Capacity : 50 to 400 kg per load C C C M M M T T T S S S TM CMTS Mobile Mixed Waste Incinerator Emission Test Report C C M M T T S S C C C M M M T T T S S S TM TEST METHOD PARAMETER / TEST DESCRIPTION Unit Detection Limit STD C* Limit Results USEPA Method 26A 1. Chlorine Gas gm/Nm³ 0.01 0.2 < 0.1 USEPA Method 5 2. Dust gm/Nm³ 0.001 0.4 0.1 ASTM D-3211 3. Dark Smoke Emission Ringelmann - 1 0 USEPA Method 29 Metals in Air BY ICP- AES 4. Antimony, Sb gm/Nm³ 0.001 0.025 <0.001 5. Cadmium, Cd gm/Nm³ 0.001 0.015 <0.001 6.Copper, Cu gm/Nm³ 0.001 0.100 <0.001 7. Lead, Pb gm/Nm³ 0.001 0.025 <0.001 8. Zinc, Zn gm/Nm³ 0.001 0.100 <0.001 USEPA Method 29 Isokinetik Arsenic : AA – FIAS 9. Arsenic, As gm/Nm³ 0.001 0.025 <0.001 USEPA Method 29 Isokinetic Mercury : AA – FIAS 10. Mercury, Hg gm/Nm³ 0.001 0.010 < 0.001 Gas Analyser 11. Hydrogen Sulphide (H2S) ppm 0.1 5 < 0.1 USEPA Method 26A Acids by Ion Chromatography 12. Sulfuric Acid (H2SO4) gm/Nm³ 0.01 0.2 < 0.01 13. Hydrochlorine Acid (HCL) gm/Nm³ 0.01 0.4 0.012 14. Hydrofluoric Acid (HF) gm/Nm³ 0.01 0.1 <0.01 Gas Analyser 15. NOX as NO2 gm/Nm³ 0.01 2 <0.01 16. SO2 gm/Nm³ 0.01 2 < 0.01 MALAYSIA No.9, Jalan TPP 5/13, Taman Perindustrian Puchong, 47100 Puchong, Selangor, MALAYSIA Tel : +603-80623686 Fax :+603-80623680 E-mail : [email protected] Website : www.cmtsproduct.com NETHERLANDS Koningstraat 99, 6651 KK Duten, The Netherlands. Tel : +31 (0) 487 514838 Fax : +31(0) 487 515236 E-mail : [email protected] W e b s i t e : http://www.cmtsproduct.com Copyright © 2013 CMTS Sdn Bhd. All Rights Reserved Note : 1. < = Less Than or Below Detection Limit 2. STD C Limit = Malaysia Environmental Quality (Clean Air) Regulations, 1978, Standard C Methodology Sampling and analysis was carried out as per American Society for Testing and Materials & USA Environmental Protection Agency (EPA) Code of Federal Regulations 40 Part 60. Methods Description ASTM D-3211 Determination of Concentration and flow of particulate Matter in Flue Gas Gas Analyzer Determination of Nitrogen Oxide from stationary sources USEPA Method 5 Determination of particulate matter emissions from stationary sources USEPA Method 26A Determination of Hydrochloric Acid & Chlorine Gas from stationary sources USEPA 29 Determination of metals from stationary sources Garbage Illicit / Expired Drugs Deceased Animals

Upload: others

Post on 17-Feb-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TEST DESCRIPTION Limit Mobile Mixed Waste Incinerator · Chamber Volume MACI 100 MACI 200 MACI 500 Primary Chamber m3 1.15 2.25 3.74 6 Secondary Chamber m3 0.86 1.54 2.87 4.6 Charging

Capacity : 50 to 400 kg per load

CCCMMMTTTSSSTM

CMTSMobile Mixed Waste Incinerator

Emission Test ReportCCCMMMTTTSSS

CCCMMMTTTSSSTM

TEST METHOD PARAMETER /TEST DESCRIPTION

Unit DetectionLimit

STD C*Limit

Results

USEPA Method 26A 1. Chlorine Gas gm/Nm³ 0.01 0.2 < 0.1USEPA Method 5 2. Dust gm/Nm³ 0.001 0.4 0.1ASTM D-3211 3. Dark Smoke Emission Ringelmann - 1 0

USEPA Method 29 Metals in Air BY ICP- AES4. Antimony, Sb gm/Nm³ 0.001 0.025 <0.0015. Cadmium, Cd gm/Nm³ 0.001 0.015 <0.0016.Copper, Cu gm/Nm³ 0.001 0.100 <0.0017. Lead, Pb gm/Nm³ 0.001 0.025 <0.0018. Zinc, Zn gm/Nm³ 0.001 0.100 <0.001

USEPA Method 29 Isokinetik Arsenic : AA – FIAS9. Arsenic, As gm/Nm³ 0.001 0.025 <0.001

USEPA Method 29 Isokinetic Mercury : AA – FIAS10. Mercury, Hg gm/Nm³ 0.001 0.010 < 0.001

Gas Analyser 11. Hydrogen Sulphide (H2S) ppm 0.1 5 < 0.1

USEPA Method 26A Acids by Ion Chromatography12. Sulfuric Acid (H2SO4) gm/Nm³ 0.01 0.2 < 0.0113. Hydrochlorine Acid (HCL) gm/Nm³ 0.01 0.4 0.01214. Hydrofluoric Acid (HF) gm/Nm³ 0.01 0.1 <0.01

Gas Analyser 15. NOX as NO2 gm/Nm³ 0.01 2 <0.0116. SO2 gm/Nm³ 0.01 2 < 0.01

MALAYSIA

No.9, Jalan TPP 5/13, Taman Perindustrian Puchong, 47100 Puchong, Selangor, MALAYSIA● Tel : +603-80623686 ● Fax :+603-80623680● E-mai l : sa les@cmtsproduc t .com ● Webs i te : www.cmtsproduc t .com

NETHERL ANDS

Kon ings t raa t 99 , 6651 KK Duten , The Nether lands .● Tel : +31 (0) 487 514838 ● Fax : +31(0) 487 515236● E-mai l : sa les@cmtsproduc t .com ● Webs i te :http://www.cmtsproduct.com

Copyright © 2013 CMTS Sdn Bhd. All Rights Reserved

Note :1. < = Less Than or Below Detection Limit2. STD C Limit = Malaysia Environmental Quality (Clean Air) Regulations, 1978, Standard C

Methodology

Sampling and analysis was carried out as per American Society for Testing and Materials & USA Environmental Protection Agency (EPA) Code of Federal Regulations 40 Part 60.

Methods Description

ASTM D-3211 Determination of Concentration and flow of particulate Matter in FlueGas

Gas Analyzer Determination of Nitrogen Oxide from stationary sources

USEPA Method 5 Determination of particulate matter emissions from stationary sources

USEPA Method 26A Determination of Hydrochloric Acid & Chlorine Gas from stationarysources

USEPA 29 Determination of metals from stationary sources

Garbage

Illicit / Expired Drugs

Deceased Animals

Page 2: TEST DESCRIPTION Limit Mobile Mixed Waste Incinerator · Chamber Volume MACI 100 MACI 200 MACI 500 Primary Chamber m3 1.15 2.25 3.74 6 Secondary Chamber m3 0.86 1.54 2.87 4.6 Charging

y s a y ithout

Layout Plan

STANDARDSPECIFICATIONModel MACI 100 MACI 200 MACI 500Type Controlled Air Technology, Double Chamber DesignBurning rate (kg/hr) 50 100 200 500Batch Load (kg) 200 400 800 2000

Chamber Volume MACI 100 MACI 200 MACI 500Primary Chamber m3 1.15 2.25 3.74 6Secondary Chamber m3 0.86 1.54 2.87 4.6Charging / Clean out Door Diameter (metres) 1.1 1.25 1.33 1.63

Construction (Temperature of Refractory Castable) MACI 100 MACI 200 MACI 500Primary Chamber Wall/Floor 1400 deg C 1400 deg C 1400 deg C 1400 deg CSecondary Chamber Wall/Floor 1600 deg C 1600 deg C 1600 deg C 1600 deg CStack Insulation 1200 deg C 1200 deg C 1200 deg C 1200 deg C

Burner Type MACI 100 MACI 200 MACI 500Primary Burner Capacity (kcal/hr) 125,000 125,000 250,000 500,000Secondary Burner Capacity (kcal/hr) 250,000 250,000 375,000 700,000Packaged Burner Type (Standard) ECOFLAM ECOFLAM ECOFLAM ECOFLAMIndustrial Nozzle Mix Type (Optional) MAXON/HOPE MAXON/HOPE MAXON/HOPE MAXON/HOPE

Temperature Controls MACI 100 MACI 200 MACI 500Primary & Secondary Chamber FUJI / OMRON FUJI / OMRON FUJI / OMRON FUJI / OMRONBurner interface, status, reset access Yes Yes Yes YesSystem status alarm display Yes Yes Yes YesPLC (optional) OMRON/ SIEMENS OMRON/ SIEMENS OMRON/ SIEMENS OMRON/ SIEMENS

MACI 50

MACI 50

MACI 50

MACI 50

MACI 50

Disclaimer : CMTS may make changes to these specification at anytime without prior notice.

w w w . c m t s p r o d u c t . c o m

Mobile Mixed Waste Incinerator ~ Specification

GENERAL

This incinerator is designed for the destruction of combustible waste generated from Customs, Immigration and Quarantine Centres include Pharmaceutical Items, Drugs, DVDs / VCDs, lllegal Books, Magazines, Plant & Vegetable, Deceased Animals and etc.

The "PYROLYTIC GASIFICATION" process involves the controlled combustion of waste under substoichiometric condition.

Prevents :

The development of black smoke and formation of fine dust when waste loadings.

It enables :

A regular and complete waste combustion.

Its advantages are as follows :

A controlled combustion providing the absence of coloured, dust covered or odorous smokes.

An automatic operation that does not need any surveillance.

A limited fuel consumption.

The incinerators with "PYROLYTIC" combustion essentially include :

1°) One waste combustion chamber.

One perfectly impervious door for manual or automatic (optional) waste loading.

One ignition burner whose use is limited to waste ignition.

2°) A waste gas secondary (post-combustion) chamber.

One waste gas combustion burner, of low power,

One air injection device enabling a complete gas recombustion,

One air admission device for cooling burnt waste gas,

One burnt waste gas exhaust duct

3°) One PLC process control panel that monitors and control the complete combustion cycle.

4°) Flue Gas Treatment Dry Lime Scrubber

One Dry Scrubber to absorb SO2 and HCL,

One spray injection system to inject atomized lime slurry in a vessel,

One air admission device for cooling burnt waste gas,

One burnt waste gas exhaust duct

Disclaimer : CMTS may make changes to these specifications at any time without prior notice.