trelleborg engineered systems
TRANSCRIPT
ElectricalSafety Products
Trelleborg eNgINeereD SYSTeMS
1
Trelleborg eNgINeereD SYSTeMS
Trelleborg specifically compounds its elastomers and tests its products to ensure the highest standard of electrical protection.
Rubber safety products are simple and easy to use. They fold and hang easily and are durable with a long service life.
We are able to manufacture, test and certify products to the following standards:
• AmericanSocietyofTestingandMaterials(ASTM)inbothlow and high voltage
• AustralianandNewZealandstandards(AS/NZS)inlowvoltage
• BritishStandards(BS)inlowvoltage
• InternationalElectrotechnicalCommision(IEC)
AsanAS4801andOHSAS18001certifiedcompany,weareable to work with you to design and develop special safety products to meet your specific needs.
ElectricalA safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount.
Safety Products
2
Trelleborg eNgINeereD SYSTeMS
L.V. Cable Jointers Mat• ManufacturedandtestedtoAS/NZS2978-1995(650VAC
nominalsafeworking)orspecifiedstandard
• Taggedandcertified
• 1500x900x6.5mm
• DesignedtoprovideLVprotectionforpitjoiningoperations
• Storagebagsavailable
L.V. Safety Matting• ManufacturedandtestedtoAS/NZS2978-1995(650VAC
nominalsafeworking)orspecifiedstandard
• Tagged&certified
• ClassA-6.5mmthick,1000mmwideandupto10mlong,general purpose
• ClassB-3mmthick,1000mmwideandupto15mlong,suitable for smooth floor surfaces only
• Availableinblack,white*,blue*orred* (*Surchargeforcolour)
• Storagebagsavailable
L.V. Cabinet Drape• ManufacturedandtestedtoAS/NZS4202-1994(650vAC
nominalmaximumuseagevoltage)orspecifiedstandard
• Madetocustomersize(withinlimitationsofthespecifiedstandard)
• Taggedandcertified
• RobustUVresistantEPDM/Naturalrubber
• Suppliedwitheithermagneticbuttons,holesorvelcro
• Colours-Yellow/GreyorBlue
3
Trelleborg eNgINeereD SYSTeMS
Catenary Hardware & Cable Cover• Designedtocoverpoleconnectinghardwareandproximatecable
of potentially earthed pole sharing systems such as telephone or cable television
• Taggedandcertified
• Reducesriskofaccidentalcontactbylivelineworkersoperatingnearby
• ManufacturedtoconformtotheappropriateL.V.standard,depending upon customer requirements
• Holes,Velcroand/ormagneticfasteners
• Storagebagsavailable
Substation L.V. Mat Kit•SubstationLVMatKitforupto650V.Includesmagnetic
fasteners for quick attachment to any part of the panel.
•AS4202ClassIIContents:
•4of600x450x2mmduallayerinsulatingsheet
•2of1200x600x2mmduallayerinsulatingsheet
•1of1000x1000x3mmgroundmat
•1of1100x200x300mmRipstopzipperbag
4
Trelleborg eNgINeereD SYSTeMS
L.V. Crossarm Cover• ManufacturedandtestedtoAS/NZS4202-1994(650VAC
nominalsafeworking)orspecifiedstandard
• Taggedandcertified
• Standardsize1200x350drop.Madetoordersizesalsoavailable
• Reinforcedspine
• Availableinblack,yellow/greyorblue
• Holes,Velcroand/ormagneticfasteners
• Storagebagsavailable
5
Trelleborg eNgINeereD SYSTeMS
Cable Wrap• Usedextensivelyinpowergenerationfacilitiesandcontrolrooms
toprovidetemporarycoverontestpointswhenphasinginH.V.motors or controls
• Bluenaturalrubber/EPDMsupplied/GumRubberin2mmx100mmx1200mmrollswith500mmVelcrostrap
• Acceptancetestedtowithstand15kVinasinglethickness
Bus Bar and Switch Covers• Madetocustomerrequirements
• 300x300mmandlarger
• TestedtoeitherAS/NZS4202-1994(L.V.),orASTMD1048(H.V.)orotherspecifiedstandard
• Cabletie,peg,buttons,velcrofastenedormagneticbuttons
6
Trelleborg eNgINeereD SYSTeMS
L.V. Line Cover (Double Drop)• ManufacturedandtestedtoAS/NZS4202-1994(650VAC
nominalsafeworking)orspecifiedstandard
• Taggedandcertified
• Standardsizesare900,1000and1200mmlongwitheither300,350or400mmdrop
• 2mm(lightweight)or3mm(heavyduty)rubbersheetmoulded&reinforced to conform to the line profile
• Suppliedasabasiccoverorwithspongeinsertsforgreaterlinegrip(appliesonlyto3mmheavyduty)
• Holes,Velcroand/ormagneticfasteners
• Availableinblack,yellow/greyorblue
• Storagebagsavailable
L.V. Line Hose• ManufacturedandtestedtoAS/NZS4202-1994(650VAC
nominalsafeworking)orspecifiedstandard
• TaggedandCertified
• 25mm&32mmdiameterbore
• Manufacturedtomaximumlengthof2.5metres
• Availableinblack
• DesignedtobeeasilyplacedonLVoverheadwire
U.V. & Flame Resistante Cable Covers• ProoftestedtoAS/NZS4202-1994
• ManufacturedfromUV&Flameresistantpolymer
• Cuttorequiredlengthonthejob
• Availablein15mmID,10mmIDand10mrolls
• Grey
• Designedtocoverexposedcopperconductors&links
• Remainresilientandflexible
• Specificallydevelopedtoreducewildlifeinitiatedoutagesonsubstations and deadfall initiated bush fires
• Prooftestingcertificatesavailable
7
Trelleborg eNgINeereD SYSTeMS
Cable End Cover• Temporary,re-useableanddurablecableendcover
• Manufacturedfromdurablehighvisibilityblue2mmnaturalrubber
• Sizestosuitcustomersrequirements
• Acceptancetestedtowithstand5kV
Floor Cable Protector• ManufacturedinUVstable,abrasionresistantmaterials
• 10mlengths
• Availableinblack,white,yellowandorange
• Designedtoprotectandconcealinsulatedcablesinhighvolume and heavy traffic areas, including roadways
• Leadsareeasilyinsertedandwork-placesafetyisenhanced
Storage Bag• Manufacturedindurablewovenpolyethylenetosuitthe
following products:
- L.V.SafetyMatting
- H.V.SafetyMatting
- L.V.CableJointersMat
- L.V.LineCover
- L.V.CrossarmCover
- CatenaryHardware&CableCover
8
Trelleborg eNgINeereD SYSTeMS
TrelleborgBlanketsaremanufacturedtoASTM1048,Type2,Class4,StyleAandfeature a beaded edge with reinforced eyelets.
TrelleborgBlanketsareavailablein3sizes:
• 560 x 560 mm • 915 x 915 mm • 1220 x 1220mm
They are proudly manufactured inAustraliaforAustralianconditions and are available in orange.
ThespecialblendofEPDM/NaturalRubbergivessuperiorozoneresistance,tensilestrength,andflexibility.
AllTrelleborgBlanketsarefullycompliant and are supplied
either, tested and certified, or untested.
They have also been proof tested@40kVacinaccordancewithASTMD-1048-05:Section9.1.
Speciallydesignedcarrybagsare available to protect the blankets when not in use.
H.V. Electrical Insulating Blankets
H.V. Electrical
ASTM CLASS/PRooF TEST VoLT
TyPE / MATERIAL SIzE (MM) CoLoUR WEIgHT(Kg)
4/40kV EPDM/Natural 560x560 Orange 1.7
4/40kV EPDM/Natural 915x915 Orange 4.34
4/40kV EPDM/Natural 1220x1220 Orange 7.5
9
Trelleborg eNgINeereD SYSTeMS
Slotted Style H.V. Electrical Insulating Blankets
TrelleborgSlottedStyleBlanketsaremanufacturedtoASTM1048,Type2,Class4,StyleAand they feature a beaded edge with reinforced eyelets.
They are produced with a slot to add versatility to the product.
TheseBlanketsarenormallyused for protection over insulators,crossarmsand/orwires.
TrelleborgBlanketsareavailablein3sizes:
• 560 x 560 mm • 915 x 915 mm • 1220 x 1220 mm.
AllTrelleborgBlanketsarefullycompliant and are supplied tagged tested and certified.
They have also been tested @ 40kVacinaccordancewithASTMD-1048-05:Section9.1.
Speciallydesignedcarrybagsare available to protect the blankets when not in use.
ASTM class/Proof Test Volt
Type / Material Size (mm) Colour Weight(Kg)
4/40kV EPDM/Natural 560x560 Orange 1.7
4/40kV EPDM/Natural 915x915 Orange 4.34
4/40kV EPDM/Natural 1220x1220 Orange 7.5
H.V. Safety Matting• ManufacturedandtestedtoASTMD178-93
• Taggedandcertified
• Class2-6.5mmthick(17kVnominalsafeworking)
• Class3-9.5mmthick(26.5kVnominalsafeworking)
• Class4-12mmthick(36kVnominalsafeworking)
• Maximumof10metreslongand1000mmwide
• Storagebagsavailable
10
Trelleborg eNgINeereD SYSTeMS
H.V Diamond Pattern U.S. Milspec & IEC Matting• ManufacturedinaccordancewithMIL-DTL-15562G(Navy)31
May1996:ClassificationTypeIII
• Max.safeworking:30kV
• FireresistanttoMIL-STD-1623requirement
• Size:915mmx22metresx4.7mm(3ftx25ftx0.147inch).Cut to length available.
• Colour:Grey(Blueorgreenavailableasspecialorder)
• AlsomeetsIEC61111Class1requirmentsincluding20kVACwithstand test
H.V. Line Hose• ManufacturedandtestedtoASTMD1050-85class4(36kV
nominalsafeworking)
• TaggedandCertified
• Manufacturedtomaximumlengthof5metreswitha35mmbore
• Hosesuppliedinorangeorblack
• Speciallydevelopedcompoundallowsforlongterminstallationinhazardousenvironments
• Easilyplacedlockingsheath
Flame Resistant Substation Termination Cover•Manufacturedinflameresistant,selfextinguishingelastomer (IEC(V)flammabilitytestmethod)
•UVstable
•Reducesthepossibilityofwildlifeordeadfallinitiatedsupplyoutages or fires
•Easytofit‘knockon’lockingclips
•Australiandesignedandmanufactured
•Prooftestedto19kVflashover
•CompatiblewithTrelleborgUVresistantconductorandcablecover
www.trelleborg.com.AU
Trelleborg Engineered Systems Australia, Brisbane Head Office, 515 Zillmere Rd, Zillmere, Queensland, Australia 4034
Tel: +61 7 3866 7444 Fax: +61 7 3263 4912
Trelleborg is a world leader in engineered polymer solutions that seal, damp and protect critical applications in demanding environments. Our innovative engineered solutions accelerate performance for customers in a sustainable way. The Trelleborg Group has local presence in over 40 countries around the world.
facebook.com/Trelleborggroup
twitter.com/TrelleborgGroup
youtube.com/trelleborg
flickr.com/trelleborg
linkedin.com/company/trelleborg
Perth Office, 25 Glassford Rd, Kewdale, Western Australia, Australia 6105
Tel: +61 8 9256 6000 Fax: +61 8 9353 5990