torsion hinged door
TRANSCRIPT
1 1160104-W2-D
These instructions must be left with the user
Installation Guide
Torsion Hinged Door
21160104-W2-D
Note! If being installed as part of an enclosure refer to the Side Panel Installation and User Guide.
Safety Information1. Careshouldbetakenwhendrillingintowallsandfloorstoavoidanyhiddenpipesor
wires.2. Westronglyrecommendthatallglasspanelsaremovedbyaminimumoftwopeople
andthatanyprotectivepackagingalongtheglassedgesiskeptinplaceforaslongaspossibletopreventdamagebeforeinstallation.
3. Duringinstallationwerecommendadditionalhelpinliftingheavydoorsandsidepanels.4. Wearprotectivefootwearwhenliftingpanels.5. Wearsafetyglasseswhendrilling.
Wall Preparation
GENERAL INFORMATION
The wa l l channe ls must be installed onto a tiled or waterproof finished flat and evenwallsurface.Failuretodosowillresultinanunsatisfactoryseal,whichmaycausepropertydamage.
INTRODUCTIONThankyouforpurchasingaqualityKOHLER®product.Toenjoythefullpotentialofyournewproduct,pleasetaketimetoreadthisguidethoroughly,havingdoneso,keepithandyforfuture reference.Thefollowingpagesaimtoprovidecomprehensiveinstallationinstructions,plusadviceonhowtocareandmaintainyourproduct.Werecommendthattheunitisinstalledbyaqualifiedplumberorengineer.
General1. Readalloftheseinstructionsandretainthisguideforlateruse.2. Passonthisguideintheeventofchangeofownershipoftheinstallationsite.3. Followallwarnings,cautionsandinstructionscontainedinthisguide.4. Removeallprotectivetapefromtheenclosurebeforeinstallation.
3 1160104-W2-D
TOOLS REQUIRED
3.0 mm6.0 mm
2.0 mm 2.5 mm 5.0 mm
GUARANTEEFordomestic installations,yourenclosurehasthebenefitofourlifetimeguaranteewhichstarts from date of purchase.
Fornon-domestic installations,weguaranteetheproductagainstanydefectinmaterialsorworkmanshipforaperiodofoneyearfromthedateofpurchase.
Fortermsandconditionsrefertothebackcoverofthisguide.
RecommendedUsageDomestic ü
LightCommercial ü
HeavyCommercial û
Healthcare û
41160104-W2-D
Ticktheappropriateboxestofamiliariseyourselfwiththepartnamesandtoconfirmthat all of the parts are included.
Documentationq1xGuaranteeRegistrationDocument
q 8 x Wall Plugs
q 2 x Wall Channels
q8xFixingScrews
q4xPlasticCovers
q 8 x Screws
q2xCoverStrips
q 1 x Hinged Door
PACK CONTENTS
q 1 x 3 mm Drill
q 1 x 2 mmHexagonal Wrench
q 1 x 5 mmHexagonal Wrench
q8xCoverPanelClips
Note! Pack Contents the same for 1000/1200 Hinge Door
q 1 x 2.5 mmHexagonal Wrench
q1xLintelCap
5 1160104-W2-D
x 1
x 2
x 1
PACK CONTENTS CONTINUED
x 1
x 1
x 1
x 1
Handle Pack Geometric
Handle Pack Twisted
OR
61160104-W2-D
INSTALLATION
Note!Coverthetraywastetopreventthelossofsmallparts. Note!Protectthetraysurfaceduringenclosureinstallation.
1
± 0 mm
20 mm
Note! Make sure that the wallshavebeentileddowntothetray.
Height of Enclosure (mm) 1952
Min/Max Frame Adjustment Enclosure Size Minimum (mm) Maximum (mm)700 660 700
760 720 760
800 760 800
900 860 900
1000 960 1000
1200 1160 1200
(a) Installtheshowertrayinaccordancewiththemanufacturer’sinstructions. Caution!Makesurethattheshowertrayislevelandthatthewallsarevertical
andsquare.
7 1160104-W2-D
(a) Usinga suitable tool, cut and remove the zip tie.Makesure that thedoorremainsclosedwhenmoving/positioningthedoor.
(b) Removethewallchannel.
2
81160104-W2-D
(a) Positionthewallchannel(handleside)onthewall.Usingaspiritlevelmakesure that it is upright.
(b) Markthepositionofthefixingholes,thenremovethewallchannel.(c) Drillwitha6mmmasonrybit (notsupplied)andplugusing thewallplugs
(supplied).
3
20 mm
± 0 mm
6 mm
x4
x4
x4
9 1160104-W2-D
(a) Positionthesecondwallchannel(hingeside)onthewall.Usingaspiritlevelmake sure that it is upright.
(b) Markthepositionofthefixingholes,thenremovethewallchannel.(c) Drillwitha6mmmasonrybit (notsupplied)andplugusing thewallplugs
(supplied).(d) Positionthewallchannelonthewallandinstallthefixingscrews.(e) Fullytightenthefixingscrews,makingsurethattheU-channelisupright.
4
20 mm
± 0 mm6 mm
x4
x4
x4
101160104-W2-D
(a) Installthefirstwallchanneloverthedoorframeandholdinposition.
5
LH
11 1160104-W2-D
(a) Install the door frame into the wall channel that had been secured to the wall earlier.
(b) Adjust the door frame so that it is in the correct position.
6
121160104-W2-D
(a) Openthedoorandremovetherubbersealingstrip.(b) Installthewallchannelfixingscrewsthroughtheaccessholesinthedoorframe.(c) Fullytightenthefixingscrews,makingsurethatthewallchannelisupright.(e) Refittherubbersealingstrip.
57
13 1160104-W2-D
(a) Centralise the door frame within the wall channels, making sure that the door frameissquare.
58
± 0 mm
141160104-W2-D
(a) Drill four 3 mm holes from inside the shower enclosure in the door frame through the pre-drilled holes in the wall channel with the 3 mm HSS drill (supplied).
(b) Install the screws.(c) Tighten the screws.(d) Repeattheprocessfortheotherwallchannel.(e) Applysealantinaccordancewiththesealantmanufacturersinstructionsalong
theinsidesurfacesofthewallchannelsonly.
59
3 mm
x4
x4
Make sure these edges areflush
15 1160104-W2-D
(a) Installthecoverpanelclips(4off).(b) Installthecoverpanelintothecovelpanelclipsuntilflushwiththewall.
x4
510
161160104-W2-D
511
(a) Partiallyremovethedoorsealingstripsasshownabove.(b) Applyasmallamountofsealantinaccordancewiththesealantmanufacturers
instructionsasshownabove.(c) Fit the door sealing strips back in position.Remove any excess silicone
sealant.
17 1160104-W2-D
512
x 1
x 2
x 1
2.0 mm
Handle Pack Geometric
a b
c
181160104-W2-D
a b
x 1
x 1
x 1
x 1
2.0 mm
2.0 mm
Handle Pack Twisted
c
513
19 1160104-W2-D
514
1
2
(a) Applysealantinaccordancewiththesealantmanufacturersinstructionsalongtheoutsidesurfacesofthedoorframeonly.
(b) Allow the silicone sealant to cure for 24 hours before use.(c) Fittheplasticcoverstothetopoftheextrusions.(d) Fitthelintelcap
24hrs
201160104-W2-D
(a) Ifnecessary,adjustthedoorcatchasshownabove.
515
516
(a) Ifthedoorisoutofsquare,adjustasshownabove.
21
3
21
3
21 1160104-W2-D
MAINTENANCEGeneral MaintenanceProviding the shower enclosure hasbeen correctly installed and is operated inaccordancewith the instructions contained in this guide, difficulties should notarise.
Ifanymaintenanceisrequiredthenitmustbecarriedoutbyacompetenttradespersontowhomthemaintenanceinstructionsareprovided.
Beforereplacinganypartsensuretheunderlyingcauseofthemalfunctionhasbeenresolved.
CleaningWarning!Manyhouseholdcleanerscontainabrasiveandchemicalsubstancesandshouldnotbeusedforcleaningpainted,platedorplasticfittings.Thesefinishesshouldbecleanedwithamildwashingupdetergentorsoapsolutionandthenwipeddryusingasoftcloth.
CareTopreservethebeautyofyourshowerenclosureformanyyears,pleaseobservethe following care instructions:
Rinseglassand framewithclearwateraftershowering.Removewaterdropletswithasqueegee.Donotrubdry!Tocleanyourshowerhygienicallyandeasily,werecommend the use of a biodegradable cleanser.
Regular cleansingwith a biodegradable cleanser prevents stubborn stains andensuresacleanandhygienicsurfaceformanyyears.Donotusescouringorcausticcleansersunderanycircumstances!Thesecandamagethesurfaceoftheframe,glassanddecorativepartsaswellastheplasticparts.
Chrome PartsUseonlycleansersexpresslyspecifiedforchrome!
221160104-W2-D
SPARE PARTSLH Hinged Door - 700 - 900
1
2
2
34
5
5
GeometricHandle
TwistedHandle
3
4
3
23 1160104-W2-D
1 1795.132 HingedAssemblyLH700TwistedSpare
1795.134 HingedAssemblyLH760TwistedSpare
1795.136 HingedAssemblyLH800TwistedSpare
1795.138 HingedAssemblyLH900TwistedSpare
1795.140 HingedAssembly700GeometricSpare
1795.141 HingedAssembly760GeometricSpare
1795.142 HingedAssembly800GeometricSpare
1795.143 HingedAssembly900GeometricSpare
2 1795.129 Door Top Cap Pack
3 1795.144 HingeSealKit
4 1795.157 Torsion Door Ball Catch Spare
5 1795.146 Door Wall Channel Spare
LH Hinged Door - 700 - 900
241160104-W2-D
RH Hinged Door - 700 - 900
1
2
2
34
5
5
GeometricHandle
TwistedHandle
3
4
3
25 1160104-W2-D
1 1795.133 HingedAssemblyRH700TwistedSpare
1795.135 HingedAssemblyRH760TwistedSpare
1795.137 HingedAssemblyRH800TwistedSpare
1795.139 HingedAssemblyRH900TwistedSpare
1795.140 HingedAssembly700GeometricSpare
1795.141 HingedAssembly760GeometricSpare
1795.142 HingedAssembly800GeometricSpare
1795.143 HingedAssembly900GeometricSpare
2 1795.129 Door Top Cap Pack
3 1795.144 HingeSealKit
4 1795.157 Torsion Door Ball Catch Spare
5 1795.146 Door Wall Channel Spare
RH Hinged Door - 700 - 900
261160104-W2-D
LH Hinged Door - 1000 - 1200
GeometricHandle
1
2
2
3
4
5
3
4
5
3
3
TwistedHandle
27 1160104-W2-D
1 1795.136 HingedAssemblyLH800TwistedSpare
1795.138 HingedAssemblyLH900TwistedSpare
1795.142 HingedAssembly800GeometricSpare
1795.143 HingedAssembly900GeometricSpare
2 1795.129 Door Top Cap Pack
3 1795.145 HingeSealKit
4 1795.157 Torsion Door Ball Catch Spare
5 1795.146 Door Wall Channel Spare
LH Hinged Door - 100 - 1200
281160104-W2-D
RH Hinged Door - 1000 - 1200
GeometricHandle
1
2
2
3
4
5
3
4
5
3
3
TwistedHandle
29 1160104-W2-D
RH Hinged Door - 100 - 1200
1 1795.137 HingedAssemblyRH800TwistedSpare
1795.139 HingedAssemblyRH900TwistedSpare
1795.142 HingedAssembly800GeometricSpare
1795.143 HingedAssembly900GeometricSpare
2 1795.129 Door Top Cap Pack
3 1795.145 HingeSealKit
4 1795.157 Torsion Door Ball Catch Spare
5 1795.146 Door Wall Channel Spare
301160104-W2-D ©KohlerCo.March2013
0044 844 571 0048
Kohler Mira LimitedCustomer Services Dept,1 Penrose Place,Skelmersdale,WN8 9PR
To Contact Us: UK
Fax: 0044 844 571 7157
CUSTOMER SERVICE
E-mail: [email protected]
To Contact Us: Eire Only
0844 571 0048
Fax: 0844 571 7157
Helpdesk ServiceOur Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit.
We will need you to have your model name, model number and date of purchase.
KOHLER® Website (www.KOHLER.co.uk)From our website you can download additional user guides or request a service visit.
Spares and AccessoriesWe hold the largest stocks of genuine Kohler spares and accessories.Contact us for a price and to purchase spares or accessories.
Service / RepairsNo one knows our products better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the guarantee period.
Ask about our fi xed price service repairs.
GuaranteeYour enclosure has the benefi t of our lifetime guarantee which starts from the date of purchase.To activate this guarantee, you must return your completed registration card with a copy of proof of purchase from an approved Kohler retailer within 30 days of purchase.This guarantee is in addition to your statutory rights and is subject to conditions (see registration card).
What to do if something goes wrongIf your product does not function correctly when you fi rst use it, contact your installer to check that it is installed in accordance with the instructions in this manual.
If this does not resolve the issue, contact our Customer Services Team who will offer you or your installer help and advice.
Kohler Mira Limited, Cromwell Road, Cheltenham,Gloucestershire, GL52 5EP, UK
13EN 14428:2004 + A1: 2008
By Post:
Kohler is a registered trade mark.The company reserves the right to alter product specifi cations without notice.