Page 1: TENDER DOCUMENT - Engineering Projects · TENDER DOCUMENT TENDER No.: EPI ... Item rates shall be furnished as per BOQ items & shall be part of Price ... SITC of Solar System and

TENDER DOCUMENT

TENDER No.: EPI/ERSite/685/SSWTS/065

FOR

Tender For “Supply, Installation, Testing & Commissioning of Solar System and other related works” for Construction of Bihar Police Academy Project, Rajgir, Nalanda, Bihar.

VOLUME – III

(Price Bid and Bill of Quantity)

ENGINEERING PROJECTS (INDIA) LIMITED

(A GOVT. OF INDIA ENTERPRISE) Core-3, SCOPE Complex,

7, Lodhi Road, New Delhi – 110003

Page 2: TENDER DOCUMENT - Engineering Projects · TENDER DOCUMENT TENDER No.: EPI ... Item rates shall be furnished as per BOQ items & shall be part of Price ... SITC of Solar System and

1.0 2 x 50 kWp (Different

locations) Grid Connected

Solar Power Plant.

2.0 2 x 35 kWp (Different

locations) Grid Connected

Solar Power Plant.

3 2 x 35 kWp (At Different

locations) Battery Back-up

Solar Power Plant.

Total

Note:Item rates shall be furnished as per BOQ items & shall be part of Price Schedule.All Price shall be inclusive of all

Taxes & Duties including Service Tax as per clause no 10 of ACC

Engineering Projects (I) Limited

Bihar Police Academy Project

Rajgir ,Nalanda

Name of Work : SITC of Solar System and Wind Turbine System

Price Schedule

SI. No. DESCRIPTIONTO BE QUOTED BY TENDERER

Total Amount( Rs.)

In figures In words

TOTAL TENDER VALUE ( IN WORDS) : Rupees

Page 3: TENDER DOCUMENT - Engineering Projects · TENDER DOCUMENT TENDER No.: EPI ... Item rates shall be furnished as per BOQ items & shall be part of Price ... SITC of Solar System and

C.P.KUKREJA ASSOCIATES

Sl.

No.

Description Unit Qty. Rate Amount

Solar System

1 Supply, Installation, Testing and Commissioning at site including associated civil works where-ever

applicable for generating solar PV of 100 kWp (2 x 50 kWp) with the following items complete as

required:

2 x 50 kWp (Different locations) Grid Connected Solar Power Plant.

1.1 Solar PV Modules with frame of 24V/220 Wp (minimum), polycristaline type. Nos. 450

1.2 Solar PV Modules mounting structure as required. set 2

1.3 Array Junction Box Nos. 18

1.4 Main Junction Box No. 2

1.5 Grid Interactive Inverter 50kW / 50KVA 415V No. 2

1.6 DC Distribution Board No. 2

1.7 AC Distribution Board No. 2

1.8 Cabling from Battery Bank to Solar PV Cells

a) 1C x 4 sq.mm PVC Cu cable mtr 2000

b) 2C x 16 sq.mm PVC Cu cable mtr 350

c) 1C x 50 sq.mm PVC Cu cable mtr 150

d) 4 C x 35 sq.mm PVC Cu cable mtr 50

Engineering Projects (I) Limited

Bihar Police Academy ProjectRajgir ,Nalanda

Name of Work : SITC of Solar System

Bill of Quantity cum Un-Price Bid

A-BPA-SSWTS-ESTIMATE FILE NO.-(33) Page-1

Page 4: TENDER DOCUMENT - Engineering Projects · TENDER DOCUMENT TENDER No.: EPI ... Item rates shall be furnished as per BOQ items & shall be part of Price ... SITC of Solar System and

C.P.KUKREJA ASSOCIATES

Sl.

No.

Description Unit Qty. Rate Amount

1.9 Installation Kit set 2

1.10 Earthing Kit set 2

1.11 Lightning and Overvoltage protection set 2

1.12 Spares for 5 years warranty set 2

Sub-Total of 1 (in Rs.)

2 Supply, Installation, Testing and Commissioning at site including associated civil works where-ever

applicable for generating solar PV of 70 kWp (2 x 35 kWp) with the following items complete as

required:

2 x 35 kWp (Different locations) Grid Connected Solar Power Plant.

2.1 Solar PV Modules with frame of 24V/220 Wp (minimum), polycristaline type with min 16%

efficiency. Nos. 320

2.2 Solar PV Modules mounting structure as required. set 2

2.3 Array Junction Box Nos. 18

2.4 Main Junction Box No. 2

2.5 Grid Interactive Inverter 35kW / 35KVA, 415V No. 2

2.6 DC Distribution Board No. 2

2.7 AC Distribution Board No. 2

2.8 Cabling from Battery Bank to Solar PV Cells

a) 1C x 4 sq.mm PVC Cu cable mtr 500

b) 2C x 10 sq.mm PVC Cu cable mtr 300

c) 1C x 35 sq.mm PVC Cu cable mtr 340

d) 4 C x 16 sq.mm PVC Cu cable mtr 100

2.9 Installation Kit set 2

2.10 Earthing Kit set 2

A-BPA-SSWTS-ESTIMATE FILE NO.-(33) Page-2

Page 5: TENDER DOCUMENT - Engineering Projects · TENDER DOCUMENT TENDER No.: EPI ... Item rates shall be furnished as per BOQ items & shall be part of Price ... SITC of Solar System and

C.P.KUKREJA ASSOCIATES

Sl.

No.

Description Unit Qty. Rate Amount

2.11 Lightning and Overvoltage protection set 2

2.12 Spares for 5 years warranty set 2

Sub-Total of 2 (in Rs.)

3 Supply, Installation, Testing and Commissioning at site including associated civil works where-ever

applicable for generating solar PV of 70 kWp (2 x 35 kWp) with the following items complete as

required:

2 x 35 kWp (At Different locations) Battery Back-up Solar Power Plant.

3.1 Solar PV Modules with frame of 24V/220 Wp (minimum), polycristaline type with min 16%

efficiency. Nos. 320

3.2 Solar PV Modules mounting structure as required. set 2

3.3 Array Junction Box Nos. 4

3.4 Main Junction Box No. 2

3.5 Grid Interactive Inverter 35kW / 35KVA, 415V No. 2

3.6 Battery Bank 240V, 600AH Lead Acid @C10, 27 deg C with accessories set 2

3.7 DC Distribution Board No. 2

3.8 AC Distribution Board No. 2

3.9 Cabling from Battery Bank to Solar PV Cells

a) 1C x 4 sq.mm PVC Cu cable mtr 200

b) 2C x 10 sq.mm PVC Cu cable mtr 300

c) 1C x 35 sq.mm PVC Cu cable mtr 220

d) 4C x 16 sq.mm PVC Cu cable mtr 70

3.10 Installation Kit set 2

A-BPA-SSWTS-ESTIMATE FILE NO.-(33) Page-3

Page 6: TENDER DOCUMENT - Engineering Projects · TENDER DOCUMENT TENDER No.: EPI ... Item rates shall be furnished as per BOQ items & shall be part of Price ... SITC of Solar System and

C.P.KUKREJA ASSOCIATES

Sl.

No.

Description Unit Qty. Rate Amount

3.11 Earthing Kit set 2

3.12 Lightning and Overvoltage protection set 2

3.13 Spares for 5 years warranty set 2

Sub-Total of 3 (in Rs.)

Total (in Rs.)

Total (in word Rs.):

A-BPA-SSWTS-ESTIMATE FILE NO.-(33) Page-4