    Marine Survey Report

    SAMPLE

    1987 Ta Chiao CT 35

    Prepared Exclusively

    for

    SAMPLE

     

    Report Date: April 20, 2016

  • 8/17/2019 Trawler Sample Report

    2/33

    Sun Coast Marine Surveying & Consulting LLC

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 1 of 32

    SURVEY REPORT TABLE OF CONTENTS

    Major Systems Surveyed Page No.

    GENERAL INFORMATION 2

    EXTERIOR HULL, DECK & BOTTOM INSPECTION 4

    HELM STATIONS & NAVIGATION ELECTRONICS 11

    CABIN INTERIOR APPOINTMENTS 13

    ELECTRICAL SYSTEMS 15

    INBOARD PROPULSION SYSTEM 17

    STEERING SYSTEM 19

    TANKAGE 20

    SAFETY EQUIPMENT 23

    SEA TRIAL 25

  • 8/17/2019 Trawler Sample Report

    3/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 2 of 32

    GENERAL INFORMATION

    OPENING REMARKS & VESSEL SPECIFICS

    This Is To Certify that the undersigned Marine Surveyor acting on behalf of Sun

    Coast Marine Surveying & Consulting, LLC inspected the referenced the single

    diesel powered fiberglass motor vessel on the dates specified.

    Purpose of Survey The survey was made at the request of the named client and for his/her account, in

    order to ascertain the vessel's general condition and valuation for (pre-purchase)consideration.

    Attending Surveyor: Attending Surveyor Representing Buyers Interest: J. Chet Stephens SA.

    Circumstances of Survey: The vessel was inspected while afloat in its berth and later hauled for an inspection

    of the waterline hull, appendages and machinery. All accessible compartments

    were entered, but do to paneling, liner, tanks, and installed equipment only about

    20 percent of the hulls interior surface could be observed. The specific materials

    and lay up schedule for the fiberglass moldings could not be determined with the

    non-destructive techniques available for inspection. A formal sea trial was

    performed. Machinery and equipment were inspected while operating unless

    specifically noted. Electrical power was available and used during the inspection.

    The deck and superstructure were examined visually and by way of ransom

    percussion testing, random moisture meter readings, and thermal imaging. Thebelow draw waterline hull and appendages were examined visually and by of 

    random percussion testing and thermal imaging were applicable. Moisture meter

    readings were not taken because of the presence of metallic based antifouling paint

    and limited drying time.

    NOTE: Ownership, HIN and Official numbers from documents. Numbers verified

    on hull. All specifications included in report are from official documents or sources

    such as USCG Documentation, state registration, manufacturer's data or other

    reference materials and were not measured during the inspection.

    Surveyor Qualifications: The surveyor is a member of SAMS (Society of 

    Accredited Marine Surveyors), and a Certified

    Standards Technician with ABYC (AmericanBoat and Yacht Council)

    Intended use: Recreational.

    CLIENT

    Client name:

     

    Street address:

     

    City/State/Zip:

     .

    SURVEY LOCATION

    In Water Portion:  

    Out of Water Portion: Murrelle Marine 846 N Dixie Hwy, Lantana, FL.

    VESSEL INFORMATION

    Vessel Yr/Make/Model: 1987 CT Trawler T35.

    Vessel name:  .

    Hailing port:  .

  • 8/17/2019 Trawler Sample Report

    4/33

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 3 of 32

    Hull ID number (HIN):

    XXXXXXXXX - A true digital photograph of the hull ID number of the

    referenced vessel is shown here.

    Manufacturer/Builder: Ta Chiao Bros Yacht Building Company Taipei Tiawan.

    VESSEL SPECIFICATIONS

    Length overall (L.O.A.): 34'11" per manufacturer spec's.

    Load length water line

    (L.W.L.)

    30'5" per manufacturer spec's.

    Beam: 12'0" per manufacturer spec's.

    Draft: 3'4.5" per manufacturer spec's.

    Displacement: 19800 lbs per manufacturer spec's.

    Fuel Capacity: 300 U.S. Gallons (US Gals) total.

    Fresh Water Capacity: 200 U.S. Gallons.

    BLK Water Tank

    Capacity:

      40 U.S. Gallons.

    Hot Water Tank Capacity:   11 U.S. Gallons.

    U.S.C.G. OFFICIAL DOCUMENTATION

    Official Documentation

    No:

    000000 permanently affixed per USCG regulations. A true digital photograph of 

    the Official Documentation number of the referenced vessel is shown here:

    Documented gross tons: 15 GRT.

    Documented net tons: 12 NRT.

    Documented owner: Ira Oaklander.

    Documentation current: Yes Expires: 12/31/2016.

  • 8/17/2019 Trawler Sample Report

    5/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 4 of 32

    EXTERIOR HULL, DECK & BOTTOM INSPECTION

    DESIGN CHARATERISTICS

    Standard

    Standard Manufactures Model

    HULL: Displacement type hull with moderately raked bow, vertical withincreasing flare forward, straight reverse sheer and square stern with drive

    platform. The bottom is a deep V design, steered with a single rudder.

    DECK(S) & SUPERSTRUCTURE: Single level deck with raised foredeck and

    dual level recessed cabin house superstructure with fly bridge and bimini top.

    WATERTIGHT INTEGRITY: A single water tight compartment divided into

    separate cabins by apparently non-watertight bulkheads and a overboard self 

    draining anchor locker at the fore peak. The hatches and portholes opening to the

    exterior hull, weather decks, and cockpit were apparently water tight types (ABYC

    Standards H-3) except for the companionway, cockpit locker hatches, and coach

    roof windows which were apparently water tight. The companionway wasequipped with a sill instead of a bridge deck and the cockpit was a self draining

    type via scuppers located at the aft outboard corners of the aft deck.

    HULL, DECK & SUPERSTRUCTURE

    Hull Deck &

    Superstructure:

    Conventional fiberglass reinforced plastic (FRP) moldings with unknown core

    material, white gel coat exterior shell below the waterline and white gel coat above

    the waterline with bulkheads grafted to the hull with FRP laminates. Deck has

    unknown core with white exterior gel coat surfaces and molded in anti-skid texture

    in tread areas on the flybridge and teak deck surfaces on the main deck. Hull-deck 

     joint is a shoe box design sealed with an elastomeric type compound and FRP

    tabbing where observed. Joint protection provided by an external varnished teak 

    rub rail with a second rail of molded FRP with stainless steel striker molding andstainless steel fasteners just above the waterline. (See Findings &

    Recommendations Priority II)

    Structural Members: Transverse longitudinal and athwartship framing system comprised of FRP

    encapsulated longitudinal box stringers and frames of an unknown core material.

    Stringers measuring approximately 3.5 inches in width and 10 inches in height.

    Both stringers and frames laminated to the hulls interior along with full and partial

    teak bulkheads and plywood floors grafted to the hull with FRP laminates and full

    and partial plywood bulkheads secured with mechanical fasteners.

  • 8/17/2019 Trawler Sample Report

    6/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 5 of 32

    Interior Construction: Teak bulkheads and doors, FRP head and hull liner sections, pre molded FRP liner

    sections. Formica type counter tops, teak and holly cabin sole.

    Bottom Paint: (See Findings & Recommendations Priority II)

    Blister Comments:  Blisters are an unknown factor on all boats and if not currently present, there is no

    guarantee that they will not appear in the future. Blisters have a tendency to dry

    out over winter storage unless severe or large. Blisters (if any) best appear after 

    vessel has been in water for an entire season. In addition, the symptomatic

    evidence of blistering can be obscured by bottom coatings, a dry storage period 

    during which blisters spontaneously depressurize, bottom laminate sanding, and other conditions or actions. Recommend full inspection for blisters immediately

    after haul-out and power wash. Surveyor has no firsthand knowledge of the history

    of bottom maintenance, blistering, repairs or prophylactic coatings on this vessel.

    Transom: Conventional transom, Well secured, no cracks or defects sighted. Moisture

    readings were relatively Dry. No delamination when checked with a percussion

    hammer.

    Photograph(s):

     

  • 8/17/2019 Trawler Sample Report

    7/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 6 of 32

     

    Recommendations:

  • 8/17/2019 Trawler Sample Report

    8/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 7 of 32

    ABOVE WATERLINE HULL, DECK, SUPERSTRUCTURE, HARDWARE & FITTINGS

    Deck Floorplan:

    Standard manufactures deck layout with no modifications to the original design.

    Anchor Platform: Attached teak platform with dual stainless steel roller assembly. Platform is secure

    and shows normal wear and tear.

    Toe Rails, Rails,

    Stanchions & Life Lines:

    Molded FRP toe rail, part of deck lay up with varnished teak cap rail, polished

    stainless steel bow rail mounted to the deck with stainless steel fasteners and

    stainless steel stanchions with varnished teak rail. Gates located on both port and

    starboard sides with one on the transom. Polished stainless steel safety rail system

    at flybridge secured with stainless steel fasteners. Firmly mounted and serviceable

    except as otherwise noted. (See Findings & Recommendations Priority I) (See

    Findings & Recommendations Priority II) 

    Mooring Hardware: Stainless steel horn cleats and fairleads. All were secure and showed minimal wear

    and tear .

    Hatches, Portholes,

    Portlight, Doors &

    Windows:

    Glass cabin trunk windows and sliding companionway door and aluminum framed

    hatch with Lexan type window at the forward and side end of the cabin house.

    Hatch sufficiently sized to act as a fire escape per NFPA 302. Stainless steel

    framed portholes with Lexan type windows at the ADWL hull and cord FRPhatches. Intact and serviceable except as otherwise noted.

    Exterior Seating & Tables: The exterior seat structures were firmly mounted and the upholstery was

    serviceable showing minimal wear and tear for age.

    Cockpit Equipment: Fenders

    Dock Lines

    Canvas cockpit cover

    Cabin house window mesh covering

    Rail grill.

    Boarding Ladder: Stainless steel drop down mounted on the teak swim platform and well secured

    showing moderate wear and tear.

    Swim Platform: Teak mounted platform well secured. (See Findings & RecommendationsPriority II)

    Above Draw Water Line

    (DWL) Thru Hulls:

    Marelon thru hull fittings sighted. (See Findings & Recommendations Other

    Observations)

  • 8/17/2019 Trawler Sample Report

    9/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 8 of 32

    Photograph(s):

     

  • 8/17/2019 Trawler Sample Report

    10/33

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 9 of 32

    BELOW DRAW WATERLINE SKIN FITTINGS, MACHINERY & HARDWARE

    Below DWL Thru Hull

    Fittings:

    Bronze fittings appear to be in serviceable condition with limited wastage.

    Transducer(s): Bronze type. Intact. (See Findings & Recommendations Priority II)

    Faring Block(s): Wood fairing block for depth and seed transducer.

    Sea Valves / Sea Cock

    Type:

    Bronze sea cocks with mounting flanges.

    Sea Strainers: Bronze Internal strainer(s) installed. Strainers were inspected visually for cracks orany evidence of blockage. Strainers were not opened and inspected due to

    destructive testing restrictions. It is recommend the buyer open and inspect each

    strainer prior to taking delivery.

    Bow/Stern Thruster: Vetus bow and stern thruster each with six bladed props. All blades intact.

    Note: This company suggests the sea cock/ sea valves be serviced according to the

    manufactures recommendations as a preventative measure upon purchasing a used 

    vessel and thereafter as recommended by the sea cock/ sea valve manufacturer or 

    more frequently as a part of the vessel's regular maintenance program. We also

    strongly recommend that one of vessel was left unattended that all below waterline

    sea valves be closed with the exception of scuppers, bilge pump discharge, or other 

    valves that are required to be in the open position to prevent flooding of the vessel

    during inclement weather. This provides an extra measure of safety for the vesselas well as the added benefit of familiarizing the crew with safety valve locations

    and to exercise the valves to prevent seizure.

     Moreover, if not already done so, it is strongly suggested that properly sized 

    tapered wooden plugs be kept in the vicinity of each sea cock/sea valve/thru hull to

    be used as a plugging device in the case of an emergency. Finally, when renewing

    the vessels protective coatings, it must be kept in mind that antifouling paints

    containing copper or other metals must not be applied to metal fittings and/or 

    machinery without first having an insulated coating such as underwater metal

     primer or epoxy barrier coat applied. Failure to do so can result in harmful

    galvanic corrosion damage to the fittings and/or machinery.

    Condition & Comments: In apparent serviceable condition except as noted in the Findings &Recommendations. 

    Photograph(s):

     

  • 8/17/2019 Trawler Sample Report

    11/33

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 10 of 32

     

    CATHODIC PROTECTION

    Bonding System: The bonding system was found to be using an individual green insulated bonding

    wire and shaft bushings at the prop shafts. Appeared to be serviceable were sighted

    except as indicated otherwise in this report. (See Findings & Recommendations

    Priority II) 

    Lighting Protection: None, but not normally found on boats of this type.

     Note: Few boats are actually wired for lightning protection from the manufacture.

    There is no known way to ensure complete protection for personnel and equipment 

     from a lightning strike. However, we suggest that any owner review the

    information at www.marinelightining.com and ABYC TE_4.

    Additional Remarks:  A separate bonding system survey was not performed, and a corrosion meter was

     not used to establish the level of protection. If a more detailed analysis is

     required, a complete separate bonding system survey is recommended.

  • 8/17/2019 Trawler Sample Report

    12/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 11 of 32

    Note:  A vessels bonding system should be checked as part of the vessel's regular

     maintenance program. Each bonding wire should be checked regularly for

     corrosion, and its connection should be checked for connectivity. Resistance

     should be less than one (1) Ohm.

    Photograph(s):

     

    HELM STATIONS & NAVIGATION ELECTRONICS

    NAVIGATION ELECTRONICS

    Helm Station: Electronics mounted on cockpit bulkhead on the bridge and pilothouse. Bridge

    Helm: A 4" Richie powerdamnp compass in serviceable condition. The accuracy

     of the compass was not verified. A B&G VHF radio, powered up and received

    transmission. Garmin GPS Map 545 S chart plotter with navigational charts.

    Pilothouse: 6" Dansforth Constellation compass in serviceable condition. The

     accuracy of the compass was not verified. ICOM IC-M59 VHF Radio that

    powered up and functioned when testing using the Sea Tow automated system.

    Furuno LS600 depth sounder and Furuno 821 Charltplotter. A Furuno 821 Radar

    unit. A Furuno Radar FMD 811 unit was sighted inside a cabinet, not tested. All

    navigational units powered up and functionedunless noted in Findings &

    Recommendations. Units showed limited wear and tear. (See Findings &

    Recommendations Priority I) 

  • 8/17/2019 Trawler Sample Report

    13/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 12 of 32

    Photograph(s):

     

    ENGINE INSTRUMENTS AND CONTROLS

    Throttle and Shift

    Controls:

    Morse, Separate levers for each engine throttle and shift control. control works

    smoothly.

    OTHER ELECTRONICS AND CONTROLS

    Thrusters: Vetus thruster controls at both helms. Controls are in serviceable condition and

    show limited wear and tear.

  • 8/17/2019 Trawler Sample Report

    14/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 13 of 32

    Windshield Wiper(s): Port and starboard wipers at the pilothouse cabin windshield . (See Findings &

    Recommendations Priority II)

    CABIN INTERIOR APPOINTMENTS

    ACCOMMODATIONS

    Interior Layout:

    Standard manufacture layout, no interior changes to the original factory

     designed interior. Not to scale. For general information purposes only.

    Entertainment/Berthing &

    Salon:

    Sony brand in dash type (automotive style) 12 VDc model CDX-M50IP

    CD/MP3/AM/FM digital stereo mounted in the cabin above the pilothouse. Aforward V berth that sleeps two. An aft berth that serves as the master stateroom.

    The stereo powered up and appeared to function normally and showed negligible

    wear and tear. The salon is midship and serves as a dinette on the starboard side of 

    the cabin. The salon shows negligible wear and tear and is in good condition.

    Interior Lighting: 12 VDc . Operable except as noted in the findings.

    Galley/ Dinette &

    Accessories:

    The galley was fitted with a Corian like counter top, storage lockers, cabinets and

    drawers. A single stainless steel sink and piped with flex type drain hose secured

    with hose clamp and polished stainless steel faucet. Fixed mounted Force 10

    Marine two burner propane stove with oven, cabinet mounted Waeco 120

    VAc/12VDc upright refrigerator/freezer with door lock. All of the galley

    appliances and equipment operated normally unless noted in Findings &Recommendations and presented low exterior wear and tear. The galley

    arrangement was also considered adequate for the vessel type. (See Findings &

    Recommendations Other Observations) 

    Water Closet(s): Two water closets formed with pre-molded FRP liner module with gelcoat & teak 

    exterior surfaces and Corian type counter. Wash basins piped with flex hose and

    secured with hose clamps to polished stainless steel faucets. Integrated shower

    stalls with drain on sole. 12VDc exhaust fan. Jabsco brand marine heads (Toilet)

    that are manual pump flush systems piped with reinforced hoses and secured with

    hose clamps. The installed equipment operated normally and presented lmoderate

    wear and tear.

    Climate Control: The vessel was equipped with two 120 VAc MarineAir brand units. A forward unit

    located below the hanging closet is a 7000BTU unit, midship below in the engine

    room is the salon and aft berth unit that is 16000 BTU unit. All controls are digital

    controls. Both units powered up and operated in both heat and cold functions.

  • 8/17/2019 Trawler Sample Report

    15/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 14 of 32

    Photograph(s):

     

  • 8/17/2019 Trawler Sample Report

    16/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 15 of 32

     

    ELECTRICAL SYSTEMS

    DIRECT CURRENT (D.C). SYSTEMS

    Direct Current System(s)

    Type:

    The vessel was equipped with a single 12VDc system consisting of two battery

    banks. (4) 6VDc wet cell lead acid batteries wired in series to create 12VDc are

    located in the engine compartment that serve as the vessel house battery bank and

    are in plastic battery boxes with lids. There is (1) Group 31 battery that services as

    the engine start battery, windless and thrusters also enclosed ina battery box with

    lid. One Guest rotary switch is located in the engine compartment. Where visible

    the vessel was wired with multi stranded copper conductors with plastic type

    insulation. Much of the wire did not appear to have been modified from its factoryinstallation. (but some unused wiring and poorly supported wiring was observed in

    various areas.) Furthermore, were observed, no indications of overheating

    conductor insulation was observed. The terminals were splices could be seen,

    consisted of ring terminals, terminal plugs, spade and blade terminals, fork 

    terminals, common butt splices, and waterproof butt splices unless otherwise noted

    in Findings & Recommendations. Battery charging was accomplished by 12 VDc

    unknown amperage alternator on the engine, and shore power by the Freedom

    Marine 20 inverter/ battery charger that powered up. The main DC panel board is

    located on the starboard side wall of the main salon next to the pilothouse. All

    panels were clearly marked for voltage. Over current protection of the system was

    provided by a variety of in-line fuses of different types, push button thermal reset

    breakers and circuit breakers. (See Findings & Recommendations Priority II)

  • 8/17/2019 Trawler Sample Report

    17/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 16 of 32

    Photograph(s):

     

    ALTERNATING CURRENT (A.C.) SYSTEM(S)

    Shore Power System: The vessel was equipped with one 120 VAc Hubbel 30 amp and one 120 VAc

    Marinco 30 amp dual phase Ac system. The vessel shore power connections were

    located on the starboard side of the cabin house that are hardwired to the system.

    The operable main shore power circuit breaker is located at the AC distribution

    panel in the main salon. All breakers were operable and analog volt and amp

    gauges were installed at the power panel. Over current protection was provided for

    with individual branch circuit breakers in addition to the main shore power circuit

    breaker installed at the panel board. Where accessible and visible, the shore powers

    system's consisted of multi stranded copper conductors with plastic type insulation,

    and the terminal's consisted of ringing terminals and butt slices. The system's

    wiring in so far as could be determined did not appear to be modified from its

    factory installation, and no indications of overheating of the visible portion's of the

    wiring insulation was found. The Ac panel board was fitted with reverse polarity

    indicators which were functioning. GFCI protected AC receptacles were installedin the vessel. The systems impedance, voltage drop, polarity and GFCI function

    were tested at each Ac receptacle with a Suretester device with shore power and

    generator supplied power and tested normal. As far as could be determined by

    general examination without making disassemblies, system was found to be in

    apparent good working order.

  • 8/17/2019 Trawler Sample Report

    18/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 17 of 32

    Photograph(s):

     

    INBOARD PROPULSION SYSTEM

    MACHINERYEngine(s) & Bearer(s): One Volvo model TMD-41A in-line six cylinder diesel engines with raw watercooled closed loop cooling system and wet type of exhaust with 150 rated horse

    power. The engine was secured to the vessels longitudinal main stringers made fast

    by stainless steel engine mount fasteners. Drip pads were available to prevent fluid

    and the debris falling into the bilge area beneath the engines. The engines cooling

    systems was equipped with an engine mounted heat exchanger, engine mounted

    raw water cooling pumps, engine mounted closed system circulating pumps,

    remotely mounted closed system expansion bottle and pipe with reinforced hard

    wall marine water hoses secured with hose clamps, engine mounted 0EM type

    cooling system hoses secured with hose clamps and metal piping. Bronze raw water

    strainer with site glass were incorporated into the raw water intake hoses, and the

    raw water was discharged to the exhaust at the mixing elbows. The exhaust systemswere wet type with approved high-temperature silicon wet exhaust hose sections,

    common approved type wet exhaust hoses, metal exhaust tubing and discharged to

    the aft stern quarters through a stainless steel exhaust port. All sighted exhaust hose

    connections were made fast with double hose clamps per ABYC recommendations.

    All hoses appear to be in serviceable condition unless otherwise indicated in

    Finding & Recommendations. Belt condition appears to be serviceable with no

    cracks or evidence of built dust sighted. All fluid levels appeared to be full. (See

    Findings & Recommendations Priority I)

  • 8/17/2019 Trawler Sample Report

    19/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 18 of 32

    Serial No(s): Not sighted.

    Engine(s)Hours: 1851 hrs on meter.

    Controls & Alarms: All controls and alarms functioned when tested.

    Other Note: 

    It is good practice when buying a used vessel that all fluids

    (Engine/Transmission or Outdrive ) be changed and the raw water cooling

    impeller(s) also be changed.

    As stated in the Terms and Conditions agreement, It is understood that the

    attending surveyor is not an engine/transmission surveyor. As such, I

    recommend that all engines and transmissions be inspected by a qualifiedexpert engine surveyor/mechanic to determine the internal condition and any

    repairs necessary of the engine(s), transmission gears, and pumps, heat

    exchangers, coolers, etc.

    Reverse Gear(s): No tags were visible on transmission. Unknown manufacture or gearing ratio.

    Shafting & Propeller: The shaft is stainless steel with a 1-1/2" diameter. Shaft shows minimal wear and

    tear. The prop is a a 3 bladed bronze prop showing minimal wear and tear.

    Photographs:

     

  • 8/17/2019 Trawler Sample Report

    20/33

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 19 of 32

     

    STEERING SYSTEM

    STEERING SYSTEM

    Manufacturer & Type: Wagner, Hydraulic lines and ram cylinder with attached rudder tiller on rudder

    stock.

    Steering System

    Components

    Helm pump wheel assembly, reinforced steering system hoses, hydraulic ram,

    painted steel drag link with clevis ends, auto pilot reference sensor, bronze tiller

    arms with set screws secured with safety wire, bronze upper rubber and bear cross

    members secured to the longitudinal stringers with stainless steal fasteners, bronze

    rudder ports/packing glands secured to the hull using stainless steel fasteners, and

    bronze rudder with stainless steel stocks secured by the tiller arms and fitted with

    stainless steel cotter pins at the top to act as safety' s. Where visible the

    components were adequately mounted and no indication of fluid leaks were noted.The system operated normally, and no evidence of damage was found on the

    rudder. Furthermore, none were found at the packing glands.

     Note: Upon purchase of a used vessel this company suggests, the steering system

     be serviced according to the manufacturer's recommendations as a preventive

     measure and inspected regularly thereafter as part of a regular on-going

     maintenance program.

  • 8/17/2019 Trawler Sample Report

    21/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 20 of 32

    Photograph(s):

     

    TANKAGE

    FUEL TANK(S) & PIPING

    No & Location: Four tanks located, In engine space, on the port and starboard sides with no visible

    manufactures labels. The tanks were secured with stainless steel fasteners to the

    stringers and hull. Grounding conductors were observed at the tanks and both pipe

    to weather deck mounted stainless steel pipes market for diesel. The fill hoses were

    USCG approved Type A hoses secured with double hose clamps where visible

    unless otherwise noted in the Findings & Recommendations Section.. The tanks

    were vented to topside mounted fittings with flames screens and were plumbed

    with SAE j1527 hoses secured with hose clamps. The fuel supply and return hoses

    were also SAEj1527 with swaged mechanical fittings, and the engines were

    equipped with OEM type flexible fuel lines and metal fuel tubing. Fuel filtration

    was provided by two remotely mounted Raycor primary fuel filters and enginemounted OEM type fuel filters. Fuel shutoff valves were cited and accessed at the

    aft salon sole. Tanks are not the original tanks and were replaced within the last 10

    years. (See Findings & Recommendations Priority I) 

  • 8/17/2019 Trawler Sample Report

    22/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 21 of 32

    Photograph(s):

     

    FRESH WATER TANK(S)

    No & Locations of 

    Tank(s):

    Two water tanks are mounted in the aft deck steering house compartment. Tanks

    are made of stainless steel and secured by wood framing attached to the vessel hull.

    The freshwater system is equipped with a Jabsco brand 12VDc on demand water

    pump located in the engine compartment, water pump was functional when tested.

    (See Findings & Recommendations Priority II)

  • 8/17/2019 Trawler Sample Report

    23/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 22 of 32

    Photograph(s):

     

    HOLDING TANK(S) - BLACK WATER

    Marine Sanitation Device: Certification Type: MSD U.S.C.G. Type III. (Holding tank). Waste tank is

    connected to deck waste fitting for pump out. (See Findings &

    Recommendations Priority II)

    Photograph(s):

     

    WATER HEATER

    Tank Tyoe & Location: Stainless steel Seaward 11 gallon hot water tank mounted in the engine room. Tank 

    is well secured, ignition protected and has a pressure relief valve. Tank provided

    hot water when tested. Tank shows minimal wear and tear.

  • 8/17/2019 Trawler Sample Report

    24/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 23 of 32

    Photograph(s):

     

    LPG (PROPANE) TANK(S)

    No & Location of Tanks: A Propane locker is mounted on the bow aft of the anchor platform. The locker if 

    designed for two tanks, only one tank was in the locker on the day of the survey.

    Tank is properly fitted with the Overflow Protection Device (OPD), regulator at the

    tank with valve and solenoid is located in the galley.

    Photographs:

     

    SAFETY EQUIPMENT

    U.S.C.G. REQUIREDNavigation Lights: All Navigation lights are fully operational.

    Life Jackets(PFD's): The following USCG approved life jackets were sighted on board: (6) Adult USCG

    Type II, all jackets were in serviceable condition with minimal wear and tear.

    Throwable Type PFD's: The type of USCG approved throwable PFD devices sighted were: (1) USCG

    approved buoyant cushion(s) showing moderate wear and tear.

    Visual Distress Signals: (See Findings & Recommendations Priority I),

    Sound Devices: 12 VDc horn, functional.

  • 8/17/2019 Trawler Sample Report

    25/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 24 of 32

    USCG placards: MARPOL (Garbage) placard is posted. (See Findings & Recommendations

    Priority I)

    Engine ventilation: Power exhaust ventilation blower(s) are installed and fully operational.

    Ignition protection: Yes - all electrical equipment sighted in the engine space appears to be OEM / 

    Ignition protected equipment.

    Photograph(s):

     

    FIRE FIGHTING EQUIPMENT

    Dry Chemical Size I: Four USCG approved USCG approved extinguisher(s) sighted at the followinglocations: Aft cabin, Engine space, Main salon, and V berth. All gauge(s) read full.

    FIRE EQUIPMENT

    OBSERVATION:

    (See Findings & Recommendations Priority I)

    BILGE PUMPS

    ENGINE

    COMPARTMENT:

    Two electric pumps. Rule 12 volt, 2000 GPH Pumps power up and float switches

    turn pumps on.

  • 8/17/2019 Trawler Sample Report

    26/33

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 25 of 32

     

    AFT BILGE: One electric pump. Rule 12 volt, 500 GPH, Pump powers up and float switch turns

    pump on.

    SHOWER & SUMP

    PUMP(S):

    Two pumps one in each water closet. Rule 500 pump in sump tank-not tested.

    MANUAL PUMPS: Henderson manual operated bilge pump. Not tested. (See Findings &

    Recommendations Priority I)

    GROUND TACKLE & WINDLESS

    Anchors & Rodes: A stainless steel 44lb Blue Star anchor is mounted at the anchor platform with an

    undetermined length of raw chain. A Simpson Lawrence windless is mounted on

    the platform and was functional using both the helm and the bow foot controls.

    (See Findings & Recommendations Priority I)

    Photograph(s):

     

    Recommendations:

    SEA TRIAL

    SEA TRIAL DETAILS

    Observations: A formal sea trial was conducted while in route back from the vessel haul out

    returning to the vessels berth. This occurred in parts of the Intra coastal Waterway

    (ICW). Weather conditions were partly cloudy skies, a temperature of 

    approximately 85°F and a moderate chop on the waterway. The vessel was

    operated by the seller. Attending were the buyer Mr. jack Buck, the and attending

    surveyor. The total operational time considered sea trialing was from 12:16 PM and

    completed at 2:34 PM. Total sea trial time was approximately one hours and 15

    minutes.

  • 8/17/2019 Trawler Sample Report

    27/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 26 of 32

    The vessel responded to throttle, and helm manipulation in a normal and

    predictable manner, and visibility from both Helms considered adequate for the

    vessels type. Wide open throttle speed of the engine was observed at approximately

    3500 RPM which resulted in his speed over ground of 9.4 mph. No water leaks into

    the vessel were discovered nor were any abnormal movements or noises emanating

    from the vessel's structure discovered. All observed engine temperatures, oil

    pressures and RPMs as per the vessels gauges appeared to operate at acceptabletemperature ranges and pressure ranges. The auto helm was tested and functioned

    properly.

    Photograph(s):

     

  • 8/17/2019 Trawler Sample Report

    28/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 27 of 32

    INSPECTION RECOMMENDATIONS SUMMARY

    PRIORITY I - SAFETY & REGULATORY RECOMMENDATIONS: 

    (MAY BE MANDATORY)The items listed are required by state laws or federal laws and U.S.C.G. regulations or are considered by the

    attending surveyor to represent unsafe operating conditions. Recommend these items be corrected before next use

    of vessel.

    EXTERIOR HULL, DECK & BOTTOM INSPECTION

    ABOVE WATERLINE HULL, DECK, SUPERSTRUCTURE, HARDWARE & FITTINGS

    Findings:

    Two of the boarding gates do not have functioning locks which could result in accidental man overboard

    situations.

     Recommendations:

    Repair gate locks to make functional.

    HELM STATIONS & NAVIGATION ELECTRONICS

    NAVIGATION ELECTRONICS

    Findings:

    The Furuno Radar display at the pilothouse did not power up.

     Recommendations:

    Repair or replace the radar unit to have a functioning radar display at the helm.

    INBOARD PROPULSION SYSTEM

    MACHINERY

    Findings:

    1. Exhaust hose badly cracked.

    2. Stuffing box cooling hose clamp wasted.

     Recommendations:

    1.Replace exhaust hose and all clamps with new.

    2. Replace wasted hose clamp.

    TANKAGE

    FUEL TANK(S) & PIPING

    Findings:

    1. Fuel fill hose leading form the tanks to the weather deck fills is not labeled USCG Type A hose.

    2. Flexible vented fuel hose is not marked USCG Type A.

     Recommendations:

    1. Replace all fuel fill hose with USCG Type A hose per ABYC H-33.

    2. Replace fuel vent hoses with USCG Type A hose that complies with ABYC H-33.

  • 8/17/2019 Trawler Sample Report

    29/33

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 28 of 32

    SAFETY EQUIPMENT

    U.S.C.G. REQUIRED

    Findings:

    1. Visual distress signals are all expired.

    2. NO Oil Pollution Placard was sighted in or near engine compartment.

     Recommendations:

    1. Replace expired visual distress signals to comply with USCG regulations 33 CFR 175.110 for visualdistress signals prior to using vessel.

    2. USCG regulations state vessels over 26' must have a minimum of a 5" X 8" placard posted. Install a

    USCG approved ''No Discharge of Oil'' placard in or near engine space to comply with - 33 CFR 155.450

    and to avoid a potential large fine.

    FIRE FIGHTING EQUIPMENT

    Findings:

    No current inspection tags sighted on fire fighting equipment. 

     Recommendations:

    Have all fire fighting equipment inspected and certified and do so annually.

    BILGE PUMPS

    Findings:

    Manual bilge pump handle not sighted.

     Recommendations:

    Obtain/locate manual bilge pump handle and make readily available near bilge pump for use in an

    emergency.

    GROUND TACKLE & WINDLESS

    Findings:

    Anchor/rode shackle pins are not properly seized.

     Recommendations:

    Seize anchor rode shackles with galvanized or monel seizing wire to help prevent loss of anchor.

     

    (NOT NORMALLY MANDATORY)These are important maintenance items sighted which in this firm's opinion should be performed. They may also

    include recommendations to conform to current ABYC and NFPA-302 voluntary standards which may not have

    been in effect or may not have been adhered to by the builder when the vessel was constructed. Some of these, if 

    not addressed, could lead to a Priority I safety issue and/or may result in a reduced vessel market value.

    EXTERIOR HULL, DECK & BOTTOM INSPECTION

    HULL, DECK & SUPERSTRUCTURE

    Findings:

    1. The hull bottom has evidence of multiple blisters, most noticeable on the starboard side. When doing

    soundings several areas most notably on the starboard hull had anomalies consistent with delamination.

    2. Moisture meter readings are elevated are elevated on center longitudinal stringers. (No delamination was

    evident).

  • 8/17/2019 Trawler Sample Report

    30/33

    Surveyed for:  - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 29 of 32

     Recommendations:

    1. Have a qualified fiberglass technician inspect the hull bottom and take corrective action to make the hull

    in like new or better condition.

    2. Have a qualified fiberglass technician inspect stringers in the engine room and take corrective action if 

    recommended.

    ABOVE WATERLINE HULL, DECK, SUPERSTRUCTURE, HARDWARE & FITTINGS

    1. Stainless steel fasteners sighted on the transom securing the swim platform showing wastage.

    2. Elevated moisture meters readings taken where stanchions secure to the deck on the aft bridge deck.

    1 Remove all fittings showing signs of wastage and replace with new.

    2. Remove fasteners for the stanchions on the aft bridge deck and re-seal and replace with new fasteners to

    prevent further moisture from getting into the deck.

    BELOW DRAW WATERLINE SKIN FITTINGS, MACHINERY & HARDWARE

    Findings:Large transducer unit is missing speed paddle wheel.

     Recommendations:

    Replace missing paddle wheel.

    CATHODIC PROTECTION

    Findings:

    Bonding system has to have all connections made fast to function. Several locations were sighted with

    unsecured green bonding wires. A unconnected bonding wire was sighted where the port water fill hose is

    located on the port tank.

     Recommendations:Inspect all bonding connections and insure properly connected and terminals are clean.

    HELM STATIONS & NAVIGATION ELECTRONICS

    OTHER ELECTRONICS AND CONTROLS

    Findings:

    Both wiper blades are wasted. The starboard wiper motor sis not power up.

     Recommendations:

    Replace both wiper blades and repair or replace the STBD motor to make operational.

    ELECTRICAL SYSTEMS

    DIRECT CURRENT (D.C). SYSTEMS

    Findings:

    Wire nuts were sighted as connectors below the sole in the forward V berth.

     Recommendations:

    Wiring connections must be wither ring or spade type connections, recommend compliance with ABYC

    E-11.

  • 8/17/2019 Trawler Sample Report

    31/33

    Surveyed for: - 1987 CT Trawler T35  Report file #: 16-065 1987 CT Trawler T35

    Surveyed by: Sun Coast Marine Surveying & Consulting LLC, Tampa FL  Page no: 30 of 32

    TANKAGE

    FRESH WATER TANK(S)

    Findings:

    The water fill hoses show cracks and wastage.

     Recommendations:

    Replace water fill hoses from tank to weather deck with new.

    HOLDING TANK(S) - BLACK WATERFindings:

    The vented loop has hose clamps that are badly wasted.

     Recommendations:

    Replace hose clamps on vented loop system.

    OTHER OBSERVATIONS:These are other less significant maintenance items or observations that if not addressed, could lead to more

    important priority issues and/or could lead to a reduced vessel market value. The cost of addressing these

    recommendations is generally minimal.

    EXTERIOR HULL, DECK & BOTTOM INSPECTIONABOVE WATERLINE HULL, DECK, SUPERSTRUCTURE, HARDWARE & FITTINGS

    Several ADWL fittings show wastage from UV.

    Replace all damaged ADWL thru hull fittings.

    CABIN INTERIOR APPOINTMENTS

    ACCOMMODATIONS

    Findings:

    The stove and oven burners would not ignite when tested.

     Recommendations:

    Repair or replace stove / oven to make operational.

  • 8/17/2019 Trawler Sample Report

    32/33

    CONDITION & VALUE REPORT SUMMARY

    VALUATION:SAMPLE EXTRACTEDINFORMATIONREPORT

     

  • 8/17/2019 Trawler Sample Report

    33/33

     

    CERTIFICATION:

    Acting on behalf of Sun Coast Marine Surveying & Consulting LLC, the undersigned surveyor certifies that to the best of my

    knowledge and belief: That the statements of fact in this report are true and correct. The reported analysis, opinions andconclusions are limited only by the reported assumptions and limiting conditions at the time of inspection and are mypersonal, impartial and unbiased professional analysis, opinions and conclusions. I have no present or prospectiveinterest in the property that is the subject of this report and no personal interest with respect to the parties involved. Ihave no bias with the respect to the property that is the subject of this report or to the parties involved with this

    assignment. My engagement in this assignment was not contingent upon development or reporting of apredetermined value or direction in value that favors the cause of the client or seller, the amount of the value opinion,the attainment of a stipulated result, or the occurrence of a subsequent event directly related to the intended use ofthe report content including the appraisal.

    REPORT SUBMITTED WITHOUT PREJUDICE 

    Sun Coast Marine Surveying and Consulting LLC 

       J Chet Stephens  By:

    Operating Manager

    J. Chet Stephens, SAMS-SA