technical guide for precast prestrssed concrete · pdf filetechnical guide for precast...

24
COMMERCIAL | INDUSTRIAL | AGRICULTURAL | INSITUTIONAL TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE PLANK

Upload: tranhuong

Post on 03-Mar-2018

235 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

COMMERCIAL | INDUSTRIAL | AGRICULTURAL | INSITUTIONAL

TECHNICAL GUIDE FOR PRECAST PRESTRSSEDCONCRETE HOLLOW CORE PLANK

Page 2: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Table of ContentsIntroduction......................................... 1

Manufacturing Process ...........................1

Load Table Design Criteria .....................1

Plank Design Considerations ..............1

Fire Ratings ............................................ 2

Sound Ratings....................................... 2

Tolerances ............................................... 3

Load Tables .......................................4 - 13

Details .................................................14-21

Page 3: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc.Hollow Core PLank Technical Guide | 1

IntroductionThe purpose of this technical guide is to provide assistance in select-ing and detailing precast hollow core plank manufactured by Silverstone Precast Inc.. Additional information and standard specifications are available at silverstoneprecast.ca

The load tables presented herein are intended as a guide only. Final design is determined by our engineering department based on infor-mation presented in the final plans and specifications. To ensure the optimum selection for your application, please contact us for assistance.

Although care has been taken to provide the most accurate data possible, Silverstone Precast Inc. does not assume responsibility for errors and omissions.

The Manufacturing ProcessElematic® is a machine extruded, precast, prestressed hollow core plank.

Standard widths are 48 inches and thickness of 8,10 and 12 inches. High strength prestressing strands are cast into the planks at the spacing and location required for the given span, loading and fire cover conditions. The planks are cut to length for each project using a diamond-blade saw. After the planks are cut, they are removed from the casting beds and placed into storage.

All Elematic® materials equal or exceed the requirements of applicable ASTM specifications. The concrete mix is designed to have release strength of 3,000 psi or 3,500 psi, and a 28-day compressive strength of 5,000 psi. The prestressing strands are uncoated, seven wire, low relaxation with a minimum ultimate strength of 270 ksi.

Load Table Design CriteriaThe tables herein list allowable live loads in pounds per square foot

for uniformly distributed loading. Non-uniform loading conditions resulting from point loads, line loads, openings and cantilevers require special design consideration.

The allowable load is usually governed by the ultimate capacity of the section. As a design aid, the ultimate moment capacities in governing criterion for short spans may be the horizontal shear stress between the plank and the topping.

Allowable live loads for long-span, heavily reinforced sections are limited to loads that result in a bottom-tension stress equal to the crack-ing stress. Loads beyond this limit may result in deflections that exceed the allowable value set forth in the ACI code.

The load tables are based on a plank concrete strength of 5,000 psi. Tables for topped sections are based on a topping strength of 3,500 psi and minimum thickness of 2 inches.

Maximum spans and loads shown are not absolutes. Longer spans or heavier loads may be achieved under certain conditions or different criteria than assumed in the tables. Contact us if you need assistance.

Plank Design ConsiderationsThe following items will affect the selection of appropriate plank

sizes and should be carefully reviewed by the Architect/Engineer while developing the plans and specifications for a project:

Fire Rating

• The fire rating requirement should be clearly specified in thecontract documents.

Loading Conditions

• Specify all uniform loading requirements on structural plans.• Identify line and point loads resulting from bearing walls, masonry

walls, face brick, columns, mechanical equipment, etc.• Identify diaphragm forces and lateral loads resulting from wind or

earth pressures.• Review roof plans for vertical protrusions such as parapets, pent-

houses and adjacent buildings that could require designing forsnow drift loads.

• Plank supporting stairs require special loading considerations.• Large openings or closely spaced groups of smaller openings will

reduce the plank load carrying capacity.

Topping

• Specify whether or not concrete topping is to be composite.Composite action requires the topping to be bonded to the topsurface of the plank. Topping separated by a vapor barrier orinsulation is non-composite and must be considered asuperimposed load.

• Large cambers resulting from long spans and/or heavy loads willaffect the quantity of topping, assuming a level floor is required.Two inches of composite topping at mid span is minimal, andadditional thickness at the ends of the plank may be required tomaintain level floor elevations.

Camber

• Camber is inherent in all prestressed products. It is the result of theeccentric prestress force required to resist design loads, andcannot be designed in, out, or to an exact number. The amount ofcamber will depend upon the span, design loads and thickness ofplank. Planks stored in the yard for more than 6 weeks, usually dueto construction schedule changes, will experience more cambergrowth.

• Adjacent plank of dissimilar length, strand pattern or with openingswill have inherent camber differences.

www.silverstoneprecast.ca

Page 4: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

www.silverstoneprecast.ca

Fire RatingFire rating specifications are as important as all other design parameters.

Plank rating requirements are determined by the Architect or Engineer of Record, who is also responsible for establishing the fire rating criteria for the total project.

Three methods generally for determining hollowcore plank fire-resistive ratings are:

1. 2006 International Building Code2. Rational analysis as defined by PCI MNL 124, “Design for Fire

Resistance of Precast Concrete”3. Underwriters Laboratories Fire Resistive Ratings

International Building Code “IBC” Fire RatingThe IBC code prescribes fire ratings to any hollowcore plank section.

Since 2000, the IBC code has replaced the BOCA, SBC and UBC model codes in many states. The two criteria that are measured to determine the fire rating are:

1. Equivalent concrete thickness – 4.6" inches is required for 2 hrs2. Bottom strand cover – ¾" cover is required for 2 hrs (restrained

condition)

Underwriters Laboratories Fire Resistive RatingsPrior to codes including prescriptive fire-endurance rating methods,

fire tests provided the primary source of ratings classifications. While some plank sections were fire tested, others can be evaluated by UL to qualify for existing UL numbers.

The table below lists the UL ratings available with Elematic® plank. Note that these ratings are dependent upon whether or not the ends of the planks are restrained. Determination of the restraint must be made by the Architect or the Engineer of Record, as it is primarily a function of the support structure.

Fire Ratings by Rational AnalysisPCI MNL 124 defines the “rational analysis” method for determining

the fire rating of precast, prestressed members. It is useful when a fire rating cannot be obtained by either of the two previous methods. Actual practice has shown that this method is very conservative and that the span of the hollowcore plank will have to be reduced (approx. 10% to 20%) to achieve the same fire rating from both IBC and UL.

In using this method, the reduced strength of the prestressed strands at elevated temperatures is determined and the resulting moment capacities are compared to that required for service loads. Strand

2 | Silverstone Precast Inc. Hollow Core Plank Technical Guide

temperatures are based on the amount of concrete cover and the standard fire exposure as defined by the time-temperature relationship specified in ASTM E119. Fire ratings will also be improved if the plank assembly is restrained against thermal expansion. It should be noted that the only universally accepted definition of full restraint is an interior bay of a multi-bay building.

Sound RatingsThe following tables contain values for the Sound Transmission Class

(STC) and the Impact Insulations Class (IIC) of various floor systems utilizing Elematic® hollowcore plank.

Sound Transmission Class (STC)The values for the

Sound Transmission Class were deter-mined by tests which were in accordance with ASTM E90. The STC is a measure (in decibels) of the ease at which air-borne sound is transmit-ted through a floor system. The larger the value of the STC for a given system, the greater the sound insulation.

UL Number

Rating (Hour) PlankThickness

(inch)

ToppingThickness

(inch)Restrained Unrestrained

J994 1½ 1½ 8,10,12 0

J994 2 1½ 8,10,12 ½ Gypcrete

J994 3 1½ 8,10,12 21/8 Topping

J994 4 1½ 8, 10,12 33/8 Topping

Impact Insulation Class (IIC)

Types of Floor Systems Rating

8" Hollowcore Plank 28

8" Hollowcore Plank + ½" wood block flooring adhered directly 47

8" Hollowcore Plank + 0.058" vinyl tile 50

8" Hollowcore Plank + quarry tile w/reinforced mortar bed with 0.4" nylon and carbon black spinneret matting.

54

8" Hollowcore Plank + pad & carpet 73

Add Acoustical Ceiling +6

Sound Transmission Class (STC)

8" Elematic®

8" Elematic® + 2" Topping 54

H8" Heavy Elematic® 51

H8" Heavy Elematic® + 2" Topping 55

12" Elematic® 54

12" Elematic® + 2" Topping 57

Impact Insulation Class (IIC)

The values for the Impact Insulation Class (IIC) were determined by tests which were in accordance with ASTM ES492. The Impact Insulation Class is the resistance to impact noise transmission and is highly dependent on the floor surface and structural connection details. As with the STC, the higher IIC values are more desirable.

10" Elematic®

10" Elematic® + 2" Topping 56

52

51

Page 5: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

silverstone Precast Inc. Hollow Core plank Technical Guide | 3www.silverstoneprecast.ca

Production and Erection Tolerances: (Reprinted from PCI Manual for the Design of Hollowcore Slabs)

a = Length ..................................................................................................................................±1/2 in.b = Width ...................................................................................................................................±1/4 in.c = Depth ...................................................................................................................................±1/4 in.dt = Top flange thickness

Top flange area defined by the actual measured values of average dt x b shall not be less than 85% of the nominal area calculated by dt nominal x b nominal.

db = Bottom flange thickness Bottom flange area defined by the actual measured values of average db x b shall not be less than 85% of the nominal area calculated by db nominal x b nominal.

e = Web thickness The total cumulative web thickness defined by the actual measured value of e shall not be less than 85% of the nominal cumulative width calculated by ∑e nominal.

f = Blockout location .................................................................................................................. ±2 in.g = Flange angle ....................................................................................... 1/4 in. per 12 in., 1/2 in. maxh = Variation from specified end squareness or skew .................................................................±1/2 in.i = Sweep (variation from straight line parallel to centerline of member) ...................................±3/8 in.j = Center of gravity of strand group

The CG of the strand group relative to the top of the plank shall be within ±1/4 in. of the nominal strand group CG. The position of any individual strand shall be with ±1/2 in. of nominal vertical posi-tion and ±3/4 in. of nominal horizontal position and shall have a minimum cover of ±3/4 in.

k = Position of plates ................................................................................................................. ±2 in.l = Tipping and flushness of plates ...........................................................................................±1/4 in.m = Local smoothness ...................................................................................................±1/4 in. in 10 ft.

(does not apply to top deck surface left rough to receive a topping or to visually concealed surfaces)Plank weight: Excess concrete material in the plank internal features is within tolerance as long as the measured weight of the individual plank does not exceed 110% of the nominal published unit weight used in the load capacity calucation.n = Applications requiring close control of differential camber between adjacent membes of the same

design should be discussed in detail with the producer to determine applicable tolerances.

Product Tolerances: Hollowcore Slabs

a = Plan location from building grid datum .................................................................... ±1 in.a1 = Plan location from centerline of steel1 ...................................................................... ±1 in.b = Top elevation from nonminal elevation at member ends

Covered with topping ..............................................................................................±3/4 in.Untopped floor ........................................................................................................±1/4 in.Untopped roof .........................................................................................................±3/4 in.

c = Maximum jog in alighment of matching edges (both topped and untopped construction) ................................................................ ±1 in.

d = Joint width 0 to 40 ft. member length ........................................................................................±1/2 in.41 to 60 ft. member length ......................................................................................±3/4 in.61 ft. plus ................................................................................................................. ±1 in.

e = Differential top elevation as erected Covered with topping ................................................................................................3/4 in.Untopped floor ..........................................................................................................1/4 in.Untopped roof2 ..........................................................................................................3/4 in.

f = Bearing length3 (span direction) ..............................................................................±3/4 in.g = Differential bottom elevation of exposed hollowcore slabs4 .......................................1/4 in.

1 For precast concrete erected on a steel frame building, this tolerance takes precedence over tolerance on dimension “a”.

2 It may be necessary to feather the edges to ±1/4 in. to properly apply some roof membranes.

3 This is a setting tolerance and should not be confused with structural performance requirements set by the architect/engineer.

4 Untopped installation will require a larger tolerance here.

Erection Tolerances: Hollowcore Floor & Roof Members

Page 6: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

4 | Silverstone PRecast Inc. Hollow Core PLank Technical Guide www.silverstoneprecast.ca

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

21/3

2"1

11/3

2"2

11/3

2"6

3/32

"

1/2"

4'-0

"

7 7/

16"

7 7/

16"

7 7/

16"

7 1/

8"5 29/32" 31/32"

25/32"3 3/4"

2"5/16

"

1 31/32"1 1/2"

R3 3/16"

1 1/8"

8"

7 1/

8"7

7/16

"2"

1 3/8"5 1/8"1 1/2"

3/8"

3/8"

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

IN P

LACE

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

17pe

r Uni

t16

1514

1311

1012

*

WIT

H NO

TOP

PING

E8" x

48"

SEC

TION

Desi

gnat

ion

Stan

dard

Com

bina

tion

P/S

Stra

nd

7-W

ire27

0 Lo

lax

P/S

Area

Sq. I

n.

Stra

nd

Kip-

Ft.

oM

nM

omen

t,Be

ndin

gUl

timat

e

3332

3130

2928

2726

2524

2322

2120

1918

f'ci =

3,0

00 p

si

I = 1

,580

in.

Grou

ted

wei

ght o

f pla

nk is

54

lbs.

per

sq.

ft.

f'pu

= 27

0, 0

00 p

si

f'c =

5,0

00 p

siAr

ea =

207

in.

bw =

10.

0 in

.4

2

12.3

0

12.3

0

12.3

0

SIM

PLE

SPAN

IN F

EET

oVc

win

Kip

spe

rUn

it

204

4-7/

16"o

20_0

8704

196

0.46

058

.88

348

386

316

260

289

230

182

163

143

112

126

99

5-7/

16"o

20_0

8705

0.57

572

.52

226

446

359

398

326

275

298

254

112

182

202

164

135

148

123

103

91

6-7/

16"o

20_0

8706

0.69

085

.44

243

460

370

411

337

283

308

262

135

221

199

163

179

148

123

113

104

8696

251

6-1/

2"o

20_0

8806

473

0.91

810

9.88

381

423

347

292

317

270

135

217

234

196

162

178

148

124

105

114

8997

8312

.30

74

260

7-1/

2"o

20_0

8807

489

1.07

112

4.60

394

437

358

302

328

280

146

227

242

211

175

192

160

134

114

124

9710

590

12.3

084

78

251

7-7/

16"o

20_0

8707

473

0.80

597

.96

381

423

347

292

317

270

126

226

204

184

151

167

138

9811

610

681

9073

12.3

0

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilve

rsto

ne

Prec

ast

Inc

.Th

e ta

ble

indi

cate

s m

axim

um s

afe

load

s. C

ambe

r and

defle

ctio

n m

ust a

lway

s be

inve

stig

ated

by

the

arch

itect

,an

d/or

eng

inee

r for

the

cont

empl

ated

load

ing

and

span

so th

at th

ese

fact

ors

are

com

patib

le w

ith th

e co

ntig

uous

mat

eria

ls in

the

prop

osed

stru

ctur

e.Va

lues

to th

e le

ft an

d be

low

the

heav

y st

eppe

d lin

e ar

eco

ntro

lled

by s

hear

.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

8777

68

8171

7769

65

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

ltSi

lver

sto

ne

Prec

ast

Inc

.

Page 7: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 5ww.silverstoneprecast.ca

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

7 7/

16"

4'-0

"

21/3

2"

1 1/8"

R3 3/16"

1 1/2"1 31/32"

5/16

"

2"

3 3/4"25/32"

31/32"5 29/32" 7 1/

8"7

7/16

"

1/2"

6 3/

32"

2 11

/32"

1 11

/32"

3/8"

3/8"

1 1/2" 5 1/8" 1 3/8"

2"7

7/16

"7

1/8"

8"

7 7/

16"

2"

Grou

ted

wei

ght o

f pla

nk &

2" t

oppi

ng is

54+

25 =

79

lbs.

per

sq.

ft.

f'c =

5,0

00 p

si

f'pu

= 27

0,00

0 ps

iIc

= 3

,072

in.

f'ci =

3,0

00 p

si 4bw

= 1

0.0

in.

Area

= 2

07 in

.2

3332

3129

2830

2726

2423

2520

2119

1822

1615

1413

1110

per U

nit

1217

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

& T

OPPI

NG*

16.0

1

16.0

1

16.0

1

270

Lola

x7-

Wire

P/S

Stra

ndCo

mbi

natio

n

Stan

dard

Desi

gnat

ion

Ultim

ate

Bend

ing

Mom

ent,

Kip-

Ft.

o M

n

P/S

Stra

nd

Sq. I

n.Ar

ea

o Vc

win

Kip

sSI

MPL

E SP

AN IN

FEE

T

Unit

per

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

E8" x

48"

SEC

TION

WIT

H 2"

TOP

PING

(350

0 PS

I)

301

577

141.

8051

446

241

935

138

332

424

528

026

120

823

018

812

817

015

514

199

113

8674

16.0

1

265

243

76.2

821

343

639

533

136

130

117

923

420

513

815

711

910

083

263

248

93.7

249

540

344

533

836

828

918

823

420

915

217

013

195

112

80

301

577

126.

4051

446

241

935

238

332

523

828

026

119

321

417

415

814

312

811

197

8371

312

295

566

110.

3650

445

341

134

537

531

823

227

425

618

720

816

910

415

313

912

116

.01

9076

4-7/

16"o

20_0

8704

T0.

460

5-7/

16"o

20_0

8705

T0.

575

6-7/

16"o

20_0

8706

T0.

690

6-1/

2"o

20_0

8806

T0.

918

308

589

161.

5652

547

242

836

039

133

225

128

626

822

223

520

514

118

616

915

411

812

910

592

8016

.01

7-1/

2"o

20_0

8807

T1.

071

7-7/

16"o

20_0

8707

T0.

805

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilve

rsto

ne

PRec

ast

Inc

.Th

e ta

ble

indi

cate

s m

axim

um s

afe

load

s. C

ambe

r and

de

flect

ion

mus

t alw

ays

be in

vest

igat

ed b

y th

e ar

chite

ct,

and/

or e

ngin

eer f

or th

e co

ntem

plat

ed lo

adin

g an

d sp

an

so th

at th

ese

fact

ors

are

com

patib

le w

ith th

e co

ntig

uous

m

ater

ials

in th

e pr

opos

ed s

truct

ure.

Valu

es to

the

left

and

belo

w th

e he

avy

step

ped

line

are

cont

rolle

d by

she

ar.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

68

67

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

lt si

lver

sto

ne

Prec

ast

Inc

.

Page 8: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

6 | Silverstone Precast INc.Hollow core Plank Technical Guide www.silverstoneprecast.ca

Hea

vy

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

3/8"

3/8"

1 1/2" 5 1/8" 1 3/8"

2"

4'-0

"

7 7/

16"

1 3/8" 7 1/

8"

5 1/

2"

1 1/2"1 31/32"

3 3/4"25/32"

5/16

"

2"31/32"5 21/32"

1/2"

2 21

/32"

7 7/

16"

1 15

/16"

7 7/

16"

7 7/

16"

31/3

2"

7 1/

8"

8"

R3 15/16"

R3 15/16"

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

IN P

LACE

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

17pe

r Uni

t16

1514

1311

1012

*

WIT

H NO

TOP

PING

H8" x

48"

SEC

TION

Desi

gnat

ion

Stan

dard

Com

bina

tion

P/S

Stra

nd

7-W

ire27

0 Lo

lax

P/S

Area

Sq. I

n.

Stra

nd

Kip-

Ft.

oM

nM

omen

t,Be

ndin

gUl

timat

e

3332

3130

2928

2726

2524

2322

2120

1918

f'ci =

3,0

00 p

si

I = 1

,667

in.

Grou

ted

wei

ght o

f pla

nk is

60

lbs.

per

sq.

ft.

f'pu

= 27

0, 0

00 p

si

f'c =

5,0

00 p

siAr

ea =

230

in.

bw =

13.

77 in

.4

2

16.9

3

16.9

3

16.9

3

SIM

PLE

SPAN

IN F

EET

oVc

win

Kip

spe

rUn

it

210

4-7/

16"o

30_0

8704

222

0.46

058

.88

367

421

324

259

289

234

182

159

139

107

122

94

5-7/

16"o

30_0

8705

0.57

572

.52

257

609

461

526

408

323

364

287

111

206

230

181

142

160

126

9886

6-7/

16"o

30_0

8706

0.69

085

.44

277

633

511

566

456

350

398

310

147

249

225

186

204

165

130

116

103

8192

300

6-1/

2"o

30_0

8806

649

0.91

811

0.04

525

581

478

380

431

337

151

243

270

221

184

201

169

136

109

121

8798

7816

.93

70

322

7-1/

2"o

30_0

8807

669

1.07

112

5.32

541

599

493

407

452

361

166

261

289

237

197

215

180

153

124

138

101

112

9116

.93

8274

283

7-7/

16"o

30_0

8707

650

0.80

598

.00

525

581

466

358

406

317

136

254

229

209

172

190

153

9712

110

877

8668

16.9

3

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilve

rsto

ne

Prec

ast

Inc

.Th

e ta

ble

indi

cate

s m

axim

um s

afe

load

s. C

ambe

r and

defle

ctio

n m

ust a

lway

s be

inve

stig

ated

by

the

arch

itect

,an

d/or

eng

inee

r for

the

cont

empl

ated

load

ing

and

span

so th

at th

ese

fact

ors

are

com

patib

le w

ith th

e co

ntig

uous

mat

eria

ls in

the

prop

osed

stru

ctur

e.Va

lues

to th

e le

ft an

d be

low

the

heav

y st

eppe

d lin

e ar

eco

ntro

lled

by s

hear

.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

8373

75

72

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

ltSi

lver

sto

ne

Prec

ast

INc

.

Page 9: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast INc. Hollow core Plank Technical Guide | 7www.silverstoneprecast Inc.ca

Hea

vy

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

7 7/

16"

4'-0

"

25/32"3 3/4"

1 31/32"1 1/2"

5 1/

2"

7 1/

8"1 3/8" 5 21/32" 31/32"

2"5/16

"

2 21

/32"

1/2"

1 15

/16"

2"

1 3/8"5 1/8"1 1/2"

3/8"

7 7/

16"

31/3

2"

7 7/

16"

R3 15/16"

R3 15/16"

7 1/

8"7

7/16

"

8"

2"

3/8"

Grou

ted

wei

ght o

f pla

nk &

2" t

oppi

ng is

60+

25 =

85

lbs.

per

sq.

ft.

f'c =

5,0

00 p

si

f'pu

= 27

0,00

0 ps

iIc

= 3

,143

in.

f'ci =

3,0

00 p

si 4bw

= 1

3.77

in.

Area

= 2

30 in

.2

3332

3129

2830

2726

2423

2520

2119

1822

1615

1413

1110

per U

nit

1217

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

& T

OPPI

NG*

22.0

4

22.0

4

22.0

4

270

Lola

x7-

Wire

P/S

Stra

ndCo

mbi

natio

n

Stan

dard

Desi

gnat

ion

Ultim

ate

Bend

ing

Mom

ent,

Kip-

Ft.

o M

n

P/S

Stra

nd

Sq. I

n.Ar

ea

o Vc

win

Kip

sSI

MPL

E SP

AN IN

FEE

T

Unit

per

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

H8" x

48"

SEC

TION

WIT

H 2"

TOP

PING

(350

0 PS

I)

400

802

141.

8071

664

658

749

553

845

128

935

732

023

826

221

012

318

516

214

193

107

8068

22.0

4

266

283

76.2

823

947

241

633

137

029

917

523

120

013

315

211

293

76

298

356

93.7

667

852

459

342

046

733

719

926

122

914

617

112

488

105

376

802

126.

4071

664

658

748

053

842

327

133

530

121

424

518

616

214

112

210

590

7764

379

367

789

110.

3670

463

557

746

952

841

326

532

729

420

423

417

797

153

133

114

22.0

482

4-7/

16"o

30_0

8704

T0.

460

5-7/

16"o

30_0

8705

T0.

575

6-7/

16"o

30_0

8706

T0.

690

6-1/

2"o

30_0

8806

T0.

918

432

817

161.

6073

065

959

950

554

846

831

238

534

625

628

223

314

621

318

816

611

312

999

8674

22.0

47-

1/2"

o30

_088

07T

1.07

1

7-7/

16"o

30_0

8707

T0.

805

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilve

rsto

ne

Prec

ast

Inc

.Th

e ta

ble

indi

cate

s m

axim

um s

afe

load

s. C

ambe

r and

de

flect

ion

mus

t alw

ays

be in

vest

igat

ed b

y th

e ar

chite

ct,

and/

or e

ngin

eer f

or th

e co

ntem

plat

ed lo

adin

g an

d sp

an

so th

at th

ese

fact

ors

are

com

patib

le w

ith th

e co

ntig

uous

m

ater

ials

in th

e pr

opos

ed s

truct

ure.

Valu

es to

the

left

and

belo

w th

e he

avy

step

ped

line

are

cont

rolle

d by

she

ar.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

72

68

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

lt Si

lver

sto

ne

PRec

ast

Inc

.

Page 10: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

8| Silverstone Precast Inc. Hollow core Plank Technical Guide www.silverstoneprecast.ca

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

4 13

/32"

7 5/

8"

4'-0

"

7 1/

4"2

3/4"

1/2"

7 1/

4"1

19/3

2"

8 7/

32"

7 7/16"

5 3/4"

1 15

/16"

25/32"

1 3/16"

5/16

"

1 1/2"1 31/32"

1 3/8"7

5/8"

1 3/

16"

1 3/

16"

10 2

5/32

"8

13/1

6"

10"

1 3/8"

8 7/

32"

7 1/4"

7 5/

8"

1 3/

16"

1 3/

16"

R3 13/1

6"

1 3/8"

1 15

/16"

3/8"

3/8"

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

WIT

H NO

TOP

PING

E10"

x 4

8" S

ECTI

ON

I = 3

,080

in.

f'ci =

3,0

00 p

si

Grou

ted

wei

ght o

f pla

nk is

67

lbs.

per

sq.

ft.

f'c =

5,0

00 p

si

f'pu

= 27

0,00

0 ps

ibw

= 1

0.0

in.

Area

= 2

57 in

.4

2

240

207

22

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

IN P

LACE

20_1

0708

20_1

0706

Desi

gnat

ion

Stan

dard

*8-7/

16"o

0.92

0

6-7/

16"o

Com

bina

tion

7-W

ire27

0 Lo

lax

P/S

Stra

nd

P/S

0.69

0

Stra

nd

Sq. I

n.Ar

ea

337

318

17

147.

9239

236

3

Bend

ing

114.

12

Mom

ent,

per U

nit

Kip-

Ft.

oM

n

Ultim

ate

371

15

343

16

314

294

259

276

297

18

277

19

228

21

251

20

SIM

PLE

SPAN

IN F

EET

185

219

201

170

157

159

189

23

173

24

146

2625

135

27

125

145

134

116

108

105

30

124

28

115

2931 94

32

8593

100

77

3534

85

3336

37

16.0

1

16.0

1

oVc

w

16.0

1

in K

ips

38Un

itpe

r

253

10-7

/16"

o20

_107

1041

31.

150

179.

9635

538

333

229

131

027

487

143

213

232

196

167

180

154

115

133

123

100

107

9380

73

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilv

erst

on

e Pr

ecas

t In

c.

The

tabl

e in

dica

tes

max

imum

saf

e lo

ads.

Cam

ber a

ndde

flect

ion

mus

t alw

ays

be in

vest

igat

ed b

y th

e ar

chite

ct,

and/

or e

ngin

eer f

or th

e co

ntem

plat

ed lo

adin

g an

d sp

anso

that

thes

e fa

ctor

s ar

e co

mpa

tible

with

the

cont

iguo

usm

ater

ials

in th

e pr

opos

ed s

truct

ure.

Valu

es to

the

left

and

belo

w th

e he

avy

step

ped

line

are

cont

rolle

d by

she

ar.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

76

227

20_1

0806

6-1/

2"o

0.91

832

714

7.52

381

353

305

285

249

263

174

207

190

161

148

118

137

127

109

102

16.0

193

8476

70

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

ltSi

lver

sto

ne

Pr

ecas

t In

c.

Page 11: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 9www.silverstoneprecast.ca

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

4'-0

"

7 5/

8"

R3 13/1

6"

1 3/

16"

1 3/

16"

7 5/

8"1 3/8"

1 31/32"1 1/2"

5/16

"

1 3/16"

25/32"

1 15

/16"

5 3/4"

7 7/16" 8 7/

32"

1 19

/32"

7 1/

4"

1/2"

2 3/

4"7

1/4"

3/8"

3/8"

1 15

/16"1 3/8"

1 3/

16"

1 3/

16"

7 5/

8"

7 1/4"

8 7/

32"

1 3/8"

10"

8 13

/16"

10 2

5/32

"4

13/3

2" 2"

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

WIT

H 2"

TOP

PING

(350

0 PS

I)E1

0" x

48"

SEC

TION

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

& T

OPPI

NG

357

343

270

Lola

xP/

S St

rand

Com

bina

tion

7-W

ire

*

Stan

dard

Desi

gnat

ion

Ultim

ate

Kip-

Ft.

Mom

ent,

o M

n

per U

nit

Bend

ing

Sq. I

n.

Stra

ndAr

ea

P/S

448

384

414

431

1517 36

939

8

1618

19.7

2

19.7

2

in K

ips

o Vc

wSI

MPL

E SP

AN IN

FEE

T

293

333

312

276

260

279

21

320

19

300

2022 25

222

8

23

204

223

245

187

172

172

26

189

208

2425

27 158

141

28

9534

134

145

158

120

107

93

30 107

123

2931

793233

833536

3738

Unit

per

Grou

ted

wei

ght o

f pla

nk &

2" t

oppi

ng is

67+

25 =

92

lbs.

per

sq.

ft.

f'pu

= 27

0,00

0 ps

i

f'c =

5,0

00 p

si

Ic =

5,2

38 in

.

f'ci =

3,0

00 p

si 4bw

= 1

0.0

in.

Area

= 2

57 in

.2

19.7

228

746

539

842

937

132

434

630

516

927

125

623

820

021

818

413

315

614

411

112

399

7788

68

20_1

0708

T

20_1

0706

T

8-7/

16"o

0.92

0

6-7/

16"o

0.69

0

179.

64

138.

96

10-7

/16"

o20

_107

10T

1.15

021

8.24

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilv

erst

on

e Pr

ecas

t In

c.

The

tabl

e in

dica

tes

max

imum

saf

e lo

ads.

Cam

ber a

nd

defle

ctio

n m

ust a

lway

s be

inve

stig

ated

by

the

arch

itect

, an

d/or

eng

inee

r for

the

cont

empl

ated

load

ing

and

span

so

that

thes

e fa

ctor

s ar

e co

mpa

tible

with

the

cont

iguo

us

mat

eria

ls in

the

prop

osed

stru

ctur

e.Va

lues

to th

e le

ft an

d be

low

the

heav

y st

eppe

d lin

e ar

e co

ntro

lled

by s

hear

.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

67

350

440

376

406

287

327

306

270

253

192

210

230

176

161

120

136

148

106

20_1

0806

T6-

1/2"

o0.

918

179.

1694

8271

19.7

2

72

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

lt Si

lver

sto

ne

Pr

ecas

t In

c.

Page 12: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

10| Silverstone Precast Inc. Hollow core Plank Technical Guide www.silverstoneprecast.ca

Hea

vy

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

WIT

H NO

TOP

PING

H10"

x 4

8" S

ECTI

ON

I = 3

,080

in.

f'ci =

3,0

00 p

si

Grou

ted

wei

ght o

f pla

nk is

71

lbs.

per

sq.

ft.

f'c =

5,0

00 p

si

f'pu

= 27

0,00

0 ps

ibw

= 1

4.29

in.

Area

= 2

71 in

.4

2

273

241

22

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

IN P

LACE

30_1

0708

30_1

0706

Desi

gnat

ion

Stan

dard

*8-7/

16"o

0.92

0

6-7/

16"o

Com

bina

tion

7-W

ire27

0 Lo

lax

P/S

Stra

nd

P/S

0.69

0

Stra

nd

Sq. I

n.Ar

ea

442

389

17

147.

9255

749

5

Bend

ing

114.

12

Mom

ent,

per U

nit

Kip-

Ft.

oM

n

Ultim

ate

489

15

434

16

398

359

298

326

349

18

316

19

264

21

288

20

SIM

PLE

SPAN

IN F

EET

214

250

231

196

177

173

216

23

193

24

155

2625

139

27

132

160

145

120

109

100

30

125

28

112

2931 89

32

8189

9873

3534

79

3336

37

22.8

8

22.8

8

oVc

w

22.8

8

in K

ips

38Un

itpe

r

287

10-7

/16"

o30

_107

1058

51.

150

180.

0446

552

041

834

337

831

384

160

243

263

225

194

208

176

121

146

133

101

111

9276

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilv

erst

on

e Pr

ecas

t In

c.

The

tabl

e in

dica

tes

max

imum

saf

e lo

ads.

Cam

ber a

ndde

flect

ion

mus

t alw

ays

be in

vest

igat

ed b

y th

e ar

chite

ct,

and/

or e

ngin

eer f

or th

e co

ntem

plat

ed lo

adin

g an

d sp

anso

that

thes

e fa

ctor

s ar

e co

mpa

tible

with

the

cont

iguo

usm

ater

ials

in th

e pr

opos

ed s

truct

ure.

Valu

es to

the

left

and

belo

w th

e he

avy

step

ped

line

are

cont

rolle

d by

she

ar.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

70

260

30_1

0806

6-1/

2"o

0.91

842

114

7.52

530

470

378

342

284

310

200

239

221

180

162

120

147

133

109

9822

.88

8980

72

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

ltSi

lver

sto

ne

Pr

ecas

t IN

c.

1 15

/16"

1 15

/16"

4'-0

"

8 7/

32"

3 1/

4"

R3 15/16"

R3 11

/32"

1/2"

3/8"

11/3

2"

6 1/

4"6

1/4"

4 13

/32"

8 13

/16"

10 2

5/32

"2

9/16

"

8 7/

32"

7 5/

8"7

5/8"

7 5/

8"

1 3/

16"

1 3/

16"

1 3/

16"

1 3/

16"

25/32"

17/32" 1 3/8"

1 3/8"1 3/8" 7 1/4"

10"

3/8"

1 31/32"5 3/4"

7 3/32"

1 1/2"

Page 13: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 11www.silverstoneprecast.ca

Hea

vy

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

1 15

/16"

1 15

/16"

4'-0

"

8 7/

32"

3 1/

4"

R3 15/16"

R3 11

/32"

1/2"

3/8"

11/3

2"

6 1/

4"6

1/4"

4 13

/32"

8 13

/16"

10 2

5/32

"2

9/16

"

8 7/

32"

7 5/

8"7

5/8"

7 5/

8"

1 3/

16"

1 3/

16"

1 3/

16"

1 3/

16"

25/32"

17/32"

2"

1 3/8"

1 3/8"1 3/8" 7 1/4"

10"

3/8"

1 31/32"5 3/4"

7 3/32"

1 1/2"

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

WIT

H 2"

TOP

PING

(350

0 PS

I)H1

0" x

48"

SEC

TION

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

& T

OPPI

NG

507

442

270

Lola

xP/

S St

rand

Com

bina

tion

7-W

ire

*

Stan

dard

Desi

gnat

ion

Ultim

ate

Kip-

Ft.

Mom

ent,

o M

n

per U

nit

Bend

ing

Sq. I

n.

Stra

ndAr

ea

P/S

663

566

614

626

1517 49

355

4

1618

28.1

8

28.1

8

in K

ips

o Vc

wSI

MPL

E SP

AN IN

FEE

T

374

456

412

341

312

322

21

397

19

359

2022 28

725

7

23

235

263

285

209

187

179

26

203

230

2425

27 156

136

28

8934

131

148

166

116

103

87

30 102

118

2931

743233

773536

3738

Unit

per

Grou

ted

wei

ght o

f pla

nk &

2" t

oppi

ng is

71+

25 =

96

lbs.

per

sq.

ft.

f'pu

= 27

0,00

0 ps

i

f'c =

5,0

00 p

si

Ic =

5,3

36 in

.

f'ci =

3,0

00 p

si 4bw

= 1

4.29

in.

Area

= 2

71 in

.2

28.1

836

067

057

061

753

043

548

139

518

832

930

227

823

325

720

913

516

815

110

712

094

7383

30_1

0708

T

30_1

0706

T

8-7/

16"o

0.92

0

6-7/

16"o

0.69

0

179.

64

138.

96

10-7

/16"

o30

_107

10T

1.15

021

8.28

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilv

erst

on

e Pr

ecas

t In

c.

The

tabl

e in

dica

tes

max

imum

saf

e lo

ads.

Cam

ber a

nd

defle

ctio

n m

ust a

lway

s be

inve

stig

ated

by

the

arch

itect

, an

d/or

eng

inee

r for

the

cont

empl

ated

load

ing

and

span

so

that

thes

e fa

ctor

s ar

e co

mpa

tible

with

the

cont

iguo

us

mat

eria

ls in

the

prop

osed

stru

ctur

e.Va

lues

to th

e le

ft an

d be

low

the

heav

y st

eppe

d lin

e ar

e co

ntro

lled

by s

hear

.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

481

651

537

603

355

432

391

324

297

213

240

270

190

168

116

132

149

102

30_1

0806

T6-

1/2"

o0.

918

179.

1689

7628

.18

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

lt Si

lver

sto

ne

Pr

ecas

t in

c.

Page 14: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

12 | Silverstone Precast Inc. Hollow core Plank Technical Guide www.silverstoneprecast.ca

oM

n

ELEM

ATIC

® Ho

llo

w c

or

e P

lan

k

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

WIT

H NO

TOP

PING

N12"

x 4

8" S

ECTI

ON

I = 5

,246

in.

f'ci =

3,0

00 p

siGr

oute

d w

eigh

t of p

lank

is 8

0 lb

s. p

er s

q. ft

.f'c

= 5

,000

psi

f'pu

= 27

0,00

0 ps

ibw

= 1

4.25

in.

Area

= 3

07 in

.4

2

248

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

IN P

LACE

Ultim

ate

Kip-

Ft.

Mom

ent,

142.

08

per U

nit

Bend

ing

*

270

Lola

xP/

S St

rand

Com

bina

tion

6-7/

16"o

7-W

ireSt

anda

rdDe

sign

atio

n

20_1

2706

0.69

0

Area

Sq. I

n.

Stra

ndP/

S

377

343

276

307

SIM

PLE

SPAN

IN F

EET

184

20

224

21

203

23

167

2224

151

2725

137

26

125

2829

3231

3033

34Un

itpe

r

28.1

0

in K

ips

oVc

w

3635

286

320

7-7/

16"o

20_1

2707

20_1

2709

164.

52

206.

92

0.80

5

1.03

545

1

403

337

377

412

367

346

311

151

187

244

274

295

266

256

222

183

223

238

202

205

166

144

172

138

157

125

113

92 121

132

102

111

9310

285

28.1

0

28.1

0

3738

3940

4142

329

20_1

2808

240.

201.

224

424

464

388

357

198

282

304

262

228

245

213

153

181

167

129

141

119

100

109

9228

.10

7785

20_1

2708

8-7/

16"o

186.

080.

920

390

427

328

357

303

224

260

281

243

204

186

170

118

142

155

129

108

28.1

0

20_1

2807

213.

201.

071

399

437

336

365

310

9523

126

728

724

721

217

719

412

514

916

213

611

410

479

8728

.10

113

103

9889

72

9-7/

16"o

7-1/

2"o

8-1/

2"o

5.4.3.2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

ltSi

lver

sto

ne

Prec

ast

Inc

.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilve

rsto

ne

Prec

ast

Inc

.Th

e ta

ble

indi

cate

s m

axim

um s

afe

load

s. C

ambe

r and

defle

ctio

n m

ust a

lway

s be

inve

stig

ated

by

the

arch

itect

,an

d/or

eng

inee

r for

the

cont

empl

ated

load

ing

and

span

so th

at th

ese

fact

ors

are

com

patib

le w

ith th

e co

ntig

uous

mat

eria

ls in

the

prop

osed

stru

ctur

e.Va

lues

to th

e le

ft an

d be

low

the

heav

y st

eppe

d lin

e ar

eco

ntro

lled

by s

hear

.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

4344

45

9485

76

8375

8173

7870 65

7165

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

3/8"

3/8"

1 3/8"9 1/16"1 9/16"

1 15

/16"

4'-0

"

R4 29/32"

11 1

/8"

8 19

/32"

25/32"

1/2"

7 3/4"

9 17/32"

3 13

/16"

1 3/16" 10 2

9/32

"1

15/1

6"1 5/16"

7 3/

4"

1 1/2"1 31/32"

5/16

"

2 9/

16"

11 1

/8"

1"1"

10 2

9/32

"

1 1/2"

4 9/

32"

11 1

/8"

4 9/

32"

2 5/

16"

3 17

/32"

4 7/

32"

1'-0"

1'-0

7/8

"

Page 15: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 13www.silverstoneprecast.ca

ELEM

ATIC

® H

oll

ow

co

re

Pla

nk

o M

n

8-1/

2"o

UNIF

ORM

LY D

ISTR

IBUT

ED S

UPER

IMPO

SED*

LOA

D IN

LBS

. PER

SQ.

FT.

WIT

H 2"

TOP

PING

(350

0 PS

I)N1

2" x

48"

SEC

TION

INCL

UDES

THE

LIV

E LO

AD P

LUS

ANY

DEAD

LOA

D TH

AT IS

ADD

ITIO

NAL

TO T

HE W

EIGH

T OF

THE

BAR

E GR

OUTE

D PL

ANKS

& T

OPPI

NG

284

362

340

P/S

Stra

ndCo

mbi

natio

n

270

Lola

x

*

Desi

gnat

ion

Stan

dard

7-W

ireM

omen

t,Be

ndin

g

Area

Sq. I

n.

Stra

ndP/

S

Kip-

Ft.

per U

nit

Ultim

ate

20 519

487

444

21 395

472

444

23 395

371

317

22 353

431

404

2445

SIM

PLE

SPAN

IN F

EET

27 208

286

252

25 256

334

307

26 231

310

278

28 259

229

188

29 170

233

206

32 120

146

170

136

164

189

30 154

210

184

3133 12

9

104

153

34 90 114

137

40

95

36 87 108

35 100

122

3738 83

3941

4243

44

per

Unit

33.3

9

o Vc

win

Kip

s

Grou

ted

wei

ght o

f pla

nk &

2" t

oppi

ng is

80+

25 =

105

lbs.

per

sq.

ft.

f'c =

5,0

00 p

si

f'pu

= 27

0,00

0 ps

i

f'ci =

3,0

00 p

si

Ic =

8,3

93 in

.4

Area

= 3

07 in

.

bw =

14.

25 in

.2

290

271

484

515

567

532

431

404

471

441

396

371

316

337

365

343

312

293

131

153

270

245

249

226

221

199

186

162

205

180

169

146

93 112

138

118

124

105

70 9010

1

81

8061

6170

280.

00

248.

92

192.

96

217.

56

167.

28

281

500

241.

6455

041

845

638

432

735

430

214

125

923

421

217

319

215

610

112

711

478

89

33.3

9

33.3

9

33.3

9

33.3

9

33.3

9

6-7/

16"o

8-7/

16"o

7-7/

16"o

20_1

2706

T

20_1

2707

T

20_1

2708

T

0.69

0

0.92

0

0.80

5

20_1

2709

T9-

7/16

"o1.

035

7-1/

2"o

20_1

2807

T

20_1

2808

T

1.07

1

1.22

4

5.4.3.Fo

r lon

ger s

pans

, hea

vier

load

s, o

r spe

cial

con

ditio

ns,

cons

ult S

ilve

rsto

ne

Prec

ast

Inc

.Th

e ta

ble

indi

cate

s m

axim

um s

afe

load

s. C

ambe

r and

de

flect

ion

mus

t alw

ays

be in

vest

igat

ed b

y th

e ar

chite

ct,

and/

or e

ngin

eer f

or th

e co

ntem

plat

ed lo

adin

g an

d sp

an

so th

at th

ese

fact

ors

are

com

patib

le w

ith th

e co

ntig

uous

mat

eria

ls in

the

prop

osed

stru

ctur

e.Va

lues

to th

e le

ft an

d be

low

the

heav

y st

eppe

d lin

e ar

e co

ntro

lled

by s

hear

.

NOTE

S

6.Sh

aded

regi

on in

dica

tes

expe

cted

cam

ber g

reat

er th

an 1

".

78

75

72

1.De

sign

Sta

ndar

d: A

CI 3

18-2

005

2.Fo

r com

plet

e an

d de

taile

d ca

lcul

atio

ns c

onsu

ltSi

lver

sto

ne

PRec

ast

Inc

.

3/8"

3/8"

1 3/8"9 1/16"1 9/16"

1 15

/16"

4'-0

"

R4 29/32"

11 1

/8"

8 19

/32"

25/32"

1/2"

7 3/4"

9 17/32"

3 13

/16"

1 3/16" 10 2

9/32

"1

15/1

6"1 5/16"

7 3/

4"

1 1/2"1 31/32"

5/16

"

2 9/

16"

11 1

/8"

1"1"

10 2

9/32

"

1 1/2"

4 9/

32"

11 1

/8"

4 9/

32"

2 5/

16"

3 17

/32"

4 7/

32"

1'-0"

1'-0

7/8

"

2"

Page 16: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

14 | Silverstone Precast INc. Hollow core Plank Technical Guide www.silverstoneprecast.ca

(VARIES WITH BLDG LAYOUT)1" MIN. LAP RECOMMENDED

10"

6" 6"

COURSE SOLIDFILL TOP

EXT. FIN.

PERIMETER 1:3 GROUT

LONGITUDINAL BARAS REQUIRED

#4 U-BAR GROUTED INTO POCKET @ 4'-0" O/CPLANK CAMBERHIDDEN BY FINISH MATERIALS

WALL REINFORCING

FORM ASREQ’D

#4 U-BAR GROUTED INTOPOCKET @ 4'-0" O/C

SIMILAR 1" MIN. LAP RECOMMENDED

VARIES

6" 6"

COURSE SOLIDFILL TOP

PLANK CAMBERHIDDEN BY FINISH MATERIALS

WALL REINFORCING

LONGITUDINAL BARAS REQUIRED

BUTT JOINT 1:3 GROUT

#4 BENT BAR

KEYWAYGROUTED INTO

1" MIN. LAP RECOMMENDED

3'-0"

8"

1/8"x2" KOROLATHBRG PAD

FILL TOPCOURSE SOLID

3" BRG FOR 8" CMU3 1/2" BRG FOR 10" CMU 4 1/2" BRG FOR 12" CMU

PLANK CAMBERHIDDEN BY FINISH MATERIALS

LONGITUDINAL BARAS REQUIRED

BUTT JOINT 1:3 GROUT

#4 X 4'-0" TIE ROD GROUTEDINTO KEYWAY

LONGITUDINAL BARAS REQUIRED

3 1/2" BRG FOR 10" CMU4 1/2" BRG FOR 12" CMU

3" BRG FOR 8" CMUSIMILAR

BUTT JOINT 1:3 GROUT

1/8"x2" KOROLATHBRG PAD

1/8"x2" KOROLATHBRG PAD

WALL REINFORCING COURSE SOLIDFILL TOP

2'-0"

3" BRG

INTO KEYWAY#4 BENT BAR GROUTED

8"

EXT. FIN.

PERIMETER 1:3 GROUT

LONGITUDINAL BARAS REQUIRED

COURSE SOLIDFILL TOP

NOT BY OBS

1/8"x2" KOROLATHBRG PAD

WALL REINFORCING (1/2" CLR FROM PLANK BRG)

FORM ASREQ’D

REFER TO AN-1.0 REGARDINGBRICK RELIEVING ANGLE DETAILS

COURSE SOLIDFILL TOP

FORM AS

PERIMETER 1:3 GROUT

3" BRG

1/8"x2" KOROLATHBRG PAD

WALL REINFORCING (1/2" CLR FROM PLANK BRG)

#4 BENT BAR GROUTEDINTO KEYWAY

LONGITUDINAL BARAS REQUIRED

2'-0

"

2'-0"

REQ’D

EXT. FIN.

REFER TO AN-1.0 REGARDINGBRICK RELIEVING ANGLE DETAILS

Hollow core Plank Details

E1.0 Exterior Bearing (Typ. Flr.) E2.0 Exterior Bearing (Roof)

E3.0 Interior Bearing E4.0 Exterior Side Lap

E5.0 Interior Shear Wall E6.0 Interior Change of Direction

Page 17: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 15www.silverstoneprecast.ca

6'-0

" MAX

.

10'-0

" MAX

.4'-0

"

ADJ. PLANK

PC SOLID SLAB W/ INTEGRAL SIDE BALCONY

L/2 MAX.

L

PLAN VIEW

BRG

WAL

L

BRG

WAL

L

1/4:

12 P

ITCH

SEE U-BAR DETAILPER SECTION 9

COURSE SOLIDFILL TOP

1'-4" MAX

POCKETS @ 4'-0" O/C#4 U-BAR GROUTED INTO

#4 X 1'-0" DOWELDRILL & GROUT AFTERPLANK ERECTION @ 8'-0" O.C.

1'-0"

6" 6"

ROOFING MATERIAL NOT SHOWN FOR CLARITY

PLANK CAMBERHIDDEN BY FINISH MATERIALS

T+2"

T

1/8"x2" KOROLATHBRG PAD

FILL TOPCOURSE SOLID

CANTILEVER LENGTH VARIES

3" BRG

WELDED CONNECTION

PC SOLIDAT CONNECTIONS

PC SOLID BALCONY SLABWITH 1/4" IN 12" PITCH

DRIP EDGE

5'-0" MAX. FOR T = 4"6'-0" MAX. FOR T = 6"7'-0" MAX. FOR T = 8"

STEEL SHIM IF REQ’D

TEMP. SHORING IF REQ’D

STANDARD TWO EAR HEADER

ONE EAR HEADERTHIS END SUPPORTEDON CMU BRG WALL

PLANK THK HEADER ANGLE EAR PLATE

ELEMATIC 8" L 6"x4"x3/8" PLT 4"x1/2" X 1'-1"ELEMATIC 10" L 7"x4"x1/2" PLT 4"x5/8" X 1'-1"ELEMATIC 12" L 8"x4"x1/2" PLT 4"x3/4" X 1'-1"

(RECESS FOR ANGLE THK)

1/8"x2" KOROLATHBRG PAD

CANTILEVER LENGTH VARIES

FILL TOPCOURSE SOLID

#4 X 1'-0" DOWELDRILL & GROUT IN KEYWAYS@48" O/C AFTER PLANK ERECTION

BAY WINDOW WALLEXTERIOR FINISH TOBYPASS PLANK END

INSULATION BY OTHERS TOP REINFORCING

PLK

4'-0" MAX. FOR 8" PLANK5'-0" MAX. FOR 10" PLANK

6'-0" MAX. FOR 12" PLANK

3'-0

" TO

5'-0

" (NT

S)

PLAN VIEW

STEEL HEADER

GROUT SOLID CORE IF REQ’D.

A

SECT A

HEADER ANGLE

1"

Hollowcore Plank Details

E7.0 Header Support at Large Opening E8.0 Plank Header Types

E9.0 Small Side Plank Roof Overhang E10.0 Cantilever Plank for Bay Windows

E11.0 Cantilever Solid Slab Balconies E12.0 Side Cantilever Balconies

Page 18: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

16 | Silverstone Precast Inc. Hollow core Plank Technical Guide www.silverstoneprecast.ca

#4 X 4'-0" TIE RODGROUTED INTO KEYWAY

LC

2" JT. FOR 1/2" THK ANGLES3" JT. FOR 3/4" THK ANGLES

BUTT JOINT 1:3 GROUT

4" MIN. ANGLE LEG

MAX CAMBER AT MIDSPANJUMPER PLATES AS REQ'D

LC

VARIES1'-0" MAX. @ 8'-0" O/C

SIDE WELD PLATES

3/16" 3"

3/16" 3"

#4 BENT BAR

KEYWAYGROUTED INTO

3'-0"

8" LC

1" PASS

1/2" MIN. LAP

BUTT JOINT 1:3 GROUT

PLANK CAMBERHIDDEN BY FINISH MATERIALS

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

2 1/2" MIN. BRG

7" MINRECOMMENDED

#4 X 4'-0" TIE ROD GROUTED

LC

1"1"

INTO KEYWAY

IF RESTRAINT IS EXCESSIVE. WELDING ALTERNATINGNOTE: DO NOT WELD BOTH ENDS OF THE SAME PLANK

PLANKS WILL STILL PROVIDE LATERAL BEAM BRACING.

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

LONGITUDINAL BARAS REQUIRED

BUTT JOINT 1:3 GROUT

LC

@ 8'-0" O/CSIDE WELD PLATES

MAX CAMBER AT MIDSPANJUMPER PLATES AS REQ'D

3/16" 3"

3/16" 3"

LC

1" PASS

IF RESTRAINT IS EXCESSIVE. WELDING ALTERNATINGNOTE: DO NOT WELD BOTH ENDS OF THE SAME PLANK

PLANKS WILL STILL PROVIDE LATERAL BEAM BRACING.

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

Hollow core Plank Details

E13.0 End Bearing on Steel E14.0 Interior Bearing on Steel

E15.0 Exterior Side Lap on Steel E16.0 Interior Side Lap on Steel

E17.0 Interior Change of Direction E18.0 Angle Support at Corridors

Page 19: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 17www.silverstoneprecast.ca

CANTILEVER LENGTH VARIES

BAY WINDOW WALLEXTERIOR FINISH TOBYPASS PLANK END

INSULATION BY OTHERS

TOP REINFORCING

PLK

LC

4'-0" MAX. FOR 8" PLANK5'-0" MAX. FOR 10" PLANK

6'-0" MAX. FOR 12" PLANK

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

BUTT JOINT 1:3 GROUT

#4 BENT BAR

KEYWAYGROUTED INTO

LONGITUDINAL BARAS REQUIRED

3'-0"8" LC

1" CLR FOR 1/2" THK ANGLES1 1/2" CLR FOR 3/4" THK ANGLES

1/2" MIN. LAP

4" MIN. ANGLE LEG

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

PLANK CAMBERHIDDEN BY FINISH MATERIALS

IF RESTRAINT IS EXCESSIVE. WELDING ALTERNATINGNOTE: DO NOT WELD BOTH ENDS OF THE SAME PLANK

PLANKS WILL STILL PROVIDE LATERAL BEAM BRACING.

LC

1" CLR1" CLR

BUTT JOINT 1:3 GROUT

ANGLES OR PLATESWITH STIFFENERS NOT BY OBS

2" C

OV.

2 1/2"2 1/2"

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

IF RESTRAINT IS EXCESSIVE. WELDING ALTERNATINGNOTE: DO NOT WELD BOTH ENDS OF THE SAME PLANK

PLANKS WILL STILL PROVIDE LATERAL BEAM BRACING.

GROUT SOLID

LC

7" MIN.

1" CLR1 1/4" CLR MIN. FOR ERECTION

AT BOTH ENDS OF PLANK.NOTE: DO NOT USE THIS DETAIL

(FLG INTERFERES WITH ERECTION)

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

1" CLR1" CLR

LC BUTT JOINT 1:3 GROUT

1 5/

8" C

OV.

1'-2"CONT. BOT. PLT 14"x3/8" #4 X 4'-0" TIE ROD

GROUTED INTO KEYWAY

IF RESTRAINT IS EXCESSIVE. WELDING ALTERNATINGNOTE: DO NOT WELD BOTH ENDS OF THE SAME PLANK

PLANKS WILL STILL PROVIDE LATERAL BEAM BRACING.

1" CLR

4"

1" CLR

4"

LCBUTT JOINT 1:3 GROUT

2" C

OV.

ANGLES OR PLATESWITH STIFFENERS

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

FORMING

Hollow core Plank Details

E19.0 Change of Direction on Angles E20.0 End Bearing on Upset Steel

E21.0 Interior Bearing on Upset Steel (1) E22.0 Interior Bearing on Upset Steel (2)

E23.0 Interior Bearing on Upset Steel (3) E24.0 Cantilever Plank for Bay Windows

Page 20: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

18| Silverstone Precast Inc. Hollow core Plank Technical Guide www.silverstoneprecast.ca

6"

BUTT JOINT 1:3 GROUT

#4 X 4'-0" TIE ROD GROUTEDINTO KEYWAY

1"

2 1/2" BRG2 1/2" BRG

TOP FINGER SLOTSIN PLANKS FORGROUT ACCESS

(1) WELD PLATE@ 4'-0" O.C.

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"3/16" 3"

8" MIN.GROUT

8" MIN.GROUT

DB8 GIRDER#4 X 2'-0"@ 2'-0" O.C.

FACTORY SLOTSFOR GROUT ACCESS4"AT EACH CORE

4000 PSI GROUTCONT. ALONG DB8

3" BRG(2" MIN.)

(1) WELD PLATE@ 4'-0" O.C.

8"

(1) WELD PLATE@ 4'-0" O.C.

BUTT JOINT 1:3 GROUT

#4 X 4'-0" TIE ROD GROUTEDINTO KEYWAY

2"

3" BRG 3" BRG

3/16" 3"3/16" 3"

(LOAD BEARING)CFS METAL WALL

6"

FORM AS REQ’D

1 1/2"

(1) WELD PLATE@ 4'-0" O.C.

BUTT JOINT 1:3 GROUT

3 1/2"BRG

1"

3/16" 3"

SMALL CORE

BENT PLATE OR ANGLE FIELD

INSTALLED ANCHOR

(NONLOAD BEARING)CFS METAL WALL

4" OR 6" CFS METAL WALL

4" OR 6" CFS METAL WALL

(NONLOAD BEARING)CFS METAL WALL

FIELD INSTALLED ANCHOR

SMALL CORE

FIELD INSTALLED ANCHOR

SHIMMING OF METAL STUDS REQ’DTO ADJUST FOR PLANK CAMBER

Hollow core Plank Details

E29.0 Interior Bearing on 6" Metal Wall E30.0 Typ. Girder-Slab System

E25.0 Exterior Bearing on Metal Stud E26.0 Exterior Bypass Side on Metal Stud

E27.0 Exterior Side Lap on Metal Stud E28.0 Interior Bearing on 8" Metal Wall

Page 21: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 19www.silverstoneprecast.ca

8" T

HKM

ID-L

ANDI

NG

2" CLR

L 5"x5"x1/2" X MID-LANDING WIDTH

EMBED PLT 6"x4"x3/8"

5"

FILL CMU SOLID

FILL WITH 1:3 GROUT

HILTI 3/4"Ø HAS

6 3/4" EMBED.

SPCG 8" SOLID LANDING

3/16" 3"

CAULKING B.O.

SHIM AS REQUIREDBY ERECTOR

#5 X 11" (2 PER STAIR)DRILLED & GROUTED INTOFLOOR SLAB BY ERECTOR

CIP FLOOR SLAB

1:3 GROUTBY ERECTOR

5"

2" DIA. SLEEVE CASTBY OBS

WALL REINF. B.O.

2" LAP

LAND

ING

THK

TO M

ATCH

PLK

8" SOLID LANDING

FLOOR LANDING

1" CLR

8" TY

P

8" SOLID LANDING

MID-LANDING

5 1/

2"1/

2"

GROUT BY ERECTOR

SHIM AS REQUIREDBY ERECTOR

8"

2"

5 1/2" THROAT AT HALF FLIGHT7" THROAT AT FULL FLIGHT

6"

SOLI

DLN

DG

1/8"x2" KOROLATHBRG PAD

WALL REINF. B.O.

3 1/2" BRG FOR 10" CMU4 1/2" BRG FOR 12" CMU

3" BRG FOR 8" CMU

LAND

ING

THK

TO M

ATCH

PLK

8" SOLID LANDING

5 1/2" THROATAT HALF FLIGHT

7" THROATAT FULL FLIGHT

GROUT BYERECTOR

8" S

OLID

LND

G

SHIM AS REQUIRED

1/2" 4"

3 3/

4"

4 1/2"

0"

1/2"

3 3/

4"

Hollow core Plank Details

E31.0 Precast Stair Landing & Stair Down E32.0 Precast Stair Landing & Stair Up

E35.0 Floor & Mid-Landing Back Side Lap E36.0 Mid-Landing Support Angle

E33.0 Precast Stair at Ground Slab E34.0 Floor Landing End Bearing

Page 22: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

Silverstone Precast Inc. Hollow core Plank Technical Guide | 20www.silverstoneprecast.ca

LC

CANT. AS REQ’D

(1) WELD PLATE@ 4'-0" O.C.

3/16" 3"

DAP AS REQ’D

DAP

AS R

EQ’D

SOLID END

ELEVATOR SHAFT

ELEVATOR SHAFT

PERIMETER 1:3 GROUT

LONGITUDINAL BARAS REQUIRED

COURSE SOLIDFILL TOP

WALL REINFORCING

FORM ASREQ’D

2" O

RAS

REQ

’D

SHELF ANGLE

ELEVATOR SHAFT

PLANK CAMBERHIDDEN BY FINISH MATERIALS

POCKET @ 4'-0" O/C

12"

#4 U-BAR GROUTED INTO

6"

(VARIES WITH BLDG LAYOUT)1" MIN. LAP RECOMMENDED

6"

LC

DAP AS REQ’DDA

PAS

REQ

’D

SMALL CORE

ELEVATOR SHAFT

ELEVATOR SHAFT

CANT. AS REQ’D

MAX CAMBER AT MIDSPANJUMPER PLATES AS REQ’D

3/16" 3"

3/16" 3"

@ 8'-0" O/CSIDE WELD PLATES

2'-0"

3" BRG

INTO KEYWAY#4 BENT BAR GROUTED

8"

PERIMETER 1:3 GROUT

LONGITUDINAL BARAS REQUIRED

COURSE SOLIDFILL TOP

1/8"x2" KOROLATHBRG PAD

WALL REINFORCING (1/2" CLR FROM PLANK BRG)

FORM ASREQ’D

2" O

RAS

REQ

’D

SHELF ANGLE

ELEVATOR SHAFT

FLARE TOPOF CIP WALL

FORM AS

PERIMETER 1:3 GROUT

3" BRG

1/8"x2" KOROLATHBRG PAD

WALL REINFORCING (1/2" CLR FROM PLANK BRG)

#4 BENT BAR GROUTEDINTO KEYWAY

LONGITUDINAL BARAS REQUIRED

2'-0

"

2'-0"

REQ’D

6"

(LOAD BEARING)CFS METAL WALL

6"

(1) BOTTOM WELD PLATE@ 4'-0" O.C. BY OBS

TOP PLATE 6"x3/8"x1'-0"CAST-IN PLANK

VARIES

L 8"x4"x1/2" X0'-8"SET BY ELEV. INSTALLER 1/4"

ELEVATORGUIDE RAIL

3/16" 3"

Hollow core Plank Details

E37.0 Elevator Door Support Detail (1) E38.0 Elevator Door Support Detail (2)

E39.0 Elevator Door Support Detail (3) E40.0 Elevator Door Support Detail (4)

E41.0 Elevator Stud & Plank at Elevator Wall E42.0 Exterior Bearing on 6" ICF Wall

Page 23: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

21 | Silverstone Precast Inc. Hollow core Plank Technical Guide www.silverstoneprecast.ca

PLANK

SILVERSTONE PRECAST INC. DOES NOT SUPPLY OR INSTALL BRICK RELIEVING ANGLES.

IF GROUT AND INSTALLION OF PLANK IS TO BE PERFORMED BY SILVERSTONE PRECAST THEN THE CONTRACTOR IS TO REFRAIN FROM INSTALLING BRICK RELIEVING ANGLES UNTILL THE WORK HAS BEEN COMPLETED. ESPECIALLY IN SITUATIONS WHERE THE ANGLE WOULD HINDER SILVERSTONE PRECAST FROM PERFORMING THE AGREED UPON SCOPE OF WORK.

ALL BRICK RELIEVING ANGLES SHOULD BE ANCHORED INTO THE WALL SYSTEM (SEE SECTIONS BELOW), WHICH HAS BEEN DESIGNED TO ACCOUNT FOR SUCH LOADING. DO NOT INSTALL RELIEVING ANGLES INTO GROUT OR ATTACH DIRECTLY TO THE HOLLOWCORE (PLANK).

IF YOU NEED ADDITIONAL INFORMATION OR ASSISTANCE PLEASE CONTACT SILVERSTONE PRECAST INC.

RELIEVING ANGLE

TYPICAL FOR CONCRETE WALL

PLANK

RELIEVING ANGLE

TYPICAL FOR METAL STUD

PERIMETER 1:3 GROUT

3" BRG

1/8"x2" KOROLATHBRG PAD

WALL REINFORCING (1/2" CLR FROM PLANK BRG)

#4 BENT BAR GROUTEDINTO KEYWAY

LONGITUDINAL BARAS REQUIRED

2'-0

"

2'-0"

FORM ASREQ’D

8"

#4 X 4'-0" TIE ROD GROUTEDINTO KEYWAY

LONGITUDINAL BARAS REQUIRED

BUTT JOINT 1:3 GROUT

1/8"x2" KOROLATHBRG PAD

1/8"x2" KOROLATHBRG PAD

WALL REINFORCING

8"

3" BRG 3" BRG

#4 X 4'-0" TIE ROD GROUTEDINTO KEYWAY

LONGITUDINAL BARAS REQUIRED

1/8"x2" KOROLATHBRG PAD

BUTT JOINT 1:3 GROUT

1/8"x2" KOROLATHBRG PAD

6"

WALL REINFORCING

3" BRG3" BRG

FLARE TOPOF CIP WALL

Hollow core Plank Details

E45.0 Interior Bearing on 8" ICF Wall

E44.0 Exterior Bearing on 8" ICF Wall

E43.0 Interior Bearing on 6" ICF Wall

AN-1.0 Brick Relieving Angle

Page 24: TECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE · PDF fileTECHNICAL GUIDE FOR PRECAST PRESTRSSED CONCRETE HOLLOW CORE ... “Design for Fire Resistance of Precast Concrete ... the

We Would Love To Hear From You

1.780.349.2185 | [email protected] | SilverstonePrecast.ca |

NPCA is a trademark of National Precast Concrete Association and is used with permission. Use of the NPCA trademark does not evidence an endorsement of any product by the National Precast Concrete Association.