titanium heat exchanger gimleo · ga 07- cm 14 16.5 2.8 15.88 15.88 15.88 mm 15.88 22 22 12.7 28...

of 4 /4
imleo imleo DO THE BEST FOR YOU FOSHAN SHUNDE GIMLEO HEAT EXCHANGER CO.,LTD 3 Add: No .3.Yuema Road,Ronggui Town,Shunde District,Foshan City,Guangdong,China Postcode: 528303 Tel: 86-757-28378560 Fax: 86-757-28378561 GIMLEO Catalog General - High Efficiency Tube in Shell Heat Exchanger Titanium Heat Exchanger

Author: others

Post on 28-Oct-2020

1 views

Category:

Documents


0 download

Embed Size (px)

TRANSCRIPT

  • imleoimleo

    DO THE BEST FOR YOU

    FOSHAN SHUNDE GIMLEO HEAT EXCHANGER CO.,LTD

    3

    Add: No .3.Yuema Road,Ronggui Town,Shunde

    District,Foshan City,Guangdong,China

    Postcode: 528303

    Tel: 86-757-28378560

    Fax: 86-757-28378561

    GIMLEOCatalog General

    -High Efficiency Tube in Shell Heat Exchanger

    Titanium Heat Exchanger

  • imleoimleo

    DO THE BEST FOR YOU DO THE BEST FOR YOU

    3.6

    the compact helix structure of the coil ensures sufficient heat exchange between the

    gas and water

    ,

    High Efficiency Tube in Shell Heat Exchanger

    Features

    Dimension Data

    High Efficiency Tube in Shell Heat Exchanger

    A

    [Structure A] accumulator included

    Gas connection Gas connection

    Gas connection

    When there is accumulator included, the gas pressure of the heat pump can be reduced

    obviously, thus enhance the heat exchanger efficiency.

    High Efficiency of Heat Exchange

    Using high efficiency rifle tube, heat exchange area is 3.6 times than the smooth type.

    Fins inside & outside tube induce turbulence flow of freon and water, It`s one cause of high efficiency.

    the compact helix structure of the coil ensures sufficient heat exchange between the gas and water

    Safety

    Whole tube inside shell has no internal jionts,that`means no welding bug.

    The Copper is fully shaped and then installed into the shell thus free from curedamage.

    There is not block on water loop and the water flow is smooth, thus keep it free from ice and dirty.

    The drain is on the lowest point of the heat exchanger and easy for drainage in cold season.

    Small volume

    Compact size is helpful to save the space for the heat pump and thus reduce the volume of the unit .

    B

    [Structure B] accumulator excluded

    High Efficiency Tube in Shell Heat Exchanger can be widely used in water-source air

    conditioner ,industry chiller and heat pump.

    Work Condition

    O-50~150 C

    R22 R134a R407c R410a

    ( )

    3.2Mpa

    O-30~90 C

    ( )

    5.2MPaMax. pressure

    Temp. range

    Remarks

    Refrigerant side(outside of tube) Water side (in the tube)

    Keep the water clean, recommend to use filter and clean regularly.

    Corrosion proof material must be used for sea water or salty water.

    When there is ice on the tube, the heat exchanger will be damaged,

    so it is necessary to avoid freezing.

    Nature water, sea water, antifreeze(glycol water)

    Refrigerant type

    1 GB/T19447 ASTM B 359 ASME SB 359

    2 T2/TP2 90/10 BFe10-1-1 BFe30-1-1

    Material

    Heat exchanger Tube

    Shell

    1. Standard applied: GB/T19447, or equal with ASTMB359, ASMESB 359.

    2. Material: Copper T2/TP2, and Nickel-Copper 90/10, copper Bfe 10-1-1, BFe30-1-1 for option.

    High quality steel.

  • DO THE BEST FOR YOU

    High Efficiency Tube in Shell Heat Exchanger

    M N

    L

    H3

    H2

    H H1

    M N

    L

    H2

    H H1

    A -A type- accumulator included

    B -B Type- accumulator excluded

    Gas Nozzle

    Liquid Nozzle

    Gas Nozzle

    Liquid Nozzle

    14kW ......

    For big machine,there are many connecting method :Parallel conection,Three connection,...even Eight connection. We

    offer samples for reference:

    Free connection

    GB056-CM

    Eight connection

    Extendible Use

    L

    mm mm mmModel

    kW kW 3m /h

    H1

    mm

    H2

    mm

    M

    mm

    N

    mmmm

    H3Cooling capacity

    Heating capacity

    Water flow rate Water let

    12

    14.5

    2

    2.4 12.7 22

    19x2

    19x2

    GA05-CM

    GA06-CM

    L

    120

    120

    120

    9.52

    9.52

    9.52

    19

    19

    19

    mm mm mm

    30

    30

    30

    GA01-CM

    GA02-CM

    GA03-CM

    O O O 1 35 C 24 C 12 CO O O 2 7 C 6 C 40 C

    Testing conditionO O O Cooling: Indoor DB/WB at 35 C/24 C, water inlet at 12 C;

    O O O Heating: Indoor DB/WB at 7 C/6 C, water inlet at 40 C.

    12

    14.5

    2

    2.4 22 22

    28

    19x2

    19x2

    25x235 4

    GB05-CM

    GB06-CM

    GB10-CM

    Single coil

    Double coil

    Model

    Dimension

    GA04-CM

    2.5

    3.5

    kW

    5.5

    7.5

    3.5

    4.5

    kW

    7.0

    9.5

    0.6

    0.8

    3m /h

    1.2

    1.6

    H

    mm

    328

    258

    218

    388

    H1

    140

    180

    250

    mm

    310

    H2

    50

    50

    50

    mm

    50 120

    M

    147

    147

    147

    mm

    147

    N

    120

    120

    120

    mm

    120 9.52 19

    220

    265

    220

    265

    475

    308

    55

    55

    55

    55

    63

    55

    150

    150

    150

    150

    160

    150 22 19x2

    160

    160

    160

    160

    210

    160

    187

    187

    187

    187

    238

    187

    H

    mm

    350

    305

    393

    350

    305

    393

    9.5

    12

    9.5

    12

    25

    14 16.5 2.8GA07-CM

    15.88

    15.88

    15.88

    mm

    15.88

    22

    22

    12.7

    28

    12.7

    22

    mm

    H3

    25

    25

    25

    25

    _

    _

    _

    Specification

    Cooling capacity

    Heating capacity

    Water flow rate

    Liquid nozzle Gas nozzle

    Water let

    mm

    Liquid nozzle Gas nozzle

    GA05-CMParallel connection

    DO THE BEST FOR YOU

    Titanium Heat Exchanger

    22 19x216.5 2.8GB07-CM 308 55 150 16018714 22_

    410

  • imleoimleo

    Titanium Heat Exchanger

    imleoimleo

    Drainage

    mm

    12.7x7500

    12.7x9500

    12.7x13500

    16x18000

    2-16x18000

    19x21000

    12.7x5500

    3m /h

    2.2

    3

    10.5

    1.5

    4.5

    15

    7.5

    inch

    1.5

    2

    1.5

    1.5

    1

    1.5

    1

    D

    mm

    160

    200

    250

    200

    250

    250

    160

    HD1

    266

    316

    266

    182

    316

    316

    182

    mm mm

    410

    480

    650

    440

    530

    810

    480

    DO THE BEST FOR YOU DO THE BEST FOR YOU

    A Type B Type

    kW

    5

    7

    10.5

    17

    33

    23

    3.5

    Water outlet

    Refrigerant connection

    Titanium tube

    Shell

    Titanium Heat Exchanger

    Refrigerant connection

    Water inlet

    Water outlet

    D2

    DD1

    H H1

    Water inlet

    Water outlet

    Drainage

    ModelTitanium Heating capacity Water flow Water connection

    1O O O 2 24 C 19 C 27 C

    Dimension

    StructureA B

    Water inlet

    A Type B TypeA B

    Titanium tube

    Shell

    Dimension data

    Remarks: 1. The data listed is suggested data and will

    subject to blueprint.

    2. Heating capacity is measured under DB/WB O O O at 24 C/19 C, and inlet water temp. 27 C.

    O-50~150 C

    R22 R134a R407c R410a

    5.2MPa

    Working condition

    The seamless pure Titanium tube TA1,TA2 is made according to standard GB/T3625-1995; The 5.2 Mpa pressure test

    and precise halogen leaking test is carried out in factory.

    There are three material available for shell: PVC-U PP-R and stainles steel. All the material is in line with

    environmental protection requirement and can be chosen according to working condition and environment.

    o 1. PVC-U Stand with acid or alkali, Strong corrosion proof Suitable to be used under 50 C

    o 2. PP-R: Stand with acid or alkali, Strong corrosion proof Suitable to be used under 70 C

    3. Stainless steel Stand with acid or alkali, corrosion proof based on different types of stainless steel.

    o Suitable to be used under 120 C

    Fixing parts and bolt use stainless steel material.

    Temp. range

    O O0~50 C PVC) 0~70 C PP-R)O-15~120 C stainless steel)

    Nature water, sea water, antifreeze(glycol water)

    Keep the water clean, recommend to use filter and clean regularly.

    When the air temperature is under 0 , please drain out all the water

    to avoid freezing.

    Max. pressure

    Remarks

    Water side (in the shell)

    0.4Mpa default 0.5~1.0Mpa( optional

    Refrigerant type

    H1

    H

    D1

    D

    Water inlet

    Water outlet

    Refrigerant side(in Titanium tube)HT-1

    HT-1.5

    HGT-2

    HT-3

    HT-5

    HT-7

    HT-10

    Heat exchanger coil

    Others

    Titanium heat exchanger use seamless pure Titanium as heat conductor.

    It is popularly used for swimming pool and fish pool water heating, as well as

    temperature adjusting for chemical industrial items due to its super strong

    corrosion proof ability.

    Material and Its Identity

    GB/T3625-1995 TA2 5.2MPa

    PVC-U PP-R

    o 1 PVC-U 50 C

    o 2 PP-R 70 C

    o 3 120 C

    Shell

    Ò³Ãæ 1Ò³Ãæ 2Ò³Ãæ 3Ò³Ãæ 4