towel rails brochure
DESCRIPTION
Nu-Heat towel rails brochureTRANSCRIPT
wa r m wat e r u n d e r f l o o r h e at i n g
design innovation expertise service
Nu-HeatU N D E R F L O O R & R E N E W A B L E S
towel rails
11.11.09V8
towel rails
To complement the Nu-Heat underfloor heating systemand EnergyMaster™ cylinder package, Nu-Heat introducesits stunning new contemporary range of 100% stainlesssteel heated towel rails.
Nu-Heat always recommends that heated towel rails are used in addition to warm water underfloor heating – they give the luxury ofwarm dry towels all year round and add extra warmth and comfortto bathrooms.
Nu-Heat towel rails are manufactured in stainless steel as this hassignificant advantages over traditional chrome rails which cannot beused on a domestic water circuit. It will not rust or flake, is easy toclean and totally hygienic. All towel rails are produced from over90% recycled, 304 grade metal, are manufactured environmentallyand are themselves 100% recyclable. Small marks or scratches canbe polished out to maintain high surface quality over many years.Each towel rail is manufactured with standard 1/2“ BSP tappings andis pressure tested to 12 Bar.
We have such confidence in the high standard of manufacture thatNu-Heat towel rails are guaranteed for 25 years.
Towel rails can be installed directly off the boiler; alternatively, oneof the most successful installation methods is to fit it directly onto anAquastar™ hot water loop. Aquastar™ is a small bronze pump withbuilt-in timer that circulates warm water from the cylinder under thedomestic hot water draw off points. As soon as the tap is opened,instant domestic hot water is provided, no matter the distance fromthe cylinder. Towel rails are simply plumbed into this circuit meaningthat they can work independently of the heating – particularly useful in the summer. In addition, towel rails on this circuit are atdomestic hot water temperature rather than full boiler temperaturepreventing any risk of scalding. All models can, of course, be fitteddirectly onto a standard radiator circuit.
Please refer to the Nu-Heat website for more details on both the EnergyMaster™ mains pressure hot water cylinder andAquastar™ hot water loop.
benefits of nu-heat towel rails
• Guaranteed for 25 years against manufacturing defects
• Stunning contemporary range of options to choose from
• Made from 100% polished stainless steel
• Made from over 90% recycled 304 grade metal
• Easy to keep clean and highly polished
• Warm, dry towels all year round
• Can be installed on the Aquastar™ pumped domestic hot water loop
guarantee
A 25 year guarantee against manufacturing defects for all towel railsand radiators, proof of purchase is required for a replacement unit;guarantee does not extend to fitting costs and delivery charges.
See the full range of towel rails at www.towelrails.co.uk or telephone 0800 731 1976.
Radiator lockshield
valves
Outlet balancingvalves
Pump
Flush/drain
ExpansionVessel
Discharge
Loop balancingvalves
Non-returnvalve
(may bepart ofpump)
For cylinder connectiondetails refer to cylindermanufacturer
planning and installing the loop
Bathroom 1
Bathroom 3 Kitchen Utility
Bathroom 2
out
return
flat fronted rails www.towelrails.co.uk
Farway 620 Farway 520
Musbury 620 Musbury 520
Farway 400
Musbury 400
Farway 300 (Not illustrated) TRF300P-C1250x300mm 2103btu/617watts
Farway 400 TRF400P-C1250x400mm 2368btu/694watts
Farway 520 TRF520P-C1250x520mm 2500btu/733watts
Farway 620 TRF620P-C1250x620mm 2726btu/799watts
Musbury 300 (Not illustrated) TRM300P-C700x300mm 1068btu/313watts
Musbury 400 TRM400P-C700x400mm 1380btu/404watts
Musbury 520 TRM520P-C700x520mm 1500btu/440watts
Musbury 620 TRM620P-C700x620mm 1648btu/483watts
www.towelrails.co.uk
Uplyme 620 Uplyme 520 Uplyme 400
curved fronted rails
Kilmington 620 Kilmington 520 Kilmington 400
Uplyme 400 TRU400P-C1250x400mm 2486btu/728watts
Uplyme 520 TRU520P-C1250x520mm 2600btu/762watts
Uplyme 620 TRU620P-C1250x620mm 2841btu/832watts
Kilmington 400 TRK400P-C700x400mm 1449btu/425watts
Kilmington 520 TRK520P-C700x520mm 1600btu/469watts
Kilmington 620 TRK620P-C700x620mm 1763btu/517watts
flat fronted rails
Colyford Bickleigh 1000
Cotleigh Oakford Dolton
www.towelrails.co.uk
Colyford TRC600P-C1191x600mm 2859btu/838watts
Bickleigh 750 (Not illustrated) TRB750P-C600x750mm 1676btu/491watts
Bickleigh 1000 TRB1000P-C600x1000mm 1885btu/552watts
Cotleigh TRCT500P-C780x500mm 1998btu/585watts
Oakford TRO520P-C700x520mm 740btu/217watts
Dolton TRD520P-C370x520mm 410btu/120watts
stainless steel feature radiators with towel hanger options
Woodbury with towel hanger
Woodbury Salston with towel hanger Salston
www.towelrails.co.uk
Woodbury 1460/360 TRW14/360P-C1460x360mm 2406btu/705watts
Woodbury 1460/530 TRW14/530P-C1460x530mm 2785btu/816watts
Woodbury 1460/710 TRW14/710P-C1460x710mm 3498btu/1025watts
Woodbury 1660/360 TRW16/360P-C1660x360mm 2944btu/862watts
Woodbury 1660/530 TRW16/530P-C1660x530mm 3408btu/998watts
Towel hanger for Woodbury 360mm TRHW360P-C530mm TRHW530P-C710mm TRHW710P-C
Salston 1460/275 (3 panels) Satin finish TRS14/3S-C1460x275mm 2154btu/631watts
Salston 1460/360 (4 panels) Satin finish TRS14/4S-C1460x360mm 2839btu/832watts
Salston 1460/535 (6 panels) Satin finish TRS14/6S-C1460x535mm 3676btu/1077watts
Salston 1960/275 (3 panels) Satin finish TRS19/3S-C1960x275mm 2805btu/822watts
Salston 1960/360 (4 panels) Satin finish TRS19/4S-C1960x360mm 3715btu/1088watts
Salston 1960/535 (6 panels) Satin finish TRS19/6S-C1960x535mm 4210btu/1233watts
Towel hanger for Salston Satin finish3 panel TRHS3S-C4 panel TRHS4S-C6 panel TRHS6S-C
towel rail spec & dimensions www.towelrails.co.uk
* Heat output for installation directly from boiler – based on ΔT=60˚C (i.e. 80˚C flow temperature, 20˚C room temperature).** Heat output for installation on Secondary Hot Water Loop – based on ΔT=35˚C (i.e. 55˚C flow temperature, 20˚C room temperature).
Nu-Heat UK Ltd cannot be held liable for variation from these figures.
code description
dimension labels ‘a’ ‘b’ ‘c’ ‘d’
height
mm
width
mm
pipecentres
mm
pipe centrefrom the
wall
mm
TRB750P-C Bickleigh 750 600 750 720 102
TRB1000P-C Bickleigh 1000 600 1000 970 102
TRC600P-C Colyford 1191 600 570 102
TRCT500P-C Cotleigh 780 500 470 102
TRD520P-C Dolton 370 520 490 102
TRF300P-C Farway 300 1250 300 270 102
TRF400P-C Farway 400 1250 400 370 102
TRF520P-C Farway 520 1250 520 490 102
TRF620P-C Farway 620 1250 620 590 102
TRK400P-C Kilmington 400 (curved front) 700 400 370 102
TRK520P-C Kilmington 520 (curved front) 700 520 490 102
TRK620P-C Kilmington 620 (curved front) 700 620 590 102
TRM300P-C Musbury 300 700 300 270 102
TRM400P-C Musbury 400 700 400 370 102
TRM520P-C Musbury 520 700 520 490 102
TRM620P-C Musbury 620 700 620 590 102
TRO520P-C Oakford 700 520 490 102
TRS14/3S-C Salston 1460/275 - (3 panels) Satin Finish 1460 275 215 65
TRS14/4S-C Salston 1460/360 - (4 panels) Satin Finish 1460 360 300 65
TRS14/6S-C Salston 1460/535 - (6 panels) Satin Finish 1460 535 475 65
TRS19/3S-C Salston 1960/275 - (3 panels) Satin Finish 1960 275 215 65
TRS19/4S-C Salston 1960/360 - (4 panels) Satin Finish 1960 360 300 65
TRS19/6S-C Salston 1960/535 - (6 panels) Satin Finish 1960 535 475 65
TRU400P-C Uplyme 400 (curved front) 1250 400 370 102
TRU520P-C Uplyme 520 (curved front) 1250 520 490 102
TRU620P-C Uplyme 620 (curved front) 1250 620 590 102
TRW14/360P-C Woodbury 1460/360 1460 360 300 55
TRW14/530P-C Woodbury 1460/530 1460 530 470 55
TRW14/710P-C Woodbury 1460/710 1460 710 650 55
TRW16/360P-C Woodbury 1660/360 1660 360 300 55
TRW16/530P-C Woodbury 1660/530 1660 530
‘e’
depth
mm
115
115
115
115
115
115
115
115
115
140
165
165
115
115
115
115
115
80
80
80
80
80
80
140
165
165
75
75
75
75
75470 55
towel rail spec & dimensions www.towelrails.co.uk
* Heat output for installation directly from boiler – based on ΔT=60˚C (i.e. 80˚C flow temperature, 20˚C room temperature).** Heat output for installation on Secondary Hot Water Loop – based on ΔT=35˚C (i.e. 55˚C flow temperature, 20˚C room temperature).
Nu-Heat UK Ltd cannot be held liable for variation from these figures.
code description
dimension labels ‘f’
heat output feddirect from
boiler*
heatoutputshwl
format**
pipe centrefrom the
wall
1676 978 720
1885 1100 970
2859 1668 570
1998 1166 470
410 239 490
2106 1229 270
2368 1381 370
2500 1458 490
2729 1592 590
1449 845 370
1600 933 490
1763 1028 590
1068 623 270
1380 805 370
1500 875 490
1648 961 590
740 432 490
2154 1257 175
2839 1656 260
3676 2144 435
2805 1636 175
3715 2167 260
4210 2456 435
2486 1450 370
2600 1517 490
2841 1657 590
2406 1404 Variable
2785 1625 Variable
3498 2041 Variable
2944 1717 Variable
3408
491
552
838
585
120
617
694
733
799
425
469
517
313
404
440
483
217
631
832
1077
822
1088
1234
728
762
832
705
816
1025
863
999
weight
kg
7.1
8.6
13.5
8.4
2.66
7.5
8.3
9.38
10.88
5.4
6.72
7.8
4.8
5.2
5.6
6.66
3.9
13.1
17.6
25.8
17.5
21.5
34
8.5
9.76
11.8
12.2
18
24
13.5
20.31988
287
322
489
342
70
360
405
428
467
248
274
302
183
236
257
282
127
368
486
629
480
636
720
425
445
486
412
476
598
504
583 Variable
‘g’
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
85
85
85
85
85
80
120
120
120
‘h’
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
0
0
0
0
0
0
110
110
110
centresbtu wattsbtu watts fromtop
frombottom
TRB750P-C Bickleigh 750
TRB1000P-C Bickleigh 1000
TRC600P-C Colyford
TRCT500P-C Cotleigh
TRD520P-C Dolton
TRF300P-C Farway 300
TRF400P-C Farway 400
TRF520P-C Farway 520
TRF620P-C Farway 620
TRK400P-C Kilmington 400 (curved front)
TRK520P-C Kilmington 520 (curved front)
TRK620P-C Kilmington 620 (curved front)
TRM300P-C Musbury 300
TRM400P-C Musbury 400
TRM520P-C Musbury 520
TRM620P-C Musbury 620
TRO520P-C Oakford
TRS14/3S-C Salston 1460/275 - (3 panels) Satin Finish
TRS14/4S-C Salston 1460/360 - (4 panels) Satin Finish
TRS14/6S-C Salston 1460/535 - (6 panels) Satin Finish
TRS19/3S-C Salston 1960/275 - (3 panels) Satin Finish
TRS19/4S-C Salston 1960/360 - (4 panels) Satin Finish
TRS19/6S-C Salston 1960/535 - (6 panels) Satin Finish
TRU400P-C Uplyme 400 (curved front)
TRU520P-C Uplyme 520 (curved front)
TRU620P-C Uplyme 620 (curved front)
TRW14/360P-C Woodbury 1460/360
TRW14/530P-C Woodbury 1460/530
TRW14/710P-C Woodbury 1460/710
TRW16/360P-C Woodbury 1660/360
TRW16/530P-C Woodbury 1660/530
towel rail dimensions www.towelrails.co.uk
Bickleigh, Colyford, Cotleigh, Dolton, Farway, Kilmington,Musbury, Oakford, Uplyme.
Salston, Woodbury.
++
++
H
A fixing points
G
A
D
E
D
E
C
B
C = F
B
For pipe positions please see valve dimensions in conjunction with this information.
Nu-Heat advises that bracket positionsare taken from the towel rail once it arrives on site.
For pipe positions please see valve dimensions in conjunction with this information.
towel rail valve dimensions www.towelrails.co.uk
Towel rail valve dimensions – Pipe position will be dimension’X’ below the towel rail. (Within 5mm).+-
X = 76
X = 56 X = 42
17
X = 42
17
X = 49
21
Standard straight valves
TRSVP-C, TRSVS-C
Angled valves
TRPVP-C
Standard angled valves
TRAVP-C, TRAVS-C
Thermostatic valves straight
TRTRVS-C
Thermostatic valves angled
TRTRVA-C
Heathpark House, Devonshire Road,Honiton, Devon ex14 1sdTel: 01404 549770Fax: 01404 549771Web: www.nu-heat.co.ukEmail: [email protected]
Nu-HeatU N D E R F L O O R & R E N E W A B L E S
Standard Straight Lockshield Valves(Polished)Pipes from floor.TRSLP-C
Salston Straight Lockshield Valves(Brushed)Pipes from floor.TRSLS-C
Standard Angled Lockshield Valves(Polished)Pipes from wall. TRALP-C
Salston Angled Lockshield Valves(Brushed)Pipes from wall. TRALS-C
Standard Straight Valves (Polished)Pipes from floor.TRSVP-C
Salston Straight Valves (Brushed)Pipes from floor. TRSVS-C
Standard Angled Valves (Polished)Pipes from wall. TRAVP-C
Salston Angled Valves (Brushed)Pipes from wall.TRAVS-C
Angled Valves (Polished)Pipes from wall.Do not protrude outside dimensionsof the towel rail.TRPVP-C
• Delivery normally 3 working daysfrom placing order.
• Delivery included (UK mainlandonly).
accessories
Valves for use when plumbed on a Secondary Hot Water Loop
Valves for use when plumbed directly from boiler
www.towelrails.co.uk