toc analyser - minitoc-arrowlabs.net/resources/brochures/minitoc short presentation.pdf · toc...
TRANSCRIPT
![Page 1: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/1.jpg)
TOC Analyser - MiniTOC-
membraPure GmbH Wolfgang-Küntscher Straße 14
16761 Hennigsdorf
![Page 2: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/2.jpg)
membraPure GmbH founded 1993
office building production hall Product range:
2 22.11.2018
![Page 3: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/3.jpg)
TOC Analyser
measurement range 0.1 - 1000 ppb
cell constant accuracy 1.5%
temperature sensor : PT 1000
temperature accuracy: +/- 0.25 K
ports 1 for sample, 1 for SST (Basic)
1 for sample, 3 for SST (Professional)
max. conductivity of sample:
< 2 μS/cm (online)
3 22.11.2018
![Page 4: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/4.jpg)
TOC Analyser
sample volume flow 14 ml/min
analysis time 2 sec
inlet pressure < 0.5 bar otherwise
pressure reducer
sample temperature 10 - 50 °C if
more than heat exchanger
particles < 100 micron
4 22.11.2018
![Page 5: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/5.jpg)
TOC Analyser
Housing
dimensions (w x d x h)
300 mm x 200 mm x 500 mm
weight 14 kg
protection: IP 54 (option)
Operating Conditions
power supply 110 - 230 VAC, 50 Hz
power consumption < 50 W
ambient relative humidity 10 - 95 %
altitude : up to 3500 m 5 22.11.2018
![Page 6: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/6.jpg)
TOC Analyser
Configuration
control internal PC, 8“ TFT touch screen
monitor
operating system Windows 7 embedded
software miniTOC control software for
measurement, qualification, diagnosis
interfaces USB 2.0, analogue out (option)
6 22.11.2018
![Page 7: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/7.jpg)
Design
UV-Reactor
Pump
Conductivity sensors
Valves
7 22.11.2018
![Page 8: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/8.jpg)
Scheme fluidic
8 22.11.2018
![Page 9: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/9.jpg)
Fluid connections
9 22.11.2018
![Page 10: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/10.jpg)
Menu
10 22.11.2018
![Page 11: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/11.jpg)
Online measurement
11 22.11.2018
![Page 12: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/12.jpg)
Calibration - start
12 22.11.2018
![Page 13: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/13.jpg)
Calibration- finished
Factor & R²
Measured data
Calibration curve
13 22.11.2018
![Page 14: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/14.jpg)
SST - start
14 22.11.2018
![Page 15: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/15.jpg)
Viewer
15 22.11.2018
![Page 16: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/16.jpg)
Interval Mode MiniTOC pro
16 22.11.2018
![Page 17: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/17.jpg)
Service Change UV-Reactor: Plug out power supply Remove plug connection Unscrew fluidic tubes Take reactor out of holder
Change pump tube: Open cable ties Remove fluidic lines from
pump tube Open pump clamps, remove
tube by turning pump manually
Reset hourmeters for pump tube and UV Lamp!!
17 22.11.2018
![Page 18: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/18.jpg)
Installation
waste
Cooler (if T > 50 °C)
Option:
Pressure reducer
p ≈ 0.25 bar
connector ¼“ -28 UNF
connector ¼“ BSP x 6 mm
Water Connection
connector
Gate valve with
Adapter 6 mm
Tube 6 mm AD
Tube 1/8“ 3.2 mm AD
18 22.11.2018
![Page 19: TOC Analyser - MiniTOC-arrowlabs.net/resources/brochures/MiniTOC short presentation.pdf · TOC Analyser measurement range 0.1 - 1000 ppb cell constant accuracy 1.5% temperature sensor](https://reader033.vdocuments.mx/reader033/viewer/2022052805/6056b818684ab4379b249405/html5/thumbnails/19.jpg)
Installation
19 22.11.2018