Extremely Low Leak Rate <0.005 sccm for FS Flow Rates 5 sccm -150 slpm <15.6 sccm for FS Flow Rates >150 slpm An enhanced control valve eliminates the need for a separate shut-off valve in the gas delivery system. One less system component reduces design, testing and validation time, and system footprint. TRADITIONAL MFC: Shut-off Valve Required SLA Biotech MFC: Simplified Gas Delivery System MFC Shut-off Valve No Shut-off Valve Needed MFC Bioreactor Bioreactor TRADITIONAL MFC: Low-Flow & High-Flow MFCs Required SLA Biotech MFC: Simplified Gas Box Configuration High- Flow MFC Low- Flow MFC Bioreactor High Turn- Down MFC Bioreactor Low- Flow MFC Thermal Mass Flow Controllers & Meters BrooksInstrument.com/BiotechMFC Profibus®, PROFINET, RS-485

Upload: others

Post on 23-Aug-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TRADITIONAL MFC: Low-Flow & High-Flow MFCs Required/media/brooks... · 2020. 1. 8. · TRADITIONAL MFC: Low-Flow & High-Flow MFCs Required SLA Biotech MFC: Simpli˜ed Gas Box Con˜guration

Extremely Low Leak Rate• <0.005 sccm for FS Flow Rates 5 sccm -150 slpm• <15.6 sccm for FS Flow Rates >150 slpm• An enhanced control valve eliminates the need for a

separate shut-off valve in the gas delivery system.• One less system component reduces design, testing

and validation time, and system footprint.

TRADITIONAL MFC: Shut-o� Valve Required

SLA Biotech MFC: Simpli�ed Gas Delivery System

MFC

Shut-o� Valve

NoShut-o�

ValveNeeded

MFC

Bioreactor

Bioreactor

TRADITIONAL MFC: Low-Flow & High-Flow MFCs Required

SLA Biotech MFC: Simpli�ed Gas Box Con�guration

High-FlowMFC

Low-FlowMFC

Bioreactor

HighTurn-DownMFC

Bioreactor

Low-FlowMFC

Thermal Mass Flow Controllers & Meters

BrooksInstrument.com/BiotechMFC

Profibus®, PROFINET, RS-485

Page 2: TRADITIONAL MFC: Low-Flow & High-Flow MFCs Required/media/brooks... · 2020. 1. 8. · TRADITIONAL MFC: Low-Flow & High-Flow MFCs Required SLA Biotech MFC: Simpli˜ed Gas Box Con˜guration

• When combined with a high turndown ratio, the SLA Series Biotech can be field-configured, reducing the number of MFC configurations required by up to 90%.

• Air, CO2, N2 & O2 flows can be changed insitu to reduce the variety of MFC spares kept in stock.

TRADITIONAL MFC: Each MFC – Unique Con�guration for Every Gas & Range

SLA Biotech MFC: Each MFC – Same Con�guration with Wide Turndown & Multi-Gas

MFCN2

MFCO2

MFCCO2

Bioreactor

Bioreactor

MFCAir

Optional Premium Materials & Certificates

SLABiotech-1/20 © Copyright 2020 Brooks Instrument, LLC All rights reserved.

Pre-calibrated Multi-gas Pages

USP, FDA, ADI-free Class VI O-rings & Valve Seats

*Certificate Included

Class VI Elastomers

• Materials of Construction (wetted path)• 2.2 Material Cert• NIST/ICC Calibration Traceability

Certifications

SLA5800 & SLAMf Series

Standard

SLA5800 & SLAMf Series

BiotechPerformance

SLA5800 & SLAMf Series

Biotech Premium

Zero Stability ±0.20% FS per year

Accuracy ±0.9% of SP (20-100% FS)

Repeatability 0.20% SP

Advanced DiagnosticsEnsures device is operating within user speci�edlimits for high process yield uptime.

Analog & Digital I/ODeviceNet , EtherCAT , EtherNet/IP FOUNDATIONRS-485

High Turndown Ratio

Extremely Low Leak Rate Valve

• 0.005 sccm for < 150 slpm • 15.6 sccm for > 150 slpm

Enhanced Sensor Design Meets industry standards for cleanliness

Pre-calibrated

Multi-gas PagesAir, CO2, N2, O gas pages can be changed in 2

Class VI Elastomers

USP, FDA, ADI-free Class VI O-rings & ValveSeats

Materials of construction (wetted path)• 2.2 Certi�cations• NIST/ICC Calibration Traceability

Fieldbus, Pro�bus, PROFINET,

• 250:1 FS �ow rates 5 sccm -150 slpm• 150:1 all other FS �ow rates

situ to reduce the variety of spare instrumentsstocked

Options PackagesPerformance Package• Includes enhancements reducing cost of

operationPremium Package• Performance Package features plus: • Premium materials and associated certificates