tower counter top stg rf - cossiga · stg accessories top mounted controller panel price tabs 450...
TRANSCRIPT
Download C.A.D models or contact us on COSSIGA.COMPage 1
TOWER COUNTER TOP STG
STG RF6STG RF9STG RF12STG RF15
STG HT6STG HT9STG HT12
RFDeck forced refrigerationSliding doors front and rearDouble glazedTwo adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsIntegral condensorSelf evaporatingSolid glass front - optionalSTG RF6 hinged rear door
HTSliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalSTG HT6 hinged rear door
Download C.A.D models or contact us on COSSIGA.COMPage 2
AB
BM
Sliding doors front and rearSingle glazedThree adjustable shelvesTicket strips on shelves and deckUndershelf and canopy LED lightsSolid glass front - optionalAmbient converted from heatedAir removal fan installed in ceilingSTG AB6 hinged rear door
Sliding doors front and rearOverhead halogen lightsWet / dry element in baseSingle glazed glassSolid glass front - optional
STG AB6STG AB9STG AB12
STG BM6STG BM9STG BM12
TOWER COUNTER TOP STG
Download C.A.D models or contact us on COSSIGA.COMPage 3
OHOpen front heatedSingle glazedIndividual shelf heating including baseTicket strips on shelves and baseUndershelf and canopy LED lights
STG OH6STG OH9
351
TOWER COUNTER TOP STG
Download C.A.D models or contact us on COSSIGA.COMPage 4
CABINET DIMENSIONS & SPECIFICATIONSMODEL CABINET SHELVING REFRIGERANT TOTAL
FOODOPERATING CURRENT
CONNECTION VOLTAGE PACKED FOR SHIPPING
LENGTH [MM]
DEPTH[MM]
HEIGHT[MM]
CUTOUTS
NO. SIZE W X D 100MMUNITS
LENGTH [MM]
DEPTH[MM]
HEIGHT[MM]
WEIGHT[KG]
CUBE
STGRF6 600 650 925 615x620 2+BASE 490 X 395 134A 55 4.3AMP 10 AMP 3 PIN PLUG 220~240V 700 730 1400 143 0.72
STGRF9 900 650 925 915x620 2+BASE 790 X 395 134A 84 4.5AMP 10 AMP 3 PIN PLUG 220~240V 1000 730 1450 178 1.06
STGRF12 1200 650 925 1215x620 2+BASE 1090 X 395 134A 121 5.0AMP 10 AMP 3 PIN PLUG 220~240V 1300 730 1450 212 1.38
STGRF15 1500 650 925 1515x620 2+BASE 1390 x 395 134a 154 5.2AMP 10 AMP 3 PIN PLUG 220~240V 1600 730 1450 243 1.69
STGHT6 600 650 925 615x620 3+BASE 490 x 395 55 4.6AMP 10 AMP 3 PIN PLUG 220~240V 700 730 1100 88 0.56
STGHT9 900 650 925 915x620 3+BASE 790 x 395 84 6.2AMP 10 AMP 3 PIN PLUG 220~240V 1000 730 1100 110 0.80
STGHT12 1200 650 925 1215x620 3+BASE 1090 x 395 121 8.3AMP 10 AMP 3 PIN PLUG 220~240V 1300 730 1100 126 1.04
STGAB6 600 650 925 615x620 3+BASE 490 x 395 55 0.2AMP 10 AMP 3 PIN PLUG 220~240V 700 730 1100 77 0.56
STGAB9 900 650 925 915x620 3+BASE 790 x 395 84 0.3AMP 10 AMP 3 PIN PLUG 220~240V 1000 730 1100 97 0.80
STGAB12 1200 650 925 1215x620 3+BASE 1090 x 395 121 0.4AMP 10 AMP 3 PIN PLUG 220~240V 1300 730 1100 110 1.04
STGBM9 900 650 925 915x620 9.9AMP 15 AMP SUPPLY LEAD ONLY 220~240V 1000 730 1100 99 0.80
STGBM12 1200 650 925 1215x620 11.0AMP 15 AMP SUPPLY LEAD ONLY 220~240V 1300 730 1100 119 1.04
STGBM15 1500 650 925 1515x620 15.0AMP 20 AMP SUPPLY LEAD ONLY 220~240V 1600 730 1100 140 1.28
STGOH6 600 650 925 615x620 2+BASE1. 490 x 3472. 490 x 427B. 548 x 495
18 8.1 AMP 10 AMP 3 PIN PLUG 220~240V 700 730 1400 95 0.72
STGOH9 900 650 925 915x620 2+BASE1. 790 x 3472. 790 x 427B. 848 x 495
41 9.1 AMP 10 AMP 3 PIN PLUG 220~240V 1000 730 1450 120 1.06
TOWER STG
Download C.A.D models or contact us on COSSIGA.COMPage 5
STG RF6
STG RF6 STG RF9
STG RF12 STG RF15
STG RF9STG RF12STG RF15
TOWER STG RF
Download C.A.D models or contact us on COSSIGA.COMPage 6
TOWER STG HT STG AB
STG HT6 STG AB6
STG HT9 STG AB9
STG HT12 STG AB12
Download C.A.D models or contact us on COSSIGA.COMPage 7
TOWER STG BM
Download C.A.D models or contact us on COSSIGA.COMPage 8
TOWER STG OH
STGOH6 STGOH6
Download C.A.D models or contact us on COSSIGA.COMPage 9
REMOTE INSTALLATION AND SERVICES
Units are self evaporating to a receptacle in the condensor unitn areas of high humidity units should be plumbed directly to a waste.
Plumbed Receptacle
Maximum 150 mm above finished floor level
Drainage to building waste
Building waste by client
Receptacle placed under unit
3/8” pipe max run 1500 mm
condensate drainto four litre container
Vertical pipe runs are not recommended
Pipe runs over 150mm : Expansion valve will need to be fitted Correctly sized condensing unit fitted Correct pipe size determined
Download C.A.D models or contact us on COSSIGA.COMPage 10
JOINERY AIR FLOW CONSIDERATIONS
350 mm
260
mm
varies
vari
es
Hole Cut to meet condenser face
Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face
Joinery divider panelproviding sealed air intakeplenum with cutout to meetcondenser face
200mm clear space
Intake and extract vents.Min 400mm x 400mm openarea
Closed rear front vented Closed front rear vented
Download C.A.D models or contact us on COSSIGA.COMPage 11
EXTRACTION FAN
Extract hot air from box joinery
Fan and power cable supplied, screw fixed to joinery
Electrical power cord 2000mm 3 pin 10 amp 1 phase socket required
Fan 230v ~ 50Hz - 60Hz - 19 Watt in stainless steel case
EXTRACTION FAN
150 mm
Cut out see table
Cut out 585 mm
Cut out 620 mmmin 20 mm
min 20 mm
Cut out 525 mmmin 75 mm
min 75 mm
Condensor unit545w x 485d x 390h(RF6 485w x 485d x 335h)
Condensor unit545w x 485d x 390h(RF6 485w x 485d x 335h)
RF6 Cut out 525 mmRF6 Cut out 525 mm
ALLO
W 4
00 m
m
ALLO
W 4
00 m
m
Open at rear. Open at rear.
Supplied 5mm PVCwedge strip to sidesfor drop-in unit.
Remove feet for alldrop-in installations
Download C.A.D models or contact us on COSSIGA.COMPage 12
DROP IN COUNTER TOP CUT OUT DETAILS
Supplied 5mm PVCwedge strip to sidesfor drop-in unit.No glue or sealant required
Full bench top drop in On bench top drop in
benchtop cut out sizes
Download C.A.D models or contact us on COSSIGA.COMPage 13
JOINERY TO REAR WALL WITH VENT
Horizontal vent in cabinet top for hot air extract
Electric biscuit fans can also be fitted to provide mechanical extract
Ambient air ducted in to compressor face through air plenum space
Joinery divider panel providing sealed air intake plenum with cut out to meet condensor face
Allow access for cleaning, servicing and waste evaporator water removal
Ambient air is drawn into front vented area Hot air must escape joinery cabinet A horizontal vent should be used behind the unit
Vent must be at least 100mm deep and as wide as unit
Download C.A.D models or contact us on COSSIGA.COMPage 14
AIRFLOW AND PLACEMENT GUIDE LINES
Blocked air flow will retard operation on both HOT and COLD units
Ensure trays or plates are not blocking air flow at rear
CORRECT AIR FLOW INCORRECT AIR FLOW
CLEAR FLOW
NO AIR FLOW
AIR FLOW BLOCKED
too much chilled airaround coil can createexcessive ice build up
Heat from other equipment and natural conditions can cause cooling failures and overheating of compressors
Locations to avoid are :Close to shop front exterior In an outside location In direct sunlightIn a high cross wind areaNear any source producing excessive heatService units more frequently in dusty or polluted areas
Download C.A.D models or contact us on COSSIGA.COMPage 15
Ventilation Grill
STG ACCESSORIES
Top Mounted Controller Panel
Price Tabs
450
mm
450 mm
Base Tray - Heated Units
Tong Holder
Bag Holder
Humidity Dish
100 mm
190 mm
80 mm
180
mm
220 mm
190 mm
105 mm
75 mm
For against wall installationsSold individually
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelSold individually
Stainless SteelDrop into counter tray raceSolid individually
Stainless SteelDrop into counter tray raceSold individually
Stainless SteelFor heated unitsSold in pairs
Stainless SteelPerforated lid is removable
Download C.A.D models or contact us on COSSIGA.COMPage 16
Price TabsLengths
Ticket Strip
Stainless SteelWrite on with marker or adhesive tapeMeasure 60mm x 30mmSold in packs of 20
Stainless SteelFits over front of shelves
CABINETLENGTH MM
TICKET STRIP LENGTH
600 475
900 775
1200 1075
1500 1375
End Profile
TICKET STRIP
Download C.A.D models or contact us on COSSIGA.COMPage 17
Applied to the inside glass rear doors
Suitable for heated and chilledunits
Mirror film adhered to inside of rear door glass
Mirror film adhered to inside of rear door glass
FREE STANDING UNITS BENCHTOP UNITS
Blocks work areasbehind units
Add depth toyour displays
MIRROR FILM
Download C.A.D models or contact us on COSSIGA.COMPage 18
Pie Trays
Stainless Steel ConstructionPlaced on shelves for heated food items
PIE TRAYS PIE TRAYS
MODEL CODE QUANTITY 1ST SHELFDEPTH
2ND SHELFDEPTH
3RD SHELFDEPTH
TOTAL TRAYWIDTH
STGHT6 AA16015 4 Per Shelf 400MM 365MM 400MM 12 Trays 120MM
STGHT9 AA16016 6 Per Shelf 400MM 400MM 400MM 18 Trays 130MM
STGHT12 AA16017 9 Per Shelf 400MM 400MM 400MM 27 Trays 120MM
Gastro Norm System
Stainless Steel ConstructionAngled display view
GASTRO NORM
MODEL CODE QUANTITY DIMENSIONS PAN DEPTH
STGHT6 F92-315 2 Per Unit 265MM X 325MM PANS AND FRAME 65MM
STGHT9 F92-316 3 Per Unit 265MM X 325MM PANS AND FRAME 65MM
STGHT12 F92-317 4 Per Unit 265MM X 325MM PANS AND FRAME 65MM
STG HEATED UNIT ACCESSORIES
Download C.A.D models or contact us on COSSIGA.COMPage 19
STG GLASS SHELVINGGlass Shelf OptionsStandard wire racks are removed and replaced with 6mm toughened glass panes
Support bracket
MODEL GLASS WIDTHMM
DEPTHMM
PER SHELFPANES
SHELVES TOTAL PANES
STGRF6 6MM TOUGHENED - POLISHED EDGES 240 385 2 2 4
STGRF9 6MM TOUGHENED - POLISHED EDGES 390 385 2 2 4
STGRF12 6MM TOUGHENED - POLISHED EDGES 540 385 2 2 4
STGRF15 6MM TOUGHENED - POLISHED EDGES 690 385 2 2 4
STGHT6 6MM TOUGHENED - POLISHED EDGES 240 385 2 3 6
STGHT9 6MM T(OUGHENED - POLISHED EDGES 390 385 2 3 6
STGHT12 6MM TOUGHENED - POLISHED EDGES 540 385 2 3 6
STGAB6 6MM TOUGHENED - POLISHED EDGES 240 385 2 3 6
STGAB9 6MM TOUGHENED - POLISHED EDGES 390 385 2 3 6
STGAB12 6MM TOUGHENED - POLISHED EDGES 540 385 2 3 6
Maximum shelf load weight 15kg spread evenly