transmittance, scraping and maximum radii for mice stepvi

29
MICE analysis meeting - ( 21/09/2006) 1 Transmittance, scraping and maximum radii for MICE STEPVI M. Apollonio – University of Oxford

Upload: vladimir-howe

Post on 02-Jan-2016

32 views

Category:

Documents


0 download

DESCRIPTION

Transmittance, scraping and maximum radii for MICE STEPVI. M. Apollonio – University of Oxford. parameters used in simulation (ICOOL) TRANSMITTANCE Define a VACUUM channel (NO ABS, NO RF) and a large aperture upstream/downstream channels 40cm + vacuum channel + 40cm + 90cm - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

1

Transmittance, scraping and maximum radii for MICE STEPVI

M. Apollonio – University of Oxford

Page 2: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

2

parameters used in simulation (ICOOL) TRANSMITTANCE

Define a VACUUM channel (NO ABS, NO RF) and a large aperture upstream/downstream channels

40cm + vacuum channel + 40cm + 90cm Evaluate amplitude upstream/downstream and do the

ratio=transmission/amplitude Max radius (effect of scraping) and cooling

Use the realistic channel (real radii) Select throughoing muons Record the max radius for every z-slice

Parameters used in ICOOL simulation Pz=240, 200, (170) MeV/c with no gaussian spread initial emittances: 0.1, 0.3, 0.6, 1.0, 2.0, 3.0 (cm rad) 40000 generated muons per initial emittance 128 positions along Z to study the amplitudes of the beam (Single

Particle Emittance)

Page 3: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

3

NuNdT=Nd/Nu

Scheme for transmission study:No selection on muonsRatio between downstream and upstream particles

Scheme for max radius and cooling study:selection on muons only throughgoing acceptedSearch for max value of radial distribution

R=40 cm R=40 cm

R=90 cm

Zu=-5.2 m Zd=-5.2 m

Page 4: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

4

CAVEAT:

The RF is designed to work with a beam of ~200 MeV/c

When working with 240/170 MeV/c the RF config should be changed properly

I did it “by hand” changing the phase and the peak voltage

Discovered yesterday

Page 5: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

5

N.B. RF @ 200 MeV/c: 8.74 MV/m – 90 deg P

(G

eV/c

)

Z (m)

Still not perfect …

9.1 MV/m – ph.shift=30 deg

Pz=170 MeV/cemi=1 mm rad

Z (m)

P (

GeV

/c)

8.74 MV/m – ph.shift=130 deg

Pz=240 MeV/cemi=1 mm rad8.74 MV/m

ph.shift=90

Page 6: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

6

beam maximum radius + cooling

Page 7: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

7

0.1 cm rad0.3 cm rad0.6 cm rad1.0 cm rad2.0 cm rad3.0 cm rad

PZ=200 MeV/c, abs=42 cm

MICE profilein ICOOL sim

Page 8: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

8

=0.1cm rad

=0.3cm rad

downstream PZ=200 MeV/c, abs=42 cm

ratio

ratio

40K

heating

cooling

Page 9: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

9

=1.0 cm rad

=0.6cm rad

PZ=200 MeV/c, abs=42 cm

Page 10: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

10

=2.0 cm rad

=3.0 cm rad

PZ=200 MeV/c, abs=42 cm

Page 11: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

11

0.1 cm rad0.3 cm rad0.6 cm rad1.0 cm rad2.0 cm rad3.0 cm rad

PZ=240 MeV/c, abs=42 cm

Page 12: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

12

=0.1cm rad

downstream

=0.3cm rad

PZ=240 MeV/c, abs=42 cm

40K

Page 13: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

13

e=0.6cm rad

e=1.0cm rad

PZ=240 MeV/c, abs=42 cm

Page 14: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

14

e=3.0cm rad

e=2.0cm rad

PZ=240 MeV/c, abs=42 cm

Page 15: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

15

0.1 cm rad0.3 cm rad0.6 cm rad1.0 cm rad2.0 cm rad3.0 cm rad

PZ=170 MeV/c, abs=15 cm

Page 16: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

16

=0.1cm rad

downstream

=0.3cm rad

PZ=170 MeV/c, abs=15 cm

40K

Page 17: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

17

=0.6cm rad

downstream

=1.0cm rad

PZ=170 MeV/c, abs=15 cm

Page 18: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

18

=2.0 cm rad

downstream

=3.0 cm rad

PZ=170 MeV/c, abs=15 cm

Page 19: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

19

transmittance

Page 20: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

20

PZ=200 MeV/c, abs=42 cm=0.1cm rad

=0.3cm rad

Page 21: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

21

PZ=200 MeV/c, abs=42 cme=0.6cm rad

e=1.0cm rad

Page 22: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

22

PZ=200 MeV/c, abs=42 cme=2.0cm rad

e=3.0cm rad

Page 23: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

23

PZ=170 MeV/c, abs=15 cm

!!!! 4K !!!!

Page 24: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

24

PZ=170 MeV/c, abs=15 cm

Page 25: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

25

PZ=170 MeV/c, abs=15 cm

Page 26: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

26

PZ=240 MeV/c, abs=42 cm

Page 27: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

27

PZ=240 MeV/c, abs=42 cm

Page 28: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

28

PZ=240 MeV/c, abs=42 cm

Page 29: Transmittance, scraping and maximum radii for MICE STEPVI

MICE analysis meeting - (21/09/2006)

29