tree protection fencing - elegant homes · 3. weldmesh wired to the uprights and horizontals 4....
TRANSCRIPT
NEIGHBOURINGGARAGE
Garage
EXTG BEECH HEDGEROW - 3M HIGHEXTG BEECH HEDGEROW - 3M HIGH
EXTG
M
ATUR
E B
EECH
HED
GERO
W -
3M
HIG
H
EXTG
M
ATUR
E B
EECH
HED
GERO
W -
3M
HIG
H
EXTG
BE
ECH
HE
DGER
OW
- 3
M H
IGH
EXTG
BE
ECH
HE
DGER
OW
- 3
M H
IGH
1.2m POST +RAIL FENCEwith STOCK PROOF WIRE
EXISTING BEECH TREE
WATER BUTT
1.2m POST +RAIL FENCE
Taxus Bacatta10 litre pots 1m High
planted at 500mm centres
Taxus Bacatta10 litre pots 1m High
planted at 500m centres
EXISTING PRIVET TREES
EXISTING PRIVET TREE
EXISTING PRIVET TREE
TRADITIONAL TIMBER SHED3 X 4.5M
WATER BUTT
EXISTINGLAWSON CYPRESS
TPFTPF
TPFTPF
TPFTPF
TP
F
TP
F
TP
F
TP
F
TP
F
TPF
L A W N
L A W N
P R O P O S E D S O A K A W A Y
P R O P O S E D S O A K A W A Y
Logs LogsLogs Logs
FAGUS SYLVATICAPlanted at 450mm centres
in two staggered rows
EXTG GATE RETAINED
Outline of ApprovedCurrently Under
Construction
Outline of ApprovedScheme Ref.
P14/S1953/FUL
Outline of ApprovedScheme Ref.P14/S1953/FUL
Garage
Garage
EXTG BEECH HEDGEROW - 3M HIGHEXTG BEECH HEDGEROW - 3M HIGH
EXTG
M
ATUR
E B
EECH
HED
GERO
W -
3M
HIG
H
EXTG
M
ATUR
E B
EECH
HED
GERO
W -
3M
HIG
H
EXTG
BE
ECH
HE
DGER
OW
- 3
M H
IGH
EXTG
BE
ECH
HE
DGER
OW
- 3
M H
IGH
EXTG
BE
ECH
HE
DGER
OW
- 3
M H
IGH
EXISTING BEECH TREE
TRADITIONAL TIMBER SHED3 X 4.5M
1.2m POST +RAIL FENCE
EXISTING PRIVET TREES
EXISTING PRIVET TREE
EXISTING PRIVET TREE
TRADITIONAL TIMBER SHED3 X 4.5M
EXISTINGLAWSON CYPRESS
TPFTPF
TPFTPF
TPFTPF
TP
F
TP
F
TP
F
TP
F
TP
F
TPF
12cm Girth 4m HighLIQUIDAMBAR STYRACIFLUA
L A W N
L A W N
Logs LogsLogs Logs
FAGUS SYLVATICAPlanted at 450mm centres
in two staggered rows
Oak Edgings
Oak Edgings
Oak Edgings
Oak Edgings
RIDGE LEVEL: 47.10
SLAB LEVEL: 38.9
EXTG
BE
ECH
HE
DGER
OW
8m
4m
0m 2m
1m
1:200 scale BarThis Drawing has been produced for printing onto A1 size paper,If printing on A3 please use the scale below for reference.
Tree Protection Fencing
- Provide tubular scaffold framed fencing where shown, being 1.2m in height and faced with weldmesh. All in accordance with BS 5837: 2012.
NOTES
1. All tree works are to be completed by approved contractor working tostandards set out in BS 3998 before any other works take place on site.
2. After completion of the tree works and before any plant, equipment ormaterials enter the site the protective fencing as shown shall be erected.No activity, storage of materials, liquids of any sort or source are permittedwithin the protective fencing at any time.
3. The site agent is to inspect the protective fencing daily and make good anydefects imediately on discovery.
4. Car parking and or paving within the protective fencing near trees shall be of a'no dig' installation and be installed after the main construction programme iscompleted. To install the hard surfaces the protective fence can be taken downby hand and moved off site. The installation can then proceed using only miniexcavators of 2 tonne maximum capacity operating from outside the formerprotected area or from the newly laid sub base.
5. Edgings to hard surfaces within the former protected areas of the trees are tobe supported by driven pegs only. Continuous trenched haunching isprohibited.
6. Ground level changes are only to be made outside the protective fencing andmay require a retaining wall structure if conventional banking cannot fit.
7. The protective fencing may only be removed after the main construction worksare complete. The fencing is to be taken down by hand equipment only andtaken off site.
8. Soft landscaping within the former protected areas is to be completed by handor with hand operated equipment only. Cultivation of soils is to be keptwithin the top 100mm of the existing soil profile within former protected areasexcept for the planting of larger plants and trees.
6
4
1
7
6
5
3
2
2.3m
3.0m
1. Standard scaffold poles
2. Uprights to be driven into the ground
3. Weldmesh wired to the uprights and horizontals
4. Standard clamps
5. Wire twisted and secured on inside face of fencing toavoid easy dismantling
6. Ground level
7. Approximately 0.6m driven into the ground
Figure 2 - Protective Barrier
L E G E N D
Tree ProtectiveFencing/Barrier(Refer to Figure2 for Details)
TPF
TP
F
Proposed Hedge
Existing Tree/Hedgeto be retained
Proposed Tree
backfilled trench with50cm deep, plastic routebarrier membranelocation shown. Toinclude Platypus RootAnchor straps orsimilar.
Ms H Simpkin & Mr I Simpkin
Morriston, Fairmile, Henley on ThamesHenley on Thames, RG9 2JXPROPOSED SITE PLAN
1:200 @ A1 ES Nov 2018 3144 / 206 F
Day Tanner Ltd ARCHITECTUREAND PLANNING
©
A General Alterations PB Apr 2017B General Revisions GH May 2017C General Additions PB May 2017D General Alterations PB June 2017E General Alterations ES Nov 2018F General Alterations DN 08.04. 2019
1:100 scale Bar
This Drawing has been produced for printing onto A3 size paper,
1m
2m 8m
0m
0.5m
4m
Velux 350mm dia suntunnel
Obscure
glazed
Obscure
glazed
East Elevation
North Elevation
DATEDRAWNSCALE
DRG
JOB
CLIENT
Day Tanner Partnershipwww.daytanner.co.uk
ARCHITECTURE
A N D P L A N N I N G
Rev Description DateBy
Disclaimer
THIS DRAWING MUST NOT BE SCALED UNLESS ISSUED FOR PLANNING
PURPOSES.
ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO SETTING OUT,
COMMENCING WORK, OR PRODUCTION OF FABRICATION DRAWINGS.
REPORT ANY DISCREPANCIES TO THE SUPERVISING OFFICER IMMEDIATELY.
DRAWINGS MARKED AS 'DRAFT' ARE FOR APPROVAL ONLY AND NOT
ISSUED FOR CONSTRUCTION PURPOSES. COPYRIGHT ©
Suite 1A
Market House
19-21 Market Place
Wokingham
Berkshire
RG40 1AP
0118 989 0808
Ms H Simpkin & Mr I Simpkin
Morriston, Fairmile, Henley on ThamesHenley on Thames, RG9 2JX
PROPOSED ELEVATIONS 1 of 2
1:100 @ A3 ES Nov 2018 3144 / 203 C
A General Revisions GH May 2017
B Gable Window Revised PB May 2017
C General Revisions ES Nov 2018
1:100 scale Bar
This Drawing has been produced for printing onto A3 size paper,
1m
2m 8m
0m
0.5m
4m
Velux 350mm dia suntunnel
Velux 350mm dia suntunnel
Velux 350mm dia suntunnel
Velux 350mm dia suntunnel
Velux 350mm dia suntunnel
West Elevation
South Elevation
DATEDRAWNSCALE
DRG
JOB
CLIENT
Day Tanner Partnershipwww.daytanner.co.uk
ARCHITECTURE
A N D P L A N N I N G
Rev Description DateBy
Disclaimer
THIS DRAWING MUST NOT BE SCALED UNLESS ISSUED FOR PLANNING
PURPOSES.
ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO SETTING OUT,
COMMENCING WORK, OR PRODUCTION OF FABRICATION DRAWINGS.
REPORT ANY DISCREPANCIES TO THE SUPERVISING OFFICER IMMEDIATELY.
DRAWINGS MARKED AS 'DRAFT' ARE FOR APPROVAL ONLY AND NOT
ISSUED FOR CONSTRUCTION PURPOSES. COPYRIGHT ©
Suite 1A
Market House
19-21 Market Place
Wokingham
Berkshire
RG40 1AP
0118 989 0808
Ms H Simpkin & Mr I Simpkin
Morriston, Fairmile, Henley on ThamesHenley on Thames, RG9 2JX
PROPOSED ELEVATIONS 2 of 2
1:100 @ A3 ES Nov 2018 3144 / 204 B
A General Revisions GH May 2017
B General Revisions ES Nov 2017
1:100 scale Bar
This Drawing has been produced for printing onto A3 size paper,
1m
2m 8m
0m
0.5m
4m
Dining
Kitchen
Study
Living
Utility
Family
C
wc
Dining
Kitchen
Study
Living
Utility
Family
C
wc
Hall
Garage
Hall
Ground Floor PlansMs H Simpkin & Mr. I Simpkin
Morriston, Fairmile, Henley on Thames
RG9 2JX
PROPOSED GROUND FLOOR PLANS
1:100@A3 ES Nov 2018 3144/201 BDATEDRAWNSCALE
DRG
JOB
CLIENT
Day Tanner Partnershipwww.daytanner.co.uk
ARCHITECTURE
A N D P L A N N I N G
Rev Description DateBy
Disclaimer
THIS DRAWING MUST NOT BE SCALED UNLESS ISSUED FOR PLANNING
PURPOSES.
ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO SETTING OUT,
COMMENCING WORK, OR PRODUCTION OF FABRICATION DRAWINGS.
REPORT ANY DISCREPANCIES TO THE SUPERVISING OFFICER IMMEDIATELY.
DRAWINGS MARKED AS 'DRAFT' ARE FOR APPROVAL ONLY AND NOT
ISSUED FOR CONSTRUCTION PURPOSES. COPYRIGHT ©
Suite 1A
Market House
19-21 Market Place
Wokingham
Berkshire
RG40 1AP
0118 989 0808
A General Revisions GH May 2017
B General Revisions ES Nov 2018
1:100 scale Bar
This Drawing has been produced for printing onto A3 size paper,
1m
2m 8m
0m
0.5m
4m
Bed 4
Bed 3
Bed 2
Bed 1
Ens 1
Ens 2
Dress
Bath
ac
Bed 4
Bed 3
Bed 2
Bed 1
Ens 1
Ens 2
Dress
Bath
acGarage roof
LandingLanding Sun tunnel over Sun tunnel over
Sun tunnel over
Sun tunnel overSun tunnel over
Sun tunnel over
First Floor Plan
DATEDRAWNSCALE
DRG
JOB
CLIENT
Day Tanner Partnershipwww.daytanner.co.uk
ARCHITECTURE
A N D P L A N N I N G
Rev Description DateBy
Disclaimer
THIS DRAWING MUST NOT BE SCALED UNLESS ISSUED FOR PLANNING
PURPOSES.
ALL DIMENSIONS ARE TO BE VERIFIED PRIOR TO SETTING OUT,
COMMENCING WORK, OR PRODUCTION OF FABRICATION DRAWINGS.
REPORT ANY DISCREPANCIES TO THE SUPERVISING OFFICER IMMEDIATELY.
DRAWINGS MARKED AS 'DRAFT' ARE FOR APPROVAL ONLY AND NOT
ISSUED FOR CONSTRUCTION PURPOSES. COPYRIGHT ©
Suite 1A
Market House
19-21 Market Place
Wokingham
Berkshire
RG40 1AP
0118 989 0808
Ms H Simpkin & Mr I Simpkin
Morriston, Fairmile, Henley on ThamesHenley on Thames, RG9 2JX
PROPOSED FIRST FLOOR PLANS
1:100 @ A3 ES Nov 2018 3144 / 202 C
A General Revisions GH May 2017
B Gable Window Revised PB May 2017
C General Revisions ES Nov 2018