titan integrated bed system for long term ... - wound …...the medicaid low air loss bed program...

4
TITAN INTEGRATED BED SYSTEM For Long Term Care TITAN IBS

Upload: others

Post on 05-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TITAN INTEGRATED BED SYSTEM For Long Term ... - Wound …...The Medicaid low air loss bed program requires that residents be on a standard low air loss mattress for at least 30 days

TITAN INTEGRATED BED SYSTEMFor Long Term Care

TIT

AN

IBS

Page 2: TITAN INTEGRATED BED SYSTEM For Long Term ... - Wound …...The Medicaid low air loss bed program requires that residents be on a standard low air loss mattress for at least 30 days

Wound K-Air Management is proud to be a leader in the Medicaid Low Air Loss Bed program. Michigan Medicaid beneficiaries being treated for pressure ulcers who are on, or have been on a low air loss mattress with out significant improvement to their wounds may qualify for a fully in-tegrated, total electric, low bed with a built in true low air loss mattress. This Bed is Provided to qualifying residents at NO COST to long-term care facilities. Wound K-Air Management will work with long term care staff to qualify residents and process the necessary paper work. We take care of the documentation so your staff can focus on delivering quality patient care.

Medicaid residents being treated for multiple stage II, single site stage III, IV, or unstageable pressure ulcers qualify for this program from a clinical perspective. The Medicaid low air loss bed program requires that residents be on a standard low air loss mattress for at least 30 days with-out significant improvement to their wounds. This program is also exteneded to new admissions without needing to meet the 30 day air mattress criteria. Wound K-Air Management will gather the appropriate documentation needed to qualify the resident and have the product scheduled for delivery. The bed can normally be delivered within the same day!

This program allows long term care facilities to reduce rental costs, and/or redistribute equipment to other residents as this product often replaces rented equipment. Wound K-Air Management will inservice staff members so they understand how to safely and properly operate the bed. Our 24hr service line will ensure your questions and concerns are answered around the clock.

The Michigan Medicaid Low Air Loss Bed Program

CPR Valvefor rapid deflation

1-800-990-KAIRwww.woundk-air.com

Page 3: TITAN INTEGRATED BED SYSTEM For Long Term ... - Wound …...The Medicaid low air loss bed program requires that residents be on a standard low air loss mattress for at least 30 days

The TITAN IBS Medicaid Bed & Features

Locking Wheels

CPR Valvefor rapid deflation

POWER: When the unit is plugged in the amber STANDBY light will illuminate. Pressing the POWER button will illuminate the green light and the unit will begin to inflate. The green light must be on when the patient is on the mattress. STATIC: The unit starts in the STATIC mode of operation. This mode delivers constant true low air loss. PULSE: In the PULSE mode of operation the mattress will slightly alternate the pressure in all mattress zones every 30 seconds. AUTO FIRM: Pressing the AUTO FIRM button will provide maximum inflation for a period of 3 minutes providing a uniformly firm surface to assist in nursing care, repositioning and transfers. After 3 minutes the unit will automatically return to its previous comfort setting and mode of operation. COMFORT ADJUST: For maximum pressure redistribution the patient should be immersed into the Patriot LAL surface approximately 40%. This can be approximated by illuminating the appropriate number of Comfort LED indicators by pressing the SOFT and FIRM Keys. One light approximates pressure for a 70-90 lb patient. Each additional light approximates another 20 lbs. The chart below can be used to find patient weight and starting LED Indicators. Every patient is unique in weight distribution. To ensure maximum pressure redistribution after adjusting the Comfort Setting a check can be performed to ensure proper adjustment. To do so place a hand in between the cushions underneath the comforter in the middle of the mattress to ensure that the patient is floating approximately 3-4” off the bed frame and immersed approximately 40% into the mattress.

3”-4” Clearance CPR: To quickly deflate the mattress remove the hose from the control unit and the Orange CPR cap at the head of the mattress. This will rapidly deflate the mattress. KEYPAD LOCKOUT: Holding down the hidden button under the Flag for 3 seconds until the green light illuminates will lock-out the unit to prevent unauthorized adjustments. Press the Flag again and it will unlock the key pad.

The Patriot LAL, is a mattress system that provides true low air loss and pressure relief therapy with pulsation. True low air loss systems have been shown to provide advanced pressure relief while maintaining an ideal microclimate for wound healing.

CONTROL UNIT OPERATION

WEIGHT (lbs) LED Indicators 70-90 1 90-110 2 110-130 3 130-150 4 150-170 5 170-190 6 190-210 7 210-230 8 230-250 9 250-275 10

TITAN IBSMedicaid Low air loss bed

1-800-990-KAIRwww.woundk-air.com

LED Light Display

Full Electric Remote

Low shear, Fluid resistant, Vapor permiable, Quilted cover

HEAD

HI/LOW

TREND

KNEE

20-8” Integrated True Air Loss Bladders

Page 4: TITAN INTEGRATED BED SYSTEM For Long Term ... - Wound …...The Medicaid low air loss bed program requires that residents be on a standard low air loss mattress for at least 30 days

Functionality and Specifications20, 8” Integrated True Air Loss Cells

30” Max Deck Height

7” Lowest Deck Height

84” Sleep Surface

Standard 36”&

Bariatric 42” Width Available

Safety Options Include:

Half Rails

Mobility Enablers

Four Wedge Bolster Cover

600 lb Weight Cap.

200 Liter Per MinuteAir Supply