tender for fire hydrant system for fire hydrant system(1).pdf · hydrant system are given the...

21
TENDER NOTICE Sealed Tender offers are invited for supply, installation & commissioning of Fire Hydrant System at our Gokul Dairy Project Complex at Gokul Shirgaon¸ Kolhapur. Only contractors having valid Licence issued by Director of Maharashtra Fire Services, Mumbai are eligible to submit Tender offer. Tender details including details of material/equipment required for fire hydrant system, scope of work and Terms & Conditions of Tender are available at our Gokul Shirgaon office from 3.2.2018 during office hours. Tender details are also availabe on our web site www.gokulmilk.coop . Sealed Tender offers duly marked as " Tender for Hydrant System" alongwith D/D towards EMD of Rs. 50,000/- should be submitted at our head office at Gokul Shirgaon, Kolhapur on or before 14.2.2018. Right to accept or reject any or all Tenders is reserved. Managing Director Chairman Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd. B-1, M.I.D.C., Gokul Shirgaon, Tal. Karveer, Dist. Kolhapur 4 16234

Upload: vancong

Post on 17-Sep-2018

239 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

TENDER NOTICE

Sealed Tender offers are invited for supply, installation & commissioning of Fire Hydrant System at our Gokul Dairy Project Complex at Gokul Shirgaon¸ Kolhapur. Only contractors having valid Licence issued by Director of Maharashtra Fire Services, Mumbai are eligible to submit Tender offer. Tender details including details of material/equipment required for fire hydrant system, scope of work and Terms & Conditions of Tender are available at our Gokul Shirgaon office from 3.2.2018 during office hours. Tender details are also availabe on our web site www.gokulmilk.coop . Sealed Tender offers duly marked as " Tender for Hydrant System" alongwith D/D towards EMD of Rs. 50,000/- should be submitted at our head office at Gokul Shirgaon, Kolhapur on or before 14.2.2018. Right to accept or reject any or all Tenders is reserved.

Managing Director ChairmanKolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd.

B-1, M.I.D.C., Gokul Shirgaon, Tal. Karveer, Dist. Kolhapur 4 16234

Page 2: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

TENDER DETAILS

Page 3: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

KOLHAPUR ZILLA SAHAKARI DUDH UTPADAK SANGH LTD., KOLHAPUR

GENERAL TERMS & CONDITIONS OF TENDER

( FIRE HYDRANT SYSTEM TENDER)

1. Tenderer must be a Licensed contractor having Licence issued by Director of Maharashtra Fire Services, Mumbai. Copy of valid Licence should be attached with the Tender.

2. This contract will be a Turn Key Job. Final NOC is to be arranged by contractor.

3. Tender offer is to be given on the Letter head of the Tenderer in the precribed format given by us .

4. Tenderers may visit the site to get idea about this work before sumitting their Tender offer.

5. Material details their specifications and quantities of required material for Fire Hydrant System are given the Tender documents. Rate offered should be inclusive of GST and transport charges.

6. Earnest Money Deposit of Rs. 50,000/- is to be given alongwith the Tender by D/D issued in the name of Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd., Kolhapur. Tender without EMD will not be considered.

7. Payment -

a) 40% amount of total contract price will be given as an advance against Bank Guarantee of equivalent amount.

b) Remaining payment will be released after satisfactory installation and succesful trials of Hydrant System within one month. This payment will be released only after getting NOC from concerned Goverment authority.

8. Sealed Tender offer duly marked as "TENDER FOR FIRE HYDRANT SYSTEM" alongwith requisite EMD should be submitted at our Head office at B-1, M.I.D.C., Gokul Shirgaon, Kolhapur on or before 14.2.2018.

9. Right to accept or reject any Tender without assigning any reason is reserved.

10.Subject to Kolhapur Jurisdiction.

Managing Director

Page 4: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH LTD., KOLHAPUR

SCOPE OF WORK -

We are inviting sealed Tender offers for supply,installation & commissioning of Fire Hydrant System for our New expanded dairy (Processing Area, Refrigeration section, milk packing section) and new boiler House. This would be a ' Turn Key Job', Supply of required equipment / material, installation and commissioning of Hydrant System in specified areas is the scope of work. Obtaining No Objection Certificate (NOC) from Fire department is in the scope of contractor. Entire details of required equipment/ material, their specifications , make and quantities are given in the prescribed Tender format.

Page 5: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

TENDER OFFER FORMAT(To be given on the Letterhead of Tenderer)

To,

The Managing Director,Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd.B-1, M.I.D.C., Gokul Shirgaon,Tal. Karveer, Dist. Kolhapur - 416 234

Sub - Tender offer for Fire Hydrant System

Dear Sir,

In continuation to your Tender Notice published in Daily Lokmat, Kolhapur on 3.2.2018, I / we submit our Tender offer for Fire Hydrant System for your Dairy Project at Gokul Shirgaon, Kolhapur . We have gone through Terms & conditions of the Tender. We are aware of the scope of work . We agree upon the Terms & Condions of the Tender.

Our Total Contract price for supply, installation and commissioning of Fire Hydrant System is Rs. ________________

(In words Rs.________________________________________________________)

This price in all inclusive contract price which is inclusive of Transport charges, installation-commissioning charges and applicable GST.

Note- Price details sheet in the format given by you is attached herewith.

Yours faithfully

Seal & Signature of Tenderer

Date -

Encl. 1) Price Details Sheet 2) Copy of Licence from Director, Fire Services, Mumbai 3) D/D towards EMD

Page 6: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

PRICE DETAILS

PART 1st - NEW BOILER HOUSE FIRE HYDRANT SYSTEM

A) FIRE HYDRANT WORK FOR NEW BOILER HOUSE.

No.

Details Of Work Qty. Supply Rate per Unit

(Including GST)

Total Amount

{I}

Installation

Rate per Unit

(Including GST)

Total Amount

{II}

1. Supply and Installing, testing, perfect alignment and proper leveling and commissioning of fire service Main Electrical Fire Pump of 2850 at 70 mtr. Head coupled type installed by auto system with all accessories. .{KIRLOSKAR MAKE}

1

2. Supply and Installing, testing, and commissioning of Diesel engine driven Pump 2850 LPM including exhaust piping, heat exchanger, residential silencer, rubber pad, starting arrangement, starting battery set, diesel oil tank mounted on suitable structural support etc. complete in all respect.{KIRLOSKAR MAKE}

1

3. Supply and Installing, testing, perfect alignment and proper leveling and commissioning of Jokey Pump of 900 LPM at 70 mtr. Head installed by auto system with all accessories. {KIRLOSKAR MAKE}

1

4. Supplying and installing, testing and commissioning of Pipeline Jindal / Zenith Birla Make. M.S.round C Class ISI Mark with welded joints to correct grade / alignment including cutting the pipes to correct length providing and welding pipes jointing by means of welding, providing and fixing with heavy MS brackets/ hangers anchor fastener . Design, testing, rectifying the leakages if any along with painting the pipes in 2 coats of enamel paints on 1 cote of red oxide primer complete as per specification with painting

Page 7: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

4. suitable type of supports, anchor fasteners, nut bolts, clamps, U bolts malleable specials such as reducers, tees, elbows, flanges including cutting, welding, fixing in/ on walls, ceiling by using suitable supports etc as per drawings. The quoted rates shall also include for chasing/ chipping walls, making bore holes in wall/ floor and making them good with filler material and finished in cement mortar etc complete.150 mm 54 mtr.

100 mm

80 mm

216 mtr.

18 mtr.

5. Butterfly Valve Supply and Installation of cast iron double flange Butterfly valve {H.SARKAR/KIRLOSKAR/ ZOLOTO/ LEADER} ISI MARK150 mm100 mm

1 1

6. Non Return Valve Supply and Installation of cast iron double flange Butterfly valve {H.SARKAR/KIRLOSKAR/ ZOLOTO/ LEADER} ISI MARK100 mm80 mm

21

7. Foot ValveSupply and Installation of cast iron foot valve –100 mm80 mm

21

8. StrainerSupplying and Installing 100 mm dia end line strainer for + ve suction as per specification No. FF-VL/ELS

1

9. Portable Fire Extinguisher {SAFEPRO/Minimax/Ceasefire/Firex BRAND}ISI6 Kg. A.B.C. Type4.5 KG CO2 Type

62

Page 8: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

10. Fire Bridge Connection Supplying and Installing Fire Service inlet with 2 way connection for supplying water in fire tank.{Radheya/Arihant Make }

1

11. Courtyard Hydrant ValveSupplying and Installing Gun Metal 63 mm Single outlet fire hydrant valve ISI, {Radheya/Arihant/Minimax/ Radiant Make}

8

12. Hose pipeSupplying Fire Fighting RRL Hose Pipe 63mm die with male/ female coupling Gun Metal (15mtr) ISI Premier Brand - A class. {Jayashree/Newage/Tulasi}

8

13. M.S.Hose BoxSupplying and Installing 16 Gauges Single Door with Glass in front with Lock & Key.

8

14. Branch PipeSupplying and Installing Gun Metal detachable hexagonal nozzle ISI

8

15. Hose ReelProviding & Fixing Fire Hose Reel, Wall Mounting Swining Type Fitted with 30 mm die. 30 mtr.long.

5

TOTAL PRICE OF 'A'i.e. TOTAL OF COLOUMN {I} & {II} RS.

Page 9: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

B) SPRINKLER SYSTEM FOR NEW BOILER HOUSE -

No.

Details Of Work Qty. Supply Rate per Unit

(Including GST)

Total Amount

{I}

Installation

Rate per Unit

(Including GST)

Total Amount

{II}

1. Supplying and installing, testing and commissioning of Pipeline Jindal / Zenith Birla Make. M.S.round C Class ISI Mark with welded joints to correct grade / alignment including cutting the pipes to correct length providing and welding pipes jointing by means of welding, providing and fixing with heavy MS brackets/ hangers anchor fastener . Design, testing, rectifying the leakages if any along with painting the pipes in 2 coats of enamel paints on 1 cote of red oxide primer complete as per specification with painting suitable type of supports, anchor fasteners, nut bolts, clamps, U bolts malleable specials such as reducers, tees, elbows, flanges including cutting, welding, fixing in/ on walls, ceiling by using suitable supports etc as per drawings. The quoted rates shall also include for chasing/ chipping walls, making bore holes in wall/ floor and making them good with filler material and finished in cement mortar etc complete.

80 mm

40 mm

30 MTR

300 MTR

2. Sprinkler Head Supply and Installing of sprinkler head pendant type .{KIRLOSKAR MAKE}

100

TOTAL PRICE OF 'B'i.e. TOTAL OF COLOUMN {I} & {II} RS.

C) FIRE ALARM SYSTEM AND SMOKE DETECTOR FOR NEW BOILER

Page 10: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

HOUSE

No.

Details Of Work Qty. Supply Rate per Unit

(Including GST)

Total Amount

{I}

Installation

Rate per Unit

(Including GST)

Total Amount

{II}

1. Fire alarm panel Supply and Installation, testing and commissioning of 2 loop networkable type Fire Alarm / detection control panel {expandable}. The panel should be able to give location of all fire / fault condition of addressable units via the address code. The panel should be able to automatically switch ON / OFF respective control module whenever any alarm is triggered .{Simence/ Tyco/ Honewell/ Bosch MAKE}

1

2. Addressable HooterSITC OF addressable type loop powered hooter complete with mounting base as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

4

3. Repeater PanelSITC OF analog addressable type active repeater fire alarm panel with backlight LCD display having controls for reset, mute, accept, silence, alarms and self test confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

1

4 Addressable Manual Call Point SITC OF analog addressable type Manual Call Point having surface or flush mounting option fully complete to EN54 having rotary decade switches for addressing complete with back box for mounting as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

5

Page 11: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

5. Addressable Smoke Detector SITC of intelligent analog addressable type photoelectric type smoke detector complete with DUAL LED hard addressable having rotary decade address switches complete with mounting base complete as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

20

6. Heat Detector SITC OF intelligent analog addressable type rate of rise / fixed heat detector complete with dual led heat addressable having rotary decade address switches complete with mounting base complete as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

4

7. CableSupply and Installation, testing and commissioning of 2 core 1.5 sq. mm armored cable shedding{red color} {Finolex/ RPG/ Nicco/ Polycab/ Siemence MAKE}

Supply and Installation, testing and commissioning of 4 core 1.5 sq. mm armored cable shedding{red color}For repeater panel {Finolex/ RPG/ Nicco/ Polycab/ Siemence MAKE}

215MTR

15MTR

TOTAL PRICE OF 'C'i.e. TOTAL OF COLOUMN {I} & {II} RS.

TOTAL OF PART 1st – (A+B+C ) RS.

Total price of New Boiler House Fire Hydrant System i.e PART 1st ( In words Rs.______________________________________________________________)

Page 12: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

PART 2nd – FIRE HYDRANT SYSTEM FOR NEW DAIRY(Fire Hydrant System for new Processing plant, Refrigeration area & packing

section) A) FIRE HYDRANT WORK FOR MILK PROCESSING PLANT.

No.

Details Of Work Qty. Supply Rate per Unit

(Including GST)

Total Amount

{I}

Installation

Rate per Unit

(Including GST)

Total Amount

{II}

1. Supply and Installing, testing, perfect alignment and proper leveling and commissioning of fire service Main Electrical Fire Pump of 2850 at 70 mtr. Head coupled type installed by auto system with all accessories. .{KIRLOSKAR MAKE}

1

2. Supply and Installing, testing, and commissioning of Diesel engine driven Pump 2850 LPM including exhaust piping, heat exchanger, residencial silencer, rubber pad, starting arrangement, starting battery set, diesel oil tank mounted on suitable structural support etc. complete in all respect.{KIRLOSKAR MAKE}

1

3. Supply and Installing, testing, perfect alignment and proper leveling and commissioning of Jokey Pump of 180 LPM at 70 mtr. Head installed by auto system with all accessories. .{KIRLOSKAR MAKE}

1

4. Supplying and installing, testing and commissioning of Pipeline Jindal / Zenith Birla Make. M.S.round C Class ISI Mark with welded joints to correct grade / alignment including cutting the pipes to correct length providing and welding pipes jointing by means of welding, providing and fixing with heavy MS brackets/ hangers anchor fastener . Design, testing, rectifying the leakages if any along with painting the pipes in 2 coats of enamel paints on 1 cote of red oxide primer complete as per specification with painting

suitable type of supports, anchor fasteners, nut bolts,

Page 13: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

clamps, U bolts malleable specials such as reducers, tees, elbows, flanges including cutting, welding, fixing in/ on walls, ceiling by using suitable supports etc as per drawings. The quoted rates shall also include for chasing/ chipping walls, making bore holes in wall/ floor and making them good with filler material and finished in cement mortar etc complete. 100 mm

80 mm

255 mtr.12 mtr.

5. Butterfly Valve Supply and Installation of cast iron double flange Butterfly valve {H.SARKAR/KIRLOSKAR/ ZOLOTO/ LEADER} ISI MARK100 mm80 mm

2 1

6. Non Return Valve Supply and Installation of cast iron double flange Butterfly valve {H.SARKAR/KIRLOSKAR/ ZOLOTO/ LEADER} ISI MARK100 mm80 mm

21

7. Foot ValveSupply and Installation of cast iron foot valve –100 mm80 mm

11

8. StrainerSupplying and Installing 100 mm dia end line strainer for + ve suction as per specification No. FF-VL/ELS

1

9. Portable Fire Extinguisher {SAFEPRO/Minimax/Ceasefire/Firex BRAND}ISI6 Kg. A.B.C. Type4.5 KG CO2 Type

20 08

10. Fire Bridge Connection Supplying and Installing Fire Service inlet with 2 way connection for supplying water in fire tank.{Radheya/Arihant Make }

1

11. Courtyard Hydrant ValveSupplying and Installing Gun

Page 14: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

Metal 63 mm Single outlet fire hydrant valve ISI, {Radheya/ Arihant/Minimax/ Radiant Make}

12

12. Hose pipeSupplying Fire Fighting RRL Hose Pipe 63mm die with male/ female coupling Gun Metal (15mtr) ISI Premier Brand - A class. {Jayashree/Newage/Tulasi}

24

13. M.S.Hose BoxSupplying and Installing 16 Gauges Double Door with Glass in front with Lock & Key.

12

14. Branch PipeSupplying and Installing Gun Metal detachable hexagonal nozzle ISI

12

15. Hose ReelProviding & Fixing Fire Hose Reel, Wall Mounting Swining Type Fitted with 30 mm die. 30 mtr.long.

4

TOTAL PRICE OF 'A'i.e. TOTAL OF COLUMN {I & II} RS.

Page 15: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

B) FIRE HYDRANT WORK FOR POUCH FILLING PLANT.

No.

Details Of Work Qty. Supply Rate per Unit

(Including GST)

Total Amoun

t

{I}

Installation

Rate per Unit

(Including GST)

Total Amount

{II}

1. Supply and Installing, testing, perfect alignment and proper leveling and commissioning of fire service Main Electrical Fire Pump of 1620 LPM at 70 mtr. Head coupled type installed by auto system with all accessories. .{KIRLOSKAR MAKE}

1

2. Supply and Installing, testing, perfect alignment and proper leveling and commissioning of Jokey Pump of 180 LPM at 70 mtr. Head installed by auto system with all accessories. .{KIRLOSKAR MAKE}

1

3. Supplying and installing, testing and commissioning of Pipeline Jindal / Zenith Birla Make. M.S.round C Class ISI Mark with welded joints to correct grade / alignment including cutting the pipes to correct length providing and welding pipes jointing by means of welding, providing and fixing with heavy MS brackets/ hangers anchor fastener . Design, testing, rectifying the leakages if any along with painting the pipes in 2 coats of enamel paints on 1 cote of red oxide primer complete as per specification with painting suitable type of supports, anchor fasteners, nut bolts, clamps, U bolts malleable specials such as reducers, tees, elbows, flanges including cutting, welding, fixing in/ on walls, ceiling by using suitable supports etc as per drawings. The quoted rates shall also include for chasing/ chipping walls, making bore holes in wall/ floor and making them good with filler material and finished in cement mortar etc complete.

Page 16: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

100 mm 96 mtr.

80mm 06 mtr.

4. Butterfly Valve Supply and Installation of cast iron double flange Butterfly valve {H.SARKAR/KIRLOSKAR/ ZOLOTO/ LEADER} ISI MARK100 mm

1

6. Non Return Valve Supply and Installation of cast iron double flange Butterfly valve {H.SARKAR/KIRLOSKAR/ ZOLOTO/ LEADER} ISI MARK100 mm80 mm

11

7. Foot ValveSupply and Installation of cast iron foot valve –100 mm80 mm

11

8. StrainerSupplying and Installing 100 mm dia end line strainer for + ve suction as per specification No. FF-VL/ELS

1

9. Portable Fire Extinguisher {SAFEPRO/Minimax/Ceasefire/Firex BRAND}ISI

6 Kg. A.B.C. Type4.5 KG CO2 Type

8 2

10. Fire Bridge Connection Supplying and Installing Fire Service inlet with 2 way connection for supplying water in fire tank.{Radheya/Arihant Make }

1

11. Courtyard Hydrant ValveSupplying and Installing Gun Metal 63 mm Single outlet fire hydrant valve ISI, {Radheya/Arihant/Minimax/ Radiant Make}

4

12. Hose pipeSupplying Fire Fighting RRL Hose Pipe 63mm die with male/ female coupling Gun Metal (15mtr) ISI Premier Brand - A class. {Jayashree/Newage/Tulasi}

4

Page 17: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

13. M.S.Hose BoxSupplying and Installing 16 Gauges Sngle Door with Glass in front with Lock & Key.

4

14. Branch PipeSupplying and Installing Gun Metal detachable hexagonal nozzle ISI

4

15. Hose ReelProviding & Fixing Fire Hose Reel, Wall Mounting Swining Type Fitted with 30 mm die. 30 mtr.long.

4

TOTAL PRICE OF 'B'i.e. TOTAL OF COLUMN {I & II} RS.

Page 18: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

C) FIRE ALARM SYSTEM AND SMOKE DETECTOR FOR MILK PROCESSING PLANT

No.

Details Of Work Qty. Supply Rate per Unit

(Including GST)

Total Amount

{I}

Installation

Rate per Unit

(Including GST)

Total Amount

{II}

1. Fire alarm panel Supply and Installation, testing and commissioning of 2 loop networkable type Fire Alarm / detection control panel {expandable}. The panel should be able to give location of all fire / fault condition of addressable units via the address code. The panel should be able to automatically switch ON / OFF respective control module whenever any alarm is triggered .{Simence/ Tyco/ Honewell/ Bosch MAKE}

1

2. Addressable HooterSITC OF addressable type loop powered hooter complete with mounting base as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

12

3. Repeater PanelSITC OF analog addressable type active repeater fire alarm panel with backlight LCD display having controls for reset, mute, accept, silence, alarms and self test confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

1

4. Addressable Manual Call Point SITC OF analog addressable type Manual Call Point having surface or flush mounting option fully complete to EN54 having rotary decade switches for addressing complete with back box for mounting as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

12

Page 19: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

5. Addressable Smoke Detector SITC of intelligent analog addressable type photoelectric type smoke detector complete with DUAL LED hard addressable having rotary decade address switches complete with mounting base complete as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

40

6. Heat Detector SITC OF intelligent analog addressable type rate of rise / fixed heat detector complete with dual led heat addressable having rotary decade address switches complete with mounting base complete as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

6

7. CableSupply and Installation, testing and commissioning of 2 core 1.5 sq. mm armored cable shedding{red color} {Finolex/ RPG/ Nicco/ Polycab/ Siemence MAKE}

350MTR

Supply and Installation, testing and commissioning of 4 core 1.5 sq. mm armored cable shedding{red color}For repeater panel {Finolex/ RPG/ Nicco/ Polycab/ Siemence MAKE}

55MTR

TOTAL PRICE OF 'C'i.e. TOTAL OF COLUMN {I & II} RS.

Page 20: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

D) FIRE ALARM SYSTEM AND SMOKE DETECTOR FOR POUCH FILLING PLANT.

No.

Details Of Work Qty. Supply Rate per Unit

(Including GST)

Total Amoun

t

{I}

Installation

Rate per Unit

(Including GST)

Total Amount

{II}

1. Fire alarm panel Supply and Installation, testing and commissioning of 2 loop networkable type Fire Alarm / detection control panel {expandable}. The panel should be able to give location of all fire / fault condition of addressable units via the address code. The panel should be able to automatically switch ON / OFF respective control module whenever any alarm is triggered.{Simence/Tyco/ Honewell/ Bosch MAKE}

1

2. Addressable HooterSITC OF addressable type loop powered hooter complete with mounting base as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

2

3. Repeater PanelSITC OF analog addressable type active repeater fire alarm panel with backlight LCD display having controls for reset, mute, accept, silence, alarms and self test confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

1

4. Addressable Manual Call Point SITC OF analog addressable type Manual Call Point having surface or flush mounting option fully complete to EN54 having rotary decade switches for addressing complete with back box for mounting as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

6

Page 21: Tender for Fire Hydrant System for Fire Hydrant System(1).pdf · Hydrant System are given the Tender documents. Rate offered should be ... KOLHAPUR JILHA SAHAKARI DUDH UTPADAK SANGH

5. Addressable Smoke Detector SITC of intelligent analog addressable type photoelectric type smoke detector complete with DUAL LED hard addressable having rotary decade address switches complete with mounting base complete as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

20

6. Heat Detector SITC OF intelligent analog addressable type rate of rise / fixed heat detector complete with dual led heat addressable having rotary decade address switches complete with mounting base complete as required confirming to BS 5839 standards and duly approved by EN54/ LPCB/ VDS/ UL/ BSA . {Simence/ Tyco/ Honewell/ Bosch MAKE}

3

7. CableSupply and Installation, testing and commissioning of 2 core 1.5 sq. mm armored cable shedding{red color} {Finolex/ RPG/ Nicco/ Polycab/ Siemence MAKE}

100MTR

Supply and Installation, testing and commissioning of 4 core 1.5 sq. mm armored cable shedding{red color}For repeater panel {Finolex/ RPG/ Nicco/ Polycab/ Siemence MAKE}

75MTR

TOTAL PRICE OF 'D'i.e. TOTAL OF COLUMN {I & II} RS.

TOTAL OF PART 2nd (A+B+C+ D ) Rs.

Total price of Fire Hydrant System for New Dairy i.e. PART 2nd ( In words Rs._________________________________________________)

TOTAL CONTRACT PRICE (i.e, Part 1st + Part 2nd ) = Rs. ______________

(Total Contract price In words Rs.__________________________________________)

Signature of Tenderer