tempsmart technique guide (chair side)€¦ · pea-sized amount. place tempsmart into the...

2
TEMPSMART Technique Guide (Chair side) Direct method (chair side) 3 4 5 Take impression before preparation of abutment tooth. Preparation of abutment tooth Block out and apply separating medium Bleed cartridge a pea-sized amount. Place TEMPSMART into the impression. Place impression within 45 sec of start of dispensing material Remove impression between 2 and 2.5 mins after dispensing material. Remove cured material if residue remains. 6 8 7 9 10 Trim excess material Remove temporary from impression, light cure on occlusal surface for 5 sec. per tooth 1 (Self cure : wait 5 min after dispensing material). Finish and polish surface. Control bite to minimize occlusal stress and load. Seat temporary Material for margin adaptation and repairing Margin adaptation: TEMPSMART (Light curing is necessary), self curing acrylic resin, composite resin Repair: TEMPSMART (Light curing is necessary), self curing acrylic resin, flowable / injectable composite resin Expose new surface to prevent low bond strength due to saliva contamination. CERAMIC PRIMER II enhances bond strength. 1 Do not perform final cure on tooth in order to minimize heat transfer. 2 6 1 45 sec 2 min 2:30 Start dispensing

Upload: others

Post on 16-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TEMPSMART Technique Guide (Chair side)€¦ · pea-sized amount. Place TEMPSMART into the impression. Place impression within 45 sec of dispensing material, and remove it 3 min after

左右246×天地138mm

TEMPSMART Technique Guide (Chair side)

TEMPSMART Technique Guide (Laboratory)

Direct method (chair side)

3 4 5Take impression before preparation of abutment tooth.

Preparation of abutment tooth

Block out and apply separating medium

Bleed cartridge a pea-sized amount. Place TEMPSMART into the impression.

Place impression within 45 sec of start of dispensing material

Remove impression between 2 and 2.5 mins after dispensing material.Remove cured material if residue remains.

687 9 10

Trim excess material Remove temporary from impression, light cure on occlusal surface for 5 sec. per tooth1 (Self cure : wait 5 min after dispensing material).

Finish and polish surface. Control bite to minimize occlusal stress and load.

Seat temporary

Indirect method (Laboratory)

Take impression after wax up.

Remove wax Block out and apply separating medium

Bleed cartridge a pea-sized amount. Place TEMPSMART into the impression.

Place impression within 45 sec of dispensing material, and remove it 3 min after start of dispensing.

Light cure for 1 min with lab curing unit, keeping the temporary on the model.(Self cure: wait 5 min from start of dispensing.

Finish and polish. Control bite to minimize occlusal stress and load.

Complete restoration

13009476301051TZ

Material for margin adaptation and repairingMargin adaptation: TEMPSMART (Light curing is necessary), self curing acrylic resin, composite resinRepair: TEMPSMART (Light curing is necessary), self curing acrylic resin, flowable / injectable composite resinExpose new surface to prevent low bond strength due to saliva contamination. CERAMIC PRIMER II enhances bond strength.1Do not perform final cure on tooth in order to minimize heat transfer.

1 2 3 4 5 6

8 97

Before removing excess material, remove the cured temporary. This helps retrieval from model.

2 61

Recommended for optimal performance, store in a cool and dark place(4 - 25°C / 39.2 - 77.0°F) away from high temperatures or direct sunlight.

GC CORPORATIONTOKYO, JAPAN

ConsultInstructionsfor Use

45 sec 2 min 2:30Start dispensing

45 sec 3 minStart dispensing

25℃

4℃

Page 2: TEMPSMART Technique Guide (Chair side)€¦ · pea-sized amount. Place TEMPSMART into the impression. Place impression within 45 sec of dispensing material, and remove it 3 min after

左右246×天地138mm

TEMPSMART Technique Guide (Chair side)

TEMPSMART Technique Guide (Laboratory)

Direct method (chair side)

3 4 5Take impression before preparation of abutment tooth.

Preparation of abutment tooth

Block out and apply separating medium

Bleed cartridge a pea-sized amount. Place TEMPSMART into the impression.

Place impression within 45 sec of start of dispensing material

Remove impression between 2 and 2.5 mins after dispensing material.Remove cured material if residue remains.

687 9 10

Trim excess material Remove temporary from impression, light cure on occlusal surface for 5 sec. per tooth1 (Self cure : wait 5 min after dispensing material).

Finish and polish surface. Control bite to minimize occlusal stress and load.

Seat temporary

Indirect method (Laboratory)

Take impression after wax up.

Remove wax Block out and apply separating medium

Bleed cartridge a pea-sized amount. Place TEMPSMART into the impression.

Place impression within 45 sec of dispensing material, and remove it 3 min after start of dispensing.

Light cure for 1 min with lab curing unit, keeping the temporary on the model.(Self cure: wait 5 min from start of dispensing.

Finish and polish. Control bite to minimize occlusal stress and load.

Complete restoration

13009476301051TZ

Material for margin adaptation and repairingMargin adaptation: TEMPSMART (Light curing is necessary), self curing acrylic resin, composite resinRepair: TEMPSMART (Light curing is necessary), self curing acrylic resin, flowable / injectable composite resinExpose new surface to prevent low bond strength due to saliva contamination. CERAMIC PRIMER II enhances bond strength.1Do not perform final cure on tooth in order to minimize heat transfer.

1 2 3 4 5 6

8 97

Before removing excess material, remove the cured temporary. This helps retrieval from model.

2 61

Recommended for optimal performance, store in a cool and dark place(4 - 25°C / 39.2 - 77.0°F) away from high temperatures or direct sunlight.

GC CORPORATIONTOKYO, JAPAN

ConsultInstructionsfor Use

45 sec 2 min 2:30Start dispensing

45 sec 3 minStart dispensing

25℃

4℃