temperature sensors for molten … met tec* expendable thermocouples that fullfil the greatest...

4
ECIL MET TEC* expendable thermocouples that fullfil the greatest variety of needs of temperature measurements in industries that process molten metals, such as Foundries and Steel Mills. Manufactured according to rigid quality requirements, these sensors are rugged enough to withstand the immersion in molten metal as well to measure the temperature with the required accuracy. These thermocouples are able to measure the temperature of metals and alloys within the range from 2000 ºF up to 3270 ºF, in BOFs (Basic Oxygen Furnaces), Blast Furnaces, Electrical Arc or Induction Furnaces, Melting Furnaces, ladles, continuous casting distributors, or any other measuring point that allows the thermocouples immersion. To properly select which product of this thermocouples family is the most suitable, the followings aspects have to be taken into consideration: operators safety, immersion requirements (furnace or ladle capacity and access) and molten metal conditions (temperature, slag etc). The thermocouples can be of Type-S (Pt-10%Rh/Pt), Type-R (Pt-13%Rh/Pt) or Type-B (Pt-6%Rh/Pt-30%Rh) and are calibrated according to the International Temperature Standards. They are also available in small diameter (3/8”) and large diameter (3/4”) versions, with ceramic body. The large diameter version is more sturdy than the small diameter one, being used in heavy-duty applications. Where operator and/or equipment safety can be affected by metal splashes, it's recommended to use the NS (non-splash) thermocouples. The non-splash protection which partial or totally covers the cardboard tube, avoids splashes during the sensor immersion. The high level of reliability and accuracy supported by an effective permanent technical service make the ECIL MET TEC* thermocouples the perfect solution to meet the rigorous quality customers demand. TEMPERATURE SENSORS FOR MOLTEN METALS TERMOTIP* CAT000103 - Page 1 / 4 - REV 01 - 07/01/15

Upload: letram

Post on 20-May-2018

221 views

Category:

Documents


2 download

TRANSCRIPT

ECIL MET TEC* expendable thermocouples that fullfil the greatest variety of needs of temperature measurements in industries that process molten metals, such as Foundries and Steel Mills. Manufactured according to rigid quality requirements, these sensors are rugged enough to withstand the immersion in molten metal as well to measure the temperature with the required accuracy.

These thermocouples are able to measure the temperature of metals and alloys within the range from 2000 ºF up to 3270 ºF, in BOFs (Basic Oxygen Furnaces), Blast Furnaces, Electrical Arc or Induction Furnaces, Melting Furnaces, ladles, continuous casting distributors, or any other measuring point that allows the thermocouples immersion.

To properly select which product of this thermocouples family is the most suitable, the followings aspects have to be taken into consideration: operators safety, immersion requirements (furnace or ladle capacity and access) and molten metal conditions (temperature, slag etc).

The thermocouples can be of Type-S (Pt-10%Rh/Pt), Type-R (Pt-13%Rh/Pt) or Type-B (Pt-6%Rh/Pt-30%Rh) and are calibrated according to the International

Temperature Standards.

They are also available in small diameter (3/8”) and large diameter (3/4”) versions, with ceramic body. The large diameter version is more sturdy than the small diameter one, being used in heavy-duty applications.

Where operator and/or equipment safety can be affected by metal splashes, it's recommended to use the NS (non-splash) thermocouples. The non-splash protection which partial or totally covers the cardboard tube, avoids splashes during the sensor immersion.

The high level of reliability and accuracy supported by an effective permanent technical service make the ECIL MET TEC* thermocouples the perfect solution to meet the rigorous quality customers demand.

TEMPERATURE SENSORS FOR MOLTEN METALS

TERMOTIP*

CAT000103 - Page 1 / 4 - REV 01 - 07/01/15

Ordering Information

The TERMOTIP* thermocouples are produced in the Unilock version 3/8” (small diameter), for general purpose and MKV version (3/4” large diameter), for heavy-duty applications.

Applications:

- FOUNDRY: induction, channel and EAF melting furnaces, ladle, holding furnace and auto-pour tundish.- STEEL MILL: BOF, EAF, Ladle, Tundish, Blast Furnace and Secondary Metallurgy Stations.

E.g.: (US only)TL1048ST: TERMOTIP* sensor, large diameter (3/4”), type S, 48" long, steel cap, ceramic housing, IPTS48 and regular I.D.

Remark: Type R and B thermocouples are always supplied with wires calibrated according to the IPTS 68.

CAT000103 - Page 2 / 4 - REV 01 - 07/01/15

T - _______ - _______ - _______ - _______ - _______ - ______ - ________________

Internal Diameter Blank = Regular id TB18 = Smaller id

Type S T/C Calibration Blank = IPTS68 48 = IPTS48 Housing Blank = ceramic P = Plastic S = Steel Protection Cap Size ST = Steel (US inches) AL = Aluminum 300 = 300mm CU = Copper 600 = 600mm 900 = 900mm 1200 = 1200mm 1600 = 1600mm 12 = 12" 24 = 24" 36 = 36" 48 = 48" 60 = 60" Thermocouple Type 10 = Type 13 = Type R 630 = Type B Version S = Small diameter (3/8”) L = Large diameter (3/4”)

US Market Blank = IPTS48 68 = IPTS68

Other countries Blank = IPTS68 48 = IPTS48

Type S T/C Calibration

Thermocouple Type10 = Type S13 = Type R630 = Type B

Version S = Small diameter (3/8”)L = Large diameter (3/4”)

Ordering Information

TNS NON-SPLASH THERMOCOUPLES

Produced in the 3/8” (small diameter) version, it has a non-splash protection, which avoids splashes during the sensor immersion in the molten metal bath.

Applications:

- FOUNDRY: induction, channel and EAF melting furnaces, ladle, holding furnace, auto-pour tundish.- STEEL MILL: EAF, Ladle, Tundish, Blast Furnace and Secundary Metallurgy Stations.

E.g.: (US only)TNS102436AL: Thermocouple non-splash, type S, 24" NS sleeve, 36" long, Aluminum cap, ceramic housing, IPTS68 and regular I.D.

TNS -__ - _____ - _______ - _____ - ______________ - ___________ - ________________ - ______ - _______________

Internal Diameter Blank = Regular id TB18 =Smaller id

Type S T/C Calibration Blank = IPTS68 48 =IPTS48 Housing Blank = Ceramic P = Plastic S =Steel Protection Cap ST = Steel AL = Aluminum CU = Copper LQ = Longer quartz STA = Steel + Additional cap (plastic) ALA = Aluminum + Additional cap (plastic) Extended outer tube Blank = no outer tube OT = with outer tube

Non Splash Length 300 = 300mm 600 = 600mm 900 = 900mm Size Length 300 = 300mm 600 = 600mm 900 = 900mm 1200 = 1200mm 1500 = 1500mm Thermocouple Type 10 = Type S 13 = Type R 630 = Type B

Non Splash Type Blank = Shell FC = Ceramic Fiber NN = Shell with naked neck FN = Ceramic Fiber with naked neck

Remark: Type R and B thermocouples are always supplied with wires calibrated according to the IPTS 68.

CAT000103 - Page 3 / 4 - REV 01 - 07/01/15

US Market Blank = IPTS48 68 = IPTS68

Other countries Blank = IPTS68 48 = IPTS48

Type S T/C Calibration

Non Splash Length (US = inches) 300 = 300mm 600 = 600mm 900 = 900mm 12 = 12" 24 = 24" 36 = 36"

Size Length (US = inches) 300 = 300mm 600 = 600mm 900 = 900mm 1200 =1200mm 12 = 12" 24 = 24" 36 = 36" 48 = 48"

Non Splash Type Blank = Shell FC = Ceramic Fiber NN = Shell with naked neck FN = Ceramic Fiber with naked neck

Thermocouple Type 10 = Type S 13 = Type R 630 = Type B

Small Diameter (3/8”)

TNS

Functional Dimensions

Large Diameter (3/4”)

TNS Long quartz

CAT000103 - Page 4 / 4 - REV 01 - 07/01/15

Ecil Met Tec Ltda has the right to change information from this catalogue without previous notice.

Ecil Met Tec LtdaRua Benjamin da Silveira Baldy, 2001Paulas e Mendes - Piedade/SPTel.: (15) 3244.8075 / 3244.8006Cep 18170-000www.ecilmettec.com.br

Copyright ECIL MET TEC Ltda. - 2015/07©

TERMOTIP and ECIL MET TEC are trademarks or registered trademarks of the VESUVIUS group of companies.