FEATURES
APPLICATIONS
· TMS 114 UF (non-thermal) and 114T UF (thermal barrier) are front setflush glazed systems that are 4 1/2" deep with a 2" wide sightline
· Front face of glass is 3/4" from face of system· Glaze from the outside or inside· Screw spline or shear block fabrication· Glazing options up to 1-1/8" thick· Available in anodized and standard or custom painted finishes· Readily available from stock
· Storefront, Punched Openings, or Ribbon Windows· Single span· Integrated entrance framing to allow Pittco standard entrances
or other speciality entrances to be incorporated
SYSTEM PERFORMANCE (TMS 114 UF Non-Thermal)Description Test Method Allowed Achieved Test Report
Structural ASTM E 330 25 psf 22-03Air ASTM E 283 0.06 cfm/ft2 @ 6.24 psf 0.05 cfm/ft2 @ 6.24 psfWater (Static) ASTM E 331
AAMA 501.1None @ 5 psfNone @ 5 psf
None @ 10 psfNone @ 10 psf
N/A
SYSTEM PERFORMANCE (TMS 114T UF Thermal)Description Test Method Allowed Achieved Test Report
Structural ASTM E 330 25 psfAir ASTM E 283 0.06 cfm/ft2 @ 6.24 psf 0.05 cfm/ft2 @ 6.24 psf
ASTM E 331AAMA 501.1
None @ 5 psfNone @ 5 psf
None @ 10 psfNone @ 10 psf
CRFU Value
N/A
* 1" IGU (1/4-1/2-1/4) Clear Annealed Glass, Air Filled, Aluminum Spacer.** Based on TMS center glazed system
AAMA 1503AAMA 1503
N/AN/A
22-04560.60 22-04
Water (Dynamic)
Water (Static)Water (Dynamic)
22-0322-0322-03
22-0322-0322-0322-03
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
FEATURES
1
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
BLANK PAGE
2
EXPLODED VIEWS PAGE 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4 SIZE DETAILS - TMS 114 UF NON THERMAL PAGES D1 TO D4. . . . . . .
WINDLOAD CHARTS PAGES S1 TO S4. . . . . . . . . . . . . . . . . . . . . . . . . . . . DEADLOAD CHARTS PAGE S5. . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION PROPERTIES PAGE S6. . . . . . . . . . . . . . . . . . . . . . . . . .
1/4 SIZE DETAILS - TMS 114T UF THERMAL BARRIER PAGES D5 TO D8. . ENTRANCE DETAILS PAGE D9. . . . . . . . . . . . . . . . . . . . . . . . . . . .
THERMAL CHARTS PAGES T1 TO T2. . . . . . . . . . . . . . . . . . . . . . . . . .
PRODUCT DESCRIPTION - THERMAL BARRIER PAGES 9 TO 13 . . . . . . . .PRODUCT DESCRIPTION - NON THERMAL PAGES 4 TO 8 . . . . . . . . . . .
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
INDEX
3
● BASIC USES / RELATED USESFraming is designed for flush glazed, up-front glazed storefront assemblyVertical mullions are typically open back aluminum members, with solid face and flush closure plates forming tubular members for useon single spansHorizontal mullions are of hollow aluminum with removable glazing stopsCorners are configured for 90 degreesGlazing is insulating glass unit or single pane with adaptersGlass may be transparent, opaque, or decorative typesFraming is intended for one story applicationsFramed assembly may be fitted to most rigid and stable framed opening assemblies
● PRODUCT ATTRIBUTES AND CHARACTERISTICSFraming and glazing stops are designed for glass and panelsWind pressure resistance and pressure equalization are standard within the frame assemblyWeep containment, condensate water collection, and drainage to the exterior at concealed weeps are standardIntegral door frames are available
● SELECTION CRITERIAQuality, economy, and good performance are provided at a reasonable costFraming is designed for Interior or exterior environments
● APPLICABLE STANDARDS, RELATED REFERENCESAA (Aluminum Association) - Designation System for Aluminum FinishesAAMA SFM-1-87 - Aluminum Storefront and Entrance ManualAAMA 501.1-05 - Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors using Dynamic PressureAAMA 611-98 - Voluntary Specification for Anodized Architectural AluminumAAMA 1503-98 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows,Doors, and Glazed Wall SectionsAAMA 2604-05 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings onAluminum Extrusions and PanelsAAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatingson Aluminum Extrusions and PanelsASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate [Metric]
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
NON-THERMAL PRODUCT DESCRIPTION
4
ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and TubeASTM B221M - Standard Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and Tube [Metric]ASTM E283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under SpecifiedPressure Differences Across the SpecimenASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static AirPressure DifferenceASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air PressureDifference
● QUALITY, TESTS, CERTIFICATIONS, AND APPROVALSAir Infiltration: Maximum leakage of 0.05 cfm/sq ft. when measured in accordance with ASTM E283 at a test pressure of 6.24 psfStatic Water Leakage: No uncontrolled leakage, when measured in accordance with ASTM E331 at a test pressure difference of 10.0 psfDynamic Water Leakage: No uncontrolled leakage, when measured in accordance with AAMA 501.1 at a test pressure difference of 10.0 psfStructural Performance: Maximum deflection less than 1/175 of the span length and no damage to the assembly, when measured in accordancewith ASTM E330 at a test pressure of 25 psf
● PACKAGING, HANDLING, AND PROTECTION INSTRUCTIONSPackaged in specially designed heavy cartons or shipped pre-fabricated and assembled
● SPECIAL WARRANTYOne (1) year
● LIMITATIONSNot thermally brokenFraming is limited to applications of one story in heightNot intended for continuous members for multiple floor applications
● SAFETY PRECAUTIONSNormal precautions required
● AVAILABILITYFraming is available in all regions of USA - refer to Internet web site for locations and addresses of distributors
● COSTVaries with elevation, configuration and finish desired
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
NON-THERMALPRODUCT DESCRIPTION
5
PRODUCT PROPERTIES● MATERIAL AND DESIGN
Aluminum: 6063-T6 alloy and temper, to ASTM B221 or ASTM B221MFasteners: Stainless steel, or zinc plated carbon steelPerimeter Anchors: Aluminum, or steel that will be isolated from aluminum componentsGlazing Gaskets: Wedge-type, Ethylene Propylene Diene Monomer (EPDM) rubber with non-stretch cordGlass Stops: Snap-in type
● SHAPE AND DIMENSIONSFrame Size: 2 x 4-1/2 inchGlass Edge Bite: 3/8 inchGlazing Thickness Accepted: 1/8 inch to 1-1/8 inch in increments of 1/16 inch except 7/16 inch, 9/16 inch, 11/16 inch, and 13/16 inch
● SHOP FABRICATION AND ASSEMBLYProvide for flush glazing on all sides with no projecting stopsConfigurations:■ Two-piece snap together mullions■ Solid tubular mullions, assembled to specially designed shear block clipsAccessories:■ Expansion Mullions■ Corner Mullions■ Open Back Perimeter Members■ Integral Door Frames■ Flashing, Subsills■ Head Receptor■ Heavy Duty Mullions■ Standard Steel Reinforcing
● COLORS AND TEXTURES■ Architectural anodic coating, in accordance with AAMA 611;
o Aluminum Association Designation.□ AA-M10C22A31 - Class II - (Pittco #42 Clear)□ AA-M10C22A41 - Class I - (Pittco #43 Clear)□ AA-M10C22A44 - Class I - (Pittco #59 Champagne)□ AA-M10C22A44 - Class I - (Pittco #60 Light Bronze)□ AA-M10C22A44 - Class I - (Pittco #61 Medium Bronze)□ AA-M10C22A44 - Class I - (Pittco #62 Dark Bronze)□ AA-M10C22A44 - Class I - (Pittco #63 Black)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
NON-THERMAL PRODUCT DESCRIPTION
6
■ Architectural organic coating, in accordance with AAMA 2604 (50% Kynar 500®);o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2604, High Performance
Organic Coatings on Aluminumo Type: Factory Applied, High Performance, 50% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, and
applied by Paint Manufacturer's Warranty-Approved Applicatoro Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides,
followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminumo Specify color code, e.g. UC 40577(Duranar Black)
■ Architectural organic coating, in accordance with AAMA 2605 (70% Kynar 500®);o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2605, Superior Performing
Organic Coatings on Aluminumo Type: Factory Applied, High Performance, 70% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, and
applied by Paint Manufacturer's Warranty-Approved Applicatoro Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides,
followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminumo Specify color code, e.g. UC 40577(Duranar Black)
PRODUCT PLACEMENT● PREPARATION WORK
Ensure openings are of proper size, and are plumb, square, level and in the proper location and alignment
● INSTALLATIONAlign installed assembly plumb and level, free of warp or twistMaintain dimensional tolerances, aligning with adjacent workSeal joints between framing and building structure watertightFollow guidelines in Pittco Fabrication, Sealant and Erection Brochure
● START-UP AND OPERATIONNot Applicable
● OWNER'S MAINTENANCE INSTRUCTIONSWash surfaces with warm water and mild soap; wipe clean, at least once a year
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
NON-THERMALPRODUCT DESCRIPTION
7
Corporate IdentificationPittco Architectural Metals, Inc
1530 Landmeier RoadElk Grove Village, Illinois 60007Tel: (847) 593-3131Fax: (847) 593-9946Toll-Free: (800) 992-7488Internet: http://www.pittcometals.comE-mail: [email protected]
Technical Services AvailableToll-Free: (800) 992-7488
Classification and FilingMasterFormat
Subset of Section 08410 - Metal Framed StorefrontsUniFormat
Section B2030 - (exterior entrance frames) or C1020 (interior entrance frames)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
NON-THERMAL PRODUCT DESCRIPTION
8
● BASIC USES / RELATED USESFraming is designed for flush glazed, up-front glazed storefront assemblyVertical mullions are typically open back aluminum members, with solid face and flush closure side plates forming tubular members for use onsingle spansHorizontal mullions are of hollow aluminum with removable glazing stopsGlazing is insulating glass unit or single pane with adaptersCorners are available for 90 degreesGlass may be transparent, opaque, or decorative typesFraming is intended for one story applicationsFramed assembly may be fitted to most rigid and stable framed opening assemblies
● PRODUCT ATTRIBUTES AND CHARACTERISTICSAluminum frame members are thermally improvedFraming and glazing stops are designed for glass and panelsWind pressure resistance and pressure equalization are standard within the frame assemblyWeep containment, condensate water collection, and drainage to the exterior at concealed weeps are standardIntegral door frames are available
● SELECTION CRITERIAQuality, economy, and good performance are provided at a reasonable costFraming is designed for Interior or exterior environments
● APPLICABLE STANDARDS, RELATED REFERENCESAA (Aluminum Association) - Designation System for Aluminum FinishesAAMA SFM-1-87 - Aluminum Storefront and Entrance ManualAAMA 501.1-05 - Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors using Dynamic PressureAAMA 611-98 - Voluntary Specification for Anodized Architectural AluminumAAMA 1503-98 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors, and Glazed Wall SectionsAAMA 2604-05 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on AluminumExtrusions and PanelsAAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings onAluminum Extrusions and PanelsASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate [Metric]ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and TubeASTM B221M - Standard Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and Tube [Metric]
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
NON-THERMALPRODUCT DESCRIPTION
9
ASTM E283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under SpecifiedPressure Differences Across the SpecimenASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static AirPressure DifferenceASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air PressureDifference
● QUALITY, TESTS, CERTIFICATIONS, AND APPROVALS
Air Infiltration: Maximum leakage of 0.05 cfm/sq ft. when measured in accordance with ASTM E283 at a test pressure of 6.24 psfStatic Water Leakage: No uncontrolled leakage, when measured in accordance with ASTM E331 at a test pressure difference of 10.0 psfDynamic Water Leakage: No uncontrolled leakage, when measured in accordance with AAMA 501.1 at a test pressure difference of 10.0 psfStructural Performance: Maximum deflection less than 1/175 of the span length and no damage to the assembly, when measured in accordancewith ASTM E330 at a test pressure of 25 psfCondensation Resistance Factor (CRF): 56 when measured in accordance with AAMA 1503 with clear 1” insulated glass unit (1/4, 1/2, 1/4)Insulation U-Factor: 0.60 BTU/hr/sq ft/degrees F when measured in accordance with AAMA 1503 with clear 1” insulated glass unit (1/4, 1/2,1/4)
● PACKAGING, HANDLING, AND PROTECTION INSTRUCTIONSPackaged in specially designed heavy cartons or shipped pre-fabricated and assembled
● SPECIAL WARRANTYOne (1) year
● LIMITATIONSFraming is limited to applications of one story in heightNot intended for continuous members for multiple floor applications
● SAFETY PRECAUTIONSNormal precautions required
● AVAILABILITYFraming is available in all regions of USA - refer to Internet web site for locations and addresses of distributors
● COSTVaries with elevation, configuration and finish desired
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
THERMAL PRODUCT DESCRIPTION
10
PRODUCT PROPERTIES● MATERIAL, COMPOSITION AND DESIGN
Aluminum: 6063-T6 alloy and temper, to ASTM B221 or ASTM B221MFasteners: Stainless steel, or zinc plated carbon steelPerimeter Anchors: Aluminum, or steel that will be isolated from aluminum componentsGlazing Gaskets: Wedge-type, Ethylene Propylene Diene Monomer (EPDM) rubber with non-stretch cordGlass Stops: Snap-in typeThermal Barrier: Poured and Debridged Polyurethane and Thermal Slots
● SHAPE AND DIMENSIONSFrame Size: 2 x 4-1/2 inchGlass Edge Bite: 3/8 inchGlazing Thickness Accepted: 1/8 inch to 1-1/8 inch in increments of 1/16 inch except 7/16 inch, 9/16 inch, 11/16 inch, and 13/16 inch
● SHOP FABRICATION AND ASSEMBLYProvide for flush glazing on all sides with no projecting stopsConfigurations:■ Two-piece snap together mullions■ Solid tubular mullions, assembled to specially designed shear block clipsAccessories:■ Expansion Mullions■ Corner Mullions■ Open Back Perimeter Members■ Integral Door Frames■ Flashing, Subsills■ Head Receptor■ Heavy Duty Mullions■ Standard Steel Reinforcing
● COLORS AND TEXTURES■ Architectural anodic coating, in accordance with AAMA 611;
o Aluminum Association Designation.□ AA-M10C22A31 - Class II - (Pittco #42 Clear)□ AA-M10C22A41 - Class I - (Pittco #43 Clear)□ AA-M10C22A44 - Class I - (Pittco #59 Champagne)□ AA-M10C22A44 - Class I - (Pittco #60 Light Bronze)□ AA-M10C22A44 - Class I - (Pittco #61 Medium Bronze)□ AA-M10C22A44 - Class I - (Pittco #62 Dark Bronze)□ AA-M10C22A44 - Class I - (Pittco #63 Black)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
THERMALPRODUCT DESCRIPTION
11
■ Architectural organic coating, in accordance with AAMA 2605 (70% Kynar 500®);o Finish on exposed aluminum shall be compliant with the performance standards set forth in AAMA 2605, “Superior Performing Organic
Coatings on Aluminum”.o Type: Factory Applied - High Performance, 70% Polyvinylidene Fluoride (PVDF) coating based on Elf Atochem, Inc. Kynar 500® or
Ausimount USA, Inc. Hylar 5000® resin, formulated by a Licensed Paint Manufacturer and applied by the Paint Manufacturer's WarrantyApproved Applicator.
o Pre-treatment: Applicator to pre-treat the aluminum with solutions to remove Organic and Inorganic Surface Soils and Residual Oxides,followed by a Chrome Phosphate Conversion Coating, at a minimum 40 mg/sq ft to ensure adhesion of paint to aluminum.
o Specify color code, e.g. UC 40577(Duranar Black)
■ Architectural organic coating, in accordance with AAMA 2605 (70% Kynar 500®);o Finish on exposed aluminum shall be compliant with the performance standards set forth in AAMA 2604, “High Performance Organic
Coatings on Aluminum”.o Type: Factory Applied - High Performance, 50% Polyvinylidene Fluoride (PVDF) coating based on Elf Atochem, Inc. Kynar 500® or
Ausimount USA, Inc. Hylar 5000® resin, formulated by a Licensed Paint Manufacturer and applied by the Paint Manufacturer's WarrantyApproved Applicator.
o Pre-treatment: Applicator to pre-treat the aluminum with solutions to remove Organic and Inorganic Surface Soils and Residual Oxides,followed by a Chrome Phosphate Conversion Coating, at a minimum 40 mg/sq ft to ensure adhesion of paint to aluminum.
o Specify color code, e.g. UC 40577(Duranar Black)
PRODUCT PLACEMENT● PREPARATION WORK
Ensure openings are of proper size, and are plumb, square, level and in the proper location and alignment
● INSTALLATIONAlign installed assembly plumb and level, free of warp or twistMaintain dimensional tolerances, aligning with adjacent workSeal joints between framing and building structure watertightFollow guidelines in Pittco Fabrication, Sealant and Erection Brochure
● START-UP AND OPERATIONNot Applicable
● OWNER'S MAINTENANCE INSTRUCTIONSWash surfaces with warm water and mild soap; wipe clean, at least once a year
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
THERMAL PRODUCT DESCRIPTION
12
Corporate IdentificationPittco Architectural Metals, Inc
1530 Landmeier RoadElk Grove Village, Illinois 60007Tel: (847) 593-3131Fax: (847) 593-9946Toll-Free: (800) 992-7488Internet: http://www.pittcometals.comE-mail: [email protected]
Technical Services AvailableToll-Free: (800) 992-7488
Classification and FilingMasterFormat
Subset of Section 08410 - Metal Framed StorefrontsUniFormat
Section B2030 - (exterior entrance frames) or C1020 (interior entrance frames)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
THERMALPRODUCT DESCRIPTION
13
HEAD
HORIZONTAL
GLASS STOP
SILL
GLASS STOP
OPEN BACK MULLION
SNAP-IN FILLER
SCREW SPLINE ASSEMBLY
SHEAR BLOCK ASSEMBLY
HEAD
HORIZONTAL
GLASS STOP
SILL
GLASS STOP
OPEN BACK MULLIONSNAP-IN FILLER
THE SCREW SPLINE SYSTEM ALLOWS A FRAME TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS ARE DRIVENTHROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN THE HORIZONTAL FRAMING MEMBERS. INDIVIDUALUNITS ARE THEN SNAPPED TOGETHER TO FORM A COMPLETE FRAME
THE SHEAR BLOCK METHOD OF FABRICATION IS AN ALTERNATE METHOD OF FABRICATION. HORIZONTALSARE ATTACHED TO THE VERTICAL MULLIONS WITH SHEAR BLOCKS. THIS METHOD MUST BE USED WITHTUBULAR VERTICAL MULLIONS.
SHEAR BLOCK
SHEAR BLOCK
SHEAR BLOCK
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
EXPLODED VIEW
14
3
4
5
1 2
SCREW SPLINE SHEAR BLOCK
2"T
YP
ICA
L
412"
TYPICAL
2"T
YP
ICA
L
412"
TYPICAL
2VERTICAL
1JAMB
3HEAD
4HORIZONTAL
5SILL
2VERTICAL
1JAMB
3HEAD
4HORIZONTAL
5SILL
42-028 (JAMB)20-168 (PERIMETER FILLER)
42-035 (MULLION)42-029 (GLAZING FILLER)
42-028 (JAMB)20-168 (PERIMETER FILLER)
42-035 (MULLION)42-029 (GLAZING FILLER)
42-028 (HEAD)20-168 (PERIMETER FILLER)
42-039 (HORIZONTAL)41-031 (GLASS STOP)
42-030 (SILL)41-031 (GLASS STOP)20-168 (PERIMETER FILLER)20-000 (SUB-SILL)
42-028 (HEAD)20-168 (PERIMETER FILLER)41-034 (SHEAR BLOCK)
42-039 (HORIZONTAL)41-031 (GLASS STOP)41-040 (SHEAR BLOCK)
42-030 (SILL)41-031 (GLASS STOP)20-168 (PERIMETER FILLER)20-000 (SUB-SILL)41-034 (SHEAR BLOCK)
2"TYPICAL
41 2"
TY
PIC
AL
2"TYPICAL
41 2"
TY
PIC
AL
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
NON-THERMALTYPICAL FRAMING DETAILS (Outside Glazed)
D1DETAILS
3
4
5
1 2
SCREW SPLINE SHEAR BLOCK
2"T
YP
ICA
L
412"
TYPICAL
42-060 (HEAD)41-050 (GLASS STOP)20-168 (PERIMETER FILLER)
42-069 (HORIZONTAL)41-050 (GLASS STOP)
42-028 (SILL)20-168 (PERIMETER FILLER)20-000 (SUB-SILL)
2VERTICAL
1JAMB
2VERTICAL
1JAMB
42-028 (JAMB)20-168 (PERIMETER FILLER)
42-035 (MULLION)42-029 (GLAZING FILLER)
42-028 (JAMB)20-168 (PERIMETER FILLER)
42-035 (MULLION)42-029 (GLAZING FILLER)
2"TYPICAL
41 2"
TY
PIC
AL
2"TYPICAL
41 2"
TY
PIC
AL
2"T
YP
ICA
L
412"
TYPICAL
42-060 (HEAD)41-050 (GLASS STOP)20-168 (PERIMETER FILLER)41-041 (SHEAR BLOCK)
42-069 (HORIZONTAL)41-050 (GLASS STOP)41-041 (SHEAR BLOCK)
42-028 (SILL)20-168 (PERIMETER FILLER)41-034 (SHEAR BLOCK)20-000 (SUB-SILL)
3HEAD
4HORIZONTAL
5SILL
3HEAD
4HORIZONTAL
5SILL
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
NON-THERMAL TYPICAL FRAMING DETAILS (Inside Glazed)
D2DETAILS
412"
41 2"
16-705 19-047
2 PIECE NO POCKET CORNER 90° OUTSIDE CORNER
90° INSIDE CORNER ADJUSTABLE MULLION
19-047 42-048
42-049
42-044
42-043
42-14042-141
412" x 41
2" TUBE
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
NON-THERMALCORNER DETAILS
D3DETAILS
19-168
214"
19-102 20-101
19-152
30-105
17-021
30-18430-184
STANDARD MULLION w/OPTIONAL STEEL
EXPANSION MULLION
14" SNAP IN
GLAZING ADAPTER
12" SNAP IN
GLAZING ADAPTER
FULL LENGTHFLAT FILLER
SNAP INPOCKET FILLER
HEAD RECEPTOR OPTIONAL SILL FLASHINGS
NARROW SIDELITE BASE
16-500
42-028
42-029 42-033
42-032
19-04519-183
17-349
16-142
42-139
42-029
HEAVY WALL MULLION
214"
HEAVY WALLEXPANSION MULLION
42-033
42-025
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
NON-THERMAL MISCELLANEOUS DETAILS
D4DETAILS
3
4
5
1 2
SCREW SPLINE SHEAR BLOCK
2VERTICAL
1JAMB
3HEAD
4HORIZONTAL
5SILL
2VERTICAL
1JAMB
3HEAD
4HORIZONTAL
5SILL
41-028 (JAMB)20-168 (PERIMETER FILLER)
41-035 (MULLION)41-029 (GLAZING FILLER)
2"TYPICAL
41 2"
TY
PIC
AL
2"T
YP
ICA
L
412"
TYPICAL
41-028 (HEAD)20-168 (PERIMETER FILLER)
41-039 (HORIZONTAL)41-031 (GLASS STOP)
41-030 (SILL)41-031 (GLASS STOP)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)
2"T
YP
ICA
L
412"
TYPICAL
41-028 (HEAD)20-168 (PERIMETER FILLER)41-034 (SHEAR BLOCK)
41-039 (HORIZONTAL)41-031 (GLASS STOP)41-040 (SHEAR BLOCK)
41-030 (SILL)41-031 (GLASS STOP)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)41-034 (SHEAR BLOCK)
41-028 (JAMB)20-168 (PERIMETER FILLER)
41-035 (MULLION)41-029 (GLAZING FILLER)
2"TYPICAL
41 2"
TY
PIC
AL
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
THERMALTYPICAL FRAMING DETAILS (Outside Glazed)
D5DETAILS
3
4
5
1 2
SCREW SPLINE SHEAR BLOCK
2VERTICAL
1JAMB
2VERTICAL
1JAMB
41-028 (JAMB)20-168 (PERIMETER FILLER)
41-035 (MULLION)41-029 (GLAZING FILLER)
2"TYPICAL
41 2"
TY
PIC
AL
41-028 (JAMB)20-168 (PERIMETER FILLER)
41-035 (MULLION)41-029 (GLAZING FILLER)
2"TYPICAL
41 2"
TY
PIC
AL
3HEAD
4HORIZONTAL
5SILL
3HEAD
4HORIZONTAL
5SILL
2"T
YP
ICA
L
412"
TYPICAL
41-060 (HEAD)41-050 (GLASS STOP)20-168 (PERIMETER FILLER)
41-069 (HORIZONTAL)41-050 (GLASS STOP)
41-028 (SILL)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)
2"T
YP
ICA
L
412"
TYPICAL
41-060 (HEAD)41-050 (GLASS STOP)20-168 (PERIMETER FILLER)41-041(SHEAR BLOCK)
41-069 (HORIZONTAL)41-050 (GLASS STOP)41-041 (SHEAR BLOCK)
41-028 (SILL)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)41-034 (SHEAR BLOCK)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
THERMAL TYPICAL FRAMING DETAILS (Inside Glazed)
D6DETAILS
19-047
2 PIECE NO POCKET CORNER 90° OUTSIDE CORNER
90° INSIDE CORNER ADJUSTABLE MULLION
19-047 41-048
41-049
41-044
41-043
41-14041-141
412"
41 2"
16-705
412" x 41
2" TUBE
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
THERMALCORNER DETAILS
D7DETAILS
19-168
214"
19-102 19-101
STANDARD MULLION w/OPTIONAL STEEL
EXPANSION MULLION
14" SNAP IN
GLAZING ADAPTER
12" SNAP IN
GLAZING ADAPTER
FULL LENGTHFLAT FILLER
SNAP INPOCKET FILLER
HEAD RECEPTOR
16-500
41-028
41-029 41-033
41-032
19-04519-183
17-349
19-152
OPTIONAL SILL FLASHINGS
NARROW SIDELITE BASE
16-142
30-105
17-021
30-18430-184
41-139
41-029
HEAVY WALL MULLION
214"
HEAVY WALLEXPANSION MULLION
41-033
41-025
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
THERMAL MISCELLANEOUS DETAILS
D8DETAILS
2"T
YP
ICA
L
412"
TYPICAL1
TRANSOM HEAD
2DOOR HEAD
3BOTTOMRAIL
41-030 (HEAD)41-031 (GLASS STOP)20-168 (PERIMETER FILLER)
41-036 (TRANSOM HEAD)41-037 (SHEAR BLOCK)
SINGLE ACTING
1
2
3
76
54
10
3
98
DOUBLE ACTING
SINGLE ACTINGDOOR JAMBS
DOUBLE ACTINGDOOR JAMBS
41 2"
TY
PIC
AL
10SINGLE ACTING
HEADER
10DOUBLE ACTING
HEADER
641-036 OR 41-177
(MULLION)
TRANSOM JAMBSTransom area for both double or single acting doors withglass surround. Jambs above transom bar are routed outto accept glass holding insert.
41-036 (TRANSOM HEAD)41-037 (SHEAR BLOCK)
841-177 (MULLION)
941-177 (MULLION)
441-036 (MULLION)
541-036 (MULLION)
741-036 OR 41-177
(MULLION)
12-140 (TRANSOM HEAD)34-969 (SHEAR BLOCK)
12-140 (TRANSOM HEAD)34-969 (SHEAR BLOCK)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
ENTRANCE DETAILS
D9DETAILS
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
BLANK PAGE
D10
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6"
LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)
SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)
42-03542-029
A = 15 PSF (720Pa)B = 20 PSF (960 Pa)C = 25 PSF (1200 Pa)D = 30 PSF (1440 Pa)E = 40 PSF (1920 Pa)
42-03542-029
WITH 16-500 STEEL
VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.
A
B
CD
E
A
B
C
D
E
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
NON-THERMALWINDLOAD CHARTS
S1
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6"
LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)
SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)
42-03242-033
A = 15 PSF (720Pa)B = 20 PSF (960 Pa)C = 25 PSF (1200 Pa)D = 30 PSF (1440 Pa)E = 40 PSF (1920 Pa)
42-13942-029
A
B
CD
E
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
NON-THERMAL WINDLOAD CHARTS
S2
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6"
LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)
SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)
41-03541-029
41-03541-029
WITH 16-500 STEEL
A = 15 PSF (720Pa)B = 20 PSF (960 Pa)C = 25 PSF (1200 Pa)D = 30 PSF (1440 Pa)E = 40 PSF (1920 Pa)
VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.
A
B
CDE
A
B
CD
E
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
THERMALWINDLOAD CHARTS
S3
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6"
LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)
SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)
A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THERMAL BREAK
41-03241-033
A
BC
D
E
A = 15 PSF (720Pa)B = 20 PSF (960 Pa)C = 25 PSF (1200 Pa)D = 30 PSF (1440 Pa)E = 40 PSF (1920 Pa)
41-13941-029
A
BCD
E
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
THERMAL WINDLOAD CHARTS
S4
SYSTEM ANALYSIS CRITERIA:
SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THE THERMAL BREAK THERMAL SECTIONS
HORIZONTAL OR DEADLOAD LIMITATIONS ARE BASED UPON 1/8" MAXIMUM ALLOWABLE DEFLECTION WITH 1" THICK INSULATED GLASS
A = SETTING BLOCKS AT 1/8 POINTSB = SETTING BLOCKS AT 1/4 POINTS
42-039 (HORIZONTAL)41-031 (GLASS STOP)
42-069 (HORIZONTAL)41-050 (GLASS STOP)
41-039 (HORIZONTAL)41-031 (GLASS STOP)
41-069 (HORIZONTAL)41-050 (GLASS STOP)
A
B
A
B
AB AB
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
THERMALDEADLOAD CHARTS
S5
STRUCTURAL PROPERTIES of TMS 114 UF NON-THERMAL FRAMINGPart Number Ix Sx Iy Sy
16-500 (Steel) 1.093 0.547 0.024 0.04216-501 (Steel) 0.649 0.316 0.032 0.076
19-168 0.508 0.243 0.012 0.01542-028 2.798 1.201 0.405 0.31542-029 0.832 0.351 0.033 0.08142-030 2.065 0.833 0.367 0.30342-032 2.443 0.984 0.252 0.21542-033 1.880 0.831 0.126 0.21242-035 2.631 1.112 0.349 0.27342-039 2.362 0.953 0.627 0.57342-060 2.407 0.954 0.182 0.16042-069 2.770 1.162 0.313 0.23642-139 6.681 2.778 0.583 0.48242-140 2.129 0.159 0.845 0.14542-141 1.935 0.073 0.826 0.084
STRUCTURAL PROPERTIES of TMS 114T UF THERMAL BARRIER FRAMINGPart Number Ix Sx Iy Sy
16-500 (Steel) 1.093 0.547 0.024 0.04216-501 (Steel) 0.649 0.316 0.032 0.076
19-168 0.508 0.243 0.012 0.01541-028 2.798 1.201 0.405 0.31541-029 0.832 0.351 0.033 0.08141-030 2.065 0.833 0.367 0.30341-032 2.443 0.984 0.252 0.21541-033 1.880 0.831 0.126 0.21241-035 2.631 1.112 0.349 0.27341-039 2.362 0.953 0.627 0.57341-060 2.407 0.954 0.182 0.16041-069 2.770 1.162 0.313 0.23641-139 6.681 2.778 0.583 0.48241-140 2.129 0.159 0.845 0.14541-141 1.935 0.073 0.826 0.084
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
TMS 114 UF/114T UF
JUNE 2018
SECTION PROPERTIES
S6
www.pittcometals.com
ARCHITECTURAL METALS, INC.
TMS 114 UF/114T UF
JUNE 2018
THERMAL CHARTS
T1FOR INSTRUCTIONS ON HOW TO READ THERMAL CHARTS PLEASE SEE GENERAL SECTION OF THE CATALOG