transforming the future of power electronics planar ... a4 24pp brochure.pdf · planar windings are...

24
Transforming the Future of Power Electronics Planar Transformers & Inductors www.himag.co.uk

Upload: others

Post on 12-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Transforming the Future of Power Electronics

    Planar Transformers & Inductors www.himag.co.uk

    himag brochure cover final.indd 1 24/04/2012 16:40

  • Company ProfileHimag Planar Ltd. has pioneered planar transformer technology from the UK since 1996.Our world-leading design engineering team have developed custom planar transformers from 35W to 50kW in a single transformer component and inductors at 350A, as well as fully developing custom power converters utilising planar magnetics technology. This design facility is an essential part of the Himag Planar organisation as most products are custom designed.

    Himag Planar offers a one-stop planar transformer and inductor service; from your initial design concept right through to volume production. We aim to work alongside our customer throughout the design lifecycle, from the drawing board to the finished product. Flexibility is our ethos: we design custom magnetic components and systems to suit your specific requirements, rather than expecting you to adapt your design to accommodate a standard part.

    Awards

    Himag Planar Limited won the UK finals of the prestigious Shell Springboard Award for the best low carbon business idea in the UK. The award was given at a ceremony in central London to recognise the innovation of its planar transformer which dramatically increases energy efficiency in high-frequency power electronic products across the world. As an invisible but integral component of millions of electrical devices, the Planar Transformer could have a huge impact on our domestic and global carbon footprints.

    The Shell Springboard program has awarded over £1.6 million to 43 UK-based small businesses and this year celebrates its fifth anniversary. Eight companies have been given no-strings awards of £40,000 each at regional events in February. Himag Planar impressed the UK final judging panel, and out of the 6 UK finalists came top to gain the further title of Shell Springboard UK winner.

    The judging panel comprised Tom Delay of the Carbon Trust, Lord Oxburgh, Ben Goldsmith of Wheb Ventures and Dr Douglas Parr, Chief Scientist, Greenpeace. The judges were particularly impressed with the potential of Himag planar transformers in the solar power, electric vehicles and aerospace markets.

    Dean Curran, Managing Director of Himag Planar, said: “The financial boost from the Shell Springboard award will unlock the huge market potential for our energy efficient transformers - a fundamental component of thousands of electrical devices. We can now realise our ambition of providing a technology which tackles energy inefficiency at the very core to manufacturers far and wide. Without this award we wouldn’t be able to grow as fast but, above all, it’s the accolade of being named the Shell Springboard overall UK Winner which gives us real credibility in the eyes of our customers and potential investors alike.”

    Planar Transformers

    www.himag.co.uk1

  • Planar TransformersPlanar transformers are suited to high frequency switching applications, with a typical switching frequency of 5kHz - 500kHz. The fundamental difference between planar transformers and traditional wire-wound transformers is the planar’s use of flat copper windings, resulting in higher efficiency. Planar Windings are constructed using flat copper layers (‘lead-frames’) or printed circuit boards (PCBs) to form a laminate style winding construction, which are then sandwiched between small, light-weight planar ferrite cores. The result is a compact, high power density planar transformer that is typically around 30% of the volume and weight of its conventional wire-wound equivalent. As a result, bulky three dimensional wire-wound transformers will no longer constrain your design.

    Advantages Applications• High Efficiency (>99%)

    • Low profile (

  • Product Range Overview

    OUTPUTPOWER FREQUENCY

    INPUT/OUTPUT VOLTAGE

    OUTPUTCURRENT PAGE

    131000A MAX1000V MAX1MHz MAX30kW MAXSIZE 1080 ≥ ≥ ≥

    11300A MAX1000V MAX2MHz MAX10kW MAXSIZE 510 ≥ ≥ ≥

    12750A MAX1000V MAX1MHz MAX15kW MAXSIZE 540 ≥ ≥ ≥

    10500A MAX1000V MAX2MHz MAX10kW MAXSIZE 500 ≥ ≥ ≥

    9300A MAX750V MAX3MHz MAX6.5kW MAXSIZE 350 ≥ ≥ ≥

    8400A MAX600V MAX3MHz MAX5kW MAXSIZE 310 ≥ ≥ ≥

    7200A MAX500V MAX3MHz MAX2kW MAXSIZE 230 ≥ ≥ ≥

    6150A MAX600V MAX3MHz MAX2kW MAXSIZE 225 ≥ ≥ ≥

    5120A MAX500V MAX3MHz MAX1.5kW MAXSIZE 195 ≥ ≥ ≥

    4100A MAX500V MAX3MHz MAX1kW MAXSIZE 130 ≥ ≥ ≥

    141200A MAX1000V MAX1MHz MAX≥ ≥ ≥50kW MAXSIZE 1200

    151200A MAX1000V MAX1MHz MAX≥ ≥ ≥80kW MAXSIZE 2400

    161200A MAX1000V MAX1MHz MAX≥ ≥ ≥120kW MAXSIZE 3600

    Transformers

    Indu

    ctor

    s

    www.himag.co.uk

    [1]

    PRODUCT RANGE OVERVIEW TRANSFORMERS

    OUTPUT POWER

    FREQUENCY INPUT/ OUTPUT

    VOLTAGE OUTPUT

    CURRENT PAGE

    SIZE 130 1kW MAX ≤3MHz MAX ≤500V MAX ≤100A MAX 4

    SIZE 195 1.5kW max ≤3MHz MAX ≤500V MAX ≤120A MAX 5

    SIZE 225 2kW max ≤3MHz MAX ≤500V MAX ≤150A MAX 6

    SIZE 230 2kW max ≤3MHz MAX ≤500V MAX ≤200A MAX 7

    SIZE 310 5kW max ≤3MHz MAX ≤600V MAX ≤400A MAX 8

    SIZE 350 6.5kW max ≤3MHz MAX ≤750V MAX ≤300A MAX 9

    SIZE 500 12kW max ≤2MHz MAX ≤1000V MAX ≤500A MAX 10

    SIZE 540 15kW max ≤1MHz MAX ≤1000V MAX ≤750A MAX 11

    SIZE 560 10kW max ≤2MHz MAX ≤1000V MAX ≤500A MAX 12

    SIZE 1080 30kW max ≤1MHz MAX ≤1000V MAX ≤1000A MAX 13

    SIZE 1200 50kW max ≤1MHz MAX ≤1000V MAX ≤1200A MAX 14

    INDUCTORS

    www.himag.co.uk3

    Planar Transformers

    Size: 130Size: 195Size: 225Size: 230Size: 310Size: 350Size: 500Size: 540Size: 560Size: 1080Size: 1200Size: 2400Size: 3600

  • SIZE 130 1kW MAX POWER

    OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    1kW MAX

    Custom Transformer Parameters

    500V MAX 3MHz MAX 500V MAX 100A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    175W253W729W

    100V - 300V20V - 30V

    300V - 400V

    100kHz250kHz150kHz

    350V230V27V

    0.5A1.1A27A

    11:381:2032:7

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    45g (typ.)

    www.himag.co.uk

    [1]

    SIZE 130 - 1KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    1kW MAX 500V MAX 3MHz MAX 500V MAX 100A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    175W 100 – 300 100kHz 350V 0.5A 11:38

    253W 20V – 30V 250kHz 230V 1.1A 1:20

    729W 300V – 400V 150kHz 27V 27A 32:7

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 45g (typ.)

    INDUCTOR SELECTION

    50mm MAX

    32m

    m M

    AX

    11

    mm

    MIN

    20

    mm

    MA

    X

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    4www.himag.co.uk

    Planar Transformers

  • www.himag.co.uk

    [1]

    SIZE 195 - 1.5KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    1.5kW MAX 500V MAX 3MHz MAX 500V MAX 120A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    420W 20V – 40V 125kHz 28V 15A 2:6

    800W 10V – 18V 100kHz 400V 2A 2:88

    1.1kW 90V 250kHz 28V 40A 5:2

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 85g (typ.)

    INDUCTOR SELECTION

    60mm MAX

    38m

    m M

    AX

    12

    mm

    MIN

    20

    mm

    MA

    X

    OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    1.5kW MAX

    Custom Transformer Parameters

    500V MAX 3MHz MAX 500V MAX 120A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    420W800W1.1kW

    20V - 40V10V - 18V

    90V

    125kHz100kHz250kHz

    28V400V28V

    15A2A

    40A

    2:62:885:2

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    85g (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    SIZE 195 1.5kW MAX POWER

    www.himag.co.uk5

    Planar Transformers

  • www.himag.co.uk

    [1]

    SIZE 225 - 2.0KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    2kW MAX 500V MAX 3MHz MAX 500V MAX 150A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    1000W 100V – 200V 75kHz 40V 25.0A 5:2

    1.5kW 300V – 400V 100kHz 180V 8.30A 8:5

    2.0kW 375V – 480V 250kHz 420V 4.75A 5:7

    TOPOLOGIES

    • Full Bridge • Half-Bridge • Flyback • Forward

    • Resonant • Push Pull • Boost • Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 110g (typ.)

    INDUCTOR SELECTION

    OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    2kW MAX

    Custom Transformer Parameters

    600V MAX 3MHz MAX 600V MAX 150A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    1kW2kW2kW

    100V - 200V300V - 400V375V - 480V

    75kHz100kHz250kHz

    40V180V420V

    25.0A8.30A4.75A

    5:28:55:7

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    110g (typ.)

    Topologies•Full Bridge

    •Resonant

    •Half-Bridge

    •Push Pull

    •Flyback

    •Boost

    •Forward

    •Buck

    Inductor Selection

    SIZE 225 2kW MAX POWER

    www.himag.co.uk

    [1]

    SIZE 225 - 2.0KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    2kW MAX 500V MAX 3MHz MAX 500V MAX 150A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    1000W 100V – 200V 75kHz 40V 25.0A 5:2

    1.5kW 300V – 400V 100kHz 180V 8.30A 8:5

    2.0kW 375V – 480V 250kHz 420V 4.75A 5:7

    TOPOLOGIES

    • Full Bridge • Half-Bridge • Flyback • Forward

    • Resonant • Push Pull • Boost • Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 110g (typ.)

    INDUCTOR SELECTION

    6www.himag.co.uk

    Planar Transformers

  • www.himag.co.uk

    [1]

    SIZE 230 - 2KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE

    FREQUENCY OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    2kW MAX 500V MAX 3MHz MAX 500V MAX 200A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    400W 12V – 24V 60kHz 300V 1.3A 2:50

    1.4kW 60V – 90V 100kHz 14V 100A 4:2

    1.5kW 350V – 420V 75kHz 48V 30A 21:3

    TOPOLOGIES

    • Full Bridge • Half-Bridge • Flyback • Forward

    • Resonant • Push Pull • Boost • Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 130g (typ.)

    INDUCTOR SELECTION

    65mm MAX

    43

    mm

    MA

    X

    15

    mm

    MIN

    2

    4m

    m M

    AX

    OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    2kW MAX

    Custom Transformer Parameters

    500V MAX 3MHz MAX 500V MAX 200A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    400W1.4kW1.5kW

    12V 24V60V - 90V

    350V - 420V

    60kHz100kHz75kHz

    300V14V48V

    1.3A100A30A

    2:504:2

    21:3

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    130g (typ.)

    Topologies•Full Bridge

    •Resonant

    •Half-Bridge

    •Push Pull

    •Flyback

    •Boost

    •Forward

    •Buck

    Inductor Selection

    SIZE 230 2kW MAX POWER

    www.himag.co.uk7

    Planar Transformers

  • www.himag.co.uk

    [1]

    SIZE 310 - 5KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    5kW MAX 600V MAX 3MHz MAX 600V MAX 400A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    2.4kW 300V - 400V 100kHz 12V 200A 18:1

    3.6kW 100V – 150V 200kHz 300V 12A 3.9

    4kW 400V 50kHz 500V 8A 21:26

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 300g (typ.)

    INDUCTOR SELECTION

    100mm MAX

    58m

    m M

    AX

    15

    mm

    MIN

    40

    mm

    MA

    X

    OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    5kW MAX

    Custom Transformer Parameters

    600V MAX 3MHz MAX 600V MAX 400A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    2.4kW3.6kW4kW

    300V - 400V100V - 150V

    400V

    100kHz200kHz50kHz

    12V300V500V

    200A12A8A

    18:13:9

    21:26

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    300g (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    SIZE 310 5kW MAX POWER

    8www.himag.co.uk

    Planar Transformers

  • OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    6.5kW MAX

    Custom Transformer Parameters

    750V MAX 3MHz MAX 750V MAX 300A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    570W1.8kW4.8kW

    36V200V - 500V130V - 150V

    100kHz100kHz75kHz

    190V18V24V

    3A100A200A

    4:24+411:14:2

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    200g (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    SIZE 350 6.5kW MAX POWER

    www.himag.co.uk

    [1]

    SIZE 350 - 6.5KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    6.5kW MAX 750V MAX 3MHz MAX 750V MAX 300A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    570W 36V 100kHz 190VDC 3A 4:24+4

    1.8kW 200V – 500V 100kHz 18V 100A 11:1

    4.8kW 130 – 150V 75kHz 24V 200A 4:2

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 200g (typ.)

    INDUCTOR SELECTION

    70mm MAX

    51m

    m M

    AX

    15

    mm

    MIN

    24

    m M

    AX

    www.himag.co.uk9

    Planar Transformers

  • OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    10kW MAX

    Custom Transformer Parameters

    1000V MAX 2MHz MAX 1000V MAX 500A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    3.5kW5.4kW9kW

    420V - 622V350V - 375V780V - 800V

    100kHz75kHz

    130kHz

    29V120V350V

    120A45A25A

    12:1+110:416:8

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    400g (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    www.himag.co.uk

    [1]

    SIZE 500 - 12KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE

    FREQUENCY OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    12kW MAX 1000V MAX 2MHz MAX 1000V MAX 500A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE

    FREQUENCY OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    3.5kW 420V – 622V 100kHz 29V 120A 12:1+1

    5.4kW 350V – 375V 75kHz 120V 45A 10:4

    9kW 780V - 800V 130kHz 350V 25A 16:8

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 400g (typ.)

    INDUCTOR SELECTION

    118mm MAX

    65m

    m M

    AX

    17

    mm

    MIN

    40

    mm

    MA

    X

    SIZE 500 10kW MAX POWER

    10www.himag.co.uk

    Planar Transformers

  • OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    10kW MAX

    Custom Transformer Parameters

    1000V MAX 2MHz MAX 800V MAX 300A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    3.0kW6.0kW10kW

    400V - 600V550V - 800V600V - 800V

    50kHz100kHz200kHz

    40V200V100V

    75A30A

    100A

    9:15:2

    7:1+1

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    4kVrms

    2.5kVrms

    2.5kVrms

    20kHz-3MHz

    430g (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    www.himag.co.uk

    [1]

    SIZE 560 - 10KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    10kW MAX 1000V MAX 2MHz MAX 800V MAX 300A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    3.0kW 400V – 600V 50kHz 40V 75A 9:1

    6.0kW 550V – 800V 100kHz 200V 30A 5:2

    10kW 600V - 800V 200kHz 100V 100A 7:1+1

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 430g (typ.)

    INDUCTOR SELECTION

    SIZE 510 10kW MAX POWER

    www.himag.co.uk

    [1]

    SIZE 560 - 10KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    10kW MAX 1000V MAX 2MHz MAX 800V MAX 300A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    3.0kW 400V – 600V 50kHz 40V 75A 9:1

    6.0kW 550V – 800V 100kHz 200V 30A 5:2

    10kW 600V - 800V 200kHz 100V 100A 7:1+1

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 430g (typ.)

    INDUCTOR SELECTION

    70mm MIN108mm MAX

    64m

    m M

    AX

    18m

    m M

    IN45

    mm

    MA

    X

    Size 510

    www.himag.co.uk11

    Planar Transformers

  • OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    15kW MAX

    Custom Transformer Parameters

    1000V MAX 1MHz MAX 1000V MAX 750A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    9kW10kW

    13.5kW

    450V - 650V520V - 750V375V - 425V

    100kHz50kHz60kHz

    250V400V225V

    37A25A60A

    16:614:1212:8

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    5.5kVrms

    2.75kVrms

    2.75kVrms

    20kHz-1MHz

    1kg (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    www.himag.co.uk

    [1]

    SIZE 540 - 15KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    15kW MAX 1000V MAX 1MHz MAX 1000V MAX 750A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    9kW 450V – 650V 100kHz 250V 37A 16:6

    10kW 520V - 750V 50kHz 400V 25A 14:12

    13.5kW 375V – 425V 60kHz 225V 60A 12:8

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 5.5kVrms

    Primary – Core 2.75kVrms

    Secondary – Core 2.75kVrms

    Switching Frequencies 20kHz-1MHz

    Weight 1kg (typ.)

    INDUCTOR SELECTION

    SIZE 540 15kW MAX POWER112mm MIN 135mm MAX

    102m

    m M

    AX

    22m

    m M

    IN48

    mm

    MA

    X

    12www.himag.co.uk

    Planar Transformers

  • OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    30kW MAX

    Custom Transformer Parameters

    1000V MAX 1MHz MAX 1000V MAX 1000A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    15kW17kW30kW

    583V - 745V400V - 800V540V - 700V

    75kHz45kHz

    100kHz

    65V200V350V

    230A85A90A

    9:116:8

    16:6+6

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    5.5kVrms

    2.75kVrms

    2.75kVrms

    20kHz-1MHz

    2kg (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    www.himag.co.uk

    [1]

    SIZE 1080 - 30KW MAX POWER

    POSS. MIN DIMENSIONS 194MM X 102MM X 22.5MM CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    30kW MAX 1000V MAX 1MHz MAX 1000V MAX 1000A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    15kW 583V – 745V 75kHz 65V 230A 9:1

    17kW 400V – 800V 45kHz 200V 85A 16:8

    30kW 540V – 700V 100kHz 350V 90A 16:6+6

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 5.5kVrms

    Primary – Core 2.75kVrms

    Secondary – Core 2.75kVrms

    Switching Frequencies 20kHz-1MHz

    Weight 2kg (typ.)

    INDUCTOR SELECTION

    219MM MAX

    135M

    M M

    AX

    IN

    C. H

    EA

    TS

    INK

    58

    MM

    MA

    X

    SIZE 1080 30kW MAX POWER

    www.himag.co.uk

    [1]

    SIZE 1080 - 30KW MAX POWER

    POSS. MIN DIMENSIONS 194MM X 102MM X 22.5MM CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    30kW MAX 1000V MAX 1MHz MAX 1000V MAX 1000A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    15kW 583V – 745V 75kHz 65V 230A 9:1

    17kW 400V – 800V 45kHz 200V 85A 16:8

    30kW 540V – 700V 100kHz 350V 90A 16:6+6

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 5.5kVrms

    Primary – Core 2.75kVrms

    Secondary – Core 2.75kVrms

    Switching Frequencies 20kHz-1MHz

    Weight 2kg (typ.)

    INDUCTOR SELECTION

    219MM MAX

    135M

    M M

    AX

    IN

    C. H

    EA

    TS

    INK

    58

    MM

    MA

    X

    www.himag.co.uk13

    Planar Transformers

  • OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    50kW MAX

    Custom Transformer Parameters

    1000V MAX 1MHz MAX 1000V MAX 1200A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    15kW25kW50kW

    500V - 800V850V - 1000V800V - 1000V

    75kHz100kHz200kHz

    40V350V200V

    375A72A

    250A

    12:1+112:55:1

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    5.5kVrms

    2.75kVrms

    2.75kVrms

    20kHz-3MHz

    1.5kg (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    SIZE 1200 50kW MAX POWER

    www.himag.co.uk

    [1]

    SIZE 1200 - 50KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    50kW MAX 1000V MAX 2MHz MAX 1000V MAX 1500A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    15kW 500V – 800V 75kHz 40V 375A 12:1+1

    25kW 850V – 1000V 100kHz 350V 72A 12:5

    50kW 800V - 1000V 200kHz 200V 250A 5:1

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 1.5kg (typ.)

    INDUCTOR SELECTION

    www.himag.co.uk

    [1]

    SIZE 1200 - 50KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    50kW MAX 1000V MAX 2MHz MAX 1000V MAX 1500A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    15kW 500V – 800V 75kHz 40V 375A 12:1+1

    25kW 850V – 1000V 100kHz 350V 72A 12:5

    50kW 800V - 1000V 200kHz 200V 250A 5:1

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 1.5kg (typ.)

    INDUCTOR SELECTION

    177mm MIN237mm MAX

    153m

    m M

    AX

    40m

    m M

    IN62

    mm

    MA

    X

    14www.himag.co.uk

    Planar Transformers

  • Planar Transformers

    www.himag.co.uk15

    OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    80kW MAX

    Custom Transformer Parameters

    1000V MAX 1MHz MAX 1000V MAX 1200A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    80kW 650V 20kHz 400V 200A 13:10

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    5.5kVrms

    2.75kVrms

    2.75kVrms

    20kHz-3MHz

    5kg (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    SIZE 2400 80kW MAX POWER

    www.himag.co.uk

    [1]

    SIZE 1200 - 50KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    50kW MAX 1000V MAX 2MHz MAX 1000V MAX 1500A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    15kW 500V – 800V 75kHz 40V 375A 12:1+1

    25kW 850V – 1000V 100kHz 350V 72A 12:5

    50kW 800V - 1000V 200kHz 200V 250A 5:1

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 1.5kg (typ.)

    INDUCTOR SELECTION

    153m

    m M

    AX

    40m

    m M

    IN62

    mm

    MA

    X

    Size 2400

    293mm

  • Planar Transformers

    16www.himag.co.uk

    OUTPUTPOWER

    INPUTVOLTAGE FREQUENCY

    OUTPUTVOLTAGE

    OUTPUTCURRENT

    TURNSRATIO

    PRIMARYINDUCTANCE

    120kW MAX

    Custom Transformer Parameters

    1000V MAX 1MHz MAX 1000V MAX 1200A MAX CUSTOM CUSTOM

    Example Transformer SpecificationsOUTPUT POWER INPUT VOLTAGE FREQUENCY OUTPUT VOLTAGE

    120kW 750 - 820V 20kHz 685V 175A 15:13

    OUTPUT CURRENT TURNS RATIO

    Additional Technical InformationIsolation Voltage:

    Primary - Secondary

    Primary - Core

    Secondary - Core

    Switching Frequencies

    Weight

    5.5kVrms

    2.75kVrms

    2.75kVrms

    20kHz-3MHz

    10kg (typ.)

    Topologies•Full Bridge

    •Push Pull

    •Half-Bridge

    •Resonant

    •Flyback

    •Forward

    •Boost

    •Buck

    Inductor Selection

    SIZE 3600 120kW MAX POWER

    www.himag.co.uk

    [1]

    SIZE 1200 - 50KW MAX POWER

    CUSTOM TRANSFORMER PARAMETERS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    PRIMARY INDUCTANCE

    50kW MAX 1000V MAX 2MHz MAX 1000V MAX 1500A MAX CUSTOM CUSTOM

    EXAMPLE TRANSFORMER SPECIFICATIONS

    OUTPUT POWER

    INPUT VOLTAGE FREQUENCY

    OUTPUT VOLTAGE

    OUTPUT CURRENT

    TURNS RATIO

    15kW 500V – 800V 75kHz 40V 375A 12:1+1

    25kW 850V – 1000V 100kHz 350V 72A 12:5

    50kW 800V - 1000V 200kHz 200V 250A 5:1

    TOPOLOGIES

    Full Bridge Half-Bridge Flyback Boost

    Push Pull Resonant Forward Buck

    ADDITIONAL TECHNICAL INFORMATION

    Isolation Voltage:

    Primary – Secondary 4kVrms

    Primary – Core 2.5kVrms

    Secondary – Core 2.5kVrms

    Switching Frequencies 20kHz-3MHz

    Weight 1.5kg (typ.)

    INDUCTOR SELECTION

    153m

    m M

    AX

    40m

    m M

    IN62

    mm

    MA

    X

    Size 3600

    348mm

  • Auxiliary-Power Range

    Custom Auxiliary Planar Transformers

    Himag Planar manufactures a standard range of auxiliary power PCB transformers in the 10W to 55W power range. Designed specifically to offer high-voltage, low-current solutions, these planar transformers are ideal for multiple output auxiliary PSUs, in single and three phase mains powered systems:

    Himag Planar also offers custom PCB auxiliary planar transformers where extreme custom capability is required. The table below is an example of a high winding count, multiple 17 output auxiliary PSU transformer for multiple axis motor drives.

    Size A 35W

    POWER RANGE FREQ RANGE TOPOLOGY INSULATION PRIMARYTEMP.

    10W - 35WPSU Output 1

    5V @ 2APSU Output 2 & 3

    +15V @ 0.2APSU Output 424V @ 0.75A

    50kHz Flyback 5kV -10 - 95 0C 250V - 900V

    Size B 55W

    POWER RANGE FREQ RANGE TOPOLOGY INSULATION PRIMARYTEMP.

    20W - 55WPSU Output 1

    5V @ 2APSU Output 2 & 3

    +15V @ 0.25APSU Output 424V @ 1.5A

    50kHz Flyback 5kV -10 - 95 0C 250V - 900V

    POWER RANGE FREQ RANGE TOPOLOGY INSULATION PRIMARYTEMP.

    10W - 55WPSU Output 1

    5V @ 1.5A +15V @ 0.2A 24V @ 0.75A 8V @ 0.1A 15V @ 0.25APSU Output 2 & 3 PSU Output 4 PSU Output 5 PSU Output 6 to 17

    50kHz Flyback 5kV -10 - 95 0C 250V - 900V

    www.himag.co.uk17

    Planar Transformers

  • Multi-Pin PCBMounting

    Horizontal PCBMounting

    Vertical PCBMounting

    BoltedConnections

    CustomisedExtendedLead-Frames

    Bolted and SolderedConnections

    Power SolderedLeads

    Fly Leads

    Vertical PCB to PCB

    Heatsinks

    TerminationsHimag Planar offers a wide range of connection/termination options for its transformers. Some examples of existing designs are shown below. The Himag Planar design and are happy to provide any custom termination arrangement.

    Himag Planar offers a wide range of heatsink and baseplate options for its transformers. Some examples of existing designs are shown below. The Himag Planar design and are happy to provide any custom heatsink or baseplate arrangement.

    www.himag.co.uk 18

    Planar Transformers

  • Quality

    005

    ISO 9001:2008

    Himag Planar has been accredited under the ISO 9001:2000 system for a number of years and IS0 9000:2008 accreditation since 2010.

    UL (UNDERWRITERS LABORATORIES)

    Himag Planar products are manufactured to our own UL Certified Class F (+155oC) Insulation System (UL File No. E208723)

    BRITISH

    Most of our business activities, including R&D and low volume manufacturing (

  • Custom DesignHimag Planar have been providing planar power solutions for over 13 years, offering an array of products and services to the power electronics market. We appreciate that not all designs fit into our standard product ranges and that’s why we also offer a custom design service.

    We undertake projects ranging from discrete planar components to fully integrated power converters. The following are some examples of projects we have completed.

    Power ConverterThe example shown below is a fully integrated planar magnetic, high voltage DC-DC Converter for a telecoms application. This is a resonant based design operating at a switching frequency of 20kHz. The converter runs from a low voltage DC Bus and is capable of delivering a high voltage output of up to 4kV @ 1Adc.

    The main power transformer and output inductors are embedded within a single multilayer PCB. All other discrete components are mounted as either SMT or PTH devices on the same multilayer layer PCB:

    •Rectification Diodes (SMT)

    •Filter Capacitors (PTH)

    •Feedback components (PTH)

    •Protection Devices (PTH)

    The incorporation of the magnetic components into a single PCB provides a compact solution with excellent repeatability. It also eases manufacture as there is less assembly time associated with its construction.

    www.himag.co.uk 20

    Planar Transformers

  • Integrated MagneticsWhere size and space are a real issue, integrated magnetics can provide an alternative solution to the conventional discrete component approach.Himag Planar has experience designing this type of product and this particular example, shown to the right, shows an integrated Transformer and Output Inductor assembly. This solution embeds a transformer with two inductors onto the same PCB assembly. These three components are configured for a current doubler output providing 5V @ 60Adc.

    Retro FitNon-planar cores are often used when retro-fitting a planar transformer into a conventional space. Himag Planar has been asked on several occasions to design a retrofit planar transformer to replace a conventional transformer that ran too hot. A retro-fit planar transformer offers a combination of advantages, in particular the interleaving that a planar transformer construction allows, as well as a reduction of skin effect. Retro-fitting can present its own problems in terms of core selection and lead-frame/PCB design options, but has nevertheless yielded benefits. The reduction in thermal conduction area can be detrimental but as long as careful attention is paid to the interleave structure the majority of the benefits are still achievable.

    High Voltage Isolation Transformers / FlexibilityHigh voltage isolation (up to 20kV) can present a challenge to any insulation system. Himag Planar overcome this by isolating one set of windings using HV Insulated wire. This allows the use of planar leadframes and PCB’s for the other winding set; greatly improving transformer size and performance. In addition Himag Planar also design transformers using multiple ferrite cores which greatly improves the effective area of the transformer. We design our own custom bobbins and fixtures to fit any combination.

    www.himag.co.uk21

    Planar Transformers

  • Contact UsHeadquarters

    Himag Planar Magnetics Ltd.Unit A, The Aquarius Centre,Edison Close, Waterwells Business Park,Quedgeley, Glos.GL2 2FNUnited Kingdom

    Tel: +44 (0) 1452 72 23 51

    Fax: +44 (0) 1452 88 13 60

    E-mail: [email protected]

    005

    www.himag.co.uk

  • Himag Planar Magnetics Ltd.Unit A, The Aquarius Centre, Edison Close, Waterwells Business Park, Quedgeley,

    Glos. GL2 2FN United Kingdom.

    www.himag.co.uk