three phase volt meter · three phase volt meter ev 93 1 features: auto ranging. connection diagram...

2
Supply Voltage Auxiliary Supply 80V to 270V AC Frequency 50/60 Hz Display 4 digits 7 segment LED display Digit Height 0.56” (14.3mm) Display Range 0 to 516.0 VAC Display Input Specifications Input Voltage Range System P. T. Ratio 11 to 300V AC (L-N) 19 to 516V AC (L-L) 3Ø4W, 3Ø3W & 1Ø2W PTR Site Selectable Class 0.5 Accuracy Resolution Auto ranging Update Time 1 Sec. Temperature Operating : -10° to 55°C Storage : -20° to 75°C Humidity < 95% RH Environmental Specifications Mounting Flush Mounting with Side Clamps Weight 180 g Enclosure Material ABS Thermoplastic Mechanical Specifications Dimension 96 46 96 92 92 Tolerance: 92 x 92 -2 +0 -2 +0 Panel Cutout Side View Front View Radio Interference Suppression CISPR22 Fast Transient Burst Test IEC61000-4.4 Damped Oscillatory Waves Immunity Test IEC61000-4.12 Test of Immunity to Electromagnetic RF Fields IEC61000-4.3 Test of Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields IEC61000-4.6 Test of Immunity to Electrostatic Discharges IEC61000-4.2 Surge Immunity Test IEC61000-4.5 Test of Protection Against Penetration of Dust & Water IEC60529 Applicable Standards Certifications RoHS Three Phase Volt Meter EV 93 www.enzaelectric.com 1 Features: Auto Ranging

Upload: others

Post on 03-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Three Phase Volt Meter · Three Phase Volt Meter EV 93 1 Features: Auto Ranging. Connection Diagram Ordering Code Description Ordering Information EV-93 Three Phase AC Voltmeter (96

Supply Voltage

Auxiliary Supply 80V to 270V AC

Frequency 50/60 Hz

Display 4 digits 7 segment LED display

Digit Height 0.56” (14.3mm)

Display Range 0 to 516.0 VAC

Display

Input Specifications

Input Voltage Range

System

P. T. Ratio

11 to 300V AC (L-N) 19 to 516V AC (L-L)

3Ø4W, 3Ø3W & 1Ø2W

PTR Site Selectable

Class 0.5Accuracy

Resolution Auto ranging

Update Time 1 Sec.

Temperature Operating : -10° to 55°C

Storage : -20° to 75°C

Humidity < 95% RH

Environmental Specifications

Mounting Flush Mounting with Side Clamps

Weight 180 g

Enclosure Material ABS Thermoplastic

Mechanical Specifications

Dimension

96

46

96

92

92

Tolerance: 92 x 92-2

+0

-2

+0

Panel CutoutSide ViewFront View

Radio Interference Suppression

CISPR22

Fast Transient Burst Test IEC61000-4.4

Damped Oscillatory Waves Immunity Test

IEC61000-4.12

Test of Immunity to Electromagnetic RF Fields

IEC61000-4.3

Test of Immunity to ConductedDisturbances, Induced by Radio-Frequency Fields

IEC61000-4.6

Test of Immunity to Electrostatic Discharges

IEC61000-4.2

Surge Immunity Test IEC61000-4.5

Test of Protection Against Penetration of Dust & Water

IEC60529

Applicable Standards

Certifications

RoHS

Three Phase Volt Meter

EV 93

www.enzaelectric.com 1

Features:

Auto Ranging

Page 2: Three Phase Volt Meter · Three Phase Volt Meter EV 93 1 Features: Auto Ranging. Connection Diagram Ordering Code Description Ordering Information EV-93 Three Phase AC Voltmeter (96

Connection Diagram

Ordering Code Description

Ordering Information

EV-93 Three Phase AC Voltmeter (96 x 96)

R Y B N

LOAD

Source

P N

Fuse **

www.enzaelectric.com

PT. PRIPT Ratio Table

415V 415V 1.00415V 110V

110V110V110V110V110V110V110V110V

3.7727440V 4.002.2kV 20.03.3kV 30.06.6kV 60.011kV 10022kV 20033kV 30066kV 600

PT. SEC PTR

Connection Scheme

Accuracy : Class 0.5U1 to U4 Voltage Input: 25V to 500V ACPT Ratio : PTR SelectableAux Supply : 80V to 260V AC

Model : EV 93

U1

U2

U3

U4

23

21

19

18

P

N

10

11A

ux

. Su

pp

ly8

0 to

27

0V

AC

EV 93Three Phase Volt Meter

www.enzaelectric.com 2