ENCE 3610Soil Mechanics
Lecture 7Empirical and Field Tests for Hydraulic
ConductivityDewatering
![Page 3: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/3.jpg)
Typical Permeability Values
![Page 4: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/4.jpg)
Empirical Correlations and Typical ValuesGranular Soils
Based on tests bolstered by a varying amount of theoryHazen’s Correlation
k in cm/sec0.8 < C < 1.2 (typically C = 1)Limited to soils with 0.1 mm < D10 < 3 mm and Cu < 5
Typical valuesAssume laminar flow in soil
k=CD102
![Page 5: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/5.jpg)
Example of Conductivity Estimate
Given: Soil as Shown Below
D10 = 0.15D5 = 0.08Uniformity Coefficient Cu = 8Void Ratio e = 0.6
FindHydraulic Conductivity, using a variety of methods
Methods to be used if applicable)
Hazen’s CorrelationLaboratory Tests Chart
SolutionHazen’s Correlation
0.1 < D10 < 5 is true, but cannot use since Cu = 8 > 5
Lab TestsCan use since 2 < Cu = 12 and D10/D5 = 1.88 > 1.4For D10 = 0.1 and e = 0.6, k = 0.015 cm/sec = 0.05 fpm (see chart on previous slide)
![Page 6: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/6.jpg)
Field Permeability Tests and Dewatering Wells
Field permeability tests measure the coefficient of permeability (hydraulic conductivity) of in-place materials.The area and length factors are often combined in a "shape factor" or "conductivity coefficient."Measurement of permeability is highly sensitive to both natural and test conditions.Field permeability tests are also the “inverse” of the pumping problem for dewatering.
Test types parallel lab testsConstant Head TestVariable Head Tests
Rising Head TestFalling Head TestInfiltration Test
Pumping TestGravity and Pressure
Tests
![Page 7: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/7.jpg)
Confined and Unconfined Aquifers
![Page 8: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/8.jpg)
Confined Aquifer: Determination of Height• Governing Equation:
– h=height from bottom of well to water level at well
– h0=water table height from bottom of well to water table
– Q0=flow from well– k=coefficient of permeability– H=thickness of permeable layer– r=radius of well or wherever h
is measured– R=outer boundary of influence
of well, or wherever h0 is measured
⎟⎠⎞
⎜⎝⎛+=
Rr
kHQhh ln
20
0 π
( )00
ln
2 hh
Rr
kHQ −⎟⎠⎞
⎜⎝⎛
=π
( )0
0
2
ln
hhHRrQ
k−
⎟⎠⎞
⎜⎝⎛
=π
![Page 9: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/9.jpg)
Unconfined Aquifer
• Only difference is that upper layer is the same (pervious) as lower layer
• Equations have same variables, but expression is different:
( )
( )20
2
0
20
20
020
2
ln
ln
ln
hhRrQ
k
hh
RrkQ
Rr
kQhh
−
⎟⎠⎞
⎜⎝⎛
=
−⎟⎠⎞
⎜⎝⎛
=
⎟⎠⎞
⎜⎝⎛+=
π
ππ
![Page 10: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/10.jpg)
Dewatering
![Page 11: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/11.jpg)
Measuring Permeability in Cohesive Soils (Rising Head Test)
![Page 12: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/12.jpg)
Layered Soils
“Resistor Model” except that we’re dealing in conductivities, not resistancesFor horizontal layers:
Vertical flow is a single flow through several hydraulic resistances in series
Horizontal flow is several flows through several hydraulic resistance in parallel
k H (eq)=1H∑1
n
k HnHn
kV (eq )=H
∑1
n Hn
kV n
![Page 13: This document downloaded from … · z Measurement of permeability is highly sensitive to both natural and test conditions. z Field permeability tests are also the “inverse” of](https://reader033.vdocuments.mx/reader033/viewer/2022041818/5e5c8debeb5b466643163d08/html5/thumbnails/13.jpg)
Anisotropy in Permeability
Can be significant, esp. with some types of clays, esp. varved clays
Varved clay: “alternating seams or layers of sand, silt and clay” (SFH Table 4.7)Result of sediment deposits with vary in nature due to seasonal fluctuations, etc.
k H≠ k V (Anisotropic Soil)k H>kV ( in general )