Sds-max.com.ua Installation instructions for TOYOTA 2.0, 2.2 and 2.5, 3.0, 4.0, 4,5 (later) TOYOTA 2.0, 2.2 Correct and error-free operation of the particulate filter emulator is guaranteed only in case of properly functioning flow meter and properly functioning 1 st temperature sensor of the particulate filter. Place the emulator interior or under hood. Keep the emulator away from water. Connection: In Toyota/Lexus the yellow wire is connected to signal wire of the flow meter. The voltage of signal wire should change with change of engine speed: in the Flow meter No. 22204-27010 to the leg No. 1 (old engine 2.0 D4D D-CAT) in the Flow meter No. 22204-0N010 to the leg No. 3 (new engine 2.0 D4D D-CAT or 2.2 D- CAT) If after installation the error P2002 appears, connect the ends of the sensor No. 2 to the sensor No. 1 (turn them on in parallel). In order the emulator to operate properly, the temperature sensors should be in the exhaust stream, but not away from it. Usually they use native case of the particulate filter. It is not necessary to remove the catalyst.

Upload: trinhlien

Post on 29-Apr-2018

413 views

Category:

Documents


21 download

TRANSCRIPT

Page 1: TOYOTA 2.0, 2 Unit switching transistors MAF ... FTV, 2KD-FTV, 1VD-FTV) ... The yellow wire is connected to pin MAF №5

Sds-max.com.ua

Installation instructions for TOYOTA 2.0, 2.2 and 2.5, 3.0, 4.0, 4,5 (later) TOYOTA 2.0, 2.2

Correct and error-free operation of the particulate filter emulator is guaranteed only in case of properly functioning flow meter and properly functioning 1st temperature sensor of the particulate filter.

Place the emulator interior or under hood. Keep the emulator away from water. Connection:

In Toyota/Lexus the yellow wire is connected to signal wire of the flow meter. The voltage of

signal wire should change with change of engine speed: in the Flow meter No. 22204-27010 to the leg No. 1 (old engine 2.0 D4D D-CAT) in the Flow meter No. 22204-0N010 to the leg No. 3 (new engine 2.0 D4D D-CAT or 2.2 D-

CAT) If after installation the error P2002 appears, connect the ends of the sensor No. 2 to the sensor No.

1 (turn them on in parallel). In order the emulator to operate properly, the temperature sensors should be in the exhaust

stream, but not away from it. Usually they use native case of the particulate filter. It is not necessary to remove the catalyst.

Page 2: TOYOTA 2.0, 2 Unit switching transistors MAF ... FTV, 2KD-FTV, 1VD-FTV) ... The yellow wire is connected to pin MAF №5

Sds-max.com.ua

Additional nozzle

There is additional nozzle in Toyota D-CAT and D4D that operates during filter regeneration. It is necessary to disconnect this nozzle and instead of the 5th nozzle to connect the resistance of 5W 10 – 20 Om.

ECU

Unit switching transistors

MAF

Differential pressure sensor

OBD

Temperature sensor 1

Temperature sensor 2

Page 3: TOYOTA 2.0, 2 Unit switching transistors MAF ... FTV, 2KD-FTV, 1VD-FTV) ... The yellow wire is connected to pin MAF №5

Sds-max.com.ua

Adjustment

After installation of the emulator, it is necessary to eliminate all errors. After elimination of the errors perform the trial run.

During run along the route the temperature should not be more than 650 degrees. In case of noncompliance, please contact the supplier.

Fuel temperature sensor

Coolant temperature sensor

Fuel injector in an exhaust system

Page 4: TOYOTA 2.0, 2 Unit switching transistors MAF ... FTV, 2KD-FTV, 1VD-FTV) ... The yellow wire is connected to pin MAF №5

Sds-max.com.ua

Installation instructions for TOYOTA D4-D 2.5, 3.0, 4.0, 4,5 (Engines 1KD-FTV, 2KD-FTV, 1VD-FTV)

Correct and error-free operation of the particulate filter emulator is guaranteed only in case of properly functioning flow meter and properly functioning 1st temperature sensor of the particulate filter.

Place the emulator interior or under hood. Keep the emulator away from water.

Connection:

The yellow wire is connected to pin MAF №5. (Voltage on pin of about 2,5 volts) In order the emulator to operate properly, the temperature sensors should be in the exhaust

stream, but not away from it. Usually they use native case of the particulate filter. It is not necessary to remove the catalyst.

Additional nozzle There is additional nozzle in Toyota D4D that operates during filter regeneration. It is necessary to

disconnect this nozzle and instead of the 5th nozzle to connect the resistance of 5W 10 – 20 Om.

3 1

Page 5: TOYOTA 2.0, 2 Unit switching transistors MAF ... FTV, 2KD-FTV, 1VD-FTV) ... The yellow wire is connected to pin MAF №5

Sds-max.com.ua

1. ECU 4. Exhaust fuel addition injector 5, 6. Exhaust gas temperature sensor (emulator does not connect) 8. Exhaust gas temperature sensor №1 10. Oxygen sensor (emulator does not connect) 11. Exhaust gas temperature sensor №2 28. MAF

Page 6: TOYOTA 2.0, 2 Unit switching transistors MAF ... FTV, 2KD-FTV, 1VD-FTV) ... The yellow wire is connected to pin MAF №5

Sds-max.com.ua

Adjustment

After installation of the emulator, it is necessary to eliminate all errors. After elimination of the errors perform the trial run.

During run along the route the temperature should not be more than 650 degrees. In case of noncompliance, please contact the supplier.

Page 7: TOYOTA 2.0, 2 Unit switching transistors MAF ... FTV, 2KD-FTV, 1VD-FTV) ... The yellow wire is connected to pin MAF №5

Sds-max.com.ua

Connecting for Toyota 4,5l