Moulded Case Circuit Breakers & Accessories
Terasaki Short Form Catalogue
Air Circuit Breakers & Accessories
2010/2011
β’ The compact 125A size offers the same features and performance but with reduced dimensions and cost.β’ The mechanical interlock is installed on the front of the MCCB, and is compatible with motor operators and handles. An automatic changeover system can be assembled in a few minutes by a switchboard builder or end-user.β’ Under the heading βMeasures to minimise the risk in the event of failureβ. IEC 60204-1 Safety of Machinery-Electrical Equipment Machinery includes the following recommendation: βthe use of the switching devices having positive (or direct) opening operationβ.β’ Overload protection is adjustable between 63% and 100% of the rating.β’ Short-circuit protection is adjustable on all thermal magnetic models.β’ Short-circuit protection settings are suitable for motor starting on all models, including the compact 125A frame.β’ If you require a characteristic which is not available as a preset on our electronic protection unit, send us the details and we will program a customised characteristic to your application. (Within certain limites - contact us for details).β’ Coloured indicators display the 'ON' or 'OFF' status. The indicators are fully covered if the breaker trips, and black is the only visible colour.
β’ Accessories can be fitted by the switchboard builder or added by the end-user. All internal accessories are common for TemBreak2 MCCBs.β’ External operating handles and motor operators can be rapidly fitted using the locking pegs. It takes less than 10 seconds to secure a handle or motor to the MCCB - a great time saving compared to alternative products.β’ All accessories are endurance tested to the same level as the host MCCB.β’ The plug-in MCCB is locked to the base when the toggle is ON. It cannot be removed unless the toggle is OFF or TRIPPED The safety lock prevents a trip occurring as the MCCB is being removed from the base.β’ Door cutout patterns for handles are symmetrical, even when breakers are mounted in opposite directions.β’ All TemBreak2 MCCBs are fully rated for use at 50ΛC.β’ Overheating is the most common cause of failure in electrical switchgear. You can reduce the likelihood of overheating by using switchgear with superior temperature performance.β’ All current ratings up to 630A can be supplied in 2 sizes: the 250A and 630A sizes.
Moulded Case Circuit Breakers& Accessories
A211001080A211001083A212001046
U212002071S212002010H211005386
A211001105A211001106A211001107
U211002347S211002339H211005387
A211001108A211001109A211001110
βS211002348H211005388
A212001004A212001069A212001041
U211002074S211002013H211005389
Auxiliary Switch Alarm ContactShunt Release Under Voltage ReleaseDoor MountHandle IP54
ACCESSORIES
Dimensions h d1 d2 w Max depth with VDH
Ecoplus β fixed settingsEP100-NF EP125-NF EP250-NF EB400-NFβ β β β
3-Pole4-Pole
FIXED MCCBsRCC Cert. 0808103
130mm68mm87mm75mm547mm
155mm68mm86mm90mm547mm
160mm60mm83mm105mm543mm
260mm103mm131mm140mm482mm
550V16kA7.5kAFixed InFixed 13-15 x In
Ratings: Ui 690V Ue AC Breaking Capacity Icu 400V 500VOverload Protection: Thermal Magnetic (Inst.)
690V30kA12kAFixed InFixed 13 x In
550V18kA10kAFixed InFixed 10-11 In
690V35kA22kAFixed InFixed 13 x In
Calibrated for ambient -5 to +50Β°C
16A 50A25A 63A32A 80A40A 100A
125A 160A200A225A250A
300A350A400A
Current RatingIn
EP100-NN EP250-NN EB400-NN
100A550V2.5kA1.8kA
130mm70mm68mm
EP100-NF
250A550V5.5kA3kA
160mm105mm
60mm (68 option)EP250-NF
400A690V9kA5kA
260mm140mm103mm
EB400-NF
3 Pole EP125-NN
125A690V2.5kA1.8kA
155mm90mm68mm
EP125-NF
ISOLATORS
RatingsRated Current AmpsRated Voltage Ue ACRated short circuit making capacity PeakRated short time current 1 secondDimensions h w d For accessories
Auxiliary Switches
Undervoltage Trips InstShunt TripDoor Mount Handle IP54
EP100-NF EP250-NF EB400-NFEP125-NFAux Alarm1C/O 1C/O1C/O 1C/O
240VAC 240VAC
3A @ 250V0.4A @ 500V
w d2d1
h
w d2d1
h
1
E125-NJ E250-NJ E400-NJE125-NJ4 E250-NJ4 E400-NJ4
3-Pole4-Pole
36kA - Adjustable settingsS125-NJ S160-NJ S250-NJ S400-CJ
160A(100-160)
200A (126-200)250A (160-250)
400A(250-400)
Nominal Current Ratings-5 to 50Β°C2000m
690V36kA22kA0.63-1 x In6-12 x In
Ratings: Ui 800V Ue Icu 400/415V Icu 525VProtection: Thermal Magnetic
690V36kA25kA0.63-1 x In6-13 x In
690V36kA25kA0.63-1 x In6-13 x In
690V36kA22kA0.63-1 x In6-12 x In
Dimensions h d1 d2 w-3P w-4P Panel depth with VDH
155mm68mm92mm90mm120mm543mm
165mm68mm92mm105mm140mm543mm
165mm68mm92mm105mm140mm543mm
260mm103mm145mm140mm185mm610mm
S125-NJ4 S160-NJ4 S250-NJ4 S400-CJ43-Pole4-Pole
E630-NE
630A(250-630)
690V36kA15kA
Electronic
260mm103mm145mm140mm185mm610mm
E630-NE4
Nominal Current Ratings -5 to 50Β°C 2000m
525V25kA8kA0.63-1 x In6-12 x In
525V25kA10kA0.63-1 x In6-13 x In
500V25kA15kA0.63-1 x In6-12 x In
155mm68mm92mm90mm120mm543mm
165mm68mm92mm105mm140mm543mm
260mm103mm145mm140mm185mm610mm
50kA - Adjustable settingsS400-NJ S630-CE XS800-NJ
400A (250-400) 630A (250-630) 800A (500-800)Nominal Current RatingsS & E: -5 to 50Β°C2000mXS: -5 to 40Β°C2000m
690V50kA30kA0.63-1 x In6-12 x In
Ratings: Ui 800V Ue Icu 400/415V Icu 525VProtection: Thermal Magnetic
690V50kA30kA
Electronic
690V50kA35kA0.63-1 x In6-10 x In
Dimensions h d1 d2 w-3P w-4P Max Panel depth with VDH
260mm103mm145mm140mm185mm610mm
260mm103mm145mm140mm185mm610mm
273mm103mm145mm210mm280mm484mm
S400-NJ4 S630-CE4 XS800-NJ43-Pole4-Pole
XS1250-CE
1250A (630-1250)
690V50kA35kA
Electronic
370mm120mm171mm210mmβ515mm
β
ADJUSTABLE MCCBs25kA - Adjustable settings
Dimensions h d1 d2 w-3P w-4P Max Panel depth with VDH
E125-NJ
Dimensions
S125-NJ
Dimensions
S400-NJ
Dimensions
RCC Cert. 0808103/0805030
20A (12.5-20)32A (20-32)50A (32-50)63A (40-63)100A (63-100)125A (80-125)
250A(160-250)
400A(250-400)
Ratings: Ui 800V Ue Icu 400/415V Icu 525VProtection: Thermal Magnetic
20A (12.5-20)32A (20-32)50A (32-50)63A (40-63)100A (63-100)125A (80-125)
w d2d1
h
w d2d1
h
w d2d1
h
2
85kA - Adjustable settingsXS1250-SE XS1600-SE XS2000-NE
1250A (630-1250) 1600A (800-1600) 2000A (1000-2000)Nominal Current Ratings-5 to 50Β°C2000m
690V65kA45kA
Electronic
Ratings: Ui 800V Ue Icu 400/415V Icu 525VProtection: Thermal Magnetic
690V85kA65kA
Electronic
690V100kA65kA
Electronic
Dimensions h d1 d2 w-3P w-4P Max panel depth with VDH
370mm120mm171mm210mmβ515mm
370mm140mm191mm210mmβ535mm
450mm225mm285mmββ320 mm
XS1250-SE4 XS1600-SE4 β3-Pole4-Pole
65kA - Adjustable settings
Nominal Current Ratings-5 to 50Β°C2000m
155mm68mm92mm90mm120mm543mm
165mm68mm92mm105mm140mm543mm
165mm68mm92mm105mm140mm543mm
260mm103mm145mm140mm185mm610mm
S125-GJ4 S160-GJ4 S250-GJ4 S400-GJ4S125-GJ S160-GJ S250-GJ S400-GJ S630-GE
260mm103mm145mm140mm185mm610mm
S630-GE4
690V65kA25kA0.63-1 x In6-12 x In
690V65kA25kA0.63-1 x In6-13 x In
690V65kA25kA0.63-1 x In6-13 x In
690V70kA30kA0.63-1 x In6-12 x In
690V70kA30kA
Electronic
ADJUSTABLE MCCBsRCC Cert. 0808103/0805030
3-Pole4-Pole
Ratings: Ui 800V Ue Icu 400/415V Icu 525VProtection: Thermal MagneticDimensions h d1 d2 w-3P w-4P Panel depth with VDH
XS1250SE
Dimensions
S250-GJ
Dimensions
General Purpose Auxiliary SwitchGeneral PurposeAlarm Switch
Heavy Duty Alarm Switch
Heavy Duty Auxiliary Switch
Shunt Trip
Undervoltage
OROR
1) Front Mounting field - Installable Accessories2) Inernal Accessories are common for TemBreak2 (20 - 630Amp)
160A (100-160) 200A (126-200)250A (160-250)
400A(250-400)
630A (250-630)20A (12.5-20)32A (20-32)50A (32-50)63A (40-63)100A (63-100)125A (80-125)
w d2d1
h
w d2d1
h
3
AC100 - 120V U001208 U001208 U001208 U215002067 U212002068AC200 - 240V U001215 U001215 U001215 U215002075 U212002076AC380 - 450V U001222 U001222 U001222 β βDC 24V U001239 U001239 U001239 β β100 - 120V β β β U215002119 U212002120200 - 240V β β β U215002127 U212002128Other voltages available ex-indent
Auxiliary Switches
Alarm Switches
Shunt Trips
Undervoltage Trips
General purpose
Heavy Duty
General purpose
Heavy Duty
125 - 630A 800 - 1600A
AC100 - 120V S000904 S000904 S000904 S211002006 S212002007AC200 - 240V S000911 S000911 S000911 β βAC200 - 480V β β β S215002014 S121002015AC380 - 450V S000928 S000928 S000928 β S212002015DC 12V S000973 S000973 S000973 β βDC 24V S000935 S000935 S000935 S215002032 S212002033Other voltages available ex-indent
Instantaneous Type125 - 630A
500mS800 - 1600A
MCCB ACCESSORIES
Aux Alarm1 C/O A000744 A000744 A000744 A212001070 A212001071
1 C/O 1 C/O β β β A212001042 A212001043Rating 3A @ 240V 5A @ 250V
3A @ 500VN/O A000706 β β β βN/C A000713 β β β βRating 4A @ 240V
1A @ 500V
Maximum Configurations Accessory MCCB 125A MCCB 160A - 250A MCCB 400A - 630A MCCB 800 - 1600AGeneral purpose Auxiliary Switch 2 2 3 3 General purpose Alarm Switch 1 1 1 1 Shunt Trip or UVT 1 1 1 1 Shunt + 0 0 0 0 Auxillery 0 0 0 0 OR Accessory MCCB 125A MCCB 160A - 250A MCCB 400A - 630A Heavy Duty Auxiliary Switch 2 2 3 Heavy Duty Alarm Switch 1 1 1 Shunt Trip or UVT 1 1 1
Frame Size 125A 160 - 250A 400 - 630A 800A 1250 - 1600AE125S125
E250S250
E400S400 / S630
XS800β
XS1250XS1600
Aux1 C/O A000348 A000348 A000348 A212001005 A2120010062 C/O β β β A212001015 A2120010163 C/O β β β A212001025 A212001026Rating 3A @ 240V 5A @ 250V
3A @ 500VN/O A000300 A000300 A000300 β βN/C A000317 A000317 A000317 β βRating 4A @ 240V
1A @ 500V
4
Motor operators AC100-110V MO755606 MO755705 β β β AC 100-240V β β MO756009 β β AC 230 - 240V MO755620 MO755729 β MO212008024 MO212008025 DC 24V MO755637 MO755736 MO756016 MO212008054 MO212008055 Other voltages available ex-indent
Slide Type Mechanical Interlocks Front Rear Connection 3P (*1)
Slide Type Mechanical Interlocks Front Rear Connection 4P (*1)
Link Type Mechanical Interlocks Right Side (*2)
Link Type Mechanical Interlocks Left Side 3P (*2)
Link Type Mechanical Interlocks Left Side 4P (*2)
Cable Type Mechanical Interlocks Interlock (*2)
Cable Type Mechanical Interlocks 1m Length Interlock Cable (*2)
Cable Type Mechanical Interlocks 1.5m Length Interlock Cable (*2)
Electrical Interlocks, 500mm WireElectrical Interlocks, 1500mm Wire
Rear Mechanical Interlock Toggle Type Rear Mechanical Interlock Cable Type
M033704
M033711
M035265M035272M035289M036248
M036064
M036057
E756429E756436
M033513
M033520
M035005M035012M035029M036026
M036064
M036057
E756405E756412
400 - 630ATEC.06300H754197H754234H037207
Frame Size 800ATEC.08000H211011004ββ
160 - 250ATEC.02500H759291H728990H037016
MCCB ACCESSORIESExternal Operating HandlesDoor Mount IP54 Black Daros HandleDoor Mount IP54 Black HandleDoor Mount IP65 Black HandlePadlock Attachment Handle Locks
Daros HandlesIP54
Chain Drive Mechanism For Larger MCCBsDoor Mount
Handle IP65
125ATEC.01250H758294H758331H037016
Covers
Mechanical & Electrical Interlocks
Padlock Attachments
To fit TB2 MCCBs To fit XS MCCBs
Slide Type Link Type Electrical Type Toggle Type
M033605
M033612
M035104M035111M035128M036125
M036064
M036057
E756405E756412
M211009023
ββRear Interlockββ
M21009035
β
ββ
1250M211009025M211009036
Interpole Barrier Door FlangeTerminal Cover
See below
ββSee belowββ
β
β
ββ
1600M211009027M211009037
(*1) Order one part between two MCCBs(*2) Order one Interlock part for each MCCB
Terminal covers for Front Connection 3P 2 covers C080425 C080456 C080807 C211004018* C211004020*Terminal covers for Front Connection 4P 3 covers C080432 C080463 C080814 β βInterpole Barriers 2 Pieces per 3P MCCB C043062 C043161 C043338 C211004042* C211004042*Door Flange C044908 C044908 C045400 C211005160* C211005161*
Cable Type
1250ATEC.12500βH211011005β
1600ATEC.16000βH211011005β
Symmetrical mount
400 - 630A 800A160 - 250A125A 1250A-1600A
400 - 630A 800A160 - 250A125A 1250A-1600A
400 - 630A 800A160 - 250A125A 1250A-1600A
5
Terasaki ProfessionalSwitching Solutions
S125-NN S250-NN S400-NN S630-NN XS800-NN XS1250-NN
S125-NN4 S250-NN4 S400-NN4 S630-NN4 XS800-NN4 XS1250-NN4
3 Pole Isolator
4 Pole IsolatorEarly make, Late break Neutral
S160-NN
S160-NN4
Isolators
125A
690V3.6kA2kA
90mm120mm155mm68mm92mmS250-NJS250-NJ750A
250A
690V6kA3kA
105mm140mm165mm68mm92mmS250-NJS250-NJ1500A
400A
690V9kA5kA
140mm185mm260mm103mm145mmS400-NJS400-NJ2400A
630A
690V9kA5kA
140mm185mm260mm103mm145mmS800-NJS800-NJ3780A
800A
690V15kA9.6kA
210mm280mm273mm103mm145mmXS800-NJXS800-NJ4800A
1250A
690V32kA15kA
210mm280mm370mm120mm171mmXS1250-SEβ7500A
Ratings
Rated Current Amps
Rated Voltage Ue ACRated short circuit making capacity PeakRated short time current 0.3 secondsDimensions w - 3-Pole w - 4-Pole h d1 d2For accessories see CBBack-Up Circuit BreakerMaximum switching current AC
160A
690V6kA3kA
105mm140mm165mm68mm92mmS160-NJS160-NJ1000A
100% Rated Neutral
ISOLATORS & INTERLOCKED MCCBs
Motorised, Electrical & Mechanically interlockedβ’ 250 - 800kVAβ’ Ideal for gensetsβ’ One part number
Each set comprises:2 x 3-pole MCCBs2 x Motor operators2 x Aux interlocks1 x Mechanical interlock set
Other combinations involving circuit breakers and isolators can be assembled to your order.
XSM400
EEM400*Code EEM450* EEM500* EEM630* XSM800* XSM1250*
MOTORISED INTERLOCKED MCCBS
* Add Control Voltage for Motorised Operators: 230VAC or 24VDC eg. EEM400-230VAC
690V500A350kVA36kA0.63 - 1 x In6-12 x In
E630-NE 630AM0756009A000317M035265M035272340260280E630
690V500-800A450-500kVA65kAAdj. 63 - 1 x InAdj. 5 - 10 x In
βββββ420340300XS800
690V400A250kVA25kA0.63 - 1 x InAdj. 6-12 x In
E400-NJ 400AM0756009A00317M035265M035272340260280E400
690V400A300kVA36kA0.63 - 1 x InAdj.6-12 x In
S400-CJ 400AM0756009A000317M035265M035272340260280S400
690V630-1250A550-850kVA85kAElectronicElectronic
βββββ420530360XS1250
690V600A400kVA36kA0.63 - 1 x InElectronic
E630-NE 630AM0756009A000317M035265M035272420340300E630
Supplied in kit format Workshop Assembly
Ratings: Voltage Uc Current In Gensets Icu 400Overload Protection: Thermal Instant Description QtyMoulded Case MCCB 2Motor Operator 2Auxiliary Switch 2RHS Mechanical Interlock 1LHS Mechanical Interlock 1 Dimensions: w h dFor accessories & further specs, see CB
RCC Cert. 0808103/0805030
w d2d1
h
6
AccessoriesAuxiliary contactsAuxiliary = AuxAlarm (Trip only) = Alarm
Series XV
H21101100412TEC.8445
Frame Size 125A 400A 600-800A
A211001002A211001012βA212001067A212001039
A212001004A212001014A212001024A212001069A212001041
A212001005A212001015A212001025A212001070A212001042
Maximum Configurations MCCB MCCB Accessory 100-250A 400-1600A Shunt or UVT 1 1 Alarm 1 1 Auxiliary 2 3 Alarm + 1 1 Auxiliary 1 2Motor Operator β spring charged
(shown fitted to circuit breaker)
Rear Toggle Mechanical InterlockShown fitted to XEM800 Cable Type
Rear View
Motor operators 220-230VAC 24VDC
MO212008023MO212008053
MO212008024MO212008054
3A @ 250V; 0.4A @ 500V 5A @ 250V; 3A @ 500VUndervoltage Trips Inst: 100-120VAC 200-240VAC 500mS 100-120VAC 200-240VAC
U212002064U212002072U212002116U212002124
U211002066U211002074U211002118U211002126
U212002067U211002075U211002119U211002127
Shunt Trips 100-115VAC 200-480VAC 24VDC
S212002003S212002011S212002029
S211002005S211002013S212002031
S211002006S211002014S212002032
Covers Terminal Covers 3 Pole (set of 2)Interpole Barriers (set of 2) Door flange
C212004006C211004038C211005159
C212004016C211004042C211005160
C211004018C211004042C211005160
Mechanical Interlocks 220 - 230VAC Rear Toggle 24VDC 1m cable
M211009015β
M211009021M211009034
M211009023M211009035
Handle Mechanisms
H21101100112TEC.8145
H21201100312TEC.8345
ON control. Closing spring is electrically released and the MCCB closes.OFF control. MCCB opens and motor recharges the closing spring.RESET control. When MCCB is tripped, switching the MCCB OFF starts the motor which recharges the closing spring and resets the MCCB to the OFF position. Manual operation remains available. MCCB can be padlocked in OFF position
Other voltages available ex-indent.
Other voltages available ex-indent.
Padlock attachment Varidepth handle IP54 DAROS
XV125NJ20A (12.5-20) 4kA32A (20-32) 4kA50A (32-50) 4kA63A (40-63) 6kA100A (63-100) 6kA125A (80-125) 6kA
Current RatingIn
4/6kAAdj 0.63-1 x InFixed 13 x In
Dimensions h d1 d2 w Max depth with VDH
155mm86mm104mm90mm373mm
3-Pole XV250NJ250A (160-250)
6kAAdj 0.63-1 x InFixed 13 x In165mm103mm124mm105mm390mm
XV400NE250A (125-250)400A (200-400)
12.5kA
Electronic
260mm103mm145mm140mm385mm
XV630PE630A (315-630)
18kA
Electronic
273mm103mm145mm210mm385mm
XV800PE800A (400-800)
18kA
Electronic
273mm103mm145mm210mm385mm
1100V MCCBs
H21101100212TEC.8245
A212001003A212001013βA212001068A212001040
U212002065U212002073U212002117U212002125
S212002004S212002012S212002030
C211004008C211004038C211005159M211009017β
160-250AAux Alarm1 C/O β2 C/O β3 C/O ββ 1 C/O1 C/O 1 C/ORating
AC Breaking Capacity: Icu 1100VProtection: Thermal Magnetic (Inst.)
w d2d1
h
7
Adjustable overload protection, Ir can be set between 63% and
100% of In
Voltage presence LEDTrip indicator: The yellow button
pops up to indicate tripping due to residual current
Type A: Tripping is ensured for residual sinusoidal AC in the
presence of residual pulsating DC
Test button: Press the button to test the residual current detection
and tripping system
Adjustable time delay for residual current protection. Settings include
zero and non-trip (NT). Use NT setting with optional Residual Current
Monitor (RCM) Module
Adjustable residual current tripping thresholds. 30mA, 100mA, 300mA,
500mA, 1000mA,and 3000mA
Dielectric test device. Remove the plug to allow dielectric testing with
the CBR closed (ON).
20A (12.5-20)32A (20-32)50A (32-50)63A (40-63)100A (63-100)125A (80-125)
20A (12.5-20)32A (20-32)50A (32-50)63A (40-63)100A (63-100)125A (80-125)
250A(160-250)
ZE125-NJ
Current RatingIn
25kA8kA30mA - 3A0.63-1 x In10-12 x In
AC Breaking Capacity: Icu 400V 525VProtection: Earth Leakage Thermal Magnetic FixedDimensions see CB E125
3-Pole ZS125-NJ ZS125-GJ ZE250-NJ ZS250-NJZE125-NJ44-Pole ZS125-NJ4 ZS125-GJ4 ZE250-NJ4 ZS250-NJ4
20A (12.5-20)32A (20-32)50A (32-50)63A (40-63)100A (63-100)125A (80-125)36kA22kA30mA - 3A0.63-1 x In10-12 x InS125
65kA25kA30mA - 3A0.63-1 x In10-12 x InS125
250A (160-250)
25kA10kA30mA - 3A0.63-1 x In10-13 x InE250
36kA25kA30mA - 3A0.63-1 x In10-13 x InS250
250A(160-250)
65kA25kA30mA - 3A0.63-1 x In10-13 x InS250
ZS250-GJZS250-GJ4
240-525VAC Suitable for Single Phase installation
EARTH LEAKAGE CIRCUIT BREAKERS
For Accessories see page 4 & 5
8
Air Circuit Breakers& Accessories
MCC
B
The TemPower2 is the worldβs first βDouble Breakβ ACB, having two breaking contacts per phase. The unique pole structure means that the short time withstand rating (Icw, 1sec) is equal to the service short-circuit breaking capacity (Ics) for all models.
TemPower2 ACBs have the worldβs smallest depth resulting in space saving in switchboards.
β’ One of the smallest ACBs in the world.
β’ Double contact breaking system. Fast clearing time of 30 msec.
β’ Double insulated front body, field fit accessories.
β’ Icu = Ics = Icw. 65kA, 85kA, 100kA and 120kA versions.
β’ Characteristic curve to IEC 60 255-3. True generator protection curves in accordance with Marine Classification Rules.
β’ Monitoring of contact temperature.
β’ Reverse power protection. Zone Interlocking Unrestricted and/or restricted ground fault protection.
β’ Double opening and closing coils.
β’ All standard voltage options are available for protection relays.
TemPower2:β’ A smaller switchboard can be used.
β’ Minimizes expensive repair and disruption costs to an installation on occurrence of fault.
β’ Facilitates simple maintenance, upgrade and retro fitting.
β’ High short circuit withstand provides full selectivity up to 100kA and means no reduction of performance when tripped by an external relay.
β’ The most flexible relay on the market ensures selectivity and protection are always achieved.
β’ Provides diagnostic information and reduces factory down time.
β’ Integrated generator protection functions within the one relay.
β’ Increased reliability for critical applications.
β’ No additional cost or configuration.
9
Ics=Icw Double break contacts
Standard Specification Includes : β’ Protection Relay LSI (AGR-11BL-AL)β’ 4 AB Auxiliary Contacts β’ Padlockable Mechanical Close & Open Buttons β’ Mechanical Close & Open Indicators β’ Mechanical Indicator for Charged/Discharged State
3 Pole4 Pole on request
1250A 6300A
AIR CIRCUIT BREAKERS - FIXED & DRAWOUT
ACB Frame SizeRated Current InACB Model
* Available Ex-IndentRated Operational Voltage UeAC Rated Insulation Voltage UiIcs Service Breaking Capacity(kA, symmetrical r.m.s) 690V 440V 400/415VIcm Making Capacity (kA, asymmetrical peak) 690V 440V 400/415VIcw Short - Time Withstand(kA rms) 1 sec 3 secEndurance (Number of operating cycles)Mechanical (C/W maintenance)Mechanical (W/O maintenance)Electrical (C/W maintenance AC460V)Electrical (W/O maintenance AC460V)TimesTotal Breaking Time (sec) maxSpring Charging Time (sec) maxClosing Time (sec) max Dimensions
W 3 poleHD
Fixed TypeAR 2 AR31250 / 1600 / 2000A 2500 / 3200A*ACDC2F312HH ACDC3F325VVACD22F316HH ACDC3F332VV*ACD22F320VV β
690V 690V1000V 1000V
50 6565 8565 85
105 143143 187143 187
65 8550 65
30000 2000015000 1000012000 700010000 5000
0.03 0.0310 100.08 0.08
360mm 466mm460mm 460mm290mm 345mm
AR 4 AR64000A* 5000* / 6300A*ACDC4D340VV ACDC6D350VV*β ACDC6D363VV* β β 690V 690V1000V 1000V
85 85100 120100 120
187 187220 264220 264
100 12075 85
15000 400008000 50003000 10002500 500
0.03 0.0510 100.08 0.08
460mm 799mm460mm 460mm380mm 380mm
β’ Position Indicator β’ Drawout Handle β’ Horizontal or Vertical Connectionsβ’ Chassisβ’ Safety Shuttersβ’ Terminal Cover
Drawout Type
For other configurations contact AC/DC
AR 2 AR31250* / 1600 / 2000A 2500 / 3200A*ACDC2D312HH* ACDC3D325VVACDC2D316HH ACDC3D332VV*ACDC2D320VV β
690V 690V1000V 1000V
50 6565 8565 85
105 143143 187143 187
65 8550 65
30000 2000015000 1000012000 700010000 5000
0.03 0.0310 100.08 0.08
354mm 460mm460mm 460mm345mm 345mm
Drawout Only
w
H
D
10
Undervoltage Trips Drawout Type
116205103116105100(1*)
AC200-240V UVT Inst. Trip Control. UVT Controler - Chassis Part.UVT Coil only - D/O Body Part. Specify Controller Type.
(1*) Body Part required with UVT
Code Description
AIR CIRCUIT BREAKERS ACCESSORY SELECTION
RETROFITThe TemPower2 ACB has a compact and versatile design. It can be used to replace existing ACBs in almost any switchboard, whilst retaining original copper work and steelwork.
English Electric OB3 Switchgear for Power Station.Circa 1950. Replaced by the Terasaki AR216S 3-Pole ACB retrofit kit, complete with ASTA tested and certified copper work to BSEN 60439, 50kA for 3 seconds.
We have developed retrofit kits using TemPower2 which can replace ACBs by:GEC MitsubishiEllison SiemensMerlin Gerin WestinghouseABB Others
Undervoltage Trips Fixed Type116305103 AC200-240V UVT Inst. Trip. Fix ACB UVT Coil & Controller.
Shunt Trips Fixed and Drawout Type116106107116106114
DC220V Shunt. Continuously Rated.AC240V Shunt. Continuously Rated.
Motor for Automatic Closing116103107116103117116104107
AC220V AGR-1D motor unit. 208-220.AC220V DGR-1D motor unit. 325-440.Closing Coil AC220V. Closing Coil.
Drawout ChassisACDC2C316HHACDC2C320VVACDC3C325VV
AR216SC 3P HC/HC Chassis. Standard Specification.AR220SC 3P HC/HC Chassis. Standard Specification.AR325SC 3P VC/VC Chassis. Standard Specification.
Vertical or Horizontal Terminals116326005116326011116326015116326022116326023116226011116226015116226022116226023116218001
208-12S 3P Fixed 1/2 Set VC. Vertical Terminals.216S 3P Fixed 1/2 Set VC. Vertical Terminals.220S 3P Fixed 1/2 Set HC. Horizontal Terminals.325-32S 3P 1/2 Set HC TOP. For Fixed ACB.325-32S 3P 1/2 Set HC BTM. For Fixed ACB.216S 3P DO 1/2 Set VC. Vertical Terminals.220S 3P DO 1/2 Set HC. Horizontal Terminals.325-32S 3P DO 1/2 Set HC TOP. Horizontal Terminals.325-32S 3P DO 1/2 Set HC BTM. Horizontal Terminals.Main Shutter/H 08-20 3P 1/2Set. For Horizontal Connections.
Safety shutters fitted as standard
11
Discrimination TablesUpstream: TemPower 2 ACB with or without integral Protection Relay.Downstream: TemBreak 2 MCCB.
APPLICATION DATA
Upstream ACB
Frame 800A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A
Model
65kA
AR20
8S
AR20
8H
AR21
2S
AR21
2H
AR21
6S
AR21
6H
AR22
0S
AR22
0H
AR32
5S
AR32
5H
AR33
2S
AR33
2H
AR44
0S
AH50
C
AH60
C
80kA 65kA 80kA 65kA 80kA 65kA 80kA 100kA 85kA 100kA 100kA100kA 120kA85kABreaking Capacity125A E125NJ
S125NJS125GJH125NJL125NJ
25kA36kA65kA125kA200kA
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
TTTTT
160A/250A
S160NJS160GJN250NJS250NJS250GJS250-NES250-GES250PEH250NJL250NJ
36kA65kA25kA36kA65kA50kA65kA70kA125kA200kA
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
TTTTTTTTTT
Notes:1. All ACBs have Ii set at NON, MCR ON.2. Assuming ACB time settings are greater than MCCB.3. The above table is in accordance with IEC 60947-2, ANNEX A.
4. External relay can be used - Contact AC/DC for further details.5. All values shown at 400V AC.T = Total Selectivity
Down
stre
am M
CCB
430A/630A
E400NJS400CJS400NJS400NES400GJS400GEH400NJH400NEE630NES630CES630GE
25kA36kA50kA50kA70kA70kA125kA125kA36kA50kA70kA
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
TTTTTTTTTTT
XS800NJXH800SEXH800PJXS800SE
65kA65kA100kA50kA
800A TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
TTTT
XS1250SEXS1600SE
65kA85kA
1250A/1600A
ββ
ββ
Tβ
Tβ
TT
TT
TT
TT
TT
TT
TT
TT
TT
TT
TT
Type 2 Coordination for Motor StartersFor details of Type 2 Coordination for motor starters, please contact our Sales or Product Manager, or technical support team.
Type Tested AssembliesFor details of certified Type-Tested Assemblies using Terasaki ACBs and MCCBs, please contact our Sales or Product Manager, or technical support team.
12
Cascade TablesUpstream: TemBreak 2 MCCBDownstream: TemBreak 2 MCCB.
APPLICATION DATA
Upstream MCCB
Frame 125A 160A/250A
Model
25kA
E125
NJ
Breaking Capacity50A
S125
NJ36kA
S125
GJ
65kA
H125
NJ
125kA
L125
NJ
200kA
S160
NJ
36kA
S160
GJ
65kA
H160
NJ
125kA
L160
NJ
200kA
E250
NJ
25kA
S250
NJ
36kA
S250
GJ
65kA
S250
NE
50kA
S250
GE
65kA
S250
PE
70kA
H250
NJH2
50NE
125kA
L250
NJ
200kAS50NFE100NF
10kA10kA
2525
2525
2525
2525
2525
1515
1515
2525
2525
1515
1515
1515
1515
1515
1515
2525
2525
125A E125NJS125NJS125GJH125NJ
25kA36kA65kA125kA
ββββ
36βββ
5065ββ
6585125
β
85125150200
36βββ
5065ββ
6585125
β
85125150200
ββββ
36βββ
5065ββ
505050β
506570β
506570β
6585
125200
85125150
β
Down
stre
am M
CCB
Notes:1. All values shown at 400V AC.2. Cascade fault level limit is expressed in kA.
Notes:1. All values shown at 400V AC.2. Cascade fault level limit is expressed in kA.
Upstream MCCB
Frame 400A 630A
Model
36kA
S400
CJ
Breaking Capacity
S400
NJS4
00NE
50kA
S400
GJS4
00GE
70kA
H400
NJH4
00NE
125kA
L400
NJL4
00NE
200kA
E630
NE
36kA
S630
CE
50kA
S630
GE
70kA
TL63
0NE
125kA
XS80
0SE
50kA
XS80
0NJ
65kA
XH80
0SE
65kA
TL80
0NE
125kAXS
1250
SE85kA
XS16
00SE
100kA
Down
stre
am M
CCB
800A
S160NJS160GJH160NJE250NJS250NJS250GJS250NES250GES250PEH250NJ
36kA65kA125kA25kA36kA65kA50kA65kA70kA125kA
βββ36ββββββ
160A/250A
50ββ3650βββββ
6570β506570ββββ
85125
β6585125125125125
β
12515020085125150150150150200
βββ36ββββββ
50ββ3650βββββ
6570β506570ββββ
ββββββββββ
50ββ3650βββββ
65ββ5065βββββ
65ββ5065βββββ
65ββ5065βββββ
ββββββββββ
ββββββββββ
400A E400NJS400CJS400NJS400GJH400NJ
25kA36kA50kA75kA125kA
36ββββ
3650βββ
506570ββ
85100125150200
36ββββ
3650βββ
506570ββ
365065ββ
3650βββ
5065βββ
506565ββ
6365065
365065ββ
36506585β
657085125
β
125A E125NJS125NJS125GJH125NJ
25kA36kA65kA125kA
36βββ
3650ββ
506570β
6585125
β
85125150200
36βββ
3650ββ
506570β
ββββ
3650ββ
3650ββ
3650ββ
ββββ
ββββ
ββββ
S160NJS160GJH160NJE250NJS250NJS250GJS250NES250GES250PEH250NJ
36kA65kA125kA25kA36kA65kA50kA65kA70kA125kA
ββββββββββ
160A/250A
ββββββββββ
ββββββββββ
ββββββββββ
ββββββββββ
ββββββββββ
65βββββββββ
85125
ββββββββ
125150200
βββββββ
ββββββββββ
βββ36ββββββ
65ββ5065βββββ
5050β505050ββββ
6565β656565ββββ
6570β506570ββββ
85125
β6585
125125125125
β
12515020085
125150150150150200
13
AC/DC Dynamicsβ policy is one of continuous improvement. As such, specifications in this catalogue are subject to change without prior noticeFor terms & conditions visit our website: www.acdc.co.za
AVAILABLE VIA DISTRIBUTORS & FRANCHISES NATIONWIDE
SALES CALL CENTRE 087 806 6660 / 010 202 3400 TECHNICAL CALL CENTRE 087 806 6670 / 010 202 3500
ENQUIRIES & ORDERS ONLINE
www.acdc.co.zaHEAD OFFICE - JOHANNESBURGTel: 087 806 6650 / 010 202 [email protected] Fax: 087 807 5441 P.O. Box 19287, Primrose, 1416, South Africa26 Nguni Drive, Longmeadow Estate WestEdenvale, Gauteng, South Africa
CAPE TOWNTel: 087 806 6070 / 021 510 [email protected] Fax: 087 807 5279P.O. Box 566, Paarden Eiland, 74208 Paarden Eiland Rd, Paarden EilandCape Town, South Africa
KZNTel: 087 806 6066 / 031 700 [email protected] Fax: 087 807 5436P.O. Box 1238, Durban, 40009 Hillclimb Road, Westmead, PinetownKwazulu-Natal, South Africa
AC/D
C SF
C TE
RASA
KI
Distributed by: