top view - hearth n home...birmingham 50" wood fireplace top view front view left side view...
TRANSCRIPT
16-1/8"[408]
Gas LineKnockout
11-1/8"[282]
6-7/8"[175]5"
[129]
16-1/8"[408]
11-1/8"[282]
6-7/8"[175] 5"
[129]
50" [1270]60-7/8" [1546]
3-3/4[97]
38"[965]
54"[1372]
74-1/8"[1883]
70-3/4"[1797]
45-1/8"[1146]
11"[281]
27-1/2"[699]
74° TYP.
Gas LineKnockout
22-1/2"[572]
61-7/8"[1572]
5-1/2"[140]
Please consult the manufacturer’s installation manual for all details and requirements before making a final
design layout decision.
Birmingham50" Wood Fireplace
Top View
Front View
Left Side View Right Side View
Specifications
Additional information can be found online at www.heatilator.com or fireplaces.com
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
BIR50-BActual Framing Actual Framing Actual Framing Actual Framing
50 x 3860-7/8 61-7/8 45-1/8 61-7/8 74-1/8 74-1/2 27-1/2 28-1/2
BIR50-B
CLEARANCES TO COMBUSTIBLES
FRAMING DIMENSIONS
MANTEL LEG/WALL PROJECTIONS
HEARTH EXTENSION CONSTRUCTION
APPLIANCE LOCATION
MANTEL PROJECTIONS
HEARTH EXTENSIONS
73 [1854]
51-5/8"[1311]
61-7/8"[1572]103-1/4"[2623]
1/2" [13] allconfigurations
In an exterior chaseor prjecting into a
garage
Across acorner
Along a wall
92"[2337]
61-7/8" [1572]
25-1/4"[641]
48"[1219]
minimum
24" [610]from fireplace opening toany perpendicular wall
85-7/8" [2181]
61-7/8" [1572]85-7/8" [2181]
28-1/2"[724]
28-1/2"[724]
28-1/2"[724]
61-7/8"[1572]
))))))))))))))))))))))))
)))))))))))))))))))) ))
))))))))))))))))))))))
)))))))))))
)))))))))))
)))))))))))) ))))))))
As aroom
divider
RUTHERFORD-50
*28-1/2"[724]
**74-1/2"[1892]
61-7/8"[1572]
2" [51] minimumair spaceclearance fromchimney
Framing must be extended straight up 84" [2134] frombase of fireplace.
Extra space needed for outside air connection. If outside air duct has no bend, this dimension maybe reduced as long as minimumclearances are met.
12"[305]
21" min[533]
12"[305]
* If interior of chase will be drywalled, add the thickness to this measurement.** Adjust header height for raised floor under fireplace.
50° a
ngle 39° angle
BRICKFRONT
FLUSHFRONT
18-1/2"[470]
19-3/4"[500]
4" [102]
24"[610]
24"[610]
22-3/8"[568]
60-7/8" [1546]
50" [1270]
* 2" [51]
Continuous,non-combustible sealant
Tile, stone or othernon-combustible material
Floor constructed of wood orother combustible material
1" Micore or equivalentinsulation (see InstallManual)
Fire
plac
e
ProtectiveMetal HearthStrip
1/2" Durock
**
The bottom of the fireplace opening is 3-3/4" [95]above the bottom of the fireplace. Finished hearthextension must NOT extend above this level.
74"[1880]
50"[1270]
12"[305]
12"[305]
20" [508] min raised30" [762] min flush
(R value of hearth must beequal to or greater than 2.32)
(insulation)
0" to level ofstandoffs
Attic Insulation Shield
(ceiling)
(roof)
(attic)
(ceiling)
Attic Shield Collar
Ceiling Firestop
Storm CollarChase Top Flashing
1-1/2" [38] to back &sides of appliance (except at nailing flangeswhere it is 1/2" [13])
Must have 2" [51] minimumclearance to any cumbustiblematerials including header
0" to floor
2" [51] minimum
Shaded areas represents2" [51] minimum air spaceclearance required aroundpipe.
Com
bust
ible
Obj
ect
48"[1219]
1" [25]
7 ft [2134]minimum
floor to ceiling
Grid represents1" squares
Notches
2 x 4 stud header
Standoffs
Measured from top of fireplace opening
12" [305]
22" [559]minimum
Combustible Wall & Decorative Facing
1-1/2" [38]maximum
Seal joint withnon-combustible sealant
12" [305]minimum
6" [152]minimum
Non-combustibleDecorative Facingsuch as:steel, iron, brick,tile, concrete, slate,glass, plasters.
Mantel
Specifications
WS/HTL/BIR50_1015
Additional information can be found online at www.heatilator.com
Lakeville, MN Phone: (800) 927-6841 Web: www.heatilator.com
PRODUCT LISTING CODES
US UL 127
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
BIR50-B