this site · 2017. 6. 20. · note: sign and seal of electrical plans is the sole authority of a...
TRANSCRIPT
A-1
SHEET NO.SUBMITTED BY:
APPROVED BY:
RECOMMEND APPROVAL:
CHECKED BY:PREPARED BY:PROJECT TITLE:
LOCATION: LOCATION:
Republic of the Philippines
NATIONAL POLICE COMMISSION
PHILIPPINE NATIONAL POLICE
Camp Quintin M Merecido, Davao City
Kidalapong, Malita, Davao Occidental
PROPOSED PROVINCIAL HEADQUARTERS SUPPORT GROUP
ENGINEERING SERVICE
REGIONAL PROJECT MANAGEMENT UNIT 11
Director, ES
Police Chief Superintendent
PHILIP LAWRENCE S ABAPO, III
POLICE SENIOR INSPECTOR
ANTONIO A TAYLAN, JR
Asst. Chief, RPMU
MARIA DEOVINA G SEVILLANO
Police Chief Inspector
Acting Chief, RPMU
ABELARDO C MATILLANO
Police Senior Superintendent
Chief of Staff, ES
MANUEL G FABROS
Police Senior Superintendent
Deputy Director, ES
DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE
Acting Chief, ID, ES
HONORIO R AGNILA
Police Superintendent
P
D
's
Q
U
A
R
T
E
R
S
C
H
A
P
E
L
E
N
T
R
A
N
C
E
G
A
T
E
O
U
T
P
O
S
T
P
O
W
E
R
M
O
T
O
R
P
O
O
L
O
U
T
P
O
S
T
F
L
A
G
P
O
L
E
S
E
C
U
R
IT
Y
S
E
C
U
R
IT
Y
O
U
T
P
O
S
T
S
E
C
U
R
I
T
Y
P
A
R
A
D
E
G
R
O
U
N
D
G
R
A
N
D
S
T
A
N
D
P
P
S
C
B
U
IL
D
IN
G
R
A
N
G
E
F
IR
IN
G
H
P
U
C
I
D
U
P
C
L
O
P
I
U
P
I
A
S
A
D
M
I
N
B
P
O
B
U
I
L
D
I
N
G
C
O
V
E
R
E
D
B
A
S
K
E
T
B
A
L
L
C
O
U
R
T
P
N
C
O
F
U
T
U
R
E
F
U
T
U
R
E
O
N
-
B
A
S
E
H
O
U
S
I
N
G
F
U
T
U
R
E
O
N
-B
A
S
E
H
O
U
S
IN
G
E
X
P
A
N
S
I
O
N
F
U
T
U
R
E
C
O
N
C
E
S
S
I
O
N
A
I
R
E
&
O
T
H
E
R
F
A
C
I
L
I
T
I
E
S
H
O
U
S
E
N
S
EW
G
A
T
E
2
O
U
T
P
O
S
T
S
E
C
U
R
IT
Y
P
A
R
K
I
N
G
A
R
E
A
P
A
R
K
I
N
G
A
R
E
A
P
A
R
K
I
N
G
A
R
E
A
P
A
R
K
I
N
G
A
R
E
A
P
A
R
K
I
N
G
P
A
R
K
I
N
G
B
A
R
R
A
C
K
S
W
A
T
E
R
R
E
S
E
R
V
O
I
R
CAMP DEVELOPMENT PLANSCALE 1:1000M
SIDE DEVLOPMENT PLANSCALE 1:50M
E
X
I
S
T
I
N
G
R
O
A
D
THIS SITE
PERSPECTIVE VIEWSCALE NTS
E
N
T
R
A
N
C
E
G
A
T
E
M
O
T
O
R
P
O
O
L
P
C
L
O
P
I
A
S
P
H
S
G
P
A
R
K
I
N
G
A
R
E
A
E
X
I
S
T
I
N
G
R
O
A
D
GROUND FLOOR PLAN
WORK AREA
QUARTERS
STORAGE
SUPPLY ROOM
D4
D1
D2
B
A
1 2 3
C
B
A
W1
W2W3W3
W1
RO
OF
LIN
E
ROOF LINE
ROOF LINE
RO
OF
LIN
E
FF2
UP
UP
FRONT ELEVATIONSCALE 1:100M
REAR VIEW ELEVATIONSCALE 1:100M
RIGHT SIDE ELEVATIONSCALE 1:100M
LEFT SIDE ELEVATIONSCALE 1:100M
SECTION "A"SCALE 1:100MTS
1 2 3
12
3
C B A
SEE DETAILED SECTION
CBA
1 2 3
CBA
D1
W3 W3
W2W4
D1a
W1
W1
W1
D1a D3
WF2
WF1
RF2
RF1
WF1
CHIEF
W5
TOP OF ROOF BEAM
TOP OF ROOF STEEL ROOF GIRT
F.F.L.
N.G.L.
F.F.L.
TOP OF ROOF BEAM
TOP OF ROOF STEEL ROOF GIRT
APEX OF CANOPY TRUSS
N.G.L.
F.F.L.
TOP OF ROOF BEAM
N.G.L.
N.G.L.
F.F.L.
TOP OF ROOF BEAM
TOP OF ROOF STEEL ROOF GIRT
TOP OF ROOF BEAM
TOP OF ROOF STEEL ROOF GIRT
F.F.L.
N.G.L.
SECTION "B"SCALE 1:100MTS
WORK AREAQUARTERS
W1
WORK AREA CHIEF
W1
APEX OF CANOPY TRUSS
N.G.L.
F.F.L.
TOP OF ROOF BEAM
TOP OF ROOF STEEL ROOF GIRT
SEE DETAILED SECTION
STEEL CASEMENT WINDOW
W TRANSOM
PROVIDE 3 SETS
STEEL CASEMENT WINDOW
W TRANSOM
PROVIDE 1 SET
STEEL CASEMENT WINDOW
W TRANSOM
PROVIDE 3 SETS
STEEL AWNING WINDOW
PROVIDE 1 SET
ALUMINUM FRAMED GLASS
SWING DOOR WITH TRANSOM
PROVIDE 1 SET
ALUMINUM FRAMED GLASS
SWING DOOR
PROVIDE 1 SET
PVC DOOR
SWING DOOR
PROVIDE 2 SETS
SCHEDULE OF DOORSSCALE 1:50M
SCHEDULE OF WINDOWSSCALE 1:50M
PANEL DOOR
PROVIDE 2 SETS
D3
D3
D1 D2 D3 D4
W4
STEEL AWNING WINDOW
PROVIDE 1 SET
W1 W2 W3 W4 W5
W1
W5
A-2
SHEET NO.SUBMITTED BY:
APPROVED BY:
RECOMMEND APPROVAL:
CHECKED BY:PREPARED BY:PROJECT TITLE:
LOCATION: LOCATION:
Republic of the Philippines
NATIONAL POLICE COMMISSION
PHILIPPINE NATIONAL POLICE
Camp Quintin M Merecido, Davao City
Kidalapong, Malita, Davao Occidental
ENGINEERING SERVICE
REGIONAL PROJECT MANAGEMENT UNIT 11
Director, ES
Police Chief Superintendent
PHILIP LAWRENCE S ABAPO, III
POLICE SENIOR INSPECTOR
ANTONIO A TAYLAN, JR
Asst. Chief, RPMU
MARIA DEOVINA G SEVILLANO
Police Chief Inspector
Acting Chief, RPMU
ABELARDO C MATILLANO
Police Senior Superintendent
Chief of Staff, ES
MANUEL G FABROS
Police Senior Superintendent
Deputy Director, ES
DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE
Acting Chief, ID, ES
HONORIO R AGNILA
Police Superintendent
PROPOSED PROVINCIAL HEADQUARTERS SUPPORT GROUP
GENERAL NOTES:
ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL BUILDING CODE,
PROVISIONS OF THE LATEST APPROVED PHILIPPINE ELECTRICAL CODE, THE LAWS AND ORDINANCES OF
THE LOCAL CODE ENFORCING AUTHORITIES AND REQUIREMENTS OF THE LOCAL ELECTRIC, TELEPHONE
COMPANY AND BUILDING ADMINISTRATION REQUIREMENTS.
ALL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF LICENSE DULY REGISTERED
ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN.
1. CONTRACTOR SHALL SECURE ALL WIRING PERMIT AND ALL FEES REQUIRED FOR THE WORKS AND
FURNISH THE OWNER THE CERTIFICATE OF FINAL ELECTRICAL INSPECTION,
2. CONTRACTOR SHALL CONDUCT EARTH GROUND TEST, WIRE INSULATION AND LOAD TEST UPON
COMPLETION OF WORKS,
3. INCASE OF DISCREPANCY BETWEEN PLANS AND SITE CONDITION, SPECIFICATIONS & REVISIONS
CHANGES, THE CONTRACTOR SHOULD IMMEDIATELY VERIFY & CONSULT TOWITH THE
OFFICER-IN-CHARGE OF THE CONSTRUCTION (OICC) OF THE PNP ENGINEERING SERVICE (PNPES),
4. ALL LOCATION & MOUNTING HEIGHT ARE SUBJECT TO APPROVAL OF THE OICC OF PNPES,
5. CONTRACTOR SHALL BE RESPONSIBLE IN THE PREPARATION OF AS-BUILT PLANS DULY SIGNED
AND SEALED BY PROFESSIONAL ELECTRICAL ENGINEER, AND ELECTRONIC AUTOCAD FILES,
6. FINAL LIGHTING FIXTURES AND WIRING DEVICES SHALL BE APPROVED BY PNPES,
OICCREPRESENTATIVEENGINEER,
7. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF SHOP OR CONSTRUCTION DRAWING
REQUIRED BY OICCOWNERARCHITECHENGINEER, THIS INCLUDES DEVICES AND FIXTURES
ELEVATION,
8. CONTRACTOR SHALL VISIT SITE CONDITION AND INCLUDE ALL COST NECESSARY TO COMPLETE
THE SYSTEM AT NO COST TO OWNER, INCLUDING COST OF CORING SERVICE AND EXPENSES FOR
THE RESTORATION OF ANY DAMAGE AFFECTED CIVIL STRUCTUTAL ARCHITECTURAL FINISHES OR
RELOCATION OF EXISTING FACILITIES ON BUILDING,
9. CONTRACTOR SHALL LOCATE ALL SPLICING BOXES TO ACCESSIBLE PLACE OR WITH ACCESS
PANELS,
10. NOMINATED CONTRACTOR TO VERIFY ALL EQUIPMENTS TO BE INSTALLED OR PLACE WITHIN THE
BUILDING SITE, AND MAKE AN ADJUSTMENT WITH THE PNPES OICCENGINEER ARCHITECT
CONSENT,
11. THIS DRAWINGS ARE DIAGRAMATIC LAYOUT ONLY, ANY MATERIALS AND FITTINGS NOT SHOWN ON
THIS PLANS BUT NEEDED TO COMPLETE THE SYSTEM AND OPERATION SHALL BE INCLUDED WITH
THE CONTRACTOR'S SCOPE OF WORKS.
12. ADDITIONAL NOTES:
· USE OF MICA SHALL BE LIMITED TO 150mm MAXIMUM
· USE OF FLEXIBLE METALLIC & NON METALLIC CONDUTIT SHALL BE LIMITED TO 1m MAXIMUM
· PROVIDE PROPER CONDUIT SUPPORT, G.I. WIRES AS SUPPORT SHALL NOT BE ALLOWED
· PROVIDE DOUBLE COAT OF RUST PROTECTIVE PAINT (RED OXIDE PRIMER) ON HANGERS AND
SUPPORTS.
SPECIFICATIONS:
1. POWER SUPPLY TO THE BUILDING SHALL BE 230V, SINGLE PHASE,
2-WIRES, 60HZ.
2. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR
PURPOSE & LOCATION.
3. NORMAL AND EMERGENCY CIRCUIT SHALL NOT BE COMBINED IN ONE
RACEWAY OR CONDUIT.
4. RECEPTACLES FOR GENERAL USE SHALL BE DUPLEX 16A, 250VAC,
GROUND TYPE.
5. ALL WIRES SHOULD HAVE A MAXIMUM LOAD OF 80 OF WIRE AMPACITY.
6. LIGHT SWITCHES MINIMUM RATING SHALL BE 16A 230VAC.
7. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND SHALL HAVE THE
"P.S." MARKS.
8. MOUNTING HEIGHTS SHALL BE AS FOLLOWS:
A. LIGHT SWITCHES - 1.37m above Floor finish
B. CONVENIENCE OUTLET - 0.3m above Floor finish
C. TELEPHONE OUTLET - 0.3m above Floor finish
D. PANEL BOARD - 1.8m ABOVE FLOOR FINISH
9. CONDUIT EMBEDED WITHIN CONCRETE WALL SHALL HAVE A MINIMUM
CEMENT PLASTERED OF 20mm THICK.
10. ALL CONDUIT PIPE ABOVE CEILING SHOULD HAVE INDEPENDENT
HANGER SUPPORTS.
11. ALL LIGHTING FIXTURES SHOULD HAVE INDEPENDENT HANGER
SUPPORTS.
12. ALL BOXES SHALL BE OCCUPIED ONLY OF 50 OF WIRE VOLUME.
13. VOLTAGE DROP SHALL BE LIMITED TO 2.5 FROM SOURCE TO PANEL
BOARD AS P.E.C. REQUIREMENT OR ACCEPTABLE TO THE LABORATORY
EQUIPMENT.
14. CIRCUIT BREAKERS SERVING MOTORS AND LIGHTING SHALL BE
INDUSTRIAL AND COMMERCIAL BOLT-ON TYPE RESPECTIVELY WITH
MINIMUM OF 6kAIC.
15. ALL WIRES AND CABLES SHALL BE BRAND NEW AND APPROVED TYPE.
16. USE SOLDERLESS CONNECTOR, MECHANICAL 1 PRESSURE TYPE COPPER
LUGS FOR CONNECTION OF WIRES LARGER THAN 8mm².
17. USE FILLER COMPOUND, "SCOTCH FILL" OR APPROVED EQUAL AT SHARP
EDGES TO PROVIDE SMOOTH SURFACE BEFORE TAPING WITH
ELECTRICAL TAPE.
LED EMERGENCY LIGHT
9W LED DOWNLIGHT
1-GANG OF 3-SINGLE POLE SWITCHESSabc
DP1 DP1-DISTRIBUTION PANEL 1
LEGEND & SYMBOLS
GFCI
DUPLEX CONVENIENCE OUTLET WITH GROUND
DUPLEX CONVENIENCE OUTLET WITH GROUND, GFCI
CIRCUIT HOMERUN, A-ACU CIRCUIT HOMERUN,L-LIGHTING CIRCUIT HOMERUN, C-CONVENIENCEOUTLET CIRCUIT HOMERUN
1 x 18 LED TUBE, BOX TYPE
1-GANG OF 2-SINGLE POLE SWITCHESSab
2-WIRE SERVICE ENTRANCE
SWITCH CONDUIT RUN
LIGHTING CIRCUIT CONDUIT RUN
RECEPTACLE OUTLET CIRCUIT CONDUIT RUN
225 AT3PCIRCUIT BREAKER
1
PROFESSIONAL ELECTRICAL ENGINEER
REG NO: PTR NO: TIN:
ISS. AT: ISS. ON: TEL:
NOTE: Sign and Seal of Electrical plans is the sole authority of a PROFESSIONAL ELECTRICALENGINEERR.A. 7920 Section 31, 32 & 34. Field of Practice and Prohibition in the Practice of Electrical Engineeringand preparation of plans, supervision of installation, application of the Philippine Electrical Code.
It shall be unlawful for any person not authorized under this Act to prepare plans, electricalvaluations or specifications for any electrical wiring, equipment or system; and no installation thereofshall be undertaken unless the plans, designs, valuations and specifications have been prepared by orunder the responsible charge of, and signed and sealed by a professional electrical engineer; and theconstruction permit for the execution thereof is first secured; and unless the work is done in accordancewith the Philippine Electrical Code and is executed under the responsible charge or supervision of aPROFESSIONAL ELECTRICAL ENGINEER or REGISTERED ELECTRICAL ENGINEER or Registered MasterElectrician, as the case may be, and the routinary fiscal and ministerial requirements of the governmentagency, if any, exercising jurisdiction over the particular installation have been complied with.
TABLE OF CONTENTSSHEET
NO
SHEET CONTENTS
DRAWING
NO
E1 GENERAL NOTES & SPECIFICATIONS 1
LEGEND & SYMBOLS 2
LOCATION & SITE DEVELOPMENT PLAN 3
C
H
A
P
E
L
E
N
T
R
A
N
C
E
G
A
T
E
O
U
T
P
O
S
T
M
O
T
O
R
P
O
O
L
S
E
C
U
R
IT
Y
P
A
R
A
D
E
G
R
O
U
N
D
G
R
A
N
D
S
T
A
N
D
H
P
U
C
I
D
U
P
C
L
O
P
I
U
I
A
S
B
P
O
F
U
T
U
R
E
C
O
N
C
E
S
S
I
O
N
A
I
R
E
&
O
T
H
E
R
F
A
C
I
L
I
T
I
E
S
T-150kVAL3, P3
P1
T-250kVAL1, P4
P5
P6
P2
LOCATION AND SITE DEVELOPMENT PLAN
N
A
T
I
O
N
A
L
R
O
A
D
I
A
S
B
P
O
P1
P2
2 - 14mm² THHN/THWN Cu WireIN 25 mm dia PVC
SERVICE ENTRANCE POLE4650mm High
N
S
EW
SHEET NO.SUBMITTED BY:
APPROVED BY:
RECOMMEND APPROVAL:
CHECKED BY:PREPARED BY:PROJECT TITLE:
LOCATION: LOCATION:
Republic of the Philippines
NATIONAL POLICE COMMISSION
PHILIPPINE NATIONAL POLICE
Camp Quintin M Merecido, Davao City
Kidalapong, Malita, Davao Occidental
PROPOSED PROVINCIAL HEADQUARTERS GROUP
ENGINEERING SERVICE
REGIONAL PROJECT MANAGEMENT UNIT 11
Director, ES
Police Chief Superintendent
PHILIP LAWRENCE S ABAPO, III
POLICE SENIOR INSPECTOR
ANTONIO A TAYLAN, JR
Asst. Chief, RPMU
MARIA DEOVINA G SEVILLANO
Police Chief Inspector
Acting Chief, RPMU
ABELARDO C MATILLANO
Police Senior Superintendent
Chief of Staff, ES
MANUEL G FABROS
Police Senior Superintendent
Deputy Director, ES
DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE
Acting Chief, ID, ES
HONORIO R AGNILA
Police Superintendent
E-1
GROUND FLOOR PLANSCALE 1:100M
WORK AREA
QTRS
STORAGE
SUPPLY ROOM
1 2 3
C
A
W1
RO
OF
LIN
E
ROOF LINE
ROOF LINE
RO
OF
LIN
E
8.00
UP
UP
CHIEF
4.00 4.00
7.00
3.50
3.50
2.20
4.00 4.00
0.60
1.70
1.20
CKT
NO.
Panel Board: SCHEDULE OF LOADSOCPD
No. & Size of Wire
and Conduit
DESCRIPTION LO COSPOGFCI
Total Volts kVA Amps AT, AF, POLE,kAIC
WIRE mm²/ PVC mmØ
1 Lighting Outlet 13 13 230 1.30 5.65 15, 50, 2, 6 2-3.5 THHN 20
2 Lighting Outlet 10 10 230 1.00 4.35 15, 50, 2, 6 2-3.5 THHN 20
3 Convenience Outlet 5 1 6 230 1.08 4.70 20, 50, 2, 6 2-3.5 THHN 20
4 Convenience Outlet 4 0 4 230 0.72 3.13 20, 50, 2, 6 2-3.5 THHN 20
5 1.5HP WT ACU 1 1 230 2.30 10.00 20, 50, 2, 6 2-5.5 THHN 20
6 1HP WT ACU 1 1 230 1.84 8.00 20, 50, 2, 6 2-5.5 THHN 20
7 SPARE 0 0 230 1.84 8.00 20, 50, 2, 6 20
Sub-total 23 9 3 35 10.08 43.83
COMPUTATIONS OF LOADS: PANEL BOARD
Iw (Ampacity of Wire)= (Total current, It x Demand factor,df) + 25 of Largest motor
Iw (Wire ampacity) = 43.83 + 2.50 = 46.33 USE: 2 - 14 mm² THHN/THWN in 25 mm Ø RSC PIPE
Icb (Main Over Current Protection Device)= Iw + Largest motor
Icb (Main OCPD) = 46.33 + 10.00 = 56.33 8 Branches Panel Board, 100AF with 60 AT Main CB, Bolt-on, Center Main, 2 Pole, 240V, 60Hz withGrounding Lugs
SERVICE ENTRANCE2-WIRE, SINGLE PHASE
kWhr METERCLASS 1002-14mm² THW Cu Wire
in 25mm Ø PVC Pipe
20 A, 2P 20 A, 2P
1
3
5
2
4
6
LIGHTING OUTLET
RECEPTACLE OUTLET
1.5HP WT ACU
LIGHTING OUTLET
RECEPTACLE OUTLET
PANELBOARD
1HP WT ACU
SINGLE LINE DIAGRAM
M
15 A, 2P
20 A, 2P
15 A, 2P
20 A, 2P
2-14mm² THW Cu Wirein 25mm Ø RSC Pipe
PROFESSIONAL ELECTRICAL ENGINEER
REG NO: PTR NO: TIN:
ISS. AT: ISS. ON: TEL:
NOTE: Sign and Seal of Electrical plans is the sole authority of a PROFESSIONAL ELECTRICAL ENGINEERR.A. 7920 Section 31, 32 & 34. Field of Practice and Prohibition in the Practice of Electrical Engineering andpreparation of plans, supervision of installation, application of the Philippine Electrical Code.
It shall be unlawful for any person not authorized under this Act to prepare plans, electrical valuations orspecifications for any electrical wiring, equipment or system; and no installation thereof shall be undertakenunless the plans, designs, valuations and specifications have been prepared by or under the responsible chargeof, and signed and sealed by a professional electrical engineer; and the construction permit for the executionthereof is first secured; and unless the work is done in accordance with the Philippine Electrical Code and isexecuted under the responsible charge or supervision of a PROFESSIONAL ELECTRICAL ENGINEER orREGISTERED ELECTRICAL ENGINEER or Registered Master Electrician, as the case may be, and the routinaryfiscal and ministerial requirements of the government agency, if any, exercising jurisdiction over the particularinstallation have been complied with.
TABLE OF CONTENTSSHEET
NO
SHEET CONTENTS
DRAWING
NO
E2 LIGHTING & POWER LAYOUT 1
SCHEDULE OF LOADS & COMPUTATIONS 2
SINGLE LINE DIAGRAM 3
SERVICE ENTRANCE DETAIL 4
SERVICE ENTRANCE POLE4650mm High
SERVICE ENTRANCESINGLE PHASE, 240VAC, 60Hz2 - 14 mm² THHN/THWN Cu Wirewith Messenger
DRIP LOOPat least 1500
58" Ø EYEBOLT
GALVANIZED with SPOOL INSULATOR
KWHR METER
USE SOLDERLESSCONNECTORS
DP60 AT
25 mm Ø RSC with clamps2-14mm² THHN Cu Wire
DETAIL OF SERVICE ENTRANCE
N. G. L.
SERVICE POLE DETAILNOT TO SCALE
TOP
STEEL BARSSTIRRUPS
4 STEEL BARSBOTHWAYS
1.00M
0.30M
1.00
M
1.50
M
0.30
M
0.35
M
1.00M
0.20M
NOTE: COORDINATE TO THESTRUCTURAL ENGINEER FORTHE SIZE OF STEEL BARS
NGL
2 - 14mm² THHN/THWN Cu Wirewith Messenger SERVICE DROP LINE
2 - 14mm² THHN/THWN Cu WireIN 25 mm dia PVC
Sd
a
a
b
a
Sa
Sbc Sa
Sabc
cc
cc
a a b b
Sab
a
a
d d
d
d
Sa
Sb
b
2
1
3
5
6
4
GFCI
LIGHTING & POWER LAYOUT
2 - 14mm² THHN/THWN Cu WireIN 25 mm dia PVC
SERVICE ENTRANCE POLE4650mm High
b c
c
B
GROUND FLOOR PLANSCALE 1:100M
WORK AREA
QTRS
STORAGE
SUPPLY ROOM
1 2 3
C
A
W1
RO
OF
LIN
E
ROOF LINE
ROOF LINE
RO
OF
LIN
E
8.00
UP
UP
CHIEF
4.00 4.00
7.00
3.50
3.50
2.20
4.00 4.00
0.60
1.70
1.20
B
60 AT3P
3.5250
4.0000 7 8SPARE SPARE20 A, 2P
MAIN SERVICE EQUIPMENT60AT in NEMA 3R Enclosures
(DOUBLE THROW SWITCHBREAKER TYPE
for provision of GENSET)
MAIN SERVICE EQUIPMENT60AT in NEMA 3R Enclosures
(DOUBLE THROW SWITCHBREAKER TYPE
for provision of GENSET)
E-2
SHEET NO.SUBMITTED BY:
APPROVED BY:
RECOMMEND APPROVAL:
CHECKED BY:PREPARED BY:PROJECT TITLE:
LOCATION: LOCATION:
Republic of the Philippines
NATIONAL POLICE COMMISSION
PHILIPPINE NATIONAL POLICE
Camp Quintin M Merecido, Davao City
Kidalapong, Malita, Davao Occidental
ENGINEERING SERVICE
REGIONAL PROJECT MANAGEMENT UNIT 11
Director, ES
Police Chief Superintendent
PHILIP LAWRENCE S ABAPO, III
POLICE SENIOR INSPECTOR
ANTONIO A TAYLAN, JR
Asst. Chief, RPMU
MARIA DEOVINA G SEVILLANO
Police Chief Inspector
Acting Chief, RPMU
ABELARDO C MATILLANO
Police Senior Superintendent
Chief of Staff, ES
MANUEL G FABROS
Police Senior Superintendent
Deputy Director, ES
Acting Chief, ID, ES
HONORIO R AGNILA
Police Superintendent
PROPOSED PROVINCIAL HEADQUARTERS GROUPDAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE
ALL PLUMBING WORKS SHALL BE DONE IN ACCORDANCE W THE LATEST PROVISIONS
ALL VERT SOIL & WASTE STACK PIPE SHALL BE EXTEND FULL SIZE ABOVE ROOF LINE
PROVIDE 50MM Ø P-TRAP FOR EVERY 100M M Ø X 100MM Ø FLR DRAIN
PROVIDE CLEANOUT FOR EVERY FIFTEEN METERS ( 15.00 M ) DISTANCE
ALL CHANGES IN PIPE SIZES ON SOIL WASTE LINE SHALL BE MADE W THE REDUCING
OF THE NATIONAL PLUMBING CODE
AS VENTS EXCEPT OTHERWISE SPECIFICALLY INDICATED
FITTINGS OR RECESS REDUCERS
HORIZONTAL LINE
PROVIDE STOP-COCK FOR EVERY FIXTURES
120m
m
LIFTING COVER
R.C. COVER W STL
STORM DRAINAGE
PIPE LINE
4-12Ø MM
10 MM O BARS
CHB WALL W
BARS BOTHWAYS
10 MM THK
DRAIN LINE
PLASTERED FIN.
LIFTING COVER
R.C. COVER W STL
SECTION
CO CLEAN-OUT
FD FLOOR DRAIN
SHO SHOWER
CV CHECK VALVE
GV GATE VALVE
VSTR VENT STACK THRU ROOF
M WATER METERLAV LAVATORY
WC WATER CLOSET
SV SEPTIC VAULT
URI URINAL
DS DOWNSPOUT
PVC POLYVINYL CHLORIDE
DRAINAGE PIPE LINE
LAV LAVATORY
WC WATER CLOSET
UR URINAL
COLD WATER LINE
P L A N
NOTE:
VERIFY SIZE OF SEPTIC TANK TO LOCATION
.40 X .40
6" CHB
MANHOLE
4" CHB
6" CHB
12MM∅ BARS
SPACED @ .20M
O.C BW
S E C T I O N
AIR SPACE
WATER LEVEL
CHAMBER
DIGESTIVE
.40M
WF1
∅12 LIFT BAR
AIR SPACE
WATER LEVEL
CHAMBER
LEACHING
CHAMBER
LEACHING
21
12MM∅ BARS
SPACED @ .20M
O.C BW
4" CHB
6" CHB
TO
M
AIN
SE
WE
R L
IN
E
OU
TL
ET
P
IP
E
TO
S
EP
TIC
V
AU
LT
IN
LE
T P
IP
E
TO MAIN
SEWER LINE
OUTLET PIPE
TO
SEPTIC VAULT
INLET PIPE
FAU FAUCET
PLAN
WATER LEVEL
AIR SPACE
SOIL PIPE LINE
CB CATCH BASIN
VENT PIPE LINE
PPR POLYPROPYLENE RANDOM
NOT TO SCALE
1
P1 NOT TO SCALE
1
P2
P-1
SHEET NO.SUBMITTED BY:
APPROVED BY:
RECOMMEND APPROVAL:
CHECKED BY:PREPARED BY:PROJECT TITLE:
LOCATION: LOCATION:
Republic of the Philippines
NATIONAL POLICE COMMISSION
PHILIPPINE NATIONAL POLICE
Camp Quintin M Merecido, Davao City
Kidalapong, Malita, Davao Occidental
ENGINEERING SERVICE
REGIONAL PROJECT MANAGEMENT UNIT 11
Director, ES
Police Chief Superintendent
PHILIP LAWRENCE S ABAPO, III
POLICE SENIOR INSPECTOR
ANTONIO A TAYLAN, JR
Asst. Chief, RPMU
MARIA DEOVINA G SEVILLANO
Police Chief Inspector
Acting Chief, RPMU
ABELARDO C MATILLANO
Police Senior Superintendent
Chief of Staff, ES
MANUEL G FABROS
Police Senior Superintendent
Deputy Director, ES
DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE
Acting Chief, ID, ES
HONORIO R AGNILA
Police Superintendent
PROPOSED PROVINCIAL HEADQUARTERS SUPPORT GROUP
2
SCALE 1:100MTS
SANITARY LINES LAYOUT
UP
WM
CV
GV
WATER LINES LAYOUTSCALE 1:100M
SCALE 1:100MTS
CB
CBCB
CB
DSDS
DS
CB
DS
STORM DRAINAGE LAYOUT
1 2 3
C
B
A
1 2 3
C
B
A
1 2 3
C
B
A
P-2
SHEET NO.SUBMITTED BY:
APPROVED BY:
RECOMMEND APPROVAL:
CHECKED BY:PREPARED BY:PROJECT TITLE:
LOCATION: LOCATION:
Republic of the Philippines
NATIONAL POLICE COMMISSION
PHILIPPINE NATIONAL POLICE
Camp Quintin M Merecido, Davao City
Kidalapong, Malita, Davao Occidental
ENGINEERING SERVICE
REGIONAL PROJECT MANAGEMENT UNIT 11
Director, ES
Police Chief Superintendent
PHILIP LAWRENCE S ABAPO, III
POLICE SENIOR INSPECTOR
ANTONIO A TAYLAN, JR
Asst. Chief, RPMU
MARIA DEOVINA G SEVILLANO
Police Chief Inspector
Acting Chief, RPMU
ABELARDO C MATILLANO
Police Senior Superintendent
Chief of Staff, ES
MANUEL G FABROS
Police Senior Superintendent
Deputy Director, ES
DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE
Acting Chief, ID, ES
HONORIO R AGNILA
Police Superintendent
PROPOSED PROVINCIAL HEADQUARTERS SUPPORT GROUP
100MM THK. SLAB ON FILL WITH
10MM Ø BEDBARS SPACED @
0.40M O.C. B.W.
1 2 3
C
B
A
F-2C-1
F-1C-1
F-1
C-1
F-2
C-1
F-1C-1
F-2
C-1
F-1
C-1
F-2C-1
WF-1 WF-1
WF-1 WF-1
WF
-1
WF
-1
WF
-1
WF
-1
WF-2
WF-2
WF-2
WF
-2
ROOF FRAMING PLANSCALE 1:100MTS
1 2 3
C
B
A
DETAIL OF ROOF GIRT
ROOF BEAM
ROOF GIRT
ROOF BEAM
ROOF BEAM ROOF BEAM
RO
OF
B
EA
MR
OO
F B
EA
M
RO
OF
B
EA
MR
OO
F B
EA
M
RA
FT
ER
- 1
RA
FT
ER
- 1
RA
FT
ER
- 1
RA
FT
ER
- 1
RA
FT
ER
- 1
RA
FT
ER
- 1
CA
NO
PY
T
RU
SS
- 1
CA
NO
PY
T
RU
SS
- 1
CA
NO
PY
T
RU
SS
- 1
A
1 2
3
DETAILED SECTIONSCALE 1:25MTS
SCALE 1:50MTS
WF - 2
TOP OF ROOF BEAM
APEX OF STEEL ROOF GIRT
2
-2
"X
6
" C
- C
H
A
N
N
E
L
S
A
S
R
A
F
T
E
R
2-2"X
6" C
- C
H
AN
N
ELS
AS
R
AF
TE
R
2" Ø SCHED 40 G.I. PIPE TOP AND BOTTOM CHORDS
B C
R O O F B E A M R O O F B E A M
2"X4" C - PURLINS WITH 2" X 2" ANGLE BAR CLEATS
0.4MM THK RIB TYPE ROOFING
10MM Ø SOG ROD
DETAIL OF ROOF BEAMSCALE 1:25MTS
WF - 1
F - 1
F - 2
C - 2
SECTION
S-1
SHEET NO.SUBMITTED BY:
APPROVED BY:
RECOMMEND APPROVAL:
CHECKED BY:PREPARED BY:PROJECT TITLE:
LOCATION: LOCATION:
Republic of the Philippines
NATIONAL POLICE COMMISSION
PHILIPPINE NATIONAL POLICE
Camp Quintin M Merecido, Davao City
Kidalapong, Malita, Davao Occidental
ENGINEERING SERVICE
REGIONAL PROJECT MANAGEMENT UNIT 11
Director, ES
Police Chief Superintendent
PHILIP LAWRENCE S ABAPO, III
POLICE SENIOR INSPECTOR
ANTONIO A TAYLAN, JR
Asst. Chief, RPMU
MARIA DEOVINA G SEVILLANO
Police Chief Inspector
Acting Chief, RPMU
ABELARDO C MATILLANO
Police Senior Superintendent
Chief of Staff, ES
MANUEL G FABROS
Police Senior Superintendent
Deputy Director, ES
DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE
Acting Chief, ID, ES
HONORIO R AGNILA
Police Superintendent
PROPOSED PROVINCIAL HEADQUARTERS SUPPORT GROUP