thromboprophylaxie et biosimilaires - samev-dz.com · michalis lk et al. am heart j 2003; ... dans...
TRANSCRIPT
![Page 1: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/1.jpg)
Thromboprophylaxie et biosimilaires
Pr CHERFI
6ème Congrès National de Médecine Vasculaire23 – 25 Avril 2015, Alger
![Page 2: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/2.jpg)
La thromboprophylaxie veineuse
Fin années 80 : premières études
Depuis : plusieurs centaines de millions de patients traités par HBPM
Plusieurs indications : large supériorité des HBPM /HNF
![Page 3: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/3.jpg)
La thromboprophylaxie veineuse
Large efficacité Grande sécurité
![Page 4: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/4.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 5: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/5.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
53% de réduction par
rapport au placebo
![Page 6: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/6.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 7: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/7.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 8: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/8.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 9: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/9.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 10: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/10.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 11: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/11.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 12: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/12.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 13: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/13.jpg)
![Page 14: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/14.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 15: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/15.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
Enoxaparine HNF IV
Hémorragies 2% 1.2 % p=0,05
Thrombocytopénie 2% 2 %
![Page 16: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/16.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
Warfarine Enoxaparine
-Evenement grave (récidive
TVP ou hémorragie 21% 10% p=0,04
- Décès 22.7% 11.3% p=0.07
- Décès par hémorragie 6cas 0 cas
![Page 17: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/17.jpg)
1988
PLANES
1996
BERGQVIST
2002SAMAMA
2003
ZUFFEREY
1993
HASS
2001
MISMITTY
1998
AGNELLI
2002
ENOXACAN
1999
MEDENOX
1993
SIMONNEAU
1996
LEVINE
2011
SFAR
2007
ENDORSE1991
WINDSOR
![Page 18: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/18.jpg)
La thromboprophylaxie veineuse
Multiplicité des moyens
HBPM
EnoxaparineDalteparine
Nadroparine
Tinzaparine
Bemiparine
![Page 19: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/19.jpg)
La thromboprophylaxie veineuse
Multiplicité des moyens
2000
2500
4000
3500
4500
5000
1900
2850
3800
6000
5700
8000
10.000
14.000
18.000
![Page 20: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/20.jpg)
La thromboprophylaxie veineuse
Multiplicité des moyens
2000
2500
4000
3500
4500
5000
1900
2850
3800
6000
5700
8000
10.000
14.000
18.000
0.2ml
O.3ml 0.4ml
0.5ml
0.6ml
0.8ml
1ml
![Page 21: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/21.jpg)
La thromboprophylaxie veineuse
Multiplicité des moyens
HNF HBPM
AODMoyens
physiques
EnoxaparineDalteparine
Nadroparine
Tinzaparine
Bemiparine
Unités
mgml
1850
2000
2500
4000
50000.2ml
O.3ml 0.4ml
0.25
0.5ml
![Page 22: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/22.jpg)
Très large utilisation
Presque 30 ans d’utilisation
Plusieurs centaines de millions de patients traités
NB: - Besoins en 2009 : 620 Millions de porcs, soit 1 porc – 1 seringue- En France (2011): 1.7 Millions de personnes traités par HBPM (Assurances)
![Page 23: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/23.jpg)
![Page 24: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/24.jpg)
La connaissance parfaite de la molécule et
l’Expertise clinique sont indispensables
![Page 25: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/25.jpg)
Comment appréhender les BIOSIMILAIRES ?
![Page 26: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/26.jpg)
Evolution du marché mondial des biomédicaments
![Page 27: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/27.jpg)
Problème de définition
![Page 28: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/28.jpg)
GENERIQUE OU BIOSIMILAIRE?
Nandurkar et al Intern Med J 2014, 44: 497-
GENERIQUE BIOSIMILAIRE
Produit par synthèse chimique Produit de source biologique issue du
vivant
Petit PM 100 à 1000 Da PM élevé > 1000 Da
Structure définie et bien caractérisée
aisé à reproduire à l’identique
Structure complexe
Non intégralement caractérisée
(HBPM)
Difficile à reproduire à l’identique
Structure indépendante du procédé de
fabrication
Structure dépendante du procédé de
fabrication
Pureté et grande stabilité Contaminants et impuretés possibles
Qualité et stabilité délicate
Pas d’immunogénicité Immunogénicité potentielle
Bioéquivalence facile à démontrer Bioéquivalence compliquée à
démonter (programme de
comparabilité)
![Page 29: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/29.jpg)
Définition d’un médicament biologique
• Substance produite ou extraite à partir d’une source biologique et qui
nécessite pour sa caractérisation et l’établissement de sa qualité une
combinaison de tests physico-chimiques et biologiques.
• Produits complexes: pas exactement identique à l’original mais il aurait un
haut degré de similarité et il serait utilisable à la même dose et dans les
mêmes indications que le produit de référence. Une série bien plus complexe
d’étapes est requise pour démontrer cette « biosimilarité »
• Difficiles à caractériser avec les méthodes analytiques usuelles ou de routine
(activité biologique)
• La qualité du produit dépend fortement du processus de fabrication :
la composition peut varier d’une préparation à l’autre
le changement du processus de fabrication entraîne des changements
importants dans la sécurité / efficacité.
• Immunogénicité liée à un changement de structure
![Page 30: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/30.jpg)
Définition d’un médicament biologique
• Substance produite ou extraite à partir d’une source biologique et qui
nécessite pour sa caractérisation et l’établissement de sa qualité une
combinaison de tests physico-chimiques et biologiques.
• Produits complexes: pas exactement identique à l’original mais il aurait un
haut degré de similarité et il serait utilisable à la même dose et dans les
mêmes indications que le produit de référence. Une série bien plus complexe
d’étapes est requise pour démontrer cette « biosimilarité »
• Difficiles à caractériser avec les méthodes analytiques usuelles ou de routine
(activité biologique)
• La qualité du produit dépend fortement du processus de fabrication :
la composition peut varier d’une préparation à l’autre
le changement du processus de fabrication entraîne des changements
importants dans la sécurité / efficacité.
• Immunogénicité liée à un changement de structure
![Page 31: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/31.jpg)
![Page 32: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/32.jpg)
Y a-t-il une particularité des ‘’HBPM’’ ?
![Page 33: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/33.jpg)
Copies connues des HBPM
Simoens et Huys, Sem Thromb Haemost 2013, 39: 250-257
![Page 34: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/34.jpg)
Les HBPM sont produites par dépolymérisation
Héparine non fractionnée
Dépolymérisation oxydative
Clivage par désamination avec le nitrate d’isoamyle
Clivage par β-élimination par traitement alcalin
Clivage par désamination avec l’acide nitreux
Clivage par β-élimination avec l’héparinase
Adéparine
PamaparineCertoparine
Enoxaparine
Daltéparine
NadroparineTinzaparine
Fareed J et al. Are the Available Low-Molecular-WeightnHeparin Preparations the Same? Seminars in thrombosis and hemostasis 1996; 22 (S1):77-91
Les HBPM qui en résultent sont un ensemble complexe de sucres hétérogènes
Les HBPM sont préparées à partir d'HNF par divers procédés de
dépolymérisation chimique ou enzymatique
![Page 35: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/35.jpg)
La dépolymérisation
L adépolymérisation n’affecte pas seulement le PM mais aussi :
- La structure, la localisation et la distribution des séquences pentasaccharidiques (sites de liaison de l’AT), responsable de l’activité anticoagulante
- Le rapport anti-Xa/anti-IIa
![Page 36: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/36.jpg)
Structure fonctionnelle de l’héparine(sites variable de localisation du pentasaccharide)
(sites variable de localisation du pentasaccharide)
![Page 37: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/37.jpg)
HÉTÉROGÉNÉITÉ DES HBPM
European Pharmacopoeia 2010
Héparines PM moyen(Da)
Anti-Xa/anti-IIa
Anti-Xa/mg
HNF 15000 1 193 UI
Tinzaparine 6500 1.8 90 IU
Dalteparine 6000 2.5 160 IU
Enoxaparine 4500 3.6 100 IU
Nadroparine 4300 3.2 95–130 IU
Reviparine 3800 3.25 106 IU
Bemiparine 3600 9 80 IU
Keire DA and al. Caracterisation of currently marketed heparin products: Key tests for quality assurance. Anal Bioanal Chem 2011; 399:581-591
![Page 38: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/38.jpg)
Indication enoxaparin nadroparin tinzaparin dalteparin bemiparin reviparin
General
surgery P P P P P P
Major
orthopedic
surgeryP P P P P P
Medical
patients P - - P - -Unstable
angina,
Non Q AMIP - - - - -
Treatment
of VTE P P P P P P
Hemofil-
tration P P P P P P
Prévention
de la MTEV
SCA
traitement
MTEV
traitement
FDA & EMA : HBPM et AMM
![Page 39: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/39.jpg)
30% des chaines (PS) sont anticoagulantes mais…
les 70% restant sont-elles dénuées d’effet?
Adapted from Lovenox
pharmacopeia
30%
Anticoagulan
t
70%
Non-
anticoagula
nt?
Clinical ImpactPharmacological
Activities
![Page 40: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/40.jpg)
30% des chaines (PS) sont anticoagulantes mais…
les 70% restant sont-elles dénuées d’effet?
Adapted from Lovenox
pharmacopeia
30%
Anticoagulant
70%
Non-
anticoagula
nt?
Clinical ImpactPharmacological
Activities
Activités anti-Xa et anti-IIa (penta-saccharide-AT) : 15 à 25%
75 à 85% des chaines restantes :
-Activités connues :Inhibition facteur tissulaire (TFPI); diminution facteur Willebrand circulant; action anti-inflammatoire;profibrinolytique; antiprolifératif (anti-tumoral)
- Activités non connues : 30%
![Page 41: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/41.jpg)
HBPM : COMPLEXITE ET DIVERSITE
![Page 42: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/42.jpg)
7,5 mg/24h* TVP, EPArixtra®
171 UI/kg/24hTVPFraxodi®
Schémas à 1 seule injection SC par jour
85 UI/kg/12hTVP, EPFraxiparine®
100 UI/kg/12hTVP±EP, SCALovenox®
120 UI/kg/12hTVP, EPFragmine®
Schémas à 2 injections SC par jour
PosologieIndicationsHBPM
Angor : angor instable en phase aiguë sans onde Q
* Si patient entre 50 et 100 kg, 5 mg si < 50 kg, 10 mg si > 100 kg
175 UI/kg/24hTVP, EPInnohep®
HBPM : TRAITEMENTS CURATIFS
![Page 43: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/43.jpg)
20,1%
10,5%
21,7%
9,5%
0%
5%
10%
15%
20%
25%
All DVT Proximal DVT
Enoxaparin (N=219)
Tinzaparin (N=221)
Chirurgie Orthopédique :
Pas de Différence entre 2 HBPMD
VT
in
cid
en
ce
(%
)
Planes A et al. Thromb Haemost 1999; 81: 22–5
Bleeding Events
Pre- and postoperatively, no difference was observed between the two groups as regards immediate bleeding
tendency, assessed by the total blood loss in the two groups. Homologous blood requirements were similar in both
groups. All major bleeds were observed at the wound site
Enoxaparin 4000 IU anti-Xa versus tinzaparin 4500 IU anti-Xain Major Orthopedic Surgery
![Page 44: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/44.jpg)
12,3%
17,7%
25,5%21,2%
28,0%
44,0%
0%
10%
20%
30%
40%
50%
Day 7 Day 30 Month 6
Enoxaparin Tinzaparin
Tri
ple
co
mp
osit
e e
nd
po
int
(%)
Michalis LK et al. Am Heart J 2003;146:304–10
Katsouras C et al. Am Heart J 2005;150:385–91
P=0.015
P=0.012
P<0.001
Bleeding Events
Day 7 : No difference was found in the rate of serious hemorrhagic complications between the enoxaparin group
(3.6%) and the tinzaparin group (3.2%). Serious hemorrhagic complications related to revascularization
procedures occurred in 1 patient in the enoxaparin group and in 2 patients in the tinzaparin group
Composite Efficacy Endpoint
Death, MI, and Recurrent Angina
Enoxaparine versus Tinzaparine
dans le SCA non STEMI
Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-XaQD in Unstable Angina / NSTE-MI (EVET study)
![Page 45: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/45.jpg)
HBPM : COMPLEXITE ET DIVERSITE
PAS D’INTERCHANGEANBILITE
![Page 46: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/46.jpg)
Interchangeabilité des HBPM
46
![Page 47: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/47.jpg)
Ressemblance et Dissemblance
![Page 48: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/48.jpg)
La reproduction exacte du médicament ‘’ Vivant’’ est techniquement impossible: Nous parlons donc de BIOSIMILAIRE et
non de BIOGENERIQUE
![Page 49: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/49.jpg)
La reproduction exacte du médicament ‘’ Vivant’’ est techniquement impossible: Nous parlons donc de BIOSIMILAIRE et
non de BIOGENERIQUE
Similaire ≠ Identique
![Page 50: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/50.jpg)
La reproduction exacte du médicament ‘’ Vivant’’ est techniquement impossible: Nous parlons donc de BIOSIMILAIRE et
non de BIOGENERIQUE
L’Homologation doit donc être donné sur la base d’une équivalence de résultats thérapeutiques (études cliniques) et non pas seulement sur la
base d’une équivalence pharmaceutique (cas des produits chimiques)
Similaire ≠ Identique
![Page 51: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/51.jpg)
Mesure de l’activité anti-Xa de l’enoxaprine et de ses copies
Gerotziafas et al poster 3334, 52nd ASH meeting Orlando 2010
![Page 52: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/52.jpg)
Lovenox (3425 Da)
Enoxaparin (3694 Da)
Cutenox (3746 Da)
Dilutol (3976 Da)
Dalteparin (6281 Da)
Tinzaparin (6038 Da)
AU
0.00
0.02
0.04
0.06
0.08
0.10
0.12
0.14
Minutes32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49
Aug.05ISTHPoster
Differential Digestion of LMWHs by Heparinase-II: Drug
Development Implications
W.P.Jeske
J. Maddineni
Différences dans la distribution des poids moléculaires au sein des copies et par rapport au modèle par l’analyse en chromatographie
![Page 53: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/53.jpg)
Procédé de Fabrication d’Enoxaparine
![Page 54: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/54.jpg)
W.P.Jeske, J.Walenga. Pharmacodynamic Differentiation of Generic Low Molecular Weight Heparins. Abstract & Poster #75. ASH, Dec 2007.
Différences détectées dans un Modèle de saignement chez l’animal pour diverses copies.
Modèle de saignement : oreille du lapin
Le modèle de saignement de l'oreille du
lapin a été réalisé conformément à la
publication de Cade, J.F. et al (Thromb.
Res. 35:613-25, 1984.) Chaque HBPM a
été administrée en bolus IV de 5 mg/kg.
Après un temps de circulation de 15
minutes, la perte sanguine a été mesurée
sur une période de 10 minutes.
![Page 55: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/55.jpg)
Quels en sont les risques ?
Efficacité et tolérance différentes ?
![Page 56: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/56.jpg)
Critères de comparaison?
Critères simplifiés Critères peu discriminatifs
![Page 57: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/57.jpg)
Critères de comparaison?
Critères simplifiés Critères peu discriminatif
‘’L’absence de preuves n’est pas la preuve de l’absence de différence’’ L. Drouet 2011
![Page 58: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/58.jpg)
Harenberg J et al J Thromb Haemost 2013; 11: 1421–5.
![Page 59: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/59.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHYSICO-CHIMIQUE
Origine matière première connue, spécifiée et identique
Caractérisation physico-chimique par chromatographie d’affinité sur
AT, digestion sélective par héparinase, analyse par RMN, HPLC
combinée à ESI-MS
Analyse des variation inter-lots avec seuils définis
Divers Essais expérimentaux de similarité « tous tests avec
dispersion statistique »
Même ratio de disaccharides et recomposition des oligosaccharides
identique
Vérifier absence d’autres oligosaccharides ou impuretés par RMN
![Page 60: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/60.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHYSICO-CHIMIQUE
Origine matière première connue, spécifiée et identique
Caractérisation physico-chimique par chromatographie d’affinité sur
AT, digestion sélective par héparinase, analyse par RMN, HPLC
combinée à ESI-MS
Analyse des variation inter-lots avec seuils définis
Divers Essais expérimentaux de similarité « tous tests avec
dispersion statistique »
Même ratio de disaccharides et recomposition des oligosaccharides
identique
Vérifier absence d’autres oligosaccharides ou impuretés par RMN
![Page 61: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/61.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHYSICO-CHIMIQUE
Origine matière première connue, spécifiée et identique
Caractérisation physico-chimique par chromatographie d’affinité sur
AT, digestion sélective par héparinase, analyse par RMN, HPLC
combinée à ESI-MS
Analyse des variation inter-lots avec seuils définis
Divers Essais expérimentaux de similarité « tous tests avec
dispersion statistique »
Même ratio de disaccharides et recomposition des oligosaccharides
identique
Vérifier absence d’autres oligosaccharides ou impuretés par RMN
![Page 62: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/62.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHYSICO-CHIMIQUE
Origine matière première connue, spécifiée et identique
Caractérisation physico-chimique par chromatographie d’affinité sur
AT, digestion sélective par héparinase, analyse par RMN, HPLC
combinée à ESI-MS
Analyse des variation inter-lots avec seuils définis
Divers Essais expérimentaux de similarité « tous tests avec
dispersion statistique »
Même ratio de disaccharides et recomposition des
oligosaccharides identique
Vérifier absence d’autres oligosaccharides ou impuretés par RMN
![Page 63: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/63.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHYSICO-CHIMIQUE
Origine matière première connue, spécifiée et identique
Caractérisation physico-chimique par chromatographie d’affinité sur
AT, digestion sélective par héparinase, analyse par RMN, HPLC
combinée à ESI-MS
Analyse des variation inter-lots avec seuils définis
Divers Essais expérimentaux de similarité « tous tests avec
dispersion statistique »
Même ratio de disaccharides et recomposition des oligosaccharides
identique
Vérifier absence d’autres oligosaccharides ou impuretés par RMN
![Page 64: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/64.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHARMACOLOGIQUE
Mêmes activités Anti-Xa, Anti-IIa, inhibition de la génération de thrombine,
libération de FT in vitro et ex vivo, neutralisation par protamine,
interactions in vitro avec Ac TIH et tests d’immunogénicité (≥ 5 lots ≠).
Etudes de toxicité sur ≥ 2 modèles animaux et absence de ≠ sur modèles
expérimentaux standard de thrombose veineuse/artérielle et d’hémorragie.
Etudes de Phase I chez volontaires sains avec doses prophylactiques et
curatives (pdt 5 à 7 jours chacune)
En cas de différences observées lors des étapes antérieures, une étude
chirurgicale sur la MTEV post-opératoire et une étude cardiologique
préférentiellement dans l’angor instable sont requises
En cas d’AMM, mise en place d’un Plan de Gestion des Risques rigoureux et
prolongé avec suivi de pharmacovigilance collaboratif (FDA ou EMEA)
![Page 65: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/65.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHARMACOLOGIQUE
Mêmes activités Anti-Xa, Anti-IIa, inhibition de la génération de thrombine,
libération de FT in vitro et ex vivo, neutralisation par protamine, interactions in
vitro avec Ac TIH et tests d’immunogénicité (≥ 5 lots ≠).
Etudes de toxicité sur ≥ 2 modèles animaux et absence de ≠ sur modèles
expérimentaux standard de thrombose veineuse/artérielle et d’hémorragie.
Etudes de Phase I chez volontaires sains avec doses prophylactiques et
curatives (pdt 5 à 7 jours chacune)
En cas de différences observées lors des étapes antérieures, une étude
chirurgicale sur la MTEV post-opératoire et une étude cardiologique
préférentiellement dans l’angor instable sont requises
En cas d’AMM, mise en place d’un Plan de Gestion des Risques rigoureux et
prolongé avec suivi de pharmacovigilance collaboratif (FDA ou EMEA)
![Page 66: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/66.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHARMACOLOGIQUE
Mêmes activités Anti-Xa, Anti-IIa, inhibition de la génération de thrombine,
libération de FT in vitro et ex vivo, neutralisation par protamine, interactions in
vitro avec Ac TIH et tests d’immunogénicité (≥ 5 lots ≠).
Etudes de toxicité sur ≥ 2 modèles animaux et absence de ≠ sur modèles
expérimentaux standard de thrombose veineuse/artérielle et d’hémorragie.
Etudes de Phase I chez volontaires sains avec doses prophylactiques et
curatives (pdt 5 à 7 jours chacune)
En cas de différences observées lors des étapes antérieures, une étude
chirurgicale sur la MTEV post-opératoire et une étude cardiologique
préférentiellement dans l’angor instable sont requises
En cas d’AMM, mise en place d’un Plan de Gestion des Risques rigoureux et
prolongé avec suivi de pharmacovigilance collaboratif (FDA ou EMEA)
![Page 67: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/67.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHARMACOLOGIQUE
Mêmes activités Anti-Xa, Anti-IIa, inhibition de la génération de thrombine,
libération de FT in vitro et ex vivo, neutralisation par protamine, interactions in
vitro avec Ac TIH et tests d’immunogénicité (≥ 5 lots ≠).
Etudes de toxicité sur ≥ 2 modèles animaux et absence de ≠ sur modèles
expérimentaux standard de thrombose veineuse/artérielle et d’hémorragie.
Etudes de Phase I chez volontaires sains avec doses prophylactiques et
curatives (pdt 5 à 7 jours chacune)
En cas de différences observées lors des étapes antérieures, une étude
chirurgicale sur la MTEV post-opératoire et une étude cardiologique
préférentiellement dans l’angor instable sont requises
En cas d’AMM, mise en place d’un Plan de Gestion des Risques rigoureux et
prolongé avec suivi de pharmacovigilance collaboratif (FDA ou EMEA)
![Page 68: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/68.jpg)
RECOMMANDATIONS POUR LA
COMPARAISON DE BIOSIMILARITÉ PHARMACOLOGIQUE
Mêmes activités Anti-Xa, Anti-IIa, inhibition de la génération de thrombine,
libération de FT in vitro et ex vivo, neutralisation par protamine, interactions in
vitro avec Ac TIH et tests d’immunogénicité (≥ 5 lots ≠).
Etudes de toxicité sur ≥ 2 modèles animaux et absence de ≠ sur modèles
expérimentaux standard de thrombose veineuse/artérielle et d’hémorragie.
Etudes de Phase I chez volontaires sains avec doses prophylactiques et
curatives (pdt 5 à 7 jours chacune)
En cas de différences observées lors des étapes antérieures, une étude
chirurgicale sur la MTEV post-opératoire et une étude cardiologique
préférentiellement dans l’angor instable sont requises
En cas d’AMM, mise en place d’un Plan de Gestion des Risques rigoureux
et prolongé avec suivi de pharmacovigilance collaboratif (FDA ou EMEA)
![Page 69: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/69.jpg)
En Pratique: un cadre bien défini
69
![Page 70: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/70.jpg)
Guide UE sur HBPM biosimilaire
70
Études non cliniques(Études pharmacodynamiques comparatives )
1 - Études in vitroActivité anti-FXaActivité anti-FIIa
2 - Études in vivo"suitable animal venous" or "arterial thrombosis model"
(rats ou lapins, primate non-humain)Comparaison des activités anti-FXa, anti-FIIa et libération du TFPI
3 - Études toxicologiques de sécurité et de reproduction non requises.Éventuellement tolérance locale.
![Page 71: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/71.jpg)
1 - Activités anti-FXa et anti-FIIa comme "surrogate markers" des concentrations circulantes.
• Chez volontaires sains à dose unique en crossover (sc et/ou iv)
• Marges d'équivalence pré-spécifiées et justifiées
71
Guide UE sur HBPM biosimilaire
Études cliniques
![Page 72: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/72.jpg)
• Essai randomisé, double aveugle, en groupe parallèle
• Cadre : prévention thromboses veineuses ou artériels ou traitements des thromboses veineuses
• Patients de chirurgie à haute prévalence (hanche ou genou)
• "Composite Endpoint" : nombre total d'évènements thromboemboliques
– total DVTs (+ asymptomatic distal),
– PE and VTE-related death
• Suivi sur 60 jours pour événement tardifs
72
Guide UE sur HBPM biosimilaire
Études cliniques (Efficacité clinique)
![Page 73: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/73.jpg)
1 - Type, fréquence et sévérité des effets secondaires
- Saignements majeurs
- Saignements non majeurs cliniquement pertinents
(évaluation centralisé en aveugle par comité d'experts)
-Tests fonction hépatique
2 - Comparaison de l'immunogénicité (référence versus copie)
- Immédiate TIH type II (plaquettes et PF4-Heparin complexAb)
- Suivi en PGR car TIH type II < 0,1%
Alger 2014 73
Guide UE sur HBPM biosimilaire
Études cliniques(Comparaison des profils de sécurité entre référence et copie)
![Page 74: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/74.jpg)
1 - Suivi de pharmacovigilance
• PSUR + PGR (plan de gestion des risques)
– Suivi en PGR
» HIT II car fréquence faible (< 0,1%)
» Réactions anaphylactoïdes et anaphylactiques
2 - Extrapolation des indications
• Si comparabilité efficacité et sécurité démontrée chez patients chirurgicaux à haut risque de VTE
• Possibilité d'extrapolation aux autres indications du produit de référence (avec justification par le demandeur)
Alger 2014 74
Guide UE sur HBPM biosimilaire
Études cliniques (Suivi)
![Page 75: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/75.jpg)
- Des études pharmacodynamiques- Des études toxicologiques- Des études cliniques d’efficacité et de tolérance- Un suivi de sécurité des patients et un plan de gestion des risques (PGR)
FDA :
Equivalence des propriétés physico-chimiquesEquivalence de l’origine de la matière première et de la méthode de dépolymérisationEquivalence de la structure et de la séquence oligosaccharidiqueEquivalence des tests biochimiques et biologiquesEquivalence du profil pharmacodynamique in vivo
EMEA : a. Etudes non cliniques :
- pharmacodynamie comparative in vitro (anti-Xa /anti-IIa)- modèles animaux veineux et/ou artériels (anti-Xa/anti-IIa et TFPI)
b. Etudes cliniques :- étude pharmacodynamique (anti-Xa/anti-IIa et libération TFPI)- volontaires sains en cross-over - efficacité randomisé double aveugle en parallèle (TVP, prvention, TART, orthopédie…etc.)- sécurité clinique (effets secondaires, hémorragies, immunogénicité)- suivi de pharmacovigilance (PGR+++)
![Page 76: Thromboprophylaxie et biosimilaires - samev-dz.com · Michalis LK et al. Am Heart J 2003; ... dans le SCA non STEMI Enoxaparin 100 IU anti-Xa/Kg BID versus tinzaparin 175 IU anti-Xa](https://reader031.vdocuments.mx/reader031/viewer/2022013018/5cebee5688c99319498c3bb2/html5/thumbnails/76.jpg)
► HBPM : produits biologiques de structure encore non complètement caractérisée
► HBPM agents multi-cibles aux actions anti-coagulantes et non-anticoagulantes
►Production d’HBPM est issue d'un procédé de fabrication complexe et unique
à chaque fabriquant, contrôlé au plan qualité et reproductibilité aboutissant
à un mélange unique d’oligosaccharides de structure spécifique aux actions
pharmacologiques démontrées,
Conclusion
La Biosimilarité doit être démontrée à travers une exacte similitude par toute
une série d’essais analytiques précliniques et cliniques associées à un plan
de Gestion des risques (PGR) pour la surveillance des effets adverses dans
la vraie vie
A la lumière de ces données et compte tenu des standards scientifiques et
reglémentaires, la biosimilarité d’une HBPM ne se limite pas à la simple
comparaison des poids moléculaires, de l’activité anti-Xa et du ratio
anti-Xa/anti-IIa.