thermo plan manual zeigle blocks
TRANSCRIPT
![Page 1: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/1.jpg)
“The Science of Nature - The Future of Construction”“The Science of Nature - The Future of Construction”
Blocks
Product Guide
NBT ThermoPlan® Ziegel Blocks
Thin Bed InsulatingSolid Wall System
![Page 2: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/2.jpg)
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Excellent Thermal Performance
Cost Efficient
No Cavity
Simple Detailing
Rapid , Easy Construction
Very Breathable
Complete System
Environmentally Sound
Build from Cellar to Eaves
Full Range of Internal Blocks
Compatible Mortars, Renders
and Plasters all included
Full Design and Application
Support from NBT
“Modern Method of Construction”
(MMC) approved by The Housing
Association.
Zurich Insurance Approved
NBT Ziegel System
Real Thin Bed Construction
Complete Building System
ThermoPlan®
Build high performance solid fired clay block
walls quickly and cost effectively
1mm bed joints with dry interlocking vertical
joints for high laying rates with no limit on
height per day and no drying-out shrinkage
Fully compatible range of ‘special’ shapes,
internal blocks, lintols, light-
weight mortars, plasters and renders.
fixings and tools,
Thermally Superior
All-round Performance
Highly vapour open external walls easily meet
Part L requirements without condensation risk
to create a comfortable, healthy internal
environment
Internal blocks can be used for Part E
approved separating wall types and all
blocks are non-combustible providing 30 to
120 minutes fire resistance
Load - bearing
Block crushing strength of 6 N/mm for
external insulating blocks and up to 12
N/mm for internal acoustic wall blocks is
more than adequate for most domestic and
low-rise construction
²
²
Thin Bed Insulating Block Solid Wall System
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Additional Benefits
�
�
�
�
�
�
�
�
�
�
Finished construction is airtight
No cavity or vertical dpc
No risks from interstitial condensation
No drying shrinkage
Low wastage
No toxins or irritants in use
Environmentally clean manufacture
Very Low CO Burden
Stable Construction -
Good thermal mass
No risks from weather penetration
Suitable for cellar walls
�
�
2
Build up to 25 linear
metres without the need for expansion joints.
NBT
-Pro
duc
tD
esc
rip
tio
nTh
erm
op
lan
®Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
![Page 3: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/3.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT Ziegel SystemThermoPlan®
The blocks are extruded with vertical perforations.
Sawdust and polystyrene particles are mixed in
with the clay matrix which, during firing, burn
away to give a micro-porous structure. The
combination of voids and pores gives the blocks
their unique thermal properties.
After firing the blocks are planed top and bottom
to within 0.5mm tolerance.
Blocks are available in a full range of sizes,
shapes, widths and densities and are suitable for
almost all masonry applications in low-rise
residential and commercial construction.
Design with
The most cost efficient and robust form of
construction is a rendered solid 'breathing'
external wall that exceeds building regulation
requirements without cavities, membranes or
additional insulation.
Insulating blocks can carry loads from concrete
floors and can also be used as infill panels in
framed buildings. It is also possible to use them
below dpc level with tanking to build cellars
internal walls are denser
so they have better load-bearing, acoustic and
thermal storage properties but lower thermal
insulation. Internal blocks can be used to meet
the requirements for separating walls and have
excellent fire resistance.
external walls are
weather and air tight, very vapour permeable,
excellent for thermal insulation and also for
protection against summer over-heating, fire
resistant and with good acoustic properties.
NBT Ziegel Blocks
NBT Ziegel
NBT Ziegel
ThermoPlan
ThermoPlan
ThermoPlan
®
®
®
Tolerances
The blocks are very accurate ONLY in the height
dimension. The width and length dimensions are
within normal manufacturing limits for building
materials.
The accuracy of the top and bottom faces allows
the use of very thin bed joints and fast laying
rates. We do however recommend allowing a
10mm bed of normal mortar every storey to
avoid cumulative errors.
Solid -Ziegel walls are not designed to be
built fair-faced. Normal variations in block width
are hidden by the lightweight render and plaster
layers, which are also important for thermal and
acoustic insulation and air-tightness.
Plan
NBT has full design, training and application support to ensure successful
construction with the ThermoPlan - system.NBT Ziegel®
NBT
-Pro
duc
tD
esc
rip
tio
nTh
erm
op
lan
®Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
The better way to build
![Page 4: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/4.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Building with
Accurate thin bed joints, dry interlocking vertical
joints, easy handling and cutting, and a full range
of lintols and accessory blocks mean fast
construction times, assured performance, good
cost benefits and lower skill requirements.
Time spent setting out the level of the 1 course
accurately together with good site planning gives
real benefits in site productivity.
The thin joint mortar is easy to apply either from a
special roller or by dipping each block in a
shallow tub of mortar. Blocks are then simply
stacked on the mortar bed, with perp joints
interlocked and mortar free.
Maintaining bond is easy using half blocks or by
cutting the blocks with purpose made saws, and
filling the gaps with insulating mortar.
The mortar gains strength and stiffness quickly so
a storey height can be built in 1 day ready for the
floor or roof the next day.
The build process is virtually dry so the wall is
immediately ready for finishing without the risk of
long-term drying out shrinkage.
There is very little wastage of material because of
the large range of special blocks and the ease of
accurate cutting.
st
NBT ZiegelThermoPlan®
NBT BaumitBayosan Renders & Plaster Finishes
For the most cost effective construction use
render and plaster wall finishes to provide air and
weather tightness and additional thermal
insulation.
NBT supply a full range of lightweight, hydraulic
lime based materials that are specially designed
and approved for
blocks and are readily available for machine or
hand application in a range of attractive colours
and textures.
A variety of cladding systems can also be used
including timber, tile hanging and brick and stone
facings.
NBT ZiegelThermoPlan®
NBT
-Pro
duc
tD
esc
rip
tio
nTh
erm
op
lan
®Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
The better way to build
NBT has full design, training and application support to ensure successful
construction with the ThermoPlan - system.NBT Ziegel®
![Page 5: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/5.jpg)
NBT
The
rmo
pla
n®
Zie
ge
l-
Syste
mO
ptio
ns
NBT Thermoplan® System
Rendered Solid Wall
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
15mm Mineral Render
System & Mineral Paint
300mm T11 Ziegel Block
(thin bed mortar system)
12mm Mineral Plaster
NBT Breathable Trade
Emulsion
15mm BaumitBayosan Render
System and Decor Finish
NBT Breathable Trade Emulsion
NBT BlockThermoplan®
12mm Mineral Plaster
NBTZiegel Block
Thermoplan® K-Value(W/mK)
U-Value(W/m K)²
300mm Wide 0.10 0.31
0.10 0.26
0.10 0.24
365mm Wide
400mm Wide
425mm Wide 0.10 0.22
ZT1
0
ZV10
0.11 0.33
0.11 0.28
300mm Wide
365mm WideZT1
1
ZV11
0.12 0.36
0.12 0.30
0.12 0.28
0.12 0.26
0.12 0.23
ZT1
2
ZV12
300mm Wide
365mm Wide
400mm Wide
425mm Wide
490mm Wide
Thin bed insulating breathing solid
wall system.
Single skin construction - No Cavity.
Quick and easy to construct and
finish.
Simplest NBT Thermoplan System to
build.
Breathing Construction.
![Page 6: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/6.jpg)
NBT Thermoplan® Plus System
Rendered Insulated Solid Wall
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
15mm Mineral Render
System & Mineral Paint
300mm T11 Ziegel Block
(thin bed mortar system)
12mm Mineral Plaster
NBT Breathable Trade
Emulsion
8mm BaumitBayosan
Render System Finish on
NBT Pavatex Diffutherm
Woodfibre Insulation
NBT Breathable Trade
Emulsion
NBT
Block
Thermoplan®
12mm Mineral Plaster
NBTZiegel Block
Thermoplan® + 60mmDiffutherm
+ 80mmDiffutherm
+ 100mmDiffutherm
300mm Wide 0.22 0.20 0.18
0.19 0.17 0.16
0.18 0.17 0.16
365mm Wide
400mm Wide
425mm Wide 0.17 0.16 0.15
ZT1
0
ZV10
Thin bed insulating solid wall system
over clad with NBT Rendered
Diffutherm Woodfibre EWI.
Excellent Acoustic Performance.
Very breathable system with
excellent ecological profile.
Very low U-Values achievable -
Ideal for low-energy structures.
U-Values
(W/m K)² U-Values shown rounded up/down
NBT
The
rmo
pla
n®
Zie
ge
l-
Syste
mO
ptio
ns
Other denser block ranges are available for higher admittance (thermal mass) and for
greater load-bearing capacity. Please contact NBT for details.
0.24 0.22 0.20
0.22 0.20 0.18
0.20 0.19 0.17
0.20 0.18 0.17
0.18 0.16 0.15
ZT1
2
ZV12
300mm Wide
365mm Wide
400mm Wide
425mm Wide
490mm Wide
0.23
0.27
0.21
0.24
0.19
0.22
0.20 0.19 0.17
300mm Wide
240mm Wide
365mm Wide
ZT1
1
ZV11
![Page 7: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/7.jpg)
NBT Thermoplan® CladPlus System
Clad Insulated Solid Wall
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
15mm Mineral Render
System & Mineral Paint
300mm T11 Ziegel Block
(thin bed mortar system)
12mm Mineral Plaster
NBT Breathable Trade
Emulsion
Cladding facade over
NBT Pavtherm Plus
Woodfibre Insulation
NBT Breathable Trade
Emulsion
NBT
Block
Thermoplan®
12mm Mineral Plaster
Thin bed insulating solid wall system
over clad with NBT Pavatherm Plus
Waterproofing EWI board.
Very low U-Values achievable -
Ideal for low-energy structures.
Excellent Acoustic Performance.
Very breathable system with
excellent ecological profile.
NBTZiegel Block
Thermoplan® + 60mmPavaTherm +
+ 80mmPavaTherm +
+ 100mmPavaTherm +
300mm Wide 0.22 0.20 0.18
0.19 0.18 0.16
0.18 0.17 0.16
365mm Wide
400mm Wide
425mm Wide 0.17 0.16 0.15
ZT1
0
ZV10
U-Values
(W/m K)*²
NBT
The
rmo
pla
n®
Zie
ge
l-
Syste
mO
ptio
ns
0.24 0.22 0.20
0.22 0.20 0.18
0.20 0.19 0.17
0.20 0.18 0.17
0.18 0.16 0.15
ZT1
2
ZV12
300mm Wide
365mm Wide
400mm Wide
425mm Wide
490mm Wide
0.23
0.27
0.21
0.24
0.19
0.22
0.20 0.19 0.17
300mm Wide
240mm Wide
365mm Wide
ZT1
1
ZV11
* U-Values shown rounded up/downand exclude cladding system
Other denser block ranges are available for higher admittance (thermal mass) and for
greater load-bearing capacity. Please contact NBT for details.
![Page 8: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/8.jpg)
NBT Thermoplan® Clad System
Clad Insulated Solid Wall
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
Thin bed insulating solid wall system
compatible with most types of
cladding systems
Cladding non structural
Suitable for Brick / Stone outer skin
Cladding / facing can be built as a
secondary stage allowing main
structure to built and made
watertight - fast tracks build time
15mm Mineral Render
System & Mineral Paint
300mm T11 Ziegel Block
(thin bed mortar system)
12mm Mineral Plaster
NBT Breathable Trade
Emulsion
Cladding facade over
BaumitBayosan Render
NBT Breathable Trade
Emulsion
NBT
Block
Thermoplan®
12mm PlasterMineral
15mm Mineral Render
System & Mineral Paint
300mm T11 Ziegel Block
(thin bed mortar system)
12mm Mineral Plaster
NBT Breathable Trade
Emulsion
BaumitBayosan
Render
NBT Breathable
Trade Emulsion
NBT Thermoplan®
12mm Mineral
Plaster
15mm Mineral Render
System & Mineral Paint
300mm T11 Ziegel Block
(thin bed mortar system)
12mm Mineral Plaster
NBT Breathable Trade
EmulsionNBT Breathable
Trade Emulsion
NBT Thermoplan®
12mm PlasterMineral
15mm Mineral Render
System & Mineral Paint
300mm T11 Ziegel Block
(thin bed mortar system)
12mm Mineral Plaster
NBT Breathable Trade
Emulsion
BaumitBayosan
Render
NBT Breathable
Trade Emulsion
NBT Thermoplan®
12mm PlasterMineral
NBTZiegel Block
Thermoplan®
300mm Wide 0.31
0.26
0.24
365mm Wide
400mm Wide
425mm Wide 0.22
ZT1
0
ZV10
0.33
0.28
300mm Wide
365mm WideZT1
1
ZV11
0.36
0.30
0.28
0.26
0.23
ZT1
2
ZV12
300mm Wide
365mm Wide
400mm Wide
425mm Wide
490mm Wide
U-Values
(W/m K) *²
Typical Cladding Types
Rain Screen
on Rail System
Timber
Cladding
on battens
Brick / Stone
Cladding
BaumitBayosan
Render
BaumitBayosan
Render
* U-Values Shown exclude cladding system
NBT
The
rmo
pla
n®
Zie
ge
l-
Syste
mO
ptio
ns
![Page 9: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/9.jpg)
NBT Thermoplan® Internal Systems
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
Thin bed insulating solid internal wall
system.
Excellent Acoustic Performance.
Reduces plaster cracking at
junctions to Thermoplan external
walls due to no thermal expansion
differentials.
Available in varying densities to suit
application and loading
requirements.
NBTZiegel Block
Thermoplan®
NBTZiegel Block
Thermoplan®
ZA08Range
ZA08Range
ZA12Range
ZA12Range
ZA14Range
ZA14Range
115mm Wide
2 x 115mm Wide
38
58
41
62
45
63
42
64
45
66
47
68
45
66
49
70
50
71
175mm Wide
2 x 175mm Wide
240mm Wide
2 x 240mm Wide
AcousticPerformance
NBT
The
rmo
pla
n®
Zie
ge
l-
Syste
mO
ptio
ns
48 51 53 55 58ZF08 Range
Width (mm) 145 175 200 240 300
Ratings shown as per DIN4109 R’w R, (dB)
(Finished wall platered both sides)Single Skin Partition Walls
Double Skin Party Wall (Insulation Filled 30mm Cavity)
NBT Render System
Thin Bed Wall Tie
NBT Thermoplan Full Ziegel
Concrete In-Fill
Internal Plaster
Internal Plaster
30mm Insulation
Filled Cavity
Movement Bead
67 70 tba tba tba2 x ZF08 Range
Width (mm) 145 175 200 240 300
![Page 10: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/10.jpg)
NBT
-Pro
duc
tRa
ng
eThe
rmo
pla
n®
Zie
ge
l
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT RangeThermoPlan®
External Thermal Block
ZT1
1ZT1
2
ZT11365F
300 247 249 54
ZT12300F
ZT12365F
ZT12400F
ZT12425F
ZT12490F
300
365
400
425
490
247
247
247
247
247
249
249
249
249
249
54
40
40
36
30
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M²
Stk Per
M³
M
Pallet
² Per KG per
Block
3.37 16 54 12.7
3.37 16 54 12.0
2.50 16 44 14.6
2.50 16 40 16.0
2.25 16 38 17.0
1.87 16 33 19.6
External Thermal - Full Blocks
ZV1
1ZV1
2
ZV11300F
ZV11365F
300
365
247
247
249
249
45
40
ZV12300F
ZV12365F
ZV12400F
ZV12425F
ZV12490F
300
365
400
425
490
247
247
247
247
247
249
249
249
249
249
45
40
40
36
30
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M²
Stk Per
M³
2.81 16 54 12.0
M
Pallet
² Per KG per
Block
2.50 16 44 14.6
2.81 16 54 12.0
2.50 16 44 14.6
2.50 16 40 16.0
2.25 16 38 17.0
1.87 16 33 19.6
External Thermal - Full Blocks - Meshed Reinforced Bed
EN
DC
ORN
ER
ZT00300C
ZT00365C
ZT00400C
ZT00425C
300
365
400
425
490
175
247
280
300
For corners use 1x 365 Full Block & 1 x 365 Corner Block
249
249
249
249
54
40
32
24
Article No:
Article No:
Thickness
mm
Thickness
mm
Length
mm
Length
mm
Height
mm
Height
mm
Stk Per
Pallet
Stk Per
Pallet
Stk Per
M²
Stk Per
M²
Stk Per
M³
Stk Per
M³
ZT00300E
ZT00365E
300
365
123
123
249
249
90 na na na 5.8
na na na 7.080
M
Pallet
² Per
M
Pallet
² Per
KG per
Block
KG per
Block
na na na 8.2
na na na 13.5
na na na 19.5
na na na 22.5
External Thermal - End Blocks (T&G on one side only)
External Thermal - Corner Blocks (T&G on one side only)
ZT1
0ZT10300F
ZT10365F
ZT10400F
300
365
400
247
247
247
249
249
249
54 3.37 16 54 12.0
2.50 16 44 14.6
2.50 16 40 16.0
40
40
ZT10425F 425 247 249 2.25 16 38 17.036
Zv1
0
ZV10300F
ZV10365F
ZV10400F
300
365
400
247
247
247
249
249
249
54 3.37 16 54 12.0
2.50 16 44 14.6
2.50 16 40 16.0
40
40
ZV10425F 425 247 249 2.25 16 38 17.036
ZT11300F
365 247 249 40 2.50 16 44 15.5
Zt00425 E 425 123 249 42 na na na 8.4
![Page 11: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/11.jpg)
ZT00365HR 365 123 249 32 2.50 na na 7.3
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
MA
KE
UP
REVEA
L
ZT00300R
ZT00365R
300
365
247
247
249
249
30
30
ZT00300HR 300 123 249 36
ZT00300M
ZT00365M
300
365
247
247
113
113
70 na 32 na 5.3
na 32 na 6.4
na na na 12.2
64
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M²
Stk Per
M³
M
Pallet
² Per KG per
Block
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M²
Stk Per
M³
M
Pallet
² Per KG per
Block
na na na 14.6
na na na 6.1
External Thermal - Make Up Bricks (half Height)
External Thermal - Reveal Blocks (Full and Half Length)
AN
GLE
ZT00300A
ZT00365A
300
365
na
na
249
249
27
24
na na na 17.0
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M²
Stk Per
M³
M
Pallet
² Per KG per
Block
na na na 26.0
External Thermal - Angle Blocks (For 45° / 135° Corners)
UW
U
ZT00300U
ZT00365U
300
365
240
240
240
240
45
40
ZT00300WU 300 240 240 60
11.25 4 na 8.7
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M
Stk Per
M³
M Per
Pallet
KG per
Block
10 4 na 10.0
15 4 na 12.0
ZT00365WU 365 240 240 40 10 4 na 11.8
External Thermal - Special Sections (For Creating Lintols, Ringbeams, Reinforced Columns, Service Voids Etc.)
WL
ZT00365WL 365 240 240 60 15 4 na 12.0
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M
Stk Per
M³
M Per
Pallet
KG per
Block
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M
Stk Per
M³
M Per
Pallet
KG per
Block
LIN
TOL
ZT00300R*
ZT00365R*
* Available in following lengths: 1 - 1.25 - 1.5 - 1.75 - 2 - 2.25 - 2.5 & 2.75M(Please specify as follows: ZT00300R150 = 1.50 metre 300mm wide x 113 high)
300
365
See
Below
113
113
na
na
na na na 46.0
Article No: Thickness
mm
Length
mm
Height
mm
Stk Per
Pallet
Stk Per
M²
Stk Per
M³
M
Pallet
² Per KG per
M
na na na 56.0
External Thermal - Precast Lintol Sections (Lengths as below)
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT RangeThermoPlan®
External Thermal Block
NBT
-Pro
duc
tRa
ng
eThe
rmo
pla
n®
Zie
ge
l
ZT00400U
ZT00425U
400
425
240
240
240
240
?
?
? 4 na ?
? 4 na ?
ZT00490U 490 240 240 ? ? 4 na ?
![Page 12: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/12.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Article No:
Article No:
Article No:
BYAM51
BYYWER131
BYVLTM81
Description
Description
Description
Ext / Int Bead Setting Mortar
1m x 50m Wide Reinforcing Mesh for Openings
Insulating Mortar / Filling Compound
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT
-Pro
duc
tRa
ng
eThe
rmo
pla
n®
Zie
ge
l
NBT RangeThermoPlan®
System Components
ZXM617
ZXM617 ZXM618
ZT Mortar (un-meshed) 42
42
40
3 1.5 na 25
25
25
BYMP69KG3 External Lightweight Base coat 35301.7 sqm @ 15mm
BYY1151
BYY3727
FXTAPE15
NBT offer a full range of external mineral render finishes in a pallette of
over 250 colours in grain sizes from 0 - 5mm. Please contact NBT for
further details.
Ext Galvanized Corner Mesh Bead
APU Sealing Bead 13mm for Window / Door Frames
VSA Compriband Sealing Strip 12.5mm Wide 3-15 Thick
2.95
2.6
6.0
BYLL66
BBYY1152
External / Internal Lime Base coat *
Ext Stainless Steel Corner Mesh Bead
36
2.95
351.9 sqm @ 15mm
BYRK38A Internal Lime Base coat 36351.9 sqm @ 15mm
BYYWE17SS Int / Ext Stainless Steel Corner Mesh Bead (Visible Nosing) 3.0
BYRK30A
BYY1225
Internal Lime Skim coat
Ext Galvanized Bellcast Stop Bead
42
3.0
2510 sqm @ 3mm
BYIS20 Internal Lime / Gypsum Skim coat 422510 sqm @ 3mm
BYLS62 External Plinth Render 35351.9 sqm @ 15mm
BYY2229
BYY1223
BYY7503
Ext Stainless Steel Stop Bead
Ext Galvanized Steel Stop Bead with PVC Nosing
Ext Galvanized Steel Movement Joint Profile (6mm joint)
3.0
3.0
3.0
30 Linear M
40 Ltr Volume
ZXM618 ZV Mortar (Meshed) 42na na 1.5 25
Article No: Description
Rollfix
Dipping
ZT
System
ZV
System
System Variables
Stk Per
Pallet
Stk Per
Pallet
Length
(M)
Length
(M)
Pallet
per bag
Pallet
per bag
Pallet
per bag
KG per
Bag
KG per
Bag
Coverage
per Bag
ZXM891 300mm Wide Mesh for ZV 100m Roll
100m RollZXM892 365mm Wide Mesh for ZV
Article No: Description
NBT Thermoplan Thin Bed Mortar (Supplied with blocks when ordered)
Bed Reinforcement Mesh for ZV System (Supplied with blocks when ordered)
Render and Plaster Products
* (not suitable for ZT10 / ZV10 Range)
Re
nd
ers
&
Pla
ste
rsBe
ad
sSe
alin
gM
isc
![Page 13: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/13.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Plan-Ziegel BlocksPlan-Ziegel Blocks
Laying NBT ZiegelThermoPlan®
Lay the damp-proof course on a thin
mortar bed on the slab or sub-
structure. Group 3 mortar should be
used (for this course only).
Cover The DPC with a further amount
of mortar and accurately level the
bed joint using the levelling rails or
setting blocks (See “Setting Out Methods”)
Position the first block and ensure that
it is accurate in plumb and
alignment.
Thin Bed Mortar should be mixed with
9 -11 Ltrs. of clean, cold water per
bag - max 2 bags at a time. Mix
thoroughly with a power stirrer and
allow to stand for 10 minutes
Place a second block at the next
corner / opening - string a line
between - then lay the first course
directly onto the mortar bed. Do not
twist blocks to “settle” - use a rubber
mallet to gently tap them down.
Pour thin bed mortar into roller
applicator. Roller should be
thoroughly cleaned after use and
lightly oiled to prevent corrosion.
Using the roller applies the correct
amount of mortar to the surface of
the blocks.
Position the next course of blocks with
the interlocking profile fully engaged.
Only use mortar on non-interlocking
joints - cut joint, corner, abutments etc.
Tap into place with a rubber mallet.
Plan site layout to avoid unnecessary
man handling - easy handling saves
the builder time and effort.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Preparation and Laying
of First Course
![Page 14: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/14.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Roller Applicators for thin bed mortar.
Maintenance and Use.
The Standard Mortar Applicator is the
most basic of the three models
available.
ZXT895 240mm Wide
For applying mortar to the ZT external
blocks and the ZA internal range the
425mm Wide
ZT-Sytem applicator should be used -
available in three sizes to suit the
range -
ZXT877 175 & 240mm Wide
300 & 365mm WideZXT879
ZXT880
Should the meshed system of the ZV
external blocks range be being used
or if adding mesh to internal sections
the ZV
again
ZXT886
425mm Wide
applicator should be used -
in three sizes to suit the range -
ZXT885 175 & 240mm Wide
300 & 365mm Wide
ZXT887
In warm weather stand roller unit in
cold water during work breaks.
Only use the thin bed mortar as
supplied by NBT with the roller
applicators.
Pull roller in on direction only - avoid
going back and forward over blocks.
Mesh, if used, can be cut with a utility
knife (stored on unit).
Unsure that a good even coverage
has been achieved.
Thoroughly wash unit after use - oil
with a light oil to prevent corrosion.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Mortar Laying Tools
![Page 15: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/15.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Setting out and using Levelling Rails
Setting out and laying of the first
course of Plan-Ziegel is critical if the
speed advantage of the system is to
be maximised - Using NBT’s levelling
rail set makes this a simple process.
Set the first frame at the highest point
of the slab / footing.
Adjust the level the rail frame in both
directions - setting as low as possible.
Attach the laser target staff and target
if used, to the frame and set laser
height so as laser beam in line with a
datum mark.
Each frame has an adjustable rod
that can be used to set width of bed
to be laid. Set these to suit width of
block being used, 300, 365, 425 etc.
Set down second frame and adjust
level and height in relation to first
frame. Attach laser target staff to
check height.
Spread a thin layer of Group 3 mortar
onto the slab / sub-structure between
the two frames. Roll out DPC then
cover with a further amount of Mortar.
Rule off the mortar bed using a
suitable straight edge / level. Using a
trowel remove excess mortar to leave
a neat, straight edge to the bed.
Trim off excess mortar to leave a neat
bed. Leaving the second frame in
position move the first frame along the
slab, level off and check height as
before. Continue around site till
returning to initial start / datum point.
Dependant of the size of the site you
can either a) Start laying the first course
directly onto the mortar bed if still “soft”
or b) Allow bed to dry and lay blocks
following day onto a thin bed of Ziegel
mortar spread by Roller Applicator.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
ZXT863 Leveling Rails
![Page 16: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/16.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Corners and Wall Terminations
Reveal Blocks
Angle Blocks
Corner and End Blocks are available
for corners and wall terminations.
These blocks have the interlocking
profile on one face only and the
ribbing of the blocks is also heavier.
Coursing of corner blocks should be
as shown (See Construction details
section for more detailed
information.)
The non-interlocking joint should be
filled with Baumit-Bayosan LTM81
insulating mortar to prevent cold
bridging through the joint.
For improved weather protection at
window and door frames the reveal
and half reveal blocks should be
used.
Frames should be installed with a
Compriband strip and an APU sealing
rail prior to rendering.
Coursing of reveal blocks should be
as shown (See Construction details
section for more detailed
information.)
For direction changes of 45 NBT
supply a pre-formed angle block that
maintains the interlocking profile.
° Other angles require the block to be
cut and the joint filled with LTM81
insulating mortar.
Coursing of angle blocks should be as
shown (See Construction details
section for more detailed
information.)
Reveal Blocks
Angle Blocks
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Special Blocks
![Page 17: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/17.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Wall Junctions
Stainless Steel thin bed wall tie plates
should be used in each course at wall
Junctions
Using a coarse file/rasp cut a groove
in the top surface on the block.
Cutting the groove eliminates rocking
of the block.
Bend the wall ties to form a 90 angle.
(To prevent injury from ties protruding
until abutting wall section built.) Bed
tie in thin bed mortar.
°
Ties should be installed in alternate
courses as a minimum 1 tie for
115mm and wide and 2 ties for all
other widths and for the PFZ blocks.
The abutting wall should be built with
a 10-15mm mortar joint to the main
wall section.
Just prior to building the abutting wall
bend the tie straight.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Building Techniques
Building Curved Wall Sections
Building curved wall sections with
Ziegel is simple especially when
compared to curved twin element
cavity construction.
For a radius less than 3.5m
Cut the blocks to form a taper. LTM81
should still be used in the joint due to
the lack of interlocking profile.
For a radius greater than 3.5m
Open up the joint by a maximum of
20mm. The open joint should then be
filled with LTM81 insulating mortar.
![Page 18: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/18.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Lintols, Ringbeams and Padstones.
Pre-cast lintol sections are available
in lengths from 1m - 2.75m in
increments of .25m. in a range of
widths to suit most applications. (see
data sheet)
The lintol section should be laid on a
10mm bed of group 3 mortar with
one to two courses of make up
blocks over.
A minimum support length of 125mm
should be allowed at the bearing
points. The lintol should be propped
at centres no greater than 1M during
installation and curing.
For higher loads/wide spans the
Thermoplan range of U or WU blocks
should be used.
At wall terminations the end block
should be turned through 90 to cap
the end of the run.
°
Blocks should be laid over a suitable
support / former during construction.
Bed the blocks on a 10mm bed of
group 3 mortar.
Instal reinforcement bars / cage and
fill with grade of concrete to
engineers specification. The U and WU
blocks may be used to create lintols,
ringbeams ....
padstones and service voids. The WL block can be used for creating
an insulated bearer for floor slabs.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Building Techniques
U Block
WL Block
WU Block
![Page 19: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/19.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Using Thermoplan Full Ziegel
As for all Thermoplan blocks the first
course should be laid on a 10-15mm
bed of group 3 mortar
Subsequent courses should be laid
using the Thermoplan Thin Bed Mortar
as supplied with the blocks
The blocks can be dipped into a bath
of mortar or the mortar can be
applied by a Thermoplan roller.
The wall section should be built with
interlocking joints mortar free. Build the
complete wall section ready for
backfilling with concrete.
Once filled the wall section will
achieve high load capacity with
excellent heat storage and acoustic
qualities.
The system blocks should be built as
half-bond to allow the void to be fully
filled with concrete to engineers
specification.
The abutment connection should be
made using a 10-15mm mortared
joint to the main wall element.
Thin bed wall ties should be installed
at every course and positioned to
project into the filling void as shown.
DO NOT fit or omit ties from the
junction.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Building Techniques
![Page 20: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/20.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Floors, In-fill Panels and Basements
Thermoplan blocks can be used with
most conventional flooring
techniques...
With precast slab, block and beam or cast in-situ.
Thermoplan Ziegel blocks are the
ideal solution to in-fill panels within a
steel or concrete frame construction.
The ZT range can be laid to lengths of
up to 25 linear metres and the ZV,
reinforced bed range up to 40
without expansion or movement
joints.
The ability to build longer lengths of
wall sections without the need for
expansion joints is a major plus when
building large scale units such as
commercial or multi-storey blocks.
Thermoplan Ziegel blocks can be
used for basement wall construction
to provide an insulated structure.
Once built the external face should
be primed before applying a
waterproofing membrane such as
Bituthene or similar.
The membrane should be further
protected using a drainage protection
board. The drainage protection board
protects the membrane from being
punctured whilst also reducing hyro-
static pressure.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Building Techniques
![Page 21: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/21.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Cutting, Chasing and Drilling
The preferred methods of cutting
Thermoplan blocks are by a alligator
type saw such as the Dewalt DW390
(L) saw available from most tool
merchants.
NBT supply a longer 475mm blade
bar and the blades to suit that can
be easily fitted to the DeWalt Alligator
saw to enable the blocks to be cut in
one pass.
Alternatively a large capacity
diamond block saw should be used
such as the G lz BS650 or BS900.ö
Cutting of channels for electrical
services etc. should be created by
first cutting the side slots with a twin
wheel diamond wall chaser...
Do not use a “hammer and bolster”
or powered impact hammer
technique as this will crack the inner
core of the blocks.
once cut use a wide faced bolster to
“break” the core of the channel by
levering sideways.
Conventional TCT or Diamond tipped
drilling tools and core bits should be
used to drill the blocks.
DO NOT USE HAMMER / PERCUSSION
ACTION - doing so will crack the inner
core of the blocks and lead to
oversized hole creation.
Suitable safety protection should be
worn during all cutting, drilling and
chasing operations. Were possible use
dust extraction to lower the dust levels.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Building Techniques
![Page 22: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/22.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Thermoplan Finishes
NBT Supply a full range of approved
external renders and internal plaster
finishes from the Baumit-Bayosan
range of mineral products....
together with a full range of render
and plaster accessories.
Render and plaster beads, services
conduit etc. should be bed in Baumit-
Bayosan AM51 quick set mortar.
Diagonal strips 250mm wide of
Wemico R131 reinforcing mesh
should be applied over the corners of
openings to eliminate stress cracks
appearing in the render coat.
NBT supply an extensive range of
decor finishes in grain sizes from 0mm
to 5mm in a pallet of over 250
colours. Please contact NBT for further
details.
A base coat of Baumit-Bayosan MP69
base render should applied to a
thickness of 12 - 15mm
The internal face of Thermoplan are
best “hard plastered” with the Baumit-
Bayosan range of Lime or
Lime/Gypsum base mineral plasters
although other methods of finishing
can be used. Please contact NBT for
advice.
The final external finish of Thermoplan
does not have to be a render....
Cladding materials such as timber,
rain screen systems can also be
utilized. .
Stone or brick Skins may also be used -
the type of material will determine if a
drainage cavity will be required or not.
Please contact NBT for details.
NBT
-C
onstruc
tio
nM
eth
od
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Building Techniques
LL66
One-Coat
Lime
RK38
Lime
Base
RK30
Lime
Skim
IS20
Lime-Gypsum
Skim
![Page 23: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/23.jpg)
Course Details - 490 Wall Thickness
490F Full Block (Length = 247mm)
365F Full Block (Length = 247mm)
365C Corner Block (Length = 247mm)
490E End Block (Length = 247mm)
1st, 3rd Course etc. 2nd, 4th Course etc.
500 Wide Column
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Course Details - 300 Wall Thickness
300F Full Block (Length = 247mm)
300C Corner Block (Length = 175mm)
300E End Block (Length = 123mm)
1st, 3rd Course etc. 2nd, 4th Course etc.
500 Wide Column
Course Notes:
Blocks should be laid in a staggered bond with a minimum overlap of 95mm
The first Course should be laid using Group 3 Mortar with a horizontal DPC running through.
All subsequent bed joints to be made using thin bed mortar as supplied with the blocks.
All non interlocking joints and abutments should be filled with Baumit-Bayosan LTM81 light weight insulating mortar.
Course Details - 365 Wall Thickness365F Full Block (Length = 247mm)
365C Corner Block (Length = 247mm)
365E End Block (Length = 123mm)
1st, 3rd Course etc. 2nd, 4th Course etc.
500 Wide Column
Course Details - 400 / 425 Wall Thickness400F / 425F Full Block (Length = 247mm)
400C / 425C Corner Block (L = 400C 280mm / 425C 300mm)
400C / 425C Corner Block (Cut to ½ Length i.e. 140 / 150mm*)
1st, 3rd Course etc. 2nd, 4th Course etc.
500 Wide Column
400C / 425C Corner Block (Cut to 2/3 Length i.e. 186 / 200mm*)
400C / 425C Corner Block (Cut to 1/3 Length i.e. 93 / 100mm*)
NBT
-C
onstruc
tio
nD
eta
ilsThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Construction Details
![Page 24: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/24.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Course Details - 300 Wall Thickness
300A Angle Block
300F Full Block (Length = 247mm)
300C Corner Block (Length = 247mm)
1st, 3rd Course etc.
2nd, 4th Course etc.
300E End Block (Length = 123mm)
Course Details - 300 Wall Thickness
300F Full Block (Length = 247mm)
300R Reveal Block (Length = See Below:)
300HR Half Reveal Block (Length = See Below:)
1st, 3rd
Course etc.
Course Details - 365 Wall Thickness
365A Angle Block
365F Full Block (Length = 247mm)
365C Corner Block (Length = 247mm)
1st, 3rd Course etc.
2nd, 4th Course etc.
365E End Block (Length = 123mm)
Course Details - 365 Wall Thickness
365F Full Block (Length = 247mm)
365R Reveal Block (Length = See Below:)
365HR Half Reveal Block (Length = See Below:)
1st, 3rd
Course etc.
2nd, 4th
Course etc.
Compriband Seal
APU Seal
2nd, 4th
Course etc.
NBT
-C
onstruc
tio
nD
eta
ilsThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Construction Details
![Page 25: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/25.jpg)
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
Plan-Ziegel BlocksPlan-Ziegel Blocks
Fixings For External Block Range Fixings For Internal Block Range
NBT CompatibleThermoplan® Ziegel
Fixings Selector and application guide.
Loading Data
Axial / Edge Spacings
NBT supply a range of fixings for various applications from the Fischer Fixings System range of mechanical
anchors. These fixings have been selected and tested for use in Plan-Ziegel range of internal and external
blocks. A selection of sizes are shown below: Please contact NBT or Fischer Fixings UK for further details .
UX- R Universal Plug Range:
For light duty fixings - electrical fittings, bathroom accessories, small cupboards, skirting
boards etc
FUR - T Frame Anchors Range:
For standard door sets, timber rails and battens, light duty shelving etc.
FIS - V Injection Mortar System:
For heavy or dynamic loads - large door frames, kitchen wall cupboards, toilets, sinks
UX 6 x 50R UNIVERSAL PLUG
FACE FIXING
0.11kN 0.06kN*
END FIXING
UX 6 x 50R UNIVERSAL PLUG
FACE FIXING
0.14kN 0.13kN
END FIXING
FUR 8 x 80T FRAME ANCHOR
FACE FIXING
0.16kN 0.14kN
END FIXING
FUR 8 x 80T FRAME ANCHOR
FACE FIXING
0.25kN 0.21kN
END FIXING
FIS - V INJECTION MORTAR**
FACE FIXING
0.30kN 0.30kN
END FIXING
FIS - V INJECTION MORTAR**
FACE FIXING
0.30kN 0.30kN
END FIXING
** Load value using FIS H N anchor sleeve with FIS E K screw with 5mm wood screw
*Not Recommended
UX 6
FUR 8 T
FIS V with FIS H N Sleeve 200mm
150mm
100mm Any reduction in these spacings will lead to a
reduction in the recommended load.
In order to achieve the maximum performance from
any anchor when installed in masonry it is necessary
to install the anchor as close to the centre of the block
/ brick as possible. In addition, if multiple anchors are
to be installed into a brick / block they should be
installed with the largest axial spacing possible.
NBT
-Fix
ing
sThe
rmo
pla
n®
Zie
ge
l
NBT ThermoPlan® Ziegel BlocksNBT ThermoPlan® Ziegel Blocks
NBT ZiegelThermoPlan®
Fixings Range
![Page 26: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/26.jpg)
ZT10300F ZT10365F ZT10400F ZT10425F
mm 300 365 400 425Dimension Length mm 247 247 247 247
Dimension Width mm 300 365 400 425
Dimension Height mm 249 249 249 249
6 6 6 6
kg/m³ 650 650 650 650
N/mm² 7,5 7,5 7,5 7,5
W/mK 0,10 0,10 0,10 0,10W/m²K 0,31 0,26 0,24 0,22
kJ/m²K 195 237 260 276
kN/m³ 8 8 7,5 8
N/mm² 0.6 0.6 0.6 0.61 1 1 1
[mm/m] 0 0 0 010-6K 6 6 6 6
dB ** ** ** **
F 90 A F 90 A F 90 A F 90 A
µ 5 - 10 5 - 10 5 - 10 5 - 10
No./ m³ 54 44 40 38
No./ m² 16 16 16 16L/m³ 11 11 11 11
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stressFinal creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Ziegel blocksThin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 650 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZT10
● Thin Bed Insulating Solid Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-857
![Page 27: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/27.jpg)
ZT11300F ZT11365F
mm 300 365Dimension Length mm 247 247
Dimension Width mm 300 365
Dimension Height mm 249 249
6 6
kg/m³ 700 700
N/mm² 7,5 7,5
W/mK 0.11 0.11W/m²K 0.33 0.28
kJ/m²K 210 255
kN/m³ 8 8
N/mm² 0.8 0.81 1
[mm/m] 0 010-6K 6 6
dB ** **
F 90 A F 90 A
µ 5 - 10 5 - 10
No./ m³ 54 44
No./ m² 16 16
L/m³ 6.5 6.5
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stressFinal creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Ziegel blocks
Thin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 700 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Natura l Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: info@natura l-building.co.uk web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZT11
● Thin Bed Insulating Solid Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-869
![Page 28: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/28.jpg)
ZT12300F ZT12365F ZT12400F ZT12425F ZT12490F
mm 300 365 400 425 490Dimension Length mm 247 247 247 247 247
Dimension Width mm 300 365 400 425 490
Dimension Height mm 249 249 249 249 249
6 6 6 6 6
kg/m³ 650 650 650 650 650
N/mm² 7.5 7.5 7.5 7.5 7.5
W/mK 0.12 0.12 0.12 0.12 0.12W/m²K 0.36 0.3 0.28 0.26 0.23
kJ/m²K 180 219 240 255 297
kN/m³ 7.5 7.5 7.5 7.5 7.5
N/mm² 0.8 0.8 0.8 0.8 0.80.75 0.75 0.75 0.75 0.75
[mm/m] 0 0 0 0 010-6K 6 6 6 6 6
dB ** ** ** ** **
F 30 A F 30 A F 30 A F 30 A F 30 A
µ 5 - 10 5 - 10 5 - 10 5 - 10 5 - 10
No./ m³ 54 44 41 38 33
No./ m² 16 16 16 16 16
L/m³ 6.5 6.5 6.5 6.5 6.5
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stressFinal creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Ziegel blocks
Thin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 650 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZT12
● Thin Bed Insulating Solid Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-698
![Page 29: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/29.jpg)
ZV10300F ZV10365F ZV10400F ZV10425F
mm 300 365 400 425Dimension Length mm 247 247 247 247
Dimension Width mm 300 365 400 425
Dimension Height mm 249 249 249 249
6 6 6 6
kg/m³ 650 650 650 650
N/mm² 7,5 7,5 7,5 7,5
W/mK 0,10 0,10 0,10 0,10W/m²K 0,31 0,26 0,24 0,22
kJ/m²K 195 237 260 276
kN/m³ 7,5 7,5 7,5 7,5
N/mm² 0,7 0,7 0,7 0,70,75 0,75 0,75 0,75
[mm/m] 0 0 0 010-6K 6 6 6 6
dB ** ** ** **
F 90 A F 90 A F 90 A F 90 A
µ 5 - 10 5 - 10 5 - 10 5 - 10
No./ m³ 54 44 41 37
No./ m² 16 16 16 16
L/m³ 11 11 11 11
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stressFinal creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Ziegel blocks
Thin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 650 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZV10V.PLus
● Thin Bed Insulating Solid Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar & Mesh Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-860
![Page 30: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/30.jpg)
ZV11300F ZV11365F
mm 300 365Dimension Length mm 247 247
Dimension Width mm 300 365
Dimension Height mm 249 249
6 6
kg/m³ 700 700
N/mm² 7,5 7,5
W/mK 0.11 0.11W/m²K 0.33 0.28
kJ/m²K 210 255
kN/m³ 8 8
N/mm² 0,7 0,70,75 0,75
[mm/m] 0 010-6K 6 6
dB ** **
F 90 A F 90 A
µ 5 - 10 5 - 10
No./ m³ 54 44
No./ m² 16 16
L/m³ 11 11Ziegel blocks
Thin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 700 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Final creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Heat storage capacityStructural Properties
Design weight
Permissible compressive stress
Block strength class
Bulk density class
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity
U-value
Natura l Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: info@natura l-building.co.uk web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
● Thin Bed Insulating Solid Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar & Mesh Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-860
NBTZV11V.PLus
![Page 31: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/31.jpg)
ZV12300F ZV12365F ZV12400F ZV12425F ZV12490F
mm 300 365 400 425 490Dimension Length mm 247 247 247 247 37
Dimension Width mm 300 365 400 425 37
Dimension Height mm 249 249 249 249 37
6 6 6 6 37
kg/m³ 650 650 650 650 650
N/mm² 7.5 7.5 7.5 7.5 7.5
W/mK 0.12 0.12 0.12 0.12 0.12W/m²K 0.36 0.3 0.28 0.26 0.23
kJ/m²K 180 219 240 255 297
kN/m³ 7.5 7.5 7.5 7.5 7.5
N/mm² 0.8 0.8 0.8 0.8 0.80.75 0.75 0.75 0.75 0.75
[mm/m] 0 0 0 0 010-6K 6 6 6 6 6
dB ** ** ** ** **
F 30 A F 30 A F 30 A F 30 A F 30 A
µ 5 - 10 5 - 10 5 - 10 5 - 10 5 - 10
No./ m³ 54 44 41 38 33
No./ m² 16 16 16 16 16
L/m³ 11 11 11 11 11
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stressFinal creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Ziegel blocks
Thin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 650 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Natura l Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: info@natura l-building.co.uk web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZV12V.PLus
● Thin Bed Insulating Solid Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar & Mesh Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-698
![Page 32: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/32.jpg)
ZA08115F ZA08175F ZA08240F
mm 115 175 240Dimension Length mm 372 372 372
Dimension Width mm 115 175 240
Dimension Height mm 249 249 249
8 8 8
kg/m³ 800 900 800
N/mm² 10 10 10
W/mK 0.18W/m²K 0.63
kJ/m²K 103 157 192
kN/m³ 10 11 10
N/mm² 1.4 1.4 1.40.75 0.75 0.75
[mm/m] 0 0 010-6K 6 6 6
dB 38 42 45
F 90 A F 90 A F 90 A
µ 5 - 10 5 - 10 5 - 10
No./ m³ 94 62 45
No./ m² 10.7 10.7 10.7L/m³ 6.5 6.5 6.5
Ziegel blocksThin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 800/900 kg/m³ with plaster both sides at 30 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Final creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Heat storage capacityStructural Properties
Design weight
Permissible compressive stress
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Natura l Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: info@natura l-building.co.uk web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZA08INTERNAL
● Thin Bed Solid Internal Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-522
![Page 33: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/33.jpg)
ZA12115F ZA12175F ZA12240F
mm 115 175 240Dimension Length mm 373 373 308
Dimension Width mm 115 175 240
Dimension Height mm 249 249 249
12 12 12
kg/m³ 1200 1200 1200
N/mm² 15 15 15
W/mK 0.50 0.50 0.50W/m²K 1.93 1.57 1.3
kJ/m²K 138 210 288
kN/m³ 13 13 13
N/mm² 1.8 1.8 1.80.75 0.75 0.75
[mm/m] 0 0 010-6K 6 6 6
dB 41 45 49
F 120 A F 180 A F 180 A
µ 5 - 10 5 - 10 5 - 10
No./ m³ 94 62 54
No./ m² 10.7 10.7 13L/m³ 6.5 6.5 6.5
Ziegel blocksThin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 1200 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Final creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Heat storage capacityStructural Properties
Design weight
Permissible compressive stress
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZA12INTERNAL
● Thin Bed Solid Internal Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-407
![Page 34: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/34.jpg)
ZA14115F ZA14175F ZA14240F
mm 115 175 240Dimension Length mm 373 373 308
Dimension Width mm 115 175 240
Dimension Height mm 249 249 249
12 12 12
kg/m³ 1400 1400 1400
N/mm² 15 15 15
W/mK 0.58 0.58 0.58W/m²K 2.43 1.94 1.60
kJ/m²K 161 245 336
kN/m³ 15 15 15
N/mm² 1.8 1.8 1.80.75 0.75 0.75
[mm/m] 0 0 010-6K 6 6 6
dB 45 47 50
F 90 A F 180 A F 180 A
µ 5 - 10 5 - 10 5 - 10
No./ m³ 94 62 54
No./ m² 10.7 10.7 13L/m³ 6.5 6.5 6.5
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stressFinal creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Ziegel blocksThin bed mortar (approx.)
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 1400 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Natura l Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: info@natura l-building.co.uk web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZA14INTERNAL
● Thin Bed Solid Internal Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-407
![Page 35: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/35.jpg)
ZF08145F ZF08175F ZF08200F ZF08240F ZF08300F
mm 145 175 200 240 300Dimension Length mm 372 372 372 372 372
Dimension Width mm 145 175 200 240 300
Dimension Height mm 249 249 249 249 249
8 8 8 8 8
kg/m³ 800 800 800 800 800
kg/m³ 1800 2000 2000 2000 2000
W/mK 0.8 0.8 0.8 0.8 0.8W/m²K 2.13 1.97 1.86 1.7 1.51
kJ/m²K 300 350 400 480 600
kN/m³ 21 21 21 21 21
N/mm² 1.7 1.7 1.4 1.4 1.40.75 0.75 0.75 0.75 0.75
[mm/m] 0 0 0 0 010-6K 6 6 6 6 6
dB 48 51 53 55 58
F 90 A F 120 A F 120 A F 180 A F 180 A
µ 5 - 10 5 - 10 5 - 10 5 - 10 5 - 10
No./ m³ 74 62 54 45 30
No./ m² 10.7 10.7 10.7 10.7 10.7
l/m³ 475 453 530 525 515l/m² 38 79 106 123 152
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Bulk density class (FILLED)
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stress
Water vapour diffusion resistance
Final creep coefficient φ:
Material Quantities
Ziegel blocks
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Backfill concrete B 15 (0-16) with BV
Ziegel blocks
Backfill concrete B 15 (0-16) with BV
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 1900 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTZF08
● Thin Bed Back Filled Party Wall System
● Mortar Free Interlocking Perp Joints
● Block Laying Mortar Included
Block Laying Mortar Included in Block Price.
Conforms To DIBT Certificate Z 17,1-559/583
Plan FullZiegel
![Page 36: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/36.jpg)
U BLOCK WL BLOCK
Block Style WL
Part NumberZA99 115U
ZA99 240U
ZT00 300U
ZT00 365U
ZT00 365WU
ZT00 365WU
ZT00 365WL
Wall thickness mm 175 240 300 365 300 365 365Length mm (L) 240 240 240 240 240 240 240
Width mm (B) 175 240 300 365 300 365 365
Height mm (H) 240 240 240 240 240 240 240
Mean compressive strength N/mm² 8 8 8 8 8
U-value W/m²K 0.37 0.33 0.35
Fire resistance period F 180 A F 180 A F 180 A F 180 A F 180 A F 180 A F 180 A
Vapour diffusion resistance µ 5 - 10 5 - 10 5 - 10 5 - 10 5 - 10 5 - 10 5 - 10
Section Width mm 80 130 180 250 130 170 220
Section Height mm 190 180 180 180 190 180 180
60
145
N/m² *
Permissible Compressive Stress
1.6
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Infill Section Dimensions (for concrete and reinforcement)
Block Flange Dimensions (WL Block Only)
Web Thickness mm (b)
Base Height mm (h2)
WU BLOCK
U WU
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical Data
Basic Properties
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTU, WU,
WL BLOCKS
* U,WU & WL Blocks should be laid on a 10mm bed and pointed with Class III Mortar.
![Page 37: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/37.jpg)
ZT10300F ZT10365F ZT10400F ZT10425F
mm 115 175 300 365mm
mm 71 71 113 113
6 6 6 6
kg/m³ 650 650 650 650
N/mm² 7,5 7,5 7,5 7,5
W/m²K 0.47 0.46
F 180 A F 180 A F 180 A F 180 A
µ 5 - 10 5 - 10 5 - 10 5 - 10
Order 1 x
Order 1 x
Order 2 x
Order 1 x + 1 x
Order 1 x
Order 3 x
Order 2 x
Order 1 x
Order 2 x *
425 thick wall Order 2 x + 1 x
Order 4 x
Order 1 x + 2 x
Lintol Style
** Minimum 125mm Bearing support required on each side of lintol
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
490 thick wall option 2
Lintol Combinations for Various Wall Thickness's
115 thick wall
Fire resistance period ***
175 thick wall
240 thick wall
Water Vapour Transmission
Water vapour diffusion resistance
NBT ThermoPlan Technical DataPart Number
Lintol thickness
Basic PropertiesLintol Height
490 thick wall option 1
Block strength class
Bulk density class
Mean compressive strength
U-value
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
300 thick wall option 1
400 thick wall * 50mm insulation board between
300 thick wall option 2
365 thick wall option 1
365 thick wall option 2
365 thick wall option 3
Availble Lengths ** 1000, 1250, 1500, 1750, 2000, 2250, 2500, 2750
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTPrecast
Lintols
● Precast lintol sections
● Pre-Insulated for External Walls
● Spans upto 2.5m
![Page 38: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/38.jpg)
ZT00300HR ZT00300R ZT00365HR ZT00365R
mm 300 365 400 425Dimension Length mm 123 247 123 247
Dimension Width mm 300 300 365 365
Dimension Height mm 249 249 249 249
6 6 6 6
kg/m³ 600 600 600 600
N/mm² 7,5 7,5 7,5 7,5
W/mK
W/m²K
kJ/m²K 180 180 219 219
kN/m³ 7 7 7 7
N/mm² 1 1 1 10.75 0.75 0.75 0.75
[mm/m] 0 0 0 010-6K 6 6 6 6
dB ** ** ** **
F 90 A F 90 A F 90 A F 90 A
µ 5 - 10 5 - 10 5 - 10 5 - 10
mm 40 40 40 40
mm 115 115 115 115
Block strength class
Bulk density class
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Thermal conductivity (l)
U-value
Heat storage capacityStructural Properties
Design weight
Permissible compressive stressFinal creep coefficient φ:
Checked reveal dimension (in addition to main block length)
Width
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
Depth
external wall with 20 mm lightweight external render and 10 mm lime-gypsum internal plasterThermal Performance
Calculation for a wall with density 650 kg/m³ with plaster both sides at 40 kg/m²Acoustic Performance**
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Water Vapour Transmission
Water vapour diffusion resistance
Natural Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: [email protected] web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTReveal Blocks
● Stepped Reveal for excellent Airtightness
● Mortar Free Interlocking Perp Joints
● Full & Half Width to Maintain Bond
Block Laying Mortar Included in Block Price.
![Page 39: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/39.jpg)
ZA99240A ZT00300A ZT00365A
mm 240 300 365Dimension Height mm 249 249 249
8 8 8kg/m³ 800 800 800
N/mm² 7.5 7.5 7.5
W/mK
W/m²K
kJ/m²K
kN/m³ 8 8 8N/mm² 0.8 0.8 0.8
1 1 1
[mm/m] 0 0 0
10-6K 6 6 6
dB
F 120 A F 180 A F 180 A
µ 5 - 10 5 - 10 5 - 10
NBT
The
rmo
pla
n® Z
ieg
el -
Te
chn
ica
l Da
ta
Acoustic Performance**
U-value
Thermal conductivity (l)
external wall with 20 mm lightweight external render and 10 mm lime gypsum internal plasterThermal Performance
Heat storage capacityStructural Properties
Design weight
Water Vapour Transmission
Water vapour diffusion resistance
Final creep coefficient φ:
Long-term moisture movementCoefficient of thermal expansion α
Sound insulation R'w, R (DIN 4109)
Fire resistance period ***
with thin joint mortar according to certification, both sides rendered with Group P IV mortars in accordance with DIN 18550 - 2Fire Resistance
Calculation for a wall with density 1200 kg/m³ with plaster both sides at 40 kg/m²
Permissible compressive stress
Block strength classBulk density class
NBT ThermoPlan Technical DataPart Number
Wall thickness
Basic Properties
Mean compressive strength
Natura l Building Technologies LtdThe Hangar Worminghall Road Oakley Bucks HP18 9ULTel: +44 (0)1844 338338 Fax: +44(0)1844 338525email: info@natura l-building.co.uk web: www.natural-building.co.uk
NBT ThermoPlan ® Ziegel Blocks
NBTAngle Block
● 135° / 45° Angle Block
● Mortar Free Interlocking Perp Joints
● BlockDesign Maintains Bond
Block Laying Mortar Included in Block Price.
![Page 40: Thermo Plan Manual Zeigle Blocks](https://reader033.vdocuments.mx/reader033/viewer/2022052321/551fb3dc497959d9398b5597/html5/thumbnails/40.jpg)