total turnkey das: a path to ensure rapid business growth and career success
TRANSCRIPT
TELECOMINFRASTRUCTURE CORP
Total Turnkey DASA Path to Ensure Rapid Business Growth and
Career Success
Presenter:
Edward Donelan, RCDDPresident Telecom Infrastructure Corp
BICSI Past President
TELECOMINFRASTRUCTURE CORP
TAKE A WAYS DAS Design/Build Best Practices Growing Your Business & Improving Your Career Insider Tips for Gaining the Competitive Edge
TELECOMINFRASTRUCTURE CORP
Industry Observations
Back to the Future
BICSI Education Dashboard
MaBellBreakup Broadband
Bottleneck
Staying Relevant
TELECOMINFRASTRUCTURE CORP
Resources
• BICSI - https://www.bicsi.org/
• iBwave - http://www.ibwave.com/
• Hetnet - http://www.hetnetforum.com/
• NYSWA - http://nyswa.org/
• NEDAS - https://www.nedas.com/
• DAS Congress - http://www.dascongress.com/
• Vendor Events Verizon Wireless -http://www.ibtuf.com/
TELECOMINFRASTRUCTURE CORP
Challenges to Keep Customers HappyFigures in
parentheses refer to 2014, 2019 device share.
Source: Cisco VNI Mobile, 2015
TELECOMINFRASTRUCTURE CORP
Today’s Challenges
Process and Workflow
Perils and Pitfalls
Association and Industry events (BICSI DAS Standard, CSI Div 27)
SD, DD, CD, job commencement (Steps along the way)
TELECOMINFRASTRUCTURE CORP
787 AoA Gantt Chart
TELECOMINFRASTRUCTURE CORP
CASE STUDYMaking Opposites Attract – Design Comparisons of 787 7th Ave. and 4 Irving Place
• Completed 1986
• Granite, Limestone facade
• Concrete, Steel Structural
• Post-Modern (for the architects in the house)
• E-Glass
• Completed 1928
• Limestone Facade
• Brick, Steel Structural
• Neo-Classical
• Old Glass
TELECOMINFRASTRUCTURE CORP
Design Details787 Avenue of the Americas
• 57 Floors
• 445 Antennas
• 4 Bands, 3 Technologies
• 16 High Power Remotes (20W) AC Power
• Primarily Continuous Riser
• 3 minor changes in floor footprint
• Design Challenges: – Lobby – Atrium over 70 feet
– Concourse
– Mezzanine Offices
4 Irving Place• 35 Floors
• 202 Antennas
• 4 Bands, LTE Only
• 7 High/4 Low Power Remotes (1W) Remote DC Power
• 4 Riser Transitions
• 1 major change in floor footprint
• Design Challenges:– 19th floor, unabated areas
– Transition to bell tower floors
– Basement
TELECOMINFRASTRUCTURE CORP
Site Survey Using iBwave Note
TELECOMINFRASTRUCTURE CORP
DAS Hotels
WiFi - Cellular - 1st Responder
Fiber
High Rise
Industrial
Residential MDU
Stadium
Mall
Subway
DAS Hotel
Redundancy Diversity Backup
TELECOMINFRASTRUCTURE CORP
3 Steps Towards DAS Success
Design
1. Initial Design Visit
2. Pre-Testing (CW)
3. RF Design ( 250k-1mil sf: 250-500k increments)
4. Prepare RF BOM
5. Attend Bid Walk
6. Attend Pre-Con
TELECOMINFRASTRUCTURE CORP
Project Commencement
7. Project Management8. Material Procurement9. Make ready, cores, plywood etc.10. Equipment Installation11. Fiber Riser12. Antenna Mounting13. Horizontal Copper Coaxial cable14. Sweep & PIM Testing15. Antenna Connecting16. GPS Installation17. Head End Construction
TELECOMINFRASTRUCTURE CORP
Commissioning and Maintaining
18. Commissioning, Green Light System19. Macro Network Commissioning20. Post Test21. As Built Drawings22. Maintenance23. Upgrades
TELECOMINFRASTRUCTURE CORP
All About the BOM
• Estimating Approach– Optimistic– Most Likely– Pessimistic
• Antenna $ (Range)
Type Manufacturer Model Description Qty
Antenna Ethertronics D121014H11
Pigtail N-Type Wideband Low PIM <-153 dBc Plastic Stem and Locking Holder Mount Omni
445
Cable Generic Jumper MU Teko 30cm
Coax cable, SMA connectors 106
Cable Andrew FSJ4-50B 50 ohms - 1/2" Superflexible Foam Dielectric Coax Cable - FSJ Series
600 feet
Cable Microlab/FXR JA-10MN Jumper Cable 0.141 - Length 1.0 m - Coaxial, Low PIM, Straight N-Male to Straight N Male
313
Cable Andrew HL4RP-50 1/2" HELIAX® Plenum Rated Air Dielectric Coaxial Cable - Corrugated Copper - Blue PVDF Jacket – 50-ohm
33000 feet
Cable Generic N M - QMA M 3' Jumper Cable 3' N-Male / QMA-Male 32
Cable Corning 012E88-33131-A3
MIC® Tight-Buffered, Interlocking Armored Cable, Plenum 12 F, Single-mode (OS2) -1310/1383/1550 nm
See SOW
Miscellaneous Generic Generic Fiber Patch Panel 20
Cable Generic 1M_SMA-M QMA-M
Jumper Cable - 1m - SMA Male / QMA Male 12
Connector JMA Wireless UPL-NM-12 UPL N Male Connector for Air Dielectric Cables 1/2" Annular
1020
Connector JMA Wireless UXP-NM-12S UXP N Male Connector for Foam Dielectric Cables 1/2" Superflex
32
Connector JMA Wireless UXP-DM-12S UXP 7-16 DIN Male Connector for Foam Dielectric Cables 1/2" Superflex
64
Fiber BDA Teko Telecom T7S8A19AWWVAS
4-Band pole-mounted SMR700, AMPS850, PCS and AWS, Very High Power, AC powered, WDM, SC-APC
16
Fiber BDA Hub Teko Telecom TTRU4W-S-M 4-way MU Optical Transmitter/Receiver Module -RF-to-Optical and Optical-to-RF Conversion (698-2690MHz) with UL monitor ports
6
Type Manufacturer Model Description Qty
Filter Teko Telecom TAPOI-AWS Active Point of Interface for AWS Band - Duplex 6
Filter Teko Telecom TAPOI-SMR700L
Active Point of Interface for SMR700 Low Band -Duplex
3
Filter Teko Telecom TAPOI-SMR700H
Active Point of Interface for SMR700 High Band -Duplex
3
Filter Teko Telecom TAPOI-AMPS-TRX
Active Point of Interface for AMPS (Cell850) Band - Simplex
6
Filter Teko Telecom TAPOI-PCS-TRX
Active Point of Interface for PCS (Extended) Band -Simplex
6
Filter CCI (Communication Components Inc.)
DAST-850-6dB
60 Watt DAS Interface Tray 850 Band RF Attenuator (6 dB)
3
Filter CCI (Communication Components Inc.)
DAST-1900 60 Watt DAS Interface Tray PCS Band RF Attenuator (20 dB)
3
Miscellaneous Teko Telecom TPANEL-7TE Blank panel for Master Unit sub-rack 7TE 12
Miscellaneous Teko Telecom TPANEL-14TE
Blank panel for Master Unit sub-rack 14TE 6
Miscellaneous Teko Telecom TPSU Power Supply Module - Master Unit TPSU 4
Miscellaneous Teko Telecom TSPV Supervision Module - Embedded Web Server for System Control and Management
1
Miscellaneous Teko Telecom SUB-TRX Hosting active (Optical) Subrack Module 6
Splitter CommScope C-15-CPUSE-N-A
Directional Coupler / Unequal Splitter (0.4 dB / 15 dB) - 698-2700 MHz - N Connector
13
Splitter CommScope S-2-CPUSE-L-Ni
Multi-Band, 2-way Low Power Splitter - 698-2700 MHz - N Connectors
64
Splitter CommScope C-10-CPUSE-N-A
10 dB - Directional Coupler - 698-2700 MHz - N Connectors
181
Splitter CommScope C-6-CPUSE-N-A
Directional Coupler / Unequal Splitter (1.5 dB / 6 dB) - 698-2700 MHz - N Connectors
109
Splitter CommScope S-3-CPUSE-L-Ni
Multi-Band, 3-way Low Power Splitter - 698-2700 MHz - N Connector
13
Splitter Teko Telecom TESA5-U Esaplexer US - 5-band filter/combiner 700/800+850/900/1900/AWS
6
Splitter Teko Telecom TSC2W-U Combiner/Splitter Module 2-way, 698-2690MHz 6
Splitter CommScope S-4-CPUSE-L-Ni
Multiband, 4-Way Low Power Splitter - 698-2700 MHz - N Connector
12
TELECOMINFRASTRUCTURE CORP
FIBER BOMQTY DESCRIPTION1300 12F 8.3/125 SM OFCP ARMORED (DRAKA)
2660 2F 8.3/125 SM OFNP
600 INNERDUCT 1" PLENUM ORANGE
720 12F 8.3/125 SM OFCP ARMORED1 BLACK VELCRO 1/2"W 75' ROLL
200 12F 8.3/125 SM OFCP ARMORED
1 BLACK VELCRO 1/2"W 75' ROLL21 SINGLE PANEL HOUSING WALL MOUNT
3 WALL MOUNTABLE CLOSET HOUS
312F SPLICE TRAY HEAT SHRINK 6.9"/3.5"/0.4"
1 4U PRETIUM CONNECTOR HOUSING21 6P SC/APC SM COUPLER PANEL6 12P SC/APC SM COUPLER PANEL
2 12P SC SM DUP COUPLER PANEL COMPST 24 SC SM UNICAM CONNECTOR 8.3UM
100 SC/APC SM UNICAM CONNECTOR10 SC/APC SM UNICAM CONNECTOR2 HEAT-SHRINK SPLICE PROTECT PK/100
4 FOASSY DUP SC-SC SM 3-METER44 FOASSY DUP SCAPC-SCAPC SM 3-METER
TELECOMINFRASTRUCTURE CORP
Conclusion DAS Design Best Practices Growing Your Business &
Improving Your Career Insider Tips for Gaining
the Competitive Edge
Q&A