tops ccc remote i/o module tops ccc products co., ltd. expert ®

26
TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD. www.topsccc.com EXPERT ®

Upload: kevin-rice

Post on 22-Dec-2015

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

REMOTE I/O MODULE

TOPS CCC PRODUCTS CO., LTD.

www.topsccc.com

EXPERT®

Page 2: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

RS485 CONVERTER

EX9520/A/R/AREX9520/A/R/AR

““Autopro”Autopro”

• Multiple baud rate / Multiple data format

• Free under RS485 Network not need to change by DIP SW. ADVANTECH?

Page 3: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

RS485 REPEATER

• 256 Modules Max in one RS485 network w/o Repeater

• Isolation on Every Module

Isolation

DeviceRS485

For protection the Device

Page 4: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

FOR DIO, AIO INIT*

• POWER OFF

• INIT* PIN TO GND

• POWER ON

Module status

Address: ø ø , baud rate: 9600bps no

check sum

Page 5: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Module Status & Reset Status

Module Power on Reset or Module WDT

Timeout H/W Reset

Module O/P

Power on Value Host WDT Timeout (s/w)

Module O/P

Safe Value

Page 6: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Dual WDT (watch dog timer)

• Module WDT is H/W reset CKT module work continue (never halt)

• Host WDT is S/W func.Module O/PSafe Value

EXPERT®

Page 7: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Digital O/P

• Safe Value

• Power on Value

• O/P Command ValueHost WDT NO Timeout & Module WDT

NO Timeout then user issue a digital

O/P Command.

Page 8: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Latch Digital I/P

A B

EXPERT®

Page 9: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

A I O

• Digital I/P & Event Counter

=>Counter update

16-bit width

Page 10: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

H/L AlarmIndustry Alarm Function.

Analog Value

>Hi Alarm Value

<Lo Alarm Value

Module’s

as Comparator

Page 11: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Transmitter

Sensor

Driver CKT &

Compensation CKT

Amp &

Energy

4-20 mA

0-5V

Example:

2-wire

-- power I/P , 4-20mA current O/P3-wire – power I/P, GND, 0-5V O/P

Page 12: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Linear Mapping (translate / covert)

I/P ( A/I: Analog I/P )

Desired O/P

(Physical quantity)

EXPERT®

Page 13: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Thermocouple Measurement

JunctionMetal A

Metal B

heat

heat

See Beck

Voltage

Physical

Thermistormeasure

Junction Temperature

Junction temperature Junction Voltagem

Page 14: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Thermocouple Measurement

Junction Voltage

Thermo couple Voltage m

mSee Beck

Voltage

See Bade Voltage TemperatureCalculate

EXPERT®

Page 15: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

EX9188XD series

EX9188AD/BD/CD (Flash Rom & RAM)

--PC or PLC (Industrial control)

--COM*4 (ADVANTECH COM*2)

--User can use “Control program” to Download or Upload COM4

EXPERT®

Page 16: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Block Diagram

Page 17: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Spec. of EX9188AD

• AMD 80188-40 MHz

• SRAM 256KB

• FLASH ROM 512K

• COM1-COM4

• MiniBIOSDatalight

• ROM DOSDatalight

Page 18: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

Hyper Terminal

• Under Hyperterminal to Execute the DOS command

DOS

COMM.exe EX9188AD

Hyperterminal

Page 19: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

File Transfer

• Download or Upload

• Transfer.exeDos

• xm.extHyperterminal

EXPERT®

Page 20: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

• ROMDISK.EXE ROMDOS’S UTILITY MAKE ROMDISK.IMG (TO ROM, VDISK….)• TOROM.EXT ROMDISK.IMGFLASH ROM• VDISK A: FLASH ROM B: SRAM (Virtual Disk)

Page 21: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

9188LiB• LiB (Source code)

• DEMO

For user application

EXPERT®

Page 22: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

EX9188END series• EEthernet

• N1-8 COM PORT

• D7 Segment Display

• Converter (RS485 to TCP/IP)

• EX9188XD W/ETHERNET FUNCTION

• Let your device to connect to Internet

Page 23: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

EX9188END series

PC EX9188END

EX9000

EX9000

device1

device8

1.

8.COM1

COM2

COM256 EXPERT®

Page 24: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

EX8000 series2003 March

• EX8000— 4AIO, DIO — 8AIO, DIO — 16AIO, DIO

RS232/RS485/ETHERNET• NEW CONVERTEROK Ethernet FiberOK RS232/RS485 FiberOK Radio Modem RS232/RS485? CAN RS232/RS485

Page 25: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

OEM/ODM

Our R&D team is profession on system

control for :

1. Valve Control

2. Factory Automation

3. Building/Office Automation

4. Sensing Element Design

5. Electronic-Hydraulic

Page 26: TOPS CCC REMOTE I/O MODULE TOPS CCC PRODUCTS CO., LTD.  EXPERT ®

TOPS CCC

THE END.

Q&A TIME