AERIAL LIFT TEST SETSMODELS (BK60, BK130, BK130-1)
60206HIGH REL IAB IL I TY AND RUGGED , L IGHTWEIGHT PORTABIL I TY
PHENIX 130kV Model BK130
Description
PHENIX TECHNOLOGIES manufactures three models of Aerial Lift Test Sets. The and
These units are designed specifically for AC dielectric testing in accordance with the latest and upcoming ANSI A92.2 draft standards.
The is the most economical solution for boom testing on distribution level devices.
The is the more powerful unit with output current sufficient to test both the elevating boom as well as the insulated work platform and linings.
For those performing testing that requires transmission and distribution level boom testing but not lining testing, the
is the more economical choice. These units can also be used in many other testing
situations calling for AC dielectric and insulation testing. Designed for full portability, these test sets are mounted on
a rugged two-wheel cart (except ) and consist of: High voltage transformer Control Unit Interconnect cables
When testing, the high voltage transformer is removed from the cart and placed close to the test object. The cart with the control box can then be moved away from the test area for the operator�s safety.
BK60, BK130BK130-1.
BK60
BK130
BK130-1
BK60l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Internal Voltage dividers for all unitsControls in a removable enclosure, grounded through the power cord with provisions for a separate ground cableCircuit breaker for control power, combined with EMERGENCY OFF pushbuttonGuard mode for accurate current measurements External interlock provision ZERO START interlockOverload circuit, adjustable from 10% to 110% of rated output currentBK130�s have a backup overload protection in the supply circuit CONTROL POWER ON indicatorHV ON/OFF pushbuttons with indicator Manual control of output voltageResettable OVERLOAD indicator 20 ft. (6m) interconnect cables between controls and high voltage unit Grounding studs on control panel and high voltage transformer. 20 ft. (6 m) ground and return leads Cable storage provisionTwo copies of Operation/ Maintenance Manual Optional cart mounted, telescoping red flashing light high voltage warning indicator
Optional Accessory Package includes: 1 HV Output cable 50' 1 Return Cable 50' 1 Upper Boom Cable, 50' 3 5' Jumper Leads 1 Foot Switch, 30' Lead or 50' lead
(hand switch also available) 1 A92.2 (latest revision) Standard 8 2' x 2' x 3/8" Insulating Pads
The high voltage transformers are oil-filled, insulating cylinders mounted on a steel base. The high voltage output is available from a toroid on top of the cylinder. The BK130 also utilizes a 35kV side output tap for liner testing.
The voltage regulator is an adjustable autotransformer, air-insulated with a limit switch for �zero start� interlock. All units are equipped with a high accuracy internal divider. The low voltage arm of the divider feeds the panel-mounted voltmeter. Total measuring accuracy is better than 1% of full scale from 10%-100% of range.
The lower end of the high voltage winding is connected to ground through a currentmeter circuit. Measuring accuracy is better than 1% of full scale. A return terminal provides precise measurement of actual current flow through the test object to guard out capacitive leakage currents (guard mode).
An adjustable electronic overload circuit, with a total response time of less than 30 milli-seconds, provides protec-tion from flashovers and short circuits for the high voltage transformer and for the test object.
Cover photos: Courtesy of Allegheny Power
Accessory Package
120 volts, 10 amps, 50-60 Hz, single phase or 120 volts, 30 amps, 50-60 Hz, single-phase or 120 volts, 15 amps, 50-60 Hz, single phase
220 volts, 6 amps, 50-60 Hz, single phase 220 volts, 15 amps, 50-60 Hz, single phase 220 Volts, 8 amps, 50/60 Hz, single phase
0-60kVAC, 10mA 0-130kVAC @ 50mA, and 0-130kVAC @ 11.7mA
0-35kVAC @171 mA
1 hour ON/ 1 hour OFF @ 7mA 1 hour ON/ 1 hour OFF @ 33.3mA/114mA 1 hour ON/ 1 hour OFF @ 8.33mA
5 min. ON/ 15 min. OFF @ 10mA 5 min. ON/ 15 min. OFF @ 50mA/171mA 5 min. ON/ 15 min. OFF @ 11.7mA
Continuous @ 5mA Continuous @ 25mA/86mA Continuous @ 5.6mA
Single range digital with accuracy Double range digital with accuracy Single range digital with accuracy
of 1% of reading from 12-60kV of 1% of reading: 12-35kV, 12-130kV of 1% of reading from 12-130kV
Range: 0-60kVAC Range: 0-35kVAC, 0-130kVAC Range: 0-130kVAC
Triple-range digital with accuracy +/- 1% F.S. Quadruple range digital with accuracy +/- 1% F.S. Triple-range digital with accuracy +/- 1% F.S.
Range: Three range 0-200uA, 2mA, 20mA Range: Four-range 0-200uA/2mA/20mA/200mA Range: Three range 0-200uA, 2mA, 20mA
23" W x 27" D x 46.25" H; 166 lbs. 23" W x 27" D x 48" H; 300 lbs. 23" W x 27" Dx 48" H; 230.5 lbs.
(584mm) (686mm) (1175mm); (105.7kg) (584mm) (686mm) (1220mm); (136kg) (584mm) (686mm) (1220mm); (104.6kg)
14" W x 14" D x 14" H; 70 lbs. 16" W x 16" D x 30" H; 178 lbs. 15" W x 16"D x27" H; 132 lbs.
(356mm) (356mm) (356mm); (32kg) (406mm) (405mm) (762mm); (80.7kg) (381mm) (407mm) (686mm); (59.9kg)
16.5" W x 15.25" D x 11.25" H; 35 lbs. 21.5" W x 17" D x 14" H; 45 lbs. 21.5" W x 17" D x 14" H; 40 lbs.
(420mm) (390mm) (285mm); (15.9kg) (564mm) (426mm) (350mm); (20.4kg) (564mm) (432mm) (350mm); (18.2kg)
OPTIONAL 22.5" W x 29.5" D x 46.5" H; 61 lbs 22.5" W x 29.5" D x 46.5" H; 61 lbs.
22.5" W x 29.5" D x 46.5" H; 61 lbs. (572mm) (750mm) (1180mm); (27.7 kg) (572mm) (750mm) (1180mm); (27.7 kg)
(572mm) (750mm) (1180mm); (27.7 kg)
Model BK60 BK130 BK130-1
Input
Output
Duty
Voltmeter
Currentmeter
Dimensions
Complete Unit
High Voltage
Control Box
Cart
*Based on our commitment to continual research and development PHENIX Technologies reserves the right to update product specification without notice.
(with optional cart)
Transformer
BK130 controls with digital metering
Your local representative is
116 Industrial DriveAccident, MD 21520 USA
Tel: 301-746-8118Fax: 301-895-5570
http://www.phenixtech.com8/02
The PHENIX Technologies Product Line
Models BK60 BK130 BK130-1
Category A&B Devices Perodic Test
46kV & Below Voltage Class Yes Yes Yes
69kV Voltage Class Yes Yes Yes
138kV Voltage Class No Yes Yes
Category C Devices Perodic Test
46kV & Below Voltage Class Yes Yes Yes
Insulating Aerial Ladders and
Insulating Aerial Vertical Towers
Perodic Test
46kV & Below Yes Yes Yes
20kV & Below Yes Yes Yes
Category A&B Devices
50/60 Hz Qualification Test
46kV & Below Voltage Class Yes Yes Yes
69kV Voltage Class Yes Yes Yes
138kV Voltage Class No Yes Yes
Category A&B Devices
Double Rated Voltage Test
46kV & Below Voltage Class Yes Yes Yes
69kV Voltage Test No Yes Yes
Category C Qualification Test
46kV & Below Voltage Class No Yes Yes
Insulating Aerial Ladders and
Insulating Aerial Vertical Towers
Qualification Test
46kV & Below No Yes Yes
20kV & Below Yes Yes Yes
l
l
l
l
l
l
l
l
l
l
l
AC Dielectric Test SetsResonant Test SetsDC Hipots and Insulation Test SetsAutomatic Insulating Material Testers (Dl49)Liquid Dielectric Test SetsMegohmmetersVacuum/Oil Interrupter TestersBucket Truck TestersHigh-Frequency Cable Aging Test SetsHeat Cycling Test SetsRubber Goods�Protective Equipment Testers
l
l
l
l
l
l
l
l
l
l
l
Core Loss TestersAC, DC and AC/DC Motor Test SetsTransformer Test SystemsComputerized Circuit Breaker Test SetsComputerized Recloser Test SetsDC Power SuppliesHigh Voltage DC Cable ThumpersHigh Voltage TerminationsHigh Power Column-Type Variable TransformersHigh Power Thoma-Type Variable TransformersVoltage and Current Stabilizers
PHENIX Model BK130-1(with optionalred highvoltage light)
PHENIX Model BK60