCALE: 3" = 1'-0"SILL: VINYL WINDOW AT TYPE 1A WALL (FC PANEL)13
SCALE: 3" = 1'-0"JAMB: VINYL WINDOW AT TYPE 1A WALL (FC PANEL)14
SCALE: 3" = 1'-0"HEAD: VINYL WINDOW AT TYPE 1A WALL (FC PANEL)15
REFERENCE W/P DETAIL: 5/BE-3.10 REFERENCE W/P DETAIL: 6/BE-3.10REFERENCE W/P DETAIL: 4/BE-3.10
REFERENCE W/P DETAIL: 3/BE-3.10
REFERENCE W/P DETAIL: 2/BE-3.10
REFERENCE W/P DETAIL: 1/BE-3.10
REFERENCE W/P DETAIL: 9/BE-3.10
REFERENCE W/P DETAIL: 8/BE-3.10
REFERENCE W/P DETAIL: 7/BE-3.10 + 2/BE-3.00
PT PLYWOOD
CORNER FRAMINGPER STRUCTURAL
WINDOW PERSCHEDULE
WINDOW PER SCHEDULE
INTERIOR
BREAK METAL PAINTEDTO MATCH WINDOWCOLOR
1x4 PT WOOD WITH 1/2" PTPLYWOOD BUILT-UPWOODEN PROFILE
GRID
GR
ID
BLOCKING TO FINISHINTERIOR CORNER
PT PLYWOOD
CORNER FRAMINGPER STRUCTURAL
WINDOW PERSCHEDULE
WINDOW PER SCHEDULE
INTERIOR
BREAK METAL PAINTEDTO MATCH WINDOWCOLOR
1x4 PT WOOD WITH 1/2" PTPLYWOOD BUILT-UPWOODEN PROFILE
GRID
GR
ID
BLOCKING TO FINISHINTERIOR CORNER
9 1/2"
9 1/
2"
9 1/2"
9 1/
2"
SHIMSEALANT &BACKER ROD
STOREFRONTWINDOW SYSTEM
MIN. 3/8":12" SLOPE
EXTERIOR
INT.
CONTINUOUS BENTONITEWATERSTOP
0' -
4"
WATERPROOFING PERW/P CONSULTANT
MDF OVER GYP BD
DOOR PER PLAN
MIN. 3/8":12" SLOPE
EXTERIOR
INT.
CONTINUOUS BENTONITEWATERSTOP
WATERPROOFING PERW/P CONSULTANT
SHIM
STOREFRONTWINDOW SYSTEM
C2
UNITVINYL WINDOWPER SCHEDULE
STRAP PER MFR.
FASTENER PER MFR.
BACKER ROD AND SEALANT
SHIM AS REQ'D
VINYL WINDOWPER SCHEDULE
FASTENER PER MFR.SHIM AS REQ'D
UNIT
C2
BACKER ROD ANDSEALANT
WATERPROOFINGPER W/PCONSULTANT
SLOPE:1/4" PER FT.
STOREFRONT WINDOW SYSTEM
B1
WOOD ACCENT SOFFIT
ALIGN
B.O. SOFFIT
C2
C2
METAL FLASHINGAROUND DOOR OPENING
UNIT PATIO DOOR(PER SCHEDULE)
INTERIOR
EXTERIOR
C2
FLUID APPLIEDELASTOMERIC COATING(PER WATERPROOFING)
SHIM
BARRIER FREETHRESHOLD
OUTSWING DOOR(PER SCHEDULE)
SLAB WP - EXTENDBEYONDTHRESHOLD
RECESS INCONCRETE SLAB
F6 F7
LEVEL B1ELEV. 102'-4"
GRID
FILL WITH SEALANT
FINISH FLOOR LEVEL
PEDESTAL PAVERSYSTEM
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.6
115205.22.2013
AuthorChecker1152_TRIAD 12TH
DETAILS - WINDOWS+ STOREFRONT
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 3" = 1'-0"JAMB: VINYL WINDOW AT CORNER (LEVELS 2-7)1
SCALE: 3" = 1'-0"SILL: STOREFRONT @ MAIN ENTRY - LEVEL 12
SCALE: 3" = 1'-0"THRESHOLD: STOREFRONT @ MAIN ENTRY - LEVEL 13
REFERENCE W/P DETAIL: 9/BE-3.20
REFERENCE W/P DETAIL: 10/BE-3.20SCALE: 3" = 1'-0"STOREFRONT AT CORNER CONDITION6
SCALE: 3" = 1'-0"JAMB: VINYL WINDOW AT CONCRETE5
SCALE: 3" = 1'-0"SILL: VINYL WINDOW AT CONCRETE4
REFERENCE W/P DETAIL: 10/BE-3.10
REFERENCE W/P DETAIL: 11/BE-3.10
REFERENCE W/P DETAIL: 12/BE-3.10
SCALE: 3" = 1'-0"HEAD: STOREFRONT WINDOW (TYPE IA WALL)7
SCALE: 3" = 1'-0"JAMB (EXT): VINYL DOOR/WINDOW SYSTEM @ CONCRETE WALL8
SCALE: 3" = 1'-0"JAMB: EXT. UNIT SWING DOOR9
SCALE: 3" = 1'-0"THRESHOLD: EXT. UNIT SWING DOOR10
RESILIENT CAULKING
RESILIENT CAULKING
CONCRETE COLUMN(PER STRUCT.)
WALL PER PLAN
WALL PER PLAN
SOLID BLOCKINGPERPENDICULAR TOJOISTS OR ADDITIONALPARALLEL JOISTSUNDER WALL
UNIT
UNIT
UNIT
UNIT
F1
A1
3-HOUR OCCUPANCY SEPARATION R-2 TO M/B/R
ANCHOR BOLT(PER STRUCT.)UNIT UNIT
A1
F3
UNIT UNITB1
RESILIENT CAULKUNITUNIT
A4
R1MINERAL WOOLFIRE BLOCKING
ANCHORBOLT (PERSTRUCT.)
UNITUNIT
UNITUNIT
3 HR HORIZONTALSEPERATION
PT WOODPLATE WITHSILL SEALER
A4
B4
F3
DEFLECTION CHANNEL
MINERALWOOL FIREBLOCKING
RESILIENTCAULKING
RESILIENTCAULKING
UNITUNIT
UNITUNIT
CONDITIONPERPENDICULARTO JOISTS
CONDITIONPARALLELTO JOISTS
F2
A4
A4
RESILIENTCAULKING
FLOOR/CEILINGASSEMBLY PER PLAN
WALLASSEMBLYPER PLAN
0' -
9"
12" MIN. + 24" MAX.AS SHOWN IN PLAN
7'-0
" MIN
. TO
F.F
.
28 GA. 1 1/2" X 1 1/2"METAL CLIP, TYP.
5/8" TYPE 'X'GWB AT SOFFIT
EXHAUST VENTS
NOTE: NOUNPROTECTEDOPENINGSWITHIN 3'-0" OFPROPERTY LINE
MINERAL WOOLFIRE BLOCKING
SEALANT, TYP.(SEE SHEET A0.4)
SOLID WOODBLOCKING
NO PENETRATIONSEXCEPT FOR SYSTEMSSERVICING THEVERTICAL SHAFT
VERTICALSHAFT
UNIT
UNIT
RESILIENT CAULK, FORSOUND ATTENUATION & AIRSEALANT
A5
F2
A5
ANCHOR BOLT(PER STRUCT.)
NO PENETRATIONSEXCEPT FORSYSTEMS SERVICINGTHE VERTICAL SHAFT
VERTICALSHAFT
UNIT
SEALANT, TYP.
A5
F3
C2
RESILIENT CAULK, FORSOUND ATTENUATION &AIR SEALANT
SEALANT, TYP.
SEALANT, TYP.
SOLID WOOD BLOCKING
NO PENETRATIONSEXCEPT FOR SYSTEMSSERVICING THEVERTICAL SHAFT
UNIT
VERTICALSHAFT
ROOF
R1
A5
F1
F1
ENCLOSE THE FAN UNITWITHIN A BOX OF 3-1/2"BATT INSULATIONSECURLY FASTENED TOTHE ADJACENT FRAMINGPER SBC CA 713.4
EXHAUST DUCT
FAN BOX
EXHAUST DUCT
FAN BOX
WRAP 1 1/2" HIGHDENSITY MINERAL WOOLFIBER INSULATIONAROUND DUCT FOR 10'FROM OPENING PER SBCCA 713.4
WRAP 1 1/2" HIGHDENSITY MINERAL WOOLFIBER INSULATIONAROUND DUCT FOR 10'FROM OPENING PER SBCCA 713.4
ENCLOSE THE FAN UNITWITHIN A BOX OF 3-1/2"BATT INSULATIONSECURLY FASTENED TOTHE ADJACENT FRAMINGPER SBC CA 713.4
CAULK AT ALL WIREPENETRATIONS
CAULK AT ALL OPENINGS
UNIT
STANDARD PLASTIC ELECTRICAL BOX
SEAL AT FACE TODRYWALL WITH JOINTCOMPOUND OR WITHCAULKED FOAMCOVER PLATE GASKET
WALL PER PLAN
4" M
AX.
FIRE RATED SEMI RECESSEDFIRE EXTINGUISHER CABINETPER SPEC
FASTENERS PER MFR.
WALL PER PLAN
GENERAL DETAIL NOTES:
• NOTE: REFER TOBUILDING ENVELOPECONSULTANT DRAWINGSFOR ALL WATERPROOFINGAND AIR BARRIER DETAILS.
FLOOR/CEILINGPER PLAN
AS R
EQ'D
MIN
12" MIN. + 24" MAX.AS SHOWN IN PLAN
INTERIORPARTITIONASSEMBLYPER PLAN
28 GA. 1 1/2" X 1 1/2"METAL CLIP, TYP.
5/8" TYPE 'X'GWB AT SOFFIT
EXHAUST VENTS
NOTE: NOUNPROTECTEDOPENINGSWITHIN 3'-0" OFPROPERTY LINE
7'-0
" MIN
. TO
F.F
.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.7
115205.22.2013
HC, SLMG1152_TRIAD 12TH
DETAILS - INTERIORWALLS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1 1/2" = 1'-0"PLAN: PARTY WALL AT CONC. COLUMN9
SCALE: 1 1/2" = 1'-0"INTERIOR PARTITION AT WOOD FLOOR12
SCALE: 1 1/2" = 1'-0"INT. PARTITION AT TRANSFER SLAB11 SCALE: 1 1/2" = 1'-0"
PARTY WALL AT ROOF (FIRE PARTITION)3
SCALE: 1 1/2" = 1'-0"PARTY WALL AT TRANSFER SLAB (FIRE PARTITION)1
SCALE: 1 1/2" = 1'-0"PARTY WALL AT WOOD FLOOR (FIRE PARTITION)2
SCALE: 1 1/2" = 1'-0"SOFFIT AT PARTY WALL8
SCALE: 1 1/2" = 1'-0"FIRE BARRIER AT WOOD FLOOR6
SCALE: 1 1/2" = 1'-0"FIRE BARRIER AT TRANSFER SLAB5
SCALE: 1 1/2" = 1'-0"FIRE BARRIER AT ROOF7
SCALE: 1 1/2" = 1'-0"EXHAUST VENTING THROUGH JOISTS14
SCALE: 1 1/2" = 1'-0"ELECTRICAL BOX AT PARTY WALL13
SCALE: 1 1/2" = 1'-0"SEMI RECESSED FIRE EXTINGUISHER CABINET15
SCALE: 1 1/2" = 1'-0"SOFFIT AT INT. PLUMBING PARTITION (UNIT 115)4
STAINLESS STEEL PLACARD.PLACE AT EACH LEVEL. ALIGNW/ ELEVATOR CALL BUTTONS
ELEVATOR CALL BUTTONS,BELOW
NOTE READS: 'In Case of Fire, DONOT Use Elevators. Use Exit Stairs.Elevator will be Recalled to Lobby.'
In Case of Fire,DO NOT Use
Elevators. UseExit Stairs.
Elevator will beRecalled to
Lobby.
6"
3 1/2"
STAIR A
P1 THRU ROOFNO ROOF ACCESSDOWN TO LEVEL 1
FOR EXITDISCHARGE
TEXT IS EXAMPLE ONLY. PROVIDEFOR ACTUAL PROJECT SITUATION.ALL TEXT SHALL BE 1" HIGH BLOCKLETTERING W/ 1/4" STROKE UNLESSOTHERWISE NOTED.
STAIRWAY IDENTIFICATION, 1-1/2"TEXT HEIGHT
NOTE WHETHER THERE IS ROOFACCESS FOR FIRE DEPT. ANDWHETHER THERE IS A ROOFHATCH
FLOOR LEVEL DESIGNATION, 5"TEXT HEIGHT W/ 3/4" STROKE
TERMINUS OF THETOP AND BOTTOM OFSTAIR
BRAILLE FLOOR LEVELDESIGNATION,PLUS LEVEL ANDDIRECTION OF EXIT DISCHARGE
SEE GENERAL NOTES ANDSBC 1022.8 FOR MOREDETAILED REQUIREMENTS.
NOTE THE STORY OF AND THEDIRECTION TO THE EXIT DISCHARGE
18" M
INIM
UM
12" MINIMUM
2X3X1/4" STEEL PLATEW/ RUBBER SILENCER(TYP. TWO (2) PLACES)
SPRING LOADEDHINGES WELDED TOGATE SUPPORT
1 1/4" STEEL PIPEGATES W/ RADIUSEDCORNERS, PAINTED
HANDRAIL ABOVE, TYP.
1 1/4" STEEL PIPEGATES W/ RADIUSEDCORNERS, PTD.
PLACARD, PERSBC 1011.6
SPRING LOADEDHINGES WELDED TOGATE SUPPORT
SOLID WOOD BLOCKINGAS NECESSARY
NOT ANEXIT
2' -
10"
CL
CL
3' - 8"
3' - 3"
1 1/2" METAL RAIL
2X6 BLOCKING
ALL BRACKETSATTACHED TO BLOCKINGW/ THREE (3) SCREWSMINIMUM
RAIL ATTACHED TOSUPPORT W/ TWO (2)SET SCREWSPROVIDED BY MFGR.
TOP OF RAIL 2'-10" ABOVE STAIRNOSING, TYP.
NOTE: ALL HANDRAIL ENDSTO BE RETURNED TO WALL
2X6 BLOCKING
1 1/2"1 1/2".2 1/2"
4'-0
" MAX
.
2'-1
0"AB
OVE
NO
SIN
G
STAI
R N
OSI
NG
STAI
R N
OSI
NG
MOUNTING BRACESEVENLY SPACED 4'-0"O.C. MAX.
1 1/2" METAL HANDRAIL
ALIGN W/ NOSINGOF LANDING
.
.
4" M
IN, 7
" MAX
.
VAR
IES,
PER
PLA
N
1/2" MAXIMUMRADIUS
CONCRETESTAIR (PERSTRUCT.)
1"
MIN. REQ.'D
11" TREAD
STEEL GRATE STAIR TREADSW/ NON-SLIP NOSING
STEEL CHANNEL STRINGERSPER STRUCTURAL
TREAD SUPPORTS BYSTAIR MFR.
WELD 1/4" STEEL CAPAT EXPOSED ENDS
STEEL GRATE LANDINGBY STAIR MFR.
1/2" RADIUS MAX.
CONNECTION PERSTAIR MFR. ANDSTRUCT.
1"
(MIN. REQ'D)
11" TREAD
(7" M
AX/ 4
" MIN
REQ
'D)
VAR
IES
PER
PLA
N
1/4" ANSI COMPLIANT GRATING, TYP.
NOTE: ALL STEEL GALVANIZED
12 GA STEEL RISER PLATE
FLOOR PER PLANS
STEEL PLATE PER STRUCTURALPERIMETER C CHANNEL W/STEEL GRATE LANDING
2 BOLTS EACH SIDE PERSTRUCTURAL
WRB, LAPPED ONTO KNIFEPLATE PER WATERPROOFING
CLADDING
WALL TYPE PER PLANS
KNIFE PLATE PER STRUCTURAL
STEEL ANGLE RIM
.
MIN. DIMENSION TOACCOMODATECLADDING - F.V. TYP.
EXTEND LANDING ATTHRESHOLD, WHERE OCCURS
GENERAL DETAIL NOTES:
• NOTE: REFER TOBUILDING ENVELOPECONSULTANT DRAWINGSFOR ALL WATERPROOFINGAND AIR BARRIER DETAILS.
(7" M
AX. /
4" M
IN R
EQ'D
)VA
RIE
S PE
R P
LAN
UNIT
WATERPROOFINGLAYERS (PER W/PCONSULTANT)
R3
GRID
WALL PER PLAN
ROOF DECK
STEEL KNIFE PLATE CONNECTION ANDWATERPROOFING PER STRUCTURALAND WP CONSULTANT
STEEL STAIR PERMANUFACTURER
CURB WITH METAL CAPFLASHING W/ CLEATS ANDGASKETED FASTENERS - CURBSLOPE EQUAL TO TRUSS SLOPE
CANTILEVERED SUPPORTFRAMING FOR COMPOSITEDECKING - PROVIDE CLEARANCEFOR SLOPED CURB BELOW
STEEL KNIFE PLATE CONNECTION W/STAIR END CHANNEL PER STRUCTURAL
OPTIONAL METAL COVER PLATE ATTACHEDTO STAIR AND ALLOW TO SPAN OVER DECKING
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.8
115205.22.2013
HC, SLMG1152_TRIAD 12TH
DETAILS - STAIR +ELEV
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 3" = 1'-0"ELEVATOR PLACARD7
SCALE: 3" = 1'-0"STAIRWELL SIGNAGE1
SCALE: 1 1/2" = 1'-0"PLAN: BARRIER GATE2
SCALE: 3/4" = 1'-0"ELEVATION: BARRIER GATE3
SCALE: 3" = 1'-0"HANDRAIL PLAN & SECTION4
SCALE: 3/4" = 1'-0"HANDRAIL REQUIREMENTS5
SCALE: 1 1/2" = 1'-0"TYP. CONCRETE STAIR6
SCALE: 1" = 1'-0"TYP. STAIR @ INTERMEDIATE LANDING10
SCALE: 1 1/2" = 1'-0"STAIR LANDING AT TYPE V9
SCALE: 1 1/2" = 1'-0"TYP. INTERIOR WOOD STAIRS AT CONCRETE SLAB8SCALE: 1 1/2" = 1'-0"
TYPICAL STAIR @ ROOF ATTACHMENT11
3 BP CORRECTION 02.28.13
C1
STEEL DOOR FRAME
SHIM PERMANUFACTURER'SREQUIREMENTS
EXPANDING FOAM TAPE
SEALANT JOINT &CLOSED CELLBACKER ROD
CASING
PREHUNG DOOR (PER SCHEDULE)
1/2" STOP
3/4" FRAME
SHIM AS REQUIRED
WALL PER PLAN
BI-FOLD ORBYPASS DOOR(PER SCHEDULE)
TYP. GWBCORNER BEAD
WALL PER PLANSTEEL DOOR FRAME
SHIM AS NEEDED
BACKER ROD & SEALANT
C1
.3-1/2"MIN
PREFERRED
3/4" FRAME
SHIM ASREQUIRED
CASING
PERPENDICULAR INT.WALL LOCATION (ASLOCATED ON PLAN)
1/2" STOP
PREHUNG DOOR(PER SCHEDULE)
WALL PER PLAN
0' - 7"0' -
0 1/
4"
DOOR SWEEP, AS REQUIRED
1/2" MAX. THRESHOLD,BARRIER FREE W/ SLIP-RESISTANT COATING
DOOR (PER SCHEDULE)
STEEL DOOR FRAME, 73/4" DEPTH, BEYOND
(1) BI-FOLD DOORS(PER SCHEDULE)
HEADER(PER STRUCT.)
WALL PER PLAN
METAL DOORFRAME PER DOORSCHEDULE
WALL PER PLAN
HEADER (PER STRUCT.)
METAL DOOR FRAME PER DOORSCHEDULE
WALL PER PLAN
GENERAL DETAIL NOTES:
• NOTE: REFER TOBUILDING ENVELOPECONSULTANT DRAWINGSFOR ALL WATERPROOFINGAND AIR BARRIER DETAILS.
WALL PER PLAN
METAL SIDINGPER ELEVATIONS
HEADER PER STRUCTURAL
WINDOW WRAP PERENVELOPE CONSULTANT
HEAD FLASHING
METAL DOOR FRAMEPER SCHEDULEDOOR PER SCHEDULE
BACKER ROD AND SEALANT
SEALANT PER SIDING MFR.
2" RIGID INSULATION
SPRAY FOAM PERW/P CONSULTANT
SEALANT
METAL DOOR FRAMEPER DOOR SCHEDULE
WINDOW WRAP(PER WATERPROOFING)'C' METAL TRIM
METAL SIDING(PER ELEVATIONS)
WALL PER PLAN
SPRAY FOAM PERW/P CONSULTANT
STEEL DOOR FRAME
SHIM PERMANUFACTURER'SREQUIREMENTS
EXPANDING FOAM TAPE
SEALANT JOINT &CLOSED CELLBACKER ROD
C2
STEEL DOOR FRAME
SHIM AS NEEDED
BACKER ROD & SEALANT
C2
METAL DOORFRAME PER DOORSCHEDULE
3/4" FRAME
SHIM ASREQUIRED
CASING
PERPENDICULAR INT.WALL LOCATION (ASLOCATED ON PLAN)
1/2" STOP
PREHUNG DOOR(PER SCHEDULE)
WALL PER PLAN
MIN2 3/8"
GENERAL DOOR DETAIL NOTES:
• ALL DOORS LEADING FROM AUNIT TO THE EXTERIOR (OR)FROM A UNIT TO A CORRIDORWILL HAVE WEATHERSTRIPPINGAND SWEEPS AT THETHRESHOLD.
STAINLESS STEEL SILL PANOVER S.A.M.: VERIFYCOMPATIBILITY WITH S.A.WP SHEET W/ MFRF6
MIN 1" RIGID INSUL
EXPANSION JOINT
WATERPROOFING LAYERS(PER W/P CONSULTANT)
INTERIOREXTERIOR
SLOPE LANDING TO FLOORDRAIN AT BASEMENT LEVEL,AND TOWARD EXTERIOR ON
UPPER LEVELS
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.9
115205.22.2013
HC, SLMG1152_TRIAD 12TH
DETAILS - DOORS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 3" = 1'-0"HEAD (INT): METAL DOOR AT CONCRETE8
SCALE: 3" = 1'-0"HEAD (INT): DOOR AT INTERIOR WALL2
SCALE: 3" = 1'-0"JAMB (INT): BI-FOLD & BYPASS DOOR3SCALE: 3" = 1'-0"
JAMB (INT): METAL DOOR AT CONCRETE7
SCALE: 3" = 1'-0"JAMB (INT): DOOR AT INTERIOR WALL1
SCALE: 3" = 1'-0"TYP. DOOR THRESHOLD14
SCALE: 3" = 1'-0"HEAD (INT): BI-FOLD DOOR4
SCALE: 3" = 1'-0"JAMB (INT): DOOR AT 1 HR WALL5
SCALE: 3" = 1'-0"HEAD (INT): DOOR AT 1 HR WALL6SCALE: 3" = 1'-0"
HEAD (EXT): METAL DOOR AT METAL SIDING10
SCALE: 3" = 1'-0"JAMB (EXT): METAL DOOR AT METAL SIDING9
SCALE: 3" = 1'-0"HEAD (EXT): METAL DOOR AT CONCRETE WALL12
SCALE: 3" = 1'-0"JAMB (EXT): METAL DOOR AT CONCRETE WALL11
REFERENCE W/P DETAIL: 1/BE-3.20
REFERENCE W/P DETAIL: 2/BE-3.20
REFERENCE W/P DETAIL: 5/BE-3.20
REFERENCE W/P DETAIL: 4/BE-3.20
SCALE: 3" = 1'-0"JAMB (INT): DOOR AT 1 HR WALL - UNIT ENTRY15
SCALE: 3" = 1'-0"THRESHOLD: AT EXIT STAIR (TYP.)16
ROOF DRAIN W/ COMBINEDFLASHING COLLAR / GRAVELSTOP SIZED PER PLUMBINGCODE
OVERFLOW DRAIN W/ COLLAR2" ABOVE SUMP FLOOR
FLASHING & ROOFINGPLIES PER W/PDETAILSINSTALL DRAINS IN
LOWER SUMP
CONNECT PRIMARYLINE TO STORM
SYSTEM
CONNECT TO EXTERNAL OVERFLOW.SCUPPER PER ELEVATIONS.
REFER TOMANUFACTURER'S
DETAILS
ROOFTOP
EXTERIORBREAKFORM METALFLASHING TO WRAP FACEOF PARAPET BEYOND
MEMBRANE ROOFINGSYSTEM TO BE WELDED TOPVC COATED METALSCUPPER ALL SIDES
BREAKFORM PVC COATEDMETALSCUPPER PIECE THROUGHPARAPET
SIDING RUNS BEHIND
WATERPROOFING LAYERS
SLOPE MIN1/4" PER FT.
WALL PER PLAN
ROOF DECK
UNIT
GUARDRAIL
COMPOSITE DECKING
P.T. WOOD SLEEPERS(NOTCHED FOR DRAINAGE)
SLOPE:1/4" PER FT.
2" x 2" TOP RAIL
2" x 2" POST
4" DIAMETER SPHERE SHALLNOT PASS PER IBC 1012.3
2" x 2" BOTTOM RAIL
42" A
.F.F
. GU
ARD
HEI
GH
T
GUARDRAILPOWDER-COATED BLACK
SHOP DRAWINGS MUST BEREVIEWED BY ARCHITECT
STEEL GUTTERAND DOWNSPOUT
CORRUGATED METAL CANOPYPOWDER-COATED BLACK
WAL
L PE
R P
LAN
4' - 8"
SHOP DRAWINGS MUST BEREVIEWED BY ARCHITECT
6A9.10
8x4 TUBE STEEL
GUTTER
C8 STEELCHANNEL
0' -
1"4'
- 11
"0'
- 1"
5' -
1"
1/2"
PLANDOWNSPOUT
4' - 10"
STEEL FRAME ANDCORRUGATED METAL
CANOPY WILL BEPOWDER-COATED BLACK
SLOPE -SEE ROOF
PLAN
R2
WRB LAYERS(PER W/P CONSULTANT)
TYP. PARAPET
SLOPE
T.O. ROOF DECKSEE ELEVS
MIN
42"
ABV
DEC
K
T.O. PARAPETELEV: xxx
ATTACH WALL PER STRUCT
TRUSS PER STRUCT
INSULATE WITH STONE WOOLINSULATION (WHERE REQ'D)
UNIT
FIBER CEMENT SIDING
WOOD SLEEPER
R2
ROOF TRAY SYSTEM PER LANDSCAPE
METAL EDGING (PERLANDSCAPE)
COMPOSITE DECKING
T.O. ROOF DECKELEV: xxx
SLOPE
GRAVEL PER LANDSCAPE
WOOD SLEEPER
WATERPROOFING (PERENVELOPE CONSULTANT)
8" OF RIGID INSULATION
3/4" PLYWOOD
P.T. WOOD SLEEPERS (CUT TOROOF SLOPE/CRICKET)
THERMALLY BROKENTHRESHOLD, SET INBED OFSEALANTCOMPOSITE DECKING
METAL FLASHING
R2
TRUSSSLOPE
ELEVATOR LOBBY FFE /T.O. ROOF DECKSEE ELEVS
JOISTS PER STRUCT
CRICKET FOR DRAINAGESTR
UC
TUR
E
1' -
7"
R3
ACOUSTICAL BATT PERACOUSTICAL CONSULTANT
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.10
115205.22.2013
AuthorChecker1152_TRIAD 12TH
DETAILS - ROOF
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1 1/2" = 1'-0"ROOF DRAIN/OVERFLOW COMBINATION1
SCALE: 1 1/2" = 1'-0"SECTION: ROOF SCUPPER + DOWNSPOUT2SCALE: 1 1/2" = 1'-0"
ROOF DECKING @ GUARDRAIL ATTACHMENT5
SCALE: 1" = 1'-0"GUARDRAIL @ ROOF6
SCALE: 1 1/2" = 1'-0"BIKE ENTRY CANOPY - SECTION8
SCALE: 1 1/2" = 1'-0"BIKE ENTRY CANOPY - PLAN9
REFERENCE W/P DETAIL: 1/BE-5.00
REFERENCE W/P DETAIL: 8/BE-5.00
SCALE: 1 1/2" = 1'-0"FALSE PARAPET4SCALE: 1 1/2" = 1'-0"
PAVER EDGE TO GREEN ROOF TRANSITION7
SCALE: 1 1/2" = 1'-0"EXT. DOOR THRESHOLD @ COMPOSITE ROOF DECK3
1x3 HORIZONTALCEDAR SLATS
C2
5' -
0"0'
- 6"
0' - 2" 6' - 2" SOUTH PATIO 0' - 2"
SLAB ON GRADE SLOPE:1/4" PER FT.
C2
PEDESTAL SYSTEM
SLAB W/P - EXTENDTO TO TOP OF CURB
STEP INCONCRETE SLAB
5' -
6"
WALLPERPLAN
WALLPERPLAN
2"x3" METALANGLE
1x3 HORIZONTALCEDAR SLATS
PLAN
1/2"1"
METAL FRAME ANDATTACHMENTS ANODIZEDALUMINUM
4" DIAMETER SPHERE SHALLNOT PASS PER IBC 1012.3
42" A
.F.F
. GU
ARD
HEI
GH
T
SLIDING DOOR BEYOND
2"x1" SOLID STEEL TOPRAILING BAR ANDBOTTOM RAILING BARPER STRUCTURAL DETAIL
1/2" x 1/2" METAL TUBE
GUARDRAIL WILLBE POWDER-COATED BLACK
2" x 2" TOP RAIL
2" x 2" POST
7'-0
" SE
CU
RIT
Y FE
NC
E H
EIG
HT
WIRE MESH TO BEINSTALLED ON SIDECLOSEST TOPROPERTY LINE
NOTE:
SECURITY ENTRY GATE LOCATIONS:STEEL FRAMEPOWDER-COATED - MATCH"BENJAMIN-MOORE 2002-10"MESHPOWDER-COATED - MATCH"BENJAMIN-MOORE 2002-10
SECURITY FENCE LOCATIONS:STEEL FRAME + MESHPOWDER-COATED BLACK
TUBE STEEL, MAX1" DIA
FOUNDATION PERCONTRACTOR(DESIGN/BUILD)
TYP
0' -
4 1/
2"
7'-0
" SE
CU
RIT
Y FE
NC
E H
EIG
HT
PER PLAN*VARIES* 3' - 0"
1' -
6"2'
- 7"
3' -
4"
STEELPLATE
STEELCHANNEL
STEELCHANNELFRAME
GRADE
WALLPERPLAN
FOUNDATION PERCONTRACTOR
(DESIGN/BUILD)
1' - 0"
TYP
0' -
4 1/
2"
TUBESTEEL,MAX 1" DIA
0' -
1"
2"x2" ALUMINUMCHANNEL
1 1/
2"
1" OPEN ALUM.GRATE DECKING,PER SBC CA705.5
12"x3.5"x.5" CCHANNEL
3"x3"x.25" ANGLE
2"x2" ALUMINUMRAILING
PERFORATEDMETAL PANEL, MIN3/16" DIA OPENINGS,MIN 50% TOTALOPEN AREA
PLAN
SECTION(PERFORATED METAL PANEL@ ALL STAIR LOCATIONS)
1"
WAL
L PE
R P
LAN
WALL PER PLAN
2"x2" ALUMINUMCHANNEL
PERFORATED PANEL@ STAIR GUARDRAIL(OR)4" X 4" WELDED WIRE@ ALL OTHERGUARDRAILS
ELEVATION(PERFORATED METAL PANEL@ ALL STAIR LOCATIONS)
42"
*VARIES*
4" DIAMETERSPHERE SHALL NOTPASS PER IBC 1012.3
1"
WAL
L PE
R P
LAN
ELEVATION(WELDED WIRE @ ALL GUARDRAILLOCATIONS OTHER THAN STAIRS)
* VARIES *
FRAME AND METAL PANEL:POWDER-COATED, MATCH"BENJAMIN-MOORE 2002-10"
FRAME AND METAL MESH:ANODIZED ALUMINUM
1.5"x1.5"ALUMINUMRAILING
1"
WAL
L PE
R P
LAN
ELEVATION(WELDED WIRE @ ALL GUARDRAILLOCATIONS OTHER THAN STAIRS)
* VARIES *
FRAME AND METAL MESH:ANODIZED ALUMINUM
SIDE-MOUNTEDRAIL BEYOND.SEE 6/A9.00
METAL PANEL TO COVERFLASHING AND TOPPINGSLAB EDGE
WELDED WIRECLOTH, 4" X 4"SPACING, MIN 60%OPEN AREA
3' -
6"
WELDED WIRECLOTH, 4" X 4"SPACING, MIN 60%OPEN AREA
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.11
115205.22.2013
AuthorChecker1152_TRIAD 12TH
DETAILS -ATTACHMENTS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1" = 1'-0"SOUTH PATIO PRIVACY SCREEN + PEDESTAL PAVERS1
SCALE: 1" = 1'-0"GUARDRAIL @ UNIT SLIDING DOORS5 REFERENCE W/P DETAIL: 1/BE-2.10
SCALE: 1" = 1'-0"7'-0" SECURITY FENCE3 SCALE: 1" = 1'-0"
7'-0" SECURITY FENCE GATE4
SCALE: 1" = 1'-0"PERFORATED METAL PANEL GUARDRAIL2
4 BP CORRECTION 2 04.24.13
A
3
6A9.12
1' - 6"
4 1/2"
8' - 3 1/2" FIELD VERIFY 1' - 6"
11' - 8"
3' -
6"10
' - 1
1" F
IELD
VER
IFY
1' -
7"11
1/2
"
EQEQ
EQ
16' -
11
1/2"
C
D
1
5A9.12
1' - 3"
3"
8' - 5" FIELD VERIFY 1' - 6"
11' - 5"
1' -
6"2'
- 7
3/4"
12' -
10"
FIE
LD V
ERIF
Y3
3/4"
1' -
6"
18' -
9 1
/2"
EQEQ
EQEQ
A
PARAPET189' - 4"
193' - 2 3/4"T.O. COL1"
12"
9
A9.12
A9.1212
A9.1210
11
A9.12
PREFINISHED METAL
WRB
W/P LAYERS (PERW/P CONSULTANT)
FIBER REINFORCEDCEMENT PANEL
WALL PER PLAN
SEALANT W/ BONDBREAKER @ BACK
STRUCTURAL COLUMN& PLATE
STRUCTURALTENSION TIE
DOUBLE TOP PLATE
(2) STRUCTURAL BOLT
STRUCTURAL METALSPACER
PRE-FINISHEDGUTTER SLOPEDTO DRAIN
STANDING SEAM ROOF
PRE-FINISHED EAVEFLASH WITH GUTTERCLEAT
DOWNSPOUT TO ROOF
STRUCTURAL CANOPYBEAM & RAFTER - CAPEXPOSED ENDS
FLASHING CLEAT
STANDING SEAM ROOF
PRE-FINISHED RAKEFLASH
CONT FLASHING SUPPORT,CLEAT ATTACHMENT
STRUCTURAL CANOPY RAFTER- CAP EXPOSED ENDS
STANDING SEAM ROOF
STRUCTURAL CANOPYBEAM & RAFTER - CAPEXPOSED ENDS
PRE-FINISHED EAVEFLASHING
FLASHING CLEAT
D
1" 12"
189' - 4"PARAPET
T.O. COL
9
A9.12
A9.1212
A9.1210
11
A9.12
SIM
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.12
115205.22.2013
AuthorChecker1152_TRIAD 12TH
STAIR ROOFCANOPIES
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"ROOF DECK3
SCALE: 1/4" = 1'-0"CANOPY RCP - STAIR B1
SCALE: 1/4" = 1'-0"SECTION - CANOPY A6
SCALE: 3" = 1'-0"STRUCTURAL COLUMN @ PARAPET9
SCALE: 3" = 1'-0"LOWER EAVE @ STAIR CANOPY10
SCALE: 3" = 1'-0"RAKE @ STAIR CANOPY11
SCALE: 3" = 1'-0"UPPER EAVE @ STAIR CANOPY12
SCALE: 1/4" = 1'-0"SECTION - CANOPY B5
4 BP CORRECTION 2 04.24.13
HORIZONTALREVEAL TRIM
CEMENTITIOUS SIDING
WRB LAYERS(PER W/P CONSULTANT)
MIN FURRING PER MFR.
0' -
0 1/
2"
WALL TYPE PERPLAN
GRID
HORIZONTALREVEAL TRIM
CEMENTITIOUS SIDING
WRB LAYERS(PER W/P CONSULTANT)
MIN FURRING PER MFR.
0' -
0 1/
2"
WALL TYPE PERPLAN
GRID
F3
FIBER REINFORCEDCEMENT PANEL SIDING(PER ELEVATION)
WATERPROOFING LAYER(PER WATERPROOFINGCONSULTANT)
2" POLYISO RIGIDINSULATION,MAINTAIN 2" MIN.AT EDGE OF SLAB
GRID
WALL PER PLAN
WALL PER PLAN
THRU-WALL FLASHING
FURRING
WALL TYPE PERPLAN
CEMENTITIOUS SIDING
WRB LAYERS(PER W/P CONSULTANT)
C-GIRT PER WALL SCHEDULE
1/2" 1/2" 1/2"
VERTICAL REVEALTRIM
GRID
WALL TYPE PERPLAN
CEMENTITIOUS SIDING
WRB LAYERS(PER W/P CONSULTANT)
MIN FURRING PER MFR.
1/2" 1/2" 1/2"
VERTICAL REVEALTRIM
GRID
EXTRUDED OUTSIDE METALCORNER TRIM
CEMENTITIOUS SIDING
WRB LAYERS(PER W/P CONSULTANT)
MIN. FURRING PER MFR.
GRID
GRID
CORNER CLIP FORDRYWALLINSTALLATION
WALL TYPE PERPLAN
EXTRUDED OUTSIDE METALCORNER TRIM
CEMENTITIOUS SIDING
WRB LAYERS(PER W/P CONSULTANT)
MIN FURRING PER MFR.
GRID
CORNER CLIP FORDRYWALLINSTALLATION
WALL TYPE PER PLAN
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.13
115205.22.2013
SLAM1152_TRIAD 12TH
FIBER CEMENTSIDING REVEALDETAILS
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 3" = 1'-0"SECTION: HORIZONTAL REVEAL (TYPE IA)1
SCALE: 3" = 1'-0"SECTION: HORIZONTAL REVEAL (TYPE VA)2
SCALE: 1 1/2" = 1'-0"EXTERIOR WALL AT SLAB EDGE (FC PANEL)3
SCALE: 3" = 1'-0"PLAN: VERTICAL REVEAL (TYPE IA)4
SCALE: 3" = 1'-0"PLAN: VERTICAL REVEAL (TYPE VA)5
SCALE: 3" = 1'-0"PLAN: SIDING AT OUTSIDE CORNER (TYPE IA)6
SCALE: 3" = 1'-0"PLAN: SIDING AT OUTSIDE CORNER (TYPE VA)7
LEED COMPARTMENTALIZATION NOTES
AIR SEALING: ELEMENTS TO BE SEALED
THE INTERIOR AIR BARRIER IS THE DRYWALL. CONTINUITY OF THE DRYWALL ISACHIEVED THROUGH THE SEALING AND CAULKING AT THE JUNCTIONS OF THE WALLS,CEILINGS, AND FLOORS.
THROUGH REQUIRED COMPLIANCE WITH THE 2009 IBC W/ SEATTLE AMMENDMENTSCODE, THIS MIDRISE BUILDING INHERENTLY HAS AN AIR BARRIER SYSTEM THROUGHTHE IBC REQUIREMENTS FOR FIRE-RESISTANCE-RATED CONSTRUCTION. PER TABLE601, THIS TYPE I & VA BUILDING IS REQUIRED TO OBTAIN A CERTAIN LEVEL OF FIRERESISTANCE SEALING IN ALL WALL, FLOOR, AND CEILING ASSEMBLIES. CHAPTER 7OF THE 2009 IBC OUTLINES THE BLOCKING AND SEALING REQUIREMENTS TO ACHIEVETHESE LEVELS OF FIRE RESISTANCE. THESE SEALING REQUIREMENTS MINIMIZE THEPASSAGE OF FIRE, SMOKE, AND THE LEAKAGE OF AIR. THEREFORE, THE FIRESEALING REQUIREMENTS INHERENTLY ACT AS THE AIR BARRIER REQUIREMENTS.FURTHERMORE, THE "AIR SEALING: ELEMENTS TO BE SEALED" NOTES ON SHEETA9.13 DESCRIBE THE ADDITIONAL ITEMS TO BE SEALED.
DETAILS ON SHEET A9.07 SHOW THE SEALING OF WALL, CEILING, AND FLOORJUNCTIONS.
SHEETS A10.00, A10.01 AND A10.02 IDENTIFY THE MATERIALS THAT COMPRISE EACHWALL ASSEMBLY.
SEE DETAIL 7/A9.00 FOR NON-BEARING CONCRETE WALL TO UNDERSIDE OF SLABFOR BARRIER CONTINUITY
1)
2)
3)
4)
5)
AIR BARRIER CONTINUITY
ALL OPENINGS IN THE BUILDING ENVELOPE AND BETWEEN UNITS SHALL BE SEALED,CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. COMPLY WITHASHRAE 90.1-2004, 5.4.3.1: AIR LEAKAGE: THE FOLLOWING AREAS OF THE BUILDINGENVELOPE SHALL BE SEALED, CAULKED, GASKETED, OR WEATHER-STRIPPED TOMINIMIZE AIR LEAKAGE:
JOINTS AROUND FENESTRATION FRAMES.
JUNCTIONS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AT BUILDINGCORNERS, BETWEEN WALLS AND STRUCTURAL FLOORS OR ROOFS, AND BETWEENWALLS AND ROOF OR WALL PANELS.
OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH ROOFS, WALLS, ANDFLOORS.
SITE-BUILT FENESTRATION.
BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS.
JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDERS.
ALL OTHER OPENINGS IN THE BUILDING ENVELOPE.
IN ADDITION TO THE ABOVE COMPLIANCE, THE FOLLOWING SPECIFIC LOCATIONS SHALLBE SEALED, CAULKED, GASKETED, OR WEATHER-STRIPPED:
SEAL ALL PLUMBING AND ELECTRICAL PLATE AND WALL PENETRATIONS.
INSTALL NON-PAPER BASED SHEET AT TUB/SHOWER. CAULK AND INSULATE BEFOREINSTALLING TUB/SHOWER ADJACENT TO OUTSIDE WALL OF UNIT.
SEAL ALL FENESTRATION ROUGH OPENINGS.
SEAL ALL RECESSED FIXTURES (E.G. WALL HEATERS, EXHAUST FANS, MEDICINECABINETS, ETC.) IN ALL EXTERIOR WALLS, CEILINGS, AND CEILINGS BETWEEN FLOORS OFSTACKED UNITS.
SEAL ALL CEILING-MOUNTED BATH FANS AND PENETRATIONS.
SEAL ALL WALL EXHAUST FAN TERMINATIONS AT SHEATHING.
SEAL ALL PENETRATIONS IN THE RIM JOIST FRAMING, INCLUDING BLOCKING WHERE THEFLOOR JOISTS ARE CANTILEVERED.
SEAL ALL INTERIOR ELECTRICAL BOXES ON PARTY WALLS OF UNIT TO DRYWALL.
SEAL ALL ELECTRICAL WIRES PENETRATING TOP AND BOTTOM PLATES OF EXTERIORWALLS AND PARTY WALLS.
BOX-IN AND SEAL DRAIN LINE OF SHOWER AND TUB.
SEAL ALL PENETRATIONS FOR MANIFOLDS AND ACCESS HATCHES TO DRYWALL.
SEAL ALL EXTERIOR WALL PENETRATIONS FOR REFRIGERATION LINES, CONDENSATELINES, ETC.
SEAL ALONG INSIDE TOP CORNER OF TOP PLATE OF ALL EXTERIOR WALLS AFTERWALLS ARE FRAMED.
SEAL ALONG INSIDE BOTTOM CORNER OF BOTTOM PLATE WHERE IT MEETS THE SLABFLOOR AFTER WALLS ARE FRAMED.
SEAL ALONG INSIDE BOTTOM CORNER OF BOTTOM PLATE OF ALL EXTERIOR WALLSAFTER WALLS ARE FRAMED.
SEAL ALONG INSIDE OF RIM JOIST, AT TOP AND BOTTOM CORNERS WHERE RIM JOISTMEETS PLATES.
SEAL ALONG INSIDE OF BOTTOM OF FIRST STUD IN INTERIOR WALL OR HOLD BACK FIRSTSTUD TO PASS DRYWALL BEHIND STUD AFTER WALLS ARE FRAMED.
FOR INTERIOR WALL PARTITIONS, SEAL AT TOP CORNER OF TOP PLATE WHEREADJACENT TO AN UNCONDITIONED SPACE AFTER WALLS ARE FRAMED.
WHENEVER POSSIBLE, USE CONTINUOUS DRYWALL SHEETS FOR THE CEILING AND WALLSTO MINIMIZE JOINTS TO BE SEALED.
1)
a)
b)
c)
d)
e)
f)
g)
2.
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
l)
m)
n)
o)
p)
q)
r)
s)
ELEV.ROOF DECK
185' - 4"
A9.73
A9.13
ELEV.LEVEL 3
137' - 5"
ELEV.LEVEL 4
146' - 7"
CONTINUOUSAIR BARRIER
A9.72
A9.71
A9.12
A9.11
ELEV.LEVEL 7
174' - 1"
ELEV.ROOF DECK
185' - 4"
CONTINUOUSAIR BARRIER
A9.77
A9.73
A9.76
A9.72
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A9.14
115205.22.2013
SLAM1152_TRIAD 12TH
LEEDCOMPARTMENT-ALIZATIONDIAGRAMS + NOTES
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
SCALE: 1/4" = 1'-0"COMPARTMENTALIZATION - TYP UNIT SECTION A1
SCALE: 1/4" = 1'-0"COMPARTMENTALIZATION - TYP UNIT SECTION B2
WALL ASSEMBLIES: TYPE VA, INTERIORWALL TYPE WALL DETAIL ASSEMBLY DESCRIPTION FIRE SOUND THERMAL
RATING
A1TYPICAL
INTERIORPARTITION
5/8" TYPE 'X' GWB2X4 WOOD STUD WALL (PER STRUCTURAL)R-11 BATT INSULATION FOR SOUND ATTENUATION ONLY(WHERE INDICATED, PER PLAN & ALL BATHROOM LOCATIONS)5/8" TYPE 'X' GWB
NOTE: (1) WRAP PLUMBING PIPE WITH SOUND ATTENUATIONBATT(2)PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHINDTUB ENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D3273 WITH SCORE OF 10 BEHIND FIBERGLASS TUBSURROUNDS.
1 HOUR
GA WP 3510
STC: 35-39(WITH BATT INSUL)
A2INTERIORPARTITION
W/ 4" DIA. ORGREATERPLUMBING
5/8" TYPE 'X' GWB2X6 WOOD STUD @ 16" O.C. (PER STRUCTURAL)R-19 BATT INSULATION FOR SOUND ATTENUATION ONLY5/8" TYPE 'X' GWB
NOTE:(1) ADD 2ND LAYER OF 5/8" GWB NEXT TO BEDROOM (ONBEDROOM SIDE) OR LIVING ROOM (ON LIVING ROOM SIDE).(2) CAULK TOP AND BOTTOM OF GWB ON BOTH SIDES OF WALLWITH RESILIENT CAULK(3) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHINDTUB ENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D3273 WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
1 HOUR
GA WP 3510
STC: 35-39(WITH BATT INSUL)
A4TYPICAL
FIREPARTITION
(PARTY WALL)
2 LAYERS OF 5/8" TYPE 'X' GWBREPLACE 5/8" TYPE 'X' GWB W/ 1/2" PLYWOOD ONLY WHEREINDICATED PER STRUCTURAL2X4 STAGGERED WOOD STUD 8" O.C. (PER STRUCTURAL) ONCOMMON 2X6 PLATEROCK WOOL FIRE-BREAK AT 10'-0" MAX. INTERVALWRAP PLUMBING PIPE WITH SOUND ATTENUATION BATTR-19 BATT INSULATION FOR SOUND ATTENUATION2 LAYERS OF 5/8" TYPE 'X' GWB
NOTE:(1) FIRST LAYER OF GYP ON EACH SIDE OF STUD TO BECAULKED, TOP & BOTTOM, USING RESILIENT CAULK.(2) ELECTRICAL & COMMUNICATION BOXES SHALL BESEPARATED BY A MIN OF 24" ON OPPOSITE SIDES OF WALL.ALL UNUSED KNOCKOUTS SHALL BE PLUGGED. BOXESLOCATED WITHIN 24" OF EACH OTHER SHALL BE FITTEDWITH PUTTY PACKS ON THE BACKSIDE.(3) PENETRATIONS FOR SMALL PIPING AND CONDUIT WITHINWALL SHALL BE SEALED WITH RESILIENT CAULK(4) PROVIDE SOLID NON-PAPER FACED BACKERBOARDBEHIND TUB ENCLOSURES OR PAPER-FACED GWB THATMEETS ASTM D 3273 WITH SCORE OF 10 BEHIND FIBERGLASSTUB SURROUNDS
1 HOUR
GA WP 3380
STC: 55
A3CORRIDOR WALL
2 LAYERS 5/8" TYPE 'X' GWBADD 1/2" PLYWOOD ONLY WHERE INDICATED PER STRUCTURAL2X4 WOOD STUDS 16" O.C. STAGGERED 8" O.C. ON COMMON 2X6PLATEROCK WOOL FIRE-BLOCK AT 10'-0" MAX. INTERVAL.R-19 SOUND ATTENUATION BATT INSULATION2 LAYERS 5/8" TYPE 'X' GWB
2 HOUR
GA WP 3910
STC: 50 - 54
WALL ASSEMBLIES: TYPE IA, INTERIORWALL TYPE WALL DETAIL ASSEMBLY DESCRIPTION FIRE SOUND THERMAL
RATING
B1TYPICAL
INTERIORPARTITION
5/8" TYPE 'X' GWB3 5/8" STEEL STUD WALL @ 16" O.C. (PER STRUCTURAL)R-11 BATT INSULATION FOR SOUND ATTENUATION ONLY (WHERE -INDICATED, PER PLAN & ALL BATHROOM LOCATIONS)5/8" TYPE 'X' GWB
NOTE: (1) WRAP PLUMBING PIPE WITH SOUND ATTENUATION BATT(2) PROVIDE SOLID NON-PAPER FACED BACKEBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS.
1 HOUR
GA WP 1072
STC: 45-49(WITH BATT INSUL)
B2INTERIORPARTITION
W/ 4" DIA. ORGREATERPLUMBING
5/8" TYPE 'X' GWB6" STEEL STUD @ 16" O.C. (PER STRUCTURAL)R-19 BATT INSULATION FOR SOUND ATTENUATION ONLY5/8" TYPE 'X' GWB
NOTE:(1) ADD 2ND LAYER OF 5/8" GWB NEXT TO BEDROOM (ON BEDROOMSIDE) OR LIVING ROOM (ON LIVING ROOM SIDE).(2) ON CONCRETE SLAB CAULK TOP AND BOTTOM OF GWB ON BOTHSIDES OF WALL WITH RESILIENT CAULK(3) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
1 HOUR
GA WP 1072
STC: 45-49(WITH BATT INSUL)
B4TYPICAL
FIREPARTITION
(PARTY WALL)
1 HOUR
GA WP 1021
STC: 56
VAR
IES
•••
•
••
••
•••
•
••••
•••
•••
••
•
••••
A5FIRE BARRIER(SHAFT WALL)
ATSTAIR/ELEVATOR/
(NO PENETRATIONS)
5/8" TYPE 'X' GWB5/8" TYPE 'X' GWB OR 1/2" PLYWOOD SHEATHING ONLY WHEREINDICATED BY STRUCTURAL2X4 STAGGERED WOOD STUD (PER STRUCTURAL) ON COMMON2X8 PLATEROCK WOOL BATT INSULATION AT 10'-0" MAX. INTERVALWRAP PLUMBING PIPE WITH SOUND ATTENUATION BATTR-19 BATT INSULATION FOR SOUND ATTENUATION5/8" TYPE 'X' GWB
NOTE:(1) ON CONCRETE SLAB, FIRST LAYER GWB ON EACH SIDE OFSTUD TO BE CAULKED, TOP AND BOTTOM USING RESILIENTCAULK(2) RECESSED EQUIPMENT (E.G. FIRE EXTINGUISHERS) SHALLBE LINED WITH 1 LAYER 5/8" GWP(3) SEE DOOR DETAILS FOR GASKET REQUIREMENTS(4) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHINDTUB ENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D3273 WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
1 HOUR
GA WP 3380
STC: 52
••
•
••••
B3CORRIDOR WALL
2 LAYERS 5/8" TYPE 'X' GWB6" STEEL STUDS @ 16" O.C.R-19 BATT INSULATION FOR SOUND ATTENUATION
OR R-21 WHEN ADJACENT TO UNHEATED SPACEWRAP PLUMBING PIPE WITH SOUND ATTENUATION BATT1 LAYER 5/8" TYPE 'X' GWB
NOTE:(1) ON CONCRETE SLAB, FIRST LAYER GWB ON EACH SIDE OF STUDTO BE CAULKED, TOP AND BOTTOM USING RESILIENT CAULK(2) RECESSED EQUIPMENT (E.G. FIRE EXTINGUISHERS) SHALL BELINED WITH 1 LAYER 5/8" GWP(3) SEE DOOR DETAILS FOR GASKET REQUIREMENTS(4) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
1 HOUR
GA WP 1052
STC: 50-54•••
••
A6CORRIDOR WALLWITH PLUMBING
5/8" TYPE 'X' GWB5/8" TYPE 'X' GWB OR 1/2" PLYWOOD SHEATHING ONLY WHEREINDICATED BY STRUCTURAL2X4 STAGGERED WOOD STUD (PER STRUCTURAL) ONCOMMON 2X6 PLATEROCK WOOL BATT INSULATION AT 10'-0" MAX. INTERVALWRAP PLUMBING PIPE WITH SOUND ATTENUATION BATTR-19 BATT INSULATION FOR SOUND ATTENUATION5/8" TYPE 'X' GWB
NOTE:(1) ON CONCRETE SLAB, FIRST LAYER GWB ON EACH SIDE OFSTUD TO BE CAULKED, TOP AND BOTTOM USING RESILIENTCAULK(2) RECESSED EQUIPMENT (E.G. FIRE EXTINGUISHERS) SHALLBE LINED WITH 1 LAYER 5/8" GWP(3) SEE DOOR DETAILS FOR GASKET REQUIREMENTS(4) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHINDTUB ENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D3273 WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
••
•
••••
B6CORRIDOR WALLWITH PLUMBING
8 1/
2"
1 HOUR
GA WP 3380
STC: 50
7 1/
4"8"
*TYPICAL PARTY WALL IS 2x4 STUDS @ 16" O.C.EACH FACE, STAGGERED
*THE FOLLOWING WALLS ARE TO BE DOUBLE 2x4 STUDS @ 16" O.C.EACH FACE, STAGGERED
GRIDS A.6, C, D AND E.3 ON THE 3RD, 4TH AND 5TH LEVELSGRIDS 1.7 BETWEEN A AND C.4 ON THE 3RD AND 4TH LEVELSGRIDS 2.1 AND 2.5 BETWEEN A AND C.4 ON THE 3RD LEVELGRIDS 1.6, 2, 2.4 AND 2.9 BETWEEN C.7 AND E.8 ON THE 3RD
AND 4TH LEVEL
2 LAYER 5/8" TYPE 'X' GWB8" STEEL STUDS @ 16" O.C.R-19 BATT INSULATION FOR SOUND ATTENUATION
OR R-21 WHEN ADJACENT TO UNHEATED SPACEWRAP PLUMBING PIPE WITH SOUND ATTENUATION BATT1 LAYER 5/8" TYPE 'X' GWB
NOTE:(1) ON CONCRETE SLAB, FIRST LAYER GWB ON EACH SIDE OFSTUD TO BE CAULKED, TOP AND BOTTOM USING RESILIENTCAULK(2) RECESSED EQUIPMENT (E.G. FIRE EXTINGUISHERS) SHALL BELINED WITH 1 LAYER 5/8" GWP(3) SEE DOOR DETAILS FOR GASKET REQUIREMENTS(4) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHINDTUB ENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D3273 WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
1 HOUR
GA WP 1052
STC: 50-54(WITH BATT INSUL)
•••
••
10"
0' - 8"
4 3/
4"6
3/4"
7 1/
4"
9 3/
4"
B7FIRE BARRIER
(CLOSURE)SHAFT WALL
1-1/2" RIGID INSULATION2 1/2" STEEL C-T STUDS @ 24" O.C.1"x24" TYPE 'X' GYPSUM CORE BOARD
NOTE:(1) ASSEMBLY PER ELEVATOR SPECS WHEN LOCATED ATELEVATOR SHAFT
2 HOUR
GA WP 7051PROPRIETARY
STC: 50-54•••
8"
16"
••••
8"
2 LAYERS 1/2" TYPE 'X' GWB6" STEEL STUDS @ 16" O.C.R-19 BATT INSULATION FOR SOUND ATTENUATION
WRAP PLUMBING PIPE WITH SOUND ATTENUATION BATT1/2" RESILIENT CHANNEL1 LAYER 1/2" TYPE 'X' GWB
NOTE:(1) ON CONCRETE SLAB, FIRST LAYER GWB ON EACH SIDE OFSTUD TO BE CAULKED, TOP AND BOTTOM USING RESILIENT CAULK(2) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHINDTUB ENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D3273 WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
•••
••
WALL PER PLAN
B5
3/4" TYPE 'X' GYPSUM CORE BOARD1-1/2" RIGID INSULATION4" STEEL C-T STUDS @ 24" O.C.1"x24" TYPE 'X' GYPSUM CORE BOARD
NOTE:(1) ASSEMBLY PER ELEVATOR SPECS WHEN LOCATED ATELEVATOR SHAFT
2 HOUR
GA WP 7053PROPRIETARY
STC: 50-54••••
4 3/
4"
FIRE BARRIER(SHAFT WALL)
ATSTAIR/ELEVATOR
(NO PENETRATIONS)
B8FIRE BARRIER(SHAFT WALL)
ATSTAIR/ELEVATOR
(NO PENETRATIONS)
2 LAYERS 5/8" TYPE 'X' GWBADD 1/2" PLYWOOD ONLY WHERE INDICATED PER STRUCTURAL6" STEEL STUDS @ 16" O.C.ROCK WOOL FIRE-BLOCK AT 10'-0" MAX. INTERVAL.R-19 SOUND ATTENUATION BATT INSULATION2 LAYERS 5/8" TYPE 'X' GWB
2 HOUR
GA WP 1522
STC: 55-59••••••
9"
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A10.0
115205.22.2013
AMMG1152_TRIAD 12TH
INTERIORASSEMBLIES
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
WALL TYPE ASSEMBLIES: EXTERIOR
WALL TYPE WALL DETAIL ASSEMBLY DESCRIPTION FIRE SOUND THERMAL
RATING
E3EXTERIOR
WALLW/ SIDINGAT STAIR(TYPE VA)
2 HOURS
GA WP 8415
R-21
SIDING PER ELEVATIONSP.T. VERTICAL WOOD FURRING STRIPSWEATHER BARRIER (PER SPEC)2 LAYERS OF 5/8" TYPE X GWB SHEATHING1 LAYER OF 1/2" PLYWOOD SHEATHING2x6 WOOD STUD WALL (PER STRUCTURAL)R-21 BATT INSULATIONADD 1/2" RESILIENT CHANNEL TO APARTMENT SIDE ONLY @ UNIT WALLLOCATIONS2 LAYERS OF 5/8" TYPE 'X' GWBPVA PRIMER
NOTE:(1) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273 WITHSCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
••••••••
••
WALL TYPE ASSEMBLIES: CONCRETE
WALL TYPE WALL DETAIL ASSEMBLY DESCRIPTION FIRE SOUND THERMAL
RATING
C1CAST-IN-PLACE
CONCRETE WALL
CAST-IN-PLACE CONCRETE (PER STRUCT)
NOTE:(1) BELOW GRADE LOCATIONS: PROVIDE CONT. W/P MEMBRANE (PERSPEC)(2) BELOW GRADE LOCATIONS: PROVIDE DRAINMAT (PER W/PCONSULTANT) LAP OVER FILTER FABRIC(3) EXPOSED EXT. LOCATIONS: PROVIDE ANTI GRAFFITI COATING ORACRYLIC TOPCOAT FINISH
•
PER
STR
UC
TUR
AL
C2CONCRETE
WALL W/ METALFURRING
6"PE
R S
TRU
CTU
RAL
WATERPROOFING (PER SPEC)ANTI GRAFFITI COATING OR ACRYLIC TOPCOAT AT EXPOSEDLOCATIONSSHOTCRETE WALL (PER STRUCTURAL)2" (R-10) XPS FOAM INSULATION3-5/8" MIN STEEL STUDS @ 24" O.C. (SIZE STUD PER PLUMBING PIPE)R-13 BATT INSULATION MINWRAP PLUMBING PIPE WITH SOUND ATTENUATION BATT5/8" GWBPVA PRIMER
••
•••••••
E4EXTERIOR
WALLW/ SIDING(TYPE 1A)
1 HOURRATED FROMBOTH SIDES
GA WP 8122
R-21
SIDING PER ELEVATIONS (METAL PANEL OR FIBER CEMENT PANEL)3/4" CI-GIRT WITH THERMALLY ISOLATED FASTENERS2" RIGID SHEATHING INSULATION W/ INTEGRAL WATER RESISTIVEFACER5/8" TYPE 'X' GWB SHEATHING6" STEEL STUD @ 16" O.C. WALL (PER STRUCT)PROVIDE HORIZONTAL BLOCKING SUPPORT FOR FURRINGR-21 BATT NISULATION5/8" TYPE 'X' GWBPVA PRIMER
NOTE:(1) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273WITH SCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
C3CMUWALL
GROUT-FILLED CONCRETE MASONRY UNIT (PER STRUCT)
NOTE:(1) BELOW GRADE LOCATIONS: PROVIDE CONT. W/P MEMBRANE(PER SPEC)
(2) EXPOSED EXT. LOCATIONS: PROVIDE ANTI GRAFFITI COATINGOR ACRYLIC TOPCOAT FINISH
•
C4CMU WALLW/ METALFURRING
GROUT-FILLED CONCRETE MASONRY UNIT (PER STRUCT)2" (R-10) XPS FOAM INSULATION3 5/8" MIN. STEEL STUDS @ 24" O.C. (SIZE STUD PER PLUMBING PIPE)R-13 BATT INSULATION MIN.WRAP PLUMBING PIPE WITH SOUND ATTENUATION BATT5/8" GWBPVA PRIMER
NOTE:(1) BELOW GRADE LOCATIONS: PROVIDE CONT. W/P MEMBRANE(PER SPEC)
(2) EXPOSED EXT. LOCATIONS: PROVIDE ANTI GRAFFITI COATINGOR ACRYLIC TOPCOAT FINISH
••••
••
E1EXTERIOR
WALLW/ SIDING(TYPE VA)
1 HOURRATED FROMBOTH SIDES
GA WP 8105
SIDING PER ELEVATIONS (METAL PANEL OR FIBER CEMENT PANEL)P.T. VERTICAL WOOD FURRING STRIPSWRB (PER SPEC)1 LAYER 5/8" TYPE 'X' GWB SHEATHING1 LAYER OF 1/2" PLYWOOD SHEATHING2x6 WOOD STUDS (PER STRUCTURAL)R-21 BATT INSULATION, FRICTION FIT1 LAYER OF 5/8" TYPE 'X' GWBPVA PRIMER
NOTE:(1) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273 WITHSCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
R-21•••••••••
R-21
E5EXTERIOR
WALLW/ SIDINGAT STAIR(TYPE 1A)
2 HOURS
GA WP 8202
E2EXTERIOR
WALLW/ SIDING(TYPE VA)
1 HOURRATED FROMTHE INSIDEONLY
IN ACCORDANCE W/SBC 705.5SBC TABLE 720.1(2) -ITEM 16-1.2
SIDING PER ELEVATIONS (METAL PANEL OR FIBER CEMENT PANEL)P.T. VERTICAL WOOD FURRING STRIPSWEATHER BARRIER (PER SPEC)1 LAYER OF 1/2" PLYWOOD SHEATHING2x6 WOOD STUDS (PER STRUCTURAL)R-21 BATT INSULATION, FRICTION FIT1 LAYER OF 5/8" TYPE 'X' GWBPVA PRIMER
NOTE:(1) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273 WITHSCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS(2) E2 CAN BE REPLACED BY E1 AT THE DISCRETION OF THECONTRACTOR EXCEPT AT SHEAR WALL LOCATIONS AS INDICATEDPER STRUCTURAL
••••••••
R-21
4 HOUR = 7.0" MIN.3 HOUR = 6.2" MIN.2 HOUR = 5.0" MIN.1 HOUR = 3.5" MIN.
SBC 2009TABLE 720.1(2)ITEM 4-1.1
4 HOUR = 7.0" MIN.3 HOUR = 6.2" MIN.2 HOUR = 5.0" MIN.1 HOUR = 3.5" MIN.
SBC 2009TABLE 720.1(2)ITEM 4-1.1
••••••••••
SIDING PER ELEVATIONS3/4" CI-GIRT WITH THERMALLY ISOLATED FASTENERS2" RIGID SHEATHING INSULATION W/ INTEGRAL WATER RESISTIVE FACER1 LAYER 5/8" FIREGUARD DENSGLASS SHEATHING1 LAYER 5/8" TYPE 'X' GWB6" STEEL STUD @ 16" O.C. WALL (PER STRUCT)PROVIDE HORIZONTAL BLOCKING SUPPORT FOR FURRINGR-21 BATT NISULATION2 LAYERS OF 5/8" TYPE 'X' GWBPVA PRIMER
NOTE:(1) PROVIDE SOLID NON-PAPER FACED BACKERBOARD BEHIND TUBENCLOSURES OR PAPER-FACED GWB THAT MEETS ASTM D 3273 WITHSCORE OF 10 BEHIND FIBERGLASS TUB SURROUNDS
••••••••••
0' -
8 1/
2"0'
- 9
1/4"
0' -
10 3
/4"
7 1/
4"
GRID
GRID
GRID
GRID
GRID
R-21+R-10
R-21+R-10
R-10+R-13
R-10+R-13
3 HOUR = 5.3" MIN.2 HOUR = 4.2" MIN.1 HOUR = 2.8" MIN.
SBC 2009TABLE 720.1(2)ITEM 3-1.4
3 HOUR = 5.3" MIN.2 HOUR = 4.2" MIN.1 HOUR = 2.8" MIN.
SBC 2009TABLE 720.1(2)ITEM 3-1.4
STR
UC
TUR
AL
PER
0' -
6 3/
4"
STC 60
.
.
C5CONCRETE
WALL W/ RIGIDINSUL PE
R S
TRU
CTU
RAL
WATERPROOFING (PER SPEC)ANTI GRAFFITI COATING OR ACRYLIC TOPCOAT AT EXPOSEDLOCATIONSCONCRETE WALL (PER STRUCTURAL)2" (R-10) XPS FOAM INSULATION W/Z-FURRING5/8" GWBPVA PRIMER
••
••••
4 HOUR = 7.0" MIN.3 HOUR = 6.2" MIN.2 HOUR = 5.0" MIN.1 HOUR = 3.5" MIN.
SBC 2009TABLE 720.1(2)ITEM 4-1.1
R-10
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A10.1
115205.22.2013
AMMG1152_TRIAD 12TH
EXTERIORASSEMBLIES
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
FLOOR/CEILING DETAIL
F1FLOOR
ASSEMBLY(TYPE VA)
FINISH FLOORINGHARD SURFACE AREAS: 1" CEMENTITIOUS UNDERLAYMENTOVER 1/4" ACOUSTIC TREATMENT("ACOUSTI-MAT II" OR "QUIET QURL 55-025")
(OR)CARPETED AREAS: CARPET & PAD OVER1-1/4" CEMENTITIOUS UNDERLAYMENT
PLYWOOD SHEATHING (PER STRUCTURAL)TJI JOIST OR WOOD STUD (PER STRUCTURAL)3 1/2" (R-11) ACOUSTICAL BATT INSULATION1/2" RESILIENT CHANNEL 16" O.C. INSTALLED PERPENDICULAR TOFRAMING MEMBERS2 LAYERS 5/8" TYPE 'X' GWB
WALL ASSEMBLIES: TYPE VA, INTERIORWALL TYPE ASSEMBLY DESCRIPTION FIRE SOUND THERMAL
RATING
••
•
••
•
F4FLOOR/CEILING
W/ SOFFIT
(HEATED OVERHEATED)
FLOORINGCONCRETE SLAB (PER STRUCTURAL)STEEL STUDSINSULATE AT PIPE LOCATIONS1/2" RESILIENT CHANNEL5/8" TYPE 'X' GWB
PER
STR
UC
TVA
RIE
S
••••••
F3CONCRETE FLOORSLAB OVER LIVING
UNIT
(HEATED OVERHEATED)
FINISH FLOORING (PER PLAN):(NOTE: HARD SURFACE AREAS; PROVIDE VC 300 PADUNDERLAYMENT; CARPETED AREAS NO ADDITIONAL MITIGATIONREQUIRED)POST-TENSIONED CONCRETE SLAB (PER STRUCTURAL)
PER
STR
UC
TVA
RIE
S
•
•
F2 FINISH FLOORING (PER PLAN)CONCRETE SLAB (PER STRUCTURAL)
PER
STR
UC
TVA
RIE
S
••
EXPOSEDCONCRETE
FLOOR SLAB
F5FLOOR
ASSEMBLY(TYPE 1A)
(HEATED OVERNON-HEATED)
F6CONCRETE
SLAB-ON-GRADE
FINISH FLOORING (PER PLAN)CONCRETE SLAB (PER STRUCTURAL)R-30 BLANKET INSULATION PER SBC SECTION 719.3VINYL FACED BATTS STICK-PINNED TO SLAB
NOTE:THIS ASSEMBLY TO BE USED AS CEILING CONDITION FOR THETENANT STORAGE (RM. B16), BICYCLE PARKING (RM. B06), ANDTHE REFUSE/RECYCLING AREA (RM. 114)
••••
•
FINISH FLOORING (PER PLAN)CONCRETE SLAB-ON-GRADE (PER STRUCTURAL)2" XPS RIGID INSULATION FOR 24" INBOARD OF PERIMETERFREE DRAINING GRANULAR FILL (PER GEOTECH)COMPACTED NATIVE BEARING SOIL
NOTE:(1) PROVIDE VAPOR BARRIER W/ FULLY TAPED JOINTS AT ALLSLAB-ON-GRADE LOCATIONS
•••
1 HOUR
FC5111 @ JOISTS
FC5120 @ STUDS
STC: 50-54
3 HOUR
SBC 2009TABLE 720.1(1)ITEM 4-1.1&TABLE 720.1(3)ITEM 1-1.1
3 HOUR
SBC 2009TABLE 720.1(1)ITEM 4-1.1&TABLE 720.1(3)ITEM 1-1.1
3 HOUR
SBC 2006TABLE 720.1(3)ITEM 6-4.1
3 HOUR
SBC 2009TABLE 720.1(1)ITEM 4-1.1&TABLE 720.1(3)ITEM 1-1.1
R-30
1' -
1 1/
4"
UNIT
UNIT
0' -
7"
4"
UNIT
PER
STR
UC
TVA
RIE
S
UNIT
9 1/
2"
ROOF ASSEMBLIES:
ROOF TYPE ROOF DETAIL ASSEMBLY DESCRIPTION FIRE SOUND THERMAL
RATING
R2TYP ROOF
ASSMBW/ ROOF
DECK(TYPE VA)
R1TYP ROOF
ASSMB(TYPE VA)
1 HOUR
ESR-1153ASSEMBLY B
•••••
•
R-48
1 HOUR
ESR-1153ASSEMBLY B
R-11
R-11
R-10
UNIT
UNIT
NON-HEATED
PRECAST CONCRETE PAVERS OR WOOD DECKING ON PEDESTALSHORIZONTAL WATERPROOFING SYSTEM (PER SPEC)CONCRETE SLAB (PER STRUCTURAL) SLOPED MIN. 3/8" PER FOOT TO DRAIN
3 HOUR
SBC 2009TABLE 720.1(1)ITEM 4-1.1&TABLE 720.1(3)ITEM 1-1.1F7
CONCRETEPAVERS ONW/P SLAB
PATIO
PER
STR
UC
TUR
AL
SLOPE MIN. 3/8" PER FT.
•••
CARPET VINYL FLOORING
STC: 50
STC: 50
STC: 50
STC: 50
APPROVED ROOFING SYSTEM (PER SPEC)8" POLYISO RIGID INSULATION (R-48)SHEATHING (PER STRUCTURAL)SLOPED ROOF TRUSS OR TJI (PER STRUCTURAL)1/2" RESILIENT CHANNEL (OVER 7TH FLOOR ONLY, NOT REQ'D FORPENTHOUSE ROOF)(2) LAYERS 5/8" TYPE X GWB
WOOD DECKINGPRESSURE TREATED WOOD SLEEPERS(NOTCH TO ALLOW FOR DRAINAGE)PROTECTION MATAPPROVED ROOFING SYSTEM (PER SPEC)8" POLYISO RIGID INSULATION (R-48)SHEATHING (PER STRUCTURAL)SLOPED ROOF TRUSS (PER STRUCTURAL)2.5" BATT INSULATION PER ACOUSTICAL REQUIREMENTSRSIC-1 CLIP OR GENIECLIP(2) LAYERS 5/8" TYPE X GWB
••
••••••••
R3TYP ROOF
ASSMBW/
OVERFRAMING(TYPE VA)
FINISH FLOORINGHARD SURFACE AREAS: 1" CEMENTITIOUS
UNDERLAYMENTOVER 1/4" ACOUSTIC TREATMENT("ACOUSTI-MAT II" OR "QUIET QURL 55-025")
(OR)CARPETED AREAS: CARPET & PAD OVER1-1/4" CEMENTITIOUS UNDERLAYMENT
SHEATHING (PER STRUCTURAL)WOOD JOIST OVERFRAMING (PER STRUCTURAL)SHEATHING (PER STRUCTURAL)SLOPED ROOF TRUSS (PER STRUCTURAL)2.5" BATT INSULATION PER ACOUSTICAL REQUIREMENTSRSIC-1 CLIP OR GENIECLIP(2) LAYERS 5/8" TYPE X GWB
•
•
•••••••
1 HOUR
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A10.2
115205.22.2013
AMMG1152_TRIAD 12TH
ROOF + FLOORASSEMBLIES
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
3 BP CORRECTION 02.28.13
TYPE APANEL
TYPE BDOUBLE PANEL
TYPE CBI-FOLD
TYPE DGLAZING
SG
DOOR TYPE SCHEDULE
DOOR MATERIAL KEY
MATERIAL/FINISHABRVALUMINUM W/ TEMPERED GLASSALUM/GLANODIZEDANODALUMINUMALUMCLEAR FINISHCLFACTORYFACFIBERGLASSFGTEMPERED GLASSGLHOLLOW CORE WOODHCWLOUVERLVRMETALMTLPAINTPTSOLID CORE WOODSCWSAFETY GLAZING/ TEMPERED GLASSSGSTAINSTSTOREFRONTSTFVINYLVVINYL W/ TEMPERED GLASSV/GLWOODWDWOOD W/ TEMPERED GLASSWD/GL
REQUIREMENT#PASSAGE HARDWARE1PRIVACY HARDWARE2
BARRIER-FREE HARDWARE9
LOUVER AT LAUNDRY/UTILITY CLOSETS13
DOOR STOP21VIEWPORT, 60" AFF AND MEETING THE REQUIREMENTS OF 715.3.322DEAD BOLT, 1/2" THROW MIN. W/ MIN. 1/4" PENETRATION IN STRIKE JAMB23FLUSH BOLTS
3
CLOSER
4
SMOKE AND DRAFT CONTROL
5
WEATHERSTRIPPING
29
ELECTRONIC STRIKE CONNECTED TO INTERCOM
24
SECURITY FOB HARDWARE
16
INSULATED EXTERIOR DOOR
30
LOUVER IN DOOR
26
PANIC HARDWARE PER SBC 1008.1.9
32
AUTOMATIC DOOR OPERATOR FOR BARRIER-FREE ACCESS
7
UNDERCUT DOOR FOR VENTILATION
8
DOOR NOTES KEY
SELF LOCKING
25
EXTERIOR SLIDER HARDWARE
12
HOSPITAL HINGE
28
180 DEGREE SWING
11
STC VALUE TO MATCH ADJACENT WINDOW
14
BARN DOOR HARDWAREBI-FOLD HARDWAREBYPASS HARDWARE
EMERGENCY EXIT ONLY - ALARM WILL SOUND
SECURITY CARD HARDWARE
20
10
19
15
27
17
33
31
EXTERIOR SPRING CLOSER ALLOWING 180 DEGREE DOUBLE SWING
CALL BOX CONNECTED TO INTERCOM
SMOKE ACTIVATED
6 DUMMY HARDWARE
SPRING HINGE18
343536
ROLL DOWN FIRE DOOR HARDWAREOPEN GRATE FOR VENTILATIONSOLID SECTIONAL SEGMENTS
37 CHAIN-LINK FENCE DOOR
DOOR NOTES
TYPICAL DOOR JAMBS IN CORRIDORS SHALL BE OFFSET 6" FROM THE WALL ONTHE HINGE SIDE. TYPICAL DOOR JAMBS FOR PASSAGE DOORS SHALL BE OFFSETA MINIMUM OF 3" FROM THE WALLS ON BOTH SIDES. REFER TO ACCESSIBILITYNOTES FOR DOOR CLEARANCE REQUIREMENTS.
THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3/4" IN HEIGHT FOR SLIDINGDOORS SERVING DWELLING UNITS OR 1/2" FOR OTHER DOORS. RAISEDTHRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1/4" AT DOORWAYSSHALL BE BEVELED WITH A SLOPE NOT GREATER THAN 50 PERCENT. SBC1008.1.7.
EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDEWITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. DOORHANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL NOTREQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TOOPERATE. THEY SHALL BE INSTALLED 34" MIN. TO 48" MAX. ABOVE FINISHEDFLOOR. SBC 1008.1.9.1 & SBC 1008.1.9.2
FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THEBUILDING OFFICIAL. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPENDOORS OTHER THAN FIRE DOORS SHALL BE 5.0 POUNDS FOR INTERIOR HINGEDDOORS AND SLIDING OR FOLDING DOORS. EXTERIOR DOORS REQUIRING ACLOSING PRESSURE GREATER THAN 8.5 POUNDS SHALL BE POWER OPERATEDWITHIN THE ACCESSIBILE ROUTE OF TRAVEL. SBC 1101.2.3. ICC A117.1 SECTION404.2.8
BUILDING ENTRANCE DOORS SHALL BE SELF-CLOSING, SELF-LOCKING ANDEQUIPPED WITH A DEAD-LOCKING LATCH BOLT WITH AT LEAST A 1/2" THROWWHICH SHALL PENETRATE THE STRIKER AT LEAST 1/4". SBC 420.6.1.2.
EVERY ENTRANCE DOOR TO A HOUSING UNIT SHALL HAVE A DEAD BOLT OR DEAD-LOCKING LATCH BOLT WITH AT LEAST A 1/2" THROW WHICH SHALL PENETRATETHE STRIKER AT LEAST 1/4". SBC 420.6.1.4.
EVERY ENTRANCE DOOR TO A HOUSING UNIT OTHER THAN TRANSPARENTDOORS, SHALL HAVE A VISITOR-OBSERVATION PORT WHICH SHALL NOT IMPAIRTHE FIRE RESISTANCE OF THE DOOR. OBSERVATION PORTS SHALL BEINSTALLED BETWEEN 54" AND 66" ABOVE THE FLOOR. SBC 420.6.1.5.
VIEWPORTS SHALL BE INSTALLED WITH A HOLE NO LARGER THAN 1" IN DIAMETERTHROUGH THE DOOR, HAVE AT LEAST A 1/4" THICK GLASS DISK, AND HAVE A METALHOLDER THAT WILL NOT MELT OUT WHEN SUBJECT TO TEMPERATURES OF 1700DEGREES F. SBC 715.4.3, EXCEPTION 1.
FIRE DOOR ASSEMBLIES LOCATED IN CORRIDOR WALLS SHALL MEET THEREQUIREMENTS OF SBC 715.4.3. AN ARTIFICIAL BOTTOM SEAL SHALL BEINSTALLED ACROSS THE FULL WIDTH OF THE BOTTOM OF THE DOOR ASSEMBLYIN ORDER TO MEET THE REQUIREMENTS FOR A SMOKE-AND-DRAFT-CONTROLDOOR ASSEMBLY PER UL 1784.
ALL FIRE DOORS SHALL BE SELF-CLOSING. DOORS INSTALLED ACROSSCORRIDORS WHICH ARE PROVIDED WITH HOLD-OPEN DEVICES SHALL BEAUTOMATIC-CLOSING BY THE ACTUATION OF SMOKE DETECTORS. SBC 715.4.8 &SBC 715.4.8.3. NFPA 80
DOORS TO STORAGE, MAINTENANCE AND BUILDING SERVICE ROOMS SHALL BESELF-CLOSING AND SELF-LOCKING. SBC 419.5.1.6.
ALL FIRE-RATED DOORS AND FRAMES SHALL BEAR A LABEL FROM A RECOGNIZEDRATING AGENCY.
THE CONTRACTOR SHALL COORDINATE ALL TRANSFORMER VAULT ACCESSDOOR AND HARDWARE REQUIREMENTS WITH THE CITY OF SEATTLE.
ALL GLAZING IN DOORS SHALL BE SAFETY GLAZING. SBC 2406.3.
REFER TO WINDOW AND GLAZING NOTES, SHEET A10.3, FOR ADDITIONALREQUIREMENTS PERTAINING TO GLAZED DOORS.
UNGLAZED EXTERIOR DOORS SHALL HAVE A U-VALUE AS STATED ON THE ENERGYCODE COMPLIANCE SHEETS. THE DOOR SHALL BEAR AN NFRC LABELIDENTIFYING THE U-VALUE. IF THE DOOR DOES NOT HAVE AN NFRC LABEL, IT WILLBE ASSUMED THAT THE DOOR HAS A DEFAULT U-VALUE AS STATED IN SECTION502.1.5.2 OF THE SEATTLE ENERGY CODE.
REFER TO EGRESS NOTES, SHEET A0.01, FOR EXIT SIGNAGE REQUIREMENTS ATDOORS.
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
17)
TYPE APANEL
TYPE BDOUBLE PANEL/
BI-FOLD
DOOR FRAME SCHEDULE
GENERAL DOOR DETAIL NOTES:
• ALL DOORS LEADING FROM AUNIT TO THE EXTERIOR (OR)FROM A UNIT TO A CORRIDORWILL HAVE WEATHERSTRIPPINGAND SWEEPS AT THETHRESHOLD.
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A10.3
115205.22.2013
SLMG1152_TRIAD 12TH
DOOR SCHEDULE
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL
DOOR SCHEDULEDOORTAG
DOOR FRAME DETAIL FIRERATING LOCATION INT/EXT NOTESTYPE MATL FINISH WIDTH HEIGHT THICK TYPE MATL FINISH HEAD JAMB THRSHLD
LEVEL B1001 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 12/A9.9 11/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28002 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 20 MIN. SPRINKLER ROOM INT 1,16,20,21,30003 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 20 MIN. TELECOM ROOM INT 1,16,20,21,30004 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 20 MIN. BICYCLE PARKING INT 1,9,21,30005 D ALUM/GLASS ANOD/FAC 3' - 0" 7' - 0" 2" A ALUM ANOD 20 MIN. CORRIDOR/EXIT EXT 1,9,16,20,21,23,25,26006 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 1 HR METER ROOM INT 1,16,20,21,28,30007 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 1 HR TENANT STORAGE INT008 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 1 HR METER ROOM INT 1,16,20,21,28,30009 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 20 MIN. TRANSFORMER VESTIBULE INT 1,16,20,21,30010 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28011 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 14/A9.9 3 HR TRANSFORMER VAULT INT 1,16,20,21,30012 A MTL PT 6' - 0" 8' - 0" 2" A MTL PT 8/A9.9 7/A9.9 3 HR TRANSFORMER ACCESS INT 1, 15,16,20,21,30
LEVEL 1100 D ALUM/GLASS ANOD/FAC 6' - 0" 7' - 0" 2" B ALUM ANOD - - MAIN ENTRY EXT 1,9,16,20,23,25,26101 D ALUM/GLASS ANOD/FAC 3' - 0" 7' - 0" 3/4" A ALUM ANOD - - ENTRY VESTIBULE INT102 D ALUM/GLASS ANOD/FAC 3' - 0" 7' - 0" 2" A ALUM ANOD - - LOBBY COURTYARD EXT 1,9,16,20,23,25,26103 A HCW FAC 3' - 0" 7' - 0" 2" A MTL PT 2/A9.9 1/A9.9 - - PUBLIC RESTROOM INT 1,2,9,14,21104 D ALUM/GLASS ANOD/FAC 3' - 0" 7' - 0" 2" A ALUM ANOD 12/A9.9 11/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28105 D ALUM/GLASS ANOD/FAC 3' - 0 1/4" 7' - 0" 2" A ALUM ANOD 20 MIN. LOBBY/CORRIDOR INT 1,9,16,20,21,25,26106 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 45 MIN. REFUSE/RECYCLING EXT 1,9,16,20,21,28,30107 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28108 - - FACTORY PT 4' - 0" 7' - 0" 2" - - FACTO
RYPT - - - - - - - - BIKE ENTRY GATE EXT SEE DETAIL 4/A9.11
LEVEL 2200 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 12/A9.9 11/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28201 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28
LEVEL 3300 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28301 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28
LEVEL 4400 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28401 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28402 A MTL PT 3' - 0" 6' - 8" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 20 MIN. TELECOM CLOSET INT 1,16,20,21,30
LEVEL 5500 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28501 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28
LEVEL 6600 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28601 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28
LEVEL 7700 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 90 MIN. STAIR A EXT 1,9,16,21,25,26,28701 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 10/A9.9 9/A9.9 14/A9.9 90 MIN. STAIR B EXT 1,9,16,21,25,26,28702 A MTL PT 3' - 0" 6' - 8" 2" A MTL PT 6/A9.9 5/A9.9 14/A9.9 - - TELECOM CLOSET INT 1,16,20,21,30
ROOF DECK800 E ALUM/GLASS ANOD/FAC 6' - 0" 7' - 0" 2" B ALUM ANOD - - ELEVATOR LOBBY EXT 1,9,16,21,23,24,25,26801 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT 2/A9.9 1/A9.9 14/A9.9 90 MIN. CONTROL ROOM INT 1,16,20,21,30802 A MTL PT 3' - 0" 7' - 0" 2" A MTL PT - - BOILER ROOM EXT 1,16,20,21,25,26
UNIT DOOR SCHEDULEDOORTAG
DOOR FRAME DETAIL FIRERATING LOCATION INT/EXT NOTESTYPE MODE MATL FINISH WIDTH HEIGHT THICK TYPE MATL FINISH HEAD JAMB THRESHOLD
U1 A SWING SCW PT 3' - 0" 6' - 8" 0' - 2" A MTL PT 6/A9.6 5/A9.6 9/A9.7 20 MIN. UNIT ENTRY INT 1,2,9,16,21,22,23,26,30
U2 A SWING HCW PT 3' - 0" 6' - 8" 0' - 2" A WD PT 2/A9.6 1/A9.6 - - - - BATH INT 1,2,9,14,21U3 A SWING HCW PT 3' - 0" 6' - 8" 0' - 2" A WD PT 2/A9.6 1/A9.6 - - - - CLOSET INT 6U4 C BI-FOLD HCW PT 4' - 0" 6' - 8" 0' - 2" B WD PT 4/A9.6 3/A9.6 - - - - CLOSET INT 4U5 D SWING VINYL/GLASS FAC 3' - 0" 7' - 0" 0' - 2" D VINYL FAC 8/A9.6 7/A9.6 9/A9.7 - - PATIO EXT 1,2,9,21,23,25,26
3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.13
7' -
2"
3' - 3" 1' - 4"
4' - 7"
SG
SG
5' -
2"2'
- 0"
SG
23' - 10"
SG SG SG SG
SG SG
1' -
7"5'
- 0"
2' -
2"
9' -
2"
SG
3' - 9" 3' - 9" 3' - 9" 3' - 9" 2' - 7" 6' - 3"
5"C
ON
C.
CU
RB
7' -
0"
SG
4' - 3 1/2" 1' - 7"
5' - 10 1/2"
.5'
- 1"
2' -
2"
7' -
3"
CO
NC
CU
RB
7' -
0"2'
- 4"
9' -
4"
2' -
0"5'
- 1"
2' -
3"
3' - 3 1/4" 1' - 7 1/4"
4' - 10 1/2"
SG
SG
SG
7' -
0"2'
- 4"
3' - 3" 1' - 3"
4' - 6"2'
- 0"
5' -
1"2'
- 3"
SG
SG
9' -
4"
WINDOW NOTES
ALL WINDOW ELEVATIONS DRAWN IN THESE SCHEDULES ARE VIEWED FROM THE EXTERIOR.
EMERGENCY EGRESS AND RESCUE WINDOWS ("EGRESS WINDOWS") ARE NOT REQUIRED FOR R-2OCCUPANCIES WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM MEETING THE REQUIREMENTS OF NFPA 13.SBC 1026.1, EXCEPTION 1.
OPENABLE WINDOWS SHALL HAVE OPERABLE INSIDE LATCHING DEVICES PER SBC 419.5.1.8.
SAFETY GLAZING (S.G.) SHALL BE PROVIDED IN HAZARDOUS LOCATIONS, INCLUDING THE FOLLOWING LOCATIONSAS SPECIFIED IN SBC 2406.3. EACH PANE OF SAFETY GLAZING SHALL BE IDENTIFIED WITH A PERMANENT LABEL.
A) GLAZING IN ALL DOORS, AND WITHIN 24" OF EITHER VERTICAL EDGE OF A DOOR.B) GLAZING PANELS LARGER THAN 9 SF WITH SILLS LESS THAN 18" ABOVE THE FINISHED FLOOR AND A
TOP EDGE GREATER THAN 36" ABOVE THE FINISHED FLOOR.C) GLAZING PANELS WITH SILLS LESS THAN 60" ABOVE THE STANDING SURFACE OF A BATH TUB OR
SHOWER.D) GLAZING IN ALL BATH AND SHOWER DOORS AND ENCLOSURES.E) GLAZING IN ALL GUARDS AND RAILINGS.F) GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36" HORIZONTALLY OF A
WALKING SURFACEG) GLAZING WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION.
WINDOWS SHALL BE DESIGNED, MANUFACTURED, AND INSTALLED TO WITHSTAND WIND EFFECTS AS DESCRIBEDIN SBC 1609.
WINDOWS ARE SHOWN AT ACTUAL DIMENSION UNLESS NOTED OTHERWISE. CONTRACTOR SHALL PLAN FORROUGH OPENINGS ACCORDINGLY.
THE GLAZING U-FACTOR SHALL BE U=0.29 TO U-0.32 IN THE RESIDENTIAL WOOD-FRAMED (TYPE V) PORTION OFTHE BUILDING. REFER TO ENERGY CODE NOTES, SHEET A0.30, FOR MORE INFORMATION ON THE AVERAGE U-VALUE.
ALL RESIDENTIAL VINYL WINDOWS SHALL BE INSTALLED WITH A FLEXIBLE MEMBRANE FLASHING PER DETAILS ONSHEET A9.01. SEE DETAILS 1/A9.1, 5-6/A9.1 AND 9/A9.1 FOR TYPICAL HEAD, SILL, & JAMB INSTALLATIONS AT METALSIDING & PHENOLIC RESIN PANELS.
ALL WINDOWS AND GLAZED DOORS SHALL BE NFRC CERTIFIED AND LABELED.
ALL WINDOWS ARE FIXED PANE OR HAVE CASEMENT OR AWNING HARDWARE PER SCHEDULE. HARDWARE ANDENVIRONMENTAL CONTROLS SHALL MEET THE REQUIREMENTS OF ICC/ANSI A117.1-2003 SECTION 1004.9 FOR'TYPE B' UNITS AND 1003.9 FOR 'TYPE A' UNITS.
ALL WINDOWS SHALL BE INSTALLED WITH A FLEXIBLE MEMBRANE FLASHING.
DOORS SHOWN ON THIS SCHEDULE BY DOOR MANUFACTURER AND NOT PART OF THE WINDOW.
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
LOUVER & SCREEN DIMENSIONS ARE FOR ROUGH OPENINGS. CONTRACTOR TO FIELD VERIFYDIMENSION PRIOR TO MANUFACTURING.
CONTRACTOR TO VERIFY LOUVER & SCREEN DIMENSIONS WITH MECHANICAL SUBCONTRACTORPRIOR TO CONSTRUCTION. IF DIMENSIONAL REQUIREMENTS VARY, CONTRACTOR SHALL NOTIFYARCHITECT PRIOR TO PROCEEDING.
1)
2)
GRILLS, SCREENS & LOUVERS NOTES:
A
7.5 SF
RESIDENTIAL VINYL SCHEDULE
B
17.5 SF
D
26 SF
C
12.5 SF
E.1
32.5 SF
I
51 SF
J
63 SF
H
56 SF
4' -
10"
3' -
0"
7' -
10"
2' - 6"
4' -
10"
3' -
0"
7' -
10"
5' - 10"
6' -
10"
3' -
0"3'
- 10
"
4' - 9"
SG 2' -
2"4'
- 10
"
7' -
10"
3' -
0"4'
- 10
"
3' - 0" 5' - 0"
8' - 0"
7' -
10" 4'
- 10
"3'
- 0"
3' - 0" 3' - 6"
6' - 6"
3' -
7"1'
- 11
"2'
- 5"
7' -
11"
3' - 0" 3' - 0"
7' -
10"
3' - 0" 5' - 0"
8' - 0"6' - 0"
L
212.35 SF(MAIN ENTRY)
N
80.12 SF(ENTRY VESTIBULE - SOUTH)
SG SGSG SG SG SG
4' -
10"
2' -
2"
7' -
10"
3' - 0" 3' - 6"
6' - 6"
G
45.5 SF
M
40.34 SF(MAIN ENTRY)
SG SG
RESIDENTIAL STOREFRONT SCHEDULE
SG SG
K
47 SF
7' -
10"
EQ EQ
6' - 0"
SG
U4
3' - 4"
100 101
6' - 0"
3' - 0" 3' - 0"
2' -
2"4'
- 10
"
7' -
10"
F
42 SF
10"
10"
10"
SG SG
R
32.86 SF(BIKE ENTRY)
P
45.89 SF(CORRIDOR/LOBBY)
Q
42 SF(STAIR A ENTRY)
S
51 SF(ELEVATOR
PENTHOUSE)
T
27 SF(ELEVATOR
PENTHOUSE)
O
84.39 SF(ENTRY VESTIBULE - WEST)
006104105
2' -
2"5'
- 0"
7' -
2"
2' - 6" 2"
4' - 6"
3' -
0"3'
- 10
"
6' -
10"
SG
E.2
30.75 SF
SG
U
27 SF(LOBBY)
4' -
6"1'
- 6"
7' - 4"
2' -
0"6'
- 0"
8' -
0"
3' - 0" 5' - 6"
1' -
10 1
/4"
2' -
0"6'
- 0"
8' -
0"
4' - 6"
1' -
10"
2' -
1"5'
- 0"
2' -
1"
9' -
2"
7' -
0"
3' - 3" 3' - 9" 1' - 4 1/2"
SG SG
SG
1' - 4" 3' - 9" 3' - 9"
8' - 10"
9' -
2"
1' -
10"
5' -
2"2'
- 2"
SG SGSG
NICHOLSON KOVALCHICK ARCHITECTS
310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154
www.nkarch.com
2013 NICHOLSON KOVALCHICK ARCHITECTS PSC
FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:
REVISIONS
ISSUANCE
#
A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13
A10.4
115205.22.2013
SLMG1152_TRIAD 12TH
WINDOW SCHEDULE
TRIA
D 1
2TH
AVE
NU
E41
19 &
412
3 12
TH A
VEN
UE
NE
SEAT
TLE,
WA
9810
5
TRIA
D C
APIT
AL