technology solutions introducing the first iecex … construct table let stahl rack mount them for...

2
Catalog Construct Table Let STAHL rack mount them for you Classifications IECEx • Ex nA IIC T3 Gc • IP66 • 316 Stainless Steel • Non-ventilated • Indoor/Outdoor • Floor/Wall Mounting Contact Us Online by clicking the online chat button at rstahl.com Transforming Certifications Into Savings Example: 7820/1-150-060-070-2-2 7820/ a - cccc - ddd - eee - t - g Phase (a) 1= Single Phase 2= Three Phase Rating (ccc) 150 = 15.0 kVA 300 = 30.0 kVA 450 = 45.0 kVA 750 = 75.0 kVA (3 phase only) 159 = 150.0 kVA (3 phase only) OOR = Other On Request (please specify) Primary Voltage (ddd) 060 = 380V 070 = 415V 071 = 400V 109 = 690V OOR = Other On Request (please specify) Secondary Voltage (eee) 071 = 400V (Y-Y) 070 = 415V (Y-Y) 140 = 415Y/240 (Y-Y) 141 = 400Y / 231V (Y-D) 180 = 380Y / 220V (Y-D) 090 = 415 / 230V OOR = Other On Request (please specify) Taps (t) 0 = No taps 2 = +/- 2.5% Wiring Entry (g) 1 = Connection Box with terminals 2 = Direct Connection Conduit 3 = Bottom Gland Plate Introducing The First IECEx Certified Transformer In The Industry! Solve your IECEx cabeling issues using the ExTran® IECEx certified transformer system from R. STAHL. Ideal for all applications requiring IECEx Zone 2 explosion protected certifications. Special savings include lighting applications previously challenged with the need to convert typical 3 phase, 3 wire electrical systems to 4 wire. With the ExTran® IECEx Zone 2 transformer, one can run the traditional 3 wire system all the way to the hazardous area, and convert to a 4 wire system. This saves significant cabeling costs. Technology Solutions

Upload: lynhan

Post on 12-May-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

Catalog Construct Table Let STAHL rack mount them for you

ClassificationsIECEx

• Ex nA IIC T3 Gc

• IP66

• 316 Stainless Steel

• Non-ventilated

• Indoor/Outdoor

• Floor/Wall Mounting

Contact Us Online by

clicking the online

chat button at

rstahl.com

Transforming Certifications Into Savings

Example: 7820/1-150-060-070-2-2

7820/ a - cccc - ddd - eee - t - g

Phase (a)1= Single Phase2= Three Phase

Rating (ccc)150 = 15.0 kVA300 = 30.0 kVA450 = 45.0 kVA750 = 75.0 kVA (3 phase only) 159 = 150.0 kVA (3 phase only) OOR = Other On Request (please specify)

Primary Voltage (ddd)060 = 380V070 = 415V071 = 400V 109 = 690VOOR = Other On Request (please specify)

Secondary Voltage (eee) 071 = 400V (Y-Y)070 = 415V (Y-Y)140 = 415Y/240 (Y-Y)141 = 400Y / 231V (Y-D)180 = 380Y / 220V (Y-D)090 = 415 / 230VOOR = Other On Request (please specify)

Taps (t)0 = No taps2 = +/- 2.5%

Wiring Entry (g) 1 = Connection Box with terminals2 = Direct Connection Conduit3 = Bottom Gland Plate

Introducing The First IECEx Certified Transformer In The Industry!Solve your IECEx cabeling issues using the ExTran® IECEx certified transformer system from R. STAHL. Ideal for all applications requiring IECEx Zone 2 explosion protected certifications. Special savings include lighting applications previously challenged with the need to convert typical 3 phase, 3 wire electrical systems to 4 wire. With the ExTran® IECEx Zone 2 transformer, one can run the traditional 3 wire system all the way to the hazardous area, and convert to a 4 wire system. This saves significant cabeling costs.

Technology Solutions

R.STAHL, Inc.13259 N. Promenade Blvd.Stafford, TX 77477 800.782.4357713.792.9300Fax: 713.797.0105

R. STAHL, LTD.7003-56th Ave.Edmonton, Alberta,Canada T6B 3L2780.490.4912 Fax: 780.469.5525

800.782.4357 • www.rstahl.com# CY080113

Excellence in EngineeringLet our Houston basedengineering team help you provide a global design and solution to fit your needs. No matter where it is in the world

Web SolutionsGo to our website at

rstahl.com to learn the

latest new products and

technical information

Excellence in Customer ServiceLet our knowledgeable

customer service team

assist you in real time

Technology Solutions

LOAD

H1 H2 H3 X1 X2 X3

31 [787.40]271

2 [698.50]26 [660.40]

12 [304.80]

15 [381.00]

18 [457.20]26 [660.40]

2712 [698.50]

Ø916 [Ø14.29]

CABLE ENTRY AT BACK( KNOCK OUT NOT PROVIDED )

APPROVED GASKET MATERIAL

REMOVABLE PANEL( FRONT ACCESS )

EX

LEAD WIRE - HIGH TEMP INSULATION

FRONT VIEW

SIDE VIEW

412 [114.30]

214 [57.15]

112 [38.10]

812 [215.90]

41332 [112.01]

312 [88.90]

518 [130.00]

578 [149.05]

5 [126.95]

H0

3

42

3

42

3

421 1 1

Ex Schedule DrawingSheet 2 0f 3DWG No.3

MATERIALS:

ENCLOSURE: STEEL GAUGE # 14WALL BRACKETS: STEEL GAUGE # 12

LOAD

36732 [920.13]

322332 [831.23]

31 [787.40]

24 [609.60]32 [812.80]

34 [863.60]

APPROVED GASKET MATERIAL

REMOVABLE PANEL( FRONT ACCESS )

EX

LEAD WIRE - HIGH TEMP INSULATION

SIDE VIEW

412 [114.30]

214 [57.15]

812 [215.90]

CABLE ENTRY AT BACK( KNOCK OUT NOT PROVIDED )

41332 [112.01]

312 [88.90]

518 [130.00]

618 [155.40]

FRONT VIEW

5 [126.95]

H1 H2 H3 X1 X2 X3H0

3

4

31

42

31

42

112 [38.10]

29 [736.60]

13 [330.20]

13 [330.20]

Ex Schedule DrawingDWG No.4 Sheet 2 0f 3

MATERIALS:

ENCLOSURE: STEEL GAUGE # 14WALL BRACKETS: STEEL GAUGE # 10

LOAD

31 [787.40]271

2 [698.50]26 [660.40]

18 [457.20]21 [533.40]Ø9

16 [Ø14.29]

APPROVED GASKET MATERIAL

REMOVABLE PANEL( FRONT ACCESS )

EX

LEAD WIRE - HIGH TEMP INSULATION

SIDE VIEW

5 [127.00]

412 [114.30]

214 [57.15]

112 [38.10]

812 [215.90]

12 [304.69]

15 [381.00]

2212 [571.50]

41332 [112.01]

312 [88.90]

518 [130.00]

578 [149.05]

CABLE ENTRY AT BACK( KNOCK OUT NOT PROVIDED )

31

42

31

42

31

42

H1 H2 H3 X1 X2 X3H0

Ex Schedule DrawingDWG No.2 Sheet 2 0f 3

MATERIALS:

ENCLOSURE: STEEL GAUGE # 14WALL BRACKETS: STEEL GAUGE # 12

Typical 30 kVA

Typical 45 kVA

Typical 15 kVA