temperature measurement by mitesh kumar
TRANSCRIPT
![Page 1: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/1.jpg)
Temperature Measurement
Mitesh kumarRall no-10300513026
Applied Electronics & Instrumentation Engg.Haldia Institute of Technology
![Page 2: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/2.jpg)
Bimetallic Strip
![Page 3: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/3.jpg)
Bimetallic Dial Thermometer
![Page 4: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/4.jpg)
Bimetallic Dial Thermometer working
![Page 5: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/5.jpg)
Helical type
![Page 6: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/6.jpg)
Video on bimetallic property
9. Thermodynamics - Example - Thermal Expansion Bimetal strip.mp4
![Page 7: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/7.jpg)
Filled in system
• Class I – liquid filled• Class II – vapor filled• Class III – gas filled• Class IV/V – mercury filled
![Page 8: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/8.jpg)
Class I – liquid filled
![Page 9: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/9.jpg)
Class II – vapor filled
II A II B
![Page 10: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/10.jpg)
Class II – vapor filled
II C II D
![Page 11: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/11.jpg)
Class III – gas filledClass IV/V – mercury filled
Class V
![Page 12: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/12.jpg)
Thermopile
![Page 13: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/13.jpg)
Thermocouple Sheath
• Thermocouple junctions are prone to contamination by gases,liquids,and other metals.
• The metals contamination alters the thermoelectric behavior of the device such that its characteristic varies from that published in standard table.
![Page 14: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/14.jpg)
Table for sheath metalsmaterial Max operating temp(c)
Mild steel 900 ⁰C
Fused silica 1000 ⁰C
Recrystallised alumina 1850 ⁰C
Magnesia 2400 ⁰C
Thoria 2600 ⁰C
![Page 15: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/15.jpg)
Ice bath tech
![Page 16: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/16.jpg)
Iso-thermal block
• Insert short cu wire b/w both voltmeter terminals and thermocouple leads and place these new junction on an iso-thermal block
• This change eliminates the junctions J3 & J4 because cu is joined to cu at these points
• Place ref. junction not in ice bath but in isothermal block.• From the law of intermediate metals we know that when
junctions in series are at same temperature their makes no change
• Finally J4 and Jref can be replaced by one junction.
![Page 17: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/17.jpg)
Iso-thermal block
![Page 18: Temperature measurement By Mitesh Kumar](https://reader036.vdocuments.mx/reader036/viewer/2022062412/5872ff331a28ab8c718b7e8f/html5/thumbnails/18.jpg)
Suction Pyrometers