These dimmers can be used to dim lights from several locations. They are suitable for dimming mains and/or dimmable transformer low voltage lamps. Functions and Special features Slim buttons give an easy press action. Pressing the button dims or brightens the light to any level. A quick press switches off. Another press returns the lamp to its previous brightness. All versions are suitable for dimming most mains dimmable LED lamps and fittings and mains halogen lamps. Quiet operation. The soft start feature prolongs the lamp life. Some LED lamps may require a small resistive load (order code RESLOADE, see page 86) to enable smooth dimming. Multi-way switching and dimming can be achieved from any position only by using the complementary DANLERS slave switches. These grid dimmer modules fit any position on the appropriate grid or plate system. 38 25 50 front side Dimmer module for Eurodata plates. Dimmer module for Crabtree grid. 38 24 51 front side 34 Dimmer module for MK Grid Plus. 24 59 front side 30 34 58 D I M M I N G L E D D I M M I N G M U L T I P O I N T Q U I E T O P E R A T I O N TRAILING EDGE DIMMERS Quiet grid dimmer modules Dimensions in mm

Upload: trinhngoc

Post on 22-Jun-2018

231 views

Category:

Documents


0 download

TRANSCRIPT

These dimmers can be used to dim lights from several locations. They are suitable for dimming mains and/or dimmable transformer low voltage lamps.

Functions and Special features

Slim buttons give an easy press action. Pressing the button dims or brightens the light to any level. A quick press switches off. Another press returns the lamp to its previous brightness.

All versions are suitable for dimming most mains dimmable LED lamps and fittings and mains halogen lamps.

Quiet operation.

The soft start feature prolongs the lamp life.

Some LED lamps may require a small resistive load (order code RESLOADE, see page 86) to enable smooth dimming.

Multi-way switching and dimming can be achieved from any position only by using the complementary DANLERS slave switches.

These grid dimmer modules fit any position on the appropriate grid or plate system.

3825

50

front side

Dimmer module for Eurodata plates.Dimmer module for Crabtree grid.

3824

51

front side

34

Dimmer module for MK Grid Plus.

24

59

front side

30

34

58

DIM M I N G

L E D

DIM M I N G

MULTI POIN

T

QUIET

O

P E R ATI O

N

TRAILING EDGE DIMMERS TRAILING EDGE DIMMERS

Quiet grid dimmer modules

Dimensions in mm

59

L

N

load

dimmer

230 VAC DANLERS slave switch

59b. Replace the 2-way switches with a Dimmer and a Slave, as shown

59c. Multi-way switching and dimming (lights can be switched and dimmed from any position)

L

N

load

DANLERS slave switch

DANLERS slave switch

230 VAC

dimmer

* Due to the characteristics and ever changing design of different lamp manufacturers LED drivers DANLERS cannot specify a universal accurate maximum / minimum load. However, use of DANLERS RESLOADE (see page 86) can help to eliminate lamp instability in many LED lamps and fittings. For loading of Grid dimmers on multi-gang plates the following limits also apply:

2 gang plates: Maximum for total plate – 630W

3 or 4 gang plates: Maximum for total plate – 1000W

6, 8, 9 or 12 gang plates: Maximum per row – 1000W

18 or 24 gang plates: Maximum per row – 1200W

Dimensions

Module for MK Grid Plus: 59 x 24 x 34mm, minimum wall box depth of 35mm

Module for Crabtree grid: 51 x 24 x 38mm, minimum wall box depth of 40mm

Module for Eurodata plates: 50 x 25 x 38mm, minimum wall box depth of 35mm

2-wire and intermediate wiring can be used with DANLERS Quiet grid dimmers (see page 63) however all 2-way and intermediate switches must be changed to DANLERS Slave switches SSGS_ _ or SS_SL.

Quiet grid dimmer modules

Order code

Min. and Max. wattage Resistive, mains halogen or dimmable electronic transformer loads

Min. and Max. wattage Dimmable wire-wound or toroidal transformer inductive loads

Min. and Max. wattage LED lamps and fittings*

Wall box depth (mm)

DQDGD MK400W 40 – 400W Not suitable 10 – 200W* 35

DQDGD CB400W 40 – 400W Not suitable 10 – 200W* 40

DQDGD EU400W 40 – 400W Not suitable 10 – 200W* 35

59a. Example of an existing 2-way circuit

N

load230 VAC

L

For MK Grid Plus Order code: DQDGD MK400W

For Crabtree grid Order code: DQDGD CB400W

For Eurodata plates Order code: DQDGD EU400W

SV

SV

TRAILING EDGE DIMMERS TRAILING EDGE DIMMERS

Wiring diagrams

60

DPDLED is compatible with many dimmable LED lamps and fittings.

Ideal to retrofit onto many existing wall plates or can be fitted onto Original Equipment Manufacturers own plates.

Push On / Push OFF, with rotary dimming control.

Can be used in 1-way or 2-way switching circuits.

Thermal fuse for short circuit protection.

Specification

Maximum Load: Maximum load 250W

Minimum Load: Due to the characteristics and ever changing design of different lamp manufacturers LED drivers DANLERS cannot specify a universal accurate minimum load. However, the adjustable spindle on DPDLED can help to eliminate lamp instability in many LED lamps and fittings.

Wiring diagrams: See diagrams 60a, 60b and 60c below.

Dimensions: 25 x 59 x 30mm

LEADING EDGE LED DIMMERS LEADING EDGE LED DIMMERS

Rotary and push LED dimmer module

59

side

25

front

30

Spindle Ø = 6mm

Dimensions in mm

DIM M I N G

L E D

Order code: DPDLED

dimmerL

Nload

230 VAC

60a. 1-way switching and dimming Dimming circuits with 2-way switchingThe lights can be switched on and off and dimmed at the dimmer switch. At the other switch the lights can only be switched on and off at the brightness level which is set by the dimmer switch.

60b. 60c.

Wiring diagrams

L

N

dimmer230 VAC

load

L

N

dimmer230 VAC

load

Adjustable spindle on the back of the product to specify the minimum dim level to help eliminate lamp instability.

61

Push and rotary LED dimmers, 2 way

Suitable for mains dimmable LED lamps and fittings.

Number of gangs Order code Minimum wattage Maximum wattage Wall box

depth (mm)

1 DP1D LED See below* 250W 25mm

2 DP2D LED See below* 250W / gang 25mm

3 DP3D LED See below* 250W / gang 25mm

4 DP4D LED See below* 250W / gang 25mm

* Due to the characteristics and ever changing design of different lamp manufacturers LED drivers DANLERS cannot specify a universal accurate minimum load. However, the adjustable spindle on DPDLED can help to eliminate lamp instability in many LED lamps and fittings.

LEADING EDGE LED DIMMERS LEADING EDGE LED DIMMERS

Square plated dimmer switches(1 gang switch illustrated)

Rectangular plated dimmer switches(4 gang switch illustrated)

front side

12 86

86

front side

12 146

86

Dimensions in mm

Plated push and rotary LED dimmers

DANLERS plated LED dimmer switches (leading edge) are compatible with many dimmable LED lamps and fittings.

Push On / Push OFF, with rotary dimming control.

The range of dimmers includes 1, 2, 3 and 4 gang options in a robust, white polycarbonate moulded plate.

Each dimmer has an adjusted spindle on the back of the product to specify the minimum dim level to help eliminate lamp instability.

Can be used in 1-way or 2-way switching circuits.

Thermal fuse for short circuit protection.

Specification

Material: White polycarbonate

Wiring diagrams: See diagrams 60a, 60b and 60c on page 60.

Dimensions: Square plates: 86 x 86 x 12mm. Minimum wall box depth 25mm.

Rectangular plates: 146 x 86 x 12mm. Minimum wall box depth 25mm.

Order code: DP2D LED

Order code: DP3D LED

Order code: DP4D LED

Order code: DP1D LED

62

These dimmers can be used to dim lights from several locations. They are suitable for dimming resistive lamps, dimmable transformer low voltage lamps.

FunctionsSlim buttons give an easy press action. Pressing the button dims or brightens the light to any level. A quick press switches off. Another press returns the lamp softly to its previous brightness. These dimmers can also be used to control the speed of fans and motors.

Special Features All versions are suitable for mains halogen lamps* without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse.

The soft start feature prolongs the lamp life.

Multi-way switching and dimming can be achieved from any position only by using the complementary DANLERS slave switches (see page 63).

The grid module versions fit any position on the appropriate grid or plate system.

These dimmers automatically switch off in the event of transformer malfunction, helping to protect the dimmer and the transformer.

Dimensions

Square plates: 86 x 86 x 12mm, see table below for wall box depths

Module for MK Grid Plus: 59 x 24 x 34mm, minimum wall box depth of 35mm

Module for Crabtree grid: 51 x 24 x 38mm, minimum wall box depth of 40mm

Module for Eurodata plates: 50 x 25 x 38mm, minimum wall box depth of 35mm

Soft start dimmers

Lights can be switched AND dimmed from several locations.

For loading of Grid dimmers on multi-gang plates the following limits also apply:

2 gang plates: Maximum for total plate – 630W

3 or 4 gang plates: Maximum for total plate – 1000W

6, 8, 9 or 12 gang plates: Maximum per row – 1000W

18 or 24 gang plates: Maximum per row – 1200W

Wiring diagrams: See diagrams 63a - 63d on page 63

Square plated dimmer switches(1 gang switch illustrated)

front side

1286

86

Order code

Min. and Max. wattage Resistive, mains halogen or dimmable electronic transformer loads

Min. and Max. wattage Dimmable wire-wound or toroidal transformer inductive loads

Max. No. of trans-formers

Wall box depth (mm)

DSS1D 250W 40 – 250W 40 – 160W 4 16

DSS1D 400W 60 – 400W 60 – 250W 6 16

DSS2D 250W 40 – 250W /gang 40 – 160W /gang 4/gang 16

DSSGD MK400W 40 – 400W 40 – 250W 6 35

DSSGD CB400W 40 – 400W 40 – 250W 6 40

DSSGD EU400W 40 – 400W 40 – 250W 6 35

DIM M I N G

MULTI POIN

TLEADING EDGE DIMMERS DIMMERS

Dimensions in mm

Order codes: DSS1D 250W, DSS1D 400W

Order codes: DSS2D 250W

For Eurodata plates. Order codes: DSSGD EU400W

For Crabtree grid. Order codes: DSSGD CB400W

For MK Grid Plus. Order codes: DSSGD MK400W

63

63d. Alternative dimming circuits with 2-way switching and dimming

ALTERNATIVE 2-WAy CIRCUIT

63c. Existing alternative 2-way circuit

L

Nload

230 VAC

2-WAy CIRCUIT

63a. Existing 2-way circuit

63f. Dimming circuits with multi-way switching and dimming

INTERMEDIATE CIRCUIT

63e. Existing intermediate circuit

L

N

dimmer

load

230 VAC

L

N load

230 VAC

L

N load

230 VAC

63b. Dimming circuits with 2-way switching and dimming

ALTERNATIVE INTERMEDIATE CIRCUIT

63g. Existing alternative intermediate circuit

63h. Alternative dimming circuits with multi-way switching and dimming

Slave push buttons

These are normally open (push to make) push buttons. They can be used as slave switches to operate a DANLERS Soft start dimmer, as shown in the appropriate wiring diagrams.

SS 1SL is a 1 gang version on a square plate.

SS 2SL is a 2 gang version, with 2 push buttons on a square plate.

These square plated versions both fit into plaster depth (16mm) wall boxes. Dimensions as below.

Also available as grid modules (for dimensions see below):

SSGS MK for MK Grid Plus. Minimum wall box depth 35mm.

SSGS CB for Crabtree grid. Minimum wall box depth 40mm.

SSGS EU for Eurodata plates. Minimum wall box depth 35mm.

L

Nload

dimmer230 VAC

L

S

L

S

VL

S

L

S

VL

S

L

Nload

dimmer

230 VAC

LS

V

S

DANLERS slave

switch

L

Nload

230 VAC

L

N

dimmer

load

230 VACDANLERS slave switch

DANLERS slave switch

L

VS

L L

S S

SL

SL

slave

SL

slave slave

SL

LEADING EDGE DIMMERS DIMMERS

Wiring diagrams - Quiet dimmers and Soft start dimmers (plated and grid)

64

A range of dimmers with elegant styling. Dim lights to any brightness.

Versions are available for tungsten loads and dimmable low voltage transformer loads. All versions are suitable for mains halogen lamps* without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse.

Specification

Material: White polycarbonate

Rotary dimmers: Rotary on/off switching, rotary dimming control. 1 way only

Push dimmers: Push on, push off, with rotary dimming control. 1 or 2 way switching

Wiring diagrams: See diagram 64a below for rotary dimmers

Wiring diagrams: See diagram 64b, 64c, 64d and 64e below for push on, push off dimmers with rotary dimming control

Dimensions: Square plates: 86 x 86 x 12mm, see below See tables on page 59 for wall box depths

Rectangular plates: 146 x 86 x 12mm, see below See tables on page 65 for wall box depths

Square plated dimmer switches(1 gang switch illustrated)

Rectangular plated dimmer switches(4 gang switch illustrated)

front side

1286

86

front side

12146

86

LEADING EDGE DIMMERS LEADING EDGE DIMMERS

Rotary and push dimmers

dimmerL

Nload

230 VAC

64a. 1-way switching and dimming

Dimensions in mm

64b. Intermediate circuit

L

N

dimmer

230 VAC

load

64c. Intermediate circuit (alternative)

L

N

dimmer

230 VAC

load

Dimming circuits with 2-way switchingThe lights can be switched on and off and dimmed at the dimmer switch. At the other switch the lights can only be switched on and off at the brightness level which is set by the dimmer switch.

64d. 64e.

L

N

dimmer230 VAC

load

L

N

dimmer230 VAC

load

Wiring diagrams

65

Tungsten rotary dimmers, 1 way

Suitable for resistive loads. Suitable for mains halogen lamps* without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse.

Number of gangs Order code Min. and Max. wattage Max. No. of

transformersWall box depth (mm)

1 DR1D 250W 40 – 250W - 16

1 DR1D 400W 60 – 400W - 16

2 DR2D 250W 40 – 250W/gang - 16

Low voltage push dimmers, 2 way

For dimmable electronic transformer loads.

1 DP1D 250WIET 40 – 250W 4 16

1 DP1D 400WIET 60 – 400W 6 16

1 DP1D 630WIET 60 – 630W 8 40

1 DP1D 1000WIET 60 – 1000W 12 25

2 DP2D 250WIET 40 – 250W/gang 4/gang 16

3 DP3D 250WIET 40 – 250W/gang 4/gang 16

4 DP4D 250WIET 40 – 250W/gang 4/gang 16

Low voltage push dimmers, 2 way

For dimmable wire-wound transformer inductive loads.

1 DP1D 250WI 60 – 250W 6 16

1 DP1D 400WI 60 – 400W 8 40

1 DP1D 630WI 60 – 630W 12 25

2 DP2D 160WI 40 – 160W/gang 4/gang 16

Tungsten push dimmers, 2 way

Suitable for resistive loads. Suitable for mains halogen lamps* without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse.

1 DP1D 250W 40 – 250W - 16

1 DP1D 400W 60 – 400W - 16

1 DP1D 630W 60 – 630W - 40

1 DP1D 1000W 100 – 1000W - 25

2 DP2D 250W 40 – 250W/gang - 16

3 DP3D 250W 40 – 250W/gang - 16

4 DP4D 250W 40 – 250W/gang - 16

Push switch, 2 way

On/off switch to match Rotary and push dimmer range. 1 or 2 way switching.

1 DP1S 1500W 0 - 1500W N/A 16

LEADING EDGE DIMMERS LEADING EDGE DIMMERS

Rotary and push dimmers

66

Order codes: DP1D 10VDC SB DP1D 10VDC MB DP1D DSI

Push on, push-off, with rotary dimming control.

Specification

DP1D 10VDC SB: For one or two dimmable ballasts with 1-10VDC input (including LEDs)

Wiring diagram: See diagram 66a below

Loading: Total load of ballast, lamps plus other load not more than 6 amps including fluorescent.

Dimensions: 86 x 86 x 12mm. Wall box depth 16mm

DP1D 10VDC MB: For multiple dimmable ballasts with 1-10VDC input (including LEDs)

Wiring diagram: See diagram 66b below

Loading: Total load of ballast, lamps plus other load not more than 6 amps including fluorescent. Can control up to 20mA, eg. 20 ballasts at 1mA. (Control current of ballast is usually specified at 1-10V terminals.)

Dimensions: 86 x 86 x 12mm. Wall box depth 16mm

DP1D DSI: For multiple DSI dimmable ballasts

Wiring diagram: See diagram 66c below

Loading: Total load of ballast, lamps plus other load not more than 6 amps including fluorescent. Can control up to 20 DSI ballasts

Dimensions: 86 x 86 x 12mm. Wall box depth 35mm.

High frequency controllers (plated)

66c. DP1D DSI dimming several DSI ballasts (optional multi-way switching illustrated)

66b. DP1D 10VDC MB dimming several 1-10VDC ballasts (optional multi-way switching illustrated)

DP1D 10VDC MB

1ballast

10

1ballast

10

1ballast

10

control lines

L

230 VAC

Optional 2-way switch

Optional intermediate switch(es)

L1

L2

N

SL

optional other load*

* Total load of ballasts, lamps plus other load not more than 6 amps

DP1D DSI

D1ballast

D2

D1ballast

D2

D1ballast

D2

control lines

L

230 VAC

Optional 2-way switch

Optional intermediate switch(es)

L1

L2

N

SL

optional other load*

* Total load of ballasts, lamps plus other load not more than 6 amps

MANUAL HIGH FREQUENCY DIMMERS MANUAL HIGH FREQUENCY DIMMERS

front side

12 86

86

DP1D 10VDC SB, DP1D 10VDC MB, DP1D DSI

66a. DP1D 10VDC SB dimming a single 1-10VDC ballast (optional multi-way switching illustrated)

DP1D 10VDC SB

control lines

1ballast

10L

Optional 2-way switch

Optional intermediate switch(es)

N

L1

L2

230 VAC

SL

optional other load*

* Total load of ballast(s), lamps plus other load not more than 6 amps

Dimensions (in mm) Wiring diagrams

67

Suitable for dimmable ballasts with 1-10VDC input (including LEDs). Push on, push off, hold to dim. Versions to suit the MK Grid Plus, Crabtree grid and Eurodata plates.

They may be placed in any position on the appropriate grid or plate.

They can also be operated by additional mains rated, normally open retractive switches. Please call for details.

Specification

Wiring diagram: See diagram 67 below

Loading: Total load of ballast, lamps plus other load not more than 6 amps including fluorescent. Can control up to 20mA, eg. 20 ballasts at 1mA. When controlling LED drivers a load capacitor (order code CAPLOAD) may be required to augment the load

Dimensions: Module for MK Grid Plus: 59 x 24 x 34mm. Minimum wall box depth 35mm

Module for Crabtree grid: 51 x 24 x 38mm. Minimum wall box depth 40mm

Module for Eurodata plates: 50 x 25 x 38mm. Minimum wall box depth 35mm

High frequency controllers (grid modules)

67. DSSGD MK 10VDC, DSSGD CB 10VDC, DSSGD EU 10VDC dimming several 1-10VDC ballasts

* Total load of ballasts, lamps plus other load not more than 6 amps

1ballast

10

1ballast

10

1ballast

10

control lines

L

230 VAC

Optional mains rated,

normally open push button(s)

LN

N

High frequency grid dimmer module

SL

optional other load*

R

For MK Grid Plus Order code: DSSGD MK 10VDC

For Crabtree grid Order code: DSSGD CB 10VDC

For Eurodata plates Order code: DSSGD EU 10VDC

MANUAL HIGH FREQUENCY DIMMERS MANUAL HIGH FREQUENCY DIMMERS

DSSGD MK 10VDCRequires wall box depth of 35mm

24

59

front side

30

34

DSSGD CB 10VDCRequires wall box depth of 40mm

3824

51

front side

34

DSSGD EU 10VDCRequires wall box depth of 35mm

3825

50

front side

Dimensions (in mm) and wiring diagrams

Wiring diagram