test report 139797 / 1 finvest-corp d.d. pilanska 7 hr - …€¦ · test report 139797 / 1 date...
TRANSCRIPT
TEST REPORT
139797 / 1Date received: 21-03-12Date of test: 05-04-12Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
Determination of moisture content UNI EN 14774-3:2009
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
Sampling:
N.
Carry out by the customer
9,9999999999996E-05
tara tara+campione tara + secco
Temperature: 103±2 °C
Heating period: 12 h
Test results:
Moisture %
Note: The test result is reported on a wet basis.
1 7,00 16,205 27,4904 26,7001
2 6,93 0,0036000000000001 15,8562 26,0741 25,366
3 7,03 0,0016 11,2531 22,3612 21,58
Mean value 6,99 0,0053000000000001
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
139797 / 2Date received: 21-03-12Date of test: 05-04-12Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
Determination of ash content UNI EN14775:2010
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
Sampling:
N.
Carry out by the customer
Ash on dry basis
(%)
0,7396
TARA TARA + CAMPIONETAL QUALE
TARA + CAMPIONESECCO TARA + CENERI
temperature: 550 ± 20 °C
Moisture content: 5,10 %
Apparatus: Furnace
Test result:
Ash on wet basis
(%)
1 0,85 0,90 16,205 27,4904 26,9148446 16,301
2 0,82 0,86 15,8562 26,0741 25,5529871 15,94
3 0,83 0,87 0,7569 11,2531 22,3612 21,7946869 11,345
0
Mean value 0,83 0,8810 16 15
10 16 10
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
139797 / 3Date received: 21-03-12Date of test: 05-04-12Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
Determination of calorific value UNI EN 14918:2010
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
Sampling:
Moisture content:
Carry out by the customer
Net calorific valueon wet basis
MJ/kg
Temperature: 103±2 °C per 12 ore
Apparatus: Isoperibol calorimeter.
Test result:
6,99 %
Note:
N.Gross calorific value
on dry basisMJ/kg
1 20,08 17,3
2 19,86 17,1
3 19,45 16,7
Mean value 19,80 17,0
1 cal x 4,1868 = 1 J
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
139797 / 4Date received: 21-03-12Date of test: 05-04-12Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
Determination of bulk density CEN/TS 15103:2005
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
Moisture: 7,0 %
Bulk densitykg/m3
0
Volume of container: 4,96 litres
Test result:
Sample massgN°
1 3105,3 626
2 3085,6 622 0
Note:
Mean 624 0
The test was carried out on the sample as received.
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
139797 / 5Date received: 21-03-12Date of test: 05-04-12Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
Determination of durability CEN/TS 15210-1:2006
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
Test result
Moisture: 6,99 %
Durability%
9643,24
Amount of fines:
0,37 %N. 1
N. 2 0,02 %
Sample massbefore tumbling
g
Sample massafter tumbling
gN.
1 500,6 491,8 98,2
2 501,0 492,1 98,2 9643,24
Note:
Mean 98,2 19286,48
The test was carried out on the sample as received.
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
139797 / 6Date received: 21-03-12Date of test: 05-04-12Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
Metals determination by atomic absorption - CATAS procedure
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
SAMPLE PREPARATION
mg/kg
VALUE Metallo
peso ceneri g 0,2018
Ass. CAMPml
Diluizione
Direct attack of the sample with concentrated nitric acid by microwaveoven
TECHNIQUE USEDInductively coupled plasma optical spectrometry (ICP-AES) ceneri % ss 2,8
Peso camp g
TEST RESULTS
2,0512
mg/lAss. STD
The following value are referred to dry sample.
ELEMENT Conc. STD Volume
ARSENIC < 0,1 As 0,02 2,2 0,41 25 2
LEAD mg/kg < 5 Pb 4 0,126 0,008 50 1
CADMIUM mg/kg < 0,5 Cd 0,196 0,034 0,002 50 1
MERCURY mg/kg < 0,1 Hg 0,02 0,41 0 25 1
COPPER mg/kg < 5 Cu 1,99 0,138 0,018 50 10
CHROMIUM mg/kg < 5 Cr 2,05 0,081 0,01 50 1
ZINC mg/kg < 5 Zn 0,4 0,153 0,136 50 10
SODIUM % 0,002 Na
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove
settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
TECHNICAL REPORT n°: 139797 / 7 del 05/04/12
Date received: 21-03-12
Date of test: 05-04-12
Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
Determination of Nitrogen, Chlorine and Sulphur - CATAS procedure
ANALYTICAL METHOD
Chlorine and Sulphur: Oxygen combustion, absorption in alcaline/hydrogen
peroxide solution and turbidimetric analysis.
Total Nitrogen: Kjeldahl Method.
Test carried out on dry speciments.
RESULTS
ELEMENT Units VALUE
Chlorine (Cl) % s.s. 0,02
Sulphur (S) % s.s. 0,01
Total Nitrogen (TKN) % s.s. 0,16
page 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon
TEST REPORT
139797 / 8Date received: 21-03-12Date of test: 05-04-12Date of issue: 05-04-12
Sample name: FINPELLETS - FINVESTCORP
Formaldehyde content - EN 120:1992
FINVEST-CORP D.D.!PILANSKA 7!51304 GEROVO!HR - CROAZIA
CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.
centro ricerche-sviluppo e laboratori prove settori legno-arredo, ambiente e alimenti
Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]
Filiale: Via Braille, 5 20851 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]
Diameter mm 6,0Moisture content % 1,0Conditioning - Not requested by the customerSampling - Carried out by the customerReceived sample description - 15 kg sack
Test results
mgHCHO/100g (dry sample) 0,4
Material Pellet
pag. 1/1
The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.
This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.
Managing Director Dr. Andrea Giavon